Flanged Dilution Probe New Product

Flanged Dilution Probe


The Envent Flanged Dilution Probe eliminates problems associated with sampling high H2S concentrations in wet, dirty gas at low pressure. No sample pump required No venting of high H2S sample Highly resistant to contamination Sample is measured insitu at process temperature and pressure No H2S loss in the sample filter Enhanced safety, no exposure to process gas during maintenance No power required (safe in hazardous locations) Isolates the analyzer from the process gas

The Problem Sampling from low pressure process lines can pose problems when conventional sampling techniques are used. Sample pumps require frequent maintenance, coalescing filters may remove H2S as well as contaminants and required maintenance can create unsafe working conditions when high H2S concentrations are analyzed. Process upsets can contaminate the analyzer requiring maintenance and contributing to analyzer downtime. The Solution The Envent Flanged dilutor allows percent level H2S to be safely measured at low or no pressure. The probe completely isolates the analyzer from process contaminants. No regular maintenance is required. The process H2S permeates across a membrane at a controlled rate. The permeable membrane material is selected to be resistant to process contaminants found in natural gas and produced gas. The H2S is picked up by the carrier gas and only the clean dry carrier is transported to the analyzer.

Carrier gas from analyzer 1/8" 316 SS tube

Carrier gas to analyzer 1/8" 316 SS tube

This port plugged

2" 316 SS Full Port Ball Valve

2" 150# 316 SS RF Flange

PROCESS PIPING

BY CUSTOMER

Envent Engineering Ltd. 7060E Farrell Road. S.E., T2H 0T2 Calgary, Alberta, Canada. Telephone +1 403 253 4012 | Fax +1 403 253 4016 | Email info@envent-eng.com

SPECIFICATIONS
Utilities Instrument air at 100 cc/min

Carrier gas from analyzer 1/8" 316 SS tube

Carrier gas to analyzer 1/8" 316 SS tube

This port plugged

Sample Pressure Ambient

0 to 10 psig

0 to 100 C
2" 316 SS Full Port Ball Valve

Dilution Ranges

0 to 1% to 0 to 50% 2 NPT pipe or 2 150# RF flange (others on request)

Process connection Response Time Repeatability

60 seconds to 90% 1.5% of reading Permeable membrane

2" 150# 316 SS RF Flange

Principle of Operation Calibration Maintenance

Integral calibration ports


PROCESS PIPING BY CUSTOMER

Isolation block valve

Envent 331 H2S Analyzer (Division 2 hazardous locations)

Envent 330 H2S Analyzer (Division1 hazardous locations)


Envent Engineering Ltd. 7060E Farrell Road. S.E., T2H 0T2 Calgary, Alberta, Canada. Telephone +1 403 253 4012 | Fax +1 403 253 4016 | Email info@envent-eng.com