Note: The Ohmmeter Test can be performed on Set the ohmmeter on the scale that reads approxi-
Membrane Control Models ONLY. Glass Touch mately 500 Ω. Connect leads to the ribbon cable
Models should read infinitely high resistance as indicated in the chart for each function. De-
between ALL pins. press the function pad. Meter should read less
than infinity ohms if the switch contact is working.
If some of the pads work and some don’t, the
problem is probably the key panel. To verify that Note: See special instructions for Glass Touch
the key panel is the problem, perform the Ohmme- Models, page 25.
ter Test. If the ohmmeter reads infinite ohms when
depressing the pad, or shows less than 1 MEG Note: Replacement touch pads come as part of
OHM without depressing the pad, the key panel is the control panel.
bad. The ohmmeter should read under 300 Ω Note: Conductors are not all on the same side.
when pressing a pad.
– 23 –
For more help, see Samurai Appliance Repair Man at www.FixitNow.com.