Professional Documents
Culture Documents
www.meedco.gov.eg
11 .
-:
- :
- -:
)
(
- -:
.
- :
.
-:
www.meedco.gov.eg
:
.
:
-1
220 -500 .
-2
33 - 66 132 .
-3
-4
11 - 22 .
1 .
www.meedco.gov.eg
-:
.
- :
-1
Cost
-:
Fixed Cost
Running Cost
.
) (
.
-2
-3
www.meedco.gov.eg
2-4
2-4-1
2-4-1-1
2-4-1-1-1
2-4-1-1-2
2-4-1-1-3
2-4-1-1-4
2-4-1-1-5
2-4-1-2
2-4-1-2-1
2-4-1-2-2
:
- 1
- 4
- 2
- 5
- 3
- 6
- 7
:
:
:
:
) (
2.5 3
: 30 20
) (
:
:
:
www.meedco.gov.eg
2-4-1-2-3
2-4-1-2-4
2-4-1-2-5
:
...
www.meedco.gov.eg
www.meedco.gov.eg
11 .
**********************************
-1
-2
-3
-4
-5
-6
-7
-1
*
Poles Or Towers
9/12
10/12
3 22 .
1 1.5
2
6 4
12 11 .
1 1.8
2
1
www.meedco.gov.eg
11/12
10/12
11/12
3 4
6 11 .
3 22 .
1 1.8
2
12/15
6 22 .
1
2
13/21
*
5/12
6/12
30
o
1
12
6 3
www.meedco.gov.eg
7/12
60o
7/12
1
12
6 3
6
3 3
3
8/15
2 + 3 .
10
www.meedco.gov.eg
11
www.meedco.gov.eg
Insulator
:
-:
-1
-2
3 )
(
-4
- 5
-6
- :
-1
-2
-3
12
www.meedco.gov.eg
-1 -:
22 .
.
-:
.
" " :
.
- :
-:
.
13
www.meedco.gov.eg
-2 Disc lnsulator -:
11 .
Soket
Ball
22 . .
.
22 .
.
- :
-1 - :
-2 -:
.
.
-3 Flash . Over :
) (
.
14
www.meedco.gov.eg
15
www.meedco.gov.eg
- :
-1
-2
-3
-4
-5
16
www.meedco.gov.eg
17
www.meedco.gov.eg
Conductors
% 99.5
150/25
70/12
95/15
21/ 120
- :
-1 35/6 70/12 2
5 15 .
18
www.meedco.gov.eg
-2 150/25
20 .
19
www.meedco.gov.eg
)
( .
-:
-1
-2
-3
resistance
inductance
capacitnance
leakage
-4
ACSR
-:
-1
.
.
-2
20
-3
-4
) / ( 2
-5
) / 2 (
www.meedco.gov.eg
21
www.meedco.gov.eg
Tension clamp -:
- :
- :
-: 4 3
4 3
.
3 -:
6 3
. u
4 -:
8 4
.
.
-:
3
4
22
6000
9000
www.meedco.gov.eg
-:
.
3
50 2
.
23
www.meedco.gov.eg
24
www.meedco.gov.eg
5 .
-1
.
-2 .
- .......
-:
-1 Vertical mounting switch
-2 Horizontal mounting switch
200
25
400
630
www.meedco.gov.eg
- :
-1
-2
3
.
-3
9 .
-4
-:
-
Operation Handel
- 2
.
-5
-6
:
.
Insulator
Vertical rod
26
Insulator
www.meedco.gov.eg
27
www.meedco.gov.eg
11 / 33 66/11
.
-1 -:
- :
. . -: -1 ) (.
) ( .
-2
-3 ) (
.
-2
-:
-1
-2
.
.
- 3 -:
28
www.meedco.gov.eg
Profiles
.
-4 -:
20
.
-5 Erection of tower -:
-:
.
.
30
20
24
.
29
www.meedco.gov.eg
5/12
"
1.1
1.1
1.9
20
"
6/12
30
"
1.2
1.2
1.9
20
"
7/12
60
"
1.2
1.2
1.9
20
"
7/12
"
"
1.2
1.2
1.9
20
7/12
"
"
1.2
1.2
1.9
20
8/15
"
"
30
1.1
1.1
2.2
20
50
20
50
20
50
20
50
20
50
20
50
20
0.8
3
0.8
3
0.8
3
0.8
3
0.8
3
0.8
3
0.4
0.4
0.4
0.4
0.4
0.4
200
250
250
250
250
250
www.meedco.gov.eg
9/12
"
1.1
1.1
1.9
20
"
10/12
1.2
1.2
1.9
11/12
20
11/12
"
1.2
1.2
1.9
20
"
12/15
1.1
1.1
1.2
1.2
13/21
"
"
31
2.2
2.2
20
20
50
20
50
20
50
20
50
20
50
20
0.8
3
0.8
3
0.8
3
0.8
3
0.8
3
0.4
0.4
0.4
0.4
0.4
200
250
250
250
250
www.meedco.gov.eg
"
"
2-4-1-3
/
2
35/6
50/8
70/12
95/15
120/21
6
6
6
26
26
1
1
1
7
7
2.7
3.2
3.99
2.1
2.45
2.7
3.2
3.99
1.65
1.95
1
/
) (
139
196
302
368
505
1271
1785
2610
3416
4716
-6 Stringing of conductors -:
- :
-1
3 Rollers
Cross Arm
.
32
www.meedco.gov.eg
-2
) (
.
-3
-4
2
.
33
www.meedco.gov.eg
-7 Sagging -:
) ( 6
.
-1
-2
-3
-4
sag
) (
) (
) - (
) (
= =
8
34
www.meedco.gov.eg
-8 Jumpering of -:
conductors
Tie wire
-1 Joint :
-
-2
.
Clamp :
-1
35
www.meedco.gov.eg
-2
) ( .
36
www.meedco.gov.eg
Comparison between main feeders and lateral O . H . L
main feeder
2
2
35/6
150/25
1
70/12
120/21
lateral
2
A 630 200
A
400 A
3
A D.O.F
200
) )
4
(
(
) ( 4
2
=
8
..
.
.
..
)
( .
25 / 150
85
37
www.meedco.gov.eg
12 / 70
100
6 / 35
120
- Leaning of
1
Tower
-
Alligment of Line
2
insulators
- Leaning of
Leaning - Cross
Arm
Up lift of conductor
38
www.meedco.gov.eg
-
5
.
The jumpers are very loose and
near the tower
39
www.meedco.gov.eg
-
6
sufficient
.
7
Right of way
40
www.meedco.gov.eg
41
600
2300
6600
10000
1.07
20000
1.14
22000
1.14
www.meedco.gov.eg
.
11
.
11
-: - :
-1
.
-2
.
-3 .
-4
.
-5
.
-6 ) ( Cross - Arm
.
-7 - :
-
.
- ) (
.
-8
-9
42
:
:
.
www.meedco.gov.eg
-1
-2
-3
43
-4
-5
-6
www.meedco.gov.eg
44
www.meedco.gov.eg
************
Earthing
-:
********************
-:
Types of faults occures in over head lines
-1
-3 2
phase to phase to - 3
-4 3
3 - 4
GROUND
.
45
www.meedco.gov.eg
11 .
-1 :
//2
50
.
-2 :
70 2
14 //2
1
.
1 1
3
.
70 2
46
www.meedco.gov.eg
) (
5
) (
.
47
www.meedco.gov.eg
-3 -:
Temporary Earthing
.
3
50 2
3
.
) (
.
48
www.meedco.gov.eg
49
www.meedco.gov.eg
50
www.meedco.gov.eg
2-3
15
2
60 IP 55
254 2
)
( 15 :12 : 8
:
15 : 12
16
10.
3 3 2
100
4
8
8 6 4 3
5
2
51
www.meedco.gov.eg
25 4 2
300
) 10 - 20 (
150
350
500
750
/
/
/
/
8
8
8
8
90
IP 54
/ 400 / 250
/ /
0.4..
.1
.2
.3
.4
.5
.6
...
2 2.5
52
www.meedco.gov.eg
1
:
0.8
0.4
250
150/8
350/8
500/8
120
50
20
20
20
120
120
60
20
60
20
20
250
50
0.8 0.4 3 3
250
50
0.8 0.4 3 3
250
50
0.8 0.4 3 3
)
) (
90
750 ) ( 8/ 750
500 ) ( 8 / 500
500 ) / 500
(8
53
www.meedco.gov.eg
3
:
)
(
30
5 )
... (
:
35 2
16 2 )
(
% 7.5 220
204 236
39 45
:
) (
)
(
) (
28 27
-:
54
www.meedco.gov.eg
5
3.5
1.5
1
26
26
2
2.5
100 2
100
.1
.2
1.25
.3
2 1
55
www.meedco.gov.eg
.1
.2
2
.3
.1
.2 )
(
1
-1
-2
-3
-4
6
66 - 22. .
6 11
. .
66 - 33. .
3
11. .
2
-:
) (
4 10
4 10 410 5
4 10 5 10
410
4 10 10
-5
56
) (
20
30
40
60
-:
5 66 33
. . 1000
4 11. .
1000
-:
2.5 .1
11..
4 .2
33..
www.meedco.gov.eg
-6
5 .3
66..
)
(
35
2
1.25
380/220
1.25
-:
1 ) (
.1
2
.2
5
.3
1
.4
2
1
.1
5 25
.2
2
5
-:
.1
.2
1.5
.1
5
.2
1.5
10
57
www.meedco.gov.eg
16
25
35
50
70
2
2
.1
.2
.3
.4
.5
.6
.7
.8
.9
.
.
24
24
50 20
5
3
3
3
3
3
3
58
35 + 70
50 + 95
2
70 + 120
2
70 + 150
2
95 + 185
2
120 + 240
2
www.meedco.gov.eg
16 2 + 25 3
25 2 + 35 3
35 2 + 50 3
3 25 2 R - S - T
+ 2 16 2
3 35 2 R - S - T
+ 2 25 2
3 50 2 R - S - T
+ 2 35 2
3 70 2 R - S - T
+ 2 50 2
50 2 + 70 3
.1 3 16 19 150/8
.2 4 16 19 8/ 350
.3 6 16 19 8 /500
.1 8 16
.2 10 35
.3 14 70 50
59