You are on page 1of 22

TELEMAR

Solues para voc

Alcatel 1660SM
STM-64 Multiservice Metro Node

1660SM Rel. 5.0

STM-64 Multiservice Metro Node - 1660SM Rel. 5.0

OBJETIVO: Descrever as principais funcionalidades e estrutura do OMSN's 1660SM Rel.

1- Descrio do Sistema: ? Alcatel Optmex Multi Service Node (OMNS) compatvel tanto com sistemas PDH's quanto para SDH's. ? OMNS pode ser configurado como mltiplo terminal de linha, mltiplo add-drop ou como cross-connect. ? OMNS tem ATM integrado, equipado com Ethernet, Fast Ethernet, Gigabit Ethernet e Ethernet Switch's (ISA).

2 Mbit/s 34 / 45 Mbit/s 140 Mbit/s ATM

CWDM SIGNAL

STM-1

OMSN

STM-4

STM-16 Ethernet MPLS FIBER CHANNEL STM-64

DIG. VIDEO

ESCON

FICON

TIPO DE PROTEES: ? Equipament Protection EPS ? Protection Network MSP SNCP/N e SNCP/I 2F MS-SPRING 4F MS-SPRING D&C

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

OC-3

FDDI

12/07/2006

ELABORADO POR

ANDR GESTEIRA

2- Diferenas entre equipamentos ADMs e equipamentos OMSN:

ADM
AGGR.

MATRIX

AGGR.

TRIB.

TRIB.

TRIB.

PORT

PORT

PORT

MATRIX OMSN
PORT PORT

OBS.: 1) Nos equipamentos ADM temos que especificar as portas que sero agregadas e as tributrias; 2) Nos OMSN no este tipo de diferenciao, dando assim maior flexibilidade na criao de cross-conexes; 3) Compatibilidade total entre equipamentos ADM e OMSN;

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

3- Funcionamento interno das do SHELF:

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

4- Comunicao interna (detalhada):


PORT ASICS

EC
MIB

SC

PORT ASICS

PORT ASICS

ASICS = No h mais falhas de verso (Application Specific Integrated Circuit)

ISA
4- Barramentos:

MIB

OBS.: se for colocado uma placa nova esta placa se comunica com a SC, na qual a mesma interroga a MIB do equipamento na EC, para que a mesma atualize a verso de acordo com a que esta sendo usada.

As entradas de RA, QMD, QB, HK / RE das placas CONGIs no so protegidas.

BARRAMENTO DE GERNCIA

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

5- Sistema Mecnico do Shelf:

REA DE PORTAS

AREA DE ACESSO

REA DE ACESSO Slot 1-9, 13-21: placas de acesso Slot 10: CONGI A Slot 11: SERVICE Slot 12: CONGI B

REA DE PORTAS Slot 22: EQUICO (PQ2 / EC) Slot 23, 40: Matrix N (Matrix E) Slot 24-39: High Speed / Low Speed port

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

1 2 3 4 5 6 7 8 9 10 11 12 13 13 14 15 16 17 18 19 20

22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41

MATRIXA

MATRIXB

STM-16 ou STM-64 PLACAS COMUNS (Common Cards) LS CARD HS Cards ISA CWDM CARD AMPLIFIER

Slot onde sempre estar a proteo de 2MB.

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

TAMPA CEGA

ENHANCED

ENHANCED

ENHANCED

ENHANCED

ENHANCED

ENHANCED

ENHANCED

EQUICO

ENHANCED

TBUS

TBUS

2MB CARDS
PORT CARD SLOT 24 27 30 32 SPARE 33 36 39 ACCESS CARD SLOT 1, 2, 3 4, 5, 6 7, 8, 9 REQUERIDA ACCESS CARD 13, 14, 15 16, 17, 18 19, 20, 21

HS e ISA CARDS
PORT CARD SLOT ACCESS CARD SLOT

ISA PR CARDS
PORT CARD SLOT LEFT MIDDLE RIGHT CARD CARD CARD ACCESS ACCESS ACCESS SLOT SLOT SLOT

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39

2 3 4 5 6 7 8 9

25-26 26-27 27-28 28-29 29-30 30-31 31-32

2-3 3-4 4-5 5-6 6-7 7-8 8-9 /

3-4 4-5 5-6 6-7 7-8 8-9 /

4-5 5-6 6-7 7-8 8-9 / /

13 14 15 16 17 18 19 20

32-33 33-34 34-35 35-36 36-37 37-38

13-14 14-15

13-14 14-15 15-16 14-15 15-16 16-17 15-16 16-17 17-18 16-17 17-18 18-19 17-18 18-19 19-20

38-39 18-19 19-20 20-21

OBS.: Para determinada placa inserida na rea de portas, ela precisar de uma determinada placa na rea de acesso; A placa de proteo para tributrios de 2MB devem ser colocadas no slot 32; Placas STM-4, STM-16, STM-64, ATM, GIGABIT Ethernet, PR-EA, 4xANY, ES1-8FE, ES1-8FX e ES4-8FE no possuem placas de acesso; 6- Sincronismo:

SELETOR A

Squelch A

SELETOR C

Service Card T4 / T5

Port Card SDH / PDH

Squelch B

T1 / T2 T3 / T6 SERVICE Card SELETOR B SETG T0 Todas as Unidades OSC SETS

PLACA MATRIX

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

7- Descrio do Hardware: 7.1- PLACAS LS e HS:

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

ACRONYM P4S1N

SLOTS 24 A 29

Mdulos STM-1: Eletrico-SC / PC-FC /PC ICMI, IS-1.1, IL-1.1, IL-1.2, MM1 ACRONYM P4E4N SLOTS 24 A 29

Mdulos STM-1: Eletrico-SC / PC-FC /PC ICMI, IS-1.1, IL-1.1, IL-1.2, MM1 ACRONYM A2S1 SLOTS 24 A 29

Mdulos STM-1: Eletrico-SC / PC-FC /PC ICMI, IS-1.1, IL-1.1, IL-1.2, MM1 MDULOS - ESPECIFICAO ? ICMI - Interface - Cdigo - Marca - Inverso (140Mb PDH / 155Mb SDH) ? IS1.1 - Interface Short Haul STM-1 (155Mb) - = 1310nm (aproximandamente 15 Km) ? IL1.1 - Interface Long Haul STM-1 (155Mb) - = 1310nm (aproximandamente 40 Km) ? IL1.2 - Interface Long Haul STM-1 (155Mb) - = 1550nm (aproximandamente 80 Km) ?Mult Modo STM-1 (155Mb) - Curta distncia MM.1 (aproximandamente 2 Km) LEGENDA P4S1N (1) STM-1 - Canal 1 (2) STM-1 - Canal 2 (3) LED BICOLOR:

Vermelho: Falha na unidade Verde: Unidade em Servio

P4E4N (1) 140 / STM-1 / OC-3 - Canal 1 (2) 140 / STM-1 / OC-3 - Canal 2 (3) LED BICOLOR: Vermelho: Falha na unidade Verde: Unidade em Servio A2S1 (1) 140 / STM-1 / OC-3 - Canal 3 (2) 140 / STM-1 / OC-3 - Canal 4 (3) LED BICOLOR: Vermelho: Falha na unidade Verde: Unidade em Servio MDULOS

Eltrico 140Mb e STM-1

ptico STM-1 e STM-4

ptico STM-1 e STM-4

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

ACRONYM P4S4N

SLOTS 25, 26, 28, 29, 34, 35, 37 e 38

LEGENDA (1) STM-4 - Canal 1 (2) STM-4 - Canal 2 (3) LED BICOLOR: Vermelho: Falha na unidade Verde: Unidade em Servio MDULOS IS-4.1, IL-4.1, IL -4.2

ACRONYM A2S4

SLOTS 4 A 19

LEGENDA (1) STM-4 - Canal 3 (2) STM-4 - Canal 4 (3) LED BICOLOR: Vermelho: Falha na unidade Verde: Unidade em Servio MDULOS IS-4.1, IL-4.1, IL -4.2 (uso futuro)

CONECTORES FC/PC SC/PC SFF

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

STM-N STM-1 STM-4

INTERFACES AMPLIFICADORES WAVELENGHT PTICOS PTICAS

L-1.2 JE1 L-4.2 JE L-16.2 JE2

1530 , 1560

BST15

1530 , 1560 BST10, 15, 17 1550 , 1560 BST10, 15, 17 1550 , 1560 BST10, 15, 17 1530 , 1565 BST10

STM-16 L-16.2 JE3 STM-64 L-64.2

BOOSTER MODULE

+
OUT PARA LINHA

WDM coupler

IN VINDO DA PORTA STM

BOOSTER

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

7.2- PLACAS COMUNS:

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

7.3- PLACAS ISA:

7.4- FAN SHELF:

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

7.5- T-BUS:
ACRONYM TBUS SLOTS 42 , 43

(1) LED BICOLOR: Vermelho: Falha na unidade Verde: Unidade em Servio

PLACA ATRS DA PLACA MATRIX

8- APNDICE - Lista de PLACAS:

1660SM TIPO DE PLACA ACRONYM P63E1 P63E1N P63E1N-M4 A21E1 P3E3T3 A3E3 HPROT P4E4N A2S1
MAX QTD SLOTS

63 X 2Mb PORT 21 x 2Mb ACESS 3 x 34 / 45 Mb PORT 3 x 34 / 45 Mb ACCESS HIGH SPEED PROCTECTION ACCESS 4x 140 / STM-1 ACCESS 2x 140 / STM-1 ACCESS

24, 27, 30, 32, 33, 36, 39 1 a 9 e 13 a 21 24 a 39 2 a 9 e 13 a 20 2 a 9 e 13 a 20 24 a 39 2 a 9 e 13 a 20

18 16 16 8 16 16

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

BOARD TYPE
4 x eletrical STM-1 Port 4 x elet. STM-1 Port acess 4 x STM-1 Port 2 x 140 / STM-1 Port acess 4 x OC3 AU3 / TU3 port 1 STM-4 Port 4 x STM-4 Port 2 x STM-4 acess 16 x STM-1 / 4 x STM-4 Port 12 x Optical STM-1 acess 16 x Elet. STM-1 acess

1660SM ACRONYN MAX SLOTS QTD


P4ES1 A4ES1 P4S1N A2S1 P4OC3 S-4.1, L-4.1, L4.2 P4S4N A2S4 P16S1-4E A12OS1E A16ES1E S-16.1 ND L-16.1 ND L16.2 ND I-16.1 ND (**) 16 (**) 8 (**) 16 24 a 39 2 a 8, 13 a 20 2 a 9, 13 a 20 16 16 16 16 16 16 4 24 a 39 2 a 9, 13 a 20 24 a 39 24 a 39 25, 26, 28, 29 34, 35, 37, 38 24 a 39

BOARD TYPE
BOOSTER STM-16 - PREAMPLIFIER

1660SM ACRONYN MAX SLOTS QTD


BST10 - BST15 BST17

8 8

2 a 8, 13 a 19 2 a 8, 13 a 19

PR16

1660SM ACRONYN MAX SLOTS QTD


TBUS EQUICO PQ2 / EQC MATRIXN MATRIXE CONGI 2 (*) 1 (**) 1 (*) 2 (**) 2 2 1 23, 40 22 22 23, 40 23, 40 10, 12 11

4 4 4 (**) 16 4 (**) 4

25, 26, 34, 37 SERVICE 25, 26, 34, 37 25, 26, 34, 37 24 a 39 25, 26, 34, 37 25, 26, 34, 37

STM-16 Port

STM-16 Host Port STM-16 Slim Host Port 4 x Any Host Card STM-64 Port

CO-16 O-16ES 4 x ANYC


S-64.2E I-64.1E

(*) 1660 Rel. 4.4 (**) 1660 Rel. 5.2

BOARD TYPE
ATM Matrix 4x4 ATM Matrix 8x8 Ethernet Port Ethernet Access Gigabit Ethernet Access PR_EA Board PR Port PR Gigabit Ethernet Access PR Fast Ethernet Access

1660SM ACRONYN MAX SLOTS QTD


ATM4X4 - ATM4X4V2 ATM4X4D3

4 4 12 12 8 4 3 6 6

24 a 39 24 a 38 24 a 39 2 a 9, 13 a 20 2 a 9, 13 a 20 24 a 39 24 a 38 2 a 8, 13 a 20 2 a 8, 13 a 20

ATM8x8 ETH-MB ETH-ATX GETH-AG


PREA4ETH PREA1GBE

ISA-PR 2GBA-PR 16FEA-PR

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

ELABORADO POR

ANDR GESTEIRA

9- PROCEDIMENTOS DE MANUTENO: 9-1- Troca de PLACA EQUICO, SYNTH1N, PQ2/EQC, SYNTH16: Para iniciar a Configurao Bsica do equipamento necessrio limpar a base de dados da Equipment Controller (EC) seguindo o Procedimento abaixo: I- Extrair a placa EC; II- Mover as MICRO-SWITCH conforme mostra a figura 2; III- Inserir a placa EC e esperar os LEDs das placas acenderem; IV- Verificar se a base de dados esta LIMPA: todos os slots aparecerem fazios, exeto as placas principais: EC, MATRIX, CONGI e T-BUS; V- Extrair a placa EC e colocar os MICRO-SWITCH nas posies originais: cuidado pois alguns alarmes podem aparecer ao ser inserida a placa no sub.
EQUICO, SYNTH1N PQ2/EQC, SYNTH16
ON OFF 1 2

Condio de operao Normal


Movendo a SWITCH 2 de OFF para ON feito o CLEAN da DB

ON OFF

1 23 4

Figura 1

ON OFF

1 23 4

ON OFF

1 2

Figura 2

PROCEDIMENTO
NOVA UNIDADE: switch#1=OFF e switch#2=ON (reset database) inserir a nova unidade
CONDIO SW e release mesma do NE CONDIO Unidade com SW diferente CONDIO Unidade sem SW CONDIO Unidade com SW errado

Retirar a placa, colocar a switch#1=ON e switch#2=ON e inserir a placa novamente Baixar o SW do NE e executar o procedimento de DOWNLOAD Normal Baixar o SW do NE e executar o procedimento do SIBDL

REMOVER a placa colocar a switch#1=ON e a switch#2=OFF (Posio de reset da base de dados e downloda do BACKUP) Inserir a placa novamente
CONDIO MIB GRAVADA no CRAFT TERMINAL A gerncia envia a MIB salva com as configuraes corretas do NE ATIVADO pela gerncia a MIB envida O CT envia a MIB contendo as configuraes corretas do equipamento ATIVADO pela CT a MIB enviada

REMOVER a placa colocar a switch#1=OFF e a switch#2=OFF (Posio de operao normal) Inserir a placa novamente

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

Consideraes importantes: EQUICO, SYNTH1N OPERACIONAL NORMAL = DEFAUL + OU 2 min RESET MIB 1 OFF OFF ON ON 2 OFF ON OFF ON 3 OFF OFF OFF 4 OFF OFF OFF PQ2/EQC, SYNTH16 1 OFF OFF ON ON 2 OFF ON OFF ON

+ OU - RESET MIB + COPIA DA 2 min LOCAL CONFIGURATION


EXECUTAR O SIBDL FORMATAR A FLASH CARD + DOWNLOAD DO PACOTE

NO OPERACIONAL

TROCA DA EQUICO SEM TROCA DA FLASH CARD: > No necessrio seguir o passo-a-passo, somente colocar a FLASH CARD antiga na placa nova. 9-2- ALARME de INSIDE FAILURE: Ir em Diagnose > Internal Link Monitor:
MATRIXN - r01sr1/board#23 MATRIXN - r01sr1/board#40

P4ES1N - r01sr1/board#24

P4ES1N - r01sr1/board#25

P4ES1N - r01sr1/board#26

MATRIX ACTIVA

GETH-MB - r01sr1/board#28

P16S14E - r01sr1/board#30

P16S1-4E - r01sr1/board#31

S-642E - r01sr1/board#34

S-642E - r01sr1/board#37

EXEMPLOS: CASO1: MATRIXN do slot 23 na principal com um dos links (setas em VERDE) em vermelho, ser necessrio resetar a placa relativa a seta; CASO2: MATRIXN do slot 40 na reserva porem todos os links da mesma esta em vermelho, ser necessrio resetar a placa MATRIXN do slot 40. OBS.: Este alarme no causa perda de trfego, mas em caso de comutaes de placas que esteja alarmadas pode gerar perdas.

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

9-3- ALARME de CPE:

LOS

URU

LOF

URU

TIM

DS

RDI

EBER AIS

SPI
TD TF CSF

RST
PM-AS CSF

MST
CPE PM-AS

MSP

Este alarme significa Erro de Comunicao do Protocolo de COMUTAO, que pode ser resolvido com comutao da placa MATRIXN tanto da estao em que o alarme esta presente quanto na distante. Se ao comutar a MATRIX do equipamento onde o alrme esta presente no sair o alarme, teremos que comutar o da ponta distante. Existem casos onde necessrio at resetar a placa em campo. OBS.: Este alarme no causa perda de trfego, mas em caso de comutao em RING pode gerar perdas de AU-4.

9-3- Forar o LASER:

LOS

URU LOF

URU

TIM

DS

RDI EBER AIS

SPI
TD TF CSF

RST
PM-AS CSF

MST
CPE PM-AS

MSP

Entrar na placa marcar a parte fsica da placa e ir em Port > Phyisical Media > Als Manegement, dentro da caixa se ser aberto, colocar em Als Function:

FORAR O LASER
Forced ON

DESLIGAR O LASER
Forced OFF

REESTABELECER O LASER
Als Enable

OBS.: Foi verificado que em alguns casos de rompimento de fibra, houveram situaes onde para reestabelecer o laser, tivemos que antes de tudo forar o mesmo, dependendo da verso do software do equipamento.

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

9-4- Comutaes MSP-RING:


LOS URU LOF URU TIM DS RDI EBER AIS

SPI
TD TF CSF

RST
PM-AS CSF

MST
CPE PM-AS

MSP

Marcar o Bloco referente a comutao, MSP, ir em Port > MSP > MSP Commands, e na tela que se abrir executar o comando desejado. OBS. IMPORTANTE: PROTECTED - Placa que esta no esquema de proteo como principal, ou seja, PROTEGIDA; PROTECTING - Placa que esta no esquema de proteo como reserva, ou seja, PROTEGENDO. Comandos MANUAIS: Este comando quando h algum tipo de falha na placa de proteo ou principal, o mesmo no comuta; Comandos Forado: Este comando no pode ser esquecido no NE, de extrema importncia, que no seja deixado o equipamento com forado, pois o mesmo, caso haja uma outra falha ele no comutar. Retirar os comandos: Para retirar os comandos basta dar o RELEASE.

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

9-4- Comutaes APS:

Marcar a placa a qual desejamos comutar, ir em EPS > Switch, e ento executar os comandos. Forado, Manual, release, etc. 10- Consideraes finais: Gostaria de informar que esta apostila no esta toda completa, mas qualquer dvida, ns do suporte de Tx, estamos a para tentar responder as questes.

TELEMAR

CGR - CENTRO DE GERNCIA DE REDE - SUPORTE NVEL II TX


TTULO

Solues para voc

NE 1660SM - ALCATEL

DATA

12/07/2006

ELABORADO POR

ANDR GESTEIRA

You might also like