You are on page 1of 2

ANNA UNIVERSITY: CHENNAI 600 025 B.E/B.

.Tech Degree Practical Examinations Oct / Nov 2012 EE2208-MEASUREMENTS AND INSTRUMENTATION LABORATORY B.E. ELECTRICAL AND ELECTRONICS ENGINEERING Regulations - 2008 Time: 3 Hours 1 Maximum Marks: 100 100

By conducting suitable experiment measure the linear displacement using the transducer which works in inductive transduction principle and draw its characteristics curve. Conduct experiment to measure the pressure using two transducer stages and draw input output characteristics of the transducer used. Perform suitable experiment to find the unknown self inductance of the given inductors using the bridge in which obtaining balance is easy for low Q coils. Also measure Q-factor of the given inductors. Find out the value of capacitance and its dissipation factor of the given capacitors using an experiment with suitable ac bridge. Perform an experiment to measure the resistance value of the given resistors using a DC Bridge which is suitable for measurement of medium resistance. Also find the sensitivity of the used bridge. Perform measurement of resistance of the given resistors accurately using a DC bridge which has double set of ratio arms. With suitable experiment obtain the characteristics of operational amplifier as instrumentation amplifier. Obtain the digital output of analog input using 4 bit SAR ADC by suitable experiment and verify the practical output with theoretical output. With suitable measurement obtain the digital output of analog input using 4 bit Ramp type ADC and verify the practical output with theoretical output. With suitable measurement obtain the analog outputs of the digital inputs using R-2R ladder network and verify the practical output with theoretical output.

2 3

100 100

4 5

100 100

6 7 8 9 10

100 100 100 100 100

11

Find the analog equivalent of the digital inputs by designing a 4 bit Weighted resistor 100 type D/A converter and verify the result with theoretical output. 100

12 13

A circuit consists of a resistance and inductance in series. Observe and draw the response of the circuit during transient time with suitable experiment. A meter which works with induction principle to measure the energy consumption of a 100 single phase electrical load. Conduct suitable test on that meter to calibrate and calculate the percentage error. By suitable experiment measure the single phase energy consumption of the load 100 which operates at unity power factor and check the practical results with theoretical results. Find out the error in the given instrumentation transformer used for measuring high 100 current by conducting suitable test. Perform test on given single phase current transformer and draw the curve between the 100 primary and secondary currents and calculates its efficiency. Measure the consumption of power and power factor of a three phase balanced load 100 and obtain the angle between the voltage and current by conducting suitable experiment. Perform test to find the permeability, flux density, sum of hysterisis and eddy current 100 loss of the given magnetic material using bridge method. An energy meter has to be tested using single phase supply without any electrical load. 100 Conduct suitable experiment and find the error in meter. Use two watt meters to measure real and reactive power consumption of star 100 connected resistive inductive load by suitable test .Also measure the operating power factor of the circuit.

14

15

16

17

18

19

20

You might also like