Controls & Switchgear Company Ltd.

Salient Features
n Lightest & compact n High breaking capacity-45/50kA n Thermal magnetic release provides high degree of system protection against OVER LOAD, SHORT CIRCUIT & EARTH FAULT(Optional) n Total breaking time less than 30ms including arcing time of less than 10ms ensures fast acting mechanism n Most simple to operate and maintain n Highest value of mechanical & electrical endurance due to patented mechanism n High dielectric strength even in hot and humid conditions due to use of class 'B' and 'F' insulating material n Fibre glass safety shutter for safety of operating personnel. n Can with stand impulse voltage of 8kV(peak),1.2/50 micro sec wave as per case 'A' in homogeneous field conditions of IEC 947-part1 n Comply with utilization category B & pollution degree 3 group 1 of IEC947-Part1 n Tested for seismic conditions suitability. n Wide range of accessories offeredShunt trip, UVT, Auxiliary Switch, trip indication switches to meet market specifications.

CS "AIR CIRCUIT BREAKERS are available in current range of 630~1600A in a single frame with wide options of accessories-for utmost reliability, safety protection and various applications n 3 Pole n Manually operated Fixed version n Most Reliable and economical Protection release Thermal Magnetic type provides OL, SC and GF (optional) protection. n Bus bar connection-Horizontal

High Breaking Capacity & Large Short - Time Current Capacity


Full utilization of electromagnetic repulsive force Even though it is sound and compact in design, it provides a high breaking capacity and a large short - time current capacity by fully utilizing the electromagnetic repulsive force.

l The contact spring normally provides an adequate contact pressure. l A large current flow causes an electromagnetic repulsive force between the contact lead halves. l This repulsive force works in a direction to turn the moving contact clockwise about the contact shaft, giving it more contact pressure. l This is why our design provides a large short-time current capacity.

Complete Isolation of Poles

l When interrupting a large current, the electromagnetic repulsive force works in a direction to separate the moving contact from the stationary contact. l A separating force resulting from the electromagnetic repulsive force adds to that by the trip spring, assisting a high-speed interruption. This is why our design provides a high breaking capacity

Amperes Frame (based on IEC / IS) Type (3 Poles) Insulation Voltage Ui (V) AC Impulse Voltage Uimp (V) AC (Peak) Dielectric strength (for a minute) kV Rated Breaking Capacity/Rated Making Capacity (Icu=Ics, RMS/Icm, Peak) kA 415V AC Short time current Icw kA for 1 sec. RMS Total breaking time/closing time (m.sec.) Weight (kg) Overall Dimension (H x W x D) (mm)

630 AH-6B 690 8 3

800 AH-8B 690 8 3

1000 AH-10B 690 8 3

1250 AH-12B 690 8 3

1600 AH-16B 690 8 3

45/94.5 45 30/40 40

45*/94.5 45 30/40 40

50/105 50 30/40 42

50/105 50 30/40 42

50/105 50 30/40 44

487 x 332 x 320

Economical Thermal Magnetic Release


l A direct acting electromagnetic instantaneous trip device with fixed current setting for Short Circuit Protection l CT actuated thermal Overload relay offers settings 80-120% used along with Shunt trip for O/L Protection Tripping Characteristics of Thermal Magnetic Trip Device
1.05 1.3

4 hour 3 2 1 50 20 8 6 5 4 3 2 1 50 40 30 20

80% 100% 120%

Long Time Delay Trip Current setting range

minute

Balanced (Cold Start) ------Balanced (Hot Start)

Operating Time

TIME

Accuracy of Time & Current Setting 20% Calibrated at40C:

Magnetic Release will take over at the short circuit setting, tripping the ACB instantaneously.

40ms. 30ms. MAGNETIC INST. S/C TRIP

RATED CURRENT
Current setting of non-adjustable magnetic instantaneous trip
Applicable Breaker AH-6B AH-8B
3 5 7.5 10 15 20

second

10 8.0 6.0 5.0 4.0 3.0 2.0

AH-10B AH-12B AH-16B


5 7.5 10 15 20 25

NI Instantaneous Trip Device

l Select and specify one of the pick-up currents from the table l Tolerance is +20%

200

250 300

400

100 120 125 150

500

600

% Rated Current of Base Current

Note : 1 : Applicable where rated current of overcurrent trip devices is not less than 250A. : 2 : Applicable to AH - 10B and AH - 12B only. : 3 : Default setting for 16B

60 70

80

Outline dimensions and Panel mounting details


H L H L 130 160 120 N 230 220 240 487 23.2 Terminal blocks for control circuits (Left, Right) Screw M4 15 2- 10 mounting holes 12 135 151.5(3P) 184(4p) 166(3p) 199(4p) 151.5(3P) 284(4P) 166(3p) 299(4P)
15 Dust plate Front cover Lifting plate 20 20 100 115 (3p) 254(4p)
N

(3P)

(4P)

87

92 15

5 10.0

45

25

2-11

30 Length for bus bar connection

115 (3p) 154(4p)

487

334 (4P)

397

b 384

360(3P)

74 37

45 85 85 85 (3P) 100 100 100 (4P)

5 12(3P) (MAX.) 50 15(4P) 4-12 Mounting holes

61

259 80

160 DUST PLATE SURFACE

187

TYPE OF ACB AH-6B AH-10B,AH-12B AH-16B

b 107 107 115

t 8 12 20

Controls & Switchgear Company Ltd.


TM

Central Marketin g Office: Tel. : +91-11- 30887520-29 Fax: +91-11-2684 8241, 2684 7342 email : cmo@controlsind ia.com , info@controlsind ia.com
International Business Division: 222,Okhla Industrial Estate, New Delhi - 110020 Tel.: +91-11-41613503, 3088 7520 - 29 F ax:+91-11-26838291, 26848241 email: infoexport@controlsindia.com

W e b s i t e : w w w. c o n t r o l s i n d i a . c o m

CSG/PUB/ACBBTYPE/010607