IEC 898: 10000 A, IEC 947-2: 15 kA

circuit protection
circuit-breakers up to 63 A

functions

The circuit-breakers combine the following


functions:
- protection of circuits against short-circuit
currents,
- protection of circuits against overload
currents,
- control,

- isolation,
- protection of persons against indirect
contact with TN and IT neutral systems.
C60H circuit-breakers are used in the
tertiary and industrial sectors

description

technical data common to C60H circuitbreakers


# power circuit
5 voltage rating: 440 V AC
5 breaking capacity
- according to IEC 898, Icn ultimate breaking
capacity (O-CO cycle):

B curve

rating

type

voltage

(A)

(V)

0.563 1P
2P, 3P, 4P

breaking
capacity
Icn (A)

230400 10 000
400415 10 000

Ics = 75 % of Icn
- according to IEC 947-2, Icu ultimate
breaking capacity (O-CO cycle):
rating

type

voltage

(A)

(V)

breaking
capacity
Icu (kA)

0.563 1P

130
30
240
15
415
4 (1)
2P, 3P, 4P
240
30
415
15
440
10
(1) breaking capacity under 1 pole with IT isolated
neutral system (case of double fault).

5 limitation class (EN 60898): 3


5 fast closing: allows the high inrush

utilisation
when the short-circuit currents are weak
(generators, long cables).
technical data
# power circuit
5 ratings: 6 to 63 A set at 30 C
5 tripping curve:
the magnetic trip units operate between 3
and 5 In.

C curve
utilisation
cables feeding conventional loads.
technical data
# power circuit
5 ratings: 0.5 to 63 A set at 30 C
5 tripping curve:
the magnetic trip units operate between 5
and 10 In.

D curve
utilisation
loads with high inrush currents (motors,
transformers).
technical data
# power circuit
5 ratings: 0.5 to 63 A set at 30 C
5 tripping curve: the magnetic trip units
operate between 10 and 14 In.

currents of some loads to be better held


5 isolation with positive break indication:
opening is indicated by a green strip on the
device operating handle. This indicator
shows opening of all the poles
5 number of cycles (O-C): 20 000
# environment
5 tropicalisation: treatment 2 (relative
humidity: 95 % at 55 C)
5 weight (g):
type

1P
120

2P
240

3P
360

4P
480

5 connection: tunnel terminals for the


following cables:
- 16 mm2 flexible or 25 mm2 rigid up to 25 A
ratings
- 25 mm2 flexible or 35 mm2 rigid for 32 to
63 A ratings.

catalogue numbers

type

rating
(A)

catalogue
number

width
quantity
in mod. per batch
of 9 mm

6
10
16
20
25
32
40
50
63

24643
24644
24646
24647
24648
24649
24650
24651
24652

2
2
2
2
2
2
2
2
2

B curve C60H
1P
1

12
12
12
12
12
12
12
12
12

24643

90095E.fm/2

Updated: 4/07/01

Schneider Electric

C60H circuit-breakers
B, C and D curves
IEC 898: 10000 A, IEC 947-2: 15 kA

circuit protection
circuit-breakers up to 63 A

catalogue numbers

type

rating
(A)

catalogue
number

width
quantity
in mod. per batch
of 9 mm

B curve C60H (continued)


2P
1

6
10
16
20
25
32
40
50
63

24725
24726
24727
24728
24729
24730
24731
24732
24733

4
4
4
4
4
4
4
4
4

6
6
6
6
6
6
6
6
6

6
10
16
20
25
32
40
50
63

24738
24739
24740
24741
24742
24743
24744
24745
24746

6
6
6
6
6
6
6
6
6

4
4
4
4
4
4
4
4
4

6
10
16
20
25
32
40
50
63

24751
24752
24753
24754
24755
24756
24757
24758
24759

8
8
8
8
8
8
8
8
8

3
3
3
3
3
3
3
3
3

0.5
0.75
1
2
3
4
6
10
16
20
25
32
40
50
63

24900
24901
24968
24969
24970
24971
24972
24973
24974
24975
24976
24977
24978
24979
24980

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

0.5
0.75
1
2
3
4
6
10
16
20
25
32
40
50
63

24902
24903
24981
24982
24983
24984
24985
24986
24987
24988
24989
24990
24991
24992
24993

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

24729
3P

24742
4P

24756

C curve C60H
1P
1

24972

2P

24988

Schneider Electric

Updated: 4/07/01

90095E.fm/3

C60H circuit-breakers
B, C and D curves
IEC 898: 10000 A, IEC 947-2: 15 kA

circuit protection
circuit-breakers up to 63 A

catalogue numbers

type

rating
(A)

catalogue
number

width
quantity
in mod. per batch
of 9 mm

C curve C60H (continued)


3P
1

25002

4P

25016

0.5
0.75
1
2
3
4
6
10
16
20
25
32
40
50
63

24906
24907
24994
24995
24996
24997
24998
24999
25000
25001
25002
25003
25004
25005
25006

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

0.5
0.75
1
2
3
4
6
10
16
20
25
32
40
50
63

24908
24909
25007
25008
25009
25010
25011
25012
25013
25014
25015
25016
25017
25018
25019

8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

0.5
1
2
3
4
6
10
16
20
25
32
40
50
63

25171
25152
25155
25157
25158
25159
25160
25161
25164
25165
25166
25167
25168
25169

2
2
2
2
2
2
2
2
2
2
2
2
2
2

12
12
12
12
12
12
12
12
12
12
12
12
12
12

0.5
1
2
3
4
6
10
16
20
25
32
40
50
63

25172
25183
25184
25185
25186
25187
25188
25189
25190
25191
25192
25193
25194
25195

4
4
4
4
4
4
4
4
4
4
4
4
4
4

6
6
6
6
6
6
6
6
6
6
6
6
6
6

D curve C60H
1P
1

25159

2P

25191

90095E.fm/4

Updated: 4/07/01

Schneider Electric

C60H circuit-breakers
B, C and D curves
IEC 898: 10000 A, IEC 947-2: 15 kA

circuit protection
circuit-breakers up to 63 A

catalogue numbers

type

rating
(A)

catalogue
number

width
quantity
in mod. per batch
of 9 mm

D curve C60H (continued)


3P
1

25205

4P

25219

additional
information
Schneider Electric

0.5
1
2
3
4
6
10
16
20
25
32
40
50
63

25173
25196
25197
25198
25199
25200
25201
25202
25203
25205
25207
25208
25209
25210

6
6
6
6
6
6
6
6
6
6
6
6
6
6

4
4
4
4
4
4
4
4
4
4
4
4
4
4

0.5
1
2
3
4
6
10
16
20
25
32
40
50
63

25174
25211
25212
25213
25214
25215
25216
25217
25218
25219
25220
25221
25222
25223

8
8
8
8
8
8
8
8
8
8
8
8
8
8

3
3
3
3
3
3
3
3
3
3
3
3
3
3

Vigi modules: page 90115/2


electrical auxiliaries : page 90142/2
accessories: page 91903/2
dimensions: page 90148/2

curves: page 90180/2

Updated: 4/07/01

90095E.fm/5

You might also like