You are on page 1of 6

COMPOSITE SLAB ANALYSIS/DESIGN

DESIGN&CONSTRUCTION/IMPROVEMENTOFMISAMISOCCIDENTAL PROVINCIALCAPITOLBUILDING&DESIGN&CONSTRUCTIONOF GRANDSTANDWITHCLASSROOMS&COMMERCIALSPACE


MISAMISOCCIDENTAL


SALVADORF.FUTOLDatePrepared:Oct.06,2012 StructuralEngineer Reg.No.25545 PTRNo.6044908 Placeofissue:QuezonCity DateofIssue:January05,2012
No.3E.M.CuerpoInc.Building,metropolisDrive,MetropoliResidenza,BagumbayanQuezonCity,Tel:(02)6355663

DESIGNCRITERIA DESIGNLOADS A. DeadLoad FloorLoad, ConcreteMaterial 23.60kN/m3 SteelMaterial76.82kN/m3 B. LiveLoad MultipurposeArea DESIGNSTRESSES A. ConcreteCompressiveStrength,fc B. RebarYieldStrength,fy C. SteelYieldStrength,fy STANDARD&CODES A. B. C. D. E. F. NationalStructuralCodeofthePhilippines,NSCP2001/NSCP2010 UniformBuildingCode1997,UBC1997 AmericanSocietyofCivilEngineers,ASCE0705 AmericanConcreteInstitute,ACI31805 AmericanInstituteofSteelConstruction,AISC2005 AmericanSteelDeckInstitute,SDI 4.8kPa

20.7MPa

276MPa

248MPa

PARAMETERS t Ip Sx(t) Sx(b) As Fc Fy Fy c d yo Vn = = = = = = = = = = = = 0.8 mm 217322 mm 8985 mm 8166 mm 459.28 20.7 248 276 2.36 0.06 20.71 6.6
4 3 4 2

, thickness , moment of inertia in positive bending , section modulus in positive moment , section modulus in negative moment ,steel deck area per unit width ,concrete compressive strength ,deck yield strength & hot-rolled ,rebar yield strength , concrete density ,deck density , cg of deck alone , factor deck shear strength

mm MPa MPa MPa kPa kPa mm kN

ANALYSIS USING LRFD

dd hc h Wr b Cs d

= = = = = = =

50 50 100 136.6 574.1 250 79.29

mm mm mm mm mm mm mm

Calculate the composite section properties and moment, the clear span is 3 meter assume no negative bending moment for conservative design, so the composite slab will be a simple span. design span Moment of inertia of the cracked section

As = bd
=

0.01009 Es/Ec = 9.19

Ycc d 2n (n)2 n hc
Ycc = 27.58 mm < 50

therefore, OKAY Ycs = d-Ycc = 51.71 mm

Ic
Isf Sc

b 3 2 Ycc AsYcs Isf 3n


= = Ip Ic/h-Ycc

1882253 mm

25989.18 mm

Moment of inertia of the uncracked section


0.5bh2 nA sd Wrdd (h 0.5dd ) c bhc nA s Wr dd b Cs b Cs

Ycc

2228622 48610.2 48610 2 33.44 mm

45.85 mm

Ycs

d-Ycc

Iu

4 4545257 mm

Moment of inertia of the composite section Id = Iu + Ic 2 =


4 3213755 mm

DL = DL = LL = LL = LL = w=

1.2 (wconc + wdeck) 1.67 1 67 kN/m 1.6 (multi purpose LL) 1.6 (4.8 *0.574) 4.41 kN/m DL+LL 6.08 kN/m

Allowable moment Mn= Mn= Mn= FySc


3 -5 0.85 (276x10 )(2.5989x10 ) 5.48 kN.m

Positive moment at L = 3 Mn = Mn = therefore, wL/12 4.56

m (simply supported) kN.m

<

Mn SATISFACTORY

therefore, bottom bar is not necessary Top reinforcement calculation Negative moment at L = 3 m Mn = Mn = wL/10 5.47 (continous) kN.m

considering 1 meter strip, d= 100-20-10/2 = Mu = Rubd Ru = 1.08 (1sqrt(12Ru/0.85fc)) p= 0.85fc fy p= 0.004 pmin = 0.005 pmax = 0.027 pused = 0.005 As = pbd mm As = 380.43 using 10mm bar mm Ab = 78.54 n= As/Ab n= 4.84 S= 206.61 mm say S = 115 mm Temperature bar (considering 1 meter strip) mm Ab = 78.54 As = 0.0015bh As = 150 mm n= 1.91 S= 1000/n = 523 mm say S = 300 mm

75 mm

therefore,