AN-80i

Advanced Broadband Wireless Infrastructure Solutions

Quick Install Guide


1 Safety Notices
1. Do not exceed the described limits on product labels. Position power cords to avoid

damage. Do not overload wall outlets. Protect equipment by disconnecting power when not in use. 2. Do not place PoE power adaptor on or near a direct heat source or operate near water or in a wet location. Disconnect the PoE power before cleaning and use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners. 3. The AN-80i unit must not be located near power lines or other electrical power circuits. 4. The AN-80i must be properly grounded to protect against power surges and accumulated static electricity. It is the user's responsibility to install this device in accordance with the local electrical codes and building codes: grounding of the transceiver unit, mast, lead-in wire and discharge unit, location of discharge unit, size of grounding conductors and connection requirements for grounding electrodes.

Important Service Information


1. Refer all repairs to qualified service personnel. Do not remove the covers or modify any

part of this device, as this voids the warranty.


2. Locate the serial numbers and record these on your registration card for future

reference. Record the MAC address located on the AN-80i.

AN-80i User Documentation


The RDL-3000 system user manuals are available online at Redline Partner support portal. If you can not access the Redline support portal directly, contact your Redline partner or sales representative to obtain electronic copies of the RDL-3000 system documentation (Adobe PDF format).

70-00074-01-08

Proprietary Redline Communications 2011

Page 1 of 8

March 15, 2011

AN-80i

Installation Guidelines

Test Overview
This Quick Install Guide provides steps for basic configuration and operational testing of an AN-80i PTP link. This procedure assumes a setup consisting of two complete AN-80i units. Refer to the AN-80i User Manual and Installation Guidelines for additional safety instructions and for specific operational and installation details.

4.1
1. 2.

Required Test Facilities


You will require the following to perform these tests: Identify the RF channel(s) to be used. Obtain a valid Options Key for each AN-80i unit. This key (string of numbers, letters, and dashes) must be entered into AN-80i configuration to allow full operation of the wireless link. Record the MAC address for each system to be tested/installed (label on AN-80i units). The MAC address is needed to identify each AN-80i and select the correct Options Key to be entered. One or two PCs each having an Ethernet interface port, Web browser software installed (Internet Explorer recommended), and a CAT-5 cross-over Ethernet cable for each PC. A location with adequate space and power facilities. To satisfy FCC and IC RF exposure requirements for RF transmitting devices, the following distances should be maintained between the antenna of this device and persons during device operation: Table 1: FCC & IC RF Recommended Safe Separation Distances
Frequency (GHz) 3.3 - 3.8 4.9 - 5.3 5.4 5.8 Mode PTP / PMP PTP / PMP PTP / PMP PMP PTP Separation Distance 130 cm (52 in) or more 255 cm (101 in) or more 40 cm (16 in) or more 20 cm (8 in) or more 310 cm (122 in) or more

3.

4. 5. 6.

7. Redline does not endorse testing indoors with antennas. The operation of antennas in

close proximity results in poor connectivity due to high RF multipath effect and RF saturation may damage equipment. Indoor testing may require the use of an RF chamber. When performing indoor testing the RF outputs from each AN-80i can be connected together through a static/variable attenuator. Refer to the connection diagrams on the following page.

4.2

Required Test Equipment

1. PC#1: Use a crossover CAT-5 Ethernet cable to connect PC#1 to the PoE Data In port

on the AN-80i. Equipped with a Web browser (requires Internet Explorer 6.0 or higher), and Ethernet port for connection to AN-80i (PTP Slave). The IP address/subnet mask must be set for the same subnet as the AN-80i. Recommended IP settings are: IP address = 192.168.25.22, Net Mask = 255.255.255.0 2. PC#2: Use a crossover CAT-5 Ethernet cable to connect PC#2 to the PoE Data In port on the AN-80i. Equipped with a Web browser and Ethernet port for connection to AN-80i (PTP Master). The IP address/subnet mask must be set for the same subnet as the AN80i. Recommended IP settings are: IP address = 192.168.25.23, Net Mask = 255.255.255.0

70-00074-01-08

Proprietary Redline Communications 2011

Page 2 of 8

March 15, 2011

AN-80i

Installation Guidelines

Figure 1: AN-80i Indoor Test Connection Diagram

Figure 2: AN-80i Outdoor Test Connection Diagram


,

70-00074-01-08

Proprietary Redline Communications 2011

Page 3 of 8

March 15, 2011

AN-80i

Installation Guidelines

Assemble and Configure AN-80i


Unpack the AN-80i and connect all components according to the Quick Test wiring diagrams on page 3. Do not power-on the AN-80i unit at this time. PoE Caution -- Warning to Service Personnel: 48 VDC Customer equipment including personal computers, routers, etc., must be connected only to the INPUT (DATA) port on the PoE unit. Only the outdoors Ethernet interface cable connecting to the AN-80i can be safely connected to the OUTPUT (DATA & POWER) connector. Connecting customer premises Ethernet equipment directly to the OUTPUT (DATA & POWER) connector on the Power-over-Ethernet power adapter may damage customer equipment.

Configure AN-80i Systems


1. Enter the AN-80i Options Key

a) Use an Ethernet cable to connect the PC #1 (192.168.25.22) to the INPUT port of the PoE power adapter. b) Power-on the AN-80i by connecting AC power to the PoE power adapter. c) On the PC, open a browser and enter the default IP address (192.168.25.2). Login to the AN-80i using the factory defaults: Username: admin Password: admin d) Click Product Options in the left hand menu of the Web screen and enter the options key for the this AN-80i unit. Every options key is unique to the MAC address of an AN-80i and keys cannot be reused. Option keys are provided by your local Redline equipment supplier. The options key enables AN-80i features including the maximum Uncoded Burst Rate (UBR) and frequency ranges (region codes). Without the options key, only very limited operation is possible (restricted power, UBR, and frequency selection).

Figure 3: Configuration - Options Key Important: If an AN-80i is placed in-service without first entering a purchased permanent Options Key -- the wireless link will experience a service outage.
2. Configure the AN-80i

For each link, one AN-80i unit must be designated as 'PTP Master' and the second unit as 'PTP Slave'. When powered-on, the PTP Master will actively transmit to establish a link with the (passive) PTP Slave. Click Configure System in the left hand menu of the Web screen and make the recommended settings for each AN-80i. It is recommended to first configure the PTP Slave.
70-00074-01-08 Proprietary Redline Communications 2011 Page 4 of 8 March 15, 2011

AN-80i

Installation Guidelines
Table 2: Web - Recommended Settings
Setting IP Address RF Freq. (MHz) ATPC Enable Adaptive Modulation System Mode Encryption Type Link Length Measurement Mode Radio Enable PTP Slave 192.168.25.2 Must match Master RF setting (Disabled) (Enabled) PTP Slave None Automatic (Enabled) PTP Master 192.168.25.3 Set RF according to network design (Disabled) (Enabled) PTP Master None Automatic (Enabled)

After making these settings, click Save at the bottom of the configuration screen. If the IP address was changed, you must change the address entered in the Web browser to match the new AN-80i IP address. Repeat steps 1 & 2 to configure the PTP Master AN-80i using the second test PC (192.168.25.23) if available. If only one PC is used, move the PC#1 Ethernet connection to the second PoE power adapter.
3. Test the Wireless Connection

The AN-80i units should now be operating on the same RF channel and will automatically negotiate a wireless connection. Use the following steps to verify connectivity: a) From PC #2, enter the IP address of the PTP Slave AN-80i (192.168.25.2) into the Web browser and login to the AN-80i unit. b) On PC #2, open a command line window and use the following command to send a ping message to PC#1 (192.168.25.22) over the wireless interface. ping 192.168.25.22 You should observe a result similar to the following: Reply from 192.168.25.22: bytes=32 time=1ms TTL=63

Field Installation Instructions


These steps should be performed after successfully completing the pre-installation tests and configuration.

Install AN-80i
Install the AN-80i, mounting bracket, and antenna. The maximum length of the Ethernet cable is 100 m (328 ft). For example, 98 m from the AN-80i to the PoE, and then 2 m from the PoE to the network equipment connection. Important: Ethernet Plug Must 'Click' into Socket When inserting the RJ-45 plug, you should hear an audible 'click' from the plastic locking mechanism. Ensure the connector is locked before sealing and weatherproofing the AN-80i. Do not use cables where this locking mechanism is broken or has been removed! Always follow local and national electrical and building codes for grounding and safety. If you have determined that it is appropriate to install lightning protection for your system, refer to the AN-80i Installation Guidelines manual for additional information.

70-00074-01-08

Proprietary Redline Communications 2011

Page 5 of 8

March 15, 2011

AN-80i

Installation Guidelines

8
8.1

Mounting Brackets
Heavy-Duty Mounting Option

Figure 4: AN-80i with 80i-HD-MNT Mounting Kit

8.2

Lightweight Mounting Option

Figure 5: AN-80i with 80i-LD-MNT Mounting

8.3

Stand-Alone Mounting Option

Figure 6: AN-80i with 80i-SA-MNT Mounting Kit


70-00074-01-08 Proprietary Redline Communications 2011 Page 6 of 8 March 15, 2011

AN-80i
1.

Installation Guidelines
Verify Free Channel (Spectrum Sweep)

It is recommended to check that the planned RF channel is available at the deployment site. A spectrum sweep must be performed from both ends of the link. When performing a sweep from the PTP Slave, the PTP Master must be powered-off or have the transmitter disabled. The PTP Slave will remain passive during a spectrum sweep from the PTP Master. a) Login to the AN-80i Web interface and click Spectrum Sweep in the left hand menu. b) Enter the Start Frequency, End Frequency, and Step (multiple of 2.5 MHz) for the spectrum to be scanned. Set the No of Acquisitions to '10' and click the Start button to begin the scan. c) After reviewing the results, enter a narrower frequency scan and higher sample value to monitor a potentially clear channel. d) Repeat the spectrum sweep from the remote-end AN-80i. Note: It is also recommended to use the Redline RF Monitoring Tool. This PC-based application continuously polls both ends of a wireless link and graphs the RSSI and SINADR values in real time. Contact your Redline sales representative to obtain this useful deployment and troubleshooting tool. 2. Align Antennas a) Align each antenna in azimuth and elevation plane. Verify that RSSI values at the base station and subscriber match your link budget predictions. If the RSSI is not within 5 dB of the expected value, recheck the antenna alignment and ensure there are no obstructions in the RF path. Record RSSI/CINR as reference values. b) If desired, you can enable the antenna alignment buzzer. This feature provides an audible signal of the received signal strength (stronger signal->faster repetitions). Click Configure System in the left hand menu of the Web screen and make the following setting: Antenna Alignment Buzzer Enable: (Enabled) The buzzer remains active until disabled by the operator. 3. Connect AN-80i to the Network Make all necessary changes to the AN-80i subscriber station configuration before connecting to the network. Use a CAT-5 Ethernet cable to connect the data network to the Data In port on the PoE power adapter. Refer to the AN-80i User Manual and AN-80i Installation Guidelines manual for further details.

70-00074-01-08

Proprietary Redline Communications 2011

Page 7 of 8