You are on page 1of 2

Checks Performed The following parameters in design calculations have been checked and tabulated:S.

No Definition Design Criteria 1 Loading Detail 1.1) Live Load Live Load-Residential/Office area Checked from relevant Code for each floorLobby and Public Area Parking area and ramps Storage area Swimming pool area,Healthclub Balcony and stairs Transformer/Generator room Electricity room and telephone room Technical and Mechanical room Retail areas Office areas Residential areas 1.2) Dead Load Superimposed Dead Load-Residential Superimposed Dead Load-Office Area 1.3) Lateral Loads 1.3.1) Wind LoadBasic Wind Speed, Vb Altitude factor Sa factor, Direction factor, Sd Seasonal Factor, Ss Probabilty Factor, Sp Terrain and Building Factor, Sb Effective Wind Speed Ve 1.3.2) Seismic Load Type of Analysis-Static/Dynamic Seismic Zone Z-Factor Soil Profile Type Importance Factor Seismic Coefficient , Ca Seismic Coefficient , Cv Type of Structural framing system Determination of ductility factor, R 2 Load Combinations 3 Material Properties Appropriate factored load combinations considered Check characteristic Cube compressive strength after 28 days forFoundations Slabs and Beams Walls and columns Characteristic Strength Fy of steel reinforcement Appropriate concrete cover to steel reinforcement Checked

ETAB Model check 1 Geometry Length/width of entire building-matching with architectural drawings Slab thickness taken at each basement, podium level as well as typical floors and roof Size of column at each level Beam sizes at each level Check entered characteristic Cube compressive strength after 28 days forFoundations Slabs and Beams at all levels Walls and columns at all levels Characteristic Strength Fy of steel reinforcement Appropriate concrete cover to steel reinforcement Check the values of stiffness modifiers given for each element. Check support conditions given for all columns at the base Check for any extra supports assigned at all other levels Check live load assigned at each floor and area Check superimposed dead load assigned at each floor and area Check wind loads and parameters assigned for wind loads Check seismic loads and parameters assigned for seismic loads Check if Appropriate factored load combinations considered Check stability analysis parameters Check drift of the building Check Deflections Check Time Period Check Amplitude and Vibrations if valid

2 Materials

3 Base Constraints

4 Load Input in model

5 Load Combinations 6 Analysis

Design Check-Through 7 ETABS,Manually,MIDAS,SAFE,ot For horizontal framing elementsher softwares Slabs on each level Beams at each level For vertical framing elementsColumns at all the levels Walls at each level -Shear,Core , Block Raft foundation Staircase Other-Tank,Retaining walls 8 Drawing Check Check compatibility of all architectural with structural drawings Check drawing numbering Check Reinforcement details of all structural elements Check General notes and legibility/no overlap

You might also like