MAN Diesel & Turbo

Main Engine Room Data


www.manbw.dk/ceas/erd

Main Engine Project name Project type Project number Date Yard Country Made by Department

7S50MC-C8-TII IMO-NOx Tier II compliant S2065 Tier II Mk8

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Specified Main Engine and Ratings

Further reading: www.manbw.com/Papers/Basic_Principles_Of_Ship_Propulsion.pdf p. 20-29

Specified Main Engine and Ratings


Turbocharger/engine version Type of propeller Cylinder oil lubricator type Sulphur content in fuel high eff.t/c Fixed pitch Alpha ACC (power control) 3.0

Nominal Maximum Continuous Rating (NMCR)


Nominal engine power Nominal engine speed Mean effective pressure Mean piston speed
(NMCR)
kW r/min bar m/s

11,620 127.0 20.0 8.5

Specified MCR (SMCR)


Engine shaft power Engine speed Mean effective pressure Mean piston speed
kW r/min bar m/s

11,060 127.0 19.0 8.5

Optimising Point
Optimising point Engine shaft power Engine speed
% of SMCR kW r/min

100.0 11,060 127.0

Normal Continuous Rating (NCR)


Service power Engine shaft power Engine speed
% of SMCR kW r/min

90.0 9,954 122.6

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 2

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Ambient reference conditions


ISO Conditions
Scavenge air coolant temperature Ambient air temperature Barometric pressure Exhaust gas back pressure
C C mbar mmWC

25.0 25.0 1,000 300

Tropical conditions
Sea water temperature Central water temperature Ambient air temperature Barometric pressure
C C C mbar

32.0 36.0 45.0 1,000

Specified ambient conditions


Scavenge air coolant temperature Ambient air temperature Barometric pressure
C C mbar

10.0 10.0 1,000

Further reading: www.manbw.com/Papers/Influence_Of_Ambient_Temperature_Conditions.pdf p. 7-11

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 3

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Expected SFOC, Lube Oil Consumption, Air and Exhaust gas data
Tolerances
Reference LCV of fuel SFOC tolerance (optimising point) Exhaust gas amount tolerance Exhaust gas temperature tolerance
kJ/kg % % C

42,700 +/- 5 +/- 5 -/+ 15

ISO ambient conditions


Specific Fuel Oil Consumption
Nominal Maximum Continuous Rating (NMCR) SMCR Optimising point NCR
g/kWh g/kWh g/kWh g/kWh

175.0 173.6 173.6 171.5

Exhaust Gas Amount


SMCR Optimising point NCR
kg/h kg/h kg/h

98,600 98,600 91,700

Exhaust Gas Temperature


SMCR Optimising point NCR
C C C

244 244 232

Air consumption
SMCR Optimising point NCR
kg/s kg/s kg/s

26.9 26.9 25.0

Tropical ambient conditions


Specific Fuel Oil Consumption
SMCR Optimising point NCR
g/kWh g/kWh g/kWh

176.8 176.8 174.7

Exhaust Gas Amount


SMCR Optimising point NCR
kg/h kg/h kg/h

92,600 92,600 86,100

Exhaust Gas Temperature


SMCR Optimising point NCR
C C C

277 277 265

Air consumption
SMCR Optimising point NCR
kg/s kg/s kg/s

25.2 25.2 23.4

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 4

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Specified ambient conditions


Specific Fuel Oil Consumption
SMCR Optimising point NCR
g/kWh g/kWh g/kWh

170.7 170.7 168.6

Exhaust Gas Amount


SMCR Optimising point NCR
kg/h kg/h kg/h

101,800 101,800 94,800

Exhaust Gas Temperature


SMCR Optimising point NCR
C C C

219 219 207

Air consumption
SMCR Optimising point NCR
kg/s kg/s kg/s

27.8 27.8 25.9

Consumption of Lubrication Oils


System Oil
Consumption per 24 hours
kg/24h

31.5

Cylinder Oil (SLOC)


SMCR Optimising point NCR
g/kWh g/kWh g/kWh

0.78 0.78 0.78

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 5

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Necessary Capacities of Auxiliary Machinery (SMCR)


Layout of Systems
Cooling water system Seawater inlet temperature Central water outlet temperature Tropical ambient air temperature Lubricating oil system Separate camshaft L.O. system Separate turbocharger L.O. system
C C C

Central cooling 32.0 36.0 45.0

No No

Pumps
Fuel oil circulating pump
Flow capacity Pump head
m/h bar

6.7 6.0

Fuel oil supply pump


Flow capacity Pump head
m/h bar

2.9 4.0

Jacket water pump


Flow capacity Pump head
m/h bar

97.0 3.0

Central cooling water pump


Flow capacity Pump head
m/h bar

300.0 2.5

Seawater pump
Flow capacity Pump head
m/h bar

345.0 2.5

Lubricating oil pump


Flow capacity Pump head
m/h bar

235.0 4.1

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 6

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Coolers
Scavenge air coolers
Heat dissipation Central water flow
kW m/h

4,470 180

Lubricating oil cooler


Heat dissipation Lubricating oil flow Central water flow
kW m/h m/h

870 235 120

Jacket water cooler


Heat dissipation Jacket water flow Central water flow
kW m/h m/h

1,630 97 120

Central cooler
Heat dissipation Central water flow Seawater flow
kW m/h m/h

6,970 300 345

Fuel oil preheater


Heat capaity 175 kW The pump heads stated are for guidance only, and depend on the actual pressure drop across coolers, filters, etc. in the systems. Pertaining cooling water flow diagram, temperatures, viscosities and pressures for pumps and coolers, see "Engine Project Guide".

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 7

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Starting Air System, Engine dimensions, Tanks, etc.


Starting air system, 30.0 bar g
Reversible engine
Receiver volume (12 starts) Compressors (total)
m m/h

2 x 4.50 270.0

Main engine dimensions


Dimensions
Length excl. tuning wheel, tanktop Min length excl. tuning wheel, c/l Max length incl. tuning wheel, c/ll Cylinder distance Width of bedplate Distance, foot - crankshaft c/ll
mm mm mm mm mm mm

7,624 7,624 8,124 850 3,150 1,085

Overhaul
Normal lift, c/l - crane hook Crane capacity, normal lifting procedure Double jib crane, c/l - deck beam Crane capacity, double jib crane
mm t mm t

9,000 2.00 8,250 2 x 1.60

Weight
Weight of main engine, dry 238.0 t Weight of water and oil in engine 2.0 t The real engine length at crankshaft centreline level (c/l) may be between the above min and max lengths, and depends on the vibration conditions of the main engine and shaft system, i.e. on whether a vibration damper need to be installed. The mass can vary up to 10% depending on the design and options chosen

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 8

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Dimensions of tanks, centrifuges and aux. blowers


Fuel oil system
Marine diesel oil service tank, 4 hour m Fuel oil settling tanks, 2 x 12 hour m Fuel oil centrifuge, 98 C l/h Fuel oil service tank, 6 h/95 C m The capacity of the F.O. centrifuge(s) is for guidance only. Actual capacity should be given by the maker 9.0 2 x 27.0 3,137 14.0

Lubrication oil system


Lube oil storage tanks,(2x3 months) Lube oil centrifuge, 95 C Lube oil bottom (sump) tank, appr.
m l/h m

2 x 3.8 1,580 14.2

Cylinder oil system


Cylinder oil storage tanks Cylinder oil service tank
m m

2 x 25.0 1.9

Various drain tanks


Stuffing box drain tank Scavenge air drain tank
m m

0.30 0.70

Air cooler cleaning unit


Air cooler cleaning tank Capacity of pump
m m/h

0.30 1.00

Jacket water
Expansion tank for jacket water
m

1.00

Auxiliary blower(s)
Electric motor rating of aux.blower(s)
kW

2 x 44

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 9

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Tables of SFOC and Exhaust Gas Data


Part Load Data at ISO Ambient Conditions
Load
% of SMCR 100.0 95.0 90.0 85.0 80.0 75.0 70.0 65.0 60.0 55.0 50.0 45.0 40.0 35.0

Power
kW 11,060 10,507 9,954 9,401 8,848 8,295 7,742 7,189 6,636 6,083 5,530 4,977 4,424 3,871

Speed
r/min 127.0 124.8 122.6 120.3 117.9 115.4 112.8 110.0 107.1 104.1 100.8 97.3 93.6 89.5

SFOC
g/kWh 173.6 172.4 171.5 170.8 170.6 170.7 170.9 171.4 172.1 173.0 174.0 175.3 176.7 178.4

Exh. gas amount


kg/h 98,600 95,200 91,700 88,200 84,400 80,500 76,400 72,100 67,600 62,800 57,900 52,700 47,300 41,700

Exh. gas temp.


C 244.3 237.5 232.1 228.1 225.5 224.3 224.5 226.1 229.1 233.5 239.3 247.4 257.0 265.6

Ambient air suction temperature: 25.0 C Cooling water temperature: 25.0 C

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 10

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Part Load Data at Tropical Ambient Conditions


Load
% of SMCR 100.0 95.0 90.0 85.0 80.0 75.0 70.0 65.0 60.0 55.0 50.0 45.0 40.0 35.0

Power
kW 11,060 10,507 9,954 9,401 8,848 8,295 7,742 7,189 6,636 6,083 5,530 4,977 4,424 3,871

Speed
r/min 127.0 124.8 122.6 120.3 117.9 115.4 112.8 110.0 107.1 104.1 100.8 97.3 93.6 89.5

SFOC
g/kWh 176.8 175.6 174.7 174.0 173.8 173.8 174.1 174.6 175.3 176.2 177.3 178.6 180.1 181.7

Exh. gas amount


kg/h 92,600 89,400 86,100 82,800 79,300 75,600 71,800 67,700 63,500 59,000 54,300 49,400 44,400 39,100

Exh. gas temp.


C 277.4 270.6 265.2 261.2 258.6 257.4 257.6 259.2 262.2 266.6 272.4 280.7 290.9 299.9

Ambient air suction temperature: 45.0 C Cooling water temperature: 36.0 C

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 11

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Part Load Data at Specified Ambient Conditions


Load
% of SMCR 100.0 95.0 90.0 85.0 80.0 75.0 70.0 65.0 60.0 55.0 50.0 45.0 40.0 35.0

Power
kW 11,060 10,507 9,954 9,401 8,848 8,295 7,742 7,189 6,636 6,083 5,530 4,977 4,424 3,871

Speed
r/min 127.0 124.8 122.6 120.3 117.9 115.4 112.8 110.0 107.1 104.1 100.8 97.3 93.6 89.5

SFOC
g/kWh 170.7 169.5 168.6 168.0 167.7 167.8 168.1 168.6 169.2 170.1 171.1 172.4 173.8 175.4

Exh. gas amount


kg/h 101,800 98,300 94,800 91,100 87,200 83,200 79,000 74,500 69,800 64,900 59,800 54,400 48,800 43,100

Exh. gas temp.


C 218.8 212.0 206.6 202.6 200.0 198.8 199.0 200.6 203.6 208.0 213.8 221.7 230.9 239.2

Ambient air suction temperature: 10.0 C Cooling water temperature: 10.0 C

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 12

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo


Jacket water cooler heat -15/+0% (kW) Main lubrication oil heat (kW) Condensed water (t/24h)

Tables of Cooler Heat


Engine load (% SMCR) Engine power (kW) Engine speed (r/min) Scavenge air amount +/- 5% (kg/h) Scavenge air pressure (bar abs) Scavenge air temperature BEFORE air cooler (C) Scavenge air temperature AFTER air cooler (C) Scavenge air cooler heat (kW)
Air suction temperature: 25.0C Cooling water temperature: 25.0C

ISO Ambient Conditions


% kW r/min

kg/h

bar (abs)

kW

kW

kW

t/24h

100.0 95.0 90.0 85.0 80.0 75.0 70.0 65.0 60.0 55.0 50.0 45.0 40.0 35.0 30.0 25.0

11,060 10,507 9,954 9,401 8,848 8,295 7,742 7,189 6,636 6,083 5,530 4,977 4,424 3,871 3,318 2,765

127.0 124.8 122.6 120.3 117.9 115.4 112.8 110.0 107.1 104.1 100.8 97.3 93.6 89.5 85.0 80.0

96,700 93,400 90,000 86,600 82,900 79,100 75,100 70,900 66,500 61,700 56,900 51,800 46,500 41,000 35,300 29,500

3.9 3.7 3.6 3.4 3.2 3.1 2.9 2.7 2.5 2.4 2.2 2.0 1.9 1.7 1.6 1.4

198.0 191.0 184.0 177.0 169.0 162.0 154.0 145.0 136.0 127.0 117.0 107.0 96.0 85.0 74.0 64.0

37.0 36.0 34.0 33.0 32.0 31.0 30.0 29.0 29.0 28.0 27.0 27.0 26.0 26.0 33.0 32.0

4,350 4,060 3,770 3,480 3,190 2,890 2,590 2,300 2,000 1,710 1,430 1,160 910 680 480 320

1,440 1,380 1,330 1,280 1,220 1,170 1,120 1,060 1,010 960 900 850 800 740 690 640

770 760 750 740 720 710 690 670 650 620 600 570 540 510 470 430

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Tropical Ambient Conditions


100.0 95.0 90.0 85.0 80.0 75.0 70.0 65.0 60.0 55.0 50.0 45.0 40.0 35.0 30.0 25.0 11,060 10,507 9,954 9,401 8,848 8,295 7,742 7,189 6,636 6,083 5,530 4,977 4,424 3,871 3,318 2,765 127.0 124.8 122.6 120.3 117.9 115.4 112.8 110.0 107.1 104.1 100.8 97.3 93.6 89.5 85.0 80.0

Air suction temperature: 45.0C

Cooling water temperature: 36.0C

90,600 87,600 84,400 81,200 77,800 74,200 70,500 66,400 62,300 57,900 53,300 48,500 43,600 38,400 33,100 27,700

3.8 3.6 3.4 3.3 3.1 3.0 2.8 2.6 2.5 2.3 2.1 2.0 1.8 1.7 1.5 1.4

224.0 217.0 210.0 202.0 194.0 186.0 178.0 169.0 159.0 150.0 140.0 129.0 117.0 106.0 94.0 84.0

48.0 47.0 45.0 44.0 43.0 42.0 41.0 40.0 40.0 39.0 38.0 38.0 37.0 37.0 44.0 43.0

4,470 4,180 3,880 3,590 3,290 2,990 2,690 2,390 2,090 1,800 1,510 1,230 970 740 530 370

1,470 1,410 1,360 1,300 1,250 1,190 1,140 1,080 1,030 980 920 870 810 760 700 650

780 770 760 750 730 720 700 680 660 640 610 580 550 520 480 440

40.1 39.9 39.3 38.3 37.0 35.3 33.3 31.0 28.4 25.6 22.5 19.3 15.9 12.5 2.1 1.2

Specified Ambient Conditions


100.0 95.0 90.0 85.0 80.0 75.0 70.0 65.0 60.0 55.0 50.0 45.0 40.0 35.0 30.0 25.0 11,060 10,507 9,954 9,401 8,848 8,295 7,742 7,189 6,636 6,083 5,530 4,977 4,424 3,871 3,318 2,765 127.0 124.8 122.6 120.3 117.9 115.4 112.8 110.0 107.1 104.1 100.8 97.3 93.6 89.5 85.0 80.0

Air suction temperature: 10.0C

Cooling water temperature: 10.0C

99,900 96,500 93,100 89,500 85,700 81,800 77,700 73,300 68,700 63,900 58,900 53,500 48,000 42,400 36,500 30,500

3.9 3.8 3.6 3.4 3.3 3.1 2.9 2.7 2.6 2.4 2.2 2.0 1.9 1.7 1.6 1.4

176.0 169.0 162.0 156.0 148.0 141.0 133.0 125.0 117.0 108.0 99.0 89.0 78.0 68.0 57.0 48.0

22.0 21.0 19.0 18.0 17.0 16.0 15.0 14.0 14.0 13.0 12.0 12.0 11.0 11.0 18.0 17.0

4,290 4,010 3,730 3,440 3,150 2,860 2,570 2,270 1,980 1,700 1,420 1,150 900 670 480 320

1,410 1,360 1,310 1,260 1,200 1,150 1,100 1,050 990 940 890 840 780 730 680 630

760 750 740 720 710 690 680 660 640 610 590 560 530 500 470 430

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Scavenge air pressue and air cooler data for guidance only - not to be used for dimensioning of turbochargers and scavenge air coolers. See the design specification of the engine.

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 13

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Typical noise and vibration levels


SMCR
Octave band centre freq. A) Exhaust gas system (2x10 Pa) B) Standard noise reduction (2x10-5 Pa) C) Additional noise reduction (2x10-5 Pa) D) Structureborne vibrations (5x10-8 m/s)
-5

31.5 Hz 63.0 Hz

125 Hz

250 Hz

500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz dB(Lin)

dB(A)

Max dB(A)

125.0 98.5 98.5 79.0

120.0 97.7 97.4 77.5

113.0 97.8 96.0 74.6

106.3 97.8 95.8 71.8

104.1 97.5 95.8 71.3

101.5 98.4 96.5 65.8

93.6 99.7 97.7 60.0

83.0 97.8 95.0 51.8

73.5 92.0 87.5 44.7

126.4 107.4 105.8 -

106.4 105.0 102.8 -

107.4 105.8 -

NCR (90.0% of SMCR)


Octave band centre freq. A) Exhaust gas system (2x10 Pa) B) Standard noise reduction (2x10 Pa) C) Additional noise reduction (2x10-5 Pa) D) Structureborne vibrations (5x10 m/s)
-8 -5 -5

31.5 Hz 63.0 Hz

125 Hz

250 Hz

500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz dB(Lin)

dB(A)

Max dB(A)

123.5 97.7 97.7 78.1

118.5 96.8 96.5 76.6

111.0 97.1 95.2 73.7

104.6 97.0 95.1 71.0

103.2 96.7 94.9 70.3

100.3 97.4 95.5 64.7

90.9 98.3 96.3 58.9

80.5 95.8 92.9 50.5

71.2 89.8 85.4 43.5

125.0 106.3 104.8 -

105.0 103.6 101.4 -

106.3 104.8 -

Notes
A) Sound pressure levels from exhaust gas system. The expected sound pressure level at 1 metre from the edge of the exhaust gas pipe opening at an angle of 30 degrees to the direction of the gas flow and valid for a normal exhaust gas system - but without a boiler and silencer. B) Airborne sound pressure levels - with standard noise reduction countermeassures. Expected mean sound pressure octave spectrum levels, i.e. the average spartial noise values at a distance of 1 metre from the engine. Prescribed measuring surface area is 105.8 m. C) Air-borne sound pressure levels - with additional noise reduction countermeassures. Expected mean sound pressure octave spectrum levels, i.e. the average spatial noise values at a distance of 1 metre from the engine. Prescribed measuring surface area is 105.8 m. Addtional noise reduction countermeasuers, e.g.: 1. Extra good turbocharger air intake silencer(s) 2. External sound insulation of scavenge air receiver 3. External sound insulation of scavenge air cooler(s). Other additional noise reduction countermeasures are also available. The noise figures given are in accordance with the CIMAC recommendations for measurements of the overall noise for reciprocating engines. The average levels will, depending on the actual engine room configuration, be 1-5 dB higher when the engine is installed in the engine room. D) Structureborne vibration levels Expected mean velocity octave spectrum levels at the engine base plate as installed on board the ship. Based on an average engine foundation of a ship, and may only be used as a rough estimate as the velocity levels will depend on the actual foundation used.If the vibration velocity levels are referred to 10-9 m/s instead of 5x10-8 m/s, the calculated dB figures will be 34.0 dB higher than above stated.

Further reading: www.manbw.com/Papers/Diesel_Engines_And_the_Enviroment_Noise.pdf

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 14

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

Alternative Engines and Turbochargers, Further Reading


Alternative Tier II engines
SMCR: 11,060 kW at 127.0 rpm. Optimization point: 100.0
Nominal MCR Power
[kW]

Specified MCR RPM Lowest opt point


[% SMCR]

Engine room SFOC (ISO)


[g/kWh]

Opt point
[% SMCR]

Overhaul height H1
[mm]

Overhaul height H3
[mm]

Lengthmin
[mm]

Width
[mm]

Weight
[t]

11S42MC7-TII 12S42MC7-TII 7S50MC-C7-TII 7S50MC-C8-TII 7S50ME-B8-TII 7S50ME-C7-TII 7S50ME-C8-TII 8S50MC6-TII 8S50MC-C7-TII 8S50MC-C8-TII 8S50ME-B8-TII 8S50ME-C7-TII 8S50ME-C8-TII
= selected engine

11,880 12,960 11,060 11,620 11,620 11,060 11,620 11,440 12,640 13,280 13,280 12,640 13,280

136.0 136.0 127.0 127.0 127.0 127.0 127.0 127.0 127.0 127.0 127.0 127.0 127.0

100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0

100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0

178.9 177.3 175.0 173.6 169.6 172.0 170.6 175.0 171.3 170.0 166.0 168.3 167.0

8,000 8,000 9,000 9,000 9,000 9,000 9,000 8,850 9,000 9,000 9,000 9,000 9,000

7,300 7,300 8,250 8,250 8,250 8,250 8,250 8,100 8,250 8,250 8,250 8,250 8,250

10,168 10,916 7,624 7,624 7,624 7,624 7,624 8,840 8,474 8,474 8,474 8,474 8,474

2,670 2,670 3,150 3,150 3,150 3,150 3,150 2,950 3,150 3,150 3,150 3,150 3,150

249 269 238 238 235 224 224 288 273 273 265 257 257

= lowest value

= highest value

Alternative Turbochargers
Central Seawater cool. water pump flow pump
[m/h] [m/h]

Lub. oil flow


[m/h]

Lub. oil cooler heat diss.


[kW]

oil flow
[m/h]

Jacket water Central cooler cooler flow, c.w. flow c.w. heat diss. c.w. flow s.w. flow
[m/h] [m/h] [kW] [m/h] [m/h]

Min. motor rating for aux blowers


[kW]

1 x TCA66-21 2 x TCA44-23 2 x TCA55-21 1 x A175-L35 1 x TPL77-B12 2 x A165-L35 2 x TPL73-B11 1 x MET60MB 1 x MET60MA 2 x MET42MB 2 x MET42MA = selected turbocharger

300 300 300 300 300 305 305 300 300 300 300

345 345 345 345 345 345 350 345 345 345 345

235 235 240 235 235 240 240 235 235 235 235

870 880 900 910 920 920 970 900 890 900 890

235 235 240 235 235 240 240 235 235 235 235

120 120 120 120 120 125 125 120 120 120 120

120 120 120 120 120 125 125 120 120 120 120

6,970 6,980 7,000 7,010 7,020 7,020 7,070 7,000 6,990 7,000 6,990

300 300 300 300 300 305 305 300 300 300 300

345 345 345 345 345 345 350 345 345 345 345

2 x 44.0 2 x 44.0 2 x 44.0 2 x 44.0 2 x 44.0 2 x 44.0 2 x 44.0 2 x 44.0 2 x 44.0 2 x 44.0 2 x 44.0

s.w. = seawater

c.w. = central water

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo

Page 15

7S50MC-C8-TII with 1 x TCA66-21 SMCR: 11,060 kW at 127.0 RPM Opt. point: 100.0 % IMO NOx Tier II comp.

Engine Room Dimensioning www.manbw.dk/ceas/erd

MAN Diesel & Turbo

References and Further Reading


www.manbw.com/Papers/Exhaust_Gas_Emission_Control_Today_and_Tomorrow.pdf (Aug. 19th 2008)
Regulations, impact on engine, current and future emission control methods, fuels, waste heat recovery, Tier I, Tier II

www.manbw.com/Papers/Basic_Principles_Of_Ship_Propulsion.pdf (Feb. 8th 2006)


Layout/load diagrams, running points, combinator curves, propeller propulsion, propeller types/dimensions, flow and operating conditions, ship types, hull resistance/forms, load lines.

www.manbw.com/Papers/Influence_Of_Ambient_Temperature_Conditions.pdf (Mar. 16th 2006)


Influence of ambient temperature conditions on engine operation, engine room ventilation, special high/low temperature precautions, adjustable bypass system.

www.manbw.com/Papers/Propulsion_Trends_in_Bulk_Carriers.pdf (Oct. 4th 2007)


Greater market demand for bulk carriers, double skinned hull design, sizes and classes, propulsion power demand, average bulk carriers, Handysize, Panamax,

www.manbw.com/Papers/
Technical papers on propulsion trends in tankers/bulkers/shuttle tankers/container ships, exhaust gas boiler, emission control, LNG carrier, ME-GI engines, Alpha ACC, engine noise, vibration aspects.

Local time CPH (GMT + 01:00): May 5th 2010 16:49 This report is for guidance only and can only be used in the initial stages of projects. The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo