Professional Documents
Culture Documents
To
All
Table of Contents
Table of Contents / Notation FAQ: I7.5 upgrade and MPC-3
Page
Notation
ok (ok) x ok ok, but newer version recomended not ok not recomended not existing recalled / not in field forbidden / not supported not tested this SW for this component is loaded from PBX In this combinations a newer Sw is loaded from PBX In this combination an older Sw is loaded from PBX Prototype HW
2 3
-> <-1P
Terminals
Corded Terminals: Office 10 / 25 / 34 / 45 Corded Terminals: Aastra 5360 / 5370 / 5380 IP Terminal: Office 35IP IP Terminals: Aastra 5360IP / 5370IP / 5380IP Aastra 2380IP + Miscelaneous Terminals DECT Terminals (Office130/135) DECT Terminals (Office155/160) DECT Systembases (SB4, SB4+, SB8) 15 16 17 18 19 20 21 22
Page 2(1)
Page 2(2)
12)
What is the difference between Office 70IP-b and Office 70IP ? Office70IP-b works as a Office35IP on PBX 5.5 -7.1, has a special "Short User Manual" with less functions and it is shown as Office35IP in AIMS. Office 70IP-b can be reconfigured in AIMS 7.5 Office35IP -> Office70IP and then works as a normal Office 70IP on PBX 7.5, but will need a licence.
13)
Why does my IP-phone not work ? From PBX 7.5 and higher every IP phone needs a licence.
Page 3(1)
Page 3(2)
I5-I6-I7-compatibility-2009-01-19.xls
ok = ok (ok) = ok, but newer version recomended (x) = not recommended x = not ok - = not existing (-) = recalled / not in field
Mainboard A150/A300
System Modules
HW A300/A150
EXP Ascotel A150/A300 7.65 Spain Neris 2 IP / bsica 7.62 Motherboard (MBA) I7 MBA 7.02 (pbx7042f1) MBA 7.10 (pbx7054b1) I71 MBA 7.11 (pbx7056b1) I71 MR1 MBA 7.16 (pbx7058d1) MBA 7.51 (pbx7531c1) I75 MBA 7.52 (pbx7533a1) MBA 7.53 (pbx7536h1)
-1 Beta a) -1 Beta a) -1 Beta a)
DSP-Modules
-1 -1
-1 SM-DSP01 (1 DSP Chip) -1 j) -1A -1P SM-DSP02 (2 DSP Chips) -1 k) -1A
In fabrication
Boot A300/A150
0.07 7.00
SM-LAN8 -1
(ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok)
ok ok ok ok ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok ok ok ok ok
(-) (-) (-) (-) (-) (-) (-) (-) (-) (-) (-) (-) (-) (-)
(-) (-) (-) (-) (-) (-) (-) (-) (-) (-) (-) (-) (-) (-)
ok ok ok ok ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok ok ok ok ok
PBX-Appl.SW
MBA 7.60 (pbx7631f1) I76 MBA 7.61/7.63 (pbx7631i1 / j1) Spain R2R I76 MR1 Spain R2R I76 MR2 I77 MBA 7.62/7.64 (pbx7631s1 / t1) MBA 7.65 (pbx7642g1) MBA 7.66, n642 (pbx7642s1 / n1) MBA 7.67 / 7.68 (pbx7648c1 / g1) MBA 7.71 (pbx7751e1)
a) Beta-version: 9th digit of article.nr. = "0" b) 7.10 only released in France only for A300/A150 c) It is recommended to load newer Sw than 7.51, using SSU d) I76 MR2 supports CLIP on ab-subscriber-ports DSP on MBA: The DSP Chip on MBA supports basic functions and VM 20 Min 2 ports ... and 2 VoIP (free) or 4 DECT or VM 160 Min 2/4 Port (with licence)
Note: With Boot 7.00 on PBX 7.6, 7.7 the coredump must not be used. A Boot version 7.7 will be released for these rare cases.
j) SM-DSP01-1 of prod.date 08.2006 was recalled (wrong assembled) k) SM-DSP02-1 recalled (A300 can't start up) -> Sept 06: DSP02-1A
DSP-Modules: 3 DSP modules can be stacked over each other. Each DSP Chip on the DSP-Modules can be configured for 4 VoIP (with licence) or 8 DECT or VM 160 Min 2/4 Port (with licence)
SM-LAN8: 2 SM-LAN8 can be used The SM-LAN8 is plugged in 2 WA-sockets The SM-LAN8 can be combined with AD2 Cards
depl-0023 / CL 669
Seite 4
I5-I6-I7-compatibility-2009-01-19.xls
Trunk Cards
Analog trunk cards
EAAB2 a) PBX-Appl.SW MBA 7.02 MBA 7.1x MBA 7.5x, 7.6x, n642 MBA 7.67, 7.68 MBA 7.71 -1 TIC-2AB -1P -1 TIC-4AB -1P -1 ESST b) -1 -2
Subscriber Cards
ISDN trunk cards
TIC-2TS -1P -1 TIC-4TS -1P -1 TIC-1PRI -1 -1
Special cards
OAPM -1 ODAB d) NOTST -1 -1
ok ok ok ok ok
ok ok ok ok ok
ok ok ok ok ok
ok ok ok ok ok
ok ok ok ok ok
X X X X X
ok ok ok ok ok
ok ok ok ok ok
ok ok ok ok ok
ok ok ok ok ok
ok ok ok ok ok
X X X X ok
ok ok ok ok e) ok e)
ok ok ok ok e) ok e)
ok ok ok ok e) ok e)
ok ok ok ok ok
ok ok ok ok ok
ok ok ok ok ok
ok ok ok ok ok
ok ok ok ok ok
X X X X X
ok ok ok ok ok
X X X X X
New cards for A150/A300 (Wiring Adapter included) a) on EAAB2 the 2 trunk lines are on port 3,4. details see MBA Wiring Adapters b) ESST HW -1: remote maintenance not ok (few exist in CH, I, E) c) EAD4C, EAD4V not possible in Slot 4. (too long) d) Use ODAB in Slot 2 of A150, or Slot 4 of A300 for full functionality. e) since I76 MR2 CLIP on ab-subscriber-ports supported TIC-2AB with WA-2W (2ab-trunk) TIC-4AB with WA-2W (4ab-trunk) TIC-2TS with WA-TS0 (TT,ST), or order WA-TS1 (SS) TIC-4TS with WA-TS0 (TTTT,STTT), or order WA-TS1 (SSTT,SSST)
A150 supports 2 Slots for Cards A300 supports 4 Slots for Cards
Needed Cards from Ascotel 200 (Wiring Adapter included) ETAB4 is needed for a/b subscribers. (WA-2W is already included) EADP4 is recommended for AD2. (WA-2W is already included)
Each Card needs a Wiring Adapter in the assigned WA-socket. Details see MBA Wiring Adapters
Old Cards from Ascotel 200 (Wiring Adapter not included) EAAB2 ... for new orders TIC-2/4AB shall be used
ESST ... for new orders, TIC-2/4TS shall be used EAD4C works as AD2 only. It is not needed. Courtesy already included on MBA. EAD4V works as AD2 only. It is not needed. VM already included on MBA. OAPM not needed on A150/A300 NOTST not needed on A150/A300.
depl-0023 / CL 669
Seite 5
I5-I6-I7-compatibility-2009-01-19.xls
WA Connector side
TTTT STTT TTTT STTT STTT SSTT SSST SSTT SSST SSTT SSST SSTT 2 Wire 2 Wire 2 Wire 2 Wire 2 Wire 2 Wire 2 Wire WA-1PRI
Port Configuration
TTTT STTT TT ST ST SSTT SSST SS SS SS SS IO & Door/ab 4 * ab 4 * AD2 4 * AD2 4 * AD2 2 * ab trunk 2 * ab trunk 4 * ab trunk T2 - - -
Port x.1
T S T S S S S S S S S IO 1&2 ab AD2 AD2 AD2 ab ab T2
Port x.2
T T T T T S S S S S S IO 3&4 ab AD2 AD2 AD2 ab ab
Port x.3
T T
Port x.4
T T
WA-TS0
T S
T T
WA-TS1
WA-2W
Assigned to AD2-ports on Motherboard no Card inserted EADP4, EAD4C, EAD4V no Card inserted EADP4, EAD4C, EAD4V -
4 * AD2 & LAN c) 4 * LAN 4 * AD2 & LAN c) 4 * LAN 4 * AD2 & LAN c)
AD2 & LAN AD2 & LAN AD2 & LAN AD2 & LAN LAN LAN LAN LAN AD2 & LAN AD2 & LAN AD2 & LAN AD2 & LAN LAN LAN LAN LAN AD2 & LAN AD2 & LAN AD2 & LAN AD2 & LAN
a) Wiring adapter has to be ordered separately (not delivered together with the card) b) System Module SM-LAN8 is plugged in 2 WA-sockets -> It supports 8 LAN-interfaces
c) the RJ45 must be split: - PIN's 1,2,3,6 for the LAN - PIN's 4,5 for AD2
depl-0023 / CL 669
Seite 6
I5-I6-I7-compatibility-2009-01-19.xls
HW 2025/2045 In fabrication
Neris4/8, Spain 7.66 2025/2045 Export 7.67 a) MBS Flash-card & RAM-card 5.0x 5.1x- 5.3x 5.5x- 6.0x -1 -1 -1 1) -2 -2,-3 -2 1) -3(A) -4 -3(A) 1) -5A -5(A) -3(A) 4b) -6 -6 -3A 5b) 5.00 5.10
Boot 2025/2045
5.20 5.40 5.50 6.10 6.20 6.50
Boot 20x5 f)
6.52 6.53 h) 7.50 i)
PBX-Appl.SW 2025/2045
6.1x 6.2x 6.5x - 7.16 7.11+, 7.16+, 7.5x, 7.6x, n642 7.67, 7.68, 7.71 b)
ok X ok X ok ok ok ok ok ok ok 4) ok 4) ok 5),n) ok 5) ok 5),n) ok 5)
X X
X X ok ok 4) ok 5) ok 5)
X X X X X
ok ok 5) ok 5)
X X X X X
X ok ok b)
ok
X X X X X X X
5.00
ok ok ok ok ok
ok ok ok ok ok
ok ok ok ok ok
ok ok ok ok ok
X X X X X
X X X X X
X X X X X
X X X
5.10
X X X
5.20
X X X
5.40
X X X
5.50
X X X
6.10
X X X
6.20
(ok) X X
6.50
ok X X
6.52
ok X X
6.53 h)
X X X X X X
5.0x 5.1x- 5.3x 5.5x- 6.0x 6.1x 6.2x 6.5x - 7.16 7.11+, 7.16+, 7.5x, 7.6x, n642 7.67, 7.68, 7.71 b) Boot / HW MBS-1 with 1) MBS-2 with 1) MBS-3(A) with 1) MBS-3(A) with 4b) MBS-3A with 5b) Boot / Flashcard g) Flashcard-01-2 Flashcard-01-2A Flashcard-02-2 Flashcard-02-2A Flashcard-03-1 Flashcard-03-1A
ok ok
7.50 i)
a) please use SSU, to get newer Sw than delivered from fabrication b) the CLIP on ab-subcriber ports is not supported on MBS. (It needs new HW MBS-4, which is not yet planned) HW-versions of MBS (Motherboard Small) MBS-1: no Rackversion MBS-2: new ISAC + new QSLAC + TI483: system clock exact MBS-3 new SLIC + Flash socket (1 SIM-80 + 1 SO-DIMM144) + Courtesy Flash changed to LV400 needs PBX 6.2* MBS-3A: Including ISDN-Filter on T-port n) MBS-1 incompatible with "some" 128 MB DRAM (20'350'412) If you took an 128 MB SDRAMcard (20'350'412) from a new 7.5 PBX Use the upgradeset 7.5 with the 128 MB SDRAMcard (20'350'579)
X X X X X
5.00
ok X X X X
5.10
ok X X X X
5.20
ok ok X X X
5.40
ok ok X X X
5.50
ok ok X X X
6.10
ok ok ok X X
6.20
ok 4) ok 4) ok 4) ok X
6.50
ok 4) ok 4) ok 4) ok X
6.52
ok 4) ok 4) ok 4) ok X
6.53 h)
ok 5) ok 5) ok 5) ok 5) ok
7.50 i)
ok -
ok -
ok -
ok ok -
ok -
ok ok -
ok ok -
ok ok -
ok ok -
ok ok
Flash-card & RAM-card 1) Included on I5, I6 MBS Flash-01-2 (incl. DL400, MBS-Boot 5.*, 6.*) / RAM 32 MB or Flash-01-2A (incl. LV400, MBS-Boot 5.50, 6.20) / RAM 32 MB 4) Upgrade set I6.5 -I7.1 (contains MBS and MBL SW until 1st Sw update) -1: PBX 6.51, Flash-02-2 (Boot 6.5*) / RAM 64 MB -1A: PBX 6.52, Flash-02-2 (Boot 6.52, 6.53) / RAM 64 MB -1A, aug 07: PBX 6.52, Flash-02-2A (Boot 6.53) / RAM 64 MB ... Spain Upgradeset I6.6: -1: PBX 6.65, Flash-02-2A (Boot 6.53) / RAM 64 MB 4b) Included on I6.5 - I7.1 MBS the same as 4), but only MBS SW 5) Upgrade set I7.5-I7.7 (contains MBS and MBL SW until 1st Sw update) -1: PBX 7.11+, Flash-03-1 (Boot 7.50) / RAM 128 MB -1, july 07: PBX 7.16+, Flash-03-1 (Boot 7.50) / RAM 128 MB (see TI 1218) -1A, aug 07:PBX 7.16+, Flash-03-1A (Boot 7.50) / RAM 128 MB 5b) Included on I7.5/I7.6 MBS the same as 5), but only MBS SW
Boot SW f) the Boot SW >= 6.50 is the same for 2025/2045 and 2065 g) Compatibility between Boot-SW and Flashcard is ensured in fabrication h) Boot 6.53 supports more Flashtypes (jan 2007) i) There is slow and fast Boot 7.5, but the difference is only for MBL 2065.
Note: With Boot 7.5 on PBX 7.6, 7.7 the coredump (d-switch for support cases) must not be used. A Boot version 7.7 will be released for these rare cases.
Licence Chip: (Generations: I5 country -> I6 international -> I65 internat. with new coding) - EIM is automatically converted during a SW upgrade or downgrade - EIM can be moved to another PBX of same or newer generation - EIM can NOT be moved to a PBX of older licence generation - EIM can NOT be moved between MBS and MBL
Please always make an AIMS full backup, even if a SW-upgrade is possible without Firststart or Flash/RAM upgrade: - OK: from "older" I5 PBX SW to "newer" I5 PBX SW - OK: for MBS from I5 (>=5.30) to I6 (>= 6.20) - OK: from I6.5 to I6.6 to I7.1 - OK: from I7.5, I7.6 to I7.7
depl-0023 / CL 669
Seite 7
MBL 2065
ok = ok (x) = not recommended x = not ok - = not existing (-) = recalled
I5-I6-I7-compatibility-2009-01-19.xls
HW 2065 In fabrication
Neris64, Spain 7.66 2065, Export 7.67 a) MBL Flash-card & RAM-card 5.0x -5.20 5.30 / AMI A100 5.5x / 5.6x / AMI A101 6.0*-6.1x 6.2x 6.5x - 7.11 7.11+, 7.16+, 7.5 - 7.71, n642 -1C -1C -1C 2) -2 -2 -2 2) -3(A) -3 -2(A) 3b) -5A -5(A) -2(A) 4b) -2A 5a) -6 -6 -2A 5b) -1/1A
HW MPC-8260
-1B -1C -2 -3 5.10 5.20
Boot 2065
5.30 5.50 6.01 6.10 6.20 6.50 6.52
Boot 20x5 f)
6.53 h) 7.50 slow 7.50 fast
PBX-Appl.SW 2065
ok ok ok ok 3) ok 3) ok 4) ok 5)
ok ok ok 3) (ok) a) ok 3) ok ok 4) ok 4) ok 5) ok 5)
X X X
X X X X X
ok ok
X X X X X
ok ok
X X X X X
X ok
ok ok ok ok ok ok X m)
X X
ok ok ok ok ok
X X
ok ok ok ok ok
X X X X X X
ok
ok ok ok
ok ok ok
ok ok ok
ok ok ok
X X X X
5.10
X X X X
5.20
X X X X
5.30
X X X X
5.50
X X X X X
X X X X X
X X X X X
X X
6.01
X X
6.10
X X
6.20
(ok) X
6.50
ok X
6.52
ok X
6.53 h)
X X X X X X ok
7.50 slow
X X X X X X ok
7.50 fast
5.0x -5.20 5.30 / AMI A100 5.5x / 5.6x / AMI A101 6.0*-6.1x 6.2x 6.5x - 7.11 7.11+, 7.16+, 7.5 - 7.71, n642
a) please use SSU, to get newer Sw than delivered from fabrication HW-versions of MBL (Motherboard Large) MBL-1,1A,1B are the same (except plugged MPC-8260 version) MBL-1C: TI 479: resets if more than 9 SCcards + hand-sol. "5V" MBL-2: "plug for extra-powersupply" ATPS + TI 479: 5V power MBL-2A: New SIM Card connector + Courtesy Flash changed to LV400 needs PBX 6.2* a) MBL-2A needs PBX-SW 6.2* HW-versions of MPC-8260 -1 recalled 6.11.01 (TI 463: Ports on SC-04AB/ SC-08AB blocked) -1A recalled 21.11.01(TI 466: Seldom, remote access via ISDN not possible) -1B solves TI 463 & TI 466 -1C solves TI 483: The system clock on HW-1B is not exact -2 new Sparepart CPU-8255 for performance (see TI 1146) m) MPC-1B is incompatible with 7.5 MPC-1B was delivered until March 03 with SW 5.30 or smaller -> If an MPC-1B with plugged I7.5 Flash & RAM is sent to repair, it will be replaced with MPC-1C, with an invoice for the MPC-Card.
ok ok X
ok ok X
ok ok X
ok ok X
ok ok X
ok ok X
ok ok X
ok ok X
ok ok X
ok ok X
ok ok slow i)
X k) X k) fast i)
5.10
5.20
5.30
5.50
6.01
6.10
6.20
6.50
6.52
6.53 h)
7.50 slow
7.50 fast
Boot / HW MBL-1C with 2) MBL-2 with 2) MBL-2 with 3) MBL-2 with 4b) MBL-2A with 5b) Boot / Flashcard g) Flashcard-01-2 Flashcard-01-2A Flashcard-02-1 Flashcard-02-1A Flashcard-02-2 Flashcard-02-2A Flashcard-03-1 Flashcard-03-1A
ok X X X X
5.10
ok X X X X
5.20
ok ok X X X
5.30
ok ok X X X
5.50
ok 3) ok 3) ok X X
6.01
ok 3) ok 3) ok X X
6.10
ok 3) ok 3) ok X X
6.20
ok 4) ok 4) ok 4) ok 4) ok 4) ok 4) ok ok X X
6.50 6.52
ok 4) ok 4) ok 4) ok X
6.53 h)
ok 5) ok 5) ok 5) ok 5), 5a) X
7.50 slow
ok X -
ok X -
ok X -
ok ok -
ok X -
ok X -
ok ok -
ok ok -
ok ok -
ok ok -
ok ok
ok ok
Flash-card & RAM-card (included in PBX or in Upgradesets) 2) Included on I5 MBL Flash-01-2 (incl. DL400, MBL-Boot 5.*) / RAM 32 MB or Flash-01-2A (incl. LV400, MBL-Boot 5.50) / RAM 32 MB 3) Upgrade Set I6 for MBL (out of production, use directly 4 or 5) Flash-02-1 (incl. DL400, MBL-Boot 6.*) / RAM 64 MB or Flash-02-1A (incl. LV400, MBL-Boot 6.20) / RAM 64 MB 3b) same as 3) but already included on I6 MBL 4) Upgrade set I6.5 -I7.1 (contains MBS and MBL SW until 1st Sw update) -1: PBX 6.51, Flash-02-2 (Boot 6.5*) / RAM 64 MB -1A: PBX 6.52, Flash-02-2 (Boot 6.52, 6.53) / RAM 64 MB -1A, aug 07: PBX 6.52, Flash-02-2A (Boot 6.53) / RAM 64 MB ... Spain Upgradeset I6.6: -1: PBX 6.65, Flash-02-2A (Boot 6.53) / RAM 64 MB 5a) Spain I76 MBL contains MPC-1 and slow Boot 7.50 '- PBX 7.66, Flash-03-1A (Boot 7.50 slow) / RAM 128 MB 5b) Included on I7.5 - I7.7 Export MBL - Export I75-I77 from fabrication is always delivered with MPC-3 -> 5c) 5c) Sparepart MPC-3 -3: MPC-3 and MBL 7.65, Flash-03-1 (Boot 7.50 fast) / RAM 128 MB -3 aug 07: MPC-3 and MBL 7.51, Flash-03-1A (Boot 7.50 fast) / RAM 128 MB Please always make an AIMS full backup, even if a SW-upgrade is possible without Firststart or Flash/RAM upgrade: - OK: from "older" I5 PBX SW to "newer" I5 PBX SW - OK: from I6.5 to I6.6 to I7.1 - OK: from I7.5, I7.6 to I7.7 4b) Included on I6.5 - I7.1 MBL the same as 4), but only MBL-SW 5) Upgrade set I7.5 - I7.7 (contains MBS and MBL SW until 1st Sw update) -1: PBX 7.11+, Flash-03-1 (Boot 7.50 slow) / RAM 128 MB -1, july 07: PBX 7.16+, Flash-03-1 (Boot 7.50 slow) / RAM 128 MB (see TI 1218) -1A, aug 07:PBX 7.16+, Flash-03-1A (Boot 7.50 slow) / RAM 128 MB Boot SW f) the Boot SW >= 6.50 is the same for 2025/2045 and 2065 g) Compatibility between Boot-SW and Flashcard is ensured in fabrication h) Boot 6.53 supports more Flashtypes for Spain production with PBX 6.65 i) There is slow and fast Boot 7.5 (see also FAQ, page 2) k) Protected from overheating: PBX not starting. Note: With Boot 7.5 on PBX 7.6, 7.7 the coredump (d-switch for support cases) must not be used. A Boot version 7.7 will be released for these rare cases.
Licence Chip: - EIM is automatically converted during a SW upgrade or downgrade - EIM can be moved to another PBX of same or newer generation - EIM can NOT be moved to a PBX of older licence generation - EIM can NOT be moved between MBS and MBL
depl-0023 / CL 669
Seite 8
AIMS
ok = ok (ok) = compatible, but newer version recomended (x) = not recomended x = not ok - = not existing ? = not tested
I5-I6-I7-compatibility-2009-01-19.xls
AIMS
PBX-Appl.SW Generation I5 5.10.02, 5.10.01 5.10.03 5.20.03 PBX 5.0x PBX 5.1x PBX 5.20 PBX 5.30 PBX 5.5x / 5.6x PBX 6.00 PBX 6.1* PBX 6.20-6.23 PBX 6.25-6.27 PBX 6.51-6-53 PBX 6.54-6.55 PBX 6.60, 6.62 PBX 6.63, 6.64, 6.66, 6.67 SPAIN PBX 6.65 k) PBX 7.02 PBX 7.10, 7.11, 7.16 PBX 7.51, 7.52, 7.53 PBX 7.60, 7.61, 7.63 SPAIN PBX 7.62 / 7.64 (I76 MR1) PBX 7.65 SPAIN PBX 7.66, n642 (I76 MR2) PBX 7.67, 7.68 PBX 7.71 Generation I6 I6.5 AIN 6.52.01 6.53.00 6.60.21 6.63.01 Spain k) 6.63.05 I7 A300 7.00.13 7.10.05 I75 Aamadeus IP 7.50.11 7.50.12 m) 7.60.10/13 I76 Aamadeus IP + AD2 7.61.02/04a 7.62.03 I77 One number 7.70.12 PBX-Appl.SW
5.30.03
5.50.*
6.00.16
6.10.06
6.20.02
(ok) X X X X X X X X X X X X X X X X X X X X X X
ok ok ok ok ok X X X X X X X X X X X X X X X X X X
ok ok ok ok ok ok ok ok X i) X X X X X X X X X X X X X X
(ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) X X X X X X X X X X X X X
(ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) X X X X X X X X X X X X
(ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) X X X X X X X X X X X
ok ok ok ok ok ok ok ok ok ok ok ok h) ok h) X X X X X X X X X X
ok ok ok ok ok ok ok ok ok ok ok ok ok ok X X X X X X X X X
(ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) (ok) X (ok) X X X X X X X X
ok ok ok ok ok ok ok ok ok ok ok ok ok X ok ok X X X X X X X
? ? ? ? ? ? ? ? ? ? ? (X) (X) X (X) (X) (X) (X) (X) (X) (X) (X) (X)
? ? ? ? ? ? ? ? ? ? ? ok ok X ok ok ok X X X X X X
PBX 5.0x PBX 5.1x PBX 5.20 PBX 5.30 PBX 5.5x / 5.6x PBX 6.00 PBX 6.1* PBX 6.20-6.23 PBX 6.25-6.27 PBX 6.51-6-53 PBX 6.54-6.55 PBX 6.60, 6.62 PBX 6.63, 6.64, 6.66, 6.67 SPAIN PBX 6.65 k) PBX 7.02 PBX 7.10, 7.11, 7.16 PBX 7.51, 7.52, 7.53 PBX 7.60, 7.61, 7.63 SPAIN PBX 7.62 / 7.64 (I76 MR1) PBX 7.65 SPAIN PBX 7.66, n642 (I76 MR2) PBX 7.67, 7.68 PBX 7.71
a) Backups of PBX < 5.50 with AIMS < 5.50 can be loaded to PBX 5.50 with AIMS 5.50 b) Backups of PBX 5.50 with AIMS 5.50 can be loaded to PBX < 5.50 with AIMS < 5.50. i) Some 6.2 PBX can not be configured with any 6.2 AIMS h) PBX 6.6x and AIMS UM 6.6.1.0 and newer: support IP35 on Satellites in Offline mode k) Spanish PBX 6.65 needs AIMS 6.63.05 (late MDT change, RMS 33904 Long SIP Id) AIMS 6.63.05 is compatible to older PBX (eg. Spain PBX 5.50, 5.61, 6.21) k2) A backup of PBX 6.65 in AIMS 6.63.05, can be restored in AIMS 7.61.02 or higher, but is at the same time converted to PBX 7.6. Spain uses AIMS 7.61.04a
m) for SSU please use AIMS 7.50.12 or higher (recommended: AIMS 7.61.02) ...and don't install an older AIMS with SSU on the same PC later (see RI 1214) n) can only be configured with AIMS 7.6 with SQL-DB. There are 2 possibilities: - convert complete DB: AIMS shell: Tools - "Import Paradox DB" (warning: overwrites SQL-DB) - a backup of PBX 7.x in AIMS 7.10.05, can be restored in AIMS 7.61.02 z) many changes because of the "One Number" (new term: subscriber -> user) + new Card TIC-PRI for MBA, new DSP-Combination-builds, .... Windows Vista: - AIMS 7.6 and higher runs on Windows Vista, backward compatible till PBX 7.0x - AIMS 7.50.12 and older can run on Windows Vista in "NT-mode": * Switch off "User Account Control" in the "Security Center" (you need admin rights) * Restart Windows and Install AIMS 7.50.12 or older
For Export countries it is recommended to use: - AIMS 7.10.05 for PBX 5.0 - 7.1 - AIMS 7.70.12 (with SSU) for PBX 7.5- 7.7
depl-0023 / CL 669
Seite 9
OIP
I5-I6-I7-compatibility-2009-01-19.xls
X
6.1.1.3 6.1.2
X
6.1.1.3 6.1.2
X
6.2.0.2 6.2.0.1
X
6.2.0.2 6.2.0.2
X
6.2.0.2 6.2.0.4
Office 1600IP -> 6.1.0.0 OIP-TSP -> Office Suite -> Office eDial -> OIP PBX
6.00 6.10 6.11 6.20-6.23 6.25-6.27 6.51 6.52 - 6.55 6.60,6.62 6.63, 6.64, 6.66, 6.67 Spain 6.65 7.02 7.10, 7.11, 7.16 7.51, 7.52, 7.53 7.60, 7.61, 7.63 Spain 7.62, 7.64, 7.66, n642 7.65, 7.67, 7.68 7.71 X ok ok X X X X X X X X X X X X X X 6.1.0.0
<- Office 1600IP <- OIP-TSP <- Office Suite <- Office eDial OIP PBX
X X
6.1.0.0
X X
6.1.1.3 X X ok X X X X X X X X X X X X X X
X X
6.1.1.7 X X (ok) 1) (ok) 1) X X X X X X X X X X X X X
X X
6.2.0.4 X X (ok) 1) ok 2) ok 2) X X X X X X X X X X X X
X X
6.2.0.6b X X (ok) 1) ok 2) ok 2) X X X X X X X X X X X X
X X
6.2.1.1 X X (ok) 1) ok 2) ok 2) X X X X X X X X X X X X
X X
6.5.0.11 X X (ok) 1) ok 2) ok 2) ok 3) ok 3) X X X X X X X X X X
X X
6.5.2.2 X X (ok) 1) ok 2) ok 2) ok 3) ok 3) X X X X X X X X X X
X X
6.5.2.6 X X (ok) 1) ok 2) ok 2) ok 3) ok 4) X X X X X X X X X X
X X
6.5.3.3 6.5.3.4 X X (ok) 1) ok 2) ok 2) ok 3) ok 4) X X X X X X X X X X
X
1.0.1.0
X
1.0.2.0
X
1.0.4.0
X
1.0.4.0
X
1.0.4.0
X
1.0.5.0
X
1.0.6.0
X
1.0.7.0
X
1.0.8.0
7.7.1.0
X 6.00 X 6.10 not tested 6.11 not tested 6.20-6.23 not tested 6.25-6.27 not tested 6.51 not tested 6.52 - 6.55 not tested 6.60,6.62 not tested 6.63, 6.64, 6.66, 6.67 not tested 6.65 not tested 7.02 not tested 7.10, 7.11, 7.16 not tested 7.51, 7.52, 7.53 ok 7.60, 7.61, 7.63 ok a) Spain 7.62, 7.64, 7.66, n642 ok 7.65, 7.67, 7.68 7.71 ok
1) ACD Applications do not work correctly in this combination 2) Improved ACD Applications & new DAK features (eg. Busy signalling to Call Centers) and Incl. Spanish Language, OEM Splashscreens (needs Saleschannel detection) 3) New I6.5 features / AIN 4) Including Office1560 Serie ! 5) New: Office 1560 with IP, Office 1600IP with AD2 6) Spanish strings only in old generation OIP 6.6.2.0
Windows Vista: - Windows Vista is supported with OIP I7.6 and newer - Generally Applications run on Vista since Project 7.6 OpenCom-PBX: - OIP 7.6.2.3 and higher supports OpenCom-PBX
a) Translations for Spain missing in OIP 7.6 -> Spain wants to deliver them 2009 with OIP 7.7
3rd Party CTI (without OIP): - PBX-SW 5.1*-5.3* needs Ascotel TAPI Driver TSP Version 5.1.0 - PBX-SW 5.5*/5.6* needs Ascotel TAPI Driver TSP Version 5.5.0.1 or higher (newest version 5.5.0.6) - PBX-SW 6.00 needs Ascotel TAPI Driver TSP Version 6.0.0.0 or higher (newest version 6.0.0.2)
1st Party CTI: - AIF-TSP 1.0.0.0 and Office eDial 1.0.2.0 (released together with PBX 6.60) - AIF-TSP 1.0.1.0 and Office eDial 1.0.4.0 (released together with PBX 6.63) - AIF-TSP 1.0.2.0 and Office eDial 1.0.8.0 (compatible with Vista, released together with PBX 7.60) - AIF-TSP 1.0.3.0 and Office eDial 1.0.8.0 (compatible with Vista, released together with PBX 7.65) - AIF-TSP 1.2.0.0 and Office eDial 1.1.0.0 (compatible with Vista, released together with PBX 7.71)
depl-0023 / CL 669
Seite 10
AMI
Ascotel Mobility Interface
I5-I6-I7-compatibility-2009-01-19.xls
MBL-Appl.SW
AIMS
5.20.03 5.30.03
MPC-8260
-1C -2 -3
ISDN -01PRA
-1 -1A
ISDN -02PRA
-1 -1A
MBL 5.0x - 5.6x MBL A100 c) MBL A101 c) MBL 6.0x -7.7x
a) AMI only supported with Ascotel 2065 b) SW A100, A101 supports only AMI (don't use the MBL for other PBX extensions or functions) c) SW A100, A101 are based on MBL SW 5.3* with same compatibility, except A101 supports more MPC-versions d) AMI is supported on newer HW version with SW version 6.0* - 7.5* (see MBL compatibility)
depl-0023 / CL 669
Seite 11
AVS
I5-I6-I7-compatibility-2009-01-19.xls
AVS SW VM Generation I5
5.05 5.12 5.20 5.50 5.52 6.20
VM Generation I6.6
6.65 6.69 6.70
VM-02P, VM-04P
ok
ok
ok
ok
ok
ok
ok ok
ok ok
ok ok
ok = ok (x) = not recommended x = not ok - = not existing ? = net tested orange: Combinations in the field
x
ok ok
x x
ok
x x
ok
x x
ok
x x
ok
x x
ok
AVS Boot
x
ok
x
ok
x
ok
?
ok ok ok
? ?
ok ok
I5
x x (x) (x)
ok ok ok 2) ok 2) ok 2) ok 2) ok 2)
x x (x) (x)
ok ok ok 2) ok 2) ok 2) ok 2) ok 2)
x x (x) (x)
ok ok ok 2) ok 2) ok 2) ok 2) ok 2)
x x (x) (x)
ok ok ok 2) ok 2) ok 2) ok 2) ok 2)
x x (x) (x)
ok 1) ok 1) ok 3) ok 3) ok 3) ok 3) ok 3)
x x (x) (x)
ok 1) ok 1) ok 3) ok 3) ok 3) ok 3) ok 3)
x x (x) (x)
ok 1) ok 1) ok 3) ok 3) ok 3) ok 3) ok 3)
PBX-SW
x x x x x x x
ok ok ok ok ok ok
x x x x x x x
ok ok ok ok ok ok
1) Old functions, old MMI, but new I6.6-limits 2) Old functions old MMI, old limits 3) New functions, new MMI, new I6.6-limits
I6.6
5.05
x
ok ok ok ok ok
I5
x x
ok ok ok ok
x x
ok ok ok ok
x x x
ok ok ok
x x x x
ok ok
x x x x
ok ok
x x x x x
ok
a) VMM 6.60.13 incl. since AIMS 6.60 b) VMM 6.60.17 incl. since AIMS 7.10 and VMM 6.60.16 in AIMS 6.63.05 for Spain
VOX-Files
AVS SW VM Generation I5
5.05 5.12 5.20 5.50 5.52 6.20
VM Generation I5
5.05 ok 5.07 ok 5.08 ok 5.10 ok 6.60.12 ok ok
VM Generation I6.6
6.60.13 ok ok 6.60.16 ok ok ok 6.60.17 ok ok ok
I5
ok
ok
ok
ok
ok
ok
X ok
X ok
X ok ok
I6.6
Vox-Files, Rules
x x
x x
x x
x x
x x
x x
x x
x x
x x
x x
g) ....501.Vox : original Vox-File with 3 languages ....502.Vox: Msg004 "Silence" instead of "please wait" ( BE, DK, CH, PT, SE & Msg007 changed for NL) h) ...660.Vox: original Vox-File for generation I6.6 with 3 languages ...662.Vox: Msg004 & Msg102 "Silence" instead of "please wait" (BE, DK, CH, PT, SE, & Msg007 changed for NL) i) ES_esenca660.vox : Catalan language for Spain needs new AVS version 6.70 ... And VMM 6.60.16 or higher
How to use I6.6 Catalan-Vox-File for I5.50 in Spain: - Get AIMS 6.63.05 according Footnote b) - Use VMM 6.60.16 to load VM 6.70 to the AVS-Card - Use VM 6.60.16 to load the I6.6 Catalan Vox-File => now it works according footnote 1)
depl-0023 / CL 669
Seite 12
Cards
ok = ok (x) = not recommended x = not ok - = not existing
I5-I6-I7-compatibility-2009-01-19.xls
Trunk cards
Analog trunk cards
TC-04AB PBX-Appl.SW HW
Subscriber Cards
ISDN PRA cards
SC-04AB HW -2 -2A e)
Special Cards
Digital subscriber card DSP-Cards
SC-24AD2 HW -32AD2 HW DSP-01 HW DSP-02 HW DSP-04 HW DSPX-02 HW
Option Interface
OI-2DOOR HW
SC-08AD2 HW
SC-16AD2 HW
-1
-1A a)
-1B b)
-1
-1
-1A
-1
-1A
-1
-1A d)
-3 g)
-1
-1A d)
-3 g)
-1
-2 f)
-3 g)
-1
-1A
-1
-1A
-1
-1A
-1
-1A
-1
-1
-1A
-1
-1A
-1
-1
-1
-1A g) PBX-Appl.SW
PBX 5.0x PBX 5.1x-5.3x PBX 5.5x /5.6x PBX 6.0x, 6.1x PBX 6.2x - 6.6x PBX 7.02, 7.11, 7.16 PBX 7.51, 7.52, 7.53 PBX 7.61 - 7.64 PBX 7.65 - 7.66, n642 PBX 7.67, 7.68, 7.71
ok ok ok ok ok ok ok ok ok ok
x
ok ok ok ok ok ok ok ok ok
x x
ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
x x
ok ok ok ok ok ok ok ok
x x
ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
x x
ok ok ok ok ok ok ok ok
x x x x
ok ok ok ok ok ok
x x x x x x x x
ok g) ok h)
ok ok ok ok ok ok ok ok ok ok
x x
ok ok ok ok ok ok ok ok
x x x x
ok ok ok ok ok ok
x x x x x x x x
ok g) ok h)
x x x
ok ok ok ok ok ok ok
x x x x
ok ok ok ok ok ok
x x x x x x x x
ok g) ok h)
ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
x x x
ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
x x
ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok
x x
ok ok ok ok ok ok ok ok
x x x
ok ok ok ok ok ok ok
x x x x x x x
ok ok ok
ok ok ok ok ok ok ok ok ok ok
x x
ok ok ok ok ok ok ok ok
PBX 5.0x PBX 5.1x-5.3x PBX 5.5x /5.6x PBX 6.0x, 6.1x PBX 6.2x - 6.6x PBX 7.02, 7.11, 7.16 PBX 7.51, 7.52, 7.53 PBX 7.61 - 7.64 PBX 7.65 - 7.66, n642 PBX 7.67, 7.68, 7.71
a) TC-04AB-1A: removed components for dialtone detection dialtone detection ist done by SW (SW 5.10 and higher) b) TC-04AB-1B: new QSLAC (NFI5-014) c) ISDN-04/08ST-2,-2A: new ISAC (NFI5-014) ISDN-04/08ST-2B -> ISDN-Filter on T-port
d) SC-04/08AB-1A: new QSLAC & old SLIC (NFI5-014) e) SC-04/08AB-2: old QSLAC & new SLIC (less old SLIC available, than old QSLAC) SC-04/08AB-2A: new QSLAC & new SLIC (final solution) f) SC-16AB-2: new QSLAC & new SLIC (final solution) g) -3 new SLIC supported since I76 MR1 (7.65) h) new SLIC supports CLIP for ab-subscr. since I76 MR2 (7.67)
DSPX-02 - more VoIP channels per DSP or FAX over IP T.38 - also supports DECT, VM, GSM (same as the other DSP cards).
depl-0023 / CL 669
Seite 13
AIP Cards
I5-I6-I7-compatibility-2009-01-19.xls
AIP Cards
AIP 6400 / 6350 / 6500 (IP-Card: IPI-100BT)
AIP 6400 C)
DRS-04/08 HW PBX-Appl.SW PBX 5.0x PBX 5.10 PBX 5.11 PBX 5.20 PBX 5.30 5.5x/5.6x PBX 6.0* PBX 6.1* PBX 6.2* PBX 6.51 6.52,6.53 PBX b567 6.54,6.55 6.60, 6.62, b655 6.63-6.67 7.02 7.11, 7.16 7.51, 7.52, 7.53 7.61-7.66 7.67, 7.68, n642, 7.71 SW IP-IPI HW
-1 ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok
-2 ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok
- 2A ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok
2.02 ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok
5.50 ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok
5.52 ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok
-1 ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok
- 1 e)
-2
- 2A
5.50
6.50.1
6.52.1
6.52.2
6.54.0
6.60.5
6.63.0
7.0.1
7.1.1
7.6.0
7.7.1
x
X X X X X X X X X X X X X X
ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok
ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok
x x x x x
ok ok ok ok
A) -> A) -> A) -> A) -> D) X D) X D) X D) X D) X D) X D) X
x x x x x x x x x
PBX
B) -> B) -> B) ->
x x x x x x x x x
<- B)
x x x x x x x x x
<- B) <- B)
x x x x x x x x x
<- B) <- B) <- B)
x x x x x x x x x
<<<<PBX -> -> -> -> -> ->
x x x x x x x x x
<<<<<PBX -> -> -> -> ->
x x x x x x x x x
<<<<<<PBX -> -> -> ->
x x x x x x x x x
<<<<<<<PBX PBX -> ->
x x x x x x x x x
<<<<<<<<<PBX ->
x x x x x x x x x
<<<<<<<<<<PBX
PBX
B) -> B) ->
PBX
B) ->
e) The codec G.729 is not fully supported in this combinartion. (TI 519) Don't use DRS 4/8-1 and DRS4/8-2* on the same card !!!
This AIP SW included in this PBX-SW-package The compatible AIP SW is loaded, if either ... - the SW-package is loaded with the Upload Manager - the PBX is restarted AIP6350 becomes AIP6500 by SW update ! in I6.5 the AIP6500 SW can also be loaded with the Reset-button on the AIP6500 AIP6400 can be changed to AIP6500 (TI 999) AIP6350 must be updated by hand or on I6.5 (TI 999)
A) B) C) D)
depl-0023 / CL 669
Seite 14
Corded Terminals
ok = ok (X) = not recommended X = not ok - = not existing V = forbidden
I5-I6-I7-compatibility-2009-01-19.xls
Office 10,20,30,40
HW
Office 25
HW HW
Office 35
SW HW
Office 45 / 45pro
Boot-SW Appl-SW
EKP
SW
AKB
SW
PBX-Appl.SW
PBX I4 / I4net PBX 5.0* -5.3* PBX 5.5* / 5.6* PBX 6.0* - 6.2* 6.5*, 6.6* 7.02 - 7.16 7.51 - 7.53 7.6x, n642, 7.71
-1* ok a) ok ok ok ok ok ok ok
-1 X ok ok ok ok ok ok ok
-1A X ok ok ok ok ok ok ok
-1A ok ok ok ok ok ok ok ok
-1B -1C ok ok ok ok ok ok ok ok
-2 d) ok ok ok ok ok ok ok ok
1.00 (1.10) X ok ok ok ok ok ok ok
1.30 X X X X X X X X
1.60 ok b) ok ok ok ok ok ok ok
-1 X ok ok ok ok ok ok ok
-1A X ok ok ok ok ok ok ok
-1B X ok ok ok ok ok ok ok
-2 d) X ok ok ok ok ok ok ok
1.20 X ok ok ok ok ok ok ok
1.20 X ok ok ok ok ok ok ok
1.22 X ok ok ok ok ok ok ok
1.23 X ok ok ok ok ok ok ok
1.00 X c) ok ok ok ok ok ok ok
1.40 ok b) ok ok ok ok ok ok ok
1.00 X ok ok ok ok ok ok ok
a) Office10 works with >= 4.65. Office 20, 30,40 works since 4.0* b) Office 35 1.60 and EKP 1.40 work on I4 / I4net ... except in Italy Freemarket, where it only works since PBX 4.75 (ARTE-Bit) c) Don't use EKP 1.00 on I4 /I4net. It causes PBX Resets ! ... Since Aug 2004 only EKP 1.40 is produced and delivered d) New HW -2 because "end of life" of a IC-Component (TI 1216)
Office 35 SW: 1.00 in fabric., until July 04 (Spain-Label, 1.10) 1.30 recalled (RMS 30275, 22476: Office35 resets) 1.60 in fabric. since July 04 (also for Spain)
Office 45 Boot SW 1.00 in fabric. from Mai 01 - Oct 01 1.10 recalled (TI 464) Can't load Office45 Appl-SW 1.20: in fabric. since Nov.01 Office 45 Appl SW (loaded from PBX) 1.00 loaded from PBX 5.00 (not recommended) 1.10 loaded from PBX 5.1* (not recommended) 1.20 loaded from PBX 5.20 (1.20 in fabric. loaded from Nov. 2001) 1.22 loaded from PBX 5.50 1.23 loaded from PBX 6.10
depl-0023 / CL 669
Seite 15
I5-I6-I7-compatibility-2009-01-19.xls
Office 60
HW Terminal-Boot Terminal -Sw.
Aastra 5360
-2 X X X ok ok ok ok 2.6.14.1 2.6.15.1 X X X -> -> -> ->
Office 70 / 80
-1 2.6.14.1 2.6.18.1 X X X PBX -> -> -> 2.6.14.1 j) 2.6.18.2 j) X X X <PBX -> -> 2.12.4.2 2.6.19.1 X X X <<PBX ->
-1 X X X ok ok ok ok
PBX 5.0* -5.3* PBX 5.5* - 7.1* PBX-Appl-SW 7.5x 7.60 7.61- 7.64 7.65, -7.68, n642 7.71
(PBX), (->) = M530-SW loaded from PBX, only if power supply on AD2 resp. on IP Phone z) state in fabrication
Office Terminals -> Aastra Terminals: - There is no effect on the compatibility, it's only a renaming. - The Hw-version -2 is only an improvement with no effect on the compatibility. - From Feb 2009 only Aastra Terminals are delivered. (except Spain) Aastra Terminals on Nexspan: - Aastra Terminals are prepared and in test to work on Nexspan PBX
depl-0023 / CL 669
Seite 16
Office 35IP
ok = ok (X) = not recommended X = not ok - = not existing PBX = this Sw is loaded from PBX ? = not tested
I5-I6-I7-compatibility-2009-01-19.xls
Office 35IP
HW Boot SW Boot SW SW SW SW SW SW SW SW SW
-2 PBX 5.0x -5.3x PBX 5.5x / 5.6x PBX 6.0x -6.2x PBX 6.5* PBX b567 PBX 6.54,6.55 6.60, 6.62 b655 6.63-6.67, 7.02 7.1x-7.6x, 7.71 X ok ok ok ok ok ok ok ok ok
-2A h) X ok ok ok ok ok ok ok ok ok
1.0.0
5.5.0 (1.0.7) X ok ok
2.0.0 X ok ok ok ok ok ok ok ok ok
d) PBX I6.5 needs Office35IP (Boot 2.0.0 and SW >= 1.4.5) e) How to upgrade Office 35IP Boot 2.0.0 -> TI 953 f) PBX >= 6.5 loads newer SW into Office 35IP, only if Boot is 2.0.0 - IP35 1.6.0 and higher supports IP35 assigned to Satellite in Offline Mode - IP35 HW -2A supports Power over Ethernet "PoE 802.3af", details see TI 971
depl-0023 / CL 669
Seite 17
I5-I6-I7-compatibility-2009-01-19.xls
Each Aastra 5360IP, 5370IP 5380IP (Office 60IP / 70IP / 80IP) needs a licence except when used as Office 35IP with SW 1.x.x
Aastra M535
IP Phone licence
License needed
-1/-1A
HW
-2
-2
d)
1.1.1 2.2.4 X X (X) -> -> -> -> -> -> ->
Terminal -SW
5.0x -5.3x 5.5x - 7.1x 7.51 7.52 PBX-Appl-SW 7.53 7.60 -7.64 7.65, 7.66 Spain n642 7.67, 7.68 7.71
h) Aastra 5370IP/Office70IP with Sw 1.x.x (70IP-b) can be registered in AIMS as : - Office 35IP. Then it needs no license. (KBM/DKBM is not supported) - Aastra 5370IP/Office 70IP it receives new SW (from PBX) and requires a license i) Downgrade of Aastra 5370 IP (HW-2) to SW 1.x.x (70IP-b) is possible, Tool see RI 1159 or "IP Uploadmanager" available on DL server HW-version (details) -1 Export was used only for the deliveries 70IP-b -1A (Export) was used with the new deliveries 70IP -1 (Spain-OEM) is the same as -1A Export -1A (Spain-OEM) additional OEM-requirement -2 (Export) more RAM + Aastra-terminal names
g) Office 60IP, 70IP, 80IP (HW -1/1A, Sw 1.x.x) were delivered until Nov 2008. Office70IP could be used directly as 70IP-b - h) Office60IP/ 80IP always directly received newer SW k) Since Nov 2008 only Aastra 5360IP, 5370IP, 5380IP are delivered. They contain more RAM (Hw -2) and SW 2.x.x and new Boot-loader 1.0.6
Aastra Terminals on Nexspan: - Aastra IP terminals with SW 2.10.20 or higher work on Nexspan PBX - Aastra 5380IP exists also with Azerty Keyboard
depl-0023 / CL 669
Seite 18
I5-I6-I7-compatibility-2009-01-19.xls
Office 100
Office 150
PRISA-1
Pocket-Adapter
PRISA-2 Exp, -2A Exp, -2B Es, -2A
PC Operator Office1550 f)
SW
SW
SW
SW
HW-2A
PBX 5.0* -5.6* PBX 6.0* PBX 6.1* - 6.55 6.60, 6.67 7.02 - 7.16 7.5x -7.64 (I76 MR1) 7.65, 7.66, n642 (I76 MR2) 7.67,7.68 7.71
1.0.0.0 X X X X X X (ok) y) ok X z)
1.509.0.0 X X X X X X X z) X z) ok
1.1* (X) (X) (X) (X) (X) (X) (X) (X) (X)
1.2* a) ok ok ok d) ok d) ok d) ok d) ok d) ok d) ok d)
<1.32 b) V V V V V V V V V
1.32 c) (X) (X) (X) (X) (X) (X) (X) (X) (X)
1.33 ok ok ok d) ok d) ok d) ok d) ok d) ok d) ok d)
1.34 ok ok ok d) ok d) ok d) ok d) ok d) ok d) ok d)
< 2.4 X X X X X X X X X
2.4 ok ok ok ok ok ok ok ok ok
2.5 (ok), (ok), (ok), (ok), (ok), (ok), (ok), (ok), (ok), e) e) e) e) e) e) e) e) e)
2.6 ok ok ok ok ok ok ok ok ok
2.5
ok ok ok ok g) ok g) X X X X
z) WARNING: Aastra 2380IP is not forward or backward compatible. And it must be loaded manually. y) Aastra 2380IP in I76 MR1 is ok, but newer generation recommended because of restrictions and bugs: - no Trial license - expansion-modul key-label allows only 14 digits (not 20) - not possible to dial canonical number format (+43 ...) .
a) Office100: SW 1.20 or higher is recommended to avoid old problems b) Office150: SW <1.32 called back from the field, with no exception !! c) Office150: SW 1.32 is only allowed in Spain ! d) For Office100/150 on PBX 6.1-6.5 set "Compatibility Mode"= "Old Mode", see AIMS CM 1-3-1-1 "Cordless-DECT- Sys.param." In "Old Mode" only 6 lines used on SB8, Default setting is "New Mode" Pocket Adapter: e) ECO 20214 (march 06) - Export -2A / SW 2.5 is not ok on AD2 cables longer than 400m - Spain -2A / SW 2.5 has no problem (it is the same as Export -2B / 2.6) PC Operator, Office1550: f) Follow-up product see Office1560 in OIP g) Dataloader" for Office 1550 configuration, see DL-server h) Office1550 is no more supported since 7.5
depl-0023 / CL 669
Seite 19
DECT-130-135
Air SW Download:
"PBX" "ok" "->" "<-" this DECT-SW is incl. in the PBX-SW this DECT-SW is unchanged (when registered on PBX) newer DECT-SW is loaded (when registered on PBX, System "A") older DECT-SW is loaded (when registered on PBX, System "A")
I5-I6-I7-compatibility-2009-01-19.xls
Compatibility:
Everything is compatible with few restrictions: "130" Office135 works only as 130 (and keeps the SW, see c) ) Compatibility with I4/I4net, see CL 992
"SW Category": protection from older SW "Lab.version": Internal version, twice Longklick 5
Office 130 a)
SW Category 0 00.53.00 0 00.57.00 0 00.58.00 0 00.61.00 0 00.62.00 0 00.68.00 0 00.70.00 1 60.81.00 1 60.89.00 2 60.95.00 2 61.01.00 3 61.08.00 4 61.09.00 / ES 61.10.00 4 61.16.00 5 61.20.00
Lab.version
DECT PBX
5.0x 5.10 a) 5.11 5.20 5.30 5.50 5.52 5.55 5.61 5.63 5.64 6.00 6.10 b) 6.11 6.20 6.21 6.23 6.25-6,27 6.51 6.52, 6.53 6.54,6.55 6.60, 6.62 6.63 - 6.67 7.02, 7.10 7.11, 7.16, 7.5x 7.6x, n642, 7.71
2.00
2.10
2.11
2.12
2.13
2.14
2.15
2.21
2.30
2.40
3.00
3.01
3.02 / ES3.00
3.03
3.05
3.06
3.07
3.08
3.09
3.10
3.11
3.12
61.38.00
ok -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok PBX PBX -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok <<PBX -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok <<<PBX -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok <<<<-> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok <<<<-> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok <<<<PBX PBX -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok ok ok ok ok ok ok PBX -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok ok ok ok ok ok ok <-> -> -> PBX -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok ok ok ok ok ok ok ok PBX -> -> ok -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 <-, 130 ->, 130 ->, 130 ok, 130 PBX -> -> -> -> -> -> -> -> -> -> -> -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 PBX, 130 ->, 130 ok, 130 ok PBX -> -> -> -> -> -> -> -> -> -> -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ->, 130 ok, 130 ok ok -> -> -> -> -> -> -> -> -> -> -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ->, 130 ok, 130 ok ok PBX -> -> -> -> -> -> -> -> -> -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 PBX, 130 ok, 130 ok ok ok PBX PBX -> -> -> -> -> -> -> -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok ok ok ok ok -> -> -> -> -> -> -> -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok ok ok ok ok -> PBX -> -> -> -> -> -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok ok ok ok ok -> <PBX -> -> -> -> -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok ok ok ok ok PBX ok ok PBX -> -> -> -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok ok ok ok ok ok ok ok ok PBX -> -> -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok ok ok ok ok ok ok ok ok <PBX PBX -> ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok ok ok ok ok ok ok ok ok <<<PBX ->
ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok ok ok ok ok ok ok ok ok <<<<PBX
a) Office130 Air SW download, since PBX 5.10 b) Office135 Air SW download, since PBX 6.10
depl-0023 / CL 669
Seite 20
DECT-155-160
Air SW Download:
"PBX" "ok" "->" "<-" this DECT-SW is incl. in the PBX-SW this DECT-SW is unchanged (when registered on PBX) newer DECT-SW is loaded (when registered on PBX, System "A") older DECT-SW is loaded (when registered on PBX, System "A") Office160 can replace Office155 also on I4 see CL992
I5-I6-I7-compatibility-2009-01-19.xls
"SW Category": protection from older SW "Lab.version": Internal version, twice Longklick 5
Office155
Lab.version
DECT PBX
5.0x 5.50 a) -5.55 5.61 5.63 5.64 6.00 6.1x 6.20 6.21 6.23 6.25-6.27 6.51 6.52-6.55 6.60 -6.67 7.02 7.1x 7.5x 7.61-7.67, n642 7.68, 7.71
1.00
1.01
1.02
1.03
1.10
1.11
1.12
1.13
1.15
1.16
1.17
1.18
1.01
1.03 z)
1.10
1.12
1.13
1.14
1.16
ok -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> ->
ok PBX a) -> -> -> PBX -> -> -> -> -> -> -> -> -> -> -> -> ->
ok ok -> -> -> ok -> -> -> -> -> -> -> -> -> -> -> -> ->
ok ok PBX -> -> ok -> -> -> -> -> -> -> -> -> -> -> -> ->
ok ok ok PBX -> ok PBX -> -> -> -> -> -> -> -> -> -> -> ->
ok ok ok ok -> ok <PBX -> -> -> -> -> -> -> -> -> -> ->
ok ok ok ok PBX ok ok ok PBX -> -> -> -> -> -> -> -> -> ->
ok ok ok ok ok ok ok ok ok PBX -> -> -> -> -> -> -> -> ->
as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 PBX y) -> -> -> -> ->
as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 ok PBX -> -> -> ->
as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 ok ok PBX -> -> ->
as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 ok ok ok PBX -> ->
as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 ok ok ok ok PBX ->
as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 ok ok ok ok ok PBX
as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 as 130 ok ok ok ok ok ok
"as130": Office160 can be announced as Office130 (with 15 digits) y) Office160 Air Sw Download works since PBX I7.0 z) since July 06 Sw 1.03 is delivered from fabrication.
HW-version -2: (fabrication ~ feb 2009) The display component had to be exchanged. HW -2 is supported with SW 1.16 1.16 is protected from downgrade
depl-0023 / CL 669
Seite 21
DECT-Systembases
SW Download:
"PBX" "ok" "->" "<-" this DECT-SW is incl. in the PBX-SW this DECT-SW is unchanged (when registered on PBX) newer DECT-SW is loaded (when registered on PBX, System "A") older DECT-SW is loaded (when registered on PBX, System "A")
I5-I6-I7-compatibility-2009-01-19.xls
"SW Category": protection from older SW "Lab.version": Internal version, twice Longklick 5
SB4
SW Category 0 00.42.00 0 01.05.00 0 01.06.00
SB4+ , SB8 b)
1 01.07.00 1 01.11.00 1 01.12.00 2 01.14.02 2 01.15.00
Lab.version
DECT PBX
5.0x-5.30 5.50-5.52 5.55 5.61-5.64 6.00-6.11 6.20 b) -6.23 6.25-6.27 6.51 6.52-6.55 6.60, 6.62 6.63 - 6.67 7.02 7.10, 7.11 7.16 7.5x 7.61-7.66, n642 7.67, 7.68, 7.71
1.00 f)
1.05
1.06
1.07 h)
1.11
1.12
1.14.02
1.15
a) SB 1.14.02 contains a change that is not compatible with old PBX-Versions (RMS 36065). It is rare, because the fabric. delivers 1.07. The problem is corrected with 1.15.
00.57.6E 00.63.6E 00.64.6E 00.72.6E 00.72.6E 00.75.6E 00.77.6E 00.76.6E 00.77.6E 00.77.6E 00.77.6E 00.77.6E 00.77.6E 00.77.6E 00.77.6E 00.77.6E 00.77.6E
(X) (X) (X) (X) (X) (X) f) -> -> -> -> -> -> -> -> -> -> ->
SB4 SB4 SB4 SB4 SB4 <- g) -> PBX -> -> -> -> -> -> -> -> ->
SB4 SB4 SB4 SB4 SB4 <- g) PBX <PBX -> -> -> -> -> -> -> ->
SB4 SB4 SB4 SB4 SB4 ok h) ok ok ok PBX -> -> -> -> -> -> ->
SB4 SB4 SB4 SB4 SB4 ok h) ok ok ok <PBX -> -> -> -> -> ->
SB4 SB4 SB4 SB4 SB4 ok h) ok ok ok <<PBX PBX -> PBX -> ->
Xa) Xa) Xa) Xa) Xa) Xa) Xa) ok ok ok ok ok ok PBX ok PBX ->
f) SB-SW 1.00 is not recommended (was only used in FT) g) upgrade PBX >= 6.25 to avoid SB-SW 1.00 h) protected 1.07 (in prod. since july 05) -> no problem for Spain with PBX 6.21
depl-0023 / CL 669
Seite 22