Level Point Level / Liquids 16.01.2013 03:54 PM

Liquipoint T FTW32

Liquipoint T FTW31

One rod probe 11961Z

Measuring principle Characteristic / Application

Conductive Compact rope probe with multi point detection possible up to 5 switch points. Simple rope shortening possible DC PNP 10,8V ... 45V Relay 20V ... 230V AC Relay 20V ... 55V DC -40 C ... 70 C (-40 F ... 158 F) -40 C ... 70 C (-40 F ... 158 F) Vacuum ... 10 bar (Vacuum ... 145 psi) 10 S/cm 316L, FEP, PPS 500 N G 1 1/2 NPT1 1/2" 0.25m ... 15m (10" ... 590") DC PNP Relay ATEX WHG/ Overfill prevention Leakage Detection Certificate Observe min. medium conductivity Compact Separate Transmitter: FTW325

Conductive Compact rod probe with multipoint detection, possible up to 5 switch points. Simple rod shortening. DC PNP 10,8V ... 45V Relay 20V ... 230V AC Relay 20V ... 55V DC -40 C ... 70 C (-40 F ... 158 F) -40 C ... 100 C (-40 F ... 212 F) Vacuum ... 10 bar (Vacuum ... 145 psi) 10 S/cm 316L, PP, PPS 1000 N G 1 1/2 NPT1 1/2" 0.1m ... 4m (3.9" ... 157") DC PNP Relay ATEX WHG/ Overfill prevention Leakage Detection Certificate Observe min. medium conductivity Compact Separate Transmitter: FTW325

Conductive One rod probe for high and extremely low temperature and high pressure. Corrosion resistant Relay PFM -200 C ... 250 C (-328 F ... 482 F) -200 C ... 250 C (-328 F ... 482 F) Vacuum ... 160 bar (Vacuum ... 2320 psi) 20 S/cm Ceramic, 316TI G 1/2

Supply / Communication

Ambient temperature Process temperature Process pressure absolute / max. overpressure limit Min. conductivity of medium Main wetted parts Max. tensile strength Process connection Process connection hygienic Sensor length Output Certificates / Approvals

0.1m ... 2m (3.9" ... 79") Relay ATEX WHG/ Overfill prevention

Specialities Application limits Instrumentation Electronic insert Components Observe min. medium conductivity Separate PFM: EC17Z, EC27Z Transmitter: FTW325

1/3

Product Comparison
Level Point Level / Liquids 16.01.2013 03:54 PM

One rod probe 11375Z

Triple rod probe 11363Z

Double rod probe 11362Z

Measuring principle Characteristic / Application

Conductive One rod probe for high temperature and high pressure. corrosion resistant Relay -40 C ... 80 C (-40 F ... 176 F) -40 C ... 135 C (-40 F ... 275 F) Vacuum ... 50 bar (Vacuum ... 725 psi) 20 S/cm PTFE, 316TI

Conductive Triple rod probe with high-class media contacting wetted parts Relay -20 C ... 80 C (-4 F ... 176 F) -40 C ... 150 C (-40 F ... 302 F) Vacuum ... 30 bar (Vacuum ... 435 psi) 20 S/cm PTFE, PFA, 316 TI, Alloy B/C4, Titan, Tantal, Monel G 1 1/2A NPT1 1/2" Flange DIN /ANSI 0.1m ... 4m (4" ... 157") Relay ATEX WHG/ Overfill prevention

Conductive Double rod probe with high-class media contacting wetted parts Relay -20 C ... 80 C (-4 F ... 176 F) -40 C ... 150 C (-40 F ... 302 F) Vacuum ... 30 bar (Vacuum ... 435 psi) 20 S/cm PTFE, PFA, 316 TI, Alloy B/C4, Titan, Tantal, Monel G 1 1/2A NPT1 1/2" Flange DIN /ANSI 0.1m ... 4m (4ft ... 157ft) Relay ATEX WHG/ Overfill prevention Observe min medium conductivity Separate Transmitter: FTW325

Supply / Communication Ambient temperature Process temperature Process pressure absolute / max. overpressure limit Min. conductivity of medium Main wetted parts Max. tensile strength Process connection

G 1 1/2

Process connection hygienic Sensor length Output Certificates / Approvals Specialities Application limits Instrumentation Electronic insert Components Transmitter: FTW325 Transmitter: FTW325 observe min. medium conductivity Observe min. medium conductivity seperate Seperate 0.05m ... 2m (2" ... 79") Relay ATEX WHG/ Overfill prevention

2/3

Product Comparison
Level Point Level / Liquids 16.01.2013 03:54 PM

One rod probe 11371

Pump Protection FTW360

Liquipoint FTW33

Measuring principle Characteristic / Application

Conductive One rod probe. Simple rod shortening or rod change on location

Conductive Compact limit switch for pump protection, Active build up compensation, Flush mounting

Conductive Compact point level switch for using in pipes and in storage, mixing and process vessels with or without an agitator, Active build up compensation, Flush mounting 1030 V DC -40 ... 70C -40 ... 158F Standard: -20 ... 100C Cleaning: -20 ... 150C for 1h -4 ... 302F for 1h 0 ... 25 bar abs 0 ....362,5 psi abs 1S/cm Sensor: 316L Sensor isolation: PEEK Thread G1, G1/2, G3/4, M24 Clamp ISO 2852 1 to 1 1/2", 2", DIN11851 Pipe union

Supply / Communication Ambient temperature Process temperature

Relay -20 C ... 120 C (-4 F ... 248 F) -20 C ... 120 C (-4 F ... 248 F)

21V ... 253V AC 20V ... 200V DC -20 C ... 60 C (-4 F ... 140 F) -20 C ... 100 C (-4 F ... 212 F)

Process pressure absolute / max. overpressure limit Min. conductivity of medium Main wetted parts Max. tensile strength Process connection Process connection hygienic Sensor length Output Certificates / Approvals Specialities Application limits Instrumentation Electronic insert Components

Vacuum ... 10 bar (Vacuum ... 145 psi) 20 S/cm PFA, 316TI

Vacuum ... 10 bar (Vacuum ... 145 psi) 10 S/cm 1.4571, PTFE

G 1 1/2A Einschweistutzen

G3/4

0.05m ... 2m (2" ... 79") Relay Relay DC PNP EHEDG 3A CIP suiteable Observe min. medium conductivity Seperate Transmitter: FTW325 Observe minimum medium conductivity CIP and SIP suiteable Conductive foam is recognizes as a liquid Compact DC PNP

3/3