CRYO-DERM

IONTOPHORESIS + MSG REJUVENATION + Electroporation

CRYO-DERM

INDEX
1. Name and Components 2. Direction to Use 3. Features of Cryo_Derm 4. Principle and Effects of Cryoelectrophoresis 5. Cryo_Derm Program 6. Cryo_Derm Treatment 7. Specification 8. Warranty Information

CRYO-DERM 1. Name and Components

CRYO & THERMO ELECTROPORATION ELECTRO MESO MEDICINE & SOLUTION INJECTION <Accessories>

PART NAME
Cryo & Thermo Electrode Hand piece

IMAGE

PART NAME
Earth Rod

IMAGE

Cryo & Thermo Electrode for Body

Injection Electrode Hand piece

Earth Rod

Foot Switch for Injection

CRYO-DERM 1. Name and Components

CH.1 Cryo/thermo Control 1CH: Cryo/Thermo Electrode Control

Common Control

CH.2 Injection Electrode Control

<MODE> button: Choose Cryo or Thermo Electrode Function Choose one among 5 modes like Ion soft, Ion hard, Ion lift, Ion MSG, Rejuvenation

<OFF/MAX> button: Output Intensity of Cryo/Thermo Amount of Output for Cryo/Thermo and Ion, Ion Lift, Rejuvenation stimulation

<PLUS/MINUS> Polarity button: Choose one between (+) and (-) Choose one when use of Ion soft, Ion hard, Ion lift functions

<TEMP UP/DOWN>: Settle up temp. using UP/DOWN COLD -10 ~ +10 HOT +35 ~ +45

2CH: Injection Electrode Control <MODE>button: Choose Injection Electrode function Choose one among 5 modes like Ion soft, Ion hard, Ion lift, Ion MSG, Rejuvenation <OFF/MAX> button: Output Intensity of Injection Electrode Amount of Output for Generating Cryo/Thermo and Ion, Ion Lift, Rejuvenation stimulation.: <PLUS/MINUS> Polarity button: Choose one between (+) and (-)

Choose one when use of Ion soft, Ion hard, Ion lift functions <FLOW SPEED> control button for volumes of flow control the volumes of injection flow of ampoule 4

CRYO-DERM 1. Name and Components Common Control <TIME> button: Control time to use. / Setting time: 20min. <START/STOP> button Start/stop the output for Ion, Ion Lift, Rejuvenation stimulation

Objects of Use - Ampoule Application - Sedation of sensitive skin, Pore minimization, Increase of blood circulation - Ion penetration, Skin lift, Skin rejuvenation

This device, Cryo_Derm, is possible to apply to two people at the same time. HOWEVER, it is impossible to apply ION soft & hard at the same time. That is When selection of ION HARD, ION SOFT on 1CH cryo/thermo electrode Mode, It is not able to use two functions of 2CH. At this time, ION LIFT, ION MSG, REJUVENATION is only able to be used on 2CH injection mode.

Stand by Screen

Processing Screen

CRYO-DERM 2. Direction to Use Direction to use for CH. 1 : Cryo/Thermo Elcetrode

CH.1 Cryo/thermo Control

Common Control

CH.2 Injection Electrode Control

1. Usage of CH.1 Cryo/Thermo Elcetrode Start treatment after checking it whether client grip Ground Rod <Mode>- Choose one among 5 functions <PLUS/MINUS> - Choose one between (+) and (-) It is relevant to 3 Functions like Ion soft, Ion hard, Ion lift. <Temperature>- Settle up temp. using UP/DOWN button COLD HOT -10 ~ +10 +35 ~ +45

<Time>- Control time to use / Setting time: 20min <START> Start the operation after settle up desired Mode, Temp., Time and check the ground earth rod

<Intensity> Control Output rate and Intensity. Slowly turn the intensity up during the operation Range of Intensity: Control between 0% & 100%

<STOP> Pause button. The STOP button works pause function during operation. In case only Cryo/Thermo is used without electric stimulation Choose desired Temp. Do not use Ground Rod because of no electric stimulation 6

CRYO-DERM 2. Direction to Use Direction to use for CH.2 Injection Electrode

CH.1 Cryo/thermo Control

Common Control

CH.2 Injection Electrode Control

2. Usage of CH.2 Injection Electrode Start treatment after checking it whether client grip Ground Rod <Mode>- Choose one among 5 functions <PLUS/MINUS> - Choose one between (+) and (-) It is relevant to 3 Functions like Ion soft, Ion hard, Ion lift. <FLOW SPEED>- Control the volume of injection flow depending on formulation of ampoules Low Medium High Weak Medium Strong

<Time>- Control time by using time button /Setting time: 20min. <START> Start the operation after settle up desired Mode, Temp., Time and check the ground earth rod <Intensity> Control Output rate and Intensity. Slowly turn the intensity up during the operation Range of Intensity: Control between 0% and 100% <FOOT SWITCH> Adjust ampoule injections flux stepping FOOT SWITCH. The ampoule only flows while stepping in the switch. It will be started with PeeP sound. <STOP> Pause button. The STOP button works pause function during operation. 7

CRYO-DERM 2. Direction to Use

Zero Start Error: If all volumes are not on Zero level after you start the device, you can see the below error massage and warning sound. So in order to make the device go on, all volume levels are on Zero and then automatically it goes on processing.

After using an injection electrode, the nozzle could be clogged or have a hygienic problem because of viscosity of ampoule. How to work CLEAR Mode: : Proceed the mode when continue to push FLOW SPEED button for 3 sec.

How to control the nozzle : On the low setting and stepping in the food switch, adjust the flow volume by turning the particle controller. You can adjust the flow setting depending ampoule density.

CRYO-DERM 2. Direction to Use

How to deal with CRYO_DERM after Use.


1) Clean up the main body with dry cloth. Possible to occurs variation of the device when using chemicals 2) Clean up the used cryo/thermo electrode with wet cloth first and then use dry cloth Possible to occurs variation of the device when using chemicals 3) Remove remaining ampoule on the used injection electrode by tapping it on other hand covered dry cloth Clean up the electrode head with wet cloth first and then use dry cloth. The remaining ampoule keep clogged in the electrodes until next usage If you dont use it for more than one day, use the Clean Mode to clean up inside with cleaning solution taking off ampoule bottle and then store it. Possible to occurs variation of the device when using chemicals and may have a problem with injection pump unless use clear solution. 4) Cleaned injection is stored at its stand. . If the injection is put up-down side, the ampoule would be leaked. 5) Change the water in water tank after using 6 ~ 9 months later. If period of change cooling water is long, there is problem with cryo/thermo system by cause of waste material inside.

CRYO-DERM 3. Features of Cryo_Derm 1) Cryo and Thermo Cryo_Derm works by thermoelectric semiconductor to make cool and hot. Surface of semiconductor is cooling when absorbing the heat and heating when exhausting the heating. So it works in water based exhaust system for the best effectiveness. Cooling effect helps skin calm and pores minimize and there is double effect of penetrating ion when use ion function together. Thermo effect helps blood circulation improve and pores enlarge.

2) Ampoule Injection It is different that Cryo_Derm has automatic built-in ampoule injection than other equipment which has a problem that a nozzle is clogged often. The ampoule injection is able to adjust its flux according to viscosity and kind of ampoule by user friendly, FOOT SWITCH. 3) Iontophoresis Cryo_Derms iontophoresis works by 3.8 KHz medium frequency which penetrates into deep layer of skin. It is based on the electrical repulsive power to bring more effective penetration of vitamins, mineral and collagen than cosmetics or ampoules. 4) Ion-Lifting Using 250Hz, it would make face-lifting effect by stretching in and out with soft ion feeling and current penetration principle. 5) Lifting Massage It is focused on skin lifting effect using both poles of 200Hz medium and low frequency. 6) REJUVENATION It brings rejuvenation and vitalization effect on skin using bioelectricity which exhales from body when human does exercise.

10

CRYO-DERM 3. Features of Cryo_Derm Cryo_Derm is a professional skin care device for those who need professional skin care. It makes active ampoule applied to skin by using an injection electrode and brings effects such as skin soothing, contraction and enlargement of pores, improvement of blood circulation, ion application and ion lifting using a injection electrode.

Save treatment time by applying ampoule using injection electrode and iontophoresis simultaneously.

Maximize iontophoresiss function using cyro/thermo electrode and improve skin condition such as skin soothing, contraction and enlargement of pores, improvement of blood circulation.

Possible to do treatment two people at the same time.

Easy to master in comparison with various functions.

Be suitable output for individual skin by adjusting fine output

Possible to control the volume of injection flow according to viscosity and kind of ampoule.

Possible to use anywhere without special equipment for power supply due to a freeVolt adaptor built-in.

Be tailored treatment for individual skin due to various modes.

11

CRYO-DERM 4. Principle & Effects of Cryoelectrophoresis

Principle of Cryoelectrophoresis

Principle of Cryoelectrophoresis Cryoelectophoresis makes pores sizes enlarged to help to penetrate active ingredients into skin and then when adding electric stimulation, it is maximized that the active ingredients are penetrated into deeper layer of skin. Cryoelectrophoresis has much more effective penetration than general electrophoresis. Cryogen "Cryoelectrophoresis system" Cryoelectrophoresis system is called Ice therapy that penetrates moisture into skin and maximizes medicines penetration from Meso Therapy without using injector. It brings visible effect of the medicines as ionization and physical penetration are combined to maximize its penetration. Also it has good effects on scalp therapy or edema induced thermal energy and hyperpigmentation because it is based on cryo therapy not thermal energy. Ionized vitamin C is penetrated through (-) current because its property is marked cathode.

12

CRYO-DERM 4. Principle & Effects of Cryoelectrophoresis

Cryo-electrophoresis
Cryo-electrophoresis is way to penetrate Ionized fluid into skin by osmotic pressure happened by electric stimulation. The Electrophoresis which was found in 1808 is an electrokinetic phenomenon that ionized molecule within an electrolyte is moved by another electrode. Ion within electrolyte(water-soluble substance) flows one or both ways depending on ions electric charge. Ionized water-soluble solvent is absorbed surface of skin tissues effectively basing on principle that same electric charges are pushed simultaneously and on the contrary, different electric charges are pulled. Ionized solvent which is electrically pushed by ion is absorbed by capillary circulation and permeation of cell membrane. It is the principle to nourish skin using magnetic property effect. Iontophoresis is technique using a small electric charge to effectively deliver a medicine, watersoluble gel or ampoule through the skin. Adding a cooling system, it brings primary effects of skin protection and soothing and prevents to absorb medicines into blood vessel capillary contraction. Osmotic Pressure Phenomenon In Human body, the cell membrane features selectively permeable because osmosis occurs when there is a partially permeable membrane. The osmotic pressure is defined to be the pressure required to maintain an equilibrium with no net movement of solvent. It is a colligative property meaning that the osmotic pressure depends on the molar concentration of the solute but not on its identity.

Effects of Poles
Cathode - Alkaline Solution Penetration - Skin Activation - Enlargement of Sweat Glands - Relaxation of Skin Tissues - Refining Pores - Improvement of Blood Circulation - Stimulation of Nervous system Alkaline Reaction Effects of Between Poles - Acceleration of Lymph and Blood Circulation - Acceleration of Metabolism - Increase of Temperature Anode - Acid Solution Penetration - Skin Soothing - Contraction of Sweat Glands - Strengthening Skin Tissues - Relief of inflammation - Reduction of Blood Circulation -Relaxation of Nerve Acid Reaction 13

CRYO-DERM 5. Application program 1. Post Peeling Treatment to soothe skin


Sequence 1. Cleansing Applicatio n Temp. Polarity Time 5min. 5min. Cold (0) (+) ion 5min. 5min. 15min. 5min. 2. Soothing 1 CH 3. Ampoule 5. Soothing 4. Pack 5. Finish

Penetration
2 CH Soft ion Cold (0) 1 CH

2. Skin Whitening Care


Sequence 1. 2. 3. Deep 4. Ampoule

5. Massage

6. Pack

7. Finish

Cleansing Circulation Cleansing Application 1 CH Soft ion Temp. Polarity Time 5min. Hot (40) (-) ion 5min. 5min.

Penetration
2 CH Hard ion 1 CH Rejuvenation Cold (-5) (-) ion 5min. 10min. 15min. 5min.

3. Acne Skin Care


Sequence 1. 2. 3. Deep 4. Ampoule Penetration 2 CH Soft ion 1 CH Ion MSG Cold (-5) (+) ion 5min. 5min. 10min. 15min. 5min. 5. Massage 6. Pack 7. Finish Cleansing Circulation Cleansing Application 1 CH Soft ion Temp. Polarity Time 5min. Hot (40) (-) ion 5min.

14

CRYO-DERM 5. Application program

4. Rejuvenation Treatment for aging skin


Sequence 1. Cleansin g Applicatio n 2. Circulatio n 1 CH Soft ion 3. Deep Cleansin g 2 CH Hard ion 4. Ampoule Penetration 5. Massag e 1 CH Rejuven ation Temp. Hot (40) Hot (42) Polarity Time 5min. (-) ion 5min. (-) ion 5min. 10 min. 15 min. 5min. 5min. Cold (-5) 6. Pack 7. Soothing 8. Finish

5. Wrinkle and Skin Elasticity Care


Sequence 1. Cleansin g 2. Circulation 3. Deep Cleansin g 4. Ampoule Penetratio n Applicatio n Temp. 1 CH Soft ion Hot (40) 2 CH Hard ion 1 CH Ion Lift Hot (42) Polarity Time 5 min. (-) ion 5 min. 5 min. (+) ion 5 min. (-) ion 10 min. 15 min. 5min. 5 min. Cold (-5) 5. Massag e 6. Pack 7. Soothing 8. Finish

15

CRYO-DERM 6. Treatment Method

Treatment Method
Facial Treatment (Cryo/Thermo Electrode ) MODE ION SOFT ION HARD ION LIFT ION MSG REJUVENATION LEVEL TIME TEMP COLD HOT 25% 10~15min -10 ~ +10 +35 ~ +45

Facial Treatment (Injection Electrode) MODE ION SOFT ION HARD ION LIFT ION MSG REJUVENATION LEVEL TIME FLOW SPEED 25% 10~15min LOW, MIDDUM, HIGH

16

CRYO-DERM 6. Treatment Method

Facial Treatment

1. Rub down sternocleidomastoid around neck and finish at armpit.

2. Rub up along chin and finish at terminus.

3. Rub up drawing a circle along chin

4. Draw a circle on mouth, eyes area separately.

5. Draw a circle on nose and forehead.

6. Rub from decollete to the whole of face and finish by drainage.

17

CRYO-DERM 6. Treatment Method

Abdominal Treatment (Cryo/Thermo Electrode)


TEMP COLD HOT -10 ~ +10 +35 ~ +45

1.

Draw

circle

in

2.

Massage

on

abdomen

3. Rub both sides toward the navel and finish at the inguinal region.

clockwise direction.

drawing diamond finish at inguinal region.

4. Rub up from side of abdomen to the navel.

5.

Drainage

entirely

at

6.

Draw

circle

in

inguinal region.

clockwise direction.

18

CRYO-DERM 6. Treatment Methods

Legs Treatment (Cryo/Thermo Electrode)


TEMP COLD HOT -10 ~ +10 +35 ~ +45

1. Rub up gastrocnemius of calf and thigh entirely.

2. Massage up in zigzag and drainage area. . toward lymph

3. Draw a circle and rub up toward lymph area.

19

CRYO-DERM 7. Specification

Dimension: 380 X 490 X 130mm Power: DC 12V 6A Weight: 21Kg Output Frequency or Current - ION HARD 3.8KHz, MAX 35mA - ION SOFT 3.8KHz, MAX 28mA - IONLIFT 250Hz, MAX 22mA - LIFTMSG 200Hz, MAX 25mA - REJUVENATION 125Hz MAX 4mA LORD RESISTANCE: 500 Range of Temperature - COOL : 10 ~ -10 1 - HOT: 35 ~ 45 1 Flow Control: HIGH, MIDDLE, LOW Length of Treatment: 5min. ~ 60min. Consumption Power - Stand-by: 0.45A 5.4W - Poccessing: 2.9A 35W (MAX 3.6A 43W) AC Adapter - Input: AC 100-240V, 1.8A, 50-60Hz - Output: DC 12V, 6A Environment Condition of Application/Storage - Processing Temperature : 5 ~ 35 - Processing Humidity : RH 60% - Storage Temperature : 0 ~ 60 - Storage Humidity : RH 80% Protective device - Preventive Circuit for over current - Preventive Circuit for over heat - Zero start Do not use this device for purpose of medical treatment because of its not a medical equipment. * (Over current) (Over heat)

20

CRYO-DERM 8. Warranty Information

9. Warranty Information
Cosmo C&T Limited Warranty What the warranty covers: Cosmo C&T warrants its products to be free from defects in material and workmanship during the warranty period. If a product proves to be defective in material or workmanship during the warranty period, Cosmo C&T will, at its sole option, repair or replace the product with a similar product. Replacement Product or parts may include remanufactured or refurbished parts or components. The replacement unit will be covered by the balance of the time remaining on the customers original limited warranty. Cosmo C&T provides no warranty for the product installed by the customer. Cosmo C&T will report whether we will compensate or not in ten (10) days after you require and the settlement will be reached within twenty one (21) days after you require. Who the warranty protects:

This warranty is valid only for the first consumer purchaser. What the warranty does not cover: 1. 2. Any product on which the serial number has been defaced, modified or removed. Damage, deterioration or malfunction resulting from: A. Accident, misuse, neglect, fire, water, lightning, or other acts of nature, unauthorized product modification, or failure to follow instructions supplied with the product. B. Repair or attempted repair by anyone not authorized by Cosmo C&T. C. Damage to or loss of any programs, data or removable storage media. D. Any damage of the product due to shipment. E. F. Removal or installation of the product. Causes external to the product, such as electric power fluctuations or failure.

G. Use of supplies or parts not meeting Cosmo C&T's specifications. H. Any other cause which does not relate to a product defect. I. 3. Damage to, or abuse of, the coating on the surface of the display. Removal, installation, and set-up service charges.

21

CRYO-DERM 8. Warranty Information How long the warranty is effective:

Cryo_Derm products are warranted for one (1) year for parts and labor.

Warrants
Types of damages When the machine is in need of repair because of capability trouble or functional defect with normal operating within ten (10) days after purchase. When the machine is in need of repair because of capability trouble or functional defect with normal operating within one (1) month after purchase. Repair Possible - 3 times break down with the same problem 4 times break down with the same problem Repair Impossible - Impossible repair with the situation we have parts for repair (within the term of the parts holding) Replacement Within the warranty period Replacement Or Repair- free of charge Replacement Or Repair- free of charge Repair- free of charge Replacement Repair compensation Repair compensation Replacement with depreciation plus 10% of depreciation Impossible repair with the situation we do not have parts for repair (within the term of the parts holding) Replacement Replacement with depreciation After the warranty period

22

CRYO-DERM 8. Warranty Information How to get service: 1. For information on obtaining warranty service, call Cosmo C&T's Customer Support telephone number is: +82-2-338-3789. (Sunny Hwang : hwangsunny@korea.com) 2. To obtain warranty service, please contact Cosmo C&T Customer Support. You will be required to provide A. A copy of the dated sales slip. B. Your name. C. Your address. D. The serial number of the product. E. 3. A description of the problem. Bring or ship the product prepaid in the original container, with the associated accessories, to Cosmo C&T service center. NOTE: Cosmo C&T is not responsible for any returned product without notice in advance. Exclusion of damages: COSMO C&TS LIABILITY IS LIMITED TO THE COST OF REPAIR OR REPLACEMENT OF THE PRODUCT. COSMO C&T SHALL NOT BE LIABLE FOR: 1. DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN THE PRODUCT, DAMAGES BASED UPON INCONVENIENCE, LOSS OF USE OF THE PRODUCT, LOSS OF TIME, LOSS OF PROFITS, LOSS OF BUSINESS OPPORTUNITY, LOSS OF GOODWILL, INTERFERENCE WITH BUSINESS RELATIONSHIPS, OR OTHER COMMERCIAL LOSS, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 2. 3. ANY OTHER DAMAGES, WHETHER INCIDENTAL, CONSEQUENTIAL OR OTHERWISE. ANY CLAIM AGAINST THE CUSTOMER BY ANY OTHER PARTY.