Professional Documents
Culture Documents
www.huawei.com
Foreword
The OptiX RTN 600 radio transmission system is a split-mount digital microwave transmission system developed by Huawei The maximum microwave transmission capacity are 2 STM-1s. The OptiX RTN 600 provides various service interfaces and features flexible configuration and easy installation. The OptiX RTN 600 can construct a radio transmission network that serves as backhaul links for mobile communication networks or private networks. The OptiX RTN 600 can also construct a hybrid network that is used to transmit SDH, PDH, and Ethernet services together with the OptiX series optical transmission products of Huawei.
Page1
Objectives
Describe the main characteristics of OptiX RTN 600. Describe the system structure and software and hardware
List the types and features of the IDU List the functions of boards in the IDU, ODU, Hybrid coupler and
antenna
Page2
Contents
1. Equipment Overview 2. Equipment Structure
Page3
Contents
1. Equipment Overview
1.1 Equipment Components
Hybrid coupler
Page4
Equipment Components
Antenna
Hybrid Coupler IF Cable
Page5
IF Cable
ODU
Pole
IDU
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved. Page6
IDU
IDU 610
IDU 620
Page7
IDU (Cont.)
consists 5 models
IDU 605 1A: providing 5 E1s IDU 605 1B: providing 16 E1s
IDU 605 1B
IDU 605 2B
Page8
IDU (Cont.)
3xFE+1xGE/FE and 11
microwave protection
IDU 605 1F
IDU 605 2F
Page9
IF Cable
1/2 inch and RG-8U cable: connection between ODU and IF jumper.
RG-8U cable is used for the distance less than 180 meter. 1/2 inch cable is used for the distance between 180m and 300m.
IF jumper
IF cable
Page10
ODU
The ODU in OptiX RTN 600 can support capacity from 2 E1s to
one STM-1.
Page11
Hybrid Coupler
When two ODUs share one antenna, the ODUs must be connected to an RF signal coupler/ splitter (hybrid coupler). Then,
Page12
Antenna
Page13
Page14
Page15
Equipment Characteristics
PDH/SDH integrated microwave transmission system. The modulation mode and link capacity are set by software.
Microwave link supports the SNCP. Built-in ADM provides flexible service add/drop function.
Providing the clock tracing, XPIC, MW N+1, REG and RMSP functions.
Synchronous data interface and Orderwire spanning (for Ver. C SCC) Supporting removable FLASH card.
Supporting AM and Hybrid Microwave
Page16
256QAM QPSK 16QAM 64QAM 128QAM 256QAM Channel Capability E1 Services Ethernet Services
Page17
Questions
What are the components of OptiX RTN 600? What are the functions of them? What about the connection relation among the
components?
What are the characteristics of OptiX RTN 600 digital microwave equipment?
Page18
Contents
1. Equipment Overview 2. Equipment Structure
Page19
Contents
2. Equipment Structure
2.1 System Diagram and software Structure 2.2 IDU Structure and Boards 2.3 ODU Interfaces and Parameters
Page20
System Diagram
RF signal
ODU Antenna
IDU 610/620
Orderwire data External alarm data Sync./Async. data
IF unit Baseband Baseband SDH/PDH Crosssignal signal service connect interface unit unit Control and overhead bus
Clock unit
Control unit
Fan unit
Power unit
NM data
-48V/-60V DC
Page21
Control unit
Power unit
NM data
-48V/-60V DC or +24V DC
IDU 605
Page22
Software Structure
NM software
SCC
Page23
Contents
2. Equipment Structure
2.1 System Diagram and software Structure 2.2 IDU Structure and Boards 2.3 ODU Interfaces and Parameters 2.4 Hybrid coupler Parameters
Page24
dissipation mode.
IF board
EXT PXC
slot3 slot1
EXT SCC
slot4 slot2
Note: The slot numbering rule is from bottom to up and left to right.
Page25
configuration.
PXC
slot1
SCC
slot2
Page26
IF cable interface
Indicators
Page27
IF cable interface
Indicators
Page28
IF cable interface
GE interface
Indicators
Page29
IF Board -- Types
IF1A/B
IF0A/B
IDU 620
IFX
Providing hybrid
microwave function
(E1+Ethernet)
Page30
EXT PXC
EXT SCC
slot4 slot2
EXT
EXT EXT
SCC
Paired Slots
PXC
IDU 620
Page31
IF Board -- IF Performance
128QAM
27.5 / 28 b
Items
Modulation QPSK 16 QAM 32 QAM 64 QAM 128 QAM 16 QAM 32 QAM 64 QAM Chan. spacing MHz 28 14 14 14 14 28 28 28
Page32
Items
16 E1
10 E1
5 E1
2 E1
Modulation
Channel Spacing (MHz)
QPSK
28(27.5)
QPSK
14(13.75)
QPSK
7
QPSK
3.5
Page33
7 7 7 7
7 7
10 20 25 32
38 44
4 9 12 16
18 21
Page34
14 (13.75)
14 (13.75) 14 (13.75)
32QAM
64QAM 128QAM
51
66 78
24
32 37
14 (13.75)
256QAM
90
43
Page35
28 (27.5)
28 (27.5) 28 (27.5)
64QAM
128QAM 256QAM
133
158 183
64
75 75
Page36
84
168
40
75
56
56 56
32QAM
64QAM 128QAM
208
265 313
75
75 75
56
40
256QAM
64QAM
363
-
75
75
Page37
IFX supports only STM-1 service by 128QAM modulation mode IFX Channel spacing is 27.5 or 28 MHz
Page38
One NE configuration
Waveguide or RF cable
Page39
Page40
5.5 10
Page41
IF Board -- Indicators
Indicator Status On (green) Meaning The board is working normally The board hardware is faulty.
STAT
The board is not working, not created, or has no input power. The service is normal.
The service has a critical or major alarm. The service has a minor or remote alarm.
SRV
On (yellow)
Off
On (green) LINK On (red)
Page42
BER
Off On (yellow)
ACT
Page43
XPIC
(for IFX only)
On
(red)
Off
Page44
Indicator
Page45
indicator
Page46
PH1A/B
16-channel E1 interfaces
PO1A/B
8-channel E1 interfaces
PL3
3-channel E3/DS3 interfaces
75/120 ohm
75/120 ohm
75/120 omh
75 ohm
The interface resistance of PD1/PH1/PO1 boards are set through the jumpers:
If there is a jumper, the resistance is 75 ohm. If there is no jumper, the resistance is 120 ohm.
Front panel
Page47
EXT EXT
EXT SCC
slot8 slot6
slot4 slot2
slot5
slot3
PXC
slot1
IDU 620
Page48
On (green)
STAT On (red) Off On (green) On (red) SRV On (yellow) Off
Page49
Page50
SL4
optical interface
optical interface
S-4.1 interface
L-4.1 interface
L-4.2 interface
SDE
SLE
dual-port STM-1
Single-port STM-1
electrical interface
electrical interface
Page51
155520
L-1.1 G.652 40 1263-1360 5~0 -34 -10 10 L-1.2 G.652 80/100 1480-1580 5~0 -34 -10 10
Multimode fiber
0.5 1260-1360 19~ 14 -23 -14 8.2
Page52
622080
S-4.1
G.652 15
Application code
Optical fiber type Transmission distance (km)
L-4.1
G.652 40
L-4.2
G.652 80
12741356
158 -28 -8 8.2
12801356
32 -28 -8 10
Page53
14801580
32 -28 -8 10
slot3
slot1 IDU 610
EXT SCC
slot4 slot2
slot7
slot5
PXC
Page54
Off
On (red) Off LOS1
SRV
On (red)
Off On (red) Off
LOS2
Page55
and 2 GE services.
RJ45
RJ45 & LC
Page56
EXT
slot3
EXT SCC
slot4 slot2
PXC
slot7
slot5 slot3 slot1
EXT EXT
slot8 slot6
EXT SCC
slot4 slot2
IDU 620
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved. Page57
Multiple encapsulation protocols, 2 VC4 uplink, 4 internal ports, VC12 and VC3 level virtual concatenation, LCAS
Maintenance features
Page58
slot7 slot5
EXT
slot8 slot6
EXT
EXT SCC
slot3
slot1
slot4
slot2
IDU 620
Page59
control
Maintenance features
Page60
PO1
FE
FE
FE GE
PXC
PXC
FE GE
GE
IFH2
ODU
ODU IFH2
GE
Page61
Indicator
Page62
EXT
SCC
slot4
slot2
EXT EXT
EXT SCC
slot8 slot6
slot4 slot2
slot5
slot3
slot1
IDU 620
Page63
PXC -- Indicators
Indicator Status
On (green) STAT On (red) Off On (green) PWR
Meaning
The board is working normally. The board hardware is faulty. The board is not working, or not created, or has no input power. The power is normal.
On (red) Off
SYNC ACT
On (green)
On (red)
On (green)
Off
Flash memory
Indicators
NM interface
NM serial port
NM cascaded interface
Page65
EXT SCC
slot4 slot2
EXT
slot 20 EXT PXC PXC
slot7
slot5 slot3 slot1
IDU 620
EXT EXT
slot8 slot6
EXT SCC
slot4 slot2
Page66
NMS
Connected by Ethernet cable
Page67
Page68
On (green)
STAT On (red) Off On 100 ms and off 100 ms (green) On 300 ms and off 300 ms (green)
PROG
On (green)
On 100 ms and off 100 ms (red)
Page69
On
PROG (red)
During the board power-on/reset, the memory self-test fails or the upper layer software loading fails, or during the board running, the logical file and software are lost. The software is normal.
The system is normal.
Off
On (green)
ALM
On (red)
On (yellow) Off
The system is in maintenance state ( that is, loop-back, laser power-off, and ODU transceiver mute) The system is in working state.
Page70
Indicator
On FAN On Off
Status
Meaning
The fan is working normally. The board is faulty. The board has no input power.
Page71
IDU 605 1A and IDU 605 1B are both 1U height and adopt
IDU 605 1A
IDU 605 1B
Power input
NMS interfaces
Serial interface
ODU interface
Page73
IDU 605 2B
Page74
Orderwir e
Serial interfac e
ODU interface
Page75
Supporting microwave
1+1 configuration.
IDU 605 2F
Page76
ODU interface
Page77
PWR
IDU
Color: red/yellow/green. Show the status of IDU module after system boot up. Red: critical or major alarm generated. Yellow: minor or warning alarm generated. Green: no alarm. Color: red/yellow/green, showing red after power on. Show the status of ODU after system boot up. Red: critical or major alarm generated, or ODU off line. Yellow: minor or warning alarm generated in ODU. Green: no alarm.
ODU
Page78
IDU
ODU1
ODU2
Corresponding to active ODU, the same as IDU 605 1A and IDU 605 1Bs
Color : green, indicator is off after power on. Show the 1+1 backup status after the 1+1 backup group is enabled. On: the standby IF0 is now working. Off: the active IF0 is now working. Color : green, indicator is off after power on. Show the 1+1 backup status after the 1+1 backup group is enabled. On: the active IF0 is now working. Off: the standby IF0 is now working.
ACT1
ACT2
Page79
Boards
PW48B PW24A 48V DC power accessing +24V DC power accessing Slot 1
SCC
EOW
Slot 2
Slot 3
processing
PF1 PH1 5 E1 service accessing and processing 16 E1 service accessing and processing Slot 4
IF0
Page80
EMS4
IFH1
3FE+1GE accessing
Hybrid Microwave and AM supporting
Slot 2
Slot 8IDU605 1F) Slot7/8IDU605 2F)
Page81
Baseband signal
IF signal
RF signal
PF1/ PH1
IF0
ODU
Antenna
Page82
PF1/ PH1
IF0
ODU
Antenna
Page83
PF1/ PH1
IFH1
ODU
Antenna
EMS4
Page84
Clock tracing
Interconnecting with IDU 605, clock free running at primary site and
non-primary site tracing the primary site.
Interconnecting with IDU 620, IDU 605 tracing the clock from IDU 620.
Others
Impedance (75ohm or 120ohm) of E1 signal is set by software. 1+1 backup for the DC power.
Page85
Contents
2. Equipment Structure
2.1 System Diagram and software Structure 2.2 IDU Structure and Boards 2.3 ODU Interfaces and Parameters 2.4 Hybrid coupler Parameters
Page86
ODU -- Interface
Grounding double-screw bolt RSSI test interface IF interface
Antenna port
Page87
Weight
< 5 kg
ODU -- Types
OptiX RTN 600 provides full frequency coverage and multiple ODU, it consists SP,HP and LP series for different conditions.
Description Items SP series Freq. band Service
6/7/8/11/13/15/1 8/23/26/38
HP series
LP series
SDH / PDH
Modulation
Output power
QPSK/16QAN/32QAM/64QAM/128Q
AM/256QAM Standard High
QPSK/16QA
M normal
Page89
Correspondin g ODU
LP/SP LP first.
Remark
IF1A/IF1B IF1A/IF1B
SP SP/HP
LP/SP SP/HP
IDU 620
IF0 IFX/IFH2
Page90
ODU covers from 6G to 38G frequency bands by 3 series, the frequency parameters of LP series is:
Freq.
7GHz
8GHz
11GHz
7.7188.497
10.67511.745
119126151.614208266311.32
490500530
13GHz
15GHz
12.75013.250
14.40015.358
266
315420475490640644728
18GHz
23GHz
17.68519.710
21.20023.618
100810101092.51560
100812001232
Page91
38GHz
37.04440.105
7001260
Page92
7.0937.897
7.7318.497
154160161168196245
119126151.614208266311.32
11GHz
10.67511.745
490500530
266 315420475490640644728 100810101560 100812001232 8001008 812 7001260
13GHz 12.75113.248 15GHz 14.40015.358 18GHz 17.68519.710 23GHz 21.20023.618 26GHz 24.25026.453 32GHz 31.81533.383 38GHz 37.04440.105
Page93
The ODU parameters and types can be get from the ODU label
: Freq. band : ODU type
: Freq. band S-SDH/PDH, P-PDH T/R spacing (MHz) Sub-freq. band P- high site, Nlow site S-Standard power, Hhigh power
: Transmit freq. band (MHz) : T/R spacing (MHz) : Hi-high site, Lo- low site
Page94
Contents
2. Equipment Structure
2.1 System Diagram and software Structure 2.2 IDU Structure and Boards 2.3 ODU Interfaces and Parameters 2.4 Hybrid coupler Parameters
Page95
Antenna port
Page96
Page97
Performance
20
1.2 < 220 mm x 334 mm x 252 mm (waveguide interfaces)
The hybrid coupler parameters and types can be got from label
06-coupling 6d : antenna interface: c-round waveguide, R-rectangular waveguide, F-flange : ODU interface c-round waveguide, R-rectangular waveguide, N: type-N, female
: working freq. range (MHz) : coupling (dB) between the primary branch and the secondary branch.
Page99
Summary
Software Structure: the host and board software are integrated in the SCC and the ODU is a logical board. IDU: includes IDU 610, IDU 620 and IDU 605.
ODU: interface, dimension, weight, power consumption, power indicator, and frequency indicator Hybrid coupler: interface and main indicators
Page100
Summary
Contents Review
Board Functions and Signal Stream in the IDU of OptiX RTN 600
Page101
Thank you
www.huawei.com