Professional Documents
Culture Documents
TECHNICAL DATA
(Typical values @+25 C for batteries stored for one year or less)
Nominal capacity @ 1 mA, to 2V 1.1 Ah Rated voltage 3.6 V Maximum recommended continuous current 50 mA Maximum pulse current capability 100 mA Weight 9.6 g (0.339 oz) Volume 4 cc Operating temperature range -55 C to +85 C Li metal content approx. 0.35 g U.L. Component Recognition, MH 12193
Volts
4.0
3.5
3.0
2.5
2.0
220 ~14 mA (0.80 Ah) 470 ~7 mA (0.97 Ah) 3.6 k ~1 mA (1.10 Ah) 40 k 220 k 27 k ~0.125 mA ~40 A ~17 A (1.08 Ah) (1.02 Ah) (0.92 Ah)
1.5
SUFFIX- /PT2 RADIAL PINS SUFFIX- /TP POLARIZED TABS SUFFIX- /PT POLARIZED TABS
Volts
3.7 3.5 3.3 3.1 2.9 2.7 2.5 -50
Ah
1.2
-30 C
1.0
25 C
0.8
0.8 mA
0.6
2 mA
55 C 72 C
0.4
7 mA 14 mA
mA
TLL-5902
CELL FEATURES
3.6 V Primary lithium-thionyl chloride (Li-SOCl2) Fast voltage recovery after long term storage and/or usage High energy density High and stable operating voltage Low self discharge rate Bobbin construction Hermetic glass-to-metal-sealing Non-flammable electrolyte
MAIN APPLICATIONS
Utility meters (elect., water & gas) Automatic meter reading RF systems Sensors & monitoring systems Tracking systems Wireless security systems Automotive electronics Industrial electronics Ultra Low Power (ULP)
Volts
3.5 3.4 3.3 3.2 3.1 3.0 2.9 2.8 2.7 0
STORAGE CONDITIONS
Cells should be stored in a clean & dry (less than 30 % RH) area
200
400
600
800
1000
1200 msec
Volts
3.5
VOLTAGE RESPONSE
After 1 year After 5 years
Volts
3.5
VOLTAGE RESPONSE
After 4 years
3.4
3.4
3.3
After 10 years
3.3
After 2 years
3.2
Pulse applied: 10 mA for 100 msec Temperature: RT Background current: 5 A 0 20 40 60 80 100 120 msec
3.2
Pulse applied: 10 mA for 100 msec Temperature: RT Background current: 10 A 0 20 40 60 80 100 120 msec
3.1
3.1