Overall dimensions Processing speed Heating capacity See Dimensions. 1638 mm/minute About 0.453 kW (about 390 kcal/h)

Printer processor section


Weight Exposure conditions Operati on section Exposure engine Approx. 301.73 Kg Controlled with the built-in colorimeter. Display module

iBeam Engine The flatbed scanner recommended by us*1, which is used at iBeam Engine setup, is necessary. To know more about the flatbed scanner, please consult your technical representative. *1. For the suitable flatbed scanner models, see Flatbed scanner (recommended) as explained later.

Print resolution Main scanning: Sub-scanning: Exposure speed Exposure system Print size Paper width: Paper advance length: Paper supply Paper specification Transport system Temperature control Replenishment system 89, 102, 114, 117, 120, 127, 130, 152, 165, 178, and 203 (mm) from 82.5 to 610.0 mm Single magazine type (Dual magazine type and triple magazine type are factory options.) Maximum diameter of paper roll: 250 mm Roller transport system Temperature in each sub-tank is controlled separately. The system calculates the processed amount of paper surface based on the print size and automatically supplies the appropriate amount of replenisher to each tank. Water refilling is performed automatically when the solution level sensors are activated. The upper guides are automatically cleaned at close down checks. 300 dpi 300 dpi 27.94 mm/second Exposure scanning via paper advance

Water refilling Automatic cleaning

Processing tank capacity

Color Developer 8.5 liters Bleach Fixer 8.2 liters Stabilizer 11.6 liters

Processing time

Color Developer 22.3 sec (31.1 sec)*1 Bleach Fixer 27.1 sec (37.8 sec)*1 Stabilizer 43.1 sec (60.1 sec)*1 Dryer 14.5 sec (20.2 sec)*1 *1. Processing time required for some types of paper

Processing temperature

Color Developer 420.3C Bleach Fixer 402.0C Stabilizer 38 - 42C

Replenishment solution tank capacity

Color Developer 6.6 liters Bleach Fixer 6.0 liters Stabilizer 17.1 liters

Effluent tank capacity

Color Developer 4.0 liters Bleach Fixer 4.1 liters Stabilizer 5.8 liters

Collection of effluents Dryer

Two effluents are separately collected by natural dripping. Hot air ink drying method Energy-saving type using automatic power control

Order classification

Max. three orders (Varies depending on the paper size.)*1


*1. Maximum 12 orders when print sorter unit type 1 (option) is installed. Maximum 10 orders when print sorter unit type 2 (option) is installed.

External interface
Ethernet (100Base-TX) Display module interface External AC power outlet Power supply voltage Power capacity 1 port 1 port Outlet type 3 output 200 V to 240 V (conform to the power supply specification) 3A

Flatbed scanner (recommended products)


Manufacturer EPSON A4 flatbed scanner Perfection 4990 Photo Perfection V700 Photo Perfection V750 Actual tank capacities may differ slightly from the volumes shown above. Depending on the combination of paper and processing solution, maximum density of print may be different. For details, contact your place of purchase. Product name

Processing capacity
Repeat processing capacity
Print size (Paper width Paper advance length) 120 mm 82.5 mm 127 mm 89 mm 152 mm 102 mm 203 mm 102 mm 89 mm 127 mm 102 mm 152 mm 127 mm 178 mm 102 mm 203 mm 203 mm 254 mm 203 mm 305 mm 203 mm 610 mm Capacity (Prints/hour)*1 823 781 758 758 622 527 455 402 325 259 96

*1. Calculated according to our criteria. The actual processing capacities may differ depending on various conditions.

Repeat processing capacity


The following is the processing capacity for some types of paper. Print size (Paper width Paper advance length) 120 mm 82.5 mm 127 mm 89 mm 152 mm 102 mm 203 mm 102 mm 89 mm 127 mm 102 mm 152 mm 127 mm 178 mm 102 mm 203 mm 203 mm 254 mm 203 mm 305 mm 203 mm 610 mm Capacity (Prints/hour)*1 688 647 578 578 480 410 356 316 258 217 85

*1. Calculated according to our criteria. The actual processing capacities may differ depending on various conditions.

Required space and dimensions


Space required for installation ! For single magazine type
350 or more*1 2100 or more 250 or more

90 or more 3

Extension table (option)

(Unit: mm)

1390 or more*2

G088213

*1. Extension table (option) not attached *2. The required space is the same even if the print sorter unit (option) is installed. *3. If there is additional space in the installation area, we recommend leaving a space of 205 mm or more between the back of system and wall to facilitate maintenance operations.

! For dual magazine type/triple magazine type


2390 or more 182 or more 250 or more

Dual magazine unit (option) or triple magazine unit (option) (Unit: mm)
G088214

*1. The required space is the same even if the print sorter unit (option) is installed. *2. If there is additional space in the installation area, we recommend leaving a space of 205 mm or more between the back of system and wall to facilitate maintenance operations.

1390 or more*1

90 or more*2

Dimensions
Dual magazine unit (option) or triple magazine unit (option)

1155*3 955

1499.8 1849.8 (Unit: mm) 1957.8


G088215

*1. When the print sorter unit (option) is installed *2. When the processing rack is lifted *3. When the table is raised to the top

1335

13902

640 775 (827*1)

700

526

Power capacity
The values shown here are for installing the power supply. Supply voltage should be within 10% of the specified voltage. The power capacity varies depending on the power supply specification. See the appropriate information for each specification. The three-phase four-wire system is not used in the United States.

IMPORTANT
Use a grounding resistance of 100 or less when grounding this product. For details about 1P2W, see  1P2W. For details about 3P3W, see  3P3W. For details about 3P4W, see  3P4W.

" 1P2W
Supply voltage*1 AC 200 V AC 208 V AC 220 V AC 230 V AC 240 V Power capacity*2 3.6 kVA (18 A) 3.8 kVA (18 A) 3.7 kVA (17 A) 3.8 kVA (17 A) 4.0 kVA (17 A)

Wiring chart
Distribution box Power supply

*3

Circuit breaker (30 A)

Main circuit breaker

1P2W (AC 200 V-240 V)

*3

Ground

Printer processor
G075757

*1. Supply voltage should be within 10% of the specified voltage. *2. This is the capacity required for power supply installation. *3. When installing the film processor, be sure to provide a separate circuit breaker from the printer processor.

NOTE Leakage current value: 11.2 mA (reference value)

" 3P3W
Supply voltage*1 AC 200 V AC 208 V AC 220 V AC 230 V AC 240 V Power capacity*2 3.6 kVA (12 A) 3.8 kVA (13 A) 3.7 kVA (11 A) 3.8 kVA (11 A) 4.0 kVA (11 A)

Wiring chart
Distribution box Power supply

*3

Circuit breaker (20 A)

3P3W Main circuit breaker (AC 200 V-240 V)

*3

Ground

Printer processor

G075758

*1. Supply voltage should be within 10% of the specified voltage. *2. This is the capacity required for power supply installation. *3. When installing the film processor, be sure to provide a separate circuit breaker from the printer processor.

NOTE Leakage current value: 11.2 mA (reference value)

" 3P4W
Supply voltage*1 AC 346 V AC 380 V AC 400 V AC 415 V Power capacity*2 3.6 kVA (9 A) 3.7 kVA (8 A) 3.8 kVA (8 A) 4.0 kVA (9 A)

Wiring chart
Distribution box
*3

Power supply

Circuit breaker (20 A)


*3

Main circuit breaker

3P4W (AC 346 V-415 V)

Ground

Printer processor
G075759

*1. Supply voltage should be within 10% of the specified voltage. *2. This is the capacity required for power supply installation. *3. When installing the film processor, be sure to provide a separate circuit breaker from the printer processor.

NOTE Leakage current value: 11.2 mA (reference value)

Standard equipment
Printer section
Item Castors Magazine*1 Table height adjust function Correction value printing unit (CVP) Display module *1. The paper width can be selected from the following: 89, 102, 114, 117, 120, 127, 130, 152, 165, 178, and 203 (mm) Attached 1 Built-in Installed Installed Status

Paper processor section


Item Remote effluent tank Effluent level alarm (1 per tank) Dryer overheat prevention system Solution overheat prevention system Processing tank level alarm Circulation pump stop alarm Dryer temperature setting function (for each paper magazine) Drive and dryer automatic stop function Castors Print conveyor unit Control strip holder Surge absorber (surge protection circuit) Automatic cleaning Replenishment solution remaining amount alarm (1 per tank) Automatic water refilling unit Incorrect cartridge loading prevention function Automatic solution mixing Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Attached Installed 1 Built-in Built-in Built-in Built-in Built-in Built-in Status

Standard accessory
Printer processor section
Name C-ring #4 C-ring #6 Vinyl hose (inside diam. 9 mm outside diam. 13 mm length 1500 mm) Slow-blow fuse (3.15 A) Slow-blow fuse (6.3 A) Slow-blow fuse (10 A) Slow-blow fuse (5 A) Glass tube fuse (2 A) Check date entry sticker Stick Cleaning sheet Cleaning wiper Lower turn belt Lower turn belt (3) Washing bottle (500 ml) Measuring hose (1) Quantity 5 5 1 2 2 2 2 2 1 1 1 1 1 1 1 1 Remarks Accessory for processing rack Accessory for processing rack For treating effluent Spare item Spare item Spare item Spare item Spare item Sticker to write the date that float switch operation was checked For checking the operation of the float switch in the processing tank Cloth for cleaning the colorimeter unit Cleaning supply Accessory for processing rack Accessory for processing rack For cleaning processing rack For Color Developer replenishment solution, Bleach Fixer and Stabilizer replenishment solution For measuring replenishment solution (PS1 and PS2) For measuring replenishment solution (PS3 and PS4) For measuring test prints for iBeam tuning Power supply cable for PC Power supply cable for monitor Cross type Prevents auxiliary solutions from dripping into the CD solution when removing processing racks, etc. (The maintenance cover is for preventing processing solution from adhering to the processor loading unit.) Oil for lubricating the dryer drive chain

Measuring hose (2) Measuring hose (3) Paper holder Plug code (1 m) Plug code (2.5 m) LAN cable (0.7 m) Flat cable clamp Anti-contamination cover (includes the maintenance cover)

1 1 1 1 1 1 5 one each

Chain Oil

10

Options (Printer)
Some of the following options may not be available in some countries and areas. For details, contact your place of purchase.

Printer section
Option No. Z804937-01 H086044-00 Z811139-01 Name DP bag hanger (DH-6) Ink ribbon cassette Dual magazine unit CVP ink ribbon Unit compatible with the dual magazine type The paper magazine is required separately. (available as factory option) Unit compatible with the triple magazine type The paper magazine is required separately. (available as factory option) Mainly used to place the A4 flatbed scanner on. Indicates the number of prints. Table to place the display monitor on Monitor arm with which you can freely change direction of the display. The cover to hide the rear side of the machine. When the table is raised, a cabinet can be installed under the table. For connecting the scanner (1.5 m) Explanation Hanger for holding developed films and DP bags.

Z811140-01

Triple magazine unit

Z811135-01 Z810651-01 Z811137-01 Z811114-01 Z811147-01 Z811191-01 I068490-00

Expansion table Counter unit Monitor table LCD monitor arm Rear cover Storage cabinet Plug cord

Paper magazine
Option No. Z811196-02 Z811196-03 Z811196-04 Z811196-05 Z811196-06 Z811196-08 Z811196-09 Z811196-10 Z811196-11 Z811196-12 Z811196-13 Name Paper magazine, 89 mm Paper magazine, 102 mm Paper magazine, 114 mm Paper magazine, 117 mm Paper magazine, 120 mm Paper magazine, 127 mm Paper magazine, 130 mm Paper magazine, 152 mm Paper magazine, 165 mm Paper magazine, 178 mm Paper magazine, 203 mm Explanation Include Magazine spindle unit 1 and handle.

11

Options (Paper processor)


Some of the following options may not be available in some countries and areas. For details, contact your place of purchase.

Paper processor section


Option No. C008075-01 B011625-01 C101570-01 A202513-01 H049014-00 L005253-00 Z810657-01 Z811175-01 H089016-00 Floor tray Rack transportation tank Turn rack vat Filler Effluent tank Measuring cylinder Minute meter unit Sorter modification kit (10 orders) Cleaning sheet Name Explanation Placed underneath the system to prevent the floor from becoming dirty. Used to transport wet processing racks. Container for immersing the upper guide in water. 5-liter measuring pitcher Collects effluent that overflows from the processing tanks. (20 liters) Used to measure replenishment solution, etc. (200 ml). Displays the system operating time. Modifies the print sorter unit to support 10 orders (only when print sorter unit type 1 is installed) Used to clean the pressure roller of the colorimeter unit.It should be cleaned every six months. Three sheets included. Allows prints to be sorted by order (12-order type). Allows prints to be sorted by order (10-order type). Unit to process the control strip without using the control strip leader.

Z811171-01 Z811172-01 Z811150-01

Print sorter unit (type 1) Print sorter unit (type 2) Control strip auto loading unit

12

Commercially available items to be prepared by the customer


The items below are required according to the installation environment of the customers. They should be prepared by customers if necessary. Item HUB Remarks When several systems are connected to the PC, a hub is necessary. (Should be with the required number of 100BASE-TX ports.) Cross type Straight type The cable of 0.7 m is supplied as a standard accessory. If the longer cable is required, prepare the longer cable. Prepare this when connecting the system using a HUB.

LAN cable

13

Installation requirements
This system is to be used in a location with a relative humidity from 30 to 75% and temperature from 15 to 30C (59 to 86F). The light source for this system should be a natural light color, and the light intensity should be between 300 and 400 lux. If there are lights near to the system, they must be screened. In particular, if the product is installed near a window, use curtains or blinds to block direct sunlight from the product. Do not install the product in a place where the operator is exposed to direct sunlight. Make sure the display monitor is located away from direct sunlight or other bright light sources. Avoid installing the product in areas with high dust levels or subject to vibration. Do not raise or lower the room temperature quickly. Raising the temperature quickly can cause condensation inside the system, which leads to problems such as lens fogging, paper jam, and malfunctions in the electronics and PCBs. Because the system uses liquids during normal operation, please make sure that the floor and walls are waterproof for safety reasons. In addition, we recommend installing a sink or drain in the room to facilitate washing racks. Castors are for moving the system. Once the system has been installed, be sure to fix it in place with the adjusters or jack bolts. If the level difference of the floor on which the system is installed (the height difference between jack bolts) is 10 mm or more, a plate or shim should be used to adjust the level. Use this system in a DC magnetic field (earth magnetic field, etc.) of 0.6G*1 or less and AC magnetic field (power source magnetic field, etc.) of 0.06G*1 (rms) or less.
*1. 0.6G = 60T, 0.06G = 6T

The system is programmed with default values prior to shipment. These values may differ depending on the environment and operating conditions. Change them as necessary. The maximum permissible system impedance Zmax of this system is 0.063+j0.039, supplied from a power distribution system having a rated voltage of 400/230 V. This system is connected only to a supply of that impedance or less. Determine the connection to a power supply in consultation with the supply power company. This equipment complies with EN61000-3-12.

Subject to change without notice.

14

You might also like