Cingular UMTS Network Arch & Markets Detailed Design Process Overview About the NDER Questionnaire Pre-requisites for Detailed Design start Design Outputs CNDD Sections Backup
MF CAMA
BMD GMLC
GSM-MSC
MAP CAP
FTP data
OMC-CN
MAP
EMS
LEC/IXC
ISUP
OMC-UPS
GGSN 3G SGSN
VMS
Voice Mail
TDM
pMGW
LMRS
IP signal bearer
3G-MSC
CWS Lucent
RNC
Node B
Nov-05 May-06 May-06 May-06 May-06 Aug-06 Aug-06 Aug-06 Oct-06 Oct-06 Oct-06 Jun-06 Jun-06 Jun-06 Jun-06 Jun-06 Jun-06 Jun-06 Jun-06 Jun-06 Jun-06
1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1
1 1
1 1 1
5 2 3 1 2 2 2 1 1 1 1 1 1 1 2 1 1 2 2 1 3 2
634
664
1328
1578
400 338 64 58 45 53 151 146 42 330 62 146 192 263 45 278 146
1 1 1 1 1 1
1 1 1 1
1 1 2 1
Minneapolis
Rochelle Park Toledo Cleveland Wilkes-Barre Akron Allentown Harrisburg Columbus Norristown Cincinnati
Tucson
Customer
HLD
Design details
(NDP Templates)
Procedures
Implementation Teams
The Design service is delivered by the Wireless Network Design team (L. Johnson Dept.)
*Customer signoff
Lucent Technologies Proprietary Use pursuant to company instruction 6
Darlene Shaw
Collection
CINGULAR
~ 2 weeks
Provide detailed requirements via NDER * Sign off on * NDER (Detailed Design Q) *
Kickoff Detailed Design meeting Review NDER responses Product documentation Generate IP, ATM, MSC, SGSN & UTRAN NDP data Complete Detailed Design Document (CNDD)
Review CNDD
~ 1 week
LUCENT
Network architecture
RF Design
Integration start
* UTRAN NDP scripts may be delivered in 2 iterations: 1 with just Toy cells & the next batch with the launch NodeBs Lucent Technologies Proprietary 9 Use pursuant to company instruction
NDP flow
Cell to RNC Homing (CW) NDER NW Design (CW)
10
NDER Overview
The NDER (Network Design & Engineering Requirements) is an MS-Excel based questionnaire used to collect data on: Topology of the Network Market-specific UMTS parameters that need to be provisioned in the various Network Elements The NDER is completed by the Cingular Market teams involved in the planning, design, integration, provisioning and operations of the new UMTS equipment (& market) The completed questionnaire acts as one of the key inputs for the Lucent Network Design engineers working on the design for that specific market
Lucent Technologies Proprietary Use pursuant to company instruction 11
NDER Layout
General/Misc sections:
Coversheet Document Revision History NDER Instructions Timeline Lucent & Cingular Contact List Action Item Register NDER Sign-off 3GPP Reference Architecture
12
13
- NDP files:
NodeB Area Plan IP Design ATM Transport design SGSN (Packet) Core CS (including uMGW NDP) UTRAN
14
CNDD Sections
Executive Summary Network Design Inputs Network Overview ATM Design UTRAN Design Also includes physical Core Packet Design equipment descriptions Core Circuit Design IP Design Signaling Design Regulatory Services OA&M design Appendix (with all NDPs)
for an example of a CNDD document, visit http://quickplace.web.lucent.com/cing2005, Click on Baseline
Lucent Technologies Proprietary Use pursuant to company instruction 15
Backup Material
16
17
18
Cingular provides:
- Cingular equip side of the LGX, RJ45,
DSX patch panel and/or DACS assignments - Cingular Element Id - Slot, Port #
Sample Phy Conn table
19
20
TP 11 TP9 CP5
1
Disk
5
Disk
7
Disk
F OU N D R Y
N ET W O R KS
Netiron 1500
BZGMR BZGMR BZGMR BZGMR BZGMR BZGMR BZGMR BZGMR
SG Application
BZGMR
BZGMR
100/1000 Ethernet 2
Alarm Card
Alarm Card
Alarm Card
Alarm Card
ATM
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
4 T1/E1 2 2 GP
ATM
Active
Active
Active
Active
Active
Active
Active
Active
Pwr
Pwr
Pwr
Pwr
Pwr
Pwr
Pwr
Pwr
TP 12 10 TP CP 6
TP 16 14 TP CP 8
2
Disk Alarm Card
4
Disk Alarm Card
6
Disk Alarm Card
8
Disk Alarm Card
t gm M
t gm M
t gm M
t m g M
t m g M
t m g M
AP
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
SGSN Cabinet
1000Base-SX
SGSN Router
21
3G MSC layout
CBU
Call Server
LMRS
22