You are on page 1of 5

TS11 TELESERVICE "TELEPHONY" 0- - L/P/S/D

1
0 = not subscribed
1 = subscribed
TS21 TELESERVICE "SHORT MESSAGE MT/PP" 0- - L/P/S/
1 D/R
0 = not subscribed
1 = subscribed
TS22 TELESERVICE "SHORT MESSAGE MO/PP 0- - L/P/S/
1 D/R
0 = not subscribed
1 = subscribed
TS61 TELESERVICE "ALTERNATE SPEECH AND FACSIMILE GROUP 3" 0- - L/P/S/D
1
0 = not subscribed
1 = subscribed
TS62 TELESERVICE "AUTOMATIC FACSIMILE GROUP 3" 0- - L/P/S/D
1
0 = not subscribed
1 = subscribed
TSD1 TELESERVICE "AUXILIARY TELEPHONY" 0- - L/D
1
0 = not subscribed
1 = subscribed
The availability of this parameter value depends on commercial
agreements.
TSMO TRANSFER OF SHORT MESSAGE OPTION 0- - L/S/D
1
0 = transfer of Short Message through the MSC
1 = transfer of Short Message through the Serving GPRS Support
Node (SGSN)
The availability of this parameter value depends on commercial
agreements.
BS21 BEARER SERVICE "DATA CIRCUIT ASYNCHRONOUS 300 b/s" 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
Incompatible with BS2G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
Incompatible with BS2F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
BS22 BEARER SERVICE "DATA CIRCUIT ASYNCHRONOUS 1200 b/s" 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
Incompatible with BS2G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
Incompatible with BS2F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
BS23 BEARER SERVICE "DATA CIRCUIT ASYNCHRONOUS 1200-75 b/s" 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
Incompatible with BS2G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
Incompatible with BS2F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
BS24 BEARER SERVICE "DATA CIRCUIT ASYNCHRONOUS 2400 b/s" 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
Incompatible with BS2G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
Incompatible with BS2F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
BS25 BEARER SERVICE "DATA CIRCUIT ASYNCHRONOUS 4800 b/s" 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
Incompatible with BS2G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
Incompatible with BS2F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
BS26 BEARER SERVICE "DATA CIRCUIT ASYNCHRONOUS 9600 b/s" 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
Incompatible with BS2G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
Incompatible with BS2F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
BS2F FALL-BACK ASYNCHRONOUS BEARER SERVICE 0-
- L/P/S/D
5
0 = No Fall-Back Bearer Service subscribed
1 = The Fall-Back Bearer Service is BS21
2 = The Fall-Back Bearer Service is BS22
3 = The Fall-Back Bearer Service is BS24
4 = The Fall-Back Bearer Service is BS25
5 = The Fall-Back Bearer Service is BS26
The availability of this parameter value depends on commercial
agreements.
Incompatible with BS2x when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero. BS2x refers to any
of BS21, BS22, BS23, BS24, BS25 and BS26.
Incompatible with BS2G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), BS2G value is zero and BS2F value is different from zero.
BS2G GENERAL ASYNCHRONOUS BEARER SERVICE 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
The availability of this parameter value depends on commercial
agreements.
Incompatible with BS2x when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.BS2x refers to any
of BS21, BS22, BS23, BS24, BS25 and BS26.
Incompatible with BS2F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), BS2G value is zero and BS2F value is different from zero.
BS31 BEARER SERVICE "DATA CIRCUIT SYNCHRONOUS 1200 b/s" 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
Incompatible with BS3G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
Incompatible with BS3F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
BS32 BEARER SERVICE "DATA CIRCUIT SYNCHRONOUS 2400 b/s" 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
Incompatible with BS3G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
Incompatible with BS3F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
BS33 BEARER SERVICE "DATA CIRCUIT SYNCHRONOUS 4800 b/s" 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
Incompatible with BS3G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
Incompatible with BS3F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
BS34 BEARER SERVICE "DATA CIRCUIT SYNCHRONOUS 9600 b/s" 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
Incompatible with BS3G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
Incompatible with BS3F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero.
BS3F FALL-BACK SYNCHRONOUS BEARER SERVICE 0-
- L/P/S/D
4
0 = No Fall-Back Bearer Service subscribed
1 = The Fall-Back Bearer Service is BS31
2 = The Fall-Back Bearer Service is BS32
3 = The Fall-Back Bearer Service is BS33
4 = The Fall-Back Bearer Service is BS34
The availability of this parameter value depends on commercial
agreements.
Incompatible with BS3x when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero. BS3x refers to any
of BS31, BS32, BS33 and BS34.
Incompatible with BS3G when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), BS3G value is zero and BS3F value is different from zero.
BS3G GENERAL SYNCHRONOUS BEARER SERVICE 0-
- L/P/S/D
1
0 = not subscribed
1 = subscribed
The availability of this parameter value depends on commercial
agreements.
Incompatible with BS3x when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), and their values are different from zero. BS3x refers to any
of BS31, BS32, BS33 and BS34.
Incompatible with BS3F when both SUD's are entered in
commands HGMCI (parameter NEWSUD) or HGSPC (parameter
SUD), BS3G value is zero and BS3F value is different from zero.
BSL BASIC SELF LOCATION MOBILE ORIGINATING LCS CLASS 0-
- L/D
1
0= not provided
1= provided
The availability of this parameter value depends on commercial
agreements.

You might also like