Analog/ISDN/GeoCENTREX General Facility Reset (GFR)


A30828-X1150-B637-1-7629

General Facility Reset (GFR)

Information Analog/ISDN/GeoCENTREX

Trademarks: All designations used in this document can be trademarks, the use of which by third parties for their own purposes could violate the rights of their owners.

Copyright (C) Siemens AG 2000


Issued by the Information and Communication Networks Group Hofmannstrae 51 D-81359 Mnchen Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

A30828-X1150-B637-1-7629

Information Analog/ISDN/GeoCENTREX

General Facility Reset (GFR)

This document consists of a total of 12 pages. All pages are issue 1.

Contents
1 2 3 3.1 3.2 3.3 3.3.1 3.3.2 3.4 3.5 4 5 6 Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Mode of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Subscriber controlled input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Analog. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISDN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GeoCENTREX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Analog. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISDN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Additional possibilities for feature control . . . . . . . . . . . . . . . . . . . . . . . . . . . Legend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 8 8 9 9 9 9 9

Call charge registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

A30828-X1150-B637-1-7629

General Facility Reset (GFR)

Information Analog/ISDN/GeoCENTREX

A30828-X1150-B637-1-7629

Information Analog/ISDN/GeoCENTREX

General Facility Reset (GFR)

1 Denition
The feature General Facility Reset (GFR) allows the subscriber to reset different features, which are currently active, with just one controlled input. Subscriber data related to features, such as the forwarding number in case of call forwarding, will not be deleted.

Network node GFR

STOP

CW CFW CLIR

Operator benefits increased control over all other subscriber features Subscriber benefits more user-friendly implementation of the features increased control over all other subscriber features and reduction in administrative effort Availability Analog Subscriber GeoCENTREX subscriber Use and effect Calling subscriber GFR use GFR effect Interactions For interaction with other features, see Feature Interactions. X X Called subscriber X X X X ISDN X X

A30828-X1150-B637-1-7629

General Facility Reset (GFR)

Information Analog/ISDN/GeoCENTREX

2 Mode of operation
The feature General Facility Reset (GFR) can be used to deactivate all features marked with GFR in the network node. The subscriber can deactivate all of his or her features that are currently active with just one input. Two variants are provided: General facility reset including alarm calls General facility reset excluding alarm calls. The operator can determine whether the first or second variant is to be made available at network node level. When GFR has been successful, the user can receive the same tone or announcement received as when he or she deactivates a single feature, or a more specific tone or announcement. If the subscriber has several numbers (MSN) and/or several services (ISDN), the user can activate features for one or more numbers and/or one or more services. In this case, General Facility Reset will be performed for the numbers and services for which features are active. Facilities with PIN Depending on whether a subscribers features were activated in combination with a keyword or not, GFR must likewise be entered with or without a keyword. Entry of GFR without a keyword only deactivates features that were likewise activated without a keyword. Facilities that can be deactivated All features administrable by the subscriber by SCI, except call related inputs, are subject to GFR. For features with data which can be administrated (e.g. a destination directory number in call forwarding cases) and separate activation, only the activation is reset. It is possible to specify whether the subscriber features have to be reset with GFR or not. The alarm call services, casual, periodic and specific, are treated as one feature and reset with the GFR variant including alarm call service, regardless of which one is active.

3 Subscriber controlled input


The feature can be used by subscriber controlled input. For the subscriber procedure, see: Analog subscriber ISDN subscriber GeoCENTREX Analog subscriber ISDN subscriber

A30828-X1150-B637-1-7629

Information Analog/ISDN/GeoCENTREX

General Facility Reset (GFR)

Subscriber controlled input functions

Signaling method Analog Pulse DTMF --X ------------------ISDN Keypad --X ------------------Funct. -----------------------

Activate Deactivate Enter data Delete data Enter data and activate Delete data and deactivate Activate with/without data Feature use Status request Data request Status request with/without data Access code

--X -------------------

The access code for subscriber controlled input consists of a maximum of 6 characters or, for GeoCENTREX subscribers, a maximum of 5 characters. It can be formed from the symbols 5 , # and the service code (SC) with the digits 0 ... 9. The operator can specify the character strings for the access code. Separate service codes (SC) for GFR including alarm calls and GFR excluding alarm calls. Differences for pulse dialing The selected digits are not obligatory; other digits can be input (depending on the existing numbering plan). 1111 at the beginning of an input in place of 5 1112 at the beginning of an input in place of # 1113 at the beginning of an input in place of 5 # 5 as a disconnecting signal after the feature code, not relevant # after the subscriber controlled input, not relevant Acknowledgments after subscriber controlled input The following tones, announcements and display texts are examples and can be administrated by the operator. The display texts can be changed to suit individual projects. The subscriber controlled input can be acknowledged by: Tones ringing tone acceptance tone subscriber busy tone or number unobtainable tone (NU)

A30828-X1150-B637-1-7629

General Facility Reset (GFR)

Information Analog/ISDN/GeoCENTREX

Announcements subscriber controlled input successful subscriber controlled input unsuccessful feature is already activated feature is not activated feature is not available wrong input Display texts wrong input not authorized request rejected successful unsuccessful not available

3.1

Analog
Start PIN optional End DT (( ) IND SC PIN)

3.2

ISDN
Start PIN optional MSN optional BC optional End DT (( ( ( IND ) SC PIN) MSN) BC)

MSN = 0 MSN = MSN MSN = none BC = 0 BC = 01 BC = none

GFR all numbers GFR for given multiple subscriber numbers GFR for the number derived from the calling party address of the basic call GFR all services GFR for the given service GFR all voice services

A30828-X1150-B637-1-7629

Information Analog/ISDN/GeoCENTREX

General Facility Reset (GFR)

3.3
3.3.1

GeoCENTREX
Analog
For inputs, see subscriber procedure Analog.

3.3.2

ISDN
For inputs, see subscriber procedure ISDN.

3.4

Additional possibilities for feature control


Feature Automatic Feature Subscription (AFS) Remote Subscriber Controlled Input (RSCI) Feature Control Offline (FCOFF) Subscriber Controlled Input via Internet (ISCI) Use ----X ---

3.5

Legend
Introduces activation from terminal or introduces input from terminal or used as separator Introduces deactivation from terminal or introduces cancellation from terminal or used at end of feature input Enter ... Lift handset Replace handset () BC DT IND MSN PIN SC Optional input Basic code Dial tone Indication (tone, announcement, display texts) Multiple subscriber number Personal identification number (4 to 12 digits) Service code

A30828-X1150-B637-1-7629

General Facility Reset (GFR)

Information Analog/ISDN/GeoCENTREX

4 Call charge registration


Call charge registration is possible with: Automatic Message Accounting with Individual Call Charge Registration Pulse Metering Message Detail Recording (MDR) for GeoCENTREX Flat rate Automatic Message Accounting with Individual Call Charge Registration (AMA) and Pulse Metering can be combined. One or more call charge pulses can be generated for Pulse Metering. Charges for feature input and feature usage The charges for operator inputs, successful subscriber controlled input and feature usage are assigned to the subscriber. The following call charge registration is possible: Facility input by operator (FAIO) Facility input by subscriber (FAIS) Facility usage (FAU) Action Activate Deactivate Enter data Delete data Assign authorization Remove authorization Assign authorization to modify Remove authorization to modify Status request, data request Use FAIO --X ------X X ------FAIS --X ----------------FAU ---------------------

10

A30828-X1150-B637-1-7629

Information Analog/ISDN/GeoCENTREX

General Facility Reset (GFR)

5 Administration
The operator can perform all administration functions on the NetManager by means of user-friendly applications or MML commands. Feature authorization The network operator assigns authorization for the feature when requested by the subscriber. Subscriber access types The feature can be used with the following types of subscriber access: Type Subscriber Analog Main station Basic access PBX PBX with BA and/or PA PBX line PBX line with Direct Dialing In (DDI) PBX line, connected like a subscriber Coinbox Emergency call station MLHG line Basic attendant console MAC attendant console ISDN basic The allocation and usage of the feature are service specific. The basic code may be different, depending on the individual project. ISDN basic service All services Circuit mode: speech Circuit mode: 64 kbit/s unrestricted Circuit mode: 3.1 kHz audio Circuit mode: 7 kHz audio Telephony 3.1 kHz Teletex 64 kbit/s Fax group 4 Basic code 00 01 02 03 04 32 33 34 X --X --X X X ----------ISDN --X --X X --X ----------GeoCENTREX Analog X --X --X X X ------X --ISDN --X --X X --X ------X X

A30828-X1150-B637-1-7629

11

General Facility Reset (GFR)

Information Analog/ISDN/GeoCENTREX

ISDN basic service Videotex Video telephony Fax group 2/3 Telephony 7 kHz Call charge registration For more information, please refer to OMN:EXCH-TA. System administration

Basic code 35 36 37 38

The following feature data can be administrated in the network node: options for subscriber controlled input, as GFR including or excluding alarm calls display and modication of network node options creation of announcements recording by means of trafc measurement For more information, please refer to OMN:EXCH-SY. Subscriber administration For more information, please refer to OMN:EXCH-SU. GeoCENTREX administration For more information, please refer to OMN:EXCH-CTX.

6 Requirements
Hardware No special hardware is needed. Signaling Subscriber signaling Analog Dual-tone multi-frequency (DTMF) Pulse dialing Frequency shift keying (FSK) ISDN Digital subscriber signaling system no.1 (DSS1) Subscriber interfaces The following interfaces for subscriber access can be used: DLU LTG V5.1 interface V5.2 interface