You are on page 1of 5

Construction of Earth Quake Resistant Buildings: From Code to Practice

October 13 – 16, 2008


Banda Aceh, Indonesia

Work Group II – Site Visit (Module 3: Construction Problems on Site)

Check List for Site Inspection


(IMPLEMENTATION PROCESS OF CONSTRUCTION PROCEDURES)

I. General

S. No Description Observation on Site Note


1. Not required A B C D
2. The use of observed □ Residential
building for
□ Business
□ Others (Public Clinic)
3. Building Foundation 50 M^2
Size in m2
4. Number of floor of One floor
the observed building
5. Total height of the Approximately 5 m
observed building
6. Type of soil on Average soil (medium)
foundation
7. Soil strength for Secure enough
safety use
8. Concrete quality used Data Plan of K225 cannot be
for: measure on site, testing is
i) foundation unavailable.
ii) column
iii) Tie beam
iv) Beam/plate
S. No Description Observation on Site Note
9. Steel Reinforce Data plan is U39, but the fact
Quality there is no testing made
available on site

10 Is the building □ Neighbour house is brittle


constructed on
unstable soil?
□ Effect from demolished
If yes, what will be building
the risk? □ No access, it is predicted the
soil is quite stable
11. Security problems on □ Material placement
site?
□ Public safety is applied Material
□ Hazard materials like placement does
reinforce steel and nail are not follow
spread around procedure

12. Structure system of □ RCC frame structure RCC frame


the observed building structure
□ Load bearing wall system
□ Other (explain….)
II. Materials

S. No Description Observation on Site Note


1. Sand:
Retention of water Average, depending on weather,
there was no water during
observation

General quality Visually, sand contains mud

2. Brick:
Quality Average
Cleanness Good
Water absorbance None
3. Cement:
Storage Stored in a covered place, bed
with plywood

Purchase date Unknown

4. Aggregate:
Gradation Good
Cleanness Average
Shape Available in split and round

5. Steel Reinforce:
Quality Good
Condition & corrosion Corrosion to some part of it
Physical shape Good enough
III. Construction

S. No Description Observation on Site Note


1.

2.
3.

IV. For RCC Frame Structure

S. No Description Observation on Site Note


1.

2.
3.

4.
5.
6.
7.
8.