You are on page 1of 16

Silver-Lube

Corrosion resistant bearing units

INDEX

Silver-Lube Units
Introduction

Unit Dimensions

End Covers

Silver-Lube Housings
Properties of PBT

Housing Dimensional Accuracy 9/10


Housing Strength
Static Electricity Generation

11/12
12

Silver-Lube Bearing Inserts


Grease, Temperature Range
and Component Materials

14

Designations, Dimensions
and Weights

14

Shaft Tolerances

14

and Permissible Speeds

Set Screw Tightening Torques

15

Bore Tolerance

15

WITHSTANDS FREQUENT
WASHDOWNS RESISTING
Corrosion
Detergents
Chemicals

STAINLESS STEEL
Grease nipple
Bolt hole liners
Set screws
Flinger
Seal core
Bearing rings,
cage and balls

RHP SILVER-LUBE

CORROSION RESISTANT UNITS


STAINLESS STEEL BEARING INSERTS
EFFECTIVE, EFFICIENT SEALING
APPROVED FOOD GRADE GREASE
WIDE OPERATING TEMPERATURE
END COVERS AVAILABLE

INTRODUCTION
The RHP Silver-Lube series is a range of corrosion resistant
bearing units specifically for use in industries where frequent
thorough washdowns are necessary, optimum hygiene standards
are required and good chemical resistance is important over a
wide temperature range.
The units are available in pillow block, two-bolt flange, four-bolt flange
and take-up unit configurations and are capable of accommodating
initial misalignment from mounting errors. In operation the units
have proven reliability in the most hostile applications.
Relubrication is possible for long trouble-free life,
minimising maintenance, maximising productivity
and helping maintain hygiene standards.
Silver-Lube housings are made from PBT
thermoplastic resin which, in addition to being
non-corrodable, is resistant to detergents and a
wide range of chemicals. The housings are paint and
coating free which prevents chipping or flaking and have smooth
surfaces to assist thorough washdowns.
Silver-Lube bearing inserts are made from stainless steel, are
provided with effective, efficient sealing arrangements and are
charged with an aluminium complex, high temperature approved food

THERMOPLASTIC
MOULDED HOUSING
No coating
No cracking
No peeling
Solid base

grade grease, as standard.


Full technical specifications, application details and descriptions of
the Silver-Lube range are provided within this document.

FROM BOTTLING PLANTS TO FISHERIES


4

A1

H2 S
G Bolt Dia

N1

UNIT DIMENSIONS
Silver-Lube mounting details are dimensionally interchangeable with
the traditional RHP Self-Lube range. However, some non-critical
dimensions do differ, see tables below.

For permissible bearing speeds, please see page 14.

H1
J
L

N
A

PNP SERIES

PNP Silver-Lube Pillow Blocks Unit Dimensions

Table 1
RHP
SHAFT BASIC HOUSING
DESIGNATION DIA. INSERT GROUP
PNP20CR
PNP3/4CR
PNP25CR
PNP1CR
PNP30CR
PNP1.3/16CR
PNP1.1/4RCR
PNP35CR
PNP1.1/4CR
PNP1.7/16CR
PNP40CR
PNP1.1/2CR

20
3/4"
25
1"
30
1.3/16"
1.1/4"
35
1.1/4"
1.7/16"
40
1.1/2"

J1020
J1020
J1025
J1025
J1030
J1030
J1030
J1035
J1035
J1035
J1040
J1040

2
2
3
3
4
4
4
5
5
5
6
6

H1

H2

N1

A1

WEIGHT
(kg)

127.2
127.2
140.2
140.2
162.2
162.2
162.2
167.2
167.2
167.2
184.2
184.2

33.3
33.3
36.5
36.5
42.9
42.9
42.9
47.6
47.6
47.6
49.2
49.2

14.2
14.2
14.5
14.5
17.8
17.8
17.8
18.0
18.0
18.0
19.5
19.5

65.9
65.9
71.9
71.9
83.9
83.9
83.9
94.9
94.9
94.9
98.9
98.9

94.9
94.9
104.9
104.9
118.9
118.9
118.9
126.9
126.9
126.9
136.8
136.8

11.0
11.0
11.0
11.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0

14.2
14.2
14.2
14.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2

M10
M10
M10
M10
M12
M12
M12
M12
M12
M12
M12
M12

37.8
37.8
37.8
37.8
45.8
45.8
45.8
47.8
47.8
47.8
53.8
53.8

22.5
22.5
24.5
24.5
27.0
27.0
27.0
32.5
32.5
32.5
36.0
36.0

31.0
31.0
34.0
34.0
38.1
38.1
38.1
42.9
42.9
42.9
49.2
49.2

12.7
12.7
14.3
14.3
15.9
15.9
15.9
17.5
17.5
17.5
19.0
19.0

0.27
0.27
0.39
0.39
0.52
0.52
0.52
0.72
0.72
0.72
0.99
0.99

All dimensions in mm except inch shaft sizes.

L
J

G Bolt
Dia

A1
A
A4

B S

PSF SERIES

Table 2

PSF Silver-Lube Four-Bolt Flange Unit Dimensions

RHP
SHAFT BASIC HOUSING
DESIGNATION DIA. INSERT GROUP
PSF20CR
PSF3/4CR
PSF25CR
PSF1CR
PSF30CR
PSF1.3/16CR
PSF1.1/4RCR
PSF35CR
PSF1.1/4CR
PSF1.7/16CR
PSF40CR
PSF1.1/2CR

20
3/4"
25
1"
30
1.3/16"
1.1/4"
35
1.1/4"
1.7/16"
40
1.1/2"

J1020
J1020
J1025
J1025
J1030
J1030
J1030
J1035
J1035
J1035
J1040
J1040

2
2
3
3
4
4
4
5
5
5
6
6

86.5 63.5 M10


86.5 63.5 M10
95.0 70.0 M10
95.0 70.0 M10
107.5 83.0 M10
107.5 83.0 M10
107.5 83.0 M10
117.5 92.0 M12
117.5 92.0 M12
117.5 92.0 M12
130.5 102.0 M12
130.5 102.0 M12

A1

A4

WEIGHT
(kg)

27.8
27.8
27.9
27.9
31.5
31.5
31.5
34.8
34.8
34.8
37.5
37.5

36.3
36.3
36.7
36.7
41.4
41.4
41.4
46.9
46.9
46.9
53.2
53.2

13.4
13.4
14.3
14.3
14.3
14.3
14.3
15.5
15.5
15.5
17.1
17.1

31.0
31.0
34.0
34.0
38.1
38.1
38.1
42.9
42.9
42.9
49.2
49.2

12.7
12.7
14.3
14.3
15.9
15.9
15.9
17.5
17.5
17.5
19.0
19.0

0.28
0.28
0.34
0.34
0.50
0.50
0.50
0.74
0.74
0.74
0.98
0.98

All dimensions in mm except inch shaft sizes.

Table 3 PSFT Silver-Lube Two-Bolt Flange Unit Dimensions

A1
L

A
A4

G Bolt
Dia

RHP
SHAFT BASIC HOUSING
DESIGNATION DIA. INSERT GROUP
PSFT20CR
PSFT3/4CR
PSFT25CR
PSFT1CR
PSFT30CR
PSFT1.3/16CR
PSFT1.1/4RCR
PSFT35CR
PSFT1.1/4CR
PSFT1.7/16CR
PSFT40CR
PSFT1.1/2CR

B S

PSFT SERIES

20
3/4"
25
1"
30
1.3/16"
1.1/4"
35
1.1/4"
1.7/16"
40
1.1/2"

J1020
J1020
J1025
J1025
J1030
J1030
J1030
J1035
J1035
J1035
J1040
J1040

2
2
3
3
4
4
4
5
5
5
6
6

A1

A4

WEIGHT
(kg)

64.1
64.1
68.4
68.4
80.1
80.1
80.1
90.1
90.1
90.1
100.1
100.1

113.3
113.3
130.3
130.3
148.3
148.3
148.3
163.3
163.3
163.3
175.3
175.3

90.0
90.0
99.0
99.0
117.0
117.0
117.0
130.0
130.0
130.0
144.0
144.0

M10
M10
M10
M10
M10
M10
M10
M12
M12
M12
M12
M12

26.5
26.5
29.1
29.1
30.5
30.5
30.5
32.8
32.8
32.8
37.5
37.5

33.7
33.7
36.7
36.7
41.2
41.2
41.2
43.4
43.4
43.4
51.7
51.7

11.4
11.4
13.4
13.4
13.4
13.4
13.4
16.1
16.1
16.1
20.0
20.0

31.0
31.0
34.0
34.0
38.1
38.1
38.1
42.9
42.9
42.9
49.2
49.2

12.7
12.7
14.3
14.3
15.9
15.9
15.9
17.5
17.5
17.5
19.0
19.0

0.24
0.24
0.30
0.30
0.44
0.44
0.44
0.64
0.64
0.64
0.89
0.89

All dimensions in mm except inch shaft sizes.

A
A1

L1

H1

H3

G1

G Thread
L4

A2

PST SERIES

PST Silver-Lube Take-Up Units Unit Dimensions

Table 4
RHP
SHAFT BASIC HOUSING
DESIGNATION DIA. INSERT GROUP L

L1

L4

H1

H3

G1

A1

A2

WEIGHT
(kg)

PST20CR
PST3/4CR
PST25CR
PST1CR
PST30CR
PST1.3/16CR
PST1.1/4RCR
PST35CR
PST1.1/4CR
PST1.7/16CR
PST40CR
PST1.1/2CR

64.0
64.0
64.0
64.0
76.0
76.0
76.0
76.0
76.0
76.0
85.0
85.0

47.0
47.0
47.0
47.0
63.0
63.0
63.0
63.0
63.0
63.0
80.0
80.0

88.0
88.0
88.0
88.0
102.0
102.0
102.0
102.0
102.0
102.0
114.0
114.0

35.0
35.0
35.0
35.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0

75.8
75.8
75.8
75.8
88.8
88.8
88.8
88.8
88.8
88.8
101.8
101.8

M16x2.00
M16x2.00
M16x2.00
M16x2.00
M16x2.00
M16x2.00
M16x2.00
M16x2.00
M16x2.00
M16x2.00
M16x2.00
M16x2.00

22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5

27.5
27.5
27.5
27.5
34.5
34.5
34.5
34.5
34.5
34.5
34.0
34.0

24.5
24.5
24.5
24.5
30.0
30.0
30.0
30.0
30.0
30.0
32.0
32.0

12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
16.2
16.2

31.0
31.0
34.0
34.0
38.1
38.1
38.1
42.9
42.9
42.9
49.2
49.2

12.7
12.7
14.3
14.3
15.9
15.9
15.9
17.5
17.5
17.5
19.0
19.0

0.32
0.32
0.36
0.36
0.53
0.53
0.53
0.74
0.74
0.74
1.00
1.00

20
3/4"
25
1"
30
1.3/16"
1.1/4"
35
1.1/4"
1.7/16"
40
1.1/2"

J1020
J1020
J1025
J1025
J1030
J1030
J1030
J1035
J1035
J1035
J1040
J1040

2
2
3
3
4
4
4
5
5
5
6
6

99.0
99.0
99.0
99.0
125.0
125.0
125.0
125.0
125.0
125.0
140.0
140.0

All dimensions in mm except inch shaft sizes.

END COVERS
Polypropylene end covers are available to fit all Silver-Lube housings.
End covers can be used at temperatures ranging from 20C to
+90C. They may be used as additional protection for the bearing in
adverse environmental conditions as well as an aid to meeting safety
requirements.

End-Cover
End Cover

END COVER DETAIL

Table 5
HOUSING
GROUP
Group 2
Group 3
Group 4
Group 5
Group 6

End Cover Dimensions


END COVER
REFERENCE
P20P
P25P
P30P
P35P
P40P

DIMENSION
D
50
55
64
74
84

DIMENSION
L
23
25
30
32
37

All dimensions in mm.

SILVER-LUBE HOUSINGS
Silver-Lube housings are manufactured from highgrade PBT, a high quality thermoplastic which
has excellent strength, rigidity, dimensional stability and chemical resistance.

PROPERTIES OF PBT

PROPERTY

UNITS

TEST
METHOD

VALUES

PHYSICAL
Density
Water Absorption(23C)
Mould Shrinkage
Moisture Absorption (23)

g/cm3
%
%
%

DIN 53479
DIN 53495

DIN 53714

1.53
0.5
0.4
0.2

MECHANICAL
Tensile Yield Strength
Elongation At Break
Flexural Strength
Flexural Modulus
Notched IZOD Impact

MPa
%
MPa
MPa
J/m

ASTM D638
ASTM D638
ASTM D790
ASTM D790
ASTM D256

130
3.5
180
7,000
120

C
C
C

DIN 53461
DIN 53461

UL 94
IEC 695/2/1

210
220
225
HB

THERMAL
HDT At Load 1.8 Mpa
HDT AT Load 0.45 Mpa
Melting Point
UL Flammability ("Thickness)
Max. Temp In Glow Wire Test
2 mm thickness
4 mm thickness

ELECTRICAL
Dielectric Constant At 1 MHz
Dielectric Strength
Volume Resistivity
Surface Resistivity

750
960

kV/mm
ohm x cm
ohm

IEC 250
VDE 0303/2
VDE 0303/2
VDE 0303/3

3.8
34
>1015
>1015

PLASTIC HOUSING DIMENSIONAL ACCURACY


Table 6

PNP Silver-Lube Pillow Blocks Dimensional Accuracy

HOUSING
GROUP
2
3
4
5
6

DEVIATIONS
H

DEVIATIONS
J

150
150
150
150
150

700
700
700
700
700

H
J

All dimensions in m.

Table 7
HOUSING
GROUP

PNP SERIES

PSF Silver-Lube Four-Bolt Flange Dimensional Accuracy


CENTRE HEIGHT
A

HOLE CENTRES
J

FIXING HOLE LOCATION


X

500
500
500
500
500

700
700
700
700
700

200
200
200
200
200

2
3
4
5
6

X M

All dimensions in m.

A
J

PSF SERIES
Table 8
HOUSING
GROUP

PSFT Silver-Lube Two-Bolt Flange Dimensional Accuracy


CENTRE HEIGHT
A

HOLE CENTRES
J

FIXING HOLE LOCATION


X

500
500
500
500
500

700
700
700
700
700

200
200
200
200
200

2
3
4
5
6

X M

All dimensions in m.

PSFT SERIES
PST Silver-Lube Take-Up Housings Dimensional Accuracy

HOUSING
GROUP
2
3
4
5
6

DEVIATIONS
A

DEVIATIONS
H

+200/0
+200/0
+200/0
+200/0
+200/0

0/-500
0/-500
0/-500
0/-500
0/-500

Table 9

All dimensions in m.

PST SERIES

10

HOUSING STRENGTH
Housing load carrying capacity varies depending on the application loading regime, which may be intermittent,
continuous or cyclical. Maximum housing loads are given in tables 10, 11, 12 and 13. These loads must not be
exceeded without prior consultation with NSK.
Published housing maximum load capacities do not allow for any reduction in housing strength caused by exposure
of the housing to chemicals, water, steam, heat, ultraviolet light or any combination of these factors. If any of these
factors are present in the application the designer or end-user must establish the effect of these exposures and
reduce the published maximum housing load accordingly.
To maximise load carrying capacity it is recommended that washers are used with the fixing bolts. Tables 10, 11
and 12 also detail maximum fixing bolt tightening torques.
P2

P3

P4

P1

PNP SERIES
PNP Silver-Lube Pillow Blocks Housing Load Capacity

Table 10
RHP
DESIGNATION

MAXIMUM HOUSING LOAD (N) AT 20C


P2
P3

P1

P4

INTERMITTENT CONTINUOUS CYCLICAL INTERMITTENT CONTINUOUS CYCLICAL INTERMITTENT CONTINUOUS CYCLICAL INTERMITTENT CONTINUOUS CYCLICAL
LOADING
LOADING LOADING
LOADING
LOADING LOADING
LOADING
LOADING LOADING
LOADING
LOADING LOADING

PNP20CR
PNP3/4CR
PNP25CR
PNP1CR
PNP30CR
PNP1.3/16CR
PNP1.1/4RCR
PNP35CR
PNP1.1/4CR
PNP1.7/16CR
PNP40CR
PNP1.1/2CR

3500
3500
4000
4000
5000
5000
5000
6000
6000
6000
10700
10700

1700
1700
2000
2000
2500
2500
2500
3000
3000
3000
5300
5300

800
800
1000
1000
1200
1200
1200
1500
1500
1500
2900
2900

2800
2800
3100
3100
3500
3500
3500
4300
4300
4300
8000
8000

1400
1400
1500
1500
1800
1800
1800
2100
2100
2100
4000
4000

800
800
800
800
1000
1000
1000
1200
1200
1200
2200
2200

Table 11

2600
2600
2600
2600
4000
4000
4000
4100
4100
4100
6800
6800

1300
1300
1700
1700
2600
2600
2600
3200
3200
3200
5200
5200

700
700
900
900
1300
1300
1300
1600
1600
1600
2600
2600

400
400
500
500
700
700
700
900
900
900
1400
1400

MAXIMUM HOUSING LOAD (N) AT 20C


F1
F2
INTERMITTENT CONTINUOUS CYCLICAL INTERMITTENT CONTINUOUS CYCLICAL
LOADING
LOADING LOADING
LOADING
LOADING LOADING

F2

F1

700
700
700
700
1100
1100
1100
1100
1100
1100
1900
1900

PSF Four-Bolt Flange Housing Load Capacity

RHP
DESIGNATION

PSF SERIES

1300
1300
1300
1300
2000
2000
2000
2100
2100
2100
3400
3400

PSF20CR
PSF3/4CR
PSF25CR
PSF1CR
PSF30CR
PSF1.3/16CR
PSF1.1/4RCR
PSF35CR
PSF1.1/4CR
PSF1.7/16CR
PSF40CR
PSF1.1/2CR

MAXIMUM
FIXING BOLT
TORQUE (Nm)
18
18
25
25
30
30
30
35
35
35
40
40

3100
3100
3500
3500
4600
4600
4600
6200
6200
6200
6200
6200

1600
1600
1700
1700
2300
2300
2300
3100
3100
3100
3100
3100

900
900
1000
1000
1300
1300
1300
1700
1700
1700
1700
1700

1300
1300
1300
1300
2200
2200
2200
2600
2600
2600
4000
4000

700
700
700
700
1100
1100
1100
1300
1300
1300
2000
2000

400
400
400
400
600
600
600
700
700
700
1100
1100

MAXIMUM
FIXING BOLT
TORQUE (Nm)
18
18
25
25
30
30
30
35
35
35
40
40

11

T3

T1

T2

PSFT SERIES
PSFT Silver-Lube Two-Bolt Flange Housing Load Capacity

Table 12
RHP
DESIGNATION

MAXIMUM HOUSING LOAD (N) AT 20C


T2

T1

T3

INTERMITTENT CONTINUOUS CYCLICAL INTERMITTENT CONTINUOUS CYCLICAL INTERMITTENT CONTINUOUS CYCLICAL


LOADING
LOADING LOADING
LOADING
LOADING LOADING
LOADING
LOADING LOADING

PSFT20CR
PSFT3/4CR
PSFT25CR
PSFT1CR
PSFT30CR
PSFT1.3/16CR
PSFT1.1/4RCR
PSFT35CR
PSFT1.1/4CR
PSFT1.7/16CR
PSFT40CR
PSFT1.1/2CR

4400
4400
4400
4400
5900
5900
5900
6400
6400
6400
9000
9000

2200
2200
2200
2200
2900
2900
2900
3200
3200
3200
4500
4500

1200
1200
1200
1200
1600
1600
1600
1700
1700
1700
2500
2500

U
U

PST SECTION

PST20CR
PST3/4CR
PST25CR
PST1CR
PST30CR
PST1.3/16CR
PST1.1/4RCR
PST35CR
PST1.1/4CR
PST1.7/16CR
PST40CR
PST1.1/2CR

900
900
1500
1500
1600
1600
1600
2000
2000
2000
2000
2000

500
500
800
800
900
900
900
1100
1100
1100
1100
1100

1300
1300
1400
1400
2000
2000
2000
2800
2800
2800
3300
3300

700
700
700
700
1000
1000
1000
1400
1400
1400
1600
1600

400
400
400
400
500
500
500
800
800
800
900
900

PST Silver-Lube Take-Up Housing Load Capacity

Table 13
RHP
DESIGNATION

1900
1900
3000
3000
3300
3300
3300
3900
3900
3900
3900
3900

MAXIMUM
FIXING BOLT
TORQUE (Nm)
18
18
25
25
30
30
30
35
35
35
40
40

MAXIMUM HOUSING LOAD (N) AT 20C


U
Intermittent
Continuous
Loading
Loading
5700
2800
5700
2800
5400
2700
5400
2700
8100
4000
8100
4000
8100
4000
7800
3900
7800
3900
7800
3900
8100
4000
8100
4000

Cyclical
Loading
1600
1600
1500
1500
2300
2300
2300
2200
2200
2200
2300
2300

MRFL (kN)
17.01
17.01
16.25
16.25
24.32
24.32
24.32
23.52
23.52
23.52
24.26
24.26

Note that there is no Maximum Fixing Bolt Torque applicable for Take-Up Units.

STATIC ELECTRICITY GENERATION


Static electricity may be generated by Silver-Lube bearing units under certain application conditions.
Silver-Lube bearings are therefore not recommended for use in explosive or flammable environments. If Silver-Lube
bearing units are used in flammable or explosive applications the bearing insert must be earthed.

12

FROM FOOD TO PHARMACEUTICALS

13

SILVER-LUBE BEARING INSERTS

h
M

Two Set
Screws (SS)
120 Apart

Radius r
D

Original Chevron greased inserts can be identified by there being only


three markings on the flinger, for example: RHP JAPAN J102525GCR. Inserts charged with an aluminium complex food grade
grease can be identified by the presence of an additional letter
between RHP and Japan; for example inserts are marked with a K
(or M) to give RHP K JAPAN J1025-25GCR.

S1

The grease in this product is an aluminium complex food grade grease.


In the event of relubricating being necessary, this type of grease is the
first choice replacement. Please note that Silver-Lube bearings were
previously charged with Chevron Poly FM2 grease, which is
incompatible with the current aluminium complex food grade grease.

If an aluminium complex food grade grease is not available, it is


essential that any alternative grease is USDA H1 approved and ideally
chemically compatible with the original grease. If chemical
compatibility cannot be assured, then it is recommended that the
original grease is completely flushed out from the system before
relubrication. NSK should be consulted if necessary.

INSERT DESIGNATIONS, DIMENSIONS AND WEIGHTS


Table 14

Insert Dimensions

RHP
DESIGNATION

BORE DIA

S1

SS

Cr (N)

Cor (N)

WEIGHT
(kg)

20
3/4"
25
1"
30
1.3/16"
1.1/4"
35
1.1/4"
1.7/16"
40
1.1/2"

47
47
52
52
62
62
62
72
72
72
80
80

16
16
17
17
19
19
19
20
20
20
21
21

31.0
31.0
34.0
34.0
38.1
38.1
38.1
42.9
42.9
42.9
49.2
49.2

12.7
12.7
14.3
14.3
15.9
15.9
15.9
17.5
17.5
17.5
19.0
19.0

18.3
18.3
19.7
19.7
22.2
22.2
22.2
25.4
25.4
25.4
30.2
30.2

1.5
1.5
1.5
1.0
1.5
1.0
1.0
2.0
2.0
1.5
2.0
2.0

4.0
4.0
3.5
3.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

5.0
5.0
5.5
5.5
6.0
6.0
6.0
6.5
6.5
6.5
8.0
8.0

M6
M6
M6
M6
M6
M6
M6
M8
M8
M8
M8
M8

9910
9910
10820
10820
15000
15000
15000
19820
19820
19820
22540
22540

5350
5350
6300
6300
9050
9050
9050
12300
12300
12300
14300
14300

0.16
0.16
0.20
0.20
0.32
0.32
0.32
0.48
0.48
0.48
0.64
0.64

J1020-20GCR
J1020-3/4GCR
J1025-25GCR
J1025-1GCR
J1030-30GCR
J1030-1.3/16GCR
J1030-1.1/4GCR
J1035-35GCR
J1035-1.1/4GCR
J1035-1.7/16GCR
J1040-40GCR
J1040-1.1/2GCR

All dimensions in mm except inch bores. Cr = basic dynamic load rating. Cor = basic static load rating.
Contact NSK for guidance on life estimation.

COMPONENT MATERIALS

SHAFT TOLERANCES
AND PERMISSIBLE SPEEDS

Table 15
STANDARD

BEARING
RINGS

BALL

FLINGER

SET SCREW

CAGE

JIS
AISI/ASTM

SUS440C
AISI440C

SUS440C
AISI440C

SUS304
AISI304

SUS410
AISI410

SUS304
AISI304

Bearing insert permissible speed is dependent on


shaft tolerance.
For higher speed applications an ISO h7 shaft
tolerance is recommended. An ISO h9 shaft
tolerance may be used for low speed applications.
For more details see table 16.

Table 16

Tolerances and Speeds


ISO h7

BASIC
BEARING
INSERT
J1020
J1025
J1030
J1035
J1040

14

ISO h9

BEARING
LIMITING
SPEED
(RPM)

SHAFT
TOLERANCE
HIGH
(0.001 mm UNITS)

SHAFT
TOLERANCE
LOW
(0.001 mm UNITS)

BEARING
LIMITING
SPEED
(RPM)

SHAFT
TOLERANCE
HIGH
(0.001 mm UNITS)

SHAFT
TOLERANCE
LOW
(0.001 mm UNITS)

2900
2600
2180
1870
1650

0
0
0
0
0

-21
-21
-21
-25
-25

1490
1300
1090
940
830

0
0
0
0
0

-52
-52
-52
-62
-62

SET SCREW TIGHTENING TORQUES


Set screws for Silver-Lube bearing inserts are manufactured from
stainless steel and can fracture if overtightened. The limiting set screw
torques listed below should not be exceeded.

Table 17
RHP
DESIGNATION
J1020-20GCR
J1020-3/4GCR
J1025-25GCR
J1025-1GCR
J1030-30GCR
J1030-1.3/16GCR
J1030-1.1/4GCR
J1035-35GCR
J1035-1.1/4GCR
J1035-1.7/16GCR
J1040-40GCR
J1040-1.1/2GCR

Tightening Torques
SET SCREW

MAXIMUM TIGHTENING
TORQUE (Nm)

M6 x 7.0 LONG
M6 x 7.0 LONG
M6 x 7.0 LONG
M6 x 7.0 LONG
M6 x 7.0 LONG
M6 x 7.0 LONG
M6 x 7.0 LONG
M8 x 9.0 LONG
M8 x 9.0 LONG
M8 x 9.0 LONG
M8 x 9.0 LONG
M8 x 9.0 LONG

4
4
4
4
4
4
4
8
8
8
8
8

BORE TOLERANCE
Silver-Lube inner ring bore tolerances are on the plus side of the
nominal bore. This enables the bearing to slip freely over standard
shafting.

Table 18
NOMINAL BORE
DIAMETER d (mm)
OVER
INCLUDING
10
18
18
30
30
50

Bore Tolerances
BORE TOLERANCE
(0.001 mm UNITS)
MAX
MIN
+15
0
+18
0
+21
0

In line with our policy of continuous improvement, we reserve the right to amend the details in this catalogue
without prior notice.

15

Designed and produced by Wyatt International Limited, Birmingham.

Conmutador: +52(55) 5305-1320


Fax: +52(55) 5305-1326
Nextel ID: 52*40085*2
Lada sin Costo Mxico: 01800 552 9428
mail: ventas@rodamientos-samper.com.mx

Every care has been taken to ensure that the


information in this publication is accurate but no liability
can be accepted for any errors or omissions.
Copyright NSK 2003
The contents of this publication are the copyright of
the publishers.
Printed in England Ref: SVLB/D/E/E/I/5.03