S.No.
IS CODE
1 IS 335 2 IS 694 3 IS 1180 4 IS 1416
IS CODE SPECIFICATION
New Insulating Coils PVC Insulated cables for working voltages up to and including 1100 V (All of 2 Parts) Outdoor type three-Phase distribution transformers up to and including 100 KVA and 11 KV Safety Transformer Specification for pVC insulated(heavy duty) electric cables Part 1 For working up to 1100 KV Part 2 For working voltages from 3.3 KV up to and including 11 KV. (All of 5 parts) Power transformers Specification for fillings and accessories for power transformer. (ALL of 5 parts) Recommended current ratings for cables. (All of 2 parts) Specifications for flexible cables for lift & other flexible connections. Guide for loading of oil immersed transformers. (All of 3 parts) Cross linked polyethylene insulated thermoplastic sheathed cables Part 1 for working voltages up to 7 including 1100V Part 2 For working voltages from 3.3 kV upto 7 including 33 kV Part 3 for working voltages from 66kV up to & including 220kV. Part 1 Elastomer insulated cables for working voltages up to & including 1100 kV. All of 3 parts Code of Practice for selection, installation & maintanance of tranforms Part 1 Selection Part 2 Installation Part 3 Maintance Application guide for power transformers. (All of 64 parts) Methods of test for cables. Specification for dry type transformers. Methods of calculation for maximum external diameter of cables for indoor installation. Part 1 Multicore & symmetrical pair/ quad cables for digital communications part 2 Generic Specification.
5 6 7 8
9 IS 4289 10 IS 6600
11 IS 7078 12 IS 9968
13 14 15 16
17 IS 11892
18 IS 14493
LIGHTING TRANSFORMERS
The lighting transformers shall be 1-phase dry type (AN) for supplying 240V, 1-phase power to DP lighting distribution boards from 415V, 3-phase , 3-wire , 50HZ supply. The units shall be designed, manufactured & tested as per IS 2036 and IS 11171.
(All of 3 parts) Specification for low voltage switchgear & control gear Part 1 Requirements for type tested & partially type tested assemblies Part 2 particular requirements of bulbar trunking system (Busway) Part 3 Particular requirements of equipments where unskilled persons have access for their use. Specification of dry type Tansformers Guide for uniform system of marking & identification of conductors & appratus terminals. (All of 2 Parts) Residual current operated circuit breaker for household & similar uses Part 1 Circuit breakers without integral over current protection (RCCB's) Part 2 breakers with integral over current protection (RCVOs) (all of 4 parts) Low voltage fuses for voltages not exceeding 1000 V AC or 1500 V DC. (All of 5 parts) Specification for low voltages switchgear & control gear assemblies Parts 1 General rule Part 2 Circuit breaker Part 3 switches, disconnectors & combination units Part 4 Contractors & motor starters Part 5 Control circuit devices & switching elements
IS 12640 IS 13703
IS 13947