8385 Tera Data Initial WT and Design Report

IN - BUILDING SOLUTION
8385 Tera Data Initial WT and design Report

SITE NAME

Tera Data

SITE ID
Contact Person
DESIGN BY
CHECKED BY
APROVED BY
DESIGN DATE

8385
Ehmar Yaar
Taufique Ahmed

Latitude:
SITE
ADDRESS

CONTACT INFO
CONTACT INFO
CONTACT INFO
CONTACT INFO
23-02-2013
APPROVED DATE
Coordinate (GPS)
33.682765N
Longitude:

Confidential
0300-5175628
0345-5228128

73.041294E

Tera Data T.F Complex G-9/4 Islamabad

1|P a g e

8385 Tera Data Initial WT and Design Report

Contents
1

System Overview ................................................................................................................. 4


1.1

Building Description and Location ......................................................................................... 4

1.2

System Introduction ................................................................................................................ 5

1.3

System Expansion ................................................................................................................... 5

1.4

DBS Information 3900 ............................................................................................................ 5

Design Principle.................................................................................................................... 6

Signal Leakage Analysis ..................................................................................................... 7

Design Objective .................................................................................................................. 7

Coverage Requirements ..................................................................................................... 8

System / Schematic Diagram ............................................................................................. 9

Antenna Location and Cable Routing ............................................................................. 10

EIRP Table .......................................................................................................................... 15

Material List ......................................................................................................................... 16

10

Pre-Walk Test Report ........................................................................................................ 17


10.1.1

10.2

10.2.1
10.2.2
10.2.3

10.3

Event Statistics ....................................................................................................................... 25


Idle GSM RxLev Sub(dBm) .................................................................................................. 26
BCCH Idle Mode .................................................................................................................... 27

1st Floor Dedicated Mode ................................................................................................. 28


10.5.1
10.5.2
10.5.3
10.5.4
10.5.5

10.6

Event Statistics dedicated mode ......................................................................................... 20


Dedicated GSM FER Sub (%) ............................................................................................. 21
Dedicated GSM RxLev Sub(dBm) ...................................................................................... 22
Dedicated GSM RxQul Sub.................................................................................................. 23
BCCH Dedicated Mode......................................................................................................... 24

1st Floor Idle Mode ........................................................................................................... 25


10.4.1
10.4.2
10.4.3

10.5

Event Statistics ....................................................................................................................... 17


Idle GSM RxLev Sub(dBm) .................................................................................................. 18
BCCH Idle Mode .................................................................................................................... 19

Ground Floor Dedicated Mode ......................................................................................... 20


10.3.1
10.3.2
10.3.3
10.3.4
10.3.5

10.4

Basement Idle Mode ............................................................................................................. 17

Ground Floor Idle Mode ................................................................................................... 17

Event Statistics dedicated mode ......................................................................................... 28


Dedicated GSM FER Sub (%) ............................................................................................. 29
Dedicated GSM RxLev Sub(dBm) ...................................................................................... 30
Dedicated GSM RxQul Sub.................................................................................................. 31
BCCH Dedicated Mode......................................................................................................... 32

2nd Floor Idle Mode .......................................................................................................... 33


10.6.1
10.6.2

Event Statistics ....................................................................................................................... 33


Idle GSM RxLev Sub(dBm) .................................................................................................. 34
2|P ag e

8385 Tera Data Initial WT and Design Report


10.6.3

10.7

10.7.1
10.7.2
10.7.3
10.7.4
10.7.5

10.8

Event Statistics ....................................................................................................................... 41


Idle GSM RxLev Sub(dBm) .................................................................................................. 42
BCCH Idle Mode .................................................................................................................... 43

3rd Floor Dedicated Mode ................................................................................................. 44


10.9.1
10.9.2
10.9.3
10.9.4
10.9.5

11

Event Statistics dedicated mode ......................................................................................... 36


Dedicated GSM FER Sub (%) ............................................................................................. 37
Dedicated GSM RxLev Sub(dBm) ...................................................................................... 38
Dedicated GSM RxQul Sub.................................................................................................. 39
BCCH Dedicated Mode......................................................................................................... 40

3rd Floor Idle Mode ........................................................................................................... 41


10.8.1
10.8.2
10.8.3

10.9

BCCH Idle Mode .................................................................................................................... 35

2nd Floor Dedicated Mode ................................................................................................ 36

Event Statistics dedicated mode ......................................................................................... 44


Dedicated GSM FER Sub (%) ............................................................................................. 45
Dedicated GSM RxLev Sub(dBm) ...................................................................................... 46
Dedicated GSM RxQul Sub.................................................................................................. 47
BCCH Dedicated Mode......................................................................................................... 48

Product Catalogue ............................................................................................................. 49

3|P ag e

8385 Tera Data Initial WT and Design Report

1 System Overview

1.1

Building Description and Location

Building Name
Building Height (m)
Number of Floors
Building Type
Floor Usage
Coordinates
Targeted Coverage area
Building Condition (0 to 5)

Tera Data T.F Complex


20m
4
Office
Office
33.682765N and 73.041294E
st
nd
rd
Basement, Ground, 1 , 2 and 3 Floors
5/5

4|P ag e

8385 Tera Data Initial WT and Design Report

1.2

System Introduction

Site Type
Band
Sector
# of Antenna/Sector
Antenna Type
(Omni/Directional)
Feeder type
Feeder Length (m)
Antenna Band
DBS Model / 10W
DBS Configuration

1.3

Indoor Micro
1
13

1800 MHz
2
N/A

Omni/Directional

N/A

600m

7/8
N/A

S02

3
N/A

1
N/A

2100MHz
2
N/A

3
N/A

N/A

N/A

N/A

N/A

N/A
N/A
806-2500MHz
3900

7/8
N/A

1
N/A

N/A

System Expansion

Following the lower power more antennas model, deployed system can be reused for 3G
network with minor modifications in the backbone.

1.4

DBS Information 3900




A single BTS3900 cabinet holds up to 2 TRXs. It performs the functions such as Transmit
diversity, 4-way receive diversity.
The BTS3900 cabinet has large power and large capacity. It is small and easy to install
and saves the cost on the equipment room. Especially, it uses the direct air cooling
technology, which saves the cost on the heat exchanger, power consumption, and
Maintenance AC inputs and DC inputs 110 V AC (dual live wires) and 220 V AC 48 V
DC. DC battery power supply
The BTS3900 has strong environment adaptability. It can work under the Temperature of
40Cto +55C. It supports the outdoor application with IP55 protection level.

5|P ag e

8385 Tera Data Initial WT and Design Report

2 Design Principle

In the system designs for GSM1800 network, the EIRP of the indoor Omni Antenna for GSM1800 is
from 5dBm to 10dBm.The coverage distance is about 15 to 20m, this depends on the indoor structure
Link budget for the antennas coverage distance is shown below:
 The in-building aerial transmission loss is calculated as follows:
Ld=32.4+20lgD(Km) + 20lgF(MHz)
D = distance from the antenna to the mobile station (Km)
F = carrier frequency (MHz)


The total path loss is as follows:


L=Ls+LdLr
Ls = loss led by the internal obstruction.
Lr = loss led by the internal estimate.

The minimum in-building coverage field strength is:


Emin = P - L
P means the antenna output power

The aerial transmission loss of different distance is as follows:


As to the GSM1800 system:
PL(dB) =32.45+20lg(1800)+20lgd(km)= 97.5+20lgd(km)
D

1m

10m

20m

25m

30m

35m

40m

Ls

37

57

63

65

67

68

69

For In-building signal, formula is as follow:


L=LD+10LgD (m) + Lr
Lr experienced values are as follows:
1800MHz
Wood Board
Glass
Brick Wall
Concrete Wall
Elevators

68dB
810dB
1416dB
20-25dB
35-40dB

Supposed
The output power of the antennas for GSM1800 P0=7dBm
The gain of omni antenna G0=5dBi, the FAF of the wall is about 20dB,
L (20m) = 63+10lgD (m) +FAF
= 63+13+20=96
So the RSSI=P0+G0-L=7+5-96=-84 (dBm)
So the design of the GSM1800 system can satisfy the systems requirements.

6|P ag e

8385 Tera Data Initial WT and Design Report

3 Signal Leakage Analysis


Indoor signal leakage is mainly caused by the antenna signal leakage in the lower parts of building, if
the building is higher, the route loss will be larger, if the lower building antenna can meet the level
leakage index, and then the high building antenna can also meet the level leakage index. The
antenna to cover the elevator can be installed in the elevator shaft, as the walls of the elevator shift
will absorb the signal, and there will be very little leakage in this area, a sample will be taken from the
ceiling mounted antenna installed on the first floor to analyze the leakage of the signal.
The Lower Floors leakage Analysis (Ground Floor):
Now we count the signal field intensity in the distance of 20m (leakage outside 10m away)
Work out the deviation of path loss between D1 and D2 according to the path loss Formula:
LD1- D2 =20log20/10=6.0dB
The result from above analysis adds glasses loss of windows 6dB, so the path loss is 12dB from the
edge field to outside 10m away.
Even though the signal of GSM close to the edge of windows can reach to -80.0dBm and the signal
field intensity of leakage outside 10m away is under -92.0dBm,it can satisfy the level requirement(90.0dBm).

4 Design Objective
Principle of the In-building Coverage System
 The relative international standard about GSM900/1800 system
 The electro-magnetic protection requirements of the radio Management authorities in
PAKISTAN.
 Other laws and regulations of PAKISTAN.
 Inspection material and testing data on site.

7|P ag e

8385 Tera Data Initial WT and Design Report

5 Coverage Requirements
Design Technical Indexes of GSM System
2G System KPI
RSSI

Floor: RxLev at edge -85dBm

Coverage Probability

Elevator and Basement : RxLev -90dBm


95% coverage area meets the RSSI requirements

Call Quality

More than 95% coverage areas meet the requirements of


RxQual < 4.

EiRP of Indoor
antenna

Floor antenna EiRP: < 12 dBm/carrier


Elevator antenna EiRP: 2 to 6 dBm/carrier (In case of
Elevator coverage)
At a distance of 10m from building RSSI of indoor cell
should be 15 to 20dB less then RSSI of outdoor cell.

Leakage
Handover




The smooth handover between the indoor cell and outdoor


cell should be ensured

The voice traffic of mobile user when busy is set as 0.02Erl.


The call loss rate of wireless channels is set as follows:
 The call loss rate of TCH is 2%
 The call loss rate of SDCCH is 0.1%
GSM interference protection ratio is as follows:
 Co-channel interference protection ratio:
C/I 12dBwithout hopping frequency
C/I 9dBwith hopping frequency
 Adjacent channel interference protection ratio:
200 KHz adjacent channel interference protection ratio: C/I -6dB
400 KHz adjacent channel interference protection ratio: C/I -38dB
The voice quality score of the indoor coverage system is above 96. The score is
calculated by the weighted averages method :
( level 0level 1level 2) 1 + (level 3level 4) 0.8 + (level 5level 6) x 0.5level 70.2
Here level 0 means the sample points with the voice quality 0 covers the total sample points.

8|P ag e

8385 Tera Data Initial WT and Design Report

6 System / Schematic Diagram

9|P ag e

8385 Tera Data Initial WT and Design Report

7 Antenna Location and Cable Routing

10 | P a g e

8385 Tera Data Initial WT and Design Report

11 | P a g e

8385 Tera Data Initial WT and Design Report

12 | P a g e

8385 Tera Data Initial WT and Design Report

13 | P a g e

8385 Tera Data Initial WT and Design Report

14 | P a g e

8385 Tera Data Initial WT and Design Report

8 EIRP Table

15 | P a g e

8385 Tera Data Initial WT and Design Report

9 Material List

NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33

Hardware Equipments
Item
Type
BTS
DBS 3900
UPS
APM30
Splitter(2 way)
PS-N2-N50M
Splitter(3 way)
PS-N3-N50M
Splitter(4 way)
PS-N3-N50M
5dB Coupler
DC-N05-N200C
7dB Coupler
DC-N7-N200C
10dB Coupler
DC-N10-N200C
15dB Coupler
DC-N15-N200C
Hybrid Coupler
HC-M-N200L
Ceiling mounted Omni antenna
IXD-360V03N0
Wall mounted Panel antenna
IWH-090V08N0
N-Male Termination Load
50W / 200W
Cable tie
SGR-FSZD
Jumper Cable
JP-NM/NF3M-1/2
Jumper Cable
JP-NM/NF1M-1/2
Feeder cable(1/2)
CL-1/2
Feeder cable(7/8)
CL-7/8
Connector(1/2)
CN-NM-1/2
Connector(7/8)
CN-NM-7/8
Female-Female connector
NKK
Male-Male connector
NJJ
Male-Female connector
NJK
Insulating Tape
SGR-DGJD
Water Proof Tape Black Color
1 inch 8 m length
Grounding line
SGR-DX-16
Grounding connector
SGR-JDDZ
Grounding connector for & 7/8
SGR-JDDZ
feeder cable
Power wire
16mm
PVC Pipe
1
PVC Pipe
1.5
PVC Clumps
1 inch
PVC Pipe Bolt + Plug
1 inch

Unit
Pcs
Pcs
Pcs
Pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
Volume
pcs
pcs
m
m
pcs
pcs
pcs
pcs
pcs
Volume
Volume
m
pcs

QTY
1
1
3
2
0
2
1
3
0
0
11
2
1
6
6
4
600
0
56
0
6
6
6
8
8
10
6

Remark
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI

Pcs

HUAWEI

m
m
m
Pcs
Pcs

10
600
0
350
350

HUAWEI
HUAWEI
HUAWEI
HUAWEI
HUAWEI

16 | P a g e

8385 Tera Data Initial WT and Design Report

10 Pre-Walk Test Report

10.1 Basement Idle Mode


No Coverage in Basement Area.

10.2 Ground Floor Idle Mode


10.2.1 Event Statistics

17 | P a g e

8385 Tera Data Initial WT and Design Report

10.2.2 Idle GSM RxLev Sub(dBm)

18 | P a g e

8385 Tera Data Initial WT and Design Report

10.2.3 BCCH Idle Mode

120000
100000
80000

18180
22054

60000

28004
40000

28060

20000
0
54

57

59

60

19 | P a g e

8385 Tera Data Initial WT and Design Report

10.3 Ground Floor Dedicated Mode


10.3.1 Event Statistics dedicated mode

20 | P a g e

8385 Tera Data Initial WT and Design Report

10.3.2 Dedicated GSM FER Sub (%)

21 | P a g e

8385 Tera Data Initial WT and Design Report

10.3.3 Dedicated GSM RxLev Sub(dBm)

22 | P a g e

8385 Tera Data Initial WT and Design Report

10.3.4 Dedicated GSM RxQul Sub

23 | P a g e

8385 Tera Data Initial WT and Design Report

10.3.5 BCCH Dedicated Mode

100000
90000
80000
70000
60000
50000
40000
30000
20000
10000
0

22054
28060

57

59

24 | P a g e

8385 Tera Data Initial WT and Design Report

10.4 1st Floor Idle Mode


10.4.1 Event Statistics

25 | P a g e

8385 Tera Data Initial WT and Design Report

10.4.2 Idle GSM RxLev Sub(dBm)

26 | P a g e

8385 Tera Data Initial WT and Design Report

10.4.3 BCCH Idle Mode

30000
25000
20000

10842
22054

15000

28004
10000

38004

5000
0
55

59

60

74

27 | P a g e

8385 Tera Data Initial WT and Design Report

10.5 1st Floor Dedicated Mode


10.5.1 Event Statistics dedicated mode

28 | P a g e

8385 Tera Data Initial WT and Design Report

10.5.2 Dedicated GSM FER Sub (%)

29 | P a g e

8385 Tera Data Initial WT and Design Report

10.5.3 Dedicated GSM RxLev Sub(dBm)

30 | P a g e

8385 Tera Data Initial WT and Design Report

10.5.4 Dedicated GSM RxQul Sub

31 | P a g e

8385 Tera Data Initial WT and Design Report

10.5.5 BCCH Dedicated Mode

90000
80000
70000
60000
22054

50000

28004

40000

38004

30000
20000
10000
0
55

59

60

32 | P a g e

8385 Tera Data Initial WT and Design Report

10.6 2nd Floor Idle Mode


10.6.1 Event Statistics

33 | P a g e

8385 Tera Data Initial WT and Design Report

10.6.2 Idle GSM RxLev Sub(dBm)

34 | P a g e

8385 Tera Data Initial WT and Design Report

10.6.3 BCCH Idle Mode

80000
70000
60000
18037

50000

22054
40000

28060

30000

32068

20000

38004

10000
0
51

55

57

59

61

35 | P a g e

8385 Tera Data Initial WT and Design Report

10.7 2nd Floor Dedicated Mode


10.7.1 Event Statistics dedicated mode

36 | P a g e

8385 Tera Data Initial WT and Design Report

10.7.2 Dedicated GSM FER Sub (%)

37 | P a g e

8385 Tera Data Initial WT and Design Report

10.7.3 Dedicated GSM RxLev Sub(dBm)

38 | P a g e

8385 Tera Data Initial WT and Design Report

10.7.4 Dedicated GSM RxQul Sub

39 | P a g e

8385 Tera Data Initial WT and Design Report

10.7.5 BCCH Dedicated Mode

80000
70000
60000
10842

50000

18180
40000

22054

30000

28004

20000

28060

10000
0
54

57

59

60

74

40 | P a g e

8385 Tera Data Initial WT and Design Report

10.8 3rd Floor Idle Mode


10.8.1 Event Statistics

41 | P a g e

8385 Tera Data Initial WT and Design Report

10.8.2 Idle GSM RxLev Sub(dBm)

42 | P a g e

8385 Tera Data Initial WT and Design Report

10.8.3 BCCH Idle Mode

60000
50000
40000
28004
30000

28113

20000

32068

10000
0
52

60

61

43 | P a g e

8385 Tera Data Initial WT and Design Report

10.9 3rd Floor Dedicated Mode


10.9.1 Event Statistics dedicated mode

44 | P a g e

8385 Tera Data Initial WT and Design Report

10.9.2 Dedicated GSM FER Sub (%)

45 | P a g e

8385 Tera Data Initial WT and Design Report

10.9.3 Dedicated GSM RxLev Sub(dBm)

46 | P a g e

8385 Tera Data Initial WT and Design Report

10.9.4 Dedicated GSM RxQul Sub

47 | P a g e

8385 Tera Data Initial WT and Design Report

10.9.5 BCCH Dedicated Mode

90000
80000
70000
60000
18877

50000

28004

40000

28060

30000
20000
10000
0
44

57

60

48 | P a g e

8385 Tera Data Initial WT and Design Report

11 Product Catalogue

49 | P a g e

8385 Tera Data Initial WT and Design Report

50 | P a g e

8385 Tera Data Initial WT and Design Report

51 | P a g e

8385 Tera Data Initial WT and Design Report

52 | P a g e

8385 Tera Data Initial WT and Design Report

53 | P a g e

8385 Tera Data Initial WT and Design Report


Feeder Cables

54 | P a g e