You are on page 1of 4

NEW PRODUCT ANNOUNCEMENT

Universal Power Distribution Unit


For Single and Dual Band Tower Mounted Amplifiers
Designed for the highest reliability even under extreme operating conditions
The PDU is part of the Andrew OneBaseTM Andrew Corporation is optimized for TMA platform, a complete range of operation with Andrew single or dual superior TMA products incorporating state-of-the-art technology and efficient band tower mounted amplifiers. production methods. Housed in a compact The power distribution unit (PDU) provides rack-mountable package, the PDU is power supply for up to six tower mounted engineered to ensure the highest reliability amplifiers (TMA) via the RF feeder and a in demanding environments and is tolerant bias tee at the base station level. to extreme supply and load conditions. The unit is easily and quickly installed in various types of base stations and provides The PDU can be ordered as a kit, including a standard set of cables. the following functions: Wide range DC input voltage range Voltage regulation, ensuring a clean of 20 to 60 Vdc and stable supply is delivered to the TMA with improved power efficiency; Active overload protection provides automatic recovery from transient Current monitoring, providing fault fault conditions on the outputs detection on each output for the TMA and supply path; Alarm reporting, visual for easy on-site troubleshooting as well as an interface for remote alarm indication. Lightning protection provided by circuitry on each input and output

This power distribution unit from

One Company. A World of Solutions.

SPECIFICATIONS

Power Distribution Unit Product Specifications


Application Part number . . . . . . . . . . . . . . . . . . . . . . . . . . . .D54G01P82

Number of outputs . . . . . . . . . . . . . . . . . . . . . . . . 6 Load per output . . . . . . . . . . . . . . . . . . . . . . . . . .Single or Dual LNA Nominal supply voltage, Vdc Electrical Input voltage, Vdc . . . . . . . . . . . . . . . . . . . . . . . .20 to 60 . . . . . . . . . . . . . . . .+24 or -48

Maximum input current, A . . . . . . . . . . . . . . . . . . .4 Output voltage, Vdc . . . . . . . . . . . . . . . . . . . . . . .12 Nominal current per output, mA . . . . . . . . . . . . . .120/250 Maximum total output current, A . . . . . . . . . . . . . .2.2 Monitoring and control Input voltage indicator . . . . . . . . . . . . . .Green LED . . . . . . .Ok . . . . . . . . . . . . . .Red LED . . . . . . . .Failure DC/DC converter indicator . . . . . . . . . . . . . .Green LED . . . . . . .Ok . . . . . . . . . . . . . .Red LED . . . . . . . .Failure TMA status indicator . . . . . . . . . . . . . .Green LED . . . . . . .Ok . . . . . . . . . . . . . .Red LED . . . . . . . .Failure Enable/disable TMA outputs . . . . . . . . . . . . .Dip-switch for each output Enable/disable/Reset TMA alarm . . . . . . . . . . .Dip-switch for each output Summary alarm output . . . . . . . . . . . . . . . .Relay contact; normally . . . . . . . . . . . . . . . . . . . . . . . . . . .open and normally closed . . . . . . . . . . . . . . . . . . . . . . . . . . .available High/Low current mode ........ . . . . . . . . . . . .Jumper Selectable Mechanical Height, depth, width, mm (in) . . . . . . . . . . . .44 x 125 x 483 . . . . . . . . . . . . . . . . . .(1.75 x 4.9 x 19) Weight - without mounting hw, kg (Ib) . . . . . . . . . . . .1.1 (2.4) Finish Mounting Rack mounting Grounding Ground terminal, mm (in) . . . . . . . . . . . .Light gray Bias tee harness Part number . Cable type . . Length, m (ft) Pigtails, m (ft) Termination . . . . . . . . . . . . . . . . . . . . . .C61L01P01 .6 x RG174-A/U .6 (20) .0.5 (1.5) .6 x SMA-m Alarm cable Part number . Cable type . . Length, m (ft) Termination . . . . . . . . . . . . . . . . . .C61B01P31 .3 x 24 AWG .7 (23) .Solder pins Environmental Operating temperature range . . . . . . . . . . . .-10 C to +60 C Storage temperature range Ingress protection Lightning protection . . . . . . . . . . . .-40 C to +85 C . . . . . . . . . . . .IP20 . . . . . . . . . . . .IEC 801-5

Accessories Power supply cable Part number . Cable type . . Length, m (ft) Termination . . . . . . . . . . . . . . . . . .C61B01P32 .2 x 24 AWG .5 (16) .Solder pins

. . . . . . . . . . . .19 EIA, 1RU

. . . . . . . . . . . .6 (1/4) dia

SPECIFICATIONS

Power Distribution Unit Product Specifications

Block Diagram

Mechanical Drawings

SPECIFICATIONS

Power Distribution Unit Ordering information

PDU part no. D54G01P82 D54G01P83

Description Universal PDU Universal PDU with cables

Supply voltage +24 Vdc or -48 Vdc +24 Vdc or -48 Vdc

Cable set Not Included Included

Notes: 1. Each cable set includes: power supply cable, alarm cable, and bias tee harness

One Company. A World of Solutions.


Andrew Corporation
10500 W. 153rd Street Orland Park, IL 60462 USA

Customer Support Center


From North America Telephone: 1-800-255-1479 Fax: 1-800-349-5444 International Telephone: +1-708-873-2307 Fax: +1-708-349-5444 Internet: www.andrew.com

Forem Srl
An Andrew Company Via Archimede 22/24 20041 Agrate Brianza, Italy Phone +39 039 60541 Fax: +39 039 6054477

All designs, specifications and availabilities of products and services presented in this bulletin are subject to change without notice. Bulletin PA-100406-EN (03/07) 2007 Andrew Corporation, Orland Park, IL 60462 USA