Manufacturer: Emergency One Unit No. 1 Manufacturers Model: Pumper 44 (Typhoon) Engine Make: Cummins Model: ISL 400 Pump Make: Hale Model: QMAX150-23 Model Yr.: 2002 Department: Manufacturers Serial No. 123456 BHP 400 at 2200 Stages: 2 Torque: 1200 200 PSI 10 : 1 2.28 : 1 D 1050 My Fire Department VIN: 4EN6AAA8021003456 RPM 2330 Ft Lbs at 1300
Counter Ratio: Gear Ratio: Engine to Pump Transmission Gear Used Test Requirements (in GPM) Run by: Howard Sykes
Tested at: Their Fire Department, Any Street, Durham, NC Date: Air temp: 81 Pressure: 30.15 Water temp: 78 Counter Speed Checked Readings Taken From: Veedee Root 6611 Suction Size: 6 inches Length 16 feet Lift: 3.33 feet 1250 Dry Vacuum test: 8 inch drop in 5 minutes Time to obtain suction: 33 seconds (water flow) Tank flow test: seconds GPM Tip Size: 1.5 Pitot: 58 0 gallons flowed at: 508 Tank flow test: 1.5 Tip size 58 Pitot pressure 700 GPM maximum flow rate measured with a HOSE LAYOUT: Two lines of 2-50 sections + two 1-50 sections 2.5 hose Digital Counter Start Stop 130 131 132 132 134 659 132 8
Engine Counter Pump Speed
Pump Pressure Appar. Gauge Pump Pressure Test Gauge
Tip Size:
2 1/2
Pitot
Suction Pressure
Pitot Reading
81 81 81 81 81
10% Overload test Digital Counter Time 15:42 15:47 Start Stop 138 136
Suction Pressure
Pitot Reading
3146 3101
1380 1360
1374 1373
170 165
162 162
4 4
166 166
81 81
HOSE LAYOUT: Two lines of 2-50 sections + one 1-50 2.5 hose Digital Counter Time 15:56 16:01 16:06 Start Stop 149 142 146
Engine Counter Pump Speed Speed from App. Tach. counter Speed
Pump Pressure Appar. Gauge Pump Pressure Test Gauge
Tip Size:
2 1/8
Net Pump Pressure Pitot Reading
Pitot
Suction Pressure
4 4 4
64 64 64
437 146 15
4439 1480
574 191
594 198
12 4
606 202
192 64
3168 1056
HOSE LAYOUT: Two lines of 2-50 sections 2.5 hose Digital Counter Time 16:15 16:20 16:25 Start Stop 167 167 170
Engine Counter Pump Speed Speed from App. Tach. counter Speed
Pump Pressure Appar. Gauge Pump Pressure Test Gauge
Tip Size:
1 3/4
Net Pump Pressure Pitot Reading
Pitot
Suction Pressure
3 3.5 3.5
68 68 68
504 168 15
4993 1664
763 254
750 250
10 3
760 253
204 68
2250 750
FINAL RESULTS 150 psi 1. 2. 3. 4. 5. 6. 7. 8. 9. Average Nozzle Pressure Gallons Per Minute Pump Stage (Par/Ser) Avg. Pump Press. (App. Gauge) Avg. Pump Press. (Test Gauge) Suction Pressure Average Net Pump Press. Avg. RPM Engine: Counter Avg. RPM Engine: App Tach 81 1506 Volume 150 145 6 151 1318 1327 3005 200 psi 64 1056 Volume 191 198 4 202 1457 1480 3321 250 psi 68 750 Pressure 254 250 3 253 1664 1664 3830
09/14/03 Date
09/14/03
gallon booster tank seconds (water flow) ze: 1.5 Pitot: 58 Pitot pressure 81
REMARKS
crease at 90 psi
REMARKS
64
REMARKS
68
REMARKS
Date of test:
9/14/03
Manufacturer: Emergency One Serial No: 123456 Department: My Fire Department Test location: Their Fire Department, Any Street, Durham, NC Manufacturer's model: Pumper 44 (Typhoon) Engine Mfg: Cummins Model: ISL 400 Pump Mfg: Hale Model: QMAX150-23 Test Conditions: Barometric Pressure: Temperature: 78 30.15 Suction hose size: Hose length: 16 6 Pump inlet elevation above water: 3.33 feet
4000 3500
3000
2500 2000 1500 1000 500 0
150 test 165 test 200 test 250 test GPM 1506 1506 1056 750 PSI 145 162 198 250 Vacuum 6 4 4 3 Net PSI 151 166 202 253 eng. RPM 1318 1370 1457 1680 pump RPM 3005 3124 3321 3830 pump stage Volume Volume Volume Pressure
150 test 165 test 200 test 250 test
Relief valve increase: psi Vacuum test drop: 8 Pump prime time: 33 8 No Load goverened speed: 2330 Tank flow test: Tank size: 1250 gallons; 0 gallons flowed at 508 GPM Tank flow test: Tank size: 1250 gallons; Maximum flow rate is: 700 GPM
secs.