You are on page 1of 4

DIAMOND Fiber Optic Components

CABLE ASSEMBLIES AND ADAPTERS

Break-Out

SINGLE MODE PC/APC MULTIMODE PC

DIAMONDs BREAK-OUT cabling system is an easy and secure solution to perform fiber optic installations with no need for expensive tools and equipment. The Break-Out trunk cable contains fiber of the customers choice. Each fiber is terminated with the connectors requested by the customer. For delivery, DIAMONDs BREAK-OUT cabling system is well protected in an especially designed packaging, which includes measuring protocols of each channel. no rodent protection is demanded the trunk cable is max. 80m long preterminated cabling systems are preferred you want to save the costs for splicing and measuring equipment a manufacturer warranty is desired
E-2000 Break-Out

This solution is recommended where. (Application area)

FEATURES AND BENEFITS


Customer-specific cable length available Fiber types: MM 50 m, MM 62.5 m and SM 9 m Available in a wide assortment of connector styles including: E-2000, F-3000, FC, SC, ST, MT-RJ, .... Armored Cable with Pulling-eye (optional) Color coding for channel identification Supplied as air ring or on reel Attenuations test report included

SPECIFICATIONS
Connector: Cord Length: Cord identification: - according to IEEE and ITU Standards - from 0.5m to 10m available - according color code Swisscom/DIN/IEC/TIA Standard (int.) - optional with channel numbering - optional connecteur protection
MM 50 m 2.7 (850nm) 0.7 (1300nm) -10 +60* -10 +60* MM 62.5 m 3.0 (850nm) 0.7 (1300nm) UNITS dB/km

Cord protection:
CABLE TYPE max. Insertion Loss (IL) Operating temperature Storage temperature

SM 9 m 0.36 (1310nm) 0.25 (1550nm)

C C

* May be further limited by cable specifications. NOTE Please refer to the connector datasheets for performance specifications.

DIAMOND SA Via dei Patrizi 5 CH-6616 Losone - Switzerland Tel. +41 91 785 45 45 Fax +41 91 785 45 00 e-mail info@diamond-fo.com

www.diamond-fo.com

Specifications subject to change without notice


BDD 1900472 07_12

Break-Out

CABLE SPECIFICATIONS
CABLE Number of fibers Diameter of cable Tensile Load Bend Radius Crush Resistance 2 7.4 1000 95 100 BREAK-OUT CABLE 4 7.4 1000 95 100 6 9.0 1000 120 100 8 10.2 1000 145 100 12 11.2 1000 165 100 UNITS Pieces mm N mm N/cm EN 60764-1-2E1 EN 60764-1-2E11 EN 60764-1-2E3
E-2000 Break-Out Protection E-2000 Break-Out

TEST CONDITIONS

Cable type: - Indoor applications, up to 12 Fibers (FR/LS0H) Fiber type: - MM 50m or MM62.5/125m - MM 50m OM3 - SM 9m G.652, G.652c, G.652d, G.652e - SM 9m G.655

Fiber count: 2/4/6/8/10/12 Fibers (others available upon request)

ORDER INFORMATION
END A END B

Cord A LA

Break-Out cable

Cord B LB

END A
Connector type Conn. count max. 12 Pcs. Cord Length L A min. 0.5 m max. 10 m Staggering (40 mm)

Break-Out Cable
Cable
Cable type Fibers Fiber type

END B*
Connector type Conn. count max. 12 Pcs.

q No Assembly
Cord Lenght L B min. 0.5 m max. 10 m Staggering (40 mm)

q q q q q q q q q q q

E-2000 F -3000 FC SC ST MT-RJ male MT-RJ female

Indoor, up to 12 Fibers

q q

Yes (Standard) No Cable length L m

q q q q q q

SM 9/125m MM 50/125m MM 50/125m OM3 MM 50/125m OM4 MM 62,5/125m

q q q q q q q q q q q

E-2000 F -3000 FC SC ST MT-RJ male MT-RJ female

q q

Yes (Standard) No

Cord Protection A 0 PC 8 APC Duplex E-2000

Fiber count

Cord Protection B 0 PC 8 APC Duplex E-2000

q q

Connector No Protection

F-3000, SC only Cord Identification A** Color code according to:

q q

Delivered as air ring (Standard max. 100m) Delivered on reel (Standard min. 100m)

q q

DIN/IEC 304

TIA-598-B

Single connector numbered

q q q q q q q

2 4 6 8 12 24

q q

Connector No Protection

F-3000, SC only Cord Identification B ** Color code according to:

q q

DIN/IEC 304

TIA-598-B

Single connector numbered

* Leave section B blank if one side of the assembly will be unterminated. ** Color coding and numbering combinations available upon request.

DIAMOND Fiber Optic Components


CABLE ASSEMBLIES AND ADAPTERS

Fan-Out

SINGLE MODE PC/APC MULTIMODE PC

This solution is recommended where. (Application area) rodent protection is required the trunk cable is longer than 80m preterminated cabling systems are preferred you want to save the costs for splicing and measuring equipment a manufacturer warranty is desired

FEATURES AND BENEFITS


Customer-specific cable length available Fiber types: MM 50 m, MM 62.5 m and SM 9 m Available in a wide assortment of connector styles including: E-2000, F-3000, FC, SC, ST, MT-RJ, .... Armored Cable with Pulling-eye (optional) Color coding for channel identification Forcation made of metall Supplied as air ring or on reel Attenuations test report included

SPECIFICATIONS
Connector: Forcation Housing: Forcation Dimension: - according to IEEE and ITU Standards - Aluminium blue anodizes - 4/6 fibers, outer- 12mm, thread M12 - 12 fibers, outer- 20mm, thread M20 - 24 fibers, outer- 25mm, thread M25 - 48 fibers, outer- 32mm, thread M32 - from 0.5m up to 3m available (other on inquiry) - according color code Swisscom/DIN/IEC/TIA Standard (int.) - optional with channel numbering - optional with protection for connectors or pullin-eye - MM 50m or MM 62.5m - MM 50m OM3 - SM 9m G.652, G.652c, G.652.d, G.652e - SM 9m G.655
MM 50 m 2.7 (850nm) 0.7 (1300nm) MM 62.5 m 3.0 (850nm) 0.7 (1300nm) FORCATION 0.1 (dB) UNITS dB/km

Cord Length: Cord identification: Cord protection: Available fibers:

CABLE TYPE max Insertion Loss (IL)

SM 9 m 0.36 (1310nm) 0.25 (1550nm)

DIAMOND SA Via dei Patrizi 5 CH-6616 Losone - Switzerland Tel. +41 91 785 45 45 Fax +41 91 785 45 00 e-mail info@diamond-fo.com

www.diamond-fo.com

Specifications subject to change without notice


BDD 1900471 07_12

E-2000 Fan-Out

DIAMONDs FAN-OUT cabling system is an easy and secure solution to perform fiber optic installations with no need for expensive tools and equipment. The fan-out trunk cable contains fiber of the customers choice. Each fiber is singularly fanned out, protected by a 2.1mm jacket and factoryterminated with the connectors requested by the customer. The forcation can be used as cable-end fixation and strain relief. For delivery, DIAMONDs FAN-OUT cabling system is well protected in an especially designed packaging, which includes measuring protocols of each channel.

Fan-Out

CABLE SPECIFICATIONS
CABLE Number of Fibers Diameter of Cable Tensile Load Bend Radius Crush Resistance Operating temperature in C * Storage temperature in C * Material INDOOR AND OUTDOOR 12 7.6 24 9.5 36 11.4 48 11.4 12 8.5 OUTDOOR 24 9.0 36 12.0 48 12.0 9000 180 300 EN 60764-1-2E1 EN 60764-1-2E11 EN 60764-1-2E3 TEST CONDITIONS

1000 1000 6000 6000 2500 2500 9000 115 200 140 200 175 300 175 300 130 600 135 600 180 300

Armoring with pulling-eye

-25 +60 -25 +70 FR / LSOH

-40 +60 -40 +70 HDPE

* May be further limited by cable specifications. NOTE Please refer to the connector datasheets for performance specifications.

Connectors protection

ORDER INFORMATION

END A

END B

Cord A LA

Multi-fiber cable L

Cord B LB

END A
Connector type Conn. count max. 48 Pcs. Cord Length L A min. 0.5 m max. 3 m Staggering (40 mm) Cable Cable type

Multi-fiber Cable
Fibers Fiber type

END B*
Connector type Conn. count max. 48 Pcs.

q No. Assembly
Cord Length L B min. 0.5 m max. 3 m Staggering (40 mm)

q q q q q q q q q q q

E-2000 F -3000 FC SC ST MT-RJ male MT-RJ female

q q q

Indoor and outdoor Outdoor

q q

Yes (Standard) No Cable length L m

q q q q q q q q q q q q q q

SM 9/125m MM 50/125m MM 50/125m OM3 MM 50/125m OM4 MM 62.5/125m

Fiber count 2 4 6 8 12 24 48

q q q q q q q q q q q

E-2000 F -3000 FC SC ST MT-RJ male MT-RJ female

q q

Yes (Standard) No

0 PC 8 APC Duplex E-2000,

Cord Protection A

F-3000, SC only

q q q

Connector Pulling-eye No protection

0 PC 8 APC Duplex E-2000,

Cord Protection B

q q

Delivered as air ring (Standard max. 100m) Delivered on reel (Standard min. 100m)

F-3000, SC only

q q q

Connector Pulling-eye No Protection

Cord Identification A** Color code according to:

Cord Identifications B ** Color code according:

q q

DIN/IEC 304

TIA-598-C

Single connector numbered

q q

DIN/IEC 304

TIA-598-C

Single connector numbered

* Leave section B blank if one side of the assembly will be unterminated. ** Color coding and numbering combinations available upon request.