You are on page 1of 122

Emergency Lighting Product Catalogue 2012 Edition 2

TEKNOWARE 4

cENTRAl bATTERy uNiTs 8

cENTRAl mONiTORiNg 37

ExiT ANd EmERgENcy lumiNAiREs 42

shOcK pROTEcTiNg cOvERs 118

fREquENTly AsKEd quEsTiONs 119

TERms ANd cONTAcT iNfORmATiON 120

TEKNOWARE OY

TEKNOWARE OY
TEKNOWARE OY is a 100% Finnish company in the international electronics industry. Employing more than 200 people, we engineer and manufacture our products in the city of Lahti, Finland. We have been in the lighting business since 1972. Teknowares 40th anniversary is in May 2012. Our products are used in demanding special lighting applications, such as emergency lighting and interior lighting in public transportation. Exports comprise more than 75% of our sales. Presently, we export our products to over 50 countries and our emergency lighting products can be found around the world, from the concert hall in Reykjavik to the metro in Dubai. Both electronic and mechanical components are engineered and manufactured in our factory in Lahti. Our company has been certified for the ISO 9001 quality assurance system and the ISO 14001 environmental management system.

ldwide re wor a Teknow

Market area

Headquarters and main production Agent/Distributor Sales unit

| There are more than 200 employees at Teknoware. Both electronic and mechanical components are engineered and manufactured in our factory in Lahti, Finland. Also our sales unit is located in Lahti. In addition to partners operating in more than 20 countries around the world, we have sales units in the United Arab Emirates and Spain.

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

EMERGENCY LIGHTING SYSTEMS


In central battery systems the batteries are centrally located, which is a big benefit considering the maintenance work and expenses. In self-contained systems each luminaire has its own back-up power source, usually a battery. As an alternative to the battery, an environmentally friendly and long-life super capacitor is used in the Teknoware ESCAP self-contained luminaires. In our ESCAP emergency lighting luminaires a capacitive storing of electrical energy and the latest LED technology are combined. The life-time of the capacitors is over ten years, which is in balance with the life-time of the long-life high power LEDs. As a result there is a luminaire which is completely maintenance-free during its whole life span. Even after that it is not hazardous waste, but can be recycled as normal electronic waste, unlike the batteries which contain hazardous material and require regular maintenance. As a result of the uniqueness of the solution is the Most Innovative Product award given to Teknoware ESCAP luminaires at the 2008 Shk Valo Tele and AV fair.

products have been certified by SGS Fimko and, therefore, they also carry the FI mark.

LUMINANCE AND CONTRAST REQUIREMENTS FOR EMERGENCY EXIT LUMINAIRES


All emergency exit luminaires sold in Europe must meet the photometric requirements of the European standard EN1838. This standard sets requirements for luminance and contrast. The visibility stated in the standard is the most important feature of an exit luminaire and it cannot be ignored, e.g., for the sake of lower energy consumption or product costs. The only way to make sure that the requirements are met is by measuring with appropriate instruments. Teknoware uses camera-based systems for conducting measurements in its own laboratory and this system fulfils the requirements set

system, reactive power causes additional losses during normal operation and therefore limits the number of luminaires that can be interconnected. Power factor correction is used to limit the wasted reactive power in electronic devices. Power correction is required under European standards. However, it is not mandatory to luminaires with an input power of less than 25 W. Because of this, it is not normally used in low-power luminaires. However, when several low-power luminaires are connected to the same circuit, their overall effect is the same as that of high-power luminaires. For this reason, we have also introduced power factor correction to our low-power emergency luminaires, even when their power is less than 25 W. This benefits the overall energy efficiency of the building and increases flexibility in the design of the emergency lighting system.

PHOTOMETRIC PROPERTIES AND MEASUREMENTS OF EMERGENCY LIGHTING LUMINAIRES


Emergency luminaires are used to illuminate exit routes and open areas at specific light levels. To reach this goal, photometric information on each luminaire type is needed in order to space them correctly. The standards also require that manufacturers of emergency luminaires provide verified photometric data on the luminaires. We supply light level data and spacing tables for all our luminaires. We also offer the necessary Eulumdat files for simulations done with Dialux Software. The data on our luminaires is obtained from real-life measurements and on simulations based on them. Luminous flux (lm) levels are measured in our light laboratory using the Ulbricht sphere.

LED IS GAINING POPULARITY


The luminous intensity and quality of light of LEDs are still developing quickly. Presently, LEDs have reached a level where they are a viable option for various general lighting applications. LEDs have already been used in emergency lighting for years and Teknoware has been one of the forerunners in this field. Fifteen years ago we introduced LEDMAN, our first exit luminaire incorporating green LEDs, and more than 10 years ago we began marketing our first exit luminaires using white LEDs. The development still continues. Today LEDs also play an important role as a light source in emergency luminaires for overall lighting. In comparison to fluorescent tubes, they enable the design of significantly smaller luminaires and also considerably reduce energy consumption. However, the greatest Advantage of LEDs is achieved in their use in continuously operating exit luminaires as LEDs have a lifespan of more than 10 years. In comparison to other light sources, however, new technical challenges face the designers of luminaires using LEDs. Correct thermal engineering is of the utmost importance for long LED lifespan and their photometric characteristics can be utilised only by using correct optics. Teknoware combines extensive experience, as well as the latest engineering tools and instrumentation in its design process.

REMOTE MONITORING SYSTEMS


Teknoware offers a comprehensive range of alternatives for the centralized monitoring of the emergency lighting system. Central monitoring is available for both central battery and self-contained systems. For central battery systems the options are WebACM, WebCM, ACM, BCM, Coba and BACnet, and for self-contained luminaires the wireless Aalto Control system. Further information about the remote monitoring options can be found on pages 37-41 of this catalogue.

PRODUCT COMPLIANCE
Electrical products sold in Europe must always carry the CE mark. This means that low-voltage and EMC (electromagnetic compatibility) directives have been applied to our emergency lighting products. We ensure these requirements are met by engineering and testing our products as per the applicable European standards. We certify this by issuing our products a manufacturers declaration of product compliance, including both the required product documentation and test reports, and accordingly, we attach the CE mark to our products. In addition to the CE mark, our core
Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

THE POWER FACTOR MUST BE CONSIDERED IN DESIGNING LUMINAIRES


The increased use of electronic devices in an electrical grid increases reactive power consumption. Reactive power is generated in alternating current circuits when there is a phase difference between the electrical devices and the power source. Reactive power cannot be utilised, rather, it just produces losses in the supply network With luminaires powered by a central battery

references

Harpa Concert Hall and Conference Centre, Reykjavik, Iceland

Radisson Royal Hotel Dubai, U.A.E.

Helsinki Music Centre, Helsinki, Finland

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRAL BATTERY UNITS

FEATURES OF CENTRAL BATTERY UNIT FAmILIES 8 ADDRESSABLE 230 V CENTRAL BATTERY UNITS | TK23, TKT65, TKT66, TKT67 10 230 V CENTRAL BATTERY UNITS | TK23, TKT65 22 24 V CENTRAL BATTERY UNITS | TKT31, TKT41 26 ACCESSORIES FOR CENTRAL BATTERY UNITS 28 SWITCH CONTROLLER | TS28 32 LOCAL CONTROLLER | TS906, TST68 32 INTELLIGENT CONTROLLER | TST88 35 SWITCHED-mAINTAINED PACKAGE 36 CENTRAL mONITORING OPTIONS 37

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

FEATURES OF CENTRAL BATTERY UNIT FAMILIES

FEATURES OF CENTRAL BATTERY UNIT FAmILIES

Central battery units TKT3122 Basic information Supply voltage Output voltage, mains supply Output voltage, battery supply Battery voltage Max. battery capacity Max. output power, maintained Max. output power, maintained + non-maintained Amount of output circuits Max. output power / Circuit Connection of circuits in parallel Features Self-Testing Addressable testing Circuit Monitoring Interior optional features for Central battery unit Integrated printer LCD Dispaly LON Interface BACnet Interface ACM Interface (RS-485) WebCM Interface (Ethernet) WebACM Interface BCM Interface Switched-Maintained TST1811 XWT3141 TST1811 XWT4141, XWT4142 TST1811 XWT2341, XWT2342 1~ 230 VAC 24 VAC 24 VDC 24 VDC 24 Ah 250 VA 290 W 4 120 VA / W 1~ 230 VAC 24 VAC 24 VDC 24 VDC 100 Ah 1050 VA 1370 W 8-16 120 VA / W 1~ 230 VAC 230 VAC 216 VDC 24 VDC 100 Ah 1-8 x 120 VA 1-8 x120 W 1-8 120 VA / W TKT41xx TK23xx

Extra Charger Module *) Compatibility of external system modules Local Controller Switch Controller Address module Intelligent Controller Intelligent Controller Interface

x x x -

| *) One Extra Charger Module enables to add battery capacity with 180 Ah. | **) TKT66xxCF = three phase input | ***) Circuits can be connected in parallel to increase the output power up to 1400 VA / W
8
Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

TK23xxC

TKT65xxB

TKT65xxC

TKT66xxC

TKT67xxC

TKT68xxC

1~ 230 VAC 230 VAC 216 VDC 24 VDC 100 Ah 1-8 x 120 VA 1-8 x120 W 1-8 120 VA / W -

1~ 230 VAC 230 VAC 216 VDC 216 VDC 65 Ah 1500 VA-2580 VA 2000 W-6000 W 6-24 250 VA / W -

1~ 230 VAC 230 VAC 216 VDC 216 VDC 65 Ah 2000 VA-2580 VA 2000 W-6000 W 8-24 250 VA / W -

1~ 230 VAC **) 230 VAC 216 VDC 216 VDC 65 Ah 2580 VA 2800 W-6000 W 8-24 350 VA / W 1400 VA / W ***) x

3~ 400 VAC 230 VAC 216 VDC 216 VDC 540 Ah 5600 VA-19600 VA 5600 W-19600 W 16-56 350 VA / W 1400 VA / W ***) x

1~ 230 VAC 230 VAC 216 VDC 216 VDC 65 Ah 2580 VA 2800 W-6000 W 8-24 350 VA / W 1400 VA / W ***) x

x x -

x x x

x x x

x x x

x x x

TST2331 XKT2301 TST1811 XWT2341, XWT2342

TST1811 XWT6571, XWT6572, XWT6573

TST6531 TST6532 TST6522 TST6501 TST6521 TST6524 TST6524 TST1811C XWT6571C, XWT6572C, XWT6573C

TST6631 TST6632 TST6622 TST6601 TST6621 TST6624 TST6624 TST1811D XWT6671, XWT6672, XWT6673

TST6731 TST6732 TST6722 TST6701 TST6721 TST6624 TST6624 TST1811E XWT6772, XWT6773, XWT6774, XWT6775, XWT6776, XWT6777 TST6741

TST6831 TST6832 TST6822 TST6823 TST6821 TST6824 TST6824 TST1811F XWT6871, XWT6872, XWT6873

x x x -

x x x -

x x x x TST6551, TST6552, TST6553

x x x x TST6651, TST6652, TST6653

x x x x TST6752, TST6753, TST6754, TST6755, TST6756, TST6757

x x x x TST6851, TST6852, TST6853

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

ADDRESSABLE TAPSA CONTROL SYSTEMS

ADDRESSABLE TAPSA CONTROL SYSTEmS


The addressable testing of the Tapsa Control central battery unit, together with a wide selection of central monitoring options, offers considerable savings in system maintenance and service. The addressable central battery units offer effective solutions for supplying a large quantity of luminaires. They are suited for small and large premises depending on the type of the central battery unit. A maximum of 12-32 addressable luminaires can be connected to one circuit depending on the type of the central battery unit. In addition to the normal emergency lighting functions, central battery units in the Tapsa Control series make it possible to test automatically the condition of the central unit itself and the luminaires connected to it. The testing of luminaires is based on individual addresses and the communication is by means of the power supply cables. Thus there is no need for any separate data cabling between the luminaires. The luminaires must be of the Teknoware model number ending in the letter K or they must have a separate address module. Utilisation of these luminaires also enables the connection of maintained and non-maintained luminaires to the same circuit and allows local supply monitoring using Teknoware Local Controller. Tapsa Control series include all the basic functions required by the EN50171 standard. Moreover, the following additional features, among others, are available: - The system is self-learning, which enables automatic configuration during the commissioning. - The system performs an automatic luminaire test once every day and a battery test once every six months. - In addition to the scheduled tests, the condition of the batteries is monitored continuously. - They are fully compatible with Teknoware Local Contoller and Switch Controller as well as Intelligent Controller. - Customers can program battery operation to continue from 1 to 15 minutes after electric power has been restored (not available in TK23xxC series).

emergency and exit luminaires in the same circuit

mains supply

Tapsa Control CBU

1 2 3

32

up to 32 luminaires in the same circuit free circuit arrangement

Battery Cabinet

= non-maintained luminaire = maintained exit luminaire

10

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

references

Radnti Community Centre, Budapest, Hungary

Main Skating Rink, Budapest, Hungary

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

11

CENTRAL BATTERY UNITS / 230 V ADDRESSABLE

TAPSA CONTROL TKT67xxC

EN50171

IP 21

A MAXIMUM OF 32 ADDRESSABLE LUMINAIRES / ONE CIRCUIT

ALWAYS NEEDS 18 BATTERIES, A BATTERY CABINET + BATTERY CABLES

Central battery units in the TK67 series offer effective solutions for supplying a large quantity of luminaires. They are especially suited for large premises. The central unit input voltage is 230 VAC. The output voltage is 230 VAC in normal mode and 216 VDC in battery mode. The battery voltage is 216 V, which is achieved by connecting eighteen 12 volt batteries in series. In addition to the normal emergency lighting functions, central battery units in the Tapsa Control TKT67xxC series make it possible to test automatically

the condition of the central unit itself and the luminaires connected to it. The testing of luminaires is based on individual addresses and the communication is by means of the power supply cables. Thus there is no need for any separate data cabling between the luminaires. The luminaires must be of the Teknoware model number ending in the letter K or they must have a separate address module. Utilisation of these luminaires also enables the connection of maintained and non-maintained luminaires to the same circuit and allows local supply monitoring using Teknoware Local Controller, or Intelligent Controller,

which can also be used to control the non-maintained emergency luminaires. These central battery units have, depending on the model, either 16, 24, 32, 40, 48 or 56 output circuits, which can be set to function as maintained or non-maintained. A maximum of 32 addressable luminaires can be connected to one circuit. Circuits can also be connected in parallel to increase the output power with the following changeover module outputs possible: 8 x 350 VA, 4 x 700 VA or 2 x 1400 VA.

DIMENSIONS
602 505 602

505 1950 1950

R597

12

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

TYPE OF THE PANEL


Product code TKT6716C TKT6724C TKT6732C TKT6740C TKT6748C TKT6756C GTIN code 6438045009551 6438045009568 6438045009575 6438045009582 6438045009599 6438045009605 Max input power (mains) 8600 VA 11400 VA 14200 VA 17200 VA 20000 VA 22800 VA Number of circuits / Outputs 16 circuits each 350 W 2 x (8x350 W / 4x700 W / 2x1400 W) 24 circuits each 350 W 3 x (8x350 W / 4x700 W / 2x1400 W) 32 circuits each 350 W 4 x (8x350 W / 4x700 W / 2x1400 W) 40 circuits each 350 W 5 x (8x350 W / 4x700 W / 2x1400 W) 48 circuits each 350 W 6 x (8x350 W / 4x700 W / 2x1400 W) 56 circuits each 350 W 7 x (8x350 W / 4x700 W / 2x1400 W) Max load, maintained luminaires 5600 VA 8400 VA 11200 VA 14000 VA 16800 VA 19600 VA Max total load 1-3 h durations 5600 W 8400 W 11200 W 14000 W 16800 W 19600 W Weight (kg) 120,0 121,0 122,0 123,0 124,0 125,0

| Output voltage: 230 V | Batteries : 18 x 12 V (216 V) | Charger: 1 pc as a standard for Max 180 Ah batteries | Supply voltage: 3 ~ 400 V AC 50-60 Hz | Max battery capacity: 400 Ah

BATTERIES (18 x TEAxx / xxAh)


Product code GTIN code Battery capacity Max load, 1 h operation time 7500 W 11780 W 17670 W 19600 W Max load , 3 h operation time 3340 W 5050 W 7580 W 10010 W 15160 W 19600 W Battery cabinet TKT6500 x 3 TKT6500 x 3 TKT6500 x 3 TKT6500 x 3 TKT6500 x 3 TKT6500 x 3 Battery cable XJ997E XJ997E XJ997E XJ997E XJ997E XJ997E Dimensions of the battery 350 x 166 x 174 327 x 168 x 210 485 x 172 x 240 Weight of the battery (kg) 22,8 33,5 47,0

TEA024 TEA024B TEA024D TEA024C

6438045000862 6438045004396 6438045005867 6438045010472

65 Ah 100 Ah 150 Ah 200 Ah 300 Ah ( 2 x 150 Ah) 400 Ah ( 2 x 200 Ah)

| A 10 % reserve is recommended for the loads (W) mentioned in the table.

BATTERY CABINETS
Product code TKT6500 GTIN code 6438045006819 Battery capacity 6 x 12 V / 100 Ah Weight (kg) 28,0

BATTERY CABLES
Product code XJ997E GTIN code 6438045006291 Length of the battery cable (m) 3,5 For For three TKT6500 battery cabinets

OPTIONAL FEATURES
Product code TST6731 TST6732 TST6741 XWT6771 XWT6772 XWT6773 XWT6774 XWT6775 XWT6776 XWT6777 TST6751 TST6752 TST6753 TST6754 TST6755 TST6756 TST6757 GTIN code 6438045008509 6438045008547 6438045008585 6438045009902 6438045009919 6438045009926 6438045009933 6438045009940 6438045009957 6438045009964 6438045009971 6438045009988 6438045009995 6438045010007 6438045010014 6438045010021 6438045010038 Product description Integrated Printer LCD Display Module

| Please note a peeling reserve in the length of the battery cable For TKT67xxC TKT67xxC TKT67xxC TKT6708C TKT6716C TKT6724C TKT6732C TKT6740C TKT6748C TKT6756C TKT6708C TKT6716C TKT6724C TKT6732C TKT6740C TKT6748C TKT6756C

Extra Charger Module (1-2 pcs each 3000 VA, Max each 180 Ah) Switched-Maintained Package for 8 circuits each 350 W Switched-Maintained Package for 16 circuits each 350 W Switched-Maintained Package for 24 circuits each 350 W Switched-Maintained Package for 32 circuits each 350 W Switched-Maintained Package for 40 circuits each 350 W Switched-Maintained Package for 48 circuits each 350 W Switched-Maintained Package for 56 circuits each 350 W IC Interface for 8 circuits each 350 W IC Interface for 16 circuits each 350 W IC Interface for 24 circuits each 350 W IC Interface for 32 circuits each 350 W IC Interface for 40 circuits each 350 W IC Interface for 48 circuits each 350 W IC Interface for 56 circuits each 350 W

Central monitoring options: TST6722 TST6701 TST6721 TST6724 TST1811E 6438045008592 6438045008639 6438045008677 6438045008714 6438045008752 LON Interface BACnet Interface ACM Interface WebCM/ WebACM Interface BCM Interface TKT67xxC TKT67xxC TKT67xxC TKT67xxC TKT67xxC
13

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRAL BATTERY UNITS / 230 V ADDRESSABLE

TAPSA CONTROL TKT68xxCx

EN50171

IP 20

A MAXIMUM OF 32 ADDRESSABLE LUMINAIRES / ONE CIRCUIT

NO SEPARATE BATTERY CABINET NEEDED

Central battery units in the TK68 series offer effective and space-saving solutions for supplying a moderate quantity of luminaires. They are especially suited for mid-sized and large premises where it is desirable to divide the central battery system into multiple independent regions. The central unit input voltage is 230 VAC, except for three phase input models (that end with letter F) the input voltage is 400 VAC. The output voltage is 230 VAC in normal mode and 216 VDC in battery mode. The battery voltage is 216 V, which is achieved by connecting eighteen 12 volt batteries in series. TKT68xxC central battery unit can accommodate batteries up to 18 x 65 Ah into its casing; therefore, it is well suited

for locations where only a limited amount of space is available. In addition to the normal emergency lighting functions, central battery units in the Tapsa Control TKT68xxC series make it possible to test automatically the condition of the central unit itself and the luminaires connected to it. The testing of luminaires is based on individual addresses and the communication is by means of the power supply cables. Thus there is no need for any separate data cabling between the luminaires. The luminaires must be of the Teknoware model number ending in the letter K or they must have a separate address module. Utilisation of these luminaires also enables the connection of maintained and non-maintained

luminaires to the same circuit and allows local supply monitoring using Teknoware Local Controller, or Intelligent Controller, which can also be used to control the non-maintained emergency luminaires. These central batteryunits have, depending on the model, either 8, 16 or 24 output circuits, which can be set to function as maintained of non-maintained. A maximum of 32 addressable luminaires can be connected to one circuit. Circuits can also be connected in parallel to increase the output power with the following changeover module outputs possible: 8 x 350 VA, 4 x 700 VA or 2 x 1400 VA.

DIMENSIONS
800 512 800

512

1930

1930 R590 R188 R796

14

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

TYPE OF THE PANEL


Product code GTIN code Max input power (mains) 3680 VA 3900 VA 3680 VA 6700 VA 3680 VA 9500 VA Number of circuits/ Outputs 8 circuits each 350 W 1 x (8x350 W / 4x700 W / 2x1400 W) 8 circuits each 350 W 1 x (8x350 W / 4x700 W / 2x1400 W) 16 circuits each 350 W 2 x (8x350 W / 4x700 W / 2x1400 W) 16 circuits each 350 W 2 x (8x350 W / 4x700 W / 2x1400 W) 24 circuits each 350 W 3 x (8x350 W / 4x700 W / 2x1400 W) 24 circuits each 350 W 3 x (8x350 W / 4x700 W / 2x1400 W) Max load, maintained luminaires 2000 VA 2800 VA 2580 VA 5600 VA 2580 VA 8400 VA Max total load, 1 h duration 2800 W 2800 W 5600 W 5600 W 6000 W 6000 W Max total load, 3 h duration 2800 W 2800 W 3340 W 3340 W 3340 W 3340 W Weight (kg) 145,0 145,0 147,0 147,0 150,0 150,0

TKT6808C TKT6808CF TKT6816C TKT6816CF TKT6824C TKT6824CF

6438045009612 6438045010045 6438045009629 6438045010052 6438045009636 6438045010069

| Output voltage: 230 V | Batteries : 18 x 12 V (216 V) | Supply voltage: 1 ~ 230 V AC 50-60 Hz | Max battery capacity: 65 Ah | F-letter at the end of the product code: three phase input

BATTERIES (18 x TEAxx / xxAh)


Product code GTIN code Size of the battery (Ah) 6,5 Ah Max load, 1 h operation time 870 W Max load, 3 h operation time 350 W Battery cabinet Battery cable XJ997G Dimensions of the battery (mm) 151 x 65 x 98 Weight of the battery (kg) 2,4

TEA020

6438045000824

No separate battery cabinet needed No separate battery cabinet needed No separate battery cabinet needed No separate battery cabinet needed No separate battery cabinet needed

TEA021

6438045000831

15 Ah

1700 W

770 W

XJ997F

181 x 76 x 167

5,9

TEA022

6438045000848

24 Ah

2720 W

1250 W

XJ997F

166 x 175 x 125

8,7

TEA023

6438045000855

38 Ah

4550 W

2050 W

XJ997F

197 x 165 x 173

13,8

TEA024

6438045000862

65 Ah

6000 W

3340 W

XJ997F

350 x 166 x 174

22,8

| A 10 % reserve is recommended for the loads (W) mentioned in the table.

BATTERY CABLES
Product code XJ997F XJ997G GTIN code 6438045008806 6438045008813 For 15 Ah batteries 6,5 Ah batteries

OPTIONAL FEATURES
Product code TST6831 TST6832 XWT6871 XWT6872 XWT6873 TST6851 TST6852 TST6853 GTIN code 6438045008516 6438045008554 6438045010076 6438045010083 6438045010090 6438045010106 6438045010113 6438045010120 Product description Integrated Printer LCD Display Module Switched-Maintained Package for 8 circuits each 350 W Switched-Maintained Package for 16 circuits each 350 W Switched-Maintained Package for 24 circuits each 350 W IC Interface for 8 circuits each 350 W IC Interface for 16 circuits each 350 W IC Interface for 24 circuits each 350 W For TKT68xxC TKT68xxC TKT6808C TKT6816C TKT6824C TKT6808C TKT6816C TKT6824C

Central monitoring options: TST6822 TST6823 TST6821 TST6824 TST1811F 6438045008608 6438045008646 6438045008684 6438045008721 6438045008769 LON Interface BACnet Interface ACM Interface WebCM/ WebACM Interface BCM Interface TKT68xxC TKT68xxC TKT68xxC TKT68xxC TKT68xxC
15

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRAL BATTERY UNITS / 230 V ADDRESSABLE

TAPSA CONTROL TKT66xxCx

EN50171

IP 20

A MAXIMUM OF 32 ADDRESSABLE LUMINAIRES / ONE CIRCUIT

ALWAYS NEEDS 18 BATTERIES, A BATTERY CABINET + BATTERY CABLES

Central battery units in the TK66 series offer effective and space-saving solutions for supplying a moderate quantity of luminaires. They are especially suited for mid-sized and large premises where it is desirable to divide the central battery system into multiple independent regions. The central unit input voltage is 230 VAC, except for three phase input models (that end with letter F) the input voltage is 400 VAC. The output voltage is 230 VAC in normal mode and 216 VDC in battery mode. The battery voltage is 216 V, which is achieved by connecting eighteen 12 volt batteries in series. In addition to the normal emergency

lighting functions, central battery units in the Tapsa Control TKT66 series make it possible to test automatically the condition of the central unit itself and the luminaires connected to it. The testing of luminaires is based on individual addresses and the communication is by means of the power supply cables. Thus there is no need for any separate data cabling between the luminaires. The luminaires must be of the Teknoware model number ending in the letter K or they must have a separate address module. Utilisation of these luminaires also enables the connection of maintained and non-maintained luminaires to the same circuit and allows

local supply monitoring using Teknoware Local Controller, or Intelligent Controller, which can also be used to control the non-maintained emergency luminaires. These central units have, depending on the model, either 8, 16 or 24 output circuits, which can be set to function as maintained of non-maintained. A maximum of 32 addressable luminaires can be connected to one circuit. Circuits can also be connected in parallel to increase the output power with the following changeover module outputs possible: 8 x 350 VA, 4 x 700 VA or 2 x 1400 VA.

DIMENSIONS

600

240

215

240

780

780

600

16

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

TYPE OF THE PANEL


Product code GTIN code Max input power (mains) 3680 VA 3900 VA 3680 VA 6700 VA 3680 VA 9500 VA Number of circuits / Outputs 8 circuits each 350 W 1 x (8x350 W / 4x700 W / 2 x1400 W) 8 circuits each 350 W 1 x (8x350 W / 4x700 W / 2 x1400 W) 16 circuits each 350 W 2 x (8x350 W / 4x700 W / 2 x1400 W) 16 circuits each 350 W 2 x (8x350 W / 4x700 W / 2 x1400 W) 24 circuits each 350 W 3 x (8x350 W / 4x700 W / 2 x1400 W) 24 circuits each 350 W 3 x (8x350 W / 4x700 W / 2 x1400 W) Max load, maintained luminaires 2580 VA 2800 VA 2580 VA 5600 VA 2580 VA 8400 VA Max total load, 1 h duration 2800 W 2800 W 5600 W 5600 W 6000 W 6000 W Max total load, 3 h duration 2800 W 2800 W 3340 W 3340 W 3340 W 3340 W Weight (kg) 32,8 32,8 33,8 33,8 34,8 34,8

TKT6608C TKT6608CF TKT6616C TKT6616CF TKT6624C TKT6624CF

6438045007748 6438045010137 6438045007755 6438045010144 6438045007762 6438045010151

| Output voltage: 230 V | Batteries : 18 x 12 V (216V) | Supply voltage: 1 ~ 230 V AC 50-60 Hz | Max battery capacity: 65 Ah | F-letter at the end of the product code: three phase input

BATTERIES (18 x TEAxx / xxAh)


Product code GTIN code Size of the battery (Ah) 6,5 Ah 15 Ah 24 Ah 38 Ah 65 Ah Max load, 1 h operation time 870 W 1700 W 2720 W 4550 W 6000 W Max load, 3 h operation time 350 W 770 W 1250 W 2050 W 3340 W Battery cabinet TK6500B TK6500B TK6500B x 2 TK6500B x 3 TKT6500 x 3 Battery cable XJ997B XJ997 XJ997C XJ997C XJ997E Dimensions of the battery (mm) 151 x 65 x 98 181 x 76 x 167 166 x 175 x 125 197 x 165 x 173 350 x 166 x 174 Weight of the battery (kg) 2,4 5,9 8,7 13,8 22,8

TEA020 TEA021 TEA022 TEA023 TEA024

6438045000824 6438045000831 6438045000848 6438045000855 6438045000862

| A 10 % reserve is recommended for the loads (W) mentioned in the table.

BATTERY CABINETS
Product code TK6500B TKT6500 GTIN code 6438045006284 6438045006819 Battery capacity 18 x 12 V / 15 Ah 6 x 12 V / 100 Ah Weight (kg) 14,0 28,0

BATTERY CABLES
Product code XJ997B XJ997 XJ997C XJ997E GTIN code 6438045003627 6438045003634 6438045005140 6438045006291 Length of the battery cable (m) 1,5 1,5 2,5 3,5 For 6,5 Ah batteries 15 Ah batteries For two battery cabinets For three TKT6500 battery cabinets

OPTIONAL FEATURES
Product code TST6631 TST6632 XWT6691 XWT6671 XWT6672 XWT6673 TST6651 TST6652 TST6653 GTIN code 6438045008523 6438045008561 6438045010199 6438045010168 6438045010175 6438045010182 6438045010205 6438045010212 6438045010229 Product description Integrated Printer LCD Display Module Charger Module

| Please note a peeling reserve in the length of the battery cable For TKT66xxC TKT66xxC TKT66xxC TKT6608C TKT6616C TKT6624C TKT6608C TKT6616C TKT6624C

Switched-Maintained Package for 8 circuits each 350 W Switched-Maintained Package for 16 circuits each 350 W Switched-Maintained Package for 24 circuits each 350 W IC Interface for 8 circuits each 350 W IC Interface for 16 circuits each 350 W IC Interface for 24 circuits each 350 W

Central monitoring options: TST6622 TST6601 TST6621 TST6624 TST1811D 6438045008615 6438045008653 6438045008691 6438045008738 6438045008776 LON Interface BACnet Interface ACM Interface WebCM/ WebACM Interface BCM Interface TKT66xxC TKT66xxC TKT66xxC TKT66xxC TKT66xxC

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

17

CENTRAL BATTERY UNITS / 230 V ADDRESSABLE

TAPSA CONTROL TKT65xxC

EN50171

IP 20

A MAXIMUM OF 16 ADDRESSABLE LUMINAIRES / ONE CIRCUIT

ALWAYS NEEDS 18 BATTERIES, A BATTERY CABINET + BATTERY CABLES

Central battery units in the TK65 series offer effective solutions for supplying a moderate number of luminaires. They are especially suited for mid-sized and large premises where it is desirable to divide the central system into multiple independent regions. The central unit input voltage is 230 VAC, except for three phase input models (that end with letter F) the input voltage is 400 VAC. The output voltage is 230 VAC in normal mode and 216 VDC in battery mode. The battery voltage is 216 V, which is achieved by connecting eighteen 12 volt batteries in series.

In addition to the normal emergency lighting functions, central battery units in the Tapsa Control TKT65xxC series make it possible to test automatically the condition of the central unit itself and the luminaires connected to it. The testing of luminaires is based on individual addresses and the communication is by means of the power supply cables. Thus there is no need for any separate data cabling between the luminaires. The luminaires must be of the Teknoware model number ending in the letter K or they must have a separate address module. Utilisation of these luminaires also enables the connection

of maintained and non-maintained luminaires to the same circuit and allows local supply monitoring using Teknoware Local Controller, or Intelligent Controller, which can also be used to control the non-maintained emergency luminaires. These central units have, depending on the model, either 8, 16 or 24 output circuits, which can be set to function as maintained or non-maintained. A maximum of 16 addressable luminaires can be connected to one circuit.

DIMENSIONS
239

518

518

765

765

239

211

211

18

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

TYPE OF THE PANEL


Product code TKT6508C TKT6516C TKT6524C GTIN code 6438045006222 6438045006239 6438045006246 Max input power (mains) 3100 VA 3680 VA 3680 VA Number of circuits/ Outputs 8 circuits each 250 W 16 circuits each 250 W 24 circuits each 250 W Max load, maintained luminaires 2000 VA 2580 VA 2580 VA Max total load, 1 h duration 2000 W 4000 W 6000 W Weight (kg) 29,5 30,0 30,5

| Output voltage: 230 V | Batteries: 18 x 12 V (216 V) | Supply voltage: 1 ~ 230 V AC 50 Hz

| Max battery capacity: 65 Ah

BATTERIES (18 x TEAxx / xxAh)


Product code GTIN code Size of the battery (Ah) 6,5 Ah 15 Ah 24 Ah 38 Ah 65 Ah Max load, 1 h operation time 870 W 1700 W 2720 W 4550 W 6000 W Max load, 3 h operation time 350 W 770 W 1250 W 2050 W 3340 W Battery cabinet TK6500B TK6500B TK6500B x 2 TK6500B x 3 TKT6500 x 3 Battery cable XJ997B XJ997 XJ997C XJ997C XJ997E Dimensions of the battery (mm) 151 x 65 x 98 181 x 76 x 167 166 x 175 x 125 197 x 165 x 173 350 x 166 x 174 Weight of the battery (kg) 2,4 5,9 8,7 13,8 22,8

TEA020 TEA021 TEA022 TEA023 TEA024

6438045000824 6438045000831 6438045000848 6438045000855 6438045000862

| A 10 % reserve is recommended for the loads (W) mentioned in the table.

BATTERY CABINETS
Product code TK6500B TKT6500 GTIN code 6438045006284 6438045006819 Battery capacity 18 x 12V / 15 Ah 6 x 12 V / 100 Ah Weight (kg) 14,0 28,0

BATTERY CABLES
Product code XJ997B XJ997 XJ997C XJ997E GTIN code 6438045003627 6438045003634 6438045005140 6438045006291 Length of the battery cable (m) 1,5 1,5 2,5 3,5 For For 6,5 Ah batteries For 15 Ah batteries For two battery cabinets For three TKT6500 battery cabinets

| Please note a peeling reserve in the length of the battery cable

OPTIONAL FEATURES
Product code TST6531 TST6532 XWT6571C XWT6572C XWT6573C TST6551 TST6552 TST6553 GTIN code 6438045008530 6438045008578 6438045010236 6438045010243 6438045010250 6438045010267 6438045010274 6438045010281 Product description Integrated Printer LCD Display Module Switched-Maintained Package for 8 circuits each 250 W Switched-Maintained Package for 16 circuits each 250 W Switched-Maintained Package for 24 circuits each 250 W IC Interface for 8 circuits each 250 W IC Interface for 16 circuits each 250 W IC Interface for 24 circuits each 250 W For TKT65xxC TKT65xxC TKT6508C TKT6516C TKT6524C TKT6508C TKT6516C TKT6524C

Central monitoring options: TST6522 TST6501 TST6521 TST6524 TST1811C 6438045008622 6438045008660 6438045008707 6438045008745 6438045008783 LON Interface BACnet Interface ACM Interface WebCM/ WebACM-Interface BCM Interface TKT65xxC TKT65xxC TKT65xxC TKT65xxC TKT65xxC

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

19

CENTRAL BATTERY UNITS / 230 V ADDRESSABLE

TAPSA CONTROL TK23xxC

EN50171

IP 20

A MAXIMUM OF 12 ADDRESSABLE LUMINAIRES / ONE CIRCUIT

ALWAYS NEEDS 2 BATTERIES, A BATTERY CABINET + BATTERY CABLES

Central battery units in the TK23 series offer simple solutions for supplying a relatively small number of luminaires. They are especially suited for small and midsized premises and applications where it is desirable to divide the central battery system into multiple independent regions. The central unit input voltage is 230 VAC. The output voltage is 230 VAC in normal mode and 230 VDC in battery mode. The battery voltage is 24 V, which is achieved by connecting two 12 volt batteries in series. The central battery unit has switch mode converters to raise the 24 VDC battery voltage to a 230 VDC output voltage when operating in battery mode.

This technology makes it possible to have an economical and compact battery pack and yet have all the benefits of a 230 VDC output voltage, such as low voltage losses in output cables. In addition to the normal emergency lighting functions, central battery units in the Tapsa Control TK23 series make it possible to test automatically the condition of the central unit itself and the luminaires connected to it. The testing of luminaires is based on individual addresses and the communication is by means of the power supply cables. Thus there is no need for any separate data cabling between the

luminaires. The luminaires must be of the Teknoware model number ending in the letter K or they must have a separate address module. Utilisation of these luminaires also enables the connection of maintained and non-maintained luminaires to the same circuit and allows local supply monitoring using Teknoware Local Controller. These central units have, depending on the model, from 1 to 8 output circuits, each of which can be set to function as maintained or non-maintained. A maximum of 12 addressable luminaires can be connected to one circuit.

DIMENSIONS
518 239

518

239 764 764

20

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

TYPE OF THE PANEL


Product code TK2301C TK2302C TK2303C TK2304C TK2305C TK2306C TK2307C TK2308C GTIN code 6438045004037 6438045004044 6438045004051 6438045004068 6438045004075 6438045004082 6438045004099 6438045004105 Max input power (mains) 370 VA 490 VA 610 VA 730 VA 850 VA 970VA 1090 VA 1210 VA Number of circuits/ Outputs 1 circuit each 120 W 2 circuits each 120 W 3 circuits each 120 W 4 circuits each 120 W 5 circuits each 120 W 6 circuits each 120 W 7 circuits each 120 W 8 circuits each 120 W Weight (kg) 18,0 18,5 19,0 20,0 20,5 21,5 22,0 23,0

| Output voltage: 230 V | Batteries: 2 x 12 V (24 V) | Max total load of the Central battery Unit =amount of circuits x 120 W | Supply voltage: 1 ~ 230 V AC 50 Hz | Max battery capacity: 100 Ah

BATTERIES (2 x TEAxx / xxAh)


Product code GTIN code Size of the battery (Ah) 6,5 Ah 15 Ah 24 Ah 38 Ah 65 Ah 100 Ah 150 Ah Max load, 1 h operation time 80 W 150 W 245 W 415 W 680 W 960 W Max load, 3 h operation time 34 W 70 W 115 W 185 W 305 W 480 W 730 W Battery cabinet TK2300 TK2300 TK2300 TK2300 TK4100 TK2310 TK2310 Battery cable XJ995 XJ996 XJ996 XJ996 XJ996 XJ996 XJ996 Dimensions of the battery (mm) 151 x 65 x 98 181 x 76 x 167 166 x 175 x 125 197 x 165 x 173 350 x 166 x 174 327 x 168 x 210 485 x 172 x 240 Weight of the battery (kg) 2,4 5,9 8,7 13,8 22,8 33,5 47,0

TEA020 TEA021 TEA022 TEA023 TEA024 TEA024B TEA024D

6438045000824 6438045000831 6438045000848 6438045000855 6438045000862 6438045004396 6438045005867

| A 10 % reserve is recommended for the loads (W) mentioned in the table.

BATTERY CABINETS
Product code TK2300 TK2310 TK4100 GTIN code 6438045004112 6438045004129 6438045003443 Battery capacity 2 x 12 V / 38 Ah 2 x 12 V / 150 Ah 2 x 12V / 65 Ah Weight (kg) 6,3 kg 15,5 kg 10,0 kg

BATTERY CABLES
Product code XJ995 XJ996 GTIN code 6438045003603 6438045003610 Length of the battery cable (m) 1,5 1,5 For 6,5 Ah batteries 15 Ah batteries

| Please note a peeling reserve in the length of the battery cable

OPTIONAL FEATURES
Product code TST2331 XWT2341 XWT2342 GTIN code 6438045010298 6438045010304 6438045010311 Product description Integrated Printer Switched-Maintained Package for 4 circuits each 120 W Switched-Maintained Package for 8 circuits each 120 W For TK23xxC TK2301C-04C TK2305C-08C

Central monitoring options: TST1811 XKT2301 6438045008790 6438045006833 BCM Interface LON Interface TK23xxC TK23xxC

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

21

CENTRAL BATTERY UNITS / 230 V

TKT65xxB

EN50171

IP 20

ALWAYS NEEDS 18 BATTERIES, A BATTERY CABINET + BATTERY CABLES

Central battery units in the TK65 series offer simple solutions for supplying a moderate number of luminaires. They are especially suited for mid-sized and large premises where it is desirable to divide the central battery system into multiple independent regions.

The central battery unit input voltage is 230 VAC. The output voltage is 230 VAC in normal mode and 216 VDC in battery mode. The battery voltage is 216 V, which is achieved by connecting eighteen 12 volt batteries in series.

These central battery units have, depending on the model, either 6, 12, 18 or 24 output circuits, which can be set to function as maintained or non-maintained in groups of two.

DIMENSIONS
239

518

518

765

765

239

211

211

22

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

TYPE OF THE PANEL


Product code TKT6506B TKT6506BF TKT6512B TKT6512BF TKT6518B TKT6518BF TKT6524B TKT6524BF GTIN code 6438045004341 6438045010328 6438045004358 6438045010335 6438045004365 6438045010342 6438045004372 6438045010359 Max input power (mains) 2600 VA 2600 VA 3680 VA 4100 VA 3680 VA 5600 VA 3680 VA 7100 VA Number of circuits/ Outputs 6 circuits each 250 W 6 circuits each 250 W 12 circuits each 250 W 12 circuits each 250 W 18 circuits each 250 W 18 circuits each 250 W 24 circuits each 250 W 24 circuits each 250 W Max load, maintained luminaires 1500 VA 1500 VA 2580 VA 2580 VA 2580 VA 2580 VA 2580 VA 2580 VA Max total load, 1 h duration 2000 W 2000 W 3000 W 3000 W 4500 W 4500 W 6000 W 6000 W Weight (kg) 27,8 27,8 30,0 30,0 31,0 31,0 31,6 31,6

| Output voltage: 230 V | Batteries : 18 x 12 V (216 V) | Max total load of the Central battery Unit =amount of circuits x 120 W | F-letter at the end of the product code: three phase input | Supply voltage: 230 V 1 ~ 50-60 Hz | Max battery capacity: 65 Ah

BATTERIES (18 x TEAxx / xxAh)


Product code GTIN code Size of the battery (Ah) 6,5 Ah 15 Ah 24 Ah 38 Ah 65 Ah Max load, 1 h operation time 870 W 1700 W 2720 W 4550 W 6000 W Max load, 3 h operation time 350 W 770 W 1250 W 2050 W 3340 W Battery cabinet TK6500B TK6500B TK6500B x 2 TK6500B x 3 TKT6500 x 3 Battery cable XJ997B XJ997 XJ997C XJ997C XJ997E Dimensions of the battery (mm) 151 x 65 x 98 181 x 76 x 167 166 x 175 x 125 197 x 165 x 173 350 x 166 x 174 Weight of the battery (kg) 2,4 5,9 8,7 13,8 22,8

TEA020 TEA021 TEA022 TEA023 TEA024

6438045000824 6438045000831 6438045000848 6438045000855 6438045000862

| A 10 % reserve is recommended for the loads (W) mentioned in the table.

BATTERY CABINETS
Product code TK6500B TKT6500 GTIN code 6438045006284 6438045006819 Battery capacity 18 x 12 V / 15 Ah 6 x 12 V / 65 Ah Weight (kg) 14,0 28,0

BATTERY CABLES
Product code XJ997B XJ997 XJ997C XJ997E GTIN code 6438045003627 6438045003634 6438045005140 6438045006291 Length of the battery cable (m) 1,5 1,5 2,5 3,5 For 6,5 Ah batteries 15 Ah batteries For two battery cabinets For three TKT6500 battery cabinets

OPTIONAL FEATURES
Product code XWT6571 XWT6572 XWT6573 GTIN code 6438045010366 6438045010373 6438045010380 Product description Switched-Maintained Package for 6 circuits each 250 W Switched-Maintained Package for 12 circuits each 250 W Switched-Maintained Package for 18-24 circuits each 250 W For TKT6506B TKT6512B TKT6518B-TKT6524B

Central monitoring options: TST1811 6438045008790 BCM Interface TKT65xxB

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

23

CENTRAL BATTERY UNITS / 230 V

TK23xx

EN50171

IP 20

TK2301-TK2304 HAvE SPACE FOR 2 X 12 v / 38 AH BATTERIES

TK2305-TK2308 NEED 2 BATTERIES, BATTERY CABLES AND A BATTERY CABINET

Central battery units in the TK23 series offer simple solutions for supplying a relatively small number of luminaires. They are especially suited for small and midsized premises and applications where it is desirable to divide the central battery system into multiple independent regions. The central unit input voltage is 230 VAC. The output voltage is 230 VAC in normal

mode and 230 VDC in battery mode. The battery voltage is 24 V, which is achieved by connecting two 12 volt batteries in series. The central battery unit has switch mode converters to raise the 24 VDC battery voltage to a 230 VDC output voltage when operating in battery mode. This technology makes it possible to have an economical and compact battery pack and yet have all the benefits of a 230

VDC output voltage, such as low voltage losses in output cables. These central units have, depending on the model, from 1 to 8 output circuits, each of which can be set to function as maintained or non-maintained or periodically.

DIMENSIONS

419

244

419

601

601

244

24

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

TYPE OF THE PANEL


Product code TK2301 TK2302 TK2303 TK2304 TK2305 TK2306 TK2307 TK2308 GTIN code 6438045003368 6438045003375 6438045003382 6438045003399 6438045003405 6438045003412 6438045003429 6438045003436 Max input power (mains) 370 VA 490 VA 610 VA 730 VA 850 VA 970VA 1090 VA 1210 VA Number of circuits/ Outputs 1 circuit each 120 W 2 circuits each 120 W 3 circuits each 120 W 4 circuits each 120 W 5 circuits each 120 W 6 circuits each 120 W 7 circuits each 120 W 8 circuits each 120 W Space for the batteries inside the panel 2 x 12 V (38 Ah) 2 x 12 V (38 Ah) 2 x 12 V (38 Ah) 2 x 12 V (38 Ah) Weight (kg) 15,0 15,5 16,0 16,5 17,0 17,5 18,0 18,5

| Output voltage: 230 V | Batteries : 2 x 12 V (24 V) | Max total load of the Central battery Unit =amount of circuits x 120 W | Supply voltage: 230 V 1 ~ 50 Hz | Max battery capacity: 100 Ah

BATTERIES (2 x TEAxx / xxAh)


Product code GTIN code Size of the battery (Ah) 6,5 Ah 15 Ah 24 Ah 38 Ah 65 Ah 100 Ah 150 Ah Max load, 1 h operation time 80 W 150 W 245 W 415 W 680 W 960 W Max load, 3 h operation time 34 W 70 W 115 W 185 W 305 W 480 W 730 W Battery cabinet TK2300 TK2300 TK2300 TK2300 TK4100 TK2310 TK2310 Battery cable XJ995 XJ996 XJ996 XJ996 XJ996 XJ996 XJ996 Dimensions of the battery (mm) 151 x 65 x 98 181 x 76 x 167 166 x 175 x 125 197 x 165 x 173 350 x 166 x 174 327 x 168 x 210 485 x 172 x 240 Weight of the battery (kg) 2,4 5,9 8,7 13,8 22,8 33,5 47,0

TEA020 TEA021 TEA022 TEA023 TEA024 TEA024B TEA024D

6438045000824 6438045000831 6438045000848 6438045000855 6438045000862 6438045004396 6438045005867

| A 10 % reserve is recommended for the loads (W) mentioned in the table.

BATTERY CABINETS
Product code TK2300 TK2310 TK4100 GTIN code 6438045004112 6438045004129 6438045003443 Battery capacity 2 x 12 V / 38 Ah 2 x 12 V / 150 Ah 2 x 12 V / 65 Ah Weight (kg) 6,3 15,5 10

BATTERY CABLES
Product code XJ995 XJ996 GTIN code 6438045003603 6438045003610 Length of the battery cable (m) 1,5 1,5 For 6,5 Ah batteries 15 Ah batteries

| Please note a peeling reserve in the length of the battery cable

OPTIONAL FEATURES
Product code XWT2341 XWT2342 GTIN code 6438045010304 6438045010311 Product description Switched-Maintained Package for 4 circuits each 120 W Switched-Maintained Package for 8 circuits each 120 W For TK23xx TK23xx

Central monitoring options: TST1811 6438045008790 BCM Interface TK23xx

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

25

CENTRAL BATTERY UNITS / 24 V

TKT31/41xx

EN50171

IP 20

Central battery units in the TKT3122 and TKT41xx series offer simple solutions for supplying a relatively small number of luminaires in a limited area. They are especially suited for small premises and applications where it is desirable to divide the central system into multiple independent regions.

The central battery unit input voltage is 230 VAC. The output voltage is 24 VAC in normal mode and 24 VDC in battery mode. The battery voltage is 24 V, which is achieved by connecting two 12 volt batteries in series. TKT41xx central battery units have, depending on the model, either 8 or 16 output circuits and

TKT3122 central battery unit has 4 output circuits, which can be set to function as maintained or non-maintained in groups of two.

DIMENSIONS

420

244
420

602

602

244

26

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

TYPE OF THE PANEL


Product code GTIN code Max input power (mains) 300 VA 1300 VA 1300 VA Outputs Output circuit Max load, maintained luminaires 250 VA 1050 VA 1050 VA Max total load, 1 h duration 290 W 1370 W 1370 W Space for batteries inside the unit 2 x 12 V / 24 Ah 2 x 12 V / 38 Ah 2 x 12 V / 38 Ah Max battery capacity 24 Ah 100 Ah 100 Ah Weight (kg)

TKT3122 TKT4144 TKT4188

6438045005126 6438045005133 6438045004389

4 x 120 W 8 x 120 W 16 x 120 W

Can be set in steps of two circuits / total 4 circuits: Can be set in steps of two circuits / total 8 circuits: Can be set in steps of two circuits / total 16 circuits: -maintained circuits max 120 W/ circuit -non-maintained circuits max 190 W / circuit

12,5 24,0 24,5

| Output voltage: 24 V | Batteries needed: 2 x 12 V (24 V) | Supply voltage: 230 V 1 ~ 50-60 Hz

BATTERIES (2 x TEAxx / xxAh)


Product code TEA020 TEA021 TEA022 TEA023 TEA024 TEA024B GTIN code Size of the battery (Ah) 6,5 Ah 15 Ah 24 Ah 38 Ah 65 Ah 100 Ah Max load, 1 h operation time 95 W 180 W 290 W 490 W 800 W 1370 W Max load, 3 h operation time 40 W 85 W 135 W 220 W 360 W 565 W Battery cabinet TK2300 TK2300 TK2300 TK2300 TK4100 TK2310 Battery cable XJ995 XJ996 XJ996 XJ996 XJ996 XJ996 Dimensions of the battery (mm) 151 x 65 x 98 181 x 76 x 167 166 x 175 x 125 197 x 165 x 173 350 x 166 x 174 327 x 168 x 210 Weight of the battery (kg) 2,4 5,9 8,7 13,8 22,8 33,5

6438045000824 6438045000831 6438045000848 6438045000855 6438045000862 6438045004396

| A 10 % reserve is recommended for the loads (W) mentioned in the table.

| NOTE! TKT3122 max battery 24 Ah

BATTERY CABINETS
Product code TK2300 TK2310 TK4100 GTIN code 6438045004112 6438045004129 6438045003443 Battery capacity 2 x 12 V / 38 Ah 2 x 12 V / 150 Ah 2 x 12 V / 65 Ah Weight (kg) 6,3 15,5 10,0

BATTERY CABLES
Product code XJ995 XJ996 GTIN code 6438045003603 6438045003610 Length of the battery cable (m) 1,5 1,5 For 6,5 Ah batteries 15 Ah batteries

OPTIONAL FEATURES
Product code XWT3141 XWT4141 XWT4142 GTIN code 6438045010397 6438045010403 6438045010410 Product description Switched-Maintained Package for 4 circuits each 120 W Switched-Maintained Package for 8 circuits each 120 W Switched-Maintained Package for 16 circuits each 120 W For TKT3122 TKT4144 TKT4188

Central monitoring options: TST1811 6438045008790 BCM Interface TKT3122 and TKT41xx

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

27

BATTERY CABINETS, BATTERY CABLES

BATTERY CABINETS
BATTERY CABINETS
Product code TK2300 TK2310 TK4100 TK6500B TKT6500 GTIN code 6438045004112 6438045004129 6438045003443 6438045006284 6438045006819 Battery capacity 2 x 12 V / 38 Ah 2 x 12 V / 150 Ah 2 x 12 V / 65 Ah 18 x 12 V / 15 Ah 6 x 12 V / 100 Ah Weight (kg) 6,3 15,5 10,0 14,0 28,0

IP 20

BATTERY CABINET TK2300


517

BATTERY CABINET TK4100


419

BATTERY CABINET TK2310


533

338

602

705

203

216

299

338

602

705

419
203

533

216
517

299

BATTERY CABINET TKT6500


518 312

BATTERY CABINET TK6500B


553 276

1496

1496

772

772

312 518 276

553

28

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

BATTERY CABLES
| Battery cable is needed with a separate battery cabinet

BATTERY CABLES
Product code XJ995 XJ996 XJ997B XJ997 XJ997C XJ997E XJ997F XJ997G GTIN code 6438045003603 6438045003610 6438045003627 6438045003634 6438045005140 6438045006291 6438045008806 6438045008813 Length of the battery cable (m) 1,5 1,5 1,5 1,5 2,5 3,5 For 6,5 Ah batteries 15 Ah batteries 6,5 Ah batteries 15 Ah batteries For two battery cabinets For three TKT6500 battery cabinets 15 Ah batteries 6,5 Ah batteries For TKT31, TKT41 and TK23 Central battery units TKT31, TKT41 and TK23 Central battery units TKT65 and TKT66 Central battery units TKT65 and TKT66 Central battery units TKT65 and TKT66 Central battery units TKT65 and TKT66 Central battery units TKT68 Central battery units, with batteries 15 Ah TKT68 Central battery units, with batteries 6,5 Ah

| Please note a peeling reserve in the length of the battery cable

references

World Trade Center, Doha, Qatar

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

29

BATTERIES AND BATTERY CAPACITY / BATTERY MODE DURATION, REMOTE SWITCHES, ADDRESS MODULES

BATTERIES
Product code TEA020 TEA021 TEA022 TEA023 TEA024 TEA024B TEA024D GTIN code 6438045000824 6438045000831 6438045000848 6438045000855 6438045000862 6438045004396 6438045005867 Size of the battery (Ah) 6,5 Ah / 12 V 15 Ah / 12 V 24 Ah / 12 V 38 Ah / 12 V 65 Ah / 12 V 100 Ah / 12 V 150 Ah / 12 V Dimensions (mm) 151 x 65 x 98 181 x 76 x 167 166 x 175 x 125 197 x 165 x 173 350 x 166 x 174 327 x 168 x 210 485 x 172 x 240 Weight (kg) 2,4 5,9 8,7 13,8 22,8 33,5 47,0

BATTERY CAPACITY / BATTERY mODE DURATION


| A 10 % reserve is recommended for the loads (W) mentioned in the table.

TKT3122 AND TKT41xx CENTRAL BATTERY UNITS


Battery capacity 2 x 12 v (24 v) TEA020 / 6,5 Ah TEA021 / 15 Ah TEA022 / 24 Ah TEA023 / 38 Ah TEA024 / 65 Ah TEA024B / 100 Ah Max load, 1 h operation time 95 W 180 W 290 W 490 W 800 W 1370 W Max load, 3 h operation time 40 W 85 W 135 W 220 W 360 W 565 W

TK23xx(C) CENTRAL BATTERY UNITS


Battery capacity 2 x 12 v (24 v) TEA020 / 6,5 Ah TEA021 / 15 Ah TEA022 / 24 Ah TEA023 / 38 Ah TEA024 / 65 Ah TEA024B / 100 Ah TEA024D / 150 Ah Max load, 1 h operation time 80 W 150 W 245 W 415 W 680 W 960 W Max load, 3 h operation time 34 W 70 W 115 W 185 W 305 W 480 W 730 W

TKT65xx(C), TKT66xxC AND TKT68xxC CENTRAL BATTERY UNITS


Battery capacity 18 x 12 v (216 v) TEA020 / 6,5 Ah TEA021 / 15 Ah TEA022 / 24 Ah TEA023 / 38 Ah TEA024 / 65 Ah Max load, 1 h operation time 870 W 1700 W 2720 W 4550 W 6000 W Max load, 3 h operation time 350 W 770 W 1250 W 2050 W 3340 W

TKT67xxC CENTRAL BATTERY UNITS


Battery capacity 18 x 12 v (216 v) TEA024 / 65 Ah TEA024B / 100 Ah TEA024D / 150 Ah TEA024C / 200 Ah 300 Ah (2 x 150 Ah) 400 Ah (2 x 200 Ah) Max load, 1 h operation time 7500 W 11780 W 17670 W 19600 W Max load, 3 h operation time 3340 W 5050 W 7580 W 10010 W 15160 W 19600 W

30

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

REmOTE SWITCHES
Product code SK066 SK066C SK065 SK066B GTIN code 6438045003986 6438045005515 6438045003979 6438045005508 Installation Recess mounted, 24 V Recess mounted Collar for surface mounting Glass for remote control For TKT31, TKT41 and TKT65 TKT65, TKT66, TKT67, TKT68 SK066(C) SK066(C)

SEPARATE ADDRESS mODULES


Product code TS98261 TS98263 TS98253 TS98254 TS98255 TS98271 Power 60 W 60 W 100 W 200 W 625 W 200 W Adressesses Max 32 addresses Max 32 addresses Max 32 addresses Max 32 addresses Max 32 addresses Max 32 addresses Maintained / non-maintained Maintained Maintained / non-maintained Maintained / non-maintained Maintained / non-maintained Maintained / non-maintained Maintained / non-maintained Operation can be selected by a dip switch Operation can be selected by a dip switch Operation can be selected by a dip switch Operation can be selected by a dip switch Operation can be selected by a dip switch, DALI compatible dimming in emergency mode 150 x 42 x 32 Feature Dimensions (mm) 98 x 42 x 21 98 x 42 x 21 98 x 42 x 21 150 x 42 x 32

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

31

SWITCH CONTROLLER AND LOCAL CONTROLLER

SWITCH CONTROLLER AND LOCAL CONTROLLER

Switch Controller Utilising the Switch Controller TST28xx, it is possible under normal mode to activate the luminaires connected to the central battery unit using either a light switch or a timer. During an emergency mode, the Switch Controller switches the supply to take place from the central battery unit. In this case, all the luminaires will be lit automatically whether the light switch is on or off. The Switch Controller TST28xxx is compatible with all Teknoware central battery units having a 230 VAC/DC output. It can also be used with the Local Controller.

Local Controller The Local Controller enables local control of emergency lighting luminaires in central battery systems. It monitors the local supply, and controls the emergency luminaires connected to it. Models TS90695, TS90696, TST6803 and TST6804 have a relay output for controlling other devices. The relay output changes status when the Local Controller is activated. Models TS90695, TS90696, TST6803 and TST6804 also have a switch control input and a potentiometer for setting a time delay so that the connected luminaires remain lit after the normal power supply has been restored. Both maintained and non-maintained emergency luminaires can be connected to the same circuit wiring. Teknoware luminaires (when the code ends with a letter K) can be installed as a non-maintained when used with the Local Controller.

SWITCH CONTROLLER TST2800


5,5 60 5,5
5,5

LOCAL CONTROLLER TS90xxx


117 107 5,5 60 60 117 107

117 107

107 117
38 38 117

60

60 117 60
123 5,5

TST68xx
123 107

38

38

TST2802
123 5,5 123 107 5,5

TST2801/ TST2803
213 20 20 213 160 3,5
107 65

86
5,5

86

86

86

127 82 127
43

86

107
123 117 65

213
86

43

127

123

43

43

75

75

32

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

3-phase monitoring

LC mains supply Tapsa Control CBU

3-phase monitoring

Local Controller provides local sub-circuit monitoring

LC

data through the power cables

Battery Cabinet SC Switch Controller provides switching of the luminaires together with the normal lighting

= non-maintained luminaire = maintained exit luminaire SC

SWITCH CONTROLLER
Product code TST2800 TST2801 TST2802 TST2803 GTIN code 6438045006307 6438045006314 6438045007953 6438045007960 Input voltage 230 V 230 V 230 V 230 V Power 250 W 250 W 1400 W 1400 W Installation Inside a distribution panel With the junction box enclosure for independent installation Inside a distribution panel, DIN rail compatible With the junction box enclosure for independent installation

LOCAL CONTROLLER
Product code TS90685 GTIN code 6438045004143 Input voltage 230 V Power 250 W Installation Inside a distribution panel Feature 3-phase monitoring, Controlling the non-maintained luminaires through the supply cabling 3-phase monitoring, Controlling the non-maintained luminaires through the supply cabling 3-phase monitoring, Controlling the non-maintained luminaires through the supply cabling Switch control input, Relay contact output, 1-15 min adjustable delay for return to mains operations 3-phase monitoring, Controlling the non-maintained luminaires through the supply cabling Switch control input, Relay contact output, 1-15 min adjustable delay for return to mains operations 3-phase monitoring, controlling the non-maintained luminaires through the supply cabling 3-phase monitoring, Controlling the non-maintained luminaires through the supply cabling 3-phase monitoring, Switch control input, Relay contact output, 1-15 min adjustable delay for return to mains operations Switch control input, Relay contact output, 1-15 min adjustable delay for return to mains operations

TS90686

6438045006826

230 V

250 W

With the junction box enclosure (IP20) for independent installation Inside a distribution panel

TS90695

6438045006321

230 V

250 W

TS90696

6438045006338

230 V

250 W

With the junction box enclosure (IP20) for independent installation

TST6801

6438045007977

230 V

1400 W

Inside a distribution panel, DIN rail compatible With the junction box enclosure (IP20) for independent installation Inside a distribution panel

TST6802

6438045007984

230 V

1400 W

TST6803

6438045008820

230 V

1400 W

TST6804

6438045008837

230 V

1400 W

With the junction box enclosure (IP20) for independent installation

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

33

Helsinki-Vantaa International Airport, Vantaa, Finland

references

Finnish National Opera, Helsinki, Finland

34

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

INTELLIGENT CONTROLLER (IC)


With Teknowares Intelligent Controller it is possible to switch on any emergency luminaire through any freely selectable voltage input (8 pcs) of the TST8801 control unit. Each voltage input has its own galvanically separated L and N connection. The system consists of max 32 pcs of TST8801 Intelligent Controller units, TST6x5x interface which is installed inside the CBU and the Software which is installed in the PC and used to program the inputs of one or more TST8801 units. The programming of the system and the luminaires is done with a PC through a USB interface in the TST8804 control unit, which is included in the CBU-specific interface package. The luminaire control package can be used with the Teknoware TKT6x Control central battery units and K-type addressable luminaires. Each TST8801 has its individual address which is set with a DIP switch. The system enables the switching on/off of the non-maintained emergency luminaires through the TST8801 inputs. At the same time it is possible to monitor the voltage of several fuse boxes or general lighting. When in one or more fuse box the voltage disappears, the specified emergency luminaires will switch on in AC voltage. The system makes it possible to determine lots of different alternatives to control the non-maintained emergency luminaires on and off with the TST8801 inputs. The system consists of a TST6x Control CBU, addressable luminaires and the following components which are needed in the Intelligent Controller system: -Intelligent Controller TST8801 with 8 voltage inputs (max 32 pcs in one system) -Intelligent Controller interface TS6x5x inside the CBU -TST8851 Intelligent Controller Software, which is used to program the system via a PC (the Software is included in the interface package) The data between the Intelligent Controller and the control interface in the CBU travels through a 2-core data cable. The maximum length of the bus cable is 1 500 m. The data between the Intelligent Controller and the CBU travels through the data bus cable. The system settings are done with a PC Software during the implementation of the system. Any input of any Intelligent Controller can be set to control any luminaire or luminaires in any circuit. Logical switches can be programmed in the system so that the inputs of one TST8801 unit can form groups which can control the luminaires. Logical switches function so that when a switch of any group activates, all luminaires which are programmed in that group will switch on. Individual inputs and logical switches can also be used inverted.
IC IC
Product code TST8801 TST8851 Interface TST6551 TST6552 TST6553 TST6651 TST6652 TST6653 TST6751 TST6752 TST6753 TST6754 TST6755 TST6756 TST6757 TST6851 TST6852 TST6853 Product description Intelligent controller IC PC Software For TKT6508C TKT6516C TKT6524C TKT6608C TKT6616C TKT6624C TKT6708C TKT6716C TKT6724C TKT6732C TKT6740C TKT6748C TKT6756C TKT6808C TKT6816C TKT6824C

| DIN rail compatible.

Intelligent controller with 8 programmable inputs

d
mains supply Tapsa Control CBU 1 2 3

a ta

s bu

us d a ta b

IC

Battery Cabinet

US

PC

= non-maintained luminaire = maintained exit luminaire

PC is used to program the inputs and outputs during the commissioning.

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

35

CENTRAL MONITORING

SWITCHED-mAINTAINED PACKAGE
Switched-Maintained enables the switching on/off of the emergency lighting circuits as maintained or nonmaintained using an external relay or switch. In the addressable central battery units (except TK23xxC) it is possible to switch on/off all the circuits of one circuit board and it is also possible to select the type of control as NO or NC. The mode loops on the circuit boards are replaced with the SwitchedMaintaned unit. In non-addressable central battery units and in TK23xxC one circuit and in TKT31/41 two circuits can be controlled at a time. Switched-Maintained is available as an option for all Teknoware central battery units.
Product code XWT6772 XWT6773 XWT6774 XWT6775 XWT6776 XWT6777 XWT6871 XWT6872 XWT6873 XWT6671 XWT6672 XWT6673 XWT6571C XWT6572C XWT6573C XWT6571 XWT6572 XWT6573 XWT2341 XWT2342 XWT3141 XWT4141 XWT4142 Product description Switched-Maintained Package for 16 circuits each 350 W Switched-Maintained Package for 24 circuits each 350 W Switched-Maintained Package for 32 circuits each 350 W Switched-Maintained Package for 40 circuits each 350 W Switched-Maintained Package for 48 circuits each 350 W Switched-Maintained Package for 56 circuits each 350 W Switched-Maintained Package for 8 circuits each 350 W Switched-Maintained Package for 16 circuits each 350 W Switched-Maintained Package for 24 circuits each 350 W Switched-Maintained Package for 8 circuits each 350 W Switched-Maintained Package for 16 circuits each 350 W Switched-Maintained Package for 24 circuits each 350 W Switched-Maintained Package for 8 circuits each 250 W Switched-Maintained Package for 16 circuits each 250 W Switched-Maintained Package for 24 circuits each 250 W Switched-Maintained Package for 6 circuits each 250 W Switched-Maintained Package for 12 circuits each 250 W Switched-Maintained Package for 18-24 circuits each 250 W Switched-Maintained Package for 4 circuits each 120 W Switched-Maintained Package for 8 circuits each 120 W Switched-Maintained Package for 4 circuits each 120 W Switched-Maintained Package for 8 circuits each 120 W Switched-Maintained Package for 16 circuits each 120 W For TKT6716C TKT6724C TKT6732C TKT6740C TKT6748C TKT6756C TKT6808C TKT6816C TKT6824C TKT6608C TKT6616C TKT6624C TKT6508C TKT6516C TKT6524C TKT6506B TKT6512B TKT6518-24B TK2301(C)-04(C) TK2305(C)-08(C) TKT3122 TKT4144 TKT4188

36

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

WEBCm & WEBACm


WebCM enables central monitoring of the central battery systems via Internet. The system consists of a Web module connected to a central battery unit. Each central battery unit has an individual IP address and an ordinary Internet browser serves as a user interface. The basic system indicates the state of the central battery unit and the luminaires connected to it and displays the test log book information. The user may also run luminaire and battery tests. WebCM is available for the central battery units in the TKT65, TKT66, TKT67 and TKT68 series, which are equipped with addressable monitoring function. WebACM is a user-specific software for WebCM system via Ethernet TCP/IP. User-specific software enables the use of a mapping application which indicates the location of the equipment in the building.
Product code TST5161 Product code TST6724 TST6824 TST6624 TST6524 Product description WebACM Software Product description WebCM/ WebACM Interface WebCM/ WebACM Interface WebCM/ WebACM Interface WebCM/ WebACM Interface For TKT67xxC TKT68xxC TKT66xxC TKT65xxC

mains supply PC
IP P/ C

TCP/IP

Tapsa Control CBU

outputs

Battery Cabinet INTERNET PC


IP P/ TC

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

37

CENTRAL MONITORING

ACm
Teknowares Advanced Central Monitoring (ACM) is a central monitoring system utilising a separate network for the Tapsa Control central battery units. ACM utilises RS485 protocol, which makes communications possible even if the distance between the central battery unit and the computer is up to 1 km. ACMs PC Software screen displays the status of all the central battery units and the luminaires connected to them. The user may also run battery and luminaire tests. ACM saves the test log book information automatically as per the requirements of fire safety authorities. By using the computer equipped with ACM, it is possible to connect, e.g., to a BACnet building automation system

Product code TST5131 TST5141 TST5171

Product description ACM PC Software and modem ACM PC system with BACnet Interface ACM PC system with additional serial output

Product code TST6721 TST6821 TST6621 TST6521

Product description ACM Interface ACM Interface ACM Interface ACM Interface

For TKT67xxC TKT68xxC

TKT65xxC

PC

Central Battery Unit

SB
Modem

/6 T5 CA

CAT 5/6

Central Battery Unit

CAT 5/6

Central Battery Unit

CAT 5/6

TKT66xxC

Central Battery Unit

= non-maintained emergency luminaire = maintained exit luminaire

38

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

BACNET
The BACnet module in the central battery unit allows it to be connected directly to a building automation system. The BACnet application make it possible to access all the information supplied by the central battery unit. In the BACnet interface, information is transferred as BACnet objects. Teknoware uses BACnet modules as an interface to transfer BACnet objects from the central battery units and luminaires. Battery and luminaire tests can also be initiated. PC software can be used to read the information of the central battery units through the BACnet bus.
Product code TST5151 Product description PC Software for BACnet

Product code TST6701 TST6823 TST6601 TST6501

Product description BACnet Interface BACnet Interface BACnet Interface BACnet Interface

For TKT67xxC TKT68xxC TKT66xxC TKT65xxC

6 5/ AT C
N

Central Battery Unit Central Battery Unit Central Battery Unit

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

P/ TC
IP

ET

OR

Ethernet switch
K

CAT 5/6

CAT
T5 CA /6

5/6

Central Battery Unit

= non-maintained emergency luminaire = maintained exit luminaire

39

CENTRAL MONITORING

LON
Product code TST6722 TST6822 TST6622 TST6522 XKT2301 Product description LON Interface LON Interface LON Interface LON Interface LON Interface For TKT67xxC TKT68xxC TKT66xxC TKT65xxC TK23xxC

LON central monitoring solution is based on the COBA Building Operating System, which offers a standard open platform for building automation and security systems. The COBA interface also makes it possible to access all information from the field in a centralised manner. The system consists of an open LON network and a server, which link the central battery units together.

| Also a separate COBA Software is needed for the PC.

PC
SB

Central battery unit


2x
P TC

2C

N LO

LNI

N ET W

2 x 2C LON

Central battery unit

2 x 2C LON

Central battery unit

2 x 2C LON

Central battery unit

IP

= non-maintained emergency luminaire


RK

= maintained exit luminaire

40

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

BCm UNIT
Product code TST1809 TST1809B Product description Basic Central Monitoring Unit with Printer Basic Central Monitoring Unit without Printer Supply voltage 1 ~230 V AC 50 Hz 1 ~230 V AC 50 Hz Casing IP20 IP20 Temperature range +10... 30 C +10... 30 C Input fuse Glass-tube fuse 1 AT 5 x 20mm Glass-tube fuse 1 AT 5 x 20mm

Product code TST1811E TST1811F TST1811D TST1811C TST1811

Product description BCM Interface BCM Interface BCM Interface BCM Interface BCM Interface

For TKT67xxC TKT68xxC TKT66xxC TKT65xxC TK23xx(C), TK65xxB, TKT31/41xx

Basic Central Monitoring unit (BCM) is possible to be connected in all central battery units. There can be Max 9 central battery units per one BCM unit. BCM can be used for monitoring and controlling the following basic functions: - Emergency mode indication - Internal fault indication (fault in the central battery unit itself) - External fault indication (fault in one or several luminaires) - Running battery tests -Running luminaire tests.

319 260 192

260

68

69 130

Central Battery Unit Central Battery Unit

BCM

Central Battery Unit

3-c

ta cable o r e da
Central Battery Unit

= non-maintained emergency luminaire = maintained exit luminaire

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

41

references

Maritime Centre Vellamo, Kotka, Finland

42

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

ExIT AND EmERGENCY LUmINAIRES


CRYSTAL | TWT53 46 ESC 10 | TW802 48 ESC 10 | TW850, TWS85 48 ESC 10 | TW844 50 ESC 10 | TW868, TWS86 52 ESC 20 | TWT46, TWT47, TWT48, TW89 54 ESC 55 | TWT55 56 ESC 6 | TWT60, TWS60 58 ESC 6 L | TWT62, TWS62 60 ESC 4 | TWT17, TWS17 62 SAFE 29 | TWT29, TWS29 64 SAFE 82 | TWT82 68 ESC 0,5 | TW416 72 ESC 1 | TW305 74 ESC 1,5 | TW417 76 ESC 3 | TW397, TW494 78 ESC SECTOR | TW888 80 LEDmAN | TW474 82 ESC CUBE | TWK63 84 SAFE 6 | TWT82 86 LINESPOT | TWT50, TWS50 88 ZONESPOT | TWT64, TWS64 88 SLImSPOT | TWT97, TWS97 90 LINESPOT | TWT78, TWS78 92 ZONESPOT | TWT94, TWS94 94 mINI LINESPOT | TWT73, TWS73 98 TWINSPOT | TWT35 100 SAFESPOT | TWT44, TWS44 102 SAFE 22 | TWT22 106 ON-IN | TW422 110 DOWNLIGHT | TW956 112 TWT58 | TWT58 114 TWK41 / 42 | TWK41, TWK42 116

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

43

EXIT AND EMERGENCY LUMINAIRES

ESCAP SELF-CONTAINED LUmINAIRES

Cutting-edge technology for emergency lighting


For emergency lighting there have been and still are only two basic solutions, both of which are determined by the location of the battery: - Central battery systems, where a central battery bank powers several luminaires - Self-contained systems, where each luminaire has its own battery Each alternative offers certain advantages and disadvantages. Central battery systems offer the advantage of easy testing and maintenance, whereas selfcontained systems offer flexible installations due to simpler cabling. The definitive disadvantage of self-contained systems has been the limited lifespan of batteries. Besides which, the changing of batteries could be very labour intensive as the batteries are located in possibly hundreds of luminaires. Teknoware solves the battery problem of self-contained luminaires by replacing the batteries with ESCAP technology. Using LED luminaires and the wireless Aalto Control remote management system together, it is possible to create a solution where the advantages of both central battery and self-contained systems can be combined and the disadvantages eliminated.

Capacitors replace batteries


ESCAP is self-contained luminaire product line which combines capacitive energy storage with the latest LED technology. Unlike traditional applications, the energy required during a power outage is not stored in traditional electrochemical batteries but in very high capacitance low-voltage capacitors. Capacitors cannot replace batteries directly due to their different voltage characteristics. A capacitors charge voltage and current must be controlled accurately and as wide a relative voltage range as possible must be utilised when the capacitor is discharged. Teknoware has developed special power converter technology to overcome these challenges and as a result, it has been possible to utilise this quickly advancing technology in practical applications.

Maintenance-free service for more than ten years


ESCAP technology makes it possible to manufacture self-contained luminaires which contain no harmful substances and which require no regular battery replacements. Capacitors have a lifespan of over ten years, which matches the life expectancy of modern surface mount LEDs. As a result, the luminaire does not require maintenance during its lifespan. In addition, it does not contain any hazardous waste, so it can be recycled at the time of disposal like any ordinary electronic waste. As an energy source, the capacitor offers the added advantage of having much shorter charge time in comparison to traditional battery technology. As a result, full emergency lighting capacity is restored quickly after a power outage. Environmental Advantages also include the fact that ESCAP luminaires use very little energy because a fully charged capacitor is consuming practically no power at all.

44

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

LUmITEST SELF-TESTING LUmINAIRES


Lumi Test self-diagnosis, which is available for self-contained luminaries, automatically tracks and tests the reliable operation of luminaires. LED indicators (one green and one red one display the status of the luminaires. Red LED indicates fault. Lumi Test is used to track the actual output intensity of LED lights and the emergency mode duration. The luminaire is general functionality and light source are tested daily. Full emergency mode duration is tested every 6 months. Product codes of ESCAP luminaires with selftesting end with letter M.

SELF-TESTING LEDS
INDICATOR-LEDS FUNCTIONALITY
NO SUPPLY OK LOW ENERGY STORAGE LIGHT SOURCE FAULT DURATION TEST FAULT DURATION TEST FAULT AND LIGHT SOURCE FAULT TEST IN PROGRESS

Symbol Key
OFF ON BLINKING FAST BLINKING

AALTO CONTROL SELF-CONTAINED LUmINAIRES


Product code TST5101 Product description Aalto Control complete PC system with software and network coordinator (the system can include up to 1500 luminaires) Wall mounted device for Aalto Control network monitoring (the system can include up to 100 luminaires)

TST5102

Aalto Control provides a wireless central monitoring for self-contained luminaires. There is no need to connect the luminaires with data cables. The only requirement is that each individual luminaire has a local power supply, like any standard self-contained luminaire. All the benefits of the selfcontained luminaires are preserved and each luminaire functions independently. Installation is simple and the luminaires can be easily positioned even during renovations. The network is used only for collecting information and does not affect the operation of the luminaires. For this reason, Aalto Control is as robust and resistant to failures as any other self-contained luminaire system. Aalto Control always includes Lumi Test. Product codes of Aalto Control luminaires end with letter A.

AALTO CONTROL Wireless monitoring for self-contained luminaires

= non-maintained emergency luminaire = maintained exit luminaire

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

45

EXIT AND EMERGENCY LUMINAIRES

CRYSTAL

EN 60598-2-22

EN 1838

-o-

IP 20

26 M vIEWING DISTANCE

CEILING AND WALL MOUNTING AS STANDARD

The Crystal exit luminaire has a unique light plate design which makes this model very attractive. The luminaire is appropriate for ceiling or wall mounting. The luminaire can be used in a single or double face configuration. A separate installation kit is available for flush mounting. Long-lasting LEDs are used as a light source. The exit symbol is printed on a separate plate which can be easily installed from the top in a slot in the middle of the light plate. Because the luminaire is supplied with several alternative exit symbols, the indicated exit direction can be easily changed as needed. The luminaire is double faced but can be changed to single faced by using the white cover plate which is included.
CEILING MOUNTING
293 65

WALL MOUNTING
115 108

RECESS MOUNTING
88 21

41

214

24

149 293 240 108 41 30 37 21 5,5 30 108 78 65 29 128


120 130 5,5 320 287 240

300 21

150

46

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT5341W TWT5351W TWT5351WK GTIN code 6438045007540 6438045007557 6438045007564 viewing distance < 26 m < 26 m < 26 m Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC Input power 4 VA / 5W 12 VA / 7W 8,5 VA / 5W Light source LED LED LED Operation mode CBU CBU CBU / C Temperature range -30+50C -30+50C -30+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 1,0 1,0 1,0

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TWT5353W GTIN code 6438045007588 viewing distance < 26 m Supply voltage 230 V AC Input power 14 VA Light source LED Operation mode 3 h battery Temperature range -5+30C Electrical installation 3 x 2,5 mm2 -oWeight (kg) 2,0

REvERSIBLE PICTOGRAMS INCLUDED IN THE PACKAGE


Product code PBV53262 PBV53261 Label Pictogram Product description Down arrow Left/right arrow White label

ACCESSORIES
Product code TWT5300 GTIN code 6438045008271 Product Recess mounting kit

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

47

EXIT AND EMERGENCY LUMINAIRES

ESC 10

EN 60598-2-22

EN 1838

-o-

IP 20

30 M - 40 M vIEWING DISTANCE

A BRACKET IS ALWAYS NEEDED

The elegant exit luminaire TW802 / TW850 / TWT85 / TWS85 has an extruded aluminium frame and an edge-lighted light plate. By utilising a separate support bracket, it can be ceiling, wall or side mounted, or suspended. The luminaire can be used in a single or double face configuration. The product line consists of models having either a long-life LED or a fluorescent lamp as a light source. The exit symbol is silk screened on the interior side of the light plate. The Esc 10 product line is especially suited for areas requiring truly elegant exit signs.
CEILING MOUNTING TW802xx + TW77501
28 239
68 27

WALL MOUNTING TW802xx + TW77503


76 8 70

FLAG MOUNTING TW802xx + TW77505


369

122

21

324 215 167 68


311

51

30
311 45

326

326

51 33

30

21

33

CEILING MOUNTING TW85xxx + TW77501


28 251 239
68 27

WALL MOUNTING TW85xxx + TW77503


76 8 70
30 51 21
272

FLAG MOUNTING TW85xxx + TW77505


296 45

122

251 215 167 68 30 33

21

287

287

272
33

51

CEILING MOUNTING TWS8592WA/M + TW77501 324


94 259

WALL MOUNTING TW8592WA/M + TW77503


76 8

FLAG MOUNTING TW8592WA/M + TW77505


369 324

272

272

48

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TW85021 TW85041W TW85051W TW85051WK TW85081 TW85081K TW80221 TW80241W TW80251W TW80251WK TW80281 TW80281K GTIN code 6438045004822 6438045006604 6438045006611 6438045006628 6438045004839 6438045005577 6438045000343 6438045006567 6438045006574 6438045006581 6438045000350 6438045002774 viewing distance < 30 m < 30 m < 30 m < 30 m < 30 m < 30 m < 40 m < 40 m < 40 m < 40 m < 40 m < 40 m Supply voltage 24 V AC/DC 24 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V A C/DC 24 V AC/DC 24 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC Input power 9 VA / 8W 2 VA / 2,5 W 8,2 VA / 3,9 W 8,3 VA / 4,6 W 10 VA / 6,5 W 8,5 VA / 6W 10 VA / 9W 2 VA / 2,5 W 9,4 VA / 4,7 W 8,2 VA / 4,6 W 12 VA / 8,5 W 10,5 VA / 8W Light source 6W G5 LED LED LED 6W G5 6W G5 8W G5 LED LED LED 8W G5 8W G5 Operation mode CBU CBU CBU CBU / C CBU CBU / C CBU CBU CBU CBU / C CBU CBU / C Temperature range -10+50C -30+50C -30+50C -30+50C -10+50C -10+50C -10+50C -30+50C -30+50C -30+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o2 x 2,5 mm2 -o2 x 2,5 mm2 -o2 x 2,5 mm2 -o2 x 2,5 mm2 -o2 x 2,5 mm2 -o2 x 2,5 mm2 -oWeight (kg) 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7 1,7

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TW85053W TWT8553WM TW80282 TW80253W TWT8553WA TWS8592W TWS8592WA TWS8592WM GTIN code 6438045006635 6438045008844 6438045000367 6438045006598 6438045007441 6438045006734 6438045007335 6438045007342 viewing distance < 30 m < 30 m < 40 m < 40 m < 30 m < 30 m < 30 m < 30 m Supply voltage 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC Input power 9 VA 9 VA 18 VA 9 VA 9 VA 10 VA 10 VA 10 VA Light source LED LED 8W G5 LED LED LED LED LED Operation mode 3 h battery 3 h battery +M 1 h battery 3 h battery 3 h battery + Aalto 1 h Escap 1 h Escap + Aalto 1 h Escap +M Temperature range -5+30C -5+30C -5+30C -5+30C -5+30C -25+35C -25+35C -25+35C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 2,9 2,9 2,8 2,9 2,9 2,9 2,9 2,9

Escap = Self-contained luminaire with 1 h capacitor backup Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

SEPARATELY ORDERED PICTOGRAMS


Product code PBV10302 PBV10301 XW85020 PBV10402 PBV10401 XW80220 GTIN code 6438045006895 6438045006888 6438045009889 6438045006871 6438045006864 6438045009872 viewing distance < 30 m < 30 m < 30 m < 40 m < 40 m < 40 m Pictogram Product description Down arrow Left/right arrow White cover plate Down arrow Left/right arrow White cover plate = right/left arrow For luminaire TW(S)85xx TW(S)85xx TW(S)85xx TW80xx TW80xx TW80xx TW77505 6438045001234

SEPARATELY ORDERED BRACKETS


Product code TW77501 TW77503 TW77504 GTIN code 6438045000145 6438045000152 6438045001241 Product Ceiling bracket Wall bracket Suspension bracket Flag bracket

| Pictograms in the table are always 2-sided, e.g.

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

49

EXIT AND EMERGENCY LUMINAIRES

ESC 10

EN 60598-2-22

EN 1838

-o-

IP 20

30 M vIEWING DISTANCE

WALL MOUNTING ONLY

The elegant exit luminaire TW844 has a frame of sheet metal and extruded aluminium with an edge-lighted light plate. It is appropriate for wall installation. The product line consists of models having either a long-life LED or a fluorescent lamp as a light source. The exit symbol is silk screened on the interior side of the light plate. The Esc 10 product line is especially suited for areas requiring truly elegant exit signs.

DIMENSIONS

277 52

6 41

21

277 265 30 52

95

71 219 219 219

50

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TW84421 TW84441W TW84451W TW84451WK TW84481 TW84481K GTIN code 6438045000374 6438045006642 6438045006659 6438045006666 6438045000381 6438045002781 viewing distance < 30 m < 30 m < 30 m < 30 m < 30 m < 30 m Supply voltage 24 V AC/DC 24 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC Input power 9 VA / 8W 2 VA / 2,5 W 8,2 VA / 3,9 W 8,3 VA / 4,6 W 10 VA / 6,5 W 8,5 VA / 6W Light source 6W G5 LED LED LED 6W G5 6W G5 Operation mode CBU CBU CBU CBU / C CBU CBU / C Temperature range -10+50C -30+50C -30+50C -30+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 1,2 1,2 1,2 1,2 1,2 1,2

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SEPARATELY ORDERED PICTOGRAMS


Product code PBV10302 PBV10301 PB026B GTIN code 6438045006895 6438045006888 6438045002071 Pictogram Product description Down arrow Left/right arrow White label = right/left arrow

| Pictograms in the table are always 2-sided, e.g.

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

51

EXIT AND EMERGENCY LUMINAIRES

ESC 10

EN 60598-2-22

EN 1838

-o-

IP 20

30 M vIEWING DISTANCE

RECESS MOUNTING ONLY

The recess exit luminaire TW868 has an edge-lighted light plate. The luminaire can be used in a single or double face configuration. The product line consists of models having either long-life LEDs or a fluorescent lamp as a light source. The exit symbol is silk screened on the interior side of the light plate. The Esc 10 product line is especially suited for areas requiring truly elegant exit signs.

DIMENSIONS Centrally supplied luminaires


295 265 83 6 83 6 6 72 38 72 62

295 279

254

DIMENSIONS Self-contained luminaires


268 242 74 113 75 74 169 136 268 200

246

246

52

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TW86821 TW86841W TW86851W TW86851WK GTIN code 6438045000404 6438045006673 6438045006680 6438045006697 viewing distance < 30 m < 30 m < 30 m < 30 m Supply voltage 24 V AC/DC 24 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC Input power 9 VA / 8W 2 VA / 2,5 W 8,2 VA / 3,9 W 8,3 VA / 4,6 W 10 VA / 6,5 W 8,5 VA / 6W Light source 6W G5 LED LED LED 6W G5 6W G5 Operation mode CBU CBU CBU CBU / C CBU CBU / C Temperature range -10+50C -30+50C -30+50C -30+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 1,7 1,7 1,7 1,7 1,7 1,7

6438045000411 < 30 | TW86881 in the table are SLIM models m Luminaires TW86881K 6438045002798 < 30 m

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TW86853W TW86882 TWS8692W TWS8692WA TWS8692WM GTIN code 6438045006703 6438045000428 6438045008103 6438045008110 6438045008127 viewing distance < 30 m < 30 m < 30 m < 30 m < 30 m Supply voltage 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC Input power 9 VA 18 VA 10 VA 10 VA 10 VA Light souce LED 6W G5 LED LED LED Operation mode 3 h battery 1 h battery 1 h Escap 1 h Escap + Aalto 1 h Escap +M Temperature range -5+30C -5+30C -25+35C -25+35C -25+35C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 2,9 2,8 2,9 2,9 2,9

Escap = Self-contained luminaire with 1 h capacitor backup Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

SEPARATELY ORDERED PICTOGRAMS


Product code PBV10302U PBV10301U XW86130 GTIN code 6438045006918 6438045006901 6438045009896 Pictogram Product description Down arrow Left/right arrow White cover plate = right/left arrow

| Pictograms in the table are always 2-sided, e.g.

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

53

EXIT AND EMERGENCY LUMINAIRES

ESC 20 LED

EN 60598-2-22

EN 1838

-o-

IP 20

20 - 40 M vIEWING DISTANCE

CEILING AND WALL MOUNTING AS STANDARD

The elegant exit luminaire models of the Esc 20 product line have sheet metal and extruded aluminium frames for wall and ceiling mounting. They have edge-lighted light plates. The luminaire can be used in a single or double face configuration. Longlasting LEDs are used as a light source. The exit symbol is silk screened on the surface of the light plate. The Esc 20 product line is especially suited for areas requiring a simple yet stylish appearance.
TWT46xx

164

21 6

164 145

73
15 29 21

58

158

158

29

34

52 27

158

TWT47xx
204 58 187

21

204 165
15 43

29 42

21 43

83

6 187

29
35

187

TWT48xx
305 58 6 29 257 257 21

305 280 29 21 44

83

16

43

42 35

257

54

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT4641W TWT4651W TWT4741W TWT4751W TWT4751WK TWT4841W TWT4851W TWT4851WK GTIN code 6438045007076 6438045007083 6438045007090 6438045007106 6438045007113 6438045007120 6438045007137 6438045007144 viewing distance < 20 m < 20 m < 26 m < 26 m < 26 m < 40 m < 40 m < 40 m Supply voltage 24 V AC/DC 230 V AC/DC 24 V AC/DC 230 V AC/DC 230 V AC/DC 24 V AC/DC 230 V AC/DC 230 V AC/DC Input power 1,5 VA / 2W 7,4 VA / 3,2 W 2 VA / 2,5 W 8,2 VA / 3,9 W 8,3 VA / 4,6 W 2,5 VA / 3W 9,4 VA / 4,7 W 8,2 VA / 4,6 W Light source LED LED LED LED LED LED LED LED Operation mode CBU CBU CBU CBU CBU / C CBU CBU Temperature range -30+50C -30+50C -30+50C -30+50C -30+50C -30+50C -30+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o2 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,7 0,7 0,8 0,9 1,2 1,3 1,3

CBU = Centrally supplied 1,3 CBU / C -30+50C 3 x 2,5 mm2 C = Compatible with the Tapsa Control central battery unit -o-

SELF-CONTAINED LUMINAIRES
Product code TW89053W TW89153W GTIN code 6438045002583 6438045002590 viewing distance < 26 m < 40 m Supply voltage 230 V AC 230 V AC Input power 9 VA 9 VA Light source LED LED Operation mode 3 h battery 3 h battery Temperature range -5+30C -5+30C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 2,0 2,0
DIMENSIONS TW89153W
65
318
65

SEPARATELY ORDERED PICTOGRAMS


Product code PBV20202 PBV20201 PB026B PBV20262 PBV20261 PB026B PBV20402 PBV20401 PB029 GTIN code 6438045006932 6438045006925 6438045002071 6438045006956 6438045006949 6438045002071 6438045006970 6438045006963 6438045002101 viewing distance < 20 m < 20 m < 20 m < 26 m < 26 m < 26 m < 40 m < 40 m < 40 m Pictogram Product description Down arrow Left/right arrow White label Down arrow Left/right arrow White label Down arrow Left/right arrow White label = right/left arrow For luminaire TWT46xx
246

DIMENSIONS TW89053W
219

TWT46xx TWT46xx
3,5

246

316

316

158 28 85 21
219 28

22
3,5

66

TWT47xx TWT47xx

318 180 28

22

64 5,5

21

12 65 21 85 21 5,5

5,5

21

21

3,5

21

142

318 28

21

TWT47xx
190

TWT48xx TWT48xx TWT48xx

259

| Pictograms in the table are always 2-sided, e.g.

ACCESSORIES
Product code TW77504B TW77506B TWT4601 TWT4601B TW77506C TWT4701 TWT4701B TW77506D TWT4801 TWT4801B GTIN code 6438045006093 6438045007151 6438045007182 6438045009414 6438045007168 6438045007199 6438045009421 6438045007175 6438045007205 6438045009438 Product Suspension bracket Flag bracket Recess mounting frame, grey, RAL9006 Recess mounting frame, white, RAL9010 Flag bracket Recess mounting frame, grey, RAL9006 Recess mounting frame, white, RAL9010 Flag bracket Recess mounting frame, grey, RAL9006 Recess mounting frame, white, RAL9010 For luminaire TWT46xx, TWT47xx, TWT48xx

RECESS MOUNTING FRAME TWT4601


5 182 160

SUSPENSION BRACKET
135

5,5

85 43 115

TWT46xx TWT46xx TWT46xx TWT47xx TWT47xx TWT47xx TWT48xx TWT48xx TWT48xx


5

112

TWT4701
5 220 190

Max. 1000mm 43

145 120
179

57

TWT4801
323 295

145 120

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

55

EXIT AND EMERGENCY LUMINAIRES

ESC 55

EN 60598-2-22

EN 1838

-o-

IP 44

30 M vIEWING DISTANCE

CEILING, WALL AND FLAG MOUNTING AS STANDARD

The elegant exit luminaire TWT55 has a plastic frame and an edge-lighted face plate. It can be ceiling, wall or side mounted, or suspended. Long-lasting LEDs are used as a light source. The exit symbol is silk screened on the surface of the light plate. As the exit luminaires in the TWT55 product line are protected against splashing water, they are also suited for installations in wet areas and in parking garages, outdoor shelters, etc.

CEILING / WALL MOUNTING


271

FLAG MOUNTING
79 65
281

14

234

246

63

18

21

18

23

124

56

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT5541W TWT5551W TWT5551WK GTIN code 6438045007922 6438045007939 6438045007946 viewing distance < 30 m < 30 m < 30 m Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC Input power 2 VA / 2,5 W 8,2 VA / 3,9 W 8,3 VA / 4,6 W Light source LED LED LED Operation mode CBU CBU CBU / C Temperature range -30+50C -30+50C -30+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,5 0,5 0,6

| Luminaires in the table are double insulated

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SEPARATELY ORDERED PICTOGRAMS


Product code PBV55302 PBV55301 PB026B GTIN code 6438045007991 6438045008004 6438045002071 Pictogram Product description Down arrow Left/right arrow White label = right/left arrow

| Pictograms in the table are always 2-sided, e.g.

ACCESSORIES
Product code TW77504B TWT6001 GTIN code 6438045006093 6438045006550 Product Suspension bracket Recess mounting frame
RECESS INSTALLATION FRAME TWT6001 302 72 279 5
109 81 268 58

SUSPENSION BRACKET TW77504B


5,5 85 115 43 Max. 1000mm 43 256 57

66

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

57

EXIT AND EMERGENCY LUMINAIRES

ESC 6

EN 60598-2-22

EN 1838

-o-

IP 44

22 M vIEWING DISTANCE

CEILING. WALL AND FLAG MOUNTING AS STANDARD

The elegant exit luminaire Esc 6 has a plastic frame and can be ceiling, wall or side mounted, or suspended. The luminaire can be used in a single or double face configuration. The product line consists of models having either a long-life LED or a fluorescent lamp as a light source. As the exit luminaires in the Esc 6 product line are protected against splashing water, they are also suited for installations in wet areas and in parking garages, outdoor shelters, etc.

CEILING MOUNTING

WALL MOUNTING

FLAG MOUNTING

121

267 24

20 65

79 17

281

14

21 193 193 205

18

21

18

23

63

124
63 31 20

21

193

58

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT6021 TWT6041 W TWT6081 TWT6081K TWT6071W TWT6071WS TWT6051WK TWT6051WKS GTIN code 6438045005195 6438045008851 6438045005201 6438045005591 6438045005225 6438045007533 6438045005850 6438045009711 viewing distance < 22 m < 22 m < 22 m < 22 m < 22 m < 22 m < 22 m < 22 m Supply voltage 24 V AC/DC 24 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC Input power 9 VA / 8 W 2 VA / 2,5 W 10 VA / 6,5 W 8,5 VA / 6 W 24 V= 7,5 VA / 4 W 230 V= 11 VA / 4 W 24 V= 7,5 VA / 4 W 230 V= 11 VA / 4 W 10 VA / 5,5 W 10 VA / 5,5 W Light source 6W G5 LED 6W G5 6W G5 LED LED LED LED Operation mode CBU CBU CBU CBU / C CBU CBU CBU / C CBU / C Temperature range -10+50C -30+50C -10+50C -10+50C -30+50C -30+50C -30+50C -30+50C Electrical installation 2 x 2,5 mm2 -o2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3 x 2,5 mm2 -o3/2 x 2,5 mm2 -oWeight (kg) 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8

| S-letter at the end of the product code = double insulated

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TWT6082 TWT6052W TWT6052WS TWT6053WA TWS6092W TWS6092WA TWS6092WM GTIN code 6438045005218 6438045005232 6438045008134 6438045007434 6438045006727 6438045007281 6438045007298 viewing distance < 22 m < 22 m < 22 m < 22 m < 22 m < 22 m < 22 m Supply voltage 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC Input power 18 VA 9 VA 9 VA 9 VA 10 VA 10 VA 10 VA LED 6W G5 LED LED LED LED LED LED Operation mode 1 h battery 1 h battery 1 h battery 3 h battery + Aalto 1 h Escap 1 h Escap + Aalto 1 h Escap +M Temperature range -5+30C -5+30C -5+30C -5+30C -25+35C -25+35C -25+35C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 1,9 1,5 1,5 1,5 1,5 1,5 1,5

| S-letter at the end of the product code = double insulated

Escap = Self-contained luminaire with 1 h capacitor backup Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

SEPARATELY ORDERED PICTOGRAMS


Product code PB044 PB046 PB045 PB047 PB026 PB026B GTIN code 6438045005362 6438045005386 6438045005379 6438045005393 6438045001753 6438045002071 Pictogram Product description Down arrow Right arrow Left arrow Multifunction Grey label White label
RECESS INSTALLATION FRAME TWT6001 302 72 279 5
109 81 58 268

SUSPENSION BRACKET TW77504B

5,5

85

115 43 Max. 1000mm 43 57


66

| Pictograms in the table are 1-sided

ACCESSORIES
Product code TW77504B TWT6001 GTIN code 6438045006093 6438045006550 Product Suspension bracket Recess mounting frame

214
6

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

59

EXIT AND EMERGENCY LUMINAIRES

ESC 6L

EN 60598-2-22

EN 1838

-o-

IP 44

40 M vIEWING DISTANCE

WALL AND CEILING MOUNTING AS STANDARD

The elegant exit luminaire Esc 6 has a plastic and metal frame and can be ceiling, wall or side mounted, or suspended. The luminaire can be used in a single or double face configuration. The product line consists of models having either a long-life LED or a fluorescent lamp as a light source. As the exit luminaires in the Esc 6L product line are protected against splashing water, they are also suited for installations in wet areas and in parking garages, outdoor shelters, etc.

CEILING MOUNTING

FLAG MOUNTING XWT6213


75
462

455

295

295

21 75

455 404 30 37

4,5 40

60

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT6221 TWT6281 TWT6281K TWT6271W TWT6251WK GTIN code 6438045005881 6438045005898 6438045005904 6438045005911 6438045005928 viewing distance < 40 m < 40 m < 40 m < 40 m < 40 m Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC Input power 10 VA / 9 W 12 VA / 8,5 W 10,5 VA / 8 W 24 V= 9 VA / 8 W 230 V= 15 VA / 6,5 W 12,5 VA / 7,5 W Light source 8W G5 8W G5 8W G5 LED LED Operation mode CBU CBU CBU / C CBU CBU / C Temperature range -10+50C -10+50C -10+50C -30+50C -30+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 1,5 1,5 1,5 1,6 1,6

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TWT6282 TWT6252W TWS6292W TWS6292WA TWS6292WM GTIN code 6438045005935 6438045005942 6438045007304 6438045007311 6438045007328 viewing distance < 40 m < 40 m < 40 m < 40 m < 40 m Supply voltage 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC Input power 18 VA 18 VA 23 VA 23 VA 23 VA Light source 8W G5 LED LED LED LED Operation mode 1 h battery 1 h battery 1 h Escap 1 h Escap + Aalto 1 h Escap +M Temperature range -5+30C -5+30C -25+35C -25+35C -25+35C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 3,0 3,0 3,0 3,0 3,0

Escap = Self-contained luminaire with 1 h capacitor backup Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

SEPARATELY ORDERED PICTOGRAMS


Product code PB171B PB168B PB158B PB103 PB027 GTIN code 6438045001876 6438045001869 6438045001852 6438045001357 6438045002088 Pictogram Product description Down arrow Right arrow Left arrow Multifunction Grey label

| Pictograms in the table are 1-sided

SUSPENSION BRACKET TWT6200 85 5,5


115

SUSPENSION BRACKET XWT6217

43 Max. 1000mm 380 420 57 341 57

ACCESSORIES
Product code TWT6200 TWS6200 XWT6217 XWT6213 GTIN code 6438045006802 6438045008301 6438045006857 6438045006543 Product Suspension bracket, TWT62xx Suspension bracket, TWS62xx Suspension bracket for cable / chain Flag bracket

5,5

330 310 380 341

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

61

EXIT AND EMERGENCY LUMINAIRES

ESC 4

EN 60598-2-22

EN 1838

-o-

IP 44

24 M vIEWING DISTANCE

CEILING AND WALL MOUNTING AS STANDARD

The elegant exit luminaire Esc 4 has a plastic frame for ceiling and wall mounting. Longlasting LEDs are used as a light source. As the luminaires in the Esc 4 product line are protected against splashing water, they are also suited for installations in wet areas and in parking garages, outdoor shelters, etc.

DIMENSIONS

FLAG MOUNTING

256

22

26

21

261

146

79

76

21

74

146

20

26

62

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT1771W TWT1771WS TWT1751WK TWT1751WKS GTIN code 6438045005171 6438045007526 6438045005584 6438045009728 viewing distance < 24 m < 24 m < 24 m < 24 m Supply voltage 24-230 V AC/DC 24-230 V AC/DC 230 V AC/DC 230 V AC/DC Input power 24 V= 7,5 VA / 4 W 230 V= 11 VA / 4 W 25 V= 7,5 VA / 4 W 230 V= 11 VA / 4 W 10 VA / 5,5 W 10 VA / 5,5 W Light source LED LED LED LED Operation mode CBU CBU CBU CBU Temperature range -30+50C -30+50C -30+50C -30+50C Electrical installation 3 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3 x 2,5 mm2 -o3/2 x 2,5 mm2 -oWeight (kg) 0,5 0,5 0,5 0,5

| S-letter at the end of the product code = double insulated

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TWT1752W TWT1752WS TWT1753WA TWS1792W TWS1792WA TWS1792WM GTIN code 6438045005188 6438045009735 6438045007427 6438045006710 6438045007267 6438045007274 viewing distance < 24 m < 24 m < 24 m < 24 m < 24 m < 24 m Supply voltage 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC Input power 9 VA 9 VA 9 VA 10 VA 10 VA 10 VA Light source LED LED LED LED LED LED Operation mode 1 h battery 1 h battery 3 h battery + Aalto 1 h Escap 1 h Escap + Aalto 1 h Escap +M Temperature range -5+30C -5+30C -5+30C -25+35C -25+35C -25+35C Electrical installation 3 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,8 0,8 0,8 0,8 0,8 0,8

| S-letter at the end of the product code = double insulated

Escap = Self-contained luminaire with 1 h capacitor backup Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

SEPARATELY ORDERED PICTOGRAMS


Product code PB040 PB042 PB041 PB043 GTIN code 6438045005324 6438045005348 6438045005331 6438045005355 Pictogram Product description Down arrow Right arrow Left arrow Multifunction
SUSPENSION BRACKET TW77504B
5,5 85 115 43

| Pictograms in the table are 1-sided

ACCESSORIES
Product code XWT1700 TW77504B XWT1702 GTIN code 6438045005607 6438045006093 6438045006536 Product Flag bracket Suspension bracket Back plate (grey) for TWT17xx
173

Max. 1000mm 57

43

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

63

EXIT AND EMERGENCY LUMINAIRES

SAFE 29

NE

C 92WA WS2992WAB T 9 T WS 2

E 29 W SAF

P RO D

UCT S

EN 60598-2-22

EN 1838

-o-

IP 65

30 M vIEWING DISTANCE

WALL, AND SURFACE MOUNTING AS STANDARD

CAN BE USED AS AN EXIT OR AN EMERGENCY LUMINAIRE

The Safe 29 is suited for demanding environmental conditions. It has a plastic frame and can be used as an exit or an emergency luminaire. As an exit luminaire, it is suited for wall mounting. It combines elegant design with a high protection rating. For emergency luminaire applications, an 18 W model is also available which allows a higher mounting height. The double insulated construction material is shock resistant plastic. The luminaire is available with either a long-life LEDs or a fluorescent lamp. The luminaires in the Safe 29 product line are suited for interior and exterior applications. Thanks to the improved LED technology the new ESCAP models are now available, offering longer mounting distance for both open area (TWS2992WAC) and escape routes (TWS2992WAB). With these new models also 4 m mounting height is now possible.
DIMENSIONS RECESS MOUNTING WITH A SEPARATE FRAME

341

aperture for recess mounting 350 mm x 215 mm

189

94

53

70

341 270 21 189 80

24 398

32
246

64

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT2921 TWT2924 *) TWT2951WK TWT2971W TWT2981 TWT2981K TWT2984 *) TWT2984K *) GTIN code 6438045006345 6438045006352 6438045006369 6438045006376 6438045006383 6438045006390 6438045006406 6438045006413 viewing distance < 30 m < 30 m < 30 m < 30 m < 30 m < 30 m Supply voltage 24 V AC/DC 24 V AC/DC 230 V AC/DC 24 - 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC Input power 9 VA / 11 W 26 VA / 18 W 12,5 VA / 7,5 W 24 V=9 VA /8 W 230 V=15 VA /6,5 W 12 VA / 9 W 11 VA / 8 W 22 VA / 18 W 22 VA / 18 W Light source 9W 2G7 18 W 2G11 LED LED 9W 2G7 9W 2G7 18 W 2G11 18 W 2G11 Operation mode CBU CBU CBU / C CBU CBU CBU / C CBU CBU / C Temperature range -10+50C -10+50C -30+50C -30+50C -10+50C -10+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -oWeight (kg) 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2

| Luminaires in the table are double insulated | *) Luminaire can be used only as emergency luminaire

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TWT2952W GTIN code 6438045006437 viewing distance < 30 m Supply voltage 230 V AC Input power 18 VA Light source LED Operation mode 1 h battery Temperature range maintained -5+30C non-maintained 0 +35C maintained -5+30C non-maintained 0 +35C maintained -5+30C non-maintained 0 +35C maintained -5+30C non-maintained 0 +35C -25+35C -25+35C -25+35C -25+35C -25+35C Electrical installation 3/2 x 2,5 mm2 -oWeight (kg) 1,5

TWT2953W

6438045006444

< 30 m

230 V AC

19,5 VA

LED

3 h battery

3/2 x 2,5 mm2 -o-

1,5

TWT2982

6438045006451

< 30 m

230 V AC

18 VA

9W 2G7

1 h battery

4/3/2 x 2,5 mm2 -o-

1,5

TWT2983

6438045006468

< 30 m

230 V AC

19 VA

9W 2G7

3 h battery

4/3/2 x 2,5 mm2 -o-

1,5

TWS2992W **) TWS2992WA **) TWS2992WM **)

6438045007359 6438045007366 6438045007373 6438045010496 6438045010502

< 30 m < 30 m < 30 m -

230 V AC 230 V AC 230 V AC 230 V AC 230 V AC

23 VA 23 VA 23 VA 3,6 VA 3,6 VA

LED LED LED LED LED

1 h Escap 1 h Escap + Aalto 1 h Escap +M 1 h Escap + Aalto 1 h Escap + Aalto

3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o-

1,5 1,5 1,5 1,5 1,5

NE W NE W

TWS2992WAC *) TWS2992WAB *)

| Luminaires in the table are double insulated, except for Escap types. | *) Luminaire can be used only as emergency luminaire | **) Luminaire can be used only as exit luminaire

Escap = Self-contained luminaire with 1 h capacitor backup Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

65

EXIT AND EMERGENCY LUMINAIRES

SAFE 29
SEPARATELY ORDERED PICTOGRAMS
Product code PB048 PB038 PB039 GTIN code 6438045006475 6438045006499 6438045006482 Pictogram Down arrow Right arrow Left arrow

EN 60598-2-22

EN 1838

-o-

IP 65

Product description

| Pictograms in the table are 1-sided

ACCESSORIES
Product code TWT2900 XWT2904 TWT2901 GTIN code 6438045006505 6438045006529 Product Recess mounting frame Ceiling bracket for one or two luminaire(s) Wall mounting reflector

5,5

CEILING BRACKET XWT2904


317 390 47
390

180
208

60

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWT2921, TWT2981, TWT2981K

TWT2921, TWT2981, TWT2981K

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 13 15

R4 (m) 1 lux 3 3

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 12 14

R3 (m) 0,5 lux 6 8

R4 (m) 0,5 lux 3,5 4,5

2,5 4

14 5

5 6

2,5 4

14 5

6,5 7,5

TWT2924, TWT2984, TWT2984K

TWT2924, TWT2984, TWT2984K

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 16 20 22 11

R4 (m) 1 lux 4,5 5 5,5 4,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 12 16 18 20

R3 (m) 0,5 lux 10 10 10 10

R4 (m) 0,5 lux 5,5 5,5 5,5 5,5

2,5 4 6 8

34 13 6 3,4

7 8 8,5 8

2,5 4 6 8

34 13 6 3,4

6,5 8,5 9,5 10,5

66

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

Emergency lighting for escape routes (ceiling mounting)


| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWT2982

TWT2982

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 7

R4 (m) 1 lux 1,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 6

R3 (m) 0,5 lux 4

R4 (m) 0,5 lux 2,5

2,5

3,5

2,5

2,5

3,5

3,5

TWT2983

TWT2983

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 7

R4 (m) 1 lux 1,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 6

R3 (m) 0,5 lux 4

R4 (m) 0,5 lux 2,5

2,5

2,8

2,5

2,5

2,8

3,5

TWT2951WK, TWT2971W

TWT2951WK, TWT2971W

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 5

R4 (m) 1 lux 2

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 4

R3 (m) 0,5 lux 4

R4 (m) 0,5 lux 2,5

2,5

1,5

2,5

2,5

TWT2952W, TWT2953W

TWT2952W, TWT2953W

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 4

R4 (m) 1 lux 2

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 4

R3 (m) 0,5 lux 4

R4 (m) 0,5 lux 2,5

2,5

1,5

2,5

2,5

TWS2992WAB

TWS2992WAC

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 10 14

R4 (m) 1 lux 2 2

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 10 12

R3 (m) 0,5 lux 4 4

R4 (m) 0,5 lux 7 6

2,5 4

3,2 1,25

4,5 6,5

2,5 3,3

1,8 0,9

5,5 6,5

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

67

EXIT AND EMERGENCY LUMINAIRES

SAFE 82

EN 60598-2-22

EN 1838

-o-

IP 44

20 M vIEWING DISTANCE

CEILING AND WALL MOUNTING AS STANDARD

CAN BE USED AS AN EXIT OR AN EMERGENCY LUMINAIRE

The luminaire Safe 82 has a plastic frame and can be used as an exit or an emergency luminaire. As an exit luminaire, it is suited for wall mounting. The design makes installation possible in places where vertical space is limited. Illumination is provided by a fluorescent lamp. As the luminaires in the Safe 82 product line are protected against splashing water, they are also suited for installations in wet areas and in parking garages, outdoor shelters, etc.

DIMENSIONS

350

125
125
93 86

93
350

160

60

68

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT8222 TWT8224 TWT8281 TWT8281K TWT8284 TWT8284K GTIN code 6438045008325 6438045008332 6438045008349 6438045008356 6438045008363 6438045008370 viewing distance < 20 m < 20 m < 20 m < 20 m < 20 m < 20 m Supply voltage 24 V AC/DC 24 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC Input power 9 VA / 11 W 26 VA / 18 W 12 VA / 9W 11 VA / 8W 22 VA / 18 W 22 VA / 18 W Light source 9W 2G7 18 W 2G11 9W 2G7 9W 2G7 18 W 2G11 18 W 2G11 Operation mode CBU CBU CBU CBU / C CBU CBU / C Temperature range -10+50C -10+50C -10+50C -10+50C -10+50C -10+50C Electrical installation 3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -oWeight (kg) 0,9 0,9 0,9 0,9 0,9 0,9

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TWT8282 GTIN code 6438045008387 viewing distance < 20 m Supply voltage 230 V AC Input power 18 VA Light source 9W 2G7 Operation mode 1 h battery Temperature range maintained -5+30C non-maintained 0 +35C maintained -5+30C non-maintained 0 +35C Electrical installation 4/3/2 x 2,5 mm2 -oWeight (kg) 1,4

TWT8283

6438045008394

< 20 m

230 V AC

19 VA

9W 2G7

3 h battery

4/3/2 x 2,5 mm2 -o-

1,4

SEPARATELY ORDERED PICTOGRAMS


Product code PB0823 PB0821 PB0822 GTIN code 6438045009643 6438045009650 6438045009667 Pictogram Product description Down arrow Right arrow Left arrow

| Pictograms in the table are 1-sided

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

69

EXIT AND EMERGENCY LUMINAIRES

SAFE 82
LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

EN 60598-2-22

EN 1838

-o-

IP 44

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWT8281

TWT8281

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 12 16 17

R4 (m) 1 lux 5,2 6 6

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 10 14 14

R3 (m) 0,5 lux 7 8 10

R4 (m) 0,5 lux 6,5 8 7,5

2,5 4 6

14 5,5 2,4

5,2 6 6

2,5 4 6

14 5,5 2,4

6,5 8 7,5

TWT8284,TWT8284K

TWT8284,TWT8284K

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 16 16 20 21

R4 (m) 1 lux 6 6 8 8

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 14 14 16 17

R3 (m) 0,5 lux 8 8 12 13

R4 (m) 0,5 lux 8,5 8,5 9,5 10,5

2,5 4 6 8

32 12,5 5,6 3,1

6 6 8 8

2,5 4 6 8

32 12,5 5,6 3,1

8,5 8,5 9,5 10,5

TWT8282

TWT8282

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 8

R4 (m) 1 lux 3

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 8

R3 (m) 0,5 lux 4

R4 (m) 0,5 lux 4,5

2,5

3,5

2,5

3,5

4,5

TWT8283

TWT8283

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 8

R4 (m) 1 lux 3

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 8

R3 (m) 0,5 lux 4

R4 (m) 0,5 lux 4,5

2,5

2,8

2,5

2,8

4,5

70

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

references

Crystal Palace, Ljubljana, Slovenia

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

71

EXIT AND EMERGENCY LUMINAIRES

ESC 0,5

EN 60598-2-22

EN 1838

-o-

IP 20

20 M vIEWING DISTANCE

WALL MOUNTING AS STANDARD

The wall mount exit luminaire Esc 0,5 has a metal and plastic frame. The product line consists of models having either a long-life LED or a fluorescent lamp as a light source. The compact size of the Esc 0,5 makes installation possible especially in places where vertical space is limited.

DIMENSIONS

204

67

150

123

75

72

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TW41621 TW41681 TW41681K TW41641W TW41671W TW41651WK GTIN code 6438045000077 6438045000701 6438045002682 6438045001111 6438045007014 6438045006017 viewing distance < 20 m < 20 m < 20 m < 20 m < 20 m < 20 m Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC 24 V AC/DC 24-230 V AC/DC 230 V AC/DC Input power 7 VA / 7 W 7,5 VA / 4,5 W 7 VA / 4 W 2 VA / 2,5 W 24 V=7,5 VA /4 W 230 V=11 VA /4 W 10 VA / 5,5 W Light source 4W G5 4W G5 4W G5 LED LED LED Operation mode CBU CBU CBU / C CBU CBU CBU / C Temperature range -10+50C -10+50C -10+50C -30+50C -30+50C -30+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,8 0,8 0,8 0,8 0,8 0,8

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SEPARATELY ORDERED PICTOGRAMS


Product code PB4171B PB4162B PB4161B PB101 GTIN code 6438045001784 6438045001777 6438045001760 6438045001333 Pictogram Product description Down arrow Right arrow Left arrow Multifunction

| Pictograms in the table are 1-sided

ACCESSORIES
Product code TW30520 TW41620 TW41630 GTIN code 6438045001180 6438045001210 6438045000176 Product Flag bracket Ceiling bracket for two luminaires Ceiling bracket for one luminaire

FLAG BRACKET TW30520


100

CEILING BRACKET TW41620

CEILING BRACKET TW41630

200

200

50
50

50

190

122

122

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

73

EXIT AND EMERGENCY LUMINAIRES

ESC 1

EN 60598-2-22

EN 1838

-o-

IP 20

40 M vIEWING DISTANCE

WALL MOUNTING AS STANDARD

The wall mount exit luminaire Esc 1 has a metal and plastic frame. Illumination is provided by a fluorescent lamp as a light source. Because of its design, Esc 1 can be installed in places where a long line of sight is required but the installation space for the luminaire is limited.
DIMENSIONS
221 204 204 67 136 162 5

81

74

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TW30521 TW30581 TW30581K GTIN code 6438045002224 6438045000053 6438045002699 viewing distance < 40 m < 40 m < 40 m Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC Input power 7 VA / 7W 8 VA / 5,5 W 7,5 VA / 5W Light source 5W 2G7 5W 2G7 5W 2G7 Operation mode CBU CBU CBU / C Temperature range -10+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 1,0 1,0 1,0

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TW30582 GTIN code 6438045000060 viewing distance < 40 m Supply voltage 230 V AC Input power 15 VA Light source 5W 2G7 Operation mode 1 h battery Temperature range maintained -5+30C non-maintained 0 +35C Electrical installation 4/3 x 2,5 mm2 -oWeight (kg) 1,2

SEPARATELY ORDERED PICTOGRAMS


Product code PB071B PB062B PB061B PB102 GTIN code 6438045001845 6438045001838 6438045001821 6438045001340 Pictogram Product description Down arrow Right arrow Left arrow Multifunction

| Pictograms in the table are 1-sided

ACCESSORIES
Product code TW30520 TW30530 GTIN code 6438045001180 6438045000169 Product Flag and ceiling bracket for two luminaires Ceiling bracket for one luminaire

FLAG AND CEILING BRACKET TW30520


100

CEILING BRACKET TW3530


200

50

50

190

240

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

75

EXIT AND EMERGENCY LUMINAIRES

ESC 1,5

EN 60598-2-22

EN 1838

-o-

IP 20

40 M vIEWING DISTANCE

WALL MOUNTING AS STANDARD

CAN BE USED AS AN EXIT OR AN EMERGENCY LUMINAIRE

The Esc 1,5 exit luminaire has a metal and plastic frame suitable for wall mounting. Illumination is provided by a fluorescent lamp as a light source. Because of its long viewing distance, up to 40 meters, the luminaire is well suited for large areas.

DIMENSIONS

423

316

204

67 204

162

76

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TW41722 TW41781 TW41781K GTIN code 6438045000084 6438045001135 6438045002705 viewing distance < 40 m < 40 m < 40 m Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC Input power 9 VA / 11 W 12 VA / 9W 11 VA / 8W Light source 9W 2G7 9W 2G7 9W 2G7 Operation mode CBU CBU CBU / C Temperature range -10+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 1,2 1,2 1,2

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TW41782 GTIN code 6438045001142 viewing distance < 40 m Supply voltage 230 V AC Input power 18 VA Light source 9W 2G7 Operation mode 1 h battery Temperature range maintained -5+30C non-maintained 0 +35C maintained -5+30C non-maintained 0 +35C Electrical installation 3 x 2,5 mm2 -oWeight (kg) 1,4

TW41783

6438045002132

< 40 m

230 V AC

19 VA

9W 2G7

3 h battery

3 x 2,5 mm2 -o-

1,4

SEPARATELY ORDERED PICTOGRAMS


Product code PB171B PB168B PB158B PB103 GTIN code 6438045001876 6438045001869 6438045001852 6438045001357 Pictogram Product description Down arrow Right arrow Left arrow Multifunction

| Pictograms in the table are 1-sided

ACCESSORIES
Product code TW30520 TW41730 GTIN code 6438045001180 6438045001227 Product Flag and ceiling bracket for two luminaires Ceiling bracket for one luminaire
50

CEILING BRACKET TW30520


100

CEILING BRACKET TW41730

420

50
190

240

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TW41722, TW41781, TW41781K

TW41722, TW41781, TW41781K

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 9 10

R4 (m) 1 lux 3,5 4

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 7 7

R3 (m) 0,5 lux 7 7

R4 (m) 0,5 lux 4 4

2,5 4

10,9 4,3

3,5 4

2,5 4

10,9 4,3

4 4

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

77

EXIT AND EMERGENCY LUMINAIRES

ESC 3

EN 60598-2-22

EN 1838

-o-

IP 20

IP 44

70 - 120 M vIEWING DISTANCE

WALL AND SUSPENSION MOUNTING AS STANDARD

HOOKS INCLUDED IN THE PACKAGE

The elegant exit luminaire Esc 3 has an extruded aluminium frame and has been designed for long viewing distances. The luminaire is suitable for wall, ceiling and suspended mounting. The luminaire can be used in a single or double face configuration. Illumination is provided by a fluorescent lamp as a light source. Having a viewing distance of up to 120 m, the Esc 3 is well-suited for large public areas. TWT397 has a protection rating of IP44 and TWT494 IP20.

TWT397xx
647
29 647 30 21 194

121
39 21 509 413

391

5 500

391

72

391

121 6

TWT494xx
1259 96 5 634 634 128 1000 29 1259 30 21 634 39 121 6 121 21 1117 1025

78

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code GTIN code viewing distance Supply voltage Input power Light source Operation mode Temperature range Electrical installation Weight (kg)

The following luminaires have a protection rating of IP44: TW39722 TW39723 TW39781 TW39781K TW39782 TW39782K 6438045004761 6438045004693 6438045004778 6438045004709 6438045004785 6438045004716 < 70 m < 70 m < 70 m < 70 m < 70 m < 70 m 24 V AC/DC 24 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 26 VA / 18 W 26 VA / 18 W 22 VA / 18 W 23 VA / 19 W 22 VA / 18 W 23 VA / 19 W 18 W G13 18 W G13 18 W G13 18 W G13 18 W G13 18 W G13 CBU CBU CBU CBU / C CBU CBU / C -10+50C -10+50C -10+50C -10+50C -10+50C -10+50C 2 x 2,5 mm2 -o2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o4,6 4,6 4,6 4,6 4,6 4,6

The following luminaires have a protection rating of IP20: TW49422 TW49423 TW49481 TW49481K TW49482 TW49482K 6438045004723 6438045004730 6438045005157 6438045004747 6438045005027 6438045004754 < 120 m < 120 m < 120 m < 120 m < 120 m < 120 m 24 V AC/DC 24 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 41 VA / 37 W 41 VA / 37 W 38 VA / 32 W 39 VA / 33 W 38 VA / 32 W 39 VA / 33 W 36 W G13 36 W G13 36 W G13 36 W G13 36 W G13 36 W G13 CBU CBU CBU CBU / C CBU CBU / C -10+50C -10+50C -10+50C -10+50C -10+50C -10+50C 2 x 2,5 mm2 -o2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o9,8 9,8 9,8 9,8 9,8 9,8

| The following luminaires can be used as 2-sided: TW39723, TW39782, TW39782K, TW49423, TW49482 and TW49482K. The rest ones can be only as 1-sided.

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SEPARATELY ORDERED PICTOGRAMS


Product code PB3973 PB3972 PB3971 PB4943 PB4942 PB4941 GTIN code 6438045004921 6438045004914 6438045004907 6438045005119 6438045005102 6438045005096 viewing distance < 70 m < 70 m < 70 m < 120 m < 120 m < 120 m Pictogram Product description Down arrow Right arrow Left arrow Down arrow Right arrow Left arrow For luminaire TW397xx TW397xx TW397xx TW494xx TW494xx TW494xx

| Pictograms in the table are 1-sided

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

79

EXIT AND EMERGENCY LUMINAIRES

ESC SECTOR

EN 60598-2-22

EN 1838

-o-

IP 20

26 M vIEWING DISTANCE

WALL MOUNTING AS STANDARD

The Esc Sector has a plastic and metal frame. Its design makes it possible to see the exit symbol from various viewing angles. The luminaire is designed for wall mounting. The product line consists of models having either a long-life LED or a fluorescent lamp as a light source. The Esc Sector is well suited for locations where the escape route signs must be visible from various viewing angles.

DIMENSIONS
288 137 147 288 147 80 288 240

4,5

137

147

80

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TW88821 TW88881 TW88881K TW88871W TW88851WK GTIN code 6438045000510 6438045000527 6438045002729 6438045006024 6438045006031 viewing distance < 26 m < 26 m < 26 m < 26 m < 26 m Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC 24-230 V AC/DC 230 V AC/DC Input power 7 VA / 7 W 8 VA / 5,5 W 7,5 VA / 5 W 24 V= 7,5 VA / 4 W 230 V= 11 VA / 4 W 10 VA / 5,5 W Light source 5W 2G7 5W 2G7 5W 2G7 LED LED Operation mode CBU CBU CBU / C CBU CBU / C Temperature range -10+50C -10+50C -10+50C -30+50C -30+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,7 0,7 0,7 0,7 0,7

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TW88882 TW88852W TW88883 GTIN code 6438045000534 6438045006048 6438045001616 viewing distance < 26 m < 26 m < 26 m Supply voltage 230 V AC 230 V AC 230 V AC Input power 15 VA 9 VA 16 VA Light source 5W 2G7 LED 5W 2G7 Operation mode 1 h battery 1 h battery 3 h battery Temperature range -5+30C -5+30C -5+30C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,9 0,9 0,9

SEPARATELY ORDERED PICTOGRAMS


Product code PB8881 PB8882 PB8883 GTIN code 6438045001883 6438045001890 6438045001906 Pictogram Product description Left arrow Right arrow Down arrow

| Pictograms in the table are 1-sided

ACCESSORIES
Product code XW88801 GTIN code 6438045003061 Product Ceiling bracket for one luminaire
49

CEILING BRACKET XW88801

49

195

195

280

195

280

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

81

EXIT AND EMERGENCY LUMINAIRES

LEDmAN

EN 60598-2-22

EN 1838

-o-

IP 20

20 M vIEWING DISTANCE

WALL MOUNTING AS STANDARD

The compact Ledman has a plastic frame and is suited for wall mounting. Long-lasting LEDs are used as a light source. Ledman is designed for locations where the installation space for the luminaire is very limited.

DIMENSIONS
114 3,5 59 114 97 114 114 63 69 26

59 21 97 30

114

59

37

114

82

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TW47441 TW47481 GTIN code 6438045001517 6438045001524 viewing distance < 20 m < 20 m Supply voltage 24 V AC/DC 230 V AC/DC Input power 1 VA / 1,5 W 2 VA / 2,5 W Light source LED LED Operation mode CBU CBU Temperature range -30+50C -30+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,3 0,3

| Multifunction pictogram is included in the luminaires in the table.

CBU = Centrally supplied

ACCESSORIES
Product code XW47402 TW47403 TW47404 6438045000114 6438045000121 GTIN code Product Front cover with multifunction pictogram Ceiling bracket for one luminaire V-shaped bracket for ceiling and wall mounting

CEILING BRACKET TW47403


44 44 129 84

BRACKET FOR CEILING AND WALL MOUNTING TW47404


164

129

115 164 115

84

72

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

83

EXIT AND EMERGENCY LUMINAIRES

ESC CUBE

EN 60598-2-22

EN 1838

-o-

IP 20

65 M vIEWING DISTANCE

CEILING MOUNTING AS STANDARD

Esc Cube is cube-shaped exit luminaire providing four sides on which the exit symbol can be attached. The frame is made of plastic and metal. The luminaire is appropriate for ceiling or suspended mounting. Illumination is provided by a fluorescent lamp. The Esc Cube is suitable for large public areas, such as shopping centres, where the escape route is through a staircase in the centre area. In such cases, a single Esc Cube luminaire can provide escape route guidance to the whole area.

DIMENSIONS

362

362 260 21

26

371

371

270 26

84

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWK6321 TWK6381 TWK6381K GTIN code 6438045004792 6438045004808 6438045004686 viewing distance < 65 m < 65 m < 65 m Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC Input power 26 VA / 18 W 22 VA / 18 W 23 VA / 18 W Light source 18 W 2G11 18 W 2G11 18 W 2G11 Operation mode CBU CBU CBU / C Temperature range -10+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 3,7 3,7 3,7

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SEPARATELY ORDERED PICTOGRAMS


Product code PB6304 GTIN code 6438045004945 Pictogram Product description Right arrow

PB6305

6438045004938

Left arrow

PB6306

6438045004952

Down arrow

PB6307

6438045004969

Left arrow

PB6308

6438045004976

Right arrow

PB6309

6438045004983

Down arrow

PB63011

6438045006512

Multifunction

| Pictograms in the table are 1-sided

ACCESSORIES
Product code TW77504B GTIN code 6438045006093 Product Suspension bracket for one luminaire

SUSPENSION BRACKET TW77504B


85 5,5 Max. 1000mm 43

115

417

57

43

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

85

EXIT AND EMERGENCY LUMINAIRES

SAFE 6

EN 60598-2-22

EN 1838

-o-

IP 44

CEILING, WALL AND FLAG MOUNTING AS STANDARD

The elegant emergency luminaire Safe 6 has a plastic frame and can be ceiling, wall or side mounted, or suspended. The product line consists of models having a long-life LEDs as a light source. As the luminaires in the Safe 6 product line are protected against splashing water, they are also suited for installations in wet areas and in parking garages, outdoor shelters, etc.

CEILING MOUNTING

WALL MOUNTING
79

FLAG MOUNTING
281

17 58

14

84 267

96

96

18

21

18

23

124

63 84

86

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT06051WK TWT06071W GTIN code 6438045010458 6438045010465 Supply voltage 230 V AC/DC 24-230 V AC/DC Input power 12,5 VA / 7,5 VA 24 V=9 VA / 8 W 230 V=15 VA / 6,5 W Light source LED LED Operation mode CBU/C CBU Temperature range -30 +50C -30 +50C Electrical installation 3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -oWeight (kg) 1,0 1,0

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TWT0652WA TWT0652WM GTIN code 6438045009674 6438045009681 Supply voltage 230 V AC 230 V AC Input power 2,9 VA 2,9 VA Light source LED LED Operation mode 1 h battery + Aalto 1 h battery +M Temperature range -10 +30C -10 +30C Electrical installation 3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -oWeight (kg) 1,0 1,0

Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

ACCESSORIES
Product code TW77504B TWT6001 XWT0655 GTIN code 6438045006093 6438045006550 6438045010489 Product Suspension bracket Recess mounting frame Lens set

RECESS INSTALLATION FRAME TWT6001 302 72 279 5


109 81 268 58

SUSPENSION BRACKET TW77504B


5,5 85 115 43 Max. 1000mm

66

106 43

57

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWT0652WM (luminaire with lens)

TWT0652WM (luminaire without separate lens)

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 9,5 11 13

R4 (m) 1 lux 1 1 1

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 5 6

R3 (m) 0,5 lux 5 6

R4 (m) 0,5 lux 3 3,5

2,5 4 6

21 8 3,6

3,5 4,5 5,5

2,5 4

5,8 2,2

3 3,5

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

87

EXIT AND EMERGENCY LUMINAIRES

LINESPOT

EN 60598-2-22

EN 1838

-o-

IP 20

RECESS MOUNTING ONLY

APERTURE FOR MOUNTING 75 MM

Linespot, a recess mount emergency luminaire utilising the latest LED technology, is designed especially for illuminating corridors. The luminaire optics are designed to produce a long and narrow field of light which effectively illuminates emergency escape routes and enables maximum spacing between the luminaires. Linespots small size and stylish design make energy-efficient emergency lighting possible without detracting from the general appearance of the area.

DIMENSIONS

101

46

55

101

TWT5071W

TWT5053Wx

OTHER TYPES

45 54

229 215

21 55

45

290 277 4,5 290

21

229 215 55 4,5 229 43 34

46

290 277

21

4,5 229

34

4,5 290

35

101

43 75

101 75

101 75

48

88

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT5071W TWT5051WK GTIN code 6438045007212 6438045007229 Supply voltage 24-230 V AC/DC 230 V AC/DC Input power 24 V=7,5 VA / 4 W 230 V=11 VA / 4 W 10 VA / 5,5 W Light source LED LED Operation mode CBU CBU / C Temperature range -30+50C -30+50C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,35 0,35

SELF-CONTAINED LUMINAIRES
Product code TWT5052W TWT5052WM TWT5053WM TWT5052WA GTIN code 6438045007236 6438045008196 6438045008219 6438045008189 Supply voltage 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC Input power 9 VA 9 VA 9 VA 9 VA Light source LED LED LED LED

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units Operation mode 1 h battery 1 h battery +M 3 h battery +M 1h battery+ Aalto 3 h battery + Aalto 1 h Escap 1 h Escap + Aalto 1 h Escap +M Temperature range 0+35C 0+35C 0+35C 0+35C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,4 0,4 0,4 0,4

TWT5053WA TWS5092W TWS5092WA TWS5092WM

6438045008202 6438045008158 6438045008165 6438045008172

9 VA 5 VA 5 VA 5 VA

LED LED LED LED

0+35C -25+35C -25+35C -25+35C

0,4 0,4 0,4 0,4

Escap = Self-contained luminaire with 1 h capacitor backup Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

R4 Y R1 R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

TWT5051WK, TWT5071W

TWS5092W, TWS5092WM, TWS5092WA

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 8 12 16 17

R4 (m) 1 lux 1 1 1 1

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 7 7

R4 (m) 1 lux 1 1

2,5 4 6 8

38 14 6 3

3,5 5,5 6 6,5

2,5 4

7 2,8

2,5 2,5

TWT5052W, TWT5052WM, TWT5052WA

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 8 11 14

R4 (m) 1 lux 1 1 1

2,5 4 6

14 5 2,5

3,5 5,5 6

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

89

EXIT AND EMERGENCY LUMINAIRES

ZONESPOT

EN 60598-2-22

EN 1838

-o-

IP 20

RECESS MOUNTING ONLY

APERTURE FOR MOUNTING 75 MM

Zonespot, a recess mount emergency luminaire utilising the latest LED technology, has been designed especially for illuminating open areas. The luminaires optics are designed to produce a wide and even field of light to effectively illuminate broad open areas without creating disturbing contrasts. Zonespots small size and stylish design make energy-efficient emergency lighting possible without detracting from the general appearance of the area.

DIMENSIONS

101

45 53

101

TWT6471W
229 215 75 67 34

TWT6453Wx

OTHER TYPES
290 277 21 34 4,5 290 101 75 48 43 35

45 53

229 215

229 215 21 4,5 4,5

45 53

4,5 229

101 75

75 67 43 101

229

229

90

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT6471W TWT6451WK GTIN code 6438045008035 6438045008028 Supply voltage 24-230 V AC/DC 230 V AC/DC Input power 24 V=7,5 VA / 4 W 230 V=11 VA / 4 W 10 VA / 5,5 W Light source LED LED Operation mode CBU CBU / C Temperature range -30+50C -30+50C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,35 0,35

SELF-CONTAINED LUMINAIRES
Product code TWT6452W TWT6452WM TWT6453WM TWT6452WA TWT6453WA TWS6492W TWS6492WA TWS6492WM GTIN code 6438045008042 6438045008066 6438045008080 6438045008059 6438045008073 6438045008226 6438045008233 6438045008240 Supply voltage 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC Input power 9 VA 9 VA 9 VA 9 VA 9 VA 5 VA 5 VA 5 VA Light source LED LED LED LED LED LED LED LED

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units Operation mode 1 h battery 1 h battery + M 3 h battery + M 1 h battery + Aalto 3 h battery + Aalto 1 h Escap 1 h Escap + Aalto 1 h Escap + M Temperature range 0+35C 0+35C 0+35C 0+35C 0+35C -25+35C -25+35C -25+35C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4

Escap = Self-contained luminaire with 1 h capacitor backup Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWT6451WK, TWT6471W

TWT6451WK, TWT6471W

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 6,4 8,2 8,2

R4 (m) 1 lux 2,8 3 4,2

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 5 5,4 6

R3 (m) 0,5 lux 5 5,4 6

R4 (m) 0,5 lux 3,7 3,3 2

2,5 4 6

8,5 3,3 1,5

2,8 3 4,2

2,5 4 6

8,5 3,3 1,5

3,7 3,3 2

TWT6452W,TWT6452WA,TWT6452WM

TWT6452W,TWT6452WA,TWT6452WM

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 5,8 5,8

R4 (m) 1 lux 2 1,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 4 4

R3 (m) 0,5 lux 4 4

R4 (m) 0,5 lux 2,5 2,5

2,5 4

4 1,5

2 1,5

2,5 4

4 1,5

2,5 2,5

TWS6492W, TWS6492WA, TWS6492WM

TWS6492W, TWS6492WA, TWS6492WM

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 5

R4 (m) 1 lux 1,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 3,4

R3 (m) 0,5 lux 3,4

R4 (m) 0,5 lux 2,3

2,5

2,4

1,5

2,5

2,4

2,3

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

91

EXIT AND EMERGENCY LUMINAIRES

SLImSPOT

EN 60598-2-22

EN 1838

-o-

IP 20

RECESS MOUNTING ONLY

APERTURE FOR MOUNTING 75 MM

Slimspot is a recess mount invisible emergency luminaire which blends into the ceiling structure almost imperceptibly. This luminaire utilises the latest LED technology providing optics which do not produce an irritatingly bright LED light spot. Slimspots small size and streamlined design make energy-efficient emergency lighting possible without detracting from the interior design elements.

DIMENSIONS
40 42

TWT9771W
229 215 42 21 4,5 229 34

TWT9751WK
290 277 21 290 43 103 48 75

40

103

4,5

35

103 75

70

40 42 2 103

92

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT9771W TWT9751WK GTIN code 6438045009001 6438045009018 Supply voltage 24-230 V AC/DC 230 V AC/DC Input power 24 V= 7,5 VA / 4 W 230 V=11 VA / 4 W 10 VA / 5,5 W Light source LED LED Operation mode CBU CBU / C Temperature range -30+50C -30+50C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,35 0,35

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWT9751WK, TWT9771W

TWT9751WK, TWT9771W

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 5,4 6,4

R4 (m) 1 lux 2,2 2,2

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 4 5

R3 (m) 0,5 lux 4 5

R4 (m) 0,5 lux 3,3 3

2,5 4

5,9 2,3

2,2 2,2

2,5 4

5,9 2,3

3,3 3

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

93

EXIT AND EMERGENCY LUMINAIRES

LINESPOT

EN 60598-2-22

EN 1838

-o-

IP 20

SURFACE MOUNTING ONLY

Linespot, an emergency luminaire utilising the latest LED technology, is designed especially for illuminating corridors. The luminaire optics are designed to produce a long and narrow field of light which effectively illuminates emergency escape routes and enables maximum spacing between the luminaires. Linespots small size and stylish design make energy-efficient emergency lighting possible without detracting from the general appearance of the area.

DIMENSIONS

180

21 25
180 184

180 49 5,2 20 78 25 53 21

139 90 76

97

94

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT7871W TWT7851WK GTIN code 6438045009100 6438045009117 Supply voltage 24-230 V AC/DC 230 V AC/DC Input power 24 V= 7,5 VA /4 W 230 V= 11 VA /4 W 10 VA / 5,5 W Light source LED LED Operation mode CBU CBU / C Temperature range -30+50C -30+50C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,67 0,67

SELF-CONTAINED LUMINAIRES
Product code TWT7852W TWT7852WM TWT7853WM TWT7852WA TWT7853WA TWS7892W TWS7892WA TWS7892WM GTIN code 6438045009124 6438045009148 6438045009162 6438045009131 6438045009155 6438045009179 6438045009186 6438045009193 Supply voltage 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC Input power 9 VA 9 VA 9 VA 9 VA 9 VA 5 VA 5 VA 5 VA Light source LED LED LED LED LED LED LED LED

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units Operation mode 1 h battery 1 h battery +M 3 h battery +M 1 h battery + Aalto 3 h battery + Aalto 1 h Escap 1 h Escap + Aalto 1 h Escap +M Temperature range 0+35C 0+35C 0+35C 0+35C 0+35C -25+35C -25+35C -25+35C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8

Escap = Self-contained luminaire with 1 h capacitor backup Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

R4 Y R1 R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

TWT7871W, TWT7851WK

TWS7892W, TWS7892WM, TWS7892WA

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 8 12 16 17

R4 (m) 1 lux 1 1 1 1

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 7 7

R4 (m) 1 lux 1 1

2,5 4 6 8

38 14 6 3

3,5 5,5 6 6,5

2,5 4

7 2,8

2,5 2,5

TWT7852W, TWT7852WM, TWT7852WA

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 8 11 14

R4 (m) 1 lux 1 1 1

2,5 4 6

14 5 2,5

3,5 5,5 6

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

95

EXIT AND EMERGENCY LUMINAIRES

ZONESPOT

-o-

IP 20

SURFACE MOUNTING

Zonespot, an emergency luminaire utilising the latest LED technology, has been designed especially for illuminating open areas. The luminaires optics are designed to produce a wide and even field of light to effectively illuminate open areas without creating disturbing contrasts. Zonespots small size and stylish design make energy-efficient emergency lighting possible without detracting from the general appearance of the area.

DIMENSIONS

180 21 25 180 184 139 90 76 97 5,2 49 20 180 53 25 21

78

96

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT9471W TWT9451WK GTIN code 6438045009209 6438045009216 Supply voltage 24-230 V AC/DC 230 V AC/DC Input power 24 V=7,5 VA / 4 W 230 V=11 VA / 4 W 10 VA / 5,5 W Light source LED LED Operation mode CBU CBU / C Temperature range -30+50C -30+50C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,65 0,65

SELF-CONTAINED LUMINAIRES
Product code TWT9452W TWT9452WM TWT9453WM TWT9452WA TWT9453WA TWS9492W TWS9492WA TWS9492WM GTIN code 6438045009223 6438045009247 6438045009261 6438045009230 6438045009254 6438045009278 6438045009285 6438045009292 Supply voltage 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC Input power 9 VA 9 VA 9 VA 9 VA 9 VA 5 VA 5 VA 5 VA Light source LED LED LED LED LED LED LED LED

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units Operation mode 1 h battery 1 h battery + M 3 h battery + M 1 h battery + Aalto 3 h battery + Aalto 1 h Escap 1 h Escap + Aalto 1 h Escap + M Temperature range 0+35C 0+35C 0+35C 0+35C 0+35C -25+35C -25+35C -25+35C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8

Escap = Self-contained luminaire with 1 h capacitor backup Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWT9471W, TWT9451WK

TWT9471W, TWT9451WK

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 6,4 8,2 8,2

R4 (m) 1 lux 2,8 3 4,2

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 5 5,4 6

R3 (m) 0,5 lux 5 5,4 6

R4 (m) 0,5 lux 3,7 3,3 2

2,5 4 6

8,5 3,3 1,5

2,8 3 4,2

2,5 4 6

8,5 3,3 1,5

3,7 3,3 2

TWT9452W, TWT9452WA, TWT9452WM

TWT9452W, TWT9452WA, TWT9452WM

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 5,8 5,8

R4 (m) 1 lux 2 1,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 4 4

R3 (m) 0,5 lux 4 4

R4 (m) 0,5 lux 2,5 2,5

2,5 4

4 1,5

2 1,5

2,5 4

4 1,5

2,5 2,5

TWS9492W, TWS9492WA, TWS9492WM

TWS9492W, TWS9492WA, TWS9492WM

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 5

R4 (m) 1 lux 1,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 3,4

R3 (m) 0,5 lux 3,4

R4 (m) 0,5 lux 2,3

2,5

2,4

1,5

2,5

2,4

2,3

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

97

EXIT AND EMERGENCY LUMINAIRES

mINI LINESPOT
RECESS MOUNTING

-o-

IP 20

APERTURE FOR SPOT 30 MM

Mini Linespot, an emergency luminaire utilising the latest LED technology, is designed especially for illuminating corridors. The luminaire optics are designed to produce a long and narrow field of light which effectively illuminates emergency escape routes and enables maximum spacing between the luminaires. Linespots small size and stylish design make energy-efficient emergency lighting possible without detracting from the general appearance of the area. The luminaire is also provided with brackets for suspended installation which enables integration of a Mini Linespot with general lighting fixtures.
29

DIMENSIONS
30

32

38

52

38
20

TWT7371W
229 43 229 215 21

TWT7353Wx
290 48 290 277 21 4,5 21 229 215 4,5 229 43

OTHER TYPES
290

48 32 52 290 277 21 4,5

32 52

32 52

4,5

34

| NOTE! Electronic part does not fit through the aperture

98

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT7371W TWT7351WK GTIN code 6438045009308 6438045009315 Supply voltage 24-230 V AC/DC 230 V AC/DC Input power 24 V= 7,5 VA / 4 W 230 V= 11 VA / 4 W 10 VA / 5,5 W Light source LED LED Operation mode CBU CBU / C Temperature range -30+50C -30+50C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,38 0,38

CBU = Centrally supplied C = Compatible with the Tapsa Control central battery unit

SELF-CONTAINED LUMINAIRES
Product code TWT7352W TWS7392W GTIN code 6438045009322 6438045009377 Supply voltage 230 V AC 230 V AC Input power 9 VA 5 VA Light source LED LED Operation mode 1 h battery 1 h Escap Temperature range 0+35C -25+35C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,4 0,4

Escap = Self-contained luminaire with 1 h capacitor backup

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

R4 Y R1 R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

TWT7371W, TWT7351WK

TWS7392W

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 8 12 16 17

R4 (m) 1 lux 1 1 1 1

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 7 7

R4 (m) 1 lux 1 1

2,5 4 6 8

38 14 6 3

3,5 5,5 6 6,5

2,5 4

7 2,8

2,5 2,5

TWT7352W

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 8 11 14

R4 (m) 1 lux 1 1 1

2,5 4 6

14 5 2,5

3,5 5,5 6

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

99

EXIT AND EMERGENCY LUMINAIRES

TWINSPOT

-o-

IP 20

SEMI-RECESSED MOUNTING ON A jUNCTION BOX / SURFACE MOUNTING

Twinspot, an emergency luminaire utilising the latest LED technology, can be surface mounted or installed over a junction box. The luminaire contains two separate LED light sources with optics designed to produce an exceptionally long field of light. Twinspot is especially well-suited for areas where maximum spacing between the luminaires is desired.
DIMENSIONS
73 76

44

137
137

76 55

44

137

4 55

100

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT3571W TWT3551WK GTIN code 6438045006987 6438045006994 Supply voltage 24-230 V AC/DC 230 V AC/DC Input power 24 V=9 VA / 8 W 230 V=15 VA / 6,5 W 12 VA / 7,5 W Light source LED LED Operation mode CBU CBU / C Temperature range -30+50C -30+50C Electrical installation 3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -oWeight (kg) 0,35 0,35

| Luminaires in the table are double insulated

CBU = Centrally supplied C = Compatible with the Tapsa Control central battery unit

SELF-CONTAINED LUMINAIRES
Product code TWT3552W TWT3553W GTIN code 6438045007007 6438045007601 Supply voltage 230 V AC 230 V AC Input power 18 VA 19,5 VA Light source LED LED Operation mode 1 h battery 3 h battery Temperature range 0+35C 0+35C Electrical installation 3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -oWeight (kg) 0,4 0,4

| Luminaires in the table are double insulated


TWT3501
5,5 85 43 115

ACCESSORIES
Product code TWT3501 GTIN code 6438045008400 Product Suspension bracket

Max. 1000mm

57 128

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWT3571W, TWT3551WK

TWT3571W, TWT3551WK

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 11,5 16

R4 (m) 1 lux 1 1

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 8 12

R3 (m) 0,5 lux 1,5 1,5

R4 (m) 0,5 lux 2 2

2,5 4

7,5 3

5 7

2,5 4

7,5 3

4,5 6,5

TWT3552W, TWT3553W

TWT3552W, TWT3553W

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 11 12

R4 (m) 1 lux 1 1

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 8 8,5

R3 (m) 0,5 lux 1,5 1,5

R4 (m) 0,5 lux 2 2

2,5 4

6 2,5

5 6

2,5 4

7,5 3

4,5 5,4

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

101

EXIT AND EMERGENCY LUMINAIRES

SAFESPOT

-o-

IP 20

IP 44

SURFACE MOUNTING

Safespot, a surface mount emergency luminaire, utilises the latest LED technology. This luminaire combines small outside dimensions with easy installation and a stylish design. Safespot suits locations where recess mounting is not possible, yet it provides an almost unnoticeable solution. The luminaire has a standard protection rating of IP20 and with special gaskets a rating of IP44.

DIMENSIONS
264 220

264

45 139 139 45 12

17 264 114

5,5

102

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT4471W TWT4451WK GTIN code 6438045007243 6438045007250 Supply voltage 24-230 V AC/DC 230 V AC/DC Input power 24 V=7,5 VA / 4 W 230 V=11 VA / 4 W 10 VA / 5,5 W Light source LED LED Operation mode CBU CBU / C Temperature range -30+50C -30+50C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,35 0,35

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TWT4452W TWT4452WM TWT4453WM TWT4452WA TWT4453WA TWS4492W TWS4492WA TWS4492WM GTIN code 6438045007595 6438045008257 6438045008264 6438045007472 6438045007489 6438045006758 6438045007403 6438045007410 Supply voltage 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC Input power 9 VA 9 VA 9 VA 9 VA 9 VA 5 VA 5 VA 5 VA Light source LED LED LED LED LED LED LED LED Operation mode 1 h battery 1 h battery + M 3 h battery + M 1 h battery + Aalto 3 h battery + Aalto 1 h Escap 1 h Escap + Aalto 1 h Escap + M Temperature range 0+35C 0+35C 0+35C 0+35C 0+35C -25+35C -25+35C -25+35C Electrical installation 3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,4 0,6 0,6 0,6 0,6 0,6 0,6 0,6

Escap = Self-contained luminaire with 1 h capacitor backup Aalto = Aalto Control compatible (incl. Lumi Test) M = Self-contained luminaire with Lumi Test self-testing

ACCESSORIES
Product code TWT4401 Product Gasket set for IP44 version

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

103

EXIT AND EMERGENCY LUMINAIRES

SAFESPOT
LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

-o-

IP 20

IP 44

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWT4471W, TWT4451WK

TWT4471W, TWT4451WK

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 3 6 8

R4 (m) 1 lux 1,5 2,5 3,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 2,5 4 5

R3 (m) 0,5 lux 2,5 4 5

R4 (m) 0,5 lux 1,7 2,5 3

2,5 4 6

20 8 3,6

1,5 2,5 3,5

2,5 4 6

20 8 3,6

1,7 2,5 3

TWT4452W, TWT4452WM, TWT4452WA, TWT4453WM, TWT4453WA

TWT4452W, TWT4452WM, TWT4452WA, TWT4453WM, TWT4453WA

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 3 5 7

R4 (m) 1 lux 1,5 2,5 3

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 2 3 5

R3 (m) 0,5 lux 2 3 5

R4 (m) 0,5 lux 1,5 2 3

2,5 4 6

14 5,5 2,4

1,5 2,5 3

2,5 4 6

14 5,5 2,4

1,5 2 3

TWS4492W, TWS4492WA, TWS4492WM

TWS4492W, TWS4492WA, TWS4492WM

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 2 3

R4 (m) 1 lux 1 1,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 2 2

R3 (m) 0,5 lux 2 2

R4 (m) 0,5 lux 1,5 1,5

2,5 4

9,6 3,7

1 1,5

2,5 4

9,6 3,7

1,5 1,5

104

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

Dubai Metro, Dubai, U.A.E.

references

Tallinn airport, Tallinn, Estonia

Shopping Centre Nevsky, St. Petersburg, Russia

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

105

EXIT AND EMERGENCY LUMINAIRES

SAFE 22
SURFACE MOUNTING

-o-

IP 44

SURFACE AND RECESS MOUNTING

RECESS MOUNTING

The Safe 22, a surface and recess mount emergency luminaire, is appropriate for illuminating fairly large areas. Due to its protection rating, it is also wellsuited for damp or dusty areas.

DIMENSIONS

196

21 20

256 31

21 119

270 25

59 105 46

5 34 39 27

270

106

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT2221 TWT2224 TWT2281 TWT2281K TWT2284 TWT2284K GTIN code 6438045005614 6438045005621 6438045005638 6438045005645 6438045005669 6438045005676 Supply voltage 24 V AC/DC 24 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC 230 V AC/DC Input power 9 VA / 11 W 26 VA / 18 W 12 VA / 9W 11 VA / 8W 22 VA / 18 W 22 VA / 18 W Light source 9W 2G7 18 W 2G11 9W 2G7 9W 2G7 18 W 2G11 18 W 2G11 Operation mode CBU CBU CBU CBU / C CBU CBU / C Temperature range -10+50C -10+50C -10+50C -10+50C -10+50C -10+50C Electrical installation 3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -o3/2 x 2,5 mm2 -oWeight (kg) 1,0 1,0 1,0 1,0 1,0 1,0

| Luminaires in the table are double insulated

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TWT2282 GTIN code 6438045005652 Supply voltage 230 V AC Input power 18 VA Light source 9W 2G7 Operation mode 1 h battery Temperature range maintained -5+30C non-maintained 0 +35C maintained -5+30C non-maintained 0 +35C Electrical installation 3/2 x 2,5 mm2 -oWeight (kg) 1,1

TWT2283

6438045009742

230 V AC

19 VA

9W 2G7

3 h battery

3/2 x 2,5 mm2 -o-

1,1

| Luminaires in the table are double insulated

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

107

EXIT AND EMERGENCY LUMINAIRES

SAFE 22
LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

-o-

IP 44

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWT2221, TWT2281, TWT2281K

TWT2221, TWT2281, TWT2281K

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 8 10 11

R4 (m) 1 lux 3,5 3,5 3,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 7 8 8

R3 (m) 0,5 lux 7 8 8

R4 (m) 0,5 lux 3,5 4,5 4,5

2,5 4 6

14 5 2,5

3,5 3,5 3,5

2,5 4 6

14 5 2,5

3,5 4,5 4,5

TWT2224, TWT2284, TWT2284K

TWT2224, TWT2284, TWT2284K

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 11 14 15 16

R4 (m) 1 lux 4,5 5,5 5,5 5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 8 10 11 11

R3 (m) 0,5 lux 8 10 11 11

R4 (m) 0,5 lux 4,5 5,5 6 6

2,5 4 6 8

34 13 6 3,4

4,5 5,5 5,5 5

2,5 4 6 8

34 13 6 3,4

4,5 5,5 6 6

TWT2282

TWT2282

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 5

R4 (m) 1 lux 1,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 4

R3 (m) 0,5 lux 4

R4 (m) 0,5 lux 2,5

2,5

2,5

1,5

2,5

2,5

2,5

TWT2283

TWT2283

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 5

R4 (m) 1 lux 1,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 4

R3 (m) 0,5 lux 4

R4 (m) 0,5 lux 2,5

2,5

1,5

2,5

2,5

108

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

references

Malm Arena, Malm, Sweden

King Abdullah Financial District parcels (El Seif 3.04, 3.05, 3,45), Riyadh, Saudi Arabia

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

109

EXIT AND EMERGENCY LUMINAIRES

ON-IN
SURFACE MOUNTING

-o-

IP 44

SURFACE AND RECESS MOUNTING

RECESS MOUNTING

The TW422, a surface or recess mount emergency luminaire is appropriate for illuminating fairly large areas. Due to its protection rating, it is also wellsuited for damp or dusty areas.

DIMENSIONS RECESS MOUNTING


240 73 37 240 73

DIMENSIONS SURFACE MOUNTING


240 73 37 240 73

40

240 200 140 78

240

43

110

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TW42222C TW42281C TW42281CK GTIN code 6438045000626 6438045000633 6438045002842 Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC Input power 9 VA / 11 W 12 VA / 9W 11 VA / 8W Light source 9W 2G7 9W 2G7 9W 2G7 Operation mode CBU CBU CBU / C Temperature range -10+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,7 0,7 0,7

| Luminaires in the table are suitable for recess mounting

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

CENTRALLY SUPPLIED LUMINAIRES


Product code TW42222G TW42281G TW42281GK GTIN code 6438045000718 6438045000756 6438045002880 Supply voltage 24 V AC/CD 230 V AC/DC 230 V AC/DC Input power 9 VA / 11 W 12 VA / 9W 11 VA / 8W Light source 9W 2G7 9W 2G7 9W 2G7 Operation mode CBU CBU CBU / C Temperature range -10+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,7 0,7 0,7

| Luminaires in the table are suitable for surface mounting

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TW4222C, TW42281C, TW42281CK, TW42222G, TW42281G, TW42281GK

TW4222C, TW42281C, TW42281CK, TW42222G, TW42281G, TW42281GK

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 10 12

R4 (m) 1 lux 4 4,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 7 8

R3 (m) 0,5 lux 7 8

R4 (m) 0,5 lux 4 4,5

2,5 4

14 5,5

4 4,5

2,5 4

14 5,5

4 4,5

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

111

EXIT AND EMERGENCY LUMINAIRES

DOWNLIGHT
RECESS MOUNTING ONLY

-o-

IP 20

APERTURE FOR RECESS MOUNTING 185 MM

The TW956, a recess mountable emergency luminaire. has a bright reflector and diffuser to make it stylish and provide excellent luminance. It is especially suited for areas where the general lighting is also supplied by downlight luminaires of a similar type.

DIMENSIONS

196

185

362 161 189 51 91

189 169

21

78

82 91 196

9 326 362

15

46

58 21

112

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TW95622 TW95681 TW95681K GTIN code 6438045001623 6438045001630 6438045002811 Supply voltage 24 V AC/CD 230 V AC/DC 230 V AC/DC Input power 9 VA / 11 W 12 VA / 9W 11 VA / 8W Light source 9W 2G7 9W 2G7 9W 2G7 Operation mode CBU CBU CBU / C Temperature range -10+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,7 0,7 0,7

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

SELF-CONTAINED LUMINAIRES
Product code TW95682 GTIN code 6438045001647 Supply voltage 230 V AC Input power 18 VA Light source 9W 2G7 Operation mode 1 h battery Temperature range maintained -5+30C non-maintained 0 +35C maintained -5+30C non-maintained 0 +35C Electrical installation 3 x 2,5 mm2 -oWeight (kg) 1,0

TW95683

6438045001654

230 V AC

19 VA

9W 2G7

3 h battery

3 x 2,5 mm2 -o-

1,0

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TW95622, TW95681, TW95681K

TW95622, TW95681, TW95681K

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 7 10 12

R4 (m) 1 lux 3,5 4 5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 6 7 9

R3 (m) 0,5 lux 6 7 9

R4 (m) 0,5 lux 3,5 4 4,5

2,5 4 6
TW95682

20 8 3

3,5 4 5

2,5 4 6
TW95682

20 8 3

3,5 4 4,5

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 4

R4 (m) 1 lux 1,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 3

R3 (m) 0,5 lux 3

R4 (m) 0,5 lux 2

2,5

2,2

1,5

2,5

2,2

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

113

EXIT AND EMERGENCY LUMINAIRES

TWT58

-o-

IP 20

RECESS MOUNTING ONLY

The TWT58 is a recess mountable emergency luminaire. The prismatic diffuser of these models provides excellent light efficiency, and the units can be mounted on walls as well as on ceilings.

DIMENSIONS

351 80

61

35

21

4,5

75

75

88

100 30

88 270 391

114

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWT5821 TWT5881 TWT5881K GTIN code 6438045010427 6438045010434 6438045010441 Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC Input power 10 VA / 9W 12 VA / 8,5 W 10,5 VA / 8W Light source 8W G5 8W G5 8W G5 Operation mode CBU CBU CBU / C Temperature range -10+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,8 0,8 0,8

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWT5821, TWT5881, TWT5881K

TWT5821, TWT5881, TWT5881K

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 8 10 12 13

R4 (m) 1 lux 3,5 4,5 4,5 4

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 5 7 7 8

R3 (m) 0,5 lux 5 7 7 8

R4 (m) 0,5 lux 3 4 4 4,5

2,5 4 6 8

17 6,7 3 1,7

3,5 4,5 4,5 4

2,5 4 6 8

17 6,7 3 1,7

3 4 4 4,5

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

115

EXIT AND EMERGENCY LUMINAIRES

TWK 41 /42
RECESS MOUNTING, TWK41

-o-

IP 20

RECESS AND SURFACE MOUNTING

SURFACE MOUNTING, TWK42

The TWK41 is a recess mount and the TWK42, a surface mount emergency luminaire. The luminaires design enables stylish and coordinated lighting solutions which blend into the surroundings. The TWK41 and TWK42 are well-suited as emergency luminaires located in dry areas.

DIMENSIONS OF TWK41 RECESS MOUNTING


351 70 3 82 380 89 111

DIMENSIONS OF TWK42 SURFACE MOUNTING

351

351 4,5 4,5 5 82 116 22 52 288 351 81 41 89 70 3 111 24 156 25 29 21

386 21

71

30

271 321 80

21

116

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CENTRALLY SUPPLIED LUMINAIRES


Product code TWK4121 TWK4181 TWK4181K GTIN code 6438045004860 6438045004877 6438045009759 Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC Input power 10 VA / 9W 12 VA / 8,5 W 10,5 VA / 8W Light source 8W G5 8W G5 8W G5 Operation mode CBU CBU CBU / C Temperature range -10+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 1,5 1,5 1,5

| Luminaires in the table are suitable for recess mounting

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

CENTRALLY SUPPLIED LUMINAIRES


Product code TWK4221 TWK4281 TWK4281K GTIN code 6438045009766 6438045009773 6438045009780 Supply voltage 24 V AC/DC 230 V AC/DC 230 V AC/DC Input power 10 VA / 9W 12 VA / 8,5 W 10,5 VA / 8W Light source 8W G5 8W G5 8W G5 Operation mode CBU CBU CBU / C Temperature range -10+50C -10+50C -10+50C Electrical installation 2 x 2,5 mm2 -o3 x 2,5 mm2 -o3 x 2,5 mm2 -oWeight (kg) 0,7 0,7 0,7

| Luminaires in the table are suitable for surface mounting

CBU = Centrally supplied C = Compatible with Tapsa Control central battery units

LIGHT DISTRIBUTION TABLES Emergency lighting for escape routes (ceiling mounting)
| Table of 1 lux for escape routes in the middle line according to the norm EN 1838. | Level of measurement 0,02 m, measurement result with battery operation

Emergency lighting for open areas (ceiling mounting)


| Table of 0,5 lux for open areas according to the norm EN 1838, 0,5 m edge district is considered in the table. | Level of measurement 0,02 m, measurement result with battery operation.

R4 Y R1 R2 X
Y

R4 R3 R1

R2 X

| R1 distance from wall (X axis ) | R2 installation distance between luminaires (X axis)

| R4 distance from wall (Y axis)

| R1 distance from wall (X axis) | R3 installation distance between luminaires (Y axis) | R2 installation distance between luminaires (X axis) | R4 distance from wall (Y axis)

TWK4121, TWK4181, TWK4181K

TWK4121, TWK4181, TWK4181K

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 8 9

R4 (m) 1 lux 3,3 3,5

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 6 7

R3 (m) 0,5 lux 6 7

R4 (m) 0,5 lux 3,5 4

2,5 4

9,9 3,8

3,3 3,5

2,5 4

9,9 3,8

3,5 4

TWK4221, TWK4281, TWK4281K

TWK4221, TWK4281, TWK4281K

Mounting height (m)

Below the luminaire lux

R1 (m) 1 lux

R2 (m) 1 lux 7 8

R4 (m) 1 lux 4 4

Mounting height (m)

Below the luminaire lux

R1 (m) 0,5 lux

R2 (m) 0,5 lux 7 7

R3 (m) 0,5 lux 7 7

R4 (m) 0,5 lux 4 4

2,5 4

5 2,2

3 3

2,5 4

5 2,2

4 4

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

117

SHOCK PROTECTING COVERS

SHOCK PROTECTING COVERS


| Shock protecting covers are used in e.g. sports halls, gymnasiums and stadiums.

Product code

For luminaire

Dimensions (mm) X Y 120 Z 305 A 240

TW77508B

TWT35xx, TW416xx, TWT17xx, TWS17xx, TW399xx, TWT82xx TW8906x, TW8908x, TWT46xx, TWT47xx, TW888xx, TW305xx, TWT60xx, TW850xx, TW844xx, TWT22xx, TW422xx TW417xx, TW333xx, TW802xx, TW891xx, TWT48xx, TWT62xx, TWT29xx, TWS29xx, TWS62xx

220

TW77507B

320

165

305

340

TW77510B

420

165

505

440

Flora Park Hotel, Dubai, U.A.E.

references

118

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

FREQUENTLY ASKED QUESTIONS


GENERAL Question: What do the following signs mean? Answer:

-o-

= Luminaire is suitable for through-wiring = Double insulated luminaire (doesnt need an earthing cable)

IP 20

= Protection rating = The product conforms with the essential requirements of the applicable EC directives.

Question: Why emergency lighting is needed? Answer: Emergency lighting is mandatory in workplaces and public buildings. Emergency lighting makes possible the safe ending of working and evacuation of the building in case of an emergency. Question: Is there a minimum order quantity? Answer: No, you can order just one luminaire, but there is a fee for small delivery. Extra handling fee is 100 for a shipment of an order under 250.

Question: How fast can I get products? Answer: Typical delivery time for the products in the catalogue is two to three (2-3) weeks (Ex-works) from the written order, but faster delivery is also often possible depending on the product, capacity of our production, and the amount of the products you want to order. Delivery date will be confirmed with the order confirmation.

ABOUT LUMINAIRES Question: Can I have luminaires in other colours than in white or grey (which are basic colours for Teknoware luminaires)? Answer: Yes, almost all the luminaires can be painted in RAL colours (there will be extra charge of painting).

Question: Do I need to to buy a pictogram for exit luminaire? Answer: Pictogram needs to be bought always separately for exit luminaires. Direction of the arrow needs to be informed in the order, pictogram can be a label or light plate depending on the luminaire. There are so called multifunction labels for some exit luminaires. You can choose the figure by yourself and remove the parts of the label with e.g. a knife. With light plates you have to know the direction of arrow, because there is no multifunction figure available. Question: Is the pictogram fixed into the luminaire ? Answer: Pictogram will be fixed into the luminaire in our production unless customer asks pictogram to be packed sepately. Separately packed pictograms customer has to paste / fix by oneself. Sometimes label needs to be cut for the shape. Taping labels into the luminaire cover is included in the price of the luminaire, when pictogram is bought together with the exit luminaire.

ABOUT CENTRAL BATTERY UNITS Question: What kind of central battery unit do I need? Answer: It depends on the size of the central battery unit you will need, if you need an addressable or a non-addressable system, how many circuits there should be, how many and what kind of emergency and exit luminaires will be used in the system and should it work in 24 V or 230 V system. Question: How do I calculate what kind of batteries I need for the Central battery unit? Answer: You have to calculate the total input power of all the (exit and emergency) luminaires is the system (total load / central battery unit).

Question: Do I need a battery cabinet or battery cables? Answer: It depends on the central battery unit and size of the batteries. If you need a separate battery cabinet you will also need a battery cable. Some central battery units have space for batteries, and there is no need for a separate battery cabinet. For example, there is space for 2 x 38 Ah batteries in TK2301-04 central battery units, bigger than 38 Ah batteries need a separate battery cabinet. Question: What kind of battery cabinet do I need? Answer: It depends on the batteries. You will find the tables of battery cabinets on every central battery unit page at the beginning of this product catalogue.

Question: Which one of the battery cables is correct for my system? Answer: Battery cable will be determined based on the batteries. You will find the tables of battery cables on every central battery unit page at the beginning of this product catalogue.

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

119

TERMS & CONDITIONS

TERmS & CONDITIONS


| If not otherwise agreed, we quote the following terms and conditions. Terms of delivery Terms of payment Delivery time Luminaires EXW, Lahti, Finland, Incoterms 2010 According to agreement The delivery time is confirmed for each order with the order confirmation. Typically it is two-three weeks (Ex-works) from written order. Pictogram needs to be ordered always separately. Pictogram will be pasted into the exit luminaire cover at the factory without extra fee. If pictogram is wanted to be separately packed, it needs to be clearly informed in the order. Emergency luminaire includes EMERGENCY LUMINAIRE label in the package. Delay interest 8%. Interest of delayed payments will be determined according to Directive 2000/35/EC of the European Parliament and of the Council of 29 June 2000. Teknoware Oy retains full ownership of the goods until the invoices have totally been paid. Prior hereto, buyers cannot transfer ownership to anyone. Other terms Other terms according to orgalime supply conditions, August 2000; no other compensations can be demanded.

We reserve the rights to make modifications without notice.

Teknoware team at your service!

120

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

CONTACT INFORmATION
| Teknoware Oy, Ilmarisentie 8, FI-15200 Lahti, Tel: +358 (0)3 883 020 , Fax: +358 (0)3 8830 260, Email: emexit@teknoware.eu, www.teknoware.eu

Teknoware headquarters and production facilities, Lahti, Finland

Emergency lighting unit Business Unit Director Mr Jari Tabell Export Manager Mr Simo Kurki Product Manager Mr Pasi Hongisto Export Secretary Ms Jenni Hannikainen

Telephone +358 (0)3 883 0264 +358 (0)3 883 178 +358 (03) 883 0233 +358 (03) 883 0292

Email emexit@teknoware.eu jari.tabell@teknoware.eu simo.kurki@teknoware.eu pasi.hongisto@teknoware.eu jenni.hannikainen@teknoware.eu

After Sales after sales service, technical assistance, reclamations After Sales Manager Mr Markus Laurell

Telephone +358 (03) 883 0186

Email aftersales@teknoware.eu

Teknoware Emergency Lighting Product Catalogue 2012 - Edition 2

121

Teknoware Oy, Ilmarisentie 8 FI-15200 LAHTI, FINLAND Tel. +358 3 883 020 Fax +358 3 883 0260 www.teknoware.eu emexit@teknoware.eu

T359 / 04 / 12