You are on page 1of 176

- >> C O N T E N T S

- >>
1
1.01

1.02

3
3.01

3.02
4
4.01

4.02

5
5.01

5.02

5.03

5.04

PVC building wires


without sheath
H05V-U, H05V-K
H07V-U, H07V-R
H07V-K
H07V-A-R
with sheath
CYKY
CYKYLo
CYMY
YM
NYM
CH-N1VV-R
H03VV-F
H05VV-F
XYMM
Rubber energy cables
H05RR-F
H07RN-F
PVC control and electronic cables
control cables
YSLY
YSLCY
electronic cables
JE-Y(St)Y...Bd
Insulated overhead lines
1kV
1-AES
E-A2Y
NFA2X
AsXSn
PRALEX
AXKA
over 1 kV
25-ADX-K
35-ADX-K
Energy cables 0,6/1 kV
Cu unscreened
1-CYKY
E-YY
EYY multi core
NYY
(N)Y2Y
N2XY
N2X2Y
YKY
Cu armoured
YBY
YRY
Cu screened
E-YCY
NYCY
NYCWY
Al unscreened
1-AYKY
E-AYY
E-XAYY
E-AY2Y
E-XAY2Y
NAYY

- >>

2
3
5
7
8
10
11
12
14
16
18
20
22
23
24

5.05

6
6.01
6.02
7

26
30
33

34
35
36
38
40
41
42
43

44
46
49
51
53
54
55
56

10
10.01

58
60

10.02

61
64
66

10.03

68
70
72
73
74
75

11

(N)AY2Y
NA2XY
NA2X2Y
YAKY
PVIKS-AL-M
PEX-M-AL
TFXP
AXMK
Al screened
AYCWY
SZAMKAM
PFSP
TFSP
AKKJ
Energy cables 1030 kV
Cu
N2XS(F)2Y
Al
NA2XS(F)2Y
Railway signalling cables
A-2Y2YB2Y
Sw-CLT
TD 59 PT
BRQAQAhVQ
Telecommunications cables
J-Y(St)YLg
TPV
TPVBG
F-2YA2Y
F-2YC2Y
A-2Y(L)2YSt III Bd
TCEPKPFLE
TK 59
A-2YF(L)2YSt III Bd
Halogen-free building wires
H05Z-U,-K
H07Z-U,-R,-K
NHXMH
Halogen-free energy cables 0.6/1 kV
Cu unscreened
1-CHKH-R
1CSKHV180
1CSKHV180/E30
1-CHKH-V180
N2XH
NHXH FE180/E30
NHXH FE180/E90
Cu armoured
1-CHKHDH-R
1-CHKHDH-V180
Cu screened
N2XCH
NHXCH FE180/E30
NHXCH FE180/E90
Halogen-free
telecommunications cables
J-H(St)H Bd
JE-H(St)H Bd FE 180/E30, E90

76
77
78
79
80
81
82
83

152
154

General technical information

156

84
85
86
87
88

89
91

93
95
97
99
101
103
104
105
107
109
111
113
115
117
118
120

122
125
127
129
132
134
137

140
143
146
148
150

Page 1

10

11

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

H05VU (YSe) / H05VK (Ysf)


Insulated wire
Standard: VE/NORM E 8241 (HD 21)
Usage:
Suitable for fixed, protected installation in equipment, as well as in
and on lights. Can be used for fixed installation in conduit on and
under plaster but only for signalling installations.

Rated voltage:

300/500 V

Test voltage:

2000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:
2

Core identification:
black (sw), blue (bl), brown (bn), grey (hgr),
violet (vi), green/yellow (gnge), green (gn),
yellow (ge), orange (or), white (ws), red (rt)
Fire properties:
flame retardant

Test certificate:

Cert
.....
..

Colour of core

Max. conductor
resistance
/km)
(

0.5

sw, bl, br, hgr, vi, gnge

36.0

0.75

sw, bl, br, hgr, vi, gnge

24.5

sw, bl, br, hgr, vi, gnge

18.1

max. +160 C/5 s

Bending radius (min.): 4 x of wire

Construction:
1 Copper conductor, solid wire (-U) resp. fine wire (-K)
2 Core insulation (PVC)

Nominal
cross section
(mm2)

min. +5 C
5 C to +70 C
max. +70 C

Outer
diameter
(mm) ca.

.
..

(EN 50265-2-1,
IEC 60332-1)
VE Austria

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

1.8

5.0

100 R

2.1

7.5

12

100 R

2.3

10.0

14

100 R

H05VU (YSe)

H05VK (YSf)
0.5

sw, bl, br

39.0

2.1

5.0

100 R

0.75

sw, bl, br

26.0

2.2

7.5

12

100 R

sw, bl, br

19.5

2.4

10.0

14

100 R

0.5

gnge, hgr, vi, gn, ge, or, ws, rt

39.0

2.1

5.0

100 R

0.75

gnge, hgr, vi, gn, ge, or, ws, rt

26.0

2.2

7.5

12

100 R

gnge, hgr, vi, gn, ge, or, ws, rt

19.5

2.4

10.0

14

100 R

Subject to technical changes.

Page 2

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

H07VU (Ye) / H07VR (Ym)


Insulated wire
Standard: VE/NORM E 8241 (HD 21)
Usage:
For fixed installation in conduit on or under plaster. Suitable for
protected fixed installation in and on lighting installations or control equipment for ac voltages up to 750 V towards earth.

Rated voltage:

450/750 V

Test voltage:

2500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

Test certificate:

Cert
.....
..

Max. conductor
resistance
/km)
(

max. +160 C/5 s

Core identification:
black (sw), blue (bl), brown (br), green/yellow
(gnge), grey (hgr), violet (vi), green (gn), yellow
(ge), orange (or), white (ws), red (rt)
Fire properties:
fire retardant

Colour of core

min. +5 C
5 C to +70 C
max. +70 C

Bending radius (min.): 4 x up to 16 mm2,


5 x 25 up to 50 mm2,
above: 6 x

Construction:
1 Copper conductor, solid wire (-U) resp. stranded wire (-R)
2 Core insulation (PVC)

Nominal
cross section
(mm2)

0uter
diameter
(mm) ca.

.
..

.. .. ...
Sz JZD .
. . ..
.

(EN 50265-2-1,
IEC 60332-1)
VE Austria,
EZ Czech Republic,
EVP Slovak Republic,
GOST Russia

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

H07VU (Ye)
1.5

sw, bl, br

12.1

2.6

15

18

100 R

2.5

sw, bl, br

7.41

3.0

25

29

100 R

sw, bl

4.61

3.9

40

45

100 R

sw, bl, br

3.08

4.1

60

63

100 R

10

sw, bl

1.83

5.3

100

106

100 R

16

sw, bl

1.15

6.3

160

163

100 R

1.5

gnge

12.1

2.6

15

18

100 R

2.5

gnge

7.41

3.0

25

29

100 R

gnge

4.61

3.9

40

45

100 R

gnge

3.08

4.1

60

63

100 R

10

gnge

1.83

5.3

100

106

100 R

16

gnge

1.15

6.3

160

163

100 R

1.5

hgr, vi, gn, ge, or, ws, rt

12.1

2.6

15

18

100 R

2.5

hgr, vi, gn, ge, or, ws, rt

7.41

3.0

25

29

100 R

hgr, vi, gn, ge, or, ws, rt

4.61

3.9

40

45

100 R

hgr, vi, gn, ge, or, ws, rt

3.08

4.1

60

63

100 R

10

hgr, vi, gn, ge, or, ws, rt

1.83

5.3

100

106

100 R

16

hgr, vi, gn, ge, or, ws, rt

1.15

6.3

160

163

100 R

Page 3

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

H07VU (Ye) / H07VR (Ym)


Nominal
cross section
(mm2)

Colour of core

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

H07VR (Ym)
10

sw, bl, br

1.83

5.8

100

110

100 R, 500 Sp, 1000 T

16

sw, bl

1.15

6.3

160

170

100 R, 500 Sp, 1000 T

25

sw

0.727

7.9

250

260

100 R, 500 T, 1000 T

35

sw

0.524

8.5

350

370

100 R, 500 T, 1000 T

50

sw

0.387

11.3

500

530

100 R, 500 T, 1000 T

70

sw

0.268

13.0

700

740

500 T, 1000 T

95

sw

0.193

14.5

950

1,000

500 T, 1000 T

120

sw

0.153

17.1

1,200

1,250

500 T, 1000 T

150

sw

0.124

19.1

1,500

1,580

500 T, 1000 T

185

sw

0.0991

21.4

1,850

1,930

500 T, 1000 T

240

sw

0.0754

24.4

2,400

2,500

500 T, 1000 T

300

sw

0.0601

27.1

3,000

3,130

500 T, 1000 T

10

gnge, special colours

1.830

5.8

100

110

100 R, 500 Sp, 1000 T

16

gnge, special colours

1.150

6.3

160

170

100 R, 500 Sp, 1000 T

25

gnge, special colours

0.727

7.9

250

260

100 R, 500 T, 1000 T

35

gnge, special colours

0.524

8.5

350

370

100 R, 500 T, 1000 T

50

gnge, special colours

0.387

11.3

500

530

100 R, 500 T, 1000 T

70

gnge, special colours

0.268

13.0

700

740

500 T, 1000 T

95

gnge, special colours

0.193

14.5

950

1,000

500 T, 1000 T

120

gnge, special colours

0.153

17.1

1,200

1,250

500 T, 1000 T

150

gnge, special colours

0.124

19.1

1,500

1,580

500 T, 1000 T

185

gnge, special colours

0.0991

21.4

1,850

1,930

500 T, 1000 T

240

gnge, special colours

0.0754

24.4

2,400

2,500

500 T, 1000 T

300

gnge, special colours

0.0601

27.1

3,000

3,130

500 T, 1000 T

Subject to technical changes.

Page 4

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

H07VK (Yf)
Insulated wire
Standard: VE/NORM E 8241 (HD 21)
Usage:
For fixed installation in conduit on or under plaster. Suitable for
protected fixed installation in and on lighting installations or control equipment for ac voltages up to 750 V towards earth.

Rated voltage:

450/750 V

Test voltage:

2500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

max. +160 C/5 s

Core identification:
black (sw), blue (bl), brown (br), green/yellow
(gnge), grey (hgr), violet (vi), green (gn), yellow
(ge), orange (or), white (ws), red (rt)

Fire properties:
flame retardant

Test certificate:

Cert
.....
..

Colour of core

min. +5 C
5 C to +70 C
max. +70 C

Bending radius (min.): 4 x up to 16 mm2,


5 x 25 up to 50 mm2,
above: 6 x

Construction:
1 Copper conductor, fine wire
2 Core insulation (PVC)

Nominal
cross section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

.
..

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

(EN 50265-2-1,
IEC 60332-1)
VE Austria,
EZ Czech Republic,
GOST Russia

Standard lenghts/
packing
(m)

H07VK (Yf)
1.5

sw, bl, br

13.300

2.8

15

20

100 R

2.5

sw, bl, br

7.980

3.6

25

31

100 R

sw, bl, br

4.950

4.0

40

46

100 R, 500 Sp

sw, bl, br

3.300

4.7

60

66

100 R, 500 Sp

10

sw, bl, br

1.910

6.0

100

104

100 R, 500 Sp

16

sw, bl, br

1.210

7.1

160

175

100 R, 500 Sp

25

sw

0.780

9.0

250

280

100 R, 500 T, 1000 T

35

sw

0.554

10.4

350

380

100 R, 500 T, 1000 T

50

sw

0.386

11.8

500

550

100 R, 500 T, 1000 T

70

sw

0.272

14.8

700

760

500 T, 1000 T

95

sw

0.206

16.4

950

1,020

500 T, 1000 T

120

sw

0.161

17.5

1,200

1,280

500 T, 1000 T

150

sw

0.129

19.0

1,500

1,600

500 T, 1000 T

185

sw

0.106

22.0

1,850

1,960

500 T, 1000 T

240

sw

0.080

27.0

2,400

2,550

500 T, 1000 T

Page 5

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

H07VK (Yf)
Nominal
cross section
(mm2)

Colour of core

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

H07VK (Yf)
1.5

gnge, special colours

13.300

2.8

15

20

100 R

2.5

gnge, special colours

7.980

3.6

25

31

100 R

gnge, special colours

4.950

4.0

40

46

100 R, 500 Sp

gnge, special colours

3.300

4.7

60

66

100 R, 500 Sp

10

gnge, special colours

1.910

6.0

100

104

100 R, 500 Sp

16

gnge, special colours

1.210

7.1

160

175

100 R, 500 Sp

25

gnge, special colours

0.780

9.0

250

280

100 R, 500 T, 1000 T

35

gnge, special colours

0.554

10.4

350

380

100 R, 500 T, 1000 T

50

gnge, special colours

0.386

11.8

500

550

100 R, 500 T, 1000 T

70

gnge, special colours

0.272

14.8

700

760

500 T, 1000 T

95

gnge, special colours

0.206

16.4

950

1,020

500 T, 1000 T

120

gnge, special colours

0.161

17.5

1,200

1,280

500 T, 1000 T

150

gnge, special colours

0.129

19.0

1,500

1,600

500 T, 1000 T

185

gnge, special colours

0.106

22.0

1,850

1,960

500 T, 1000 T

240

gnge, special colours

0.080

27.0

2,400

2,550

500 T, 1000 T

Subject to technical changes.

Page 6

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

H07VAR
Insulated wire
Standard: adapted to SN 347410-3 (HD 21.3-3)
Usage:
For fixed installation in conduit, under plaster or in equipment and
distributors.

Rated voltage:

450/750 V

Test voltage:

2500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

Core identification:

Fire properties:
flame retardant

.....
..

Current rating
in air1)
(A)

max. +160 C/5 s

Outer
diameter
(mm) ca.

.
..

green/yellow (gnge),
black (sw), blue (bl),
brown (br), red (rt) and
other colours on request

(EN 50265-2-1,
IEC 60332-1)

Test certificate:

Cert

Max. conductor
resistance
(/km)

min. 5 C
30 C to +70 C
max. +70 C

Bending radius (min.):


4 x of wire for 8 mm
5 x of wire for > 8 mm

Construction:
1 Aluminium conductor, stranded wire (-R)
2 Core insulation (PVC)

Nominal cross
section
(mm2)

EVP Slovak Republic

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

H07VAR
25

1.200

112

5.5

75

108

1000 T

35

0.868

139

8.4

105

146

1000 T

50

0.641

169

11.4

150

190

1000 T

70

0.443

217

12.9

210

268

1000 T

95

0.320

265

15.0

285

365

1000 T

120

0.253

309

17.1

360

449

1000 T

150

0.206

364

16.4

450

541

1000 T

185

0.164

417

18.1

555

668

1000 T

240

0.129

486

27.2

720

879

1000 T

300

0.100

562

26.8

900

1,089

1000 T

1) basic rated current acc. to SN 347410-3 (HD 21.3-3)


Subject to technical changes.

Page 7

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

CYKY
Underground cable with PVC insulation and PVC sheath
Standard: TP PRAKAB 01/03
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in
interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical
damage is to be expected.

Rated voltage:

450/750 V

Test voltage:

2500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
50 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.):


12 x of cable for 15 mm
15 x of cable for > 15 mm
4

Core identification:

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PVC). Conductors stranded together.
3 Inner covering (EPDM)
4 Sheath (PVC black, UV-resistant)

Fire properties:
flame retardant

Test certificate:

Cert
.....
..

Number
of cores x
nominal cross
section
(mm2)

Max.
conductor
resistance
(/km)

Current carry- Current carrying capacity in ing capacity in


the air1)
the ground1)
(A)
(A)

.
..

.. .. ...
Sz JZD .
. . ..
.

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
EZ Czech Republic,
GOST Russia,
EVP Slovak Republic

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

CYKY
2 x 1.5 RE

12.531

34

22

8.1

29

102

100 R, 500 Sp

3 x 1.5 RE

12.531

28

18

8.6

44

119

100 R, 500 Sp

4 x 1.5 RE

12.531

28

18

9.3

59

147

100 R, 500 Sp

5 x 1.5 RE

12.531

28

18

10.1

74

173

100 R, 500 Sp

7 x 1.5 RE

12.531

18

11

11.0

103

222

1000 T

12 x 1.5 RE

12.531

13

14.6

176

386

1000 T

19 x 1.5 RE

12.531

11

17.0

279

562

1000 T

24 x 1.5 RE

12.531

20.1

353

716

1000 T

37 x 1.5 RE

12.531

22.9

544

1,118

1000 T

48 x 1.5 RE

12.531

26.6

706

1,301

1000 T

2 x 2.5 RE

7.520

45

30

8.9

49

139

100 R, 500 Sp

3 x 2.5 RE

7.520

38

25

9.5

74

167

100 R, 500 Sp

4 x 2.5 RE

7.520

38

25

10.3

98

210

100 R, 500 Sp

5 x 2.5 RE

7.520

38

25

11.2

123

257

100 R, 500 Sp

7 x 2.5 RE

7.520

23

15

12.2

172

337

1000 T

12 x 2.5 RE

7.520

17

12

16.3

294

568

1000 T

19 x 2.5 RE

7.520

14

10

19.3

466

832

1000 T

24 x 2.5 RE

7.520

12

22.5

588

1,077

1000 T

37 x 2.5 RE

7.520

10

26.1

907

1,569

1000 T

48 x 2.5 RE

7.520

29.8

1,176

1,995

1000 T

Page 8

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

CYKY
Number
of cores x
nominal cross
section
(mm2)

Max.
conductor
resistance
(/km)

Current carry- Current carrying capacity in ing capacity in


the air1)
the ground1)
(A)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

2 x 4 RE

4.700

59

40

10.6

78

213

1000 T

3 x 4 RE

4.700

48

34

11.2

118

253

1000 T

4 x 4 RE
5 x 4 RE

4.700

48

34

12.2

157

314

1000 T

4.700

48

34

13.8

196

376

1000 T

CYKY

7 x 4 RE

4.700

29

20

15.0

274

485

1000 T

12 x 4 RE

4.700

22

16

20.0

470

870

1000 T

2 x 6 RE

3.133

73

51

11.6

118

260

1000 T

3 x 6 RE

3.133

61

43

12.3

176

325

1000 T

4 x 6 RE

3.133

61

43

13.8

235

405

1000 T

5 x 6 RE

3.133

61

43

15.1

294

500

1000 T

3 x 10 RE

1.880

81

60

14.7

294

494

1000 T

4 x 10 RE

1.880

81

60

16.1

392

642

1000 T

5 x 10 RE

1.880

81

60

18.0

490

770

1000 T

3 x 16 RE

1.175

105

80

16.7

470

719

1000 T

4 x 16 RE

1.175

105

80

18.6

627

921

1000 T

5 x 16 RE

1.175

105

80

20.4

784

1,138

1000 T

1) basic rated current acc. to TP PRAKAB 01/03


Subject to technical changes.

Page 9

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

CYKYLo
Flat cable
Standard: TP PRAKAB 01/03
Usage:
For fixed installation under plaster, in conduit and in installation
strips.

Rated voltage:

450/750 V

Test voltage:

2500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:
3

min. +4 C
50 C to +70 C
max. +70 C
max. +160 C/5 s

1
Bending radius (min.): 6 x cable height
or 6 x cable width

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PVC)
3 Sheath (PVC black, UV-resistant)

Core identification:
Fire properties:
flame retardant

Test certificate:

Cert
.....
..

Number
of cores x
nominal cross
section
(mm2)

Max.
conductor
resistance
(/km)

Current carrying capacity in


the air1)
(A)

Cable width
(mm) ca.

2 x 1.5 RE

12.531

22

6.7

3 x 1.5 RE

12.531

18

2 x 2.5 RE

7.520

30

3 x 2.5 RE

7.520

25

.
..

.. .. ...
Sz JZD .
. . ..
.

Cable height
(mm) ca.

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
EZ Czech Republic,
EVP Slovak Republic

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

3.9

29

57

100 R

9.5

3.9

44

79

100 R

7.5

4.3

49

81

100 R

10.7

4.3

74

120

100 R

CYKYLo

1) basic rated current acc. to TP PRAKAB 01/03


Subject to technical changes.

Page 10

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

CYMY
Flat webbed cable
Standard: TP PRAKAB 14/03
Usage:
For fixed installation under plaster, in conduit and in installation
strips.

Rated voltage:

300/500 V

Test voltage:

2500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:
3

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PVC)
3 Sheath (PVC black, UV-resistant)

min. +4 C
50 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 6 x cable height


or 6 x cable width
Core identification:
Fire properties:
flame retardant

Test certificate:

Cert
.....
..

Number
of cores x
nominal cross
section
(mm2)

Max.
conductor
resistance
(/km)

Current carrying capacity in


the air1)
(A)

Cable width
(mm) ca.

2 x 1.5 RE

12.531

22

9.6

3 x 1.5 RE

12.531

22

2 x 2.5 RE

7.520

30

3 x 2.5 RE

7.520

30

.
..

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
EZ Czech Republic

.. .. ...
Sz JZD .
. . ..
.

Cable height
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

3.3

29

49.0

100 R

15.9

3.3

44

75.0

100 R

12.0

4.0

49

83.0

100 R

20.0

4.0

74

120.0

100 R

CYMY

1) basic rated current acc. to TP PRAKAB 14/03


Subject to technical changes.

Page 11

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

YM
Installation cable
Standard: VE/NORM E 8241
Usage:
For fixed installation in dry and damp premises. Not suitable for
installation in the open air or directly in concrete.

Fire properties:
flame retardant

.....
..

2 x 1.5 RE

12.1

3 x 1.5 RE
4 x 1.5 RE
5 x 1.5 RE

12.1

7 x 1.5 RE

12.1

2 x 2.5 RE

7.41

3 x 2.5 RE

7.41

4 x 2.5 RE

2000 Veff

Core identification:

Test certificate:

Cert

Outer
diameter
(mm) ca.

Test voltage:

min. +5 C
40 C up to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 4 x of cable

Construction:
1 Copper conductor, round solid (RE) resp. round stranded (RM)
2 Core insulation (PVC)
3 Inner covering (EPDM)
4 Sheath (PVC grey or special colour)

Max. conductor
resistance
/km)
(

300/500 V

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

Number of cores x
nominal cross
section
(mm2)

Rated voltage:

.
..

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
VE Austria

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

7.0

30

91

50 R, 100 R, 500 Sp, 1000 Sp

12.1

7.8

45

111

50 R, 100 R, 500 Sp, 1000 Sp

12.1

8.3

60

132

50 R, 100 R, 500 Sp, 1000 Sp

9.1

75

157

50 R, 100 R, 500 Sp, 1000 Sp

10.1

105

203

500 Sp, 1000 Sp

8.6

50

131

50 R, 100 R, 500 Sp, 1000 Sp

8.9

75

159

500 Sp, 1000 Sp

7.41

10.3

100

208

500 Sp, 1000 Sp

5 x 2.5 RE

7.41

10.7

125

234

500 Sp, 1000 Sp

7 x 2.5 RE

7.41

12.3

175

313

500 Sp, 1000 T

2 x 4 RE

4.61

9.4

80

173

50 R, 100 R, 500 Sp, 1000 Sp

3 x 4 RE

4.61

10

120

225

500 Sp, 1000 T

4 x 4 RE

4.61

11

160

283

500 Sp, 1000 T

5 x 4 RE

4.61

12.4

200

330

500 Sp, 1000 T

2 x 6 RE

3.08

10.3

120

238

500 Sp, 1000 T

3 x 6 RE

3.08

12.3

180

323

500 Sp, 1000 T

4 x 6 RE

3.08

14.0

240

421

500 Sp, 1000 T

YM-O

5 x 6 RE

3.08

14.2

300

453

500 Sp, 1000 T

2 x 10 RE

1.83

14.2

200

409

500 Sp, 1000 T

3 x 10 RE

1.83

15.0

300

503

500 T, 1000 T

Page 12

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

YM
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

YM-O
4 x 10 RE

1.83

17.1

400

665

500 T, 1000 T

4 x 10 RM

1.83

17.3

400

670

500 T, 1000 T

5 x 10 RE

1.83

18.1

500

752

500 T, 1000 T

2 x 16 RM

1.15

17.0

320

603

500 T, 1000 T

3 x 16 RM

1.15

18.4

480

772

500 T, 1000 T

4 x 16 RM

1.15

20.1

640

975

500 T, 1000 T

5 x 16 RM

1.15

22.3

800

1,162

500 T, 1000 T

YM-J
3 x 1.5 RE

12.1

7.8

45

111

50 R, 100 R, 500 Sp, 1000 Sp

4 x 1.5 RE

12.1

8.3

60

132

50 R, 100 R, 500 Sp, 1000 Sp

5 x 1.5 RE

12.1

9.1

75

157

50 R, 100 R, 500 Sp, 1000 Sp

7 x 1.5 RE

12.1

10.1

105

203

50 R, 100 R, 500 Sp, 1000 Sp

3 x 2.5 RE

7.41

8.9

75

159

50 R, 100 R, 500 Sp, 1000 Sp

4 x 2.5 RE

7.41

10.3

100

208

50 R, 100 R, 500 Sp, 1000 Sp

5 x 2.5 RE

7.41

10.7

125

234

50 R, 100 R, 500 Sp, 1000 Sp

7 x 2.5 RE

7.41

12.3

175

313

50 R, 100 R, 500 SP, 1000 T

3 x 4 RE

4.61

10

120

225

50 R, 100 R, 500 SP, 1000 T

4 x 4 RE

4.61

11

160

283

50 R, 100 R, 500 SP, 1000 T

5 x 4 RE

4.61

12.4

200

330

50 R, 100 R, 500 SP, 1000 T

3 x 6 RE

3.08

12.3

180

323

50 R, 100 R, 500 SP, 1000 T

4 x 6 RE

3.08

14.0

240

421

50 R, 100 R, 500 SP, 1000 T

5 x 6 RE

3.08

14.2

300

453

50 R, 100 R, 500 SP, 1000 T

3 x 10 RE

1.83

15.0

300

503

500 T, 1000 T

4 x 10 RE

1.83

17.1

400

665

500 T, 1000 T

5 x 10 RE

1.83

18.1

500

752

500 T, 1000 T

4 x 10 RM

1.83

17.3

400

670

500 T, 1000 T

5 x 10 RM

1.83

19.0

500

802

500 T, 1000 T

3 x 16 RM

1.15

18.4

480

772

500 T, 1000 T

4 x 16 RM

1.15

20.1

640

975

500 T, 1000 T

5 x 16 RM

1.15

22.3

800

1,162

500 T, 1000 T

Subject to technical changes.

Page 13

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

NYM
Installation cable
Standard: VDE 0250 Part 204
Usage:
For fixed installation in dry, damp or wet premises.

Outer
diameter
(mm) ca.

2 x 1.5 RE

12.10

3 x 1.5 RE
4 x 1.5 RE

Test voltage:

2000 Veff

min. +5 C
40 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 4 x of cable

Construction:
1 Copper conductor, round solid (RE) resp. round stranded (RM)
2 Core insulation (PVC). Conductors stranded to the cable core.
3 Inner covering (EPDM)
4 Sheath (PVC grey RAL 7035)

Max. conductor
resistance
/km)
(

300/500 V

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

Number of cores x
nominal cross
section
(mm2)

Rated voltage:

Core identification:
Fire properties:
flame retardant

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

8.5

29

114

100 R, 500 Sp

12.10

8.9

44

130

100 R, 500 Sp

12.10

9.5

59

167

100 R, 500 Sp

5 x 1.5 RE

12.10

10.2

74

180

100 R, 500 Sp

7 x 1.5 RE

12.10

11.0

103

231

1000 T

2 x 2.5 RE

7.41

9.7

49

156

100 R, 500 Sp

3 x 2.5 RE

7.41

10.2

74

193

100 R, 500 Sp

4 x 2.5 RE

7.41

11.0

98

225

100 R, 500 Sp

5 x 2.5 RE

7.41

11.9

123

264

100 R, 500 Sp

7 x 2.5 RE

7.41

12.8

172

333

1000 T

2 x 4 RE

4.61

11.1

78

219

1000 T

3 x 4 RE

4.61

11.7

118

262

1000 T

4 x 4 RE

4.61

13.0

157

328

1000 T

5 x 4 RE

4.61

14.5

196

404

1000 T

2 x 6 RE

3.8

12.1

118

215

1000 T

3 x 6 RE

3.8

13.1

176

350

1000 T

4 x 6 RE

3.8

14.6

235

442

1000 T

5 x 6 RE

3.8

15.8

294

523

1000 T

2 x 10 RE

1.83

15.4

196

450

1000 T

3 x 10 RE

1.83

16.3

294

548

1000 T

4 x 10 RE

1.83

17.7

392

669

1000 T

NYM

5 x 10 RE

1.83

19.3

490

798

1000 T

2 x 16 RM

1.15

17.8

314

642

1000 T

3 x 16 RM

1.15

19.3

470

812

1000 T

Page 14

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

NYM
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

NYM
4 x 16 RM

1.15

20.9

627

1,047

1000 T

5 x 16 RM

1.15

23.3

784

1,273

1000 T

2 x 25 RM

0.727

21.9

490

958

1000 T

3 x 25 RM

0.727

23.2

735

1,208

1000 T

4 x 25 RM

0.727

25.3

980

1,521

1000 T

5 x 25 RM

0.727

28.1

1,225

1,819

1000 T

2 x 35 RM

0.524

24.8

686

1,27

1000 T

3 x 35 RM

0.524

26.3

1,029

1,584

1000 T

4 x 35 RM

0.524

28.7

1,372

1,961

1000 T

5 x 35 RM

0.524

31.5

1,715

2,393

1000 T

Subject to technical changes.

Page 15

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

CHN1VVR (TTKABEL)
Installation cables
Standard: SEV 1101
Usage:
Installation and control cable for fixed installation in dry, damp or
wet interior premises or in cable ducts in domestic and industrial
installations as permitted by the local building regulations .

Rated voltage:

0.6/1 V

Test voltage:

3500 Veff

Temperature range:
laying temperature:
5 to +50 C
operating temperature: 20 C to +70 C
conductor temperature: max. +70 C
Bending radius (min.): 6 x of cable
Core identification:
4

Construction:
1 Copper conductor, round stranded (RM)
2 Core insulation (PVC)
3 Inner covering (EPDM) in case of multicore constructions
4 Sheath (PVC grey RAL 7035)

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

coloured (SEV)

Outer
diameter
(mm) ca.

Fire properties:
flame retardant

Test certificate:

Cert
.....
..

.
..

(EN 50265-2-1,
IEC 60332-1)
SEV Switzerland

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

CHN1VVR (TTKABEL)
1 x 25

0.727

10.6

240

311

500 T, 1000 T

1 x 35

0.524

11.9

336

419

500 T, 1000 T

1 x 50

0.387

13.5

480

551

500 T, 1000 T

1 x 70

0.268

15.6

672

782

500 T, 1000 T

1 x 95

0.193

17.6

912

1,051

500 T, 1000 T

1 x 120

0.153

19.3

1,152

1,293

500 T, 1000 T

1 x 150

0.124

21.2

1,440

1,579

500 T, 1000 T

1 x 185

0.0991

23.9

1,776

2,000

500 T, 1000 T

1 x 240

0.0754

27.4

2,304

2,601

500 T, 1000 T

1 x 300

0.0601

30.1

2,880

3,233

500 T, 1000 T

4 x 10

1.83

18.4

384

608

500 T, 1000 T

5 x 10

1.83

19.8

480

760

500 T, 1000 T

4 x 16

1.15

22

615

972

500 T, 1000 T

5 x 16

1.15

23.5

768

1,164

500 T, 1000 T

4 x 25

0.727

25.7

960

1,468

500 T, 1000 T

5 x 25

0.727

27.3

1,200

1,758

500 T, 1000 T

4 x 35

0.524

27.8

1,344

1,915

500 T, 1000 T

5 x 35

0.524

30.2

1,680

2,389

500 T, 1000 T

4 x 50

0.387

30.5

1,920

2,589

500 T, 1000 T

5 x 50

0.387

34.3

2,400

3,136

500 T, 1000 T

Page 16

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

CHN1VVR (TTKABEL)
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

CHN1VVR (TTKABEL)
4 x 70

0.268

35

2,688

3,574

500 T, 1000 T

5 x 70

0.268

40.5

3,360

4,403

500 T, 1000 T

4 x 95

0.193

41.3

3,640

4,961

500 T, 1000 T

5 x 95

0.193

47

4,560

6,044

500 T, 1000 T

Subject to technical changes.


Note: This cable is also available in the version TT-CLT (steel tape armouring and black sheath) on special request

Page 17

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

H03VVF (YML) / A03VVF (YML)


Light flexible cable
Standard: VE/NORM E 8241 (HD 21)
Usage:
Can be used in areas subject to low mechanical stressing in households and office premises for light hand-held appliances except
for cooking and heating appliances. Not suitable for installation
in the open air, in industrial premises or for connection of industrial power tools.

Rated voltage:

300/300 V

Test voltage:

2000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. +5 C
+5 C to +50 C
max. +60 C
max. +150 C/5 s

Bending radius (min.): 3 x of cable


3

1
Core identification:

Construction:
1 Copper conductor, fine wire
2 Core insulation (PVC)
3 Sheath (PVC grey RAL 7035 resp. special colours)

Fire properties:
flame retardant

.....
..

Number of cores x Colour of sheath


nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Outer
diameter
(mm) ca.

(EN 50265-2-1,
IEC 60332-1)

Test certificate:

Cert
.
..

coloured (HD 308 S2)

VE Austria,
EZ Czech Republic,
GOST Russia

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

H03VVF (YMLO)
2 X 0.5

hgr

39.0

4.7

10

39

50 R, 100 R

2 X 0.75

hgr

26.0

5.2

15

48

50 R, 100 R

2X1

hgr

19.5

20

51

50 R, 100 R

3 G 0.5

hgr

39.0

15

46

50 R, 100 R

A03VVF (YMLO)
5.5
H03VVF (YMLJ)
5.0

4 G 0.5

hgr

39.0

5.6

20

56

500 Sp, 1000 Sp

3 G 0.75

hgr

26.0

5.5

22.5

55

50 R, 100 R

4 G 0.75

hgr

26.0

6.1

30

70

50 R, 100 R

5 G 0.75

hgr

26.0

6.8

37.5

83

50 R, 100 R

A03VVF (YMLJ)
G1

hgr

19.5

5.9

30

62

50 R, 100 R

4G1

hgr

19.5

6.5

40

75

50 R, 100 R

2 X 0.5

sw, ws, br

39.0

4.7

10

39

500 Sp, 1000 Sp

2 X 0.75

sw, ws, br

26.0

5.2

15

48

500 Sp, 1000 Sp

20

51

500 Sp, 1000 Sp

H03VVF (YMLO)

A03VVF (YMLO)
2X1

Page 18

sw, ws, br

19.5

5.4

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

H03VVF (YML) / A03VVF (YML)


Number of cores x Colour of sheath
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

15

46

500 Sp, 1000 Sp

H03VVF (YMLJ)
3 G 0.5

sw, ws, br

39.0

5.0

4 G 0.5

sw, ws, br

39.0

5.6

20

56

500 Sp, 1000 Sp

3 G 0.75

sw, ws, br

26.0

5.5

22.5

55

50 R, 100 R

4 G 0.75

sw, ws, br

26.0

6.1

30

70

500 Sp, 1000 Sp

5 G 0.75

sw, ws, br

26.0

6.8

37.5

83

500 Sp, 1000 Sp

3G1

sw, ws, br

19.5

5.8

30

62

500 Sp, 1000 Sp

4G1

sw, ws, br

19.5

6.3

40

75

500 Sp, 1000 Sp

A03VVF (YMLJ)

Subject to technical changes.

Page 19

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

H05VVF (YMM) / A05VVF (YMM)


Flexible cable
Standard: VE/NORM E 8241 (HD 21)
Usage:
Can be used in areas subject to moderate mechanical stressing in
households and office premises and for domestic appliances (including those in damp premises). Not suitable for installation in the
open air, in industrial premises or for connection of power tools
used industrially.

Rated voltage:

300/500 V

Test voltage:

2000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. +5 C
+5 C to +50 C
max. +60 C
max. +150 C/5 s

Bending radius (min.): 3 x of cable


3

1
Core identification:

Construction:
1 Copper conductor, fine wire
2 Core insulation (PVC)
3 Sheath (PVC grey RAL 7035 resp. special colours)

Fire properties:
flame retardant

Test certificate:

Cert
.....
..

Number
of cores x
nominal cross
section
(mm2)

Colour
of sheath

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

2 X 0.75

hgr

26.0

5.8

3 X 0.75

hgr

26.0

4 X 0.75

hgr

5 X 0.75

hgr

2X1
3X1

Metal
weight
(kg/km)

.
..

.. .. ...
Sz JZD .
. . ..
.

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
VE Austria,
EZ Czech Republic,
GOST Russia

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

15.0

57

500 Sp, 1000 Sp

6.2

22.5

67

500 Sp, 1000 Sp

26.0

6.7

30.0

79

500 Sp, 1000 Sp

26.0

7.7

37.5

97

500 Sp, 1000 Sp

hgr

19.5

6.2

20.0

64

50 R, 100 R

hgr

19.5

6.6

30.0

76

500 Sp, 1000 Sp

4X1

hgr

19.5

7.4

40.0

96

500 Sp, 1000 Sp

5X1

hgr

19.5

8.1

50.0

112

500 Sp, 1000 Sp

2 X 1.5

hgr

13.3

7.1

30.0

86

50 R, 100 R, 500 Sp

3 X 1.5

hgr

13.3

7.6

45.0

107

500 Sp, 1000 Sp

4 X 1.5

hgr

13.3

8.5

60.0

132

500 Sp, 1000 Sp

5 X 1.5

hgr

13.3

9.5

75.0

165

500 Sp, 1000 Sp

2 X 2.5

hgr

7.98

8.8

50.0

129

50 R, 100 R, 500 Sp, 1000 Sp

3 X 2.5

hgr

7.98

9.3

75.0

154

500 Sp, 1000 Sp

4 X 2.5

hgr

7.98

10.4

100.0

195

500 Sp, 1000 Sp

5 X 2.5

hgr

7.98

11.7

125.0

239

500 Sp, 1000 Sp

H05VVF (YMMO)

H05VVF (YMMJ)
3 G 0.75

hgr

26.0

6.2

22.5

67

500 Sp, 1000 Sp

4 G 0.75

hgr

26.0

6.7

30.0

79

500 Sp, 1000 Sp

Page 20

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

H05VVF (YMM) / A05VVF (YMM)


Number
of cores x
nominal cross
section
(mm2)

Colour
of sheath

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

5 G 0.75

hgr

26.0

7.7

3G1

hgr

19.5

4G1

hgr

5G1

hgr

3 G 1.5
4 G 1.5

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

37.5

97

500 Sp, 1000 Sp

6.6

30.0

76

50 R, 100 R, 500 Sp

19.5

7.4

40.0

96

50 R, 100 R, 500 Sp

19.5

8.1

50.0

112

50 R, 100 R, 500 Sp

hgr

13.3

7.6

45.0

107

50 R, 100 R, 500 Sp

hgr

13.3

8.5

60.0

132

50 R, 100 R, 500 Sp

5 G 1.5

hgr

13.3

9.5

75.0

165

50 R, 100 R, 500 Sp

3 G 2.5

hgr

7.98

9.3

75.0

154

50 R, 100 R, 500 Sp

4 G 2.5

hgr

7.98

10.4

100.0

195

50 R, 100 R, 500 Sp

5 G 2.5

hgr

7.98

11.7

125.0

239

50 R, 100 R, 500 Sp

4G4

hgr

4.95

12.0

160.0

283

50 R, 100 R, 500 T, 1000 T

5G4

hgr

4.95

13.3

200.0

320

50 R, 100 R, 500 T, 1000 T

4G6

hgr

3.30

14.7

240.0

379

50 R, 100 R, 500 T, 1000 T

5G6

hgr

3.30

16.7

300.0

473

50 R, 100 R, 500 T, 1000 T

H05VVF (YMMJ)

A05VVF (YMMJ)
7 G 0.75

hgr, sw

26.0

8.5

52.5

130

500 T, 1000 T

10 G 0.75

hgr, sw

26.0

11.0

75.0

200

500 T, 1000 T

12 G 0.75

hgr, sw

26.0

11.5

90.0

230

500 T, 1000 T

14 G 0.75

hgr, sw

26.0

12.0

105.0

260

500 T, 1000 T

16 G 0.75

hgr, sw

26.0

13.0

120.0

290

500 T, 1000 T

19 G 0.75

hgr, sw

26.0

14.0

142.5

340

500 T, 1000 T

7G1

hgr, sw

19.5

9.0

70.0

136

500 T, 1000 T

10 G 1

hgr, sw

19.5

11.7

100.0

210

500 T, 1000 T

12 G 1

hgr, sw

19.5

12.1

120.0

233

500 T, 1000 T

14 G 1

hgr, sw

19.5

13.0

140.0

300

500 T, 1000 T

16 G 1

hgr, sw

19.5

13.9

160.0

307

500 T, 1000 T

19 G 1

hgr, sw

19.5

14.5

190.0

349

500 T, 1000 T

7 G 1.5

hgr, sw

13.3

10.6

105.0

189

50 R, 100 R, 500 Sp, 1000 T

10 G 1.5

hgr, sw

13.3

13.7

150.0

286

500 T, 1000 T

12 G 1.5

hgr, sw

13.3

14.2

180.0

323

500 T, 1000 T

14 G 1.5

hgr, sw

13.3

14.9

210.0

363

500 T, 1000 T

16 G 1.5

hgr, sw

13.3

16.0

240.0

480

500 T, 1000 T

19 G 1.5

hgr, sw

13.3

16.4

285.0

463

500 T, 1000 T

7 G 2.5

hgr, sw

7.98

13.0

175.0

294

500 T, 1000 T

10 G 2.5

hgr, sw

7.98

16.5

250.0

431

500 T, 1000 T

12 G 2.5

hgr, sw

7.98

17.5

300.0

570

500 T, 1000 T

14 G 2.5

hgr, sw

7.98

18.3

350.0

564

500 T, 1000 T

16 G 2.5

hgr, sw

7.98

20.0

400.0

750

500 T, 1000 T

19 G 2.5

hgr, sw

7.98

21.0

475.0

850

500 T, 1000 T

Subject to technical changes.

Page 21

- >> PVC BUILDING WIRES

SKW | PRAKAB | Products

XYMM K35
Building site cable
Standard: VE/NORM E 8241
Usage:
Can be laid as unprotected movable cable for moderate mechanical stressing in the open air, e.g. on building sites, in industrial
premises or also in dry and damp premises, for fixed installation;
can be used for direct installation on lifting tools, machines etc.

Rated voltage:

450/750 V

Test voltage:

2500 Veff

Temperature range:
laying temperature:
min. 35 C
operating temperature: fixed 40 C to +50 C
in motion 35 C to +50 C
conductor temperature: max. +60 C
short-circuit
temperature:
max. +150 C/5 s
Bending radius (min.): 3 x (fixed installation)
5 x (free motion)

Construction:
1 Copper conductor, fine wire
2 Core insulation (PVC resistant to low temperatures)
3 Sheath (PVC resistant to low temperatures, orange); printing
to customer specification possible

Core identification:
Fire properties:
flame retardant

Test certificate:

Cert
.....
..

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

2 x 1.5

13.3

9.5

.
..

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
TV Austria

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

30

133

500 Sp, 1000 Sp

XYMMO K35

XYMMJ K35
3 x 1.5

13.3

10.0

45

120

100 R, 500 Sp, 1000 Sp

4 x 1.5

13.3

11.0

60

150

100 R, 500 Sp, 1000 Sp

5 x 1.5

13.3

12.0

75

172

100 R, 500 Sp, 1000 Sp

3 x 2.5

7.98

12.0

75

174

100 R, 500 Sp, 1000 Sp

4 x 2.5

7.98

13.0

100

219

100 R, 500 Sp, 1000 Sp

5 x 2.5

7.98

14.0

125

285

100 R, 500 Sp, 1000 T

4x4

4.95

14.5

160

320

500 T, 1000 T

5x4

4.95

16.5

200

359

500 T, 1000 T

4x6

3.3

16.5

240

400

500 T, 1000 T

5x6

3.3

18.0

300

496

500 T, 1000 T

4 x 10

1.91

22.0

400

770

500 T, 1000 T

5 x 10

1.91

24.0

500

891

500 T, 1000 T

4 x 16

1.21

25.0

640

1,070

500 T, 1000 T

5 x 16

1.21

27.5

800

1,256

500 T, 1000 T

Subject to technical changes.

Page 22

- >> RUBBER ENERGY CABLES

SKW | PRAKAB | Products

H05RRF (GML)
Light flexible cable
Standard: VE K 40 (HD 22)
Usage:
For use with light to moderate mechanical stressing in households
and office premises for light electrical equipment. Not suitable for
continuous use in the open air or for use in premises used industrially.

Rated voltage:

300/500 V

Test voltage:

2000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 25 C
25 C to +50 C
max. +60 C
max. +200 C/5 s

Bending radius (min.): 4 x of cable


3

Construction:
1 Copper conductor, fine wire
2 Core insulation (rubber)
3 Sheath (rubber black)

Cert
.....
..

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

2 X 0.75

26.7

7.0

3 G 0.75

26.7

7.5

4 G 0.75

26.7

8.0

5 G 0.75

26.7

8.5

.
..

Core identification:

coloured (HD 308 S2)

Test certificate:

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

15

61

500 Sp, 1000 Sp

22.5

74

100 R, 500 Sp, 1000 Sp

30

90

500 Sp, 1000 Sp

37.5

110

500 Sp, 1000 Sp

H05RRF (GML)

2X1

20.0

7.7

20

71

500 Sp, 1000 Sp

3G1

20.0

8.0

30

83

100 R, 500 Sp, 1000 Sp

4G1

20.0

8.5

40

105

500 Sp, 1000 Sp

5G1

20.0

9.5

50

140

500 Sp, 1000 Sp

2 X 1.5

13.7

8.5

30

110

500 Sp, 1000 Sp

3 G 1.5

13.7

9.0

45

125

100 R, 500 Sp, 1000 Sp

4 G 1.5

13.7

10.0

60

160

100 R, 500 Sp, 1000 Sp

5 G 1.5

13.7

11.5

75

195

100 R, 500 Sp, 1000 Sp

2 X 2.5

8.2

10.5

50

150

500 Sp, 1000 Sp

3 G 2.5

8.2

11.0

75

180

100 R, 500 Sp, 1000 Sp

4 G 2.5

8.2

12.0

100

240

100 R, 500 Sp, 1000 Sp

5 G 2.5

8.2

13.0

125

290

100 R, 500 Sp, 1000 Sp

Subject to technical changes.

Page 23

- >> RUBBER ENERGY CABLES

SKW | PRAKAB | Products

H07RNF (GMSu) / A07RNF (GMSu)


Heavy flexible cable, oil resistant
Standard: VE K 40 (HD 22)
Usage:
Can be used under moderate to heavy mechanical loading in dry
and damp premises, in the open air or in premises where there is
a risk of explosion. Can be used for fixed installation on components of lifting tools, machines etc and for voltages up to 1000 V
for protected installation in conduit or in equipment and as rotor
connecting cable for motors.

Rated voltage:

450/750 V

Test voltage:

2500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 25 C
25 C to +50 C
max. +60 C
max. +200 C/5 s

Bending radius (min.): 4 x of cable


3

Core identification:

Construction:
1 Copper conductor, fine wire tinned resp. not tinned
2 Core insulation (EPR-rubber)
3 Sheath (Chloropren-rubber), black, oil and abrasion resistant

Fire properties:
flame retardant

Test certificate:

Cert
.....
..

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

3G1

20.0

2 X 1.5

.
..

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

9.5

30

120

500 Sp, 1000 Sp

13.7

9.5

30

130

500 Sp, 1000 Sp

3 G 1.5

13.7

10.5

45

150

100 R, 500 Sp, 1000 Sp

4 G 1.5

13.7

11.5

60

190

100 R, 500 Sp, 1000 Sp

5 G 1.5

13.7

12.5

75

230

100 R, 500 Sp, 1000 T

2 X 2.5

8.21

11.5

50

190

500 Sp, 1000 Sp

3 G 2.5

8.21

12.5

75

220

100 R, 500 Sp, 1000 T

4 G 2.5

8.21

14.0

100

280

100 R, 500 Sp, 1000 T

H07RNF

5 G 2.5

8.21

15.5

125

340

100 R, 500 Sp, 1000 T

2X4

5.09

13.5

80

240

500 T, 1000 T

3G4

5.09

14.5

120

305

500 T, 1000 T

4G4

5.09

16.0

160

390

500 T, 1000 T

5G4

5.09

17.5

200

470

500 T, 1000 T

2X6

3.39

15.0

120

290

500 T, 1000 T

3G6

3.39

16.0

180

495

500 T, 1000 T

4G6

3.39

17.5

240

520

500 T, 1000 T

5G6

3.39

19.0

300

640

500 T, 1000 T

3 G 10

1.95

22.0

300

880

500 T, 1000 T

4 G 10

1.95

24.0

400

950

500 T, 1000 T

5 G 10

1.95

26.0

500

1,150

500 T, 1000 T

Page 24

- >> RUBBER ENERGY CABLES

SKW | PRAKAB | Products

H07RNF (GMSu) / A07RNF (GMSu)


Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

H07RNF
4 G 16

1.24

27.0

640

1,400

500 T, 1000 T

5 G 16

1.24

30.0

800

1,700

500 T, 1000 T

4 G 25

0.795

32.5

1,000

1,950

500 T, 1000 T

5 G 25

0.795

36.0

1,250

2,400

500 T, 1000 T

4 G 35

0.565

37.0

1,400

2,700

500 T, 1000 T

5 G 35

0.565

38.0

1,750

3,000

500 T, 1000 T

4 G 50

0.393

42.0

2,000

3,600

500 T

5 G 50

0.393

50.0

2,500

4,390

500 T

4 G 70

0.277

49.5

2,800

4,900

500 T

4 G 95

0.21

55.5

3,800

6,200

500 T

4 G 120

0.164

60.0

4,800

7,800

500 T

4 G 150

0.132

65.0

6,000

9,700

500 T

1 x 1.5

13.7

6.5

15

55

500 T, 1000 T

1 x 2.5

8.21

7.0

25

85

500 T, 1000 T

1X4

5.09

8.0

40

105

500 T, 1000 T

1X6

3.39

9.0

60

140

500 T, 1000 T

1 X 10

1.95

11.0

100

210

500 T, 1000 T

1 X 16

1.24

12.0

160

290

500 T, 1000 T

1 X 25

0.795

13.5

250

410

500 T, 1000 T

1 X 35

0.565

16.0

350

560

500 T, 1000 T

1 X 50

0.393

17.6

500

740

500 T, 1000 T

1 X 70

0.277

21.0

700

1,050

500 T, 1000 T

1 X 95

0.21

23.0

950

1,300

500 T, 1000 T

1 X 120

0.164

25.0

1,200

1,560

500 T, 1000 T

1 X 150

1.132

28.0

1,500

2,000

500 T, 1000 T

1 X 185

0.108

31.0

1,850

2,300

500 T, 1000 T

1 X 240

0.0817

34.0

2,400

3,000

500 T, 1000 T

A07RNF
7 G 1.5

13.7

15.5

105

330

500 T, 1000 T

9 G 1.5

13.7

17.0

135

428

500 T, 1000 T

12 G 1.5

13.7

20.0

180

470

500 T, 1000 T

19 G 1.5

13.7

23.0

285

620

500 T, 1000 T

24 G 1.5

13.7

27.0

360

870

500 T, 1000 T

27 G 1.5

13.7

27.0

405

1,077

500 T, 1000 T

7 G 2.5

8.21

17.5

175

470

500 T, 1000 T

12 G 2.5

8.21

23.0

300

650

500 T, 1000 T

19 G 2.5

8.21

28.0

475

1,100

500 T, 1000 T

24 G 2.5

8.21

32.5

600

1,260

500 T, 1000 T

7G4

5.090

20.0

280

703

500 T, 1000 T

12 G 4

5.090

26.5

480

1,020

500 T, 1000 T

Subject to technical changes.

Page 25

- >> PVC - CONTROL AND ELECTRONIC CABLES

SKW | PRAKAB | Products

YSLY / YSLY (SKWControlflex)


Control cable, unscreened
Standard: SKW-internal standard adapted to
VE and VDE
Usage:
For the electrical connection of components of production machines and machine tools. Shows some resistance to all-purpose
mineral oil and is not designed for permanent usage in oil baths.
The cable is designed for use in buildings and should be laid with
mechanical protection.

Rated voltage:

300/500 V

Test voltage:

until 1 mm2: 1500 Veff


above 1 mm2: 2000 Veff

Temperature range:
laying temperature:
min. +5 C
operating temperature: fixed 40 C to +50 C
in motion 5 C to +50 C
conductor temperature: max. +60 C
short-circuit
temperature:
max. +150 C/5 s
Bending radius (min.): 4 x of cable

3
2
1
Construction:
1 Copper conductor, fine wire
2 Core insulation (PVC), cores stranded in layers
3 Sheath (PVC grey RAL 7001 or blue RAL 5012 for intrinsically safe
installations), partially oil resistant

Core identification:
black with number printing, protective conductor green/yellow (outer layer)
Fire properties:
flame retardant

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

(EN 50265-2-1,
IEC 60332-1)

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

YSLYOZ
2 x 0.5

39.000

4.8

10

36

100 R, 500 Sp

2 x 0.75

26.000

5.2

15

44

100 R, 500 Sp

2x1

19.500

5.5

20

51

100 R, 500 Sp

2 x 1.5

13.300

6.3

30

69

100 R, 500 Sp

2 x 2.5

7.980

7.6

50

106

100 R, 500 Sp

3 x 0.5

39.000

5.0

15

42

100 R, 500 Sp

4 x 0.5

39.000

5.7

20

55

100 R, 500 Sp

5 x 0.5

39.000

6.2

25

65

100 R, 500 Sp

YSLYJZ

7 x 0.5

39.000

6.7

35

81

100 R, 500 Sp

10 x 0.5

39.000

8.8

50

129

500 Sp, 1000 Sp

12 x 0.5

39.000

9.0

60

142

100 R, 500 Sp

14 x 0.5

39.000

9.5

70

158

500 Sp, 1000 Sp

16 x 0.5

39.000

10.0

80

176

500 Sp, 1000 Sp

18 x 0.5

39.000

10.7

90

202

500 Sp, 1000 Sp

21 x 0.5

39.000

11.3

105

229

500 T, 1000 T

25 x 0.5

39.000

12.9

125

284

500 T, 1000 T

30 x 0.5

39.000

13.5

150

330

500 T, 1000 T

Page 26

SKW | PRAKAB | Products

- >> PVC - CONTROL AND ELECTRONIC CABLES

YSLY / YSLY (SKWControlflex)


Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

YSLYJZ
34 x 0.5

39.000

14.5

170

375

500 T, 1000 T

40 x 0.5

39.000

15.0

200

410

500 T, 1000 T

50 x 0.5

39.000

17.0

250

520

500 T, 1000 T

61 x 0.5

39.000

19.5

305

620

500 T, 1000 T

3 x 0.75

26.000

5.4

23

53

100 R, 500 Sp

4 x 0.75

26.000

6.2

30

68

100 R, 500 Sp

5 x 0.75

26.000

6.8

38

83

100 R, 500 Sp

6 x 0.75

26.000

7.0

45

99

500 Sp, 1000 Sp

7 x 0.75

26.000

7.3

53

104

100 R, 500 Sp

10 x 0.75

26.000

9.6

75

165

500 Sp, 1000 Sp

12 x 0.75

26.000

9.9

90

183

100 R, 500 Sp

16 x 0.75

26.000

11.4

120

240

500 T, 1000 T

18 x 0.75

26.000

11.9

135

267

500 T, 1000 T

21 x 0.75

26.000

12.8

158

303

500 T, 1000 T

25 x 0.75

26.000

14.3

188

376

500 T, 1000 T

34 x 0.75

26.000

16.3

255

496

500 T, 1000 T

41 x 0.75

26.000

18.3

308

620

500 T, 1000 T

50 x 0.75

26.000

19.2

375

698

500 T, 1000 T

61 x 0.75

26.000

20.5

458

790

500 T, 1000 T

80 x 0.75

26.000

23.0

600

1,000

500 T, 1000 T

3x1

19.500

5.9

30

64

100 R, 500 Sp

4x1

19.500

6.5

40

80

100 R, 500 Sp

5x1

19.500

7.2

50

99

100 R, 500 Sp

7x1

19.500

8.0

70

127

100 R, 500 Sp

10 x 1

19.500

11.5

100

200

500 T, 1000 T

12 x 1

19.500

10.8

120

223

500 T, 1000 T

14 x 1

19.500

11.3

140

249

500 T, 1000 T

16 x 1

19.500

12.0

160

286

500 T, 1000 T

18 x 1

19.500

12.7

180

316

500 T, 1000 T

21 x 1

19.500

13.6

210

369

500 T, 1000 T

25 x 1

19.500

14.5

250

456

500 T, 1000 T

30 x 1

19.500

16.4

300

530

500 T, 1000 T

34 x 1

19.500

17.4

340

591

500 T, 1000 T

50 x 1

19.500

20.9

500

855

500 T, 1000 T

61 x 1

19.500

24.0

610

1,050

500 T, 1000 T

3 x 1.5

13.300

6.6

45

84

100 R, 500 Sp

4 x 1.5

13.300

7.3

60

105

100 R, 500 Sp

5 x 1.5

13.300

8.2

75

132

100 R, 500 Sp

6 x 1.5

13.300

8.5

90

158

500 Sp, 1000 Sp

7 x 1.5

13.300

8.9

105

168

500 T, 1000 T

Page 27

- >> PVC - CONTROL AND ELECTRONIC CABLES

SKW | PRAKAB | Products

YSLY / YSLY (SKWControlflex)


Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

YSLYJZ
10 x 1.5

13.300

11.6

150

263

500 T, 1000 T

12 x 1.5

13.300

12.0

180

294

500 T, 1000 T

14 x 1.5

13.300

12.8

210

336

500 T, 1000 T

16 x 1.5

13.300

13.5

240

377

500 T, 1000 T

18 x 1.5

13.300

14.4

270

426

500 T, 1000 T

21 x 1.5

13.300

15.2

315

488

500 T, 1000 T

25 x 1.5

13.300

17.5

375

612

500 T, 1000 T

32 x 1.5

13.300

18.5

480

700

500 T, 1000 T

34 x 1.5

13.300

19.7

510

795

500 T, 1000 T

42 x 1.5

13.300

22.2

630

999

500 T, 1000 T

50 x 1.5

13.300

23.6

750

1,148

500 T, 1000 T

61 x 1.5

13.300

27.0

915

1,450

500 T, 1000 T

3 x 2.5

7.980

8.1

75

132

100 R, 500 Sp

4 x 2.5

7.980

9.0

100

167

100 R, 500 Sp

5 x 2.5

7.980

10.1

125

211

100 R, 500 Sp

7 x 2.5

7.980

11.2

175

273

500 T, 1000 T

10 x 2.5

7.980

14.4

250

417

500 T, 1000 T

12 x 2.5

7.980

15.1

300

475

500 T, 1000 T

16 x 2.5

7.980

17.1

400

617

500 T, 1000 T

18 x 2.5

7.980

18.0

450

688

500 T, 1000 T

25 x 2.5

7.980

22.1

625

993

500 T, 1000 T

34 x 2.5

7.980

30.0

850

1,384

500 T, 1000 T

50 x 2.5

7.980

32.5

1,250

1,860

500 T, 1000 T

3x4

4.950

9.9

120

205

500 T, 1000 T

4x4

4.950

11.2

160

263

500 T, 1000 T

5x4

4.950

12.6

200

332

500 T, 1000 T

7x4

4.950

13.7

280

422

500 T, 1000 T

3x6

3.300

11.2

180

278

500 T, 1000 T

4x6

3.300

12.6

240

358

500 T, 1000 T

5x6

3.300

14.1

300

453

500 T, 1000 T

7x6

3.300

15.6

420

587

500 T, 1000 T

4 x 10

1.910

16.5

400

620

500 T, 1000 T

5 x 10

1.910

18.4

500

778

500 T, 1000 T

7 x 10

1.910

20.1

700

1,001

500 T, 1000 T

4 x 16

1.210

19.6

640

938

500 T, 1000 T

5 x 16

1.210

21.9

800

1,178

500 T, 1000 T

7 x 16

1.210

23.9

1,120

1,518

500 T, 1000 T

4 x 25

0.780

27.0

1,000

1,590

500 T, 1000 T

5 x 25

0.780

30.0

1,250

2,000

500 T, 1000 T

7 x 25

0.780

38.0

1,750

2,560

500 T, 1000 T

Page 28

- >> PVC - CONTROL AND ELECTRONIC CABLES

SKW | PRAKAB | Products

YSLY / YSLY (SKWControlflex)


Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

YSLYJZ
4 x 35

0.554

29.0

1,400

2,110

500 T, 1000 T

5 x 35

0.554

33.0

1,750

2,635

500 T, 1000 T

4 x 50

0.368

35.0

2,000

2,950

500 T, 1000 T

4 x 70

0.272

40.0

2,800

4,254

500 T, 1000 T

Subject to technical changes.

Page 29

- >> PVC - CONTROL AND ELECTRONIC CABLES

SKW | PRAKAB | Products

YSLCY / YSLCY (SKWControlflexC)


Control cable, screened
Standard: SKW-internal standard adapted to
VE and VDE
Usage:
For the electrical connection of components of production machines and machine tools if a certain amount of electronic screening
is required. Shows some resistance to all-purpose mineral oil and
is not designed for permanent usage in oil baths. The cable is designed for use within buildings and should be installed with mechanical protection.

Rated voltage:

300/500 V

Test voltage:

until 1 mm2: 1500 Veff


above 1 mm2: 2000 Veff

Temperature range:
laying temperature:
min. +5 C
operating temperature: fixed 40 C to +50 C
in motion 5 C to +50 C
conductor temperature: max. +60 C
short-circuit
temperature:
max. +150 C/5 s
Bending radius (min.): 4 x of cable

Core identification:
black with number printing, protective
conductor green/yellow (outer layer)

Construction:
1 Copper conductor, fine wire
2 Core insulation (PVC), cores stranded in layers
3 Inner covering (plastic tape)
4 Braided screen (tinned copper wires)
5 Sheath (PVC grey RAL 7001 or blue RAL 5012 for intrinsically safe
installations), partially oil resistant

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Fire properties:
flame retardant

(EN 50265-2-1,
IEC 60332-1)

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

YSLCYOZ
2 x 0.5

39

5.8

36

48

100 R, 500 Sp

2 x 0.75

26

6.0

43

53

100 R, 500 Sp

2x1

19.5

6.5

51

63

100 R, 500 Sp

2 x 1.5

13.3

7.7

65

87

100 R, 500 Sp

2 x 2.5

7.98

9.1

92

123

100 R, 500 Sp

YSLCYJZ
3 x 0.5

39

6.1

43

56

500 Sp, 1000 Sp

4 x 0.5

39

6.7

49

68

100 R, 500 Sp

5 x 0.5

39

7.3

57

80

500 Sp, 1000 Sp

7 x 0.5

39

7.9

69

100

500 Sp, 1000 Sp

10 x 0.5

39

10.0

92

143

500 Sp, 1000 Sp

12 x 0.5

39

10.4

104

160

500 Sp, 1000 Sp

14 x 0.5

39

11.0

116

180

500 Sp, 1000 Sp

16 x 0.5

39

11.5

129

202

500 Sp, 1000 Sp

21 x 0.5

39

12.8

159

252

500 T, 1000 T

25 x 0.5

39

14.5

211

318

500 T, 1000 T

30 x 0.5

39

15.3

238

363

500 T, 1000 T

34 x 0.5

39

16.3

170

420

500 T, 1000 T

Page 30

- >> PVC - CONTROL AND ELECTRONIC CABLES

SKW | PRAKAB | Products

YSLCY / YSLCY (SKWControlflexC)


Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

YSLCYJZ
40 x 0.5

39

17.3

297

465

500 T, 1000 T

50 x 0.5

39

19.6

362

575

500 T, 1000 T

61 x 0.5

39

20.8

424

675

500 T, 1000 T

3 x 0.75

26

7.0

52

65

100 R, 500 Sp

4 x 0.75

26

9.5

61

79

100 R, 500 Sp

5 x 0.75

26

7.6

72

95

100 R, 500 Sp

7 x 0.75

26

8.2

89

120

100 R, 500 Sp

8 x 0.75

26

9.0

100

134

500 Sp, 1000 Sp

10 x 0.75

26

10.5

121

168

500 Sp, 1000 Sp

12 x 0.75

26

10.9

138

190

500 Sp, 1000 Sp

16 x 0.75

26

12.1

174

241

500 Sp, 1000 Sp

18 x 0.75

26

12.7

444

268

500 T, 1000 T

21 x 0.75

26

13.7

237

319

500 T, 1000 T

25 x 0.75

26

15.2

280

377

500 T, 1000 T

34 x 0.75

26

17.0

357

497

500 T, 1000 T

44 x 0.75

26

19.2

448

600

500 T, 1000 T

50 x 0.75

26

20.6

496

695

500 T, 1000 T

61 x 0.75

26

23.0

619

720

500 T, 1000 T

3x1

19.5

6.9

62

76

100 R, 500 Sp

4x1

19.5

7.5

74

94

100 R, 500 Sp

5x1

19.5

8.2

88

110

100 R, 500 Sp

7x1

19.5

8.9

112

141

100 R, 500 Sp

10 x 1

19.5

11.4

152

202

500 T, 1000 T

12 x 1

19.5

11.8

174

232

500 T, 1000 T

14 x 1

19.5

12.4

217

259

500 T, 1000 T

16 x 1

19.5

13.0

241

305

500 T, 1000 T

18 x 1

19.5

14.2

268

342

500 T, 1000 T

21 x 1

19.5

15.0

302

386

500 T, 1000 T

25 x 1

19.5

17.0

354

464

500 T, 1000 T

30 x 1

19.5

17.6

407

530

500 T, 1000 T

34 x 1

19.5

19.1

458

604

500 T, 1000 T

50 x 1

19.5

22.6

671

849

500 T, 1000 T

3 x 1.5

13.3

8.1

82

106

100 R, 500 Sp

4 x 1.5

13.3

8.9

100

131

100 R, 500 Sp

5 x 1.5

13.3

9.5

119

156

100 R, 500 Sp

7 x 1.5

13.3

10.7

154

203

100 R, 500 Sp

8 x 1.5

13.3

11.7

172

227

500 T, 1000 T

10 x 1.5

13.3

14.0

236

310

500 T, 1000 T

12 x 1.5

13.3

13.5

268

341

500 T, 1000 T

14 x 1.5

13.3

15.3

302

389

500 T, 1000 T

Page 31

- >> PVC - CONTROL AND ELECTRONIC CABLES

SKW | PRAKAB | Products

YSLCY / YSLCY (SKWControlflexC)


Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

YSLCYJZ
16 x 1.5

13.3

16.1

338

438

500 T, 1000 T

18 x 1.5

13.3

17.1

373

490

500 T, 1000 T

21 x 1.5

13.3

18.1

422

553

500 T, 1000 T

25 x 1.5

13.3

20.6

530

667

500 T, 1000 T

32 x 1.5

13.3

22.3

645

817

500 T, 1000 T

34 x 1.5

13.3

23.2

686

874

500 T, 1000 T

44 x 1.5

13.3

26.5

899

1,139

500 T, 1000 T

50 x 1.5

13.3

27.8

1,001

1,269

500 T, 1000 T

61 x 1.5

13.3

29.4

1,183

1,490

500 T, 1000 T

3 x 2.5

7.98

9.0

119

148

500 T, 1000 T

4 x 2.5

7.98

10.7

149

190

500 T, 1000 T

5 x 2.5

7.98

11.0

179

222

500 T, 1000 T

7 x 2.5

7.98

12.8

254

298

500 T, 1000 T

10 x 2.5

7.98

16.8

353

454

500 T, 1000 T

12 x 2.5

7.98

17.4

407

519

500 T, 1000 T

18 x 2.5

7.98

20.6

610

747

500 T, 1000 T

50 x 2.5

7.98

32.9

1,553

1,898

500 T, 1000 T

3x4

4.95

10.9

172

207

500 T, 1000 T

4x4

4.95

12.0

239

251

500 T, 1000 T

5x4

4.95

13.5

288

340

500 T, 1000 T

7x4

4.95

14.8

378

442

500 T, 1000 T

4x6

3.3

14.3

334

384

500 T, 1000 T

5x6

3.3

15.7

403

472

500 T, 1000 T

7x6

3.3

17.3

534

604

500 T, 1000 T

4 x 10

1.91

20.0

518

683

500 T, 1000 T

5 x 10

1.91

22.1

662

824

500 T, 1000 T

7 x 10

1.91

24.4

882

1079

500 T, 1000 T

4 x 16

1.21

22.0

809

930

500 T, 1000 T

5 x 16

1.21

26.2

990

1,203

500 T, 1000 T

7 x 16

1.21

28.8

1,370

1,587

500 T, 1000 T

Subject to technical changes.

Page 32

- >> PVC - CONTROL AND ELECTRONIC CABLES

SKW | PRAKAB | Products

JEY(St)Y...Bd
Control Cable for industrial electronics
Standard: DIN VDE 0815
Usage:
For use in the electronics of control and regulating equipment.
Preferably for use in interior premises but also for fixed installation
on exterior walls of buildings. Not suitable for high-current installation purposes and direct burial.

Rated voltage:

max. 225 Vss

Test voltage:
core/core
core/screen

500 Veff
2000 Veff

Temperature range:
laying temperature:
operating temperature:

min. 5 C
fixed 30 C to +70 C
in motion 5 C to +50 C

Bending radius (min.): 7.5 x of cable


5

Construction:
1 Copper conductor, single wire
2 Core insulation (PVC), conductors pair stranded, pairs stranded
in groups
3 Inner covering (plastic tape)
4 Screen (plastic laminated aluminium tape with drain wire)
5 Sheath (PVC grey RAL 7032)

Cert
.....
..

.
..

Core identification:

DIN VDE 0815


(BdSi, BdZ)

Test certificate:

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Electrical parameters
Conductor diameter
loop restistance, max. at 20 C

(/km)

73.2
100

(nF/km)

100

(pF/100 m)

200

Mutual capacitance, max. at 800 Hz

Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

2 x 2 x 0.8

7.0

4 x 2 x 0.8

9.0

Metal
weight
(kg/km)

0.8

(M.km)

Insulation resistance, min. at 20 C

Capacitance unbalance K, max. at 800 Hz

(mm)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

25

60

500 T, 1000 T

45

100

500 T, 1000 T

JEY (St)YBd

8 x 2 x 0.8

11.5

85

165

500 T, 1000 T

12 x 2 x 0.8

14.0

126

245

500 T, 1000 T

16 x 2 x 0.8

15.5

166

305

500 T, 1000 T

20 x 2 x 0.8

16.0

206

360

500 T, 1000 T

24 x 2 x 0.8

17.0

246

440

500 T, 1000 T

32 x 2 x 0.8

21.0

327

560

500 T, 1000 T

40 x 2 x 0.8

23.0

407

675

500 T, 1000 T

80 x 2 x 0.8

31.0

809

1,295

500 T, 1000 T

Subject to technical changes.

Page 33

- >> INSULATED OVERHEAD LINES

SKW | PRAKAB | Products

1AES
PE insulated bundled overhead line
Standard: TP PRAKAB 02/03
Usage:
Can be used for fixed installation as overhead power lines up to
1000 V inclusive. Not suitable for direct burial.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
50 C to +90 C
max. +90 C
max. +200 C/5 s

Bending radius (min.): 18 x core-


2

1
Core identification:
1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral conductor is smooth and marked with earth markings

Construction:
1 Aluminium conductor with increased breaking load, round stranded
compacted (RM)
2 Core insulation (PE black, UV- resistant); 2 or 4 cores of equal cross
section are stranded together in right-hand lay, additionaly 1 or 2
cores of reduced cross section can be co-stranded

Test certificate:

Cert
.....
..

Number of cores x
nominal cross section
(mm2)

Max. conductor
resistance
(/km)

Min. breaking load of


conductor
strand
(kN)

Current rating in the


air1)
(A)

.. .. ...
.
.
.. . Sz JZD .
. . .

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

EZ Czech Republic,
EVP Slovak Republic,
GOST Russia
Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1-AES
2 x 16 RM

1.910

2.5

64

15.5

96

145

1000 T

4 x 16 RM

1.910

2.5

64

9.1

192

290

1000 T

1 x 25 RM

1.200

4.0

94

17.6

75

105

1000 T

2 x 25 RM

1.200

4.0

94

17.9

150

210

1000 T

4 x 25 RM

1.200

4.0

94

21.2

300

435

1000 T

4 x 25 + 25 RM/RM

1.200/1.200

4.0/4.0

94/94

24.6

375

315

1000 T

4 x 35 RM

0.868

5.5

113

24.1

420

525

1000 T

4 x 35 + 25 RM/RM

0.868/1.200

5.5/4.0

113/94

27.6

495

630

1000 T

4 x 50 RM

0.641

8.0

140

27.8

600

740

1000 T

4 x 50 + 25 RM/RM

0.641/1.200

8.0/4.0

140/94

29.6

675

845

1000 T

4 x 50 + 2 x 16 RM/RM

0.641/1.910

8.0/5.5

140/64

32.2

696

880

1000 T

4 x 70 RM

0.443

10.7

178

31.8

840

1,030

1000 T

4 x 70 + 25 RM/RM

0.443/1.200

10.7/4.0

178/94

33.3

915

1,150

1000 T

4 x 70 + 2 x 16 RM/RM

0.443/1.910

10.7/5.5

178/64

35.6

936

1,180

1000 T

4 x 95 RM

0.320

13.7

220

37.2

1,140

1,345

1000 T

4 x 95 + 25 RM/RM

0.320/1.200

13.7/4.0

220/94

38.1

1,215

1,450

1000 T

4 x 95 + 2 x 16 RM/RM

0.320/1.910

13.7/2.5

220/64

40.6

1,236

1,505

1000 T

4 x 120 RM

0.253

16.5

265

40.6

1,440

1,680

1000 T

4 x 120 + 25 RM/RM

0.253/1.200

16.5/4.0

265/94

41.6

1,515

1,765

1000 T

4 x 120 + 2 x 16 RM/RM

0.253/1.910

16.5/2.5

265/64

45.5

1,536

1,810

1000 T

1) basic rated current acc. to TP PRAKAB 02/03


Subject to technical changes.

Page 34

- >> INSULATED OVERHEAD LINES

SKW | PRAKAB | Products

EA2Y / EXA2Y
PE insulated bundled overhead line
Standard: VE/NORM E 8200-626 (HD 626)
Usage:
Can be used for fixed installation as overhead power lines up to
1000 V inclusive. Not suitable for direct burial.

Rated voltage:

0.6/1 kV

Test voltage:

3500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 20 C
40 C to +70 C
max. +70 C
max. +120 C/5 s

Bending radius (min.): 18 x core-


2

Construction:
1 Aluminium conductor with increased breaking load, round stranded
compacted (RM)
2 Core insulation (PE black, UV-resistant); 2 or 4 cores of equal cross
section are stranded together in right-hand lay, additionaly 1 or 2
cores of reduced cross section can be co-stranded

Number of cores x
nominal cross section
(mm2)

Max. conductor
resistance
(/km)

Min. breaking load of


conductor
strand
(kN)

Current rating in the


air1)
(A)

Core identification:
1, 2 resp. 3 raised longitudinal ribs on the surface of the cores; the 4. core is showing fine longitudinal grooves (75 % of surface) and is printed with the type designation

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

E-XA2Y
2 x 16 RM

1.910

64

2.74

14.2

94

131

500 T, 1000 T

4 x 16 RM

1.910

64

2.74

17.1

188

271

500 T, 1000 T

2 x 25 RM

1.200

94

4.5

17.2

147

197

500 T, 1000 T

4 x 25 RM

1.200

94

4.5

22.0

294

407

500 T, 1000 T

4 x 35 RM

0.868

113

5.60

24.3

412

533

500 T, 1000 T

E-A2Y

4 x 50 RM

0.641

140

7.70

28.0

588

705

500 T, 1000 T

4 x 50 + 25 RM/RM

0.641/1.200

140/94

7.70/4.05

30.0

662

827

500 T, 1000 T

4 x 70 RM

0.443

178

10.95

31.0

823

955

500 T, 1000 T

4 x 70 + 25 RM/RM

0.443/1.201

178/94

10.95/4.05

36.0

897

1,088

500 T, 1000 T

4 x 95 RM

0.320

220

15.15

36.0

1,117

1,280

500 T, 1000 T

4 x 95 + 25 RM/RM

0.320/1.202

220/94

15.15/4.05

39.0

1,191

1,398

500 T, 1000 T

1) basic rated current acc. to VE/NORM E 8200-626 (HD 626)


Subject to technical changes.

Page 35

- >> INSULATED OVERHEAD LINES

SKW | PRAKAB | Products

NFA2X
XLPE insulated bundled overhead line
Standard: VDE 0276626/A1
Usage:
Can be used for fixed installation as overhead power lines up to
1000 V inclusive. Not suitable for direct burial.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +80 C
max. +80 C
max. +130 C/5 s

Bending radius (min.): 18 x core-


2

Construction:
1 Aluminium conductor with increased breaking load, round stranded
compacted (RM)
2 Core insulation (PE black, UV-resistant); 2 or 4 cores of equal cross
section are stranded together in left-hand lay, additionaly 1 or 2 cores of reduced cross section can be co-stranded

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Min. breaking load of


conductor
strand
(kN)

Current rating in the


air1)
(A)

Core identification:
1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral conductor is smooth.
Test certificate:

Cert
.....
..

.
..

.. .. ...
Sz JZD .
. . ..
.

EZ Czech Republic,
VDE Germany,
BBJ Poland

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

NFA2X
4 x 25 RM

1.200

3.8

107

21.2

290

430

1000 T

4 x 35 RM

0.868

5.2

132

24.1

406

553

1000 T

4 x 50 RM

0.641

7.6

165

27.8

580

746

1000 T

4 x 70 RM

0.443

10.2

205

31.8

812

1,009

1000 T

4 x 70 + 1 x 35 RM/RM

0.443/0.868

10.2/5.2

205/132

36.2

914

1,150

1000 T

4 x 70 + 2 x 35 RM/RM

0.443/0.868

10.2/5.2

205/132

40.1

1,016

1,289

1000 T

Cross sections out of the range of the specifications


2 x 16 RM

1.910

2.3

72

15.6

93

147

1000 T

4 x 16 RM

1.910

2.3

72

18.8

186

286

1000 T

1 x 25 RM

1.910

3.8

107

9.0

73

106

1000 T

2 x 25 RM

1.200

3.8

107

18.0

145

208

1000 T

1 x 35 RM

0.868

5.2

132

10.0

102

135

1000 T

4 x 35 + 35 RM/RM

0.868/0.868

5.2/5.2

132/132

26.5

508

670

1000 T

1 x 50 RM

0.641

7.6

165

11.8

145

182

1000 T

2 x 50 RM

0.641

7.6

165

23.5

290

361

1000 T

3 x 50 RM

0.641

7.6

165

25.0

435

541

1000 T

4 x 50 + 25 RM/RM

0.641/1.200

7.6/3.8

165/107

31.9

653

814

1000 T

4 x 50 + 35 RM/RM

0.641/0.868

7.6/5.2

165/132

31.9

682

845

1000 T

1 x 70 RM

0.443

10.2

205

13.4

203

253

1000 T

4 x 70 + 25 RM/RM

0.443/1.200

10.2/3.8

205/107

36.0

885

1,105

1000 T

1 x 95 RM

0.320

13.5

240

15.4

276

333

1000 T

3 x 95 RM

0.320

13.5

240

33.2

827

999

1000 T

Page 36

- >> INSULATED OVERHEAD LINES

SKW | PRAKAB | Products

NFA2X
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Min. breaking load of


conductor
strand
(kN)

Current rating in the


air1)
(A)

4 x 95 RM

0.320

13.5

240

4 x 95 + 25 RM/RM

0.320/1.200

13.5/3.8

4 x 95 + 35 RM/RM

0.320/0.868

13.5/5.2

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

37.8

1,102

1,332

1000 T

240/107

41.8

1,175

1,438

1000 T

240/132

41.8

1.,204

1,467

1000 T

Cross sections out of the range of the specifications

1) basic rated current acc. to VDE 0276626/A1


Subject to technical changes.

Page 37

- >> INSULATED OVERHEAD LINES

SKW | PRAKAB | Products

AsXSn
XLPE insulated bundled overhead line,
flame retardant
Standard: TP PRAKAB 17/03

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Usage:
Can be used for fixed installation as overhead power lines
up to 1000 V inclusive. Not suitable for direct burial.

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +80 C
max. +80 C
max. +130 C/5 s

Bending radius (min.): 18 x core-

Core identification:
1, 2 resp. 3 raised longitudinal ribs on the surface
of the cores. The surface of the neutral conductor
is smooth and marked with earth markings.

Construction:
1 Aluminium conductor with increased breaking load, round stranded
compacted (RM)
2 Core insulation (XLPE black, UV-resistant, flame retardant). 2 or 4
cores of equal cross section are stranded together in right-hand lay,
additionaly 1 or 2 cores of reduced cross section can be co-stranded

Number of cores x
nominal cross section
(mm2)

Max.
conductor
resistance
(/km)

Min. breaking load of


conductor
strand
(kN)

Current rating
in the air
(A)

1 x 25 RM

1.200

4.0

94

1 x 35 RM

0.868

5.5

1 x 50 RM

0.641

8.0

1 x 70 RM

0.443

2 x 16 RM

1.910

2 x 25 RM

1.200

2 x 35 RM

0.868

4 x 16 RM
4 x 25 RM

Fire properties:
flame retardant
Test certificate:

Cert
.....
..

.
..

.. .. ...
Sz JZD .
. . ..
.

(EN 50265-2-1, IEC 60332-1)


EZ Czech Republic,
BBJ Poland

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

8.8

74

106

1000 T

113

9.8

103

135

1000 T

140

11.5

147

182

1000 T

10.7

178

13.1

206

253

1000 T

2.5

64

14.4

94

147

1000 T

4.0

94

17.6

147

208

1000 T

5.5

113

19.6

206

272

1000 T

1.910

2.5

64

17.4

188

286

1000 T

1.200

4.0

94

21.2

294

430

1000 T

4 x 35 RM

0.868

5.5

113

23.6

412

553

1000 T

4 x 50 RM

0.641

8.0

140

27.7

588

746

1000 T

4 x 70 RM

0.443

10.7

178

31.6

823

1,009

1000 T

AsXSn

4 x 95 RM

0.320

13.7

220

36.4

1,117

1,332

1000 T

4 x 120 RM

0.253

19.1

265

41.0

1,411

1,653

1000 T

4 x 35 + 1 x 25 RM/RM

0.868/1.200

5.5/4.0

113/94

26.5

485

640

1000 T

4 x 35 + 1 x 35 RM/RM

0.868/0.868

5.5/5.5

113/113

26.5

515

670

1000 T

4 x 50 + 1 x 25 RM/RM

0.641/1.200

8.0/4.0

140/94

31.1

662

814

1000 T

4 x 50 + 1 x 35 RM/RM

0.641/0.868

8.0/5.5

140/113

31.1

691

845

1000 T

4 x 70 + 1 x 25 RM/RM

0.443/1.200

10.7/4.0

178/94

35.4

897

1,105

1000 T

4 x 70 + 1 x 35 RM/RM

0.443/0.868

10.7/5.5

178/113

35.4

632

1,150

1000 T

4 x 95 + 1 x 25 RM/RM

0.320/1.200

13.7/4.0

220/94

40.8

1,191

1,438

1000 T

4 x 95 + 1 x 35 RM/RM

0.320/0.868

13.7/5.5

220/113

40.8

1,220

1,467

1000 T

4 x 120 + 1 x 25 RM/RM

0.253/1.200

19.1/4.0

265/94

45.9

1,485

1,786

1000 T

Page 38

- >> INSULATED OVERHEAD LINES

SKW | PRAKAB | Products

AsXSn
Number of cores x
nominal cross section
(mm2)

Max.
conductor
resistance
(/km)

Min. breaking load of


conductor
strand
(kN)

Current rating
in the air
(A)
ca.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

4 x 120 + 1 x 35 RM/RM

0.253/0.868

19.1/5.5

265/113

45.9

1,514

1,901

1000 T

4 x 50 + 2 x 25 RM/RM

0.641/1.200

8.0/4.0

140/94

34.5

735

941

1000 T

4 x 50 + 2 x 35 RM/RM
4 x 70 + 2 x 25 RM/RM

0.641/0.868

8.0/5.5

140/113

34.5

794

1,004

1000 T

0.443/1.200

10.7/4.0

178/94

39.3

970

1,196

1000 T

4 x 70 + 2 x 35 RM/RM

0.443/0.868

10.7/5.5

178/113

39.3

1,029

1,289

1000 T

4 x 95 + 2 x 25 RM/RM

0.320/1.200

13.7/4.0

220/94

45.3

1,265

1,527

1000 T

AsXSn

4 x 95 + 2 x 35 RM/RM

0.320/0.868

13.7/5.5

220/113

45.3

1,323

1,605

1000 T

4 x 120 + 2 x 25 RM/RM

0.253/1.200

19.1/4.0

265/94

51.0

1,558

1,915

1000 T

4 x 120 + 2 x 35 RM/RM

0.253/0.868

19.1/5.5

265/113

51.0

1,617

1,987

1000 T

1) basic rated current acc. to TP PRAKAB 17/03


Subject to technical changes.

Page 39

- >> INSULATED OVERHEAD LINES

SKW | PRAKAB | Products

PRALEX
XLPE insulated bundled overhead line
Standard: HD 626 S1
Usage:
Can be used for fixed installation as overhead power lines
up to 1000 V inclusive. Not suitable for direct burial.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

max. +130 C/5 s

Bending radius (min.): 12 x core- to 40 mm,


above:15 x core-

2 1

Construction:
1 Aluminium conductor (phase conductor), round stranded compacted (RM)
2 Alloy aluminium conductor 70 mm2 (neutral conductor, AlMgSi),
round stranded compacted (RM)
3 Core insulation (XLPE black, UV-resistant), 3 cores of equal
cross section stranded around neutral conducter in left hand
lay, additionally 1 or 2 cores of reduced cross section can be
co-stranded

Number
of cores x
nominal cross
section
(mm2)

min. 5 C
30 C to +90 C
max. +90 C

Max. conductor Max. conductor Current rating


resistance
resistance
in the air1)
phase
neutral
(A)
conductor
conductor
/km)
/km)
(
(

Core identification:
1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The protective core is smooth.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

PRALEX
3 x 35 + 70 RM

0.868

0.5

132

30

519

668

500 T, 1000 T

3 x 35 + 70 + 2 x 16 RM

0.868/1.91

0.5

132/72

35

613

790

500 T, 1000 T

3 x 50 + 70 RM

0.641

0.5

165

33

651

791

500 T, 1000 T

3 x 50 + 70 + 2 x 16 RM

0.641/1.91

0.5

165/72

37

745

920

500 T, 1000 T

3 x 70 + 70 RM

0.443

0.5

205

35

828

990

500 T, 1000 T

3 x 70 + 70 + 2 x 16 RM

0.443/1.91

0.5

205/72

39

922

1,120

500 T, 1000 T

3 x 70 + 70 + 2 x 25 RM

0.443/1.20

0.5

205/107

41

976

1,177

500 T, 1000 T

1) basic rated current acc. to HD 626 S1


Subject to technical changes.

Page 40

- >> INSULATED OVERHEAD LINES

SKW | PRAKAB | Products

AXKA
XLPE insulated bundled overhead line with bare neutral conductor
Standard: HD 626 S1 Part 6D
Usage:
Can be used for fixed installation as overhead power lines
up to 1000 V inclusive. Not suitable for direct burial.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 20 C
40 C to +90 C
max. +90 C
max. +250 C/5 s

Bending radius (min.): 20 x core-


3
2
1
Construction:
1 Aluminium conductor (phase conductor), round stranded
compacted (RM)
2 Bare alloy aluminium conductor (neutral conductor, AlMgSi), round
stranded compacted (RM)
3 Core insulation (XLPE black, UV-resistant), 3 cores of equal cross
section and the neutral conducter stranded together in right-hand
lay, additionally 1 core of reduced cross section can be co-stranded

Number
of cores x
nominal cross
section
(mm2)

Max. conduc- Min. breaking Current rating


tor
load of conducin the air1)
resistance
tor strand
(A)
/km)
(
(kN)

Core identification:
Raised longitudinal ribs on the surface of the
cores, the surface of one core is smooth with
type designation.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

AXKA
3 x 50/50 RM

0.641

165

27.5

580

681

500 T, 1000 T

3 x 50 + 25/50 RM

0.641/1.200

8.0/4.0

165/107

31

652

787

500 T, 1000 T

3 x 50 + 35/50 RM

0.641/0.868

8.0/5.5

165/132

31.5

682

818

500 T, 1000 T

3 x 95/95 RM

0.32

13.5

240

37

1,102

1,276

500 T, 1000 T

3 x 95 + 25/95 RM

0.641/1.200

13.5/4.0

240/107

41.3

1,175

1,382

500 T, 1000 T

3 x 95 + 35/95 RM

0.320/0.868

13.5/5.5

240/132

42

1,204

1,414

500 T, 1000 T

1) basic rated current acc. to HD 626 S1


Subject to technical changes.

Page 41

- >> INSULATED OVERHEAD LINES

SKW | PRAKAB | Products

25ADXK
XLPE- insulated medium voltage overhead line
Standard: TP PRAKAB 10/03
Usage:
Can be used for fixed installation as overhead power lines.
Not suitable for direct burial.

Rated voltage:

22 kV

Test voltage:

30.000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:
2

max. +200 C/5 s

1
Bending radius (min.): 12 x of cable

Construction:
1 Bare alloy aluminium conductor (AlMgSi), round stranded (RM)
2 Core insulation (XLPE, black, UV-resistant)

Number
Max. conductor Min. breaking
of cores x
resistance
load of
nominal cross
(/km)
conductor
section
strand
(mm2)
(kN)

min. 10 C
50 C to +90 C
max. +90 C

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

25ADXK
35 RM

0.967

9.5

200

12.2

105

142

1000 T

50 RM

0.690

13.5

245

13.4

150

192

1000 T

70 RM

0.507

19.0

310

15.1

210

249

1000 T

120 RM

0.285

33.5

430

18.3

360

412

1000 T

1) basic rated current acc. to TP PRAKAB 10/03


Subject to technical changes.

Page 42

- >> INSULATED OVERHEAD LINES

SKW | PRAKAB | Products

35ADXK
XLPE- insulated medium voltage overhead line
Standard: TP PRAKAB 18/03
Usage:
Can be used for fixed installation as overhead power lines.
Not suitable for direct burial.

Rated voltage:

35 kV

Test voltage:

40.000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:
2

min. 10 C
50 C to +90 C
max. +90 C
max. +200 C/5 s

Bending radius (min.): 12 x of cable

Construction:
1 Bare alloy aluminium conductor (AlMgSi), round stranded (RM)
2 Core insulation (XLPE, black, UV-resistant)

4
Number
Max. conductor Min. breaking
of cores x
resistance
load of
nominal cross
(/km)
conductor
section
strand
(mm2)
(kN)

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

35ADXK
35 RM

0.967

9.5

200

14.4

105

200

1000 T

50 RM

0.690

13.5

245

15.6

150

253

1000 T

70 RM

0.507

19.0

310

17.3

210

316

1000 T

120 RM

0.285

33.5

430

20.5

360

489

1000 T

1) basic rated current acc. to TP PRAKAB 18/03


Subject to technical changes.

Page 43

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

1CYKY
Underground cable with PVC insulation and PVC sheath
Standard: TP PRAKAB 01/03
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
50 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 15 x of cable

4
3
2
1
Construction:
1 Copper conductor, round solid (RE), round stranded (RM) resp.
sector-shaped stranded (SM)
2 Core insulation (PVC). Conductors stranded together.
3 Inner covering (EPDM or plastic tape)
4 Sheath (PVC black, UV-resistant)

Number of cores x
nominal cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

Current rating in the


air1)
(A)

coloured (HD 308 S2)

Fire properties:
flame retardant

(EN 50265-2-1, IEC 60332-1)

Test certificate:

Cert
.....
..

Core identification:

.
..

.. .. ...
Sz JZD .
. . ..
.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

EZ Czech Republic,
EVP Slovak Republic

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CYKY
4 x 25 RE

0.7520

134

101

22.4

980

1,341

1000 T

4 x 25 RM

0.7520

134

101

23.8

980

1,360

1000 T

5 x 25 RE

0.7520

134

101

24.5

1,225

1,622

1000 T

5 x 25 RM

0.7520

134

101

26.1

1,225

1,734

1000 T

3 x 35 + 25 RE/RE

0.5370/0.7520

161

126

22.4

1,274

1,646

1000 T

3 x 35 + 25 RM/RM

0.5370/0.7520

161

126

23.8

1,274

1.,776

1000 T

4 x 35 RE

0.5370

161

126

24.8

1,372

1,769

1000 T

4 x 35 RM

0.5370

161

126

26.2

1,372

1,809

1000 T

5 x 35 RE

0.5370

161

126

27.1

1,715

2,148

1000 T

5 x 35 RM

0.5370

161

126

28.8

1,715

2,239

1000 T

3 x 50 + 35 SM/RE

0.3870/0.5370

191

152

30.4

1,813

2,164

1000 T

3 x 50 + 35 SM/RM

0.3870/0.5370

191

152

30.4

1,813

2,059

1000 T

4 x 50 RM

0.3870

191

152

31.3

1,960

2,581

1000 T

4 x 50 SM

0.3870

191

152

30.4

1,960

2,355

1000 T

3 x 70 + 50 SM/RM

0.2680/0.3870

236

196

33.6

2,548

2,799

1000 T

4 x 70 RM

0.2680

236

196

35.8

2,744

3,503

1000 T

4 x 70 SM

0.2680

236

196

34.9

2,744

3,138

1000 T

3 x 95 + 50 SM/RM

0.2680/0.3870

280

238

37.5

3,283

3,599

1000 T

3 x 95 + 70 SM/RM

0.1980/0.2680

280

238

39.3

3,479

3,937

1000 T

4 x 95 RM

0.1980

280

238

41.3

3,724

4,727

1000 T

4 x 95 SM

0.1980

280

238

39.3

3,724

4,205

1000 T

3 x 120 + 50 SM/RM

0.1570/0.3870

317

276

40.0

4,018

4,264

500 T

Page 44

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

1CYKY
Number of cores x
nominal cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

Current rating in the


air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CYKY
3 x 120 + 70 SM/RM

0.1570/0.2680

317

276

43.0

4,214

4,427

500 T

4 x 120 SM

0.1570

317

276

43.0

4,704

5,243

500 T

3 x 150 + 70 SM/RM

0.1240/0.2680

359

319

46.8

5,096

5,347

500 T

4 x 150 SM

0.1240

359

319

46.8

5,880

6,611

500 T

3 x 185 + 95 SM/RM

0.1020/0.1980

401

364

49.8

6,370

6,771

500 T

4 x 185 SM

0.1020

401

364

49.8

7,252

8,021

500 T

3 x 240 + 120 SM/RM

0.0783/0.1570

464

430

56.4

8,232

8,563

500 T

4 x 240 SM

0.0783

464

430

56.4

9,408

9,686

500 T

1) basic rated current acc. to TP PRAKAB 01/03


Subject to technical changes.

Page 45

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EYY
Underground cable with PVC insulation and PVC sheath
Standard: VE K 23 and K 603 (HD 603)
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

4
3
2
1
Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM or plastic tape) in case of multicore
constructions
4 Sheath (PVC black, UV-resistant)

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

1 x 10 RM

1.8300

83

Rated voltage:

0.6/1 kV

Test voltage:

3500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

.....
..

15 x of cable (single core)


12 x of cable (multi core)

Core identification:

coloured (HD 308 S2)

Test certificate:

Current rating in the


air1)
(A)

.
..

max. +160 C/5 s


(< 300 mm2)
resp. max. +140 C/5 s
(> 300 mm2)

Biegeradius (mind.)

Fire properties:
flame retardant

Cert

min. 5 C
5 C to +50 C
max. +70 C

(EN 50265-2-1,
IEC 60332-1)
VE Austria

.. .. ...
Sz JZD .
. . ..
.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

8.8

100

153

500 T, 1000 T

EYY0
64

1 x 16 RE

1.1500

107

84

9.4

160

219

500 T, 1000 T

1 x 16 RM

1.1500

107

84

9.8

160

223

500 T, 1000 T

1 x 25 RM

0.7270

138

114

11.3

250

329

500 T, 1000 T

1 x 35 RM

0.5240

164

139

12.4

350

435

500 T, 1000 T

1 x 50 RM

0.3870

195

169

14.9

500

575

500 T, 1000 T

1 x 70 RM

0.2680

238

213

17.0

700

793

500 T, 1000 T

1 x 95 RM

0.1930

286

264

19.0

950

1,088

500 T, 1000 T

1 x 120 RM

0.1530

325

307

20.0

1,200

1,319

500 T, 1000 T

1 x 150 RM

0.1240

366

352

22.5

1,500

1,571

500 T, 1000 T

1 x 185 RM

0.0991

413

406

24.5

1,850

1,941

500 T, 1000 T

1 x 240 RM

0.0754

479

483

28.0

2,400

2,558

500 T, 1000 T

1 x 300 RM

0.0601

539

552

30.0

3,000

3,164

500 T, 1000 T

1 x 400 RM

0.0470

614

646

35.0

4,000

4,112

500 T, 1000 T

1 x 500 RM

0.0366

693

747

38.5

5,000

5,128

500 T, 1000 T

8.8

100

153

500 T, 1000 T

EYYJ
1 x 10 RM

1.8300

83

64

1 x 16 RE

1.1500

107

84

9.4

160

219

500 T, 1000 T

1 x 16 RM

1.1500

107

84

9.8

160

223

500 T, 1000 T

Page 46

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EYY
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

1 x 25 RM

0.7270

138

1 x 35 RM

0.5240

1 x 50 RM

0.3870

1 x 70 RM

Current rating in the


air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Gesamt
gewicht
(kg/km) ca.

Standard
lenghts/
packing
(m)

114

11.3

250

329

500 T, 1000 T

164

139

12.4

350

435

500 T, 1000 T

195

169

14.9

500

575

500 T, 1000 T

0.2680

238

213

17.0

700

793

500 T, 1000 T

EYYJ

1 x 95 RM

0.1930

286

264

19.0

950

1,088

500 T, 1000 T

1 x 120 RM

0.1530

325

307

20.0

1,200

1,319

500 T, 1000 T

1 x 150 RM

0.1240

366

352

22.5

1,500

1,571

500 T, 1000 T

1 x 185 RM

0.0991

413

406

24.5

1,850

1,941

500 T, 1000 T

1 x 240 RM

0.0754

479

483

28.0

2,400

2,558

500 T, 1000 T

1 x 300 RM

0.0601

539

552

30.0

3,000

3,164

500 T, 1000 T

1 x 400 RM

0.0470

614

646

35.0

4,000

4,112

500 T, 1000 T

1 x 500 RM

0.0366

693

747

38.5

5,000

5,128

500 T, 1000 T

EYYO
2 x 1.5 RE

12.1000

32

20

8.4

30

119

500 Sp, 1000 Sp

2 x 2.5 RE

7.4100

42

27

9.6

50

146

500 Sp, 1000 Sp

2 x 4 RE

4.6100

54

37

10.5

80

247

500 Sp, 1000 Sp

2 x 6 RE

3.0800

68

48

11.6

120

262

500 Sp, 1000 Sp

2 x 10 RE

1.8300

90

66

13.5

200

387

500 T, 1000 T

2 x 16 RE

1.1500

116

89

17.1

320

588

500 T, 1000 T

3 x 1.5 RE

12.1000

27

19.5

9.1

45

138

500 Sp, 1000 Sp

4 x 1.5 RE

12.1000

27

19.5

9.7

60

160

500 Sp, 1000 Sp

5 x 1.5 RE

12.1000

19

14.5

10.5

75

187

500 Sp, 1000 Sp

3 x 2.5 RE

7.4100

36

25

9.8

75

182

500 Sp, 1000 Sp

4 x 2.5 RE

7.4100

36

25

10.4

100

214

500 Sp, 1000 Sp

5 x 2.5 RE

7.4100

25

19.5

12.0

125

261

500 Sp, 1000 Sp

3 x 4 RE

4.6100

46

34

11.2

120

260

500 Sp, 1000 Sp

4 x 4 RE

4.6100

46

34

13.0

160

321

500 Sp, 1000 Sp

5 x 4 RE

4.6100

32

25.5

14.5

200

388

500 Sp, 1000 Sp

3 x 6 RE

3.0800

58

43

12.5

180

338

500 Sp, 1000 Sp

4 x 6 RE

3.0800

58

43

14.0

240

421

500 Sp, 1000 Sp

5 x 6 RE

3.0800

41

32

15.7

300

510

500 Sp, 1000 Sp

3 x 10 RE

1.8300

78

59

15.6

300

506

500 T, 1000 T

4 x 10 RE

1.8300

78

59

17.0

400

632

500 T, 1000 T

5 x 10 RE

1.8300

55

44

19.0

500

779

500 T, 1000 T

4 x 10 RM

1.8300

78

59

17.0

400

654

500 T, 1000 T

5 x 10 RM

1.8300

55

44

19.0

500

791

500 T, 1000 T

3 x 16 RE

1.1500

101

78

17.5

480

718

500 T, 1000 T

4 x 16 RE

1.1500

101

78

19.3

640

912

500 T, 1000 T

5 x 16 RE

1.1500

71

59

21.0

800

1,147

500 T, 1000 T

EYYO/EYYJ/EYYJN

Page 47

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EYY
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

3 x 16 RM

1.1500

101

4 x 16 RM

1.1500

5 x 16 RM

1.1500

3 x 25 RM

Current rating in the


air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

78

18.9

480

762

500 T, 1000 T

101

78

20.2

640

957

500 T, 1000 T

71

59

22.2

800

1,143

500 T, 1000 T

0.7270

132

105

21.5

750

1,188

500 T, 1000 T

4 x 25 RM

0.7270

132

105

24.7

1,000

1,427

500 T, 1000 T

5 x 25 RM

0.7270

28.4

1,250

1,761

500 T, 1000 T

3 x 35 SM

0.0524

159

129

22.5

1,050

1,231

500 T, 1000 T

4 x 35 SM

0.0524

159

129

24.5

1,400

1,609

500 T, 1000 T

EYYO/EYYJ/EYYJN

5 x 35 RM

0.0524

30.0

1,750

2,298

500 T, 1000 T

3 x 50 SM

0.3870

188

157

25.9

1,500

1,688

500 T, 1000 T

4 x 50 SM

0.3870

188

157

28.5

2,000

2,149

500 T, 1000 T

5 x 50 RM

0.3870

36.5

2,500

3,200

500 T, 1000 T

3 x 70 SM

0.2680

232

199

29.5

2,100

2,450

500 T, 1000 T

4 x 70 SM

0.2680

232

199

32.2

2,800

2,941

500 T, 1000 T

5 x 70 RM

0.2680

43.0

3,500

4,337

500 T, 1000 T

3 x 95 SM

0.1930

280

246

33.0

2,850

3,210

500 T, 1000 T

4 x 95 SM

0.1930

280

246

37.5

3,800

4,103

500 T, 1000 T

5 x 95 RM

0.1930

50.0

4,750

6,090

500 T, 1000 T

3 x 120 SM

0.1530

318

285

36.0

3,600

4,050

500 T, 1000 T

4 x 120 SM

0.1530

318

285

41.0

4,800

5,003

500 T, 1000 T

5 x 120 RM

0.1530

51.0

6,000

6,579

500 T, 1000 T

3 x 150 SM

0.1240

359

326

40.3

4,500

4,879

500 T, 1000 T

4 x 150 SM

0.1240

359

326

45.0

6,000

6,061

500 T, 1000 T

3 x 185 SM

0.0991

406

374

44.0

5,550

6,200

500 T, 1000 T

4 x 185 SM

0.0991

406

374

49.0

7,400

7,555

500 T, 1000 T

3 x 240 SM

0.0754

473

445

52.0

7,200

8,300

800 T

4 x 240 SM

0.0754

473

445

57.0

9,600

10,143

800 T

3 x 25 RM + 16 RE

0.727/1.15

132

105

22.5

910

1,363

500 T, 1000 T

3 x 35 SM + 16 RE

0.524/1.16

159

129

23.9

1,210

1,416

500 T, 1000 T

3 x 50 SM + 25 RM

0.387/0.727

188

157

28.2

1,750

1,977

500 T, 1000 T

3 x 70 SM + 35 RM

0.268/0.524

232

199

31.9

2,450

2,720

500 T, 1000 T

3 x 95 SM + 50 RM

0.193/0.387

280

246

35.8

3,350

3,621

500 T, 1000 T

3 x 120 SM + 70 RM

0.153/0.268

318

285

40.0

4,300

4,492

500 T, 1000 T

3 x 150 SM + 70 RM

0.124/0.268

359

326

43.0

5,200

5,502

500 T, 1000 T

3 x 185 SM + 95 RM

0.0991/0.193

406

374

48.0

6,500

6,805

500 T, 1000 T

3 x 240 SM + 120 RM

0.0754/0.153

473

445

54.0

8,400

8,811

800 T

1) basic rated current acc. to VE K 23 and K 603 (HD 603)


Subject to technical changes.

Page 48

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EYY multi core


Underground cable with PVC insulation and PVC sheath, multi core
Standard: VE K 23
Usage:
Power and control cables in power stations, industrial installations
and switchgear. For fixed installation in interior premises, cable
ducts, in the open air, in water as permitted by the local building
regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

3500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

max. +160 C/5 s

Biegeradius (mind.)

12 x of cable

Core identification:

coloured (HD 308 S2)

min. 5 C
5 C to +50 C
max. +70 C

1
Fire properties:
flame retardant

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PVC)
3 Inner covering (EPDM or plastic tape)
4 Sheath (PVC black, UV resistant)

Test certificate:

Cert
.....
..

.
..

(EN 50265-2-1,
IEC 60332-1)
VE Austria

.. .. ...
Sz JZD .
. . ..
.

5
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

7 x 1.5

12.1

16.0

10 x 1.5

12.1

12 x 1.5

12.1

14 x 1.5
16 x 1.5

Current rating in the


air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

12.5

12.0

105

255

500 T, 1000 T

13.5

10.5

14.2

150

367

500 T, 1000 T

12.5

10.0

14.4

180

385

500 T, 1000 T

12.1

12.0

9.5

16.5

210

452

500 T, 1000 T

12.1

11.0

9.0

17.5

240

506

500 T, 1000 T

19 x 1.5

12.1

11.0

9.0

18.0

285

579

500 T, 1000 T

24 x 1.5

12.1

9.5

8.0

20.1

360

756

500 T, 1000 T

30 x 1.5

12.1

8.5

7.5

21.4

450

846

500 T, 1000 T

37 x 1.5

12.1

8.0

7.0

24.0

555

1,024

500 T, 1000 T

44 x 1.5

12.1

7.5

6.5

26.5

660

1,205

500 T, 1000 T

48 x 1.5

12.1

7.0

6.0

28.4

720

1,316

500 T, 1000 T

61 x 1.5

12.1

7.0

6.0

31.5

915

1,796

500 T, 1000 T

EYY0

7 x 2.5

7.41

21.5

17

14.1

175

358

500 T, 1000 T

10 x 2.5

7.41

18

14.5

17.3

250

517

500 T, 1000 T

12 x 2.5

7.41

17

13.5

17.8

300

627

500 T, 1000 T

14 x 2.5

7.41

16

13

18.6

350

702

500 T, 1000 T

16 x 2.5

7.41

15

12

20.1

400

829

500 T, 1000 T

19 x 2.5

7.41

14.5

11.5

21.1

475

945

500 T, 1000 T

24 x 2.5

7.41

12.5

10.5

23.0

600

1,027

500 T, 1000 T

Page 49

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EYY multi core


Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

30 x 2.5

7.41

11.5

37 x 2.5

7.41

44 x 2.5

7.41

48 x 2.5

7.41

61 x 2.5

7.41

7x4

4.61

10 x 4

4.61

12 x 4

4.61

14 x 4

4.61

19 x 4

4.61

24 x 4
30 x 4

Current rating in the


air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

9.5

26.1

750

1,375

500 T, 1000 T

11

28.0

925

1,649

500 T, 1000 T

10

8.5

31.0

1,100

1,950

500 T, 1000 T

33.0

1,200

2,068

500 T, 1000 T

38.0

1,525

2,630

500 T, 1000 T

27.5

22

16.5

280

566

500 T, 1000 T

23

18.5

21.1

400

737

500 T, 1000 T

21.5

17.5

21.7

480

908

500 T, 1000 T

20.5

17

23.0

560

1,100

500 T, 1000 T

18.5

15.5

27.0

760

1,300

500 T, 1000 T

4.61

16

13.5

29.0

960

1,549

500 T, 1000 T

4.61

15

12.5

35.0

1,200

2,070

500 T, 1000 T

7x6

3.08

35

28

19.0

420

704

500 T, 1000 T

7 x 10

1.83

22.1

700

1,067

500 T, 1000 T

EYY0

1) basic rated current acc. to VE K 23


Subject to technical changes.

Page 50

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

NYY
Underground cable with PVC insulation and PVC sheath
Standard: VDE 0276603
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable

Core identification:

coloured (HD 308 S2)

Fire properties:
flame retardant

(EN 50265-2-1, IEC 60332-1)

Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM)
4 Sheath (PVC black, UV-resistant)

Test certificate:

Cert
.....
..

Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal
(/km)
(A)
(A)
cross section
(mm2)

.
..

.. .. ...
Sz JZD .
. . ..
.

EZ Czech Republic,
VDE Germany,
BBJ Poland

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

NYY
2 x 1.5 RE

12.100

30

21

11.5

29

160

1000 T

3 x 1.5 RE

12.100

27

19

12.0

44

204

1000 T

4 x 1.5 RE

12.100

27

19

12.8

59

237

1000 T

5 x 1.5 RE

12.100

27

19

14.7

74

277

1000 T

2 x 2.5 RE

7.4100

39

28

12.3

49

234

1000 T

3 x 2.5 RE

7.4100

36

25

12.5

74

260

1000 T

4 x 2.5 RE

7.4100

36

25

13.8

98

307

1000 T

5 x 2.5 RE

7.4100

36

25

14.8

123

343

1000 T

2 x 4 RE

4.6100

50

37

14.1

78

312

1000 T

3 x 4 RE

4.6100

47

34

14.5

118

351

1000 T

4 x 4 RE

4.6100

47

34

15.8

157

425

1000 T

5 x 4 RE

4.6100

47

34

16.2

196

493

1000 T

2 x 6 RE

3.0800

62

47

15.1

118

389

1000 T

3 x 6 RE

3.0800

59

43

15.5

176

429

1000 T

4 x 6 RE

3.0800

59

43

17.1

235

523

1000 T

5 x 6 RE

3.0800

59

43

18.5

294

613

1000 T

2 x 10 RE

1.8300

83

64

17.0

196

546

1000 T

3 x 10 RE

1.8300

79

59

17.5

294

600

1000 T

4 x 10 RE

1.8300

79

59

19.0

392

740

1000 T

4 x 10 RM

1.8300

79

59

20.5

392

789

1000 T

5 x 10 RE

1.8300

79

59

20.6

490

884

1000 T

3 x 16 RE

1.1500

107

84

19.0

470

810

1000 T

4 x 16 RE

1.1500

102

79

22.0

627

1,039

1000 T

Page 51

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

NYY
Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal
(/km)
(A)
(A)
cross section
(mm2)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

NYY
4 x 16 RM

1.1500

102

79

23.0

627

1,054

1000 T

5 x 16 RE

1.1500

102

79

24.5

784

1,227

1000 T

4 x 25 RM

0.7270

133

106

26.7

960

1,550

1000 T

5 x 25 RM

0.7270

133

106

29.9

1,225

1,920

1000 T

4 x 35 RM

0.5240

159

129

29.6

1,372

2,007

1000 T

4 x 50 SM

0.3870

188

157

34.4

1,960

2,442

1000 T

4 x 70 SM

0.2680

232

199

43.0

2,744

3,287

500 T

4 x 95 SM

0.1930

280

246

46.6

3,724

4,543

500 T

4 x 120 SM

0.1530

318

285

46.6

4,704

5,565

500 T

4 x 150 SM

0.1240

359

326

50.4

5,880

6,713

500 T

4 x 185 SM

0.0991

406

374

57.0

7,252

8,560

500 T

4 x 240 SM

0.0754

473

445

63.2

9,408

11,140

500 T

1) basic rated current acc. to VDE 0276-603


Subject to technical changes.

Page 52

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

(N)Y2Y
Underground cable with PVC insulation and HDPE sheath
Standard: TP PRAKAB 16/03
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


4
3
2
1
Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM)
4 Sheath (HDPE black, UV-resistant)

Core identification:

Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal cross
(/km)
(A)
(A)
section
(mm2)

coloured (HD 308 S2)

Outer
diameter
(mm) ca.

Metal
weight
(mm)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

(N)Y2Y
4 x 25 RM

0.7270

133

106

26.7

960

1,475

1000 T

5 x 25 RM

0.7270

133

106

29.9

1,200

1,825

1000 T

4 x 35 RM

0.5240

159

129

29.6

1,344

1,910

1000 T

4 x 50 SM

0.3870

188

157

34.4

1,920

2,322

1000 T

4 x 70 SM

0.2680

232

199

43.0

2,688

3,125

500 T

4 x 95 SM

0.1930

280

246

46.6

3,648

4,319

500 T

4 x 120 SM

0.1530

318

285

46.6

4,608

5,290

500 T

4 x 150 SM

0.1240

359

326

50.4

5,760

6,381

500 T

4 x 185 SM

0.0991

406

374

57.0

7,104

8,137

500 T

4 x 240 SM

0.0754

473

445

63.2

9,216

10,589

500 T

1) basic rated current acc. to TP PRAKAB 16/03


Subject to technical changes.

Page 53

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

N2XY
Underground cable with XLPE insulation and PVC sheath
Standard: VDE 0276603
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Construction:
1 Copper conductor, round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (XLPE)
3 Inner covering (EPDM)
4 Sheath (PVC black, UV-resistant)

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +90 C
max. +90 C
max. +250 C/5 s

Bending radius (min.): 12 x of cable

Core identification:
Fire properties:
flame retardant

Test certificate:

Cert
.....
..

Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal cross
(/km)
(A)
(A)
section
(mm2)

Outer
diameter
(mm) ca.

.
..

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

N2XY
4 x 16 RM

1.1500

112

98

29.3

614

1,065

1000 T

4 x 25 RM

0.7270

145

133

26.7

960

1,580

1000 T

4 x 35 RM

0.5240

174

162

29.3

1,344

2,052

1000 T

4 x 50 SM

0.3870

206

197

34.4

1,920

2,461

1000 T

4 x 70 SM

0.2680

254

250

38.1

2,688

3,322

1000 T

4 x 95 SM

0.1930

305

308

43.2

3,648

4,499

500 T

4 x 120 SM

0.1530

348

359

46.6

4,608

5,508

500 T

4 x 150 SM

0.1240

392

412

48.6

5,760

6,690

500 T

4 x 185 SM

0.0991

444

475

50.4

7,104

7,334

500 T

4 x 240 SM

0.0754

517

564

55.2

9,216

9,602

500 T

1) basic rated current acc. to VDE 0276603


Subject to technical changes.

Page 54

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

N2X2Y
Underground cable with XLPE insulation and HDPE sheath
Standard: VDE 0276603
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +90 C
max. +90 C
max. +250 C/5 s

Bending radius (min.): 12 x of cable


4

Construction:
1 Copper conductor, round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (XLPE)
3 Inner covering (EPDM)
4 Sheath (HDPE black, UV-resistant)

Cert
.....
..

Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal cross
(/km)
(A)
(A)
section
(mm2)

.
..

Core identification:

coloured (HD 308 S2)

Test certificate:

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

N2X2Y
4 x 16 RM

1.1500

112

98

29.3

614

1,013

1000 T

4 x 25 RM

0.7270

145

133

26.7

960

1,502

1000 T

4 x 35 RM

0.5240

174

162

29.3

1,344

1,951

1000 T

4 x 50 SM

0.3870

206

197

34.4

1,920

2,340

1000 T

4 x 70 SM

0.2680

254

250

38.1

2,688

3,158

1000 T

4 x 95 SM

0.1930

305

308

43.2

3,648

4,278

500 T

4 x 120 SM

0.1530

348

359

46.6

4,608

2,236

500 T

4 x 150 SM

0.1240

392

412

50.4

5,760

6,359

500 T

4 x 185 SM

0.0991

444

475

50.4

6,962

6,972

500 T

4 x 240 SM

0.0754

517

564

55.2

9,032

9,127

500 T

1) basic rated current acc. to VDE 0276603


Subject to technical changes.

Page 55

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

YKY
Underground cable with PVC insulation and PVC sheath
Standard: PN-93/E-90401, PN-93/E-90400
Usage:
Power distribution cables in power stations, industrial installations and
switchgear, as well as in local mains. For fixed installation in interior
premises, cable ducts, in the open air, in water as permitted by the
local building regulations if no risk of any mechanical damage is to
be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
Fire properties:
flame retardant

4
3
2
1
Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM or plastic tape)
4 Sheath (PVC black, UV-resistant)

Number
of cores x
nominal cross
section
(mm2)

Max.
conductor
resistance
(/km)

3 x 1.5 RE

12.100

27

4 x 1.5 RE

12.100

5 x 1.5 RE

12.100

3 x 2.5 RE
4 x 2.5 RE

Test certificate:

Cert
.....
..

Current rating Current rating


in the ground1)
in the air1)
(A)
(A)

.
..

.. .. ...
Sz JZD .
. . ..
.

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
EZ Czech Republic,
BBJ Poland

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

19

11.6

44

210

1000 T

27

19

12.4

59

243

1000 T

72

19

13.3

74

278

1000 T

7.4100

36

25

12.5

74

260

1000 T

7.4100

36

25

13.4

98

304

1000 T

5 x 2.5 RE

7.4100

36

25

14.4

123

352

1000 T

3 x 4 RE

4.6100

47

34

14.3

118

358

1000 T

4 x 4 RE

4.6100

47

34

15.4

157

425

1000 T

5 x 4 RE

4.6100

47

34

16.6

196

496

1000 T

3 x 6 RE

3.0800

59

43

15.3

174

444

1000 T

4 x 6 RE

3.0800

59

43

16.6

235

535

1000 T

5 x 6 RE

3.0800

59

43

18.0

294

628

1000 T

3 x 10 RE

1.8300

79

59

15.3

294

607

1000 T

4 x 10 RE

1.8300

79

59

18.4

627

737

1000 T

5 x 10 RE

1.8300

79

59

20.0

784

883

1000 T

YKY

3 x 16 RM

1.1500

102

79

20.2

470

841

1000 T

4 x 16 RM

1.1500

102

79

22.0

627

1,027

1000 T

5 x 16 RM

1.1500

102

79

24.0

784

1,257

1000 T

4 x 25 RM

0.7270

133

106

25.4

980

1,487

1000 T

5 x 25 RM

0.7270

133

106

28.0

1,225

1,843

1000 T

4 x 35 SM

0.5370

159

129

26.4

1,372

1,646

1000 T

5 x 35 RM

0.5370

159

129

31.2

1,715

2,506

1000 T

Page 56

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

YKY
Number
of cores x
nominal cross
section
(mm2)

Max.
conductor
resistance
(/km)

Current rating Current rating


in the ground1)
in the air1)
(A)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

YKY
4 x 50 SM

0.3870

188

157

31.2

1,960

2,224

1000 T

5 x 50 RM

0.3870

188

157

36.0

2,450

3,194

1000 T

4 x 70 SM

0.2680

232

199

34.8

2,744

3,068

1000 T

5 x 70 RM

0.2680

232

199

40.8

3,430

4,354

1000 T

4 x 95 SM

0.1930

280

246

40.0

3,724

4,178

1000 T

4 x 120 SM

0.1530

318

285

43.6

4,704

5,200

500 T

4 x 150 SM

0.1240

359

326

46.8

5,880

6,306

500 T

4 x 185 SM

0.0991

406

374

53.2

7,252

7,824

500 T

4 x 240 SM

0.0754

473

445

58.7

9,408

10,271

500 T

1) basic rated current acc. to PN-93/E-90401, PN-93/E-90400


Subject to technical changes.

Page 57

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

YBY
Underground cable with PVC insulation and PVC sheath, steel-tape armoured
Standard: IEC 60502
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations when high protection against mechanical damage is required.

Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM or plastic tape)
4 Sheath (PVC black)
5 Armouring (galvanized steel tape)
6 Sheath (PVC black, UV-resistant)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

2 x 1.5 RE

12.100

31

3 x 1.5 RE

12.100

4 x 1.5 RE

12.100

5 x 1.5 RE

0.6/1 kV

Test voltage:

3500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
5 C to +50 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 15 x of cable

Number of cores x
nominal cross
section
(mm2)

Rated voltage:

Core identification:
Fire properties:
flame retardant

Current rating in the


air1)
(A)

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

19.5

11.5

30

200

500 T. 1000 T

26

19

12

45

225

500 T. 1000 T

26

19

13

60

250

500 T. 1000 T

12.100

18.5

14

14

75

285

500 T. 1000 T

2 x 2.5 RE

7.410

41

26

12.3

50

236

500 T. 1000 T

3 x 2.5 RE

7.410

35

24

12.5

75

269

500 T. 1000 T

4 x 2.5 RE

7.410

35

24

13.6

100

305

500 T. 1000 T

5 x 2.5 RE

7.410

24

19

15.5

125

369

500 T. 1000 T

2 x 4 RE

4.610

52.5

36

15

80

420

500 T. 1000 T

3 x 4 RE

4.610

44.5

33

15.5

120

459

500 T. 1000 T

4 x 4 RE

4.610

44.5

33

16

160

528

500 T. 1000 T

5 x 4 RE

4.610

31

25

18

200

624

500 T. 1000 T

2 x 6 RE

3.080

66

46.5

16

120

475

500 T. 1000 T

3 x 6 RE

3.080

56

41.5

17

180

554

500 T. 1000 T

4 x 6 RE

3.080

56

41.5

18

240

654

500 T. 1000 T

YBY

5 x 6 RE

3.080

40

31

19.5

300

760

500 T. 1000 T

2 x 10 RE

1.830

87.5

64

18

200

626

500 T. 1000 T

3 x 10 RE

1.830

75.5

57

19

300

742

500 T. 1000 T

4 x 10 RE

1.830

75.5

57

20.2

400

939

500 T. 1000 T

5 x 10 RE

1.830

53.5

42.5

21.6

500

1,086

500 T. 1000 T

4 x 10 RM

1.830

75.5

57

20.5

400

971

500 T. 1000 T

Page 58

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

YBY
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

Current rating in the


air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

5 x 10 RM

1.830

53.5

22

500

1,104

500 T. 1000 T

2 x 16 RE

1.150

112.5

86.5

19

320

845

500 T. 1000 T

3 x 16 RE

1.150

98

75.5

21.3

480

984

500 T. 1000 T

4 x 16 RE

1.150

98

75.5

23.2

640

1,240

500 T. 1000 T

YBY
42.5

5 x 16 RE

1.150

69

57

25.5

800

1,519

500 T. 1000 T

3 x 16 RM

1.150

98

75.5

22

480

1,022

500 T. 1000 T

4 x 16 RM

1.150

98

75.5

24

640

1,289

500 T. 1000 T

5 x 16 RM

1.150

69

57

26

800

1,497

500 T. 1000 T

4 x 25 RM

0.727

128

102

27.5

1,000

1,822

500 T. 1000 T

4 x 35 SM

0.524

154

125

28.7

1,400

2,036

500 T. 1000 T

3 x 50 SM + 25 RM

0.387/0.727

182

152

32.0

1,750

2,452

500 T. 1000 T

3 x 70 SM + 35 RM

0.268/0.524

225

193

36.0

2,450

3,344

500 T. 1000 T

3 x 95 SM + 50 RM

0.193/0.387

272

239

39.0

3,350

4,199

500 T. 1000 T

3 x 120 SM + 70 RM

0.153/0.268

308

276

44.0

4,300

5,247

500 T. 1000 T

3 x 150 SM + 70 RM

0.124/0.268

348

316

49.0

5,200

6,282

500 T

3 x 185 SM + 95 RM

0.0991/0.193

394

363

56.0

6,500

7,719

500 T

3 x 240 SM + 120 RM

0.0754/0.153

459

432

59.0

8,400

9,823

500 T

1) basic rated current acc. to IEC 60502


Note: This type is also available with aluminium conductor (AYBY)

Page 59

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

YRY
Underground cable with PVC insulation and PVC sheath, steel-wire armoured
Standard: IEC 60502
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations when high protection against mechanical damage is required.

Rated voltage:

0.6/1 kV

Test voltage:

3500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
5 C to +50 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 15 x of cable


8

7 6 5

Core identification:
Fire properties:
flame retardant

Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (plastic tape)
4 Sheath (PVC black)
5 Armouring (galvanized steel wires)
6 Counter helix (galvanized steel tape)
7 Outer covering (plastic tape)
8 Sheath (PVC black, UV-resistant)

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

3 x 35 SM + 16 RM

0.524/1.15

154

3 x 50 SM + 25 RM

0.387/0.727

3 x 70 SM + 35 RM

0.268/0.524

3 x 95 SM + 50 RM

Current rating in the


air1)
(A)

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

125

31.0

1,210

2,471

500 T, 1000 T

182

152

35.7

1,750

3,412

500 T, 1000 T

225

193

39.6

2,450

4,395

500 T, 1000 T

0.193/0.387

272

239

46.0

3,350

6,048

500 T, 1000 T

3 x 120 SM + 70 RM

0.153/0.268

308

276

44.0

4,300

5,247

500 T, 1000 T

3 x 150 SM + 95 RM

0.124/0.193

348

316

54.5

5,450

8,753

500 T

3 x 185 SM + 95 RM

0.0991/0.193

395

363

59.8

6,500

10,319

500 T

3 x 240 SM + 120 RM

0.0754/0.153

459

432

68.9

8,400

12,826

500 T

YRY

1) basic rated current acc. to IEC 60502


Subject to technical changes.

Page 60

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EYCY
Underground cable with PVC insulation and PVC sheath, screened
Standard: VE K 23 und K 603 (HD 603)
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations when protection against shock
hazard voltages in the event of mechanical damage or electrical screening is required.

Rated voltage:

0.6/1 kV

Test voltage:

3500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
5 C to +50 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
5
4
3
1
2
Construction:
1 Copper conductor, round solid (RE) or round stranded (RM)
2 Core insulation (PVC)
3 Inner covering (EPDM) in case of multicore constructions
4 Concentric screen (bare copper wires) and counter helix (copper tape)
5 Sheath (PVC black, UV-resistant)

Fire properties:
flame retardant

Test certificate:

Cert
.....
..

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
VE Austria

.. .. ...
.
.
.. . Sz JZD .
. . .

Number of cores x Max. conductor Current rating


nominal cross
resistance
in the ground1)
section/cross
(/km)
(A)
section of screen
(mm2)

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

EYCY
2 x 1.5 RE/1.5

12.100

32

20

10.8

58

181

500 T, 1000 T

3 x 1.5 RE/1.5

12.100

27

19.5

11.2

73

202

500 T, 1000 T

4 x 1.5 RE/1.5

12.100

27

19.5

11.7

88

230

500 T, 1000 T

5 x 1.5 RE/1.5

12.100

19

14.5

12.8

103

252

500 T, 1000 T

2 x 1.5 RE/16

12.100

32

20

12.1

220

313

500 T, 1000 T

3 x 1.5 RE/16

12.100

27

19.5

12.5

235

327

500 T, 1000 T

4 x 1.5 RE/16

12.100

27

19.5

14.0

250

362

500 T, 1000 T

5 x 1.5 RE/16

12.100

19

14.5

14.1

270

375

500 T, 1000 T

2 x 2.5 RE/2.5

7.410

42

27

11.9

88

230

500 T, 1000 T

3 x 2.5 RE/2.5

7.410

36

25

12.1

113

249

500 T, 1000 T

4 x 2.5 RE/2.5

7.410

36

25

13.0

138

283

500 T, 1000 T

5 x 2.5 RE/2.5

7.410

25

19.5

14.4

163

339

500 T, 1000 T

3 x 2.5 RE/16

7.410

36

25

12.5

265

377

500 T, 1000 T

4 x 2.5 RE/16

7.410

36

25

13.4

290

415

500 T, 1000 T

5 x 2.5 RE/16

7.410

25

19.5

15.4

315

463

500 T, 1000 T

2 x 4 RE/4

4.610

54

37

13.9

133

336

500 T, 1000 T

3 x 4 RE/4

4.610

46

34

14.7

168

359

500 T, 1000 T

4 x 4 RE/4

4.610

46

34

15.7

208

429

500 T, 1000 T

Page 61

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EYCY
Number
of cores x
nominal cross
section
(mm2)

Max. conductor Current rating Current rating


resistance
in the ground1)
in the air1)
(/km)
(A)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

EYCY
2 x 4 RE/16

4.610

54

37

14.7

270

445

500 T, 1000 T

4 x 4 RE/16

4.610

46

34

16.0

350

530

500 T, 1000 T

5 x 4 RE/16

4.610

32

25.5

17.9

390

601

500 T, 1000 T

2 x 6 RE/6

3.080

68

48

15.5

195

390

500 T, 1000 T

3 x 6 RE/6

3.080

58

43

16.2

250

460

500 T, 1000 T

4 x 6 RE/6

3.080

58

43

17.5

309

547

500 T, 1000 T

2 x 6 RE/16

3.080

68

48

16.0

310

477

500 T, 1000 T

4 x 6 RE/16

3.080

58

43

17.6

430

635

500 T, 1000 T

5 x 6 RE/16

3.080

41

32

19.3

490

726

500 T, 1000 T

2 x 10 RE/16

1.830

90

66

17.5

390

600

500 T, 1000 T

4 x 10 RE/16

1.830

78

59

19.6

590

850

500 T, 1000 T

4 x 10 RM/16

1.830

78

59

20.6

590

873

500 T, 1000 T

5 x 10 RM/16

1.830

55

44

23.7

690

1,012

500 T, 1000 T

2 x 16 RE/16

1.150

116

89

19.5

510

803

500 T, 1000 T

3 x 16 RE/16

1.150

101

78

21.0

670

937

500 T, 1000 T

4 x 16 RE/16

1.150

101

78

22.2

830

1,136

500 T, 1000 T

4 x 16 RM/16

1.150

101

78

23.9

830

1,181

500 T, 1000 T

5 x 16 RM/16

1.150

71

59

26

990

1,380

500 T, 1000 T

3 x 25 RM/16

0.727

132

105

25.0

940

1,419

500 T, 1000 T

4 x 25 RM/16

0.727

132

105

28.1

1,190

1,637

500 T, 1000 T

7 x 1.5/2.5

12.100

16

12.5

14.4

143

335

500 T, 1000 T

7 x 1.5/16

12.100

16

12.5

17.8

295

457

500 T, 1000 T

10 x 1.5/2.5

12.100

13.5

10.5

16.9

188

468

500 T, 1000 T

10 x 1.5/16

12.100

13.5

10.5

18.1

340

588

500 T, 1000 T

12 x 1.5/2.5

12.100

12.5

10

16.2

218

479

500 T, 1000 T

12 x 1.5/16

12.100

12.5

10

17.6

370

613

500 T, 1000 T

14 x 1.5/16

12.100

12

9.5

19.2

400

676

500 T, 1000 T

16 x 1.5/4

12.100

11

20

288

585

500 T, 1000 T

16 x 1.5/16

12.100

11

21

430

720

500 T, 1000 T

19 x 1.5/4

12.100

11

20.1

333

701

500 T, 1000 T

19 x 1.5/16

12.100

11

20.9

475

808

500 T, 1000 T

24 x 1.5/6

12.100

9.5

24

435

931

500 T, 1000 T

24 x 1.5/16

12.100

9.5

24.2

550

1,041

500 T, 1000 T

30 x 1.5/16

12.100

8.5

7.5

25.5

640

1,119

500 T, 1000 T

37 x 1.5/16

12.100

27.8

745

1,300

500 T, 1000 T

44 x 1.5/16

12.100

7.5

6.5

33

850

1,500

500 T, 1000 T

48 x 1.5/16

12.100

31

910

1,601

500 T, 1000 T

61 x 1.5/16

12.100

33.4

1,105

1,945

500 T, 1000 T

Page 62

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EYCY
Number
of cores x
nominal cross
section
(mm2)

Max. conductor Current rating Current rating


resistance
in the ground1)
in the air1)
(/km)
(A)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

EYCY
7 x 2.5/2.5

7.410

21.5

17

15.4

208

448

500 T, 1000 T

7 x 2.5/16

7.410

21.5

17

16.3

365

572

500 T, 1000 T

10 x 2.5/16

7.410

18

14.5

19.9

440

742

500 T, 1000 T

12 x 2.5/16

7.410

17

13.5

20.4

490

847

500 T, 1000 T

14 x 2.5/16

7.410

16

13

21.4

540

922

500 T, 1000 T

16 x 2.5/6

7.410

15

12

22

470

830

500 T, 1000 T

16 x 2.5/16

7.410

15

12

23

590

1,100

500 T, 1000 T

19 x 2.5/16

7.410

14.5

11.5

24.2

665

1,188

500 T, 1000 T

24 x 2.5/16

7.410

12.5

10.5

27.4

790

1,308

500 T, 1000 T

30 x 2.5/16

7.410

11.5

9.5

28.7

940

1,670

500 T, 1000 T

37 x 2.5/16

7.410

11

31.2

1,115

1,968

500 T, 1000 T

48 x 2.5/16

7.410

34.4

1,390

2,431

500 T, 1000 T

1) basic rated current acc. to VE K 603


Subject to technical changes.

Page 63

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

NYCY
Underground cable with PVC insulation and PVC sheath, screened
Standard: VDE 0276-603
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in
interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations when protection against shock
hazard voltages in the event of mechanical damage or electrical
screening is required.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 15 C
30 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
5
4
3
1
2
Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PVC)
3 Inner covering (EPDM and PVC)
4 Concentric screen (bare copper wires) and counter helix (copper tape)
5 Sheath (PVC black, UV-resistant)
Number of cores x Max. conductor Current rating
nominal cross
resistance
in the ground1)
section/cross
(/km)
(A)
section of screen
(mm2)

Current rating
in the air1)
(A)

Fire properties:
flame retardant

Test certificate:

Cert
.....
..

.
..

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

NYCY
2 x 1.5 RE/1.5

12.1

32

27

13

54

210

1000 T

3 x 1.5 RE/1.5

12.1

27

19

14

69

220

1000 T

4 x 1.5 RE/1.5

12.1

27

19

14

84

260

1000 T

5 x 1.5 RE/1.5

12.1

27

19

15

98

324

1000 T

7 x 1.5 RE/2.5

12.1

15

12

16

137

350

1000 T

8 x 1.5 RE/2.5

12.1

15

12

17

152

460

1000 T

10 x 1.5 RE/2.5

12.1

13

10

19

49

420

1000 T

12 x 1.5 RE/2.5

12.1

11

20

49

480

1000 T

14 x 1.5 RE/2.5

12.1

11

21

49

530

1000 T

16 x 1.5 RE/4

12.1

10

22

64

700

1000 T

19 x 1.5 RE/4

12.1

10

23

64

670

1000 T

24 x 1.5 RE/6

12.1

26

98

870

1000 T

30 x 1.5 RE/6

12.1

27

113

1,250

1000 T

40 x 1.5 RE/10

12.1

30

167

1,560

500 T

2 x 2.5 RE/2.5

7.41

43

31

14

84

260

1000 T

3 x 2.5 RE/2.5

7.41

36

26

15

108

290

1000 T

4 x 2.5 RE/2.5

7.41

36

26

15

133

340

1000 T

5 x 2.5 RE/2.5

7.41

36

26

16

157

390

1000 T

7 x 2.5 RE/2.5

7.41

20

16

17

206

450

1000 T

8 x 2.5 RE/2.5

7.41

20

16

18

231

570

1000 T

10 x 2.5 RE/4

7.41

17

13

21

74

610

1000 T

Page 64

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

NYCY
Number of cores x Max. conductor Current rating
nominal cross
resistance
in the ground1)
section/cross
(/km)
(A)
section of screen
(mm2)

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

NYCY
12 x 2.5 RE/4

7.41

15

12

22

74

670

1000 T

14 x 2.5 RE/6

7.41

15

12

23

93

750

1000 T

16 x 2.5 RE/6

7.41

13

11

24

93

900

1000 T

19 x 2.5 RE/6

7.41

13

11

25

93

950

1000 T

24 x 2.5 RE/10

7.41

12

10

28

157

1,420

1000 T

30 x 2.5 RE/10

7.41

10

30

182

1,600

1000 T

40 x 2.5 RE/10

7.41

10

33

206

2,000

500 T

2 x 4 RE/4

4.61

56

41

16

128

350

1000 T

3 x 4 RE/4

4.61

47

34

16

167

400

1000 T

4 x 4 RE/4

4.61

47

34

17

206

470

1000 T

7 x 4 RE/4

4.61

29

20

20

324

600

1000 T

3 x 6 RE/6

3.08

59

44

18

245

500

1000 T

4 x 6 RE/6

3.08

59

44

19

304

590

1000 T

5
1) basic rated current acc. to VDE 0276-630
Subject to technical changes.

Page 65

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

NYCWY
Underground cable with PVC insulation and PVC sheath, screened
Standard: VDE 0276-603
Usage:
Power distribution cables in power stations, industrial installations and
switchgear, as well as in local mains. For fixed installation in interior
premises, cable ducts, in the open air, in water as permitted by the
local building regulations when protection against shock hazard voltages in the event of mechanical damage is required. The concentric
Ceander conductor can be used as PE or PEN conductor and must
not be cut when assembling branch tees.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 15 C
30 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
5
4
3
2 1
Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM)
4 Concentric screen (bare copper wires applied with changing
direction of lay) and counter helix (copper tape)
5 Sheath (PVC black, UV-resistant)
Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

2 x 10 RE/10

1.8300

95

3 x 10 RE/10

1.8300

4 x 10 RE/10

1.8300

2 x 16 RE/16
3 x 16 RE/16

Fire properties:
flame retardant

Test certificate:

Cert
.....
..

Current rating in the


air1)
(A)

.
..

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

72

19.0

304

643

1000 T

79

60

22.0

402

854

1000 T

79

60

21.5

500

913

1000 T

1.1500

122

95

22.0

485

889

1000 T

1.1500

102

80

22.0

642

1,020

1000 T

4 x 16 RE/16

1.1500

102

80

25.5

799

1,309

1000 T

3 x 25 RM/16

0.7270

133

108

26.0

907

1,438

1000 T

3 x 25 RM/25

0.7270

133

108

26.5

995

1,524

1000 T

NYCWY

4 x 25 RM/16

0.7270

133

108

28.0

1,152

1,709

1000 T

3 x 35 SM/16

0.5240

160

132

28.0

1,201

1,583

1000 T

3 x 35 SM/35

0.5240

160

132

29.0

1,387

1,947

1000 T

4 x 35 SM/16

0.5240

160

132

31.5

1,544

1,990

1000 T

3 x 50 SM/25

0.3870

190

160

32.0

1,730

2,112

1000 T

3 x 50 SM/50

0.3870

190

160

32.5

1,975

2,326

1000 T

4 x 50 SM/25

0.3870

190

160

36.0

2,220

2,688

1000 T

3 x 70 SM/35

0.2680

234

202

36.0

2,416

2,931

1000 T

3 x 70 SM/70

0.2680

234

202

36.5

2,759

3,255

1000 T

4 x 70 SM/35

0.2680

234

202

40.5

3,102

3,650

1000 T

3 x 95 SM/50

0.1930

280

249

40.5

3,303

3,867

1000 T

3 x 95 SM/95

0.1930

280

249

41.5

3,744

4,317

1000 T

4 x 95 SM/50

0.1930

280

249

46.0

4,234

5,001

500 T

Page 66

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

NYCWY
Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

3 x 120 SM/70

0.1530

319

3 x 120 SM/120

0.1530

4 x 120 SM/70
3 x 150 SM/70

Current rating in the


air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

289

44.0

4,234

4,778

500 T

319

289

44.0

4,724

5,255

500 T

0.1530

319

289

50.0

5,410

6,736

500 T

0.1240

357

329

48.5

5,116

5,863

500 T

3 x 150 SM/150

0.1240

357

329

50.0

5,900

6,608

500 T

4 x 150 SM/70

0.1240

357

329

56.0

6,586

7,985

500 T

3 x 185 SM/95

0.0991

402

377

52.5

6,390

8,120

500 T

4 x 185 SM/95

0.0991

402

377

59.5

8,203

9,305

500 T

3 x 240 SM/120

0.0754

463

443

59.0

8,252

9,312

500 T

4 x 240 SM/120

0.0754

463

443

66.0

10,604

12,105

500 T

1 x 300 RM/35

0.0601

518

504

34.3

3,303

3,759

1000 T

NYCWY

1) basic rated current acc. to VDE 0276-630


Subject to technical changes.

Page 67

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

1AYKY
Underground cable with PVC insulation and PVC sheath
Standard: TP PRAKAB 01/03
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
50 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 15 x of cable


4
3
2
1
Construction:
1 Aluminium conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM or plastic tape)
4 Sheath (PVC black, UV-resistant)

Current rating in the


air1)
(A)

coloured (HD 308 S2)

Fire properties:
flame retardant

(EN 50265-2-1, IEC 60332-1)

Test certificate:

Cert
.....
..

Core identification:

.
..

.. .. ...
Sz JZD .
. . ..
.

EZ Czech Republic,
EVP Slovak Republic

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

4 x 25 RE

1.238

103

78

22.4

300

750

1000 T

5 x 25 RE

1.238

103

78

24.4

375

880

1000 T

3 x 35 + 25 RE/RE

0.885/1.238

125

96

24.7

390

909

1000 T

4 x 35 RE

0.885

125

96

24.7

420

939

1000 T

5 x 35 RE

0.885

125

96

27.1

525

1,108

1000 T

3 x 50 + 35 RE/RE

0.641/0.885

147

117

28.9

505

1,219

1000 T

1AYKY

4 x 50 RE

0.641

147

117

28.9

600

1,275

1000 T

4 x 50 SM

0.641

147

117

30.4

600

1,089

1000 T

4 x 70 RE

0.443

183

150

32.2

840

1,618

1000 T

3 x 70 + 50 RE/RE

0.443/0.641

183

150

32.2

780

1,559

1000 T

3 x 70 + 50 SM/RM

0.443/0.641

183

150

33.6

780

1,314

1000 T

4 x 70 RM

0.443

183

150

35.4

840

1,814

1000 T

4 x 70 SM

0.443

183

150

33.6

840

1,345

1000 T

3 x 95 + 70 SM/RM

0.326/0.443

216

182

39.3

1,065

1,743

1000 T

4 x 95 SM

0.326

216

182

39.3

1,140

1,836

1000 T

3 x 120 + 70 SM/RE

0.258/0.443

245

212

40.6

1,290

2,000

1000 T

3 x 120 + 70 SM/RM

0.258/0.443

245

212

43.0

1,290

2,057

1000 T

4 x 120 SM

0.258

245

212

43.0

1,440

2,225

1000 T

3 x 150 + 70 SM/RE

0.206/0.443

278

245

45.6

1,560

2,415

500 T

3 x 150 + 70 SM/RM

0.206/0.443

278

245

46.8

1,560

2,457

500 T

4 x 150 SM

0.206

278

245

46.8

1,800

2,734

500 T

3 x 185 + 95 SM/RE

0.167/0.326

313

280

48.4

1,950

2,950

500 T

3 x 185 + 95 SM/RM

0.167/0.326

313

280

49.8

1,950

3,009

500 T

3 x 185 + 95 SM/SM

0.167/0.326

313

280

48.4

1,950

2,993

500 T

Page 68

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

1AYKY
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

Current rating in the


air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1AYKY
4 x 185 SM

0.167

313

280

49.8

2,220

3,364

500 T

3 x 240 + 120 SM/RE

0.129/0.258

359

330

54.8

2,520

3,728

500 T

3 x 240 + 120 SM/RM

0.129/0.258

359

330

56.4

2,520

3,804

500 T

4 x 240 SM

0.129

359

330

56.4

2,880

4,217

500 T

1) basic rated current acc. to TP PRAKAB 01/03


Subject to technical changes.

Page 69

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EAYY
Underground cable with PVC insulation and PVC sheath
Standard: VE K 23 and K 603 (HD 603)
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

1 x 25 RM

1.200

106

1 x 35 RM

0.868

1 x 50 RM

0.641

1 x 70 RM
1 x 95 RM

3500 Veff

Core identification:
Fire properties:
flame retardant

Current rating in the


air1)
(A)

Test certificate:

Cert
.....
..

Current rating in the


ground1)
(A)

Test voltage:

min. 5 C
5 C to +50 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 15 x of cable


(single core)
12 x of cable
(multi core)

Construction:
1 Aluminium conductor, round solid (RE), sector-shaped solid (SE),
round stranded (RM) resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM or plastic tape) in case of multicore
constructions
4 Sheath (PVC black, UV-resistant)

Max. conductor
resistance
(/km)

0.6/1 kV

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

Number of cores x
nominal cross
section
(mm2)

Rated voltage:

.
..

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
VE Austria

.. .. ...
Sz JZD .
. . ..
.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

87

11.3

74

174

500 T, 1000 T

127

107

12.4

103

231

500 T, 1000 T

151

131

13.8

147

296

500 T, 1000 T

0.443

185

166

15.8

206

375

500 T, 1000 T

0.320

222

205

17.6

279

485

500 T, 1000 T

1 x 120 RM

0.253

253

239

19.1

353

580

500 T, 1000 T

1 x 150 RM

0.206

284

273

22.5

441

737

500 T, 1000 T

1 x 185 RM

0.164

322

317

25.1

544

895

500 T, 1000 T

1 x 240 RM

0.125

375

378

26.5

706

1,058

500 T, 1000 T

1 x 300 RM

0.100

423

434

30.7

882

1,344

500 T, 1000 T

1 x 25 RM

1.200

106

87

11.3

74

174

500 T, 1000 T

1 x 35 RM

0.868

127

107

12.4

103

231

500 T, 1000 T

1 x 50 RM

0.641

151

131

13.8

147

296

500 T, 1000 T

1 x 70 RM

0.443

185

166

15.8

206

375

500 T, 1000 T

1 x 95 RM

0.320

222

205

17.6

279

485

500 T, 1000 T

1 x 120 RM

0.253

253

239

19.1

353

580

500 T, 1000 T

1 x 150 RM

0.206

284

273

22.5

441

737

500 T, 1000 T

1 x 185 RM

0.164

322

317

25.1

544

895

500 T, 1000 T

EAYY0

EAYYJ

Page 70

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EAYY
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

1 x 240 RM

0.125

375

1 x 300 RM

0.100

423

Current rating in the


air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

378

26.5

706

1,058

500 T, 1000 T

434

30.7

882

1,344

500 T, 1000 T

24.0

294

843

500 T, 1000 T

EAYYJ

EAYYJ/EAYYJN
4 x 25 RM

1.200

102

81

4 x 25 RE

1.200

102

81

24.0

294

769

500 T, 1000 T

4 x 35 SM

0.868

122

99

27.0

412

956

500 T, 1000 T

4 x 35 RE

0.868

122

99

26.8

412

1,058

500 T, 1000 T

4 x 50 SM

0.641

144

119

28.0

588

1,021

500 T, 1000 T

4 x 50 SE

0.641

144

119

26.9

588

970

500 T, 1000 T

4 x 70 SM

0.443

179

152

32.0

823

1,341

500 T, 1000 T

4 x 70 SE

0.443

179

152

30.9

823

1,302

500 T, 1000 T

4 x 95 SM

0.320

215

186

36.5

1,117

1,805

500 T, 1000 T

4 x 95 SE

0.320

215

186

35.8

1,117

1,680

500 T, 1000 T

3 x 120 SM

0.253

245

216

36.0

1,058

1,824

500 T, 1000 T

4 x 120 SM

0.253

245

216

41.8

1,411

2,225

500 T, 1000 T

4 x 120 SE

0.253

245

216

37.8

1,411

1,997

500 T, 1000 T

3 x 150 SM

0.206

275

246

40.3

1,323

2,035

500 T, 1000 T

4 x 150 SM

0.206

275

246

45.0

1,764

2,605

500 T, 1000 T

4 x 150 SE

0.206

275

246

40.8

1,764

2,490

500 T, 1000 T

3 x 185 SM

0.164

313

285

44.0

1,632

2,760

500 T, 1000 T

4 x 185 SM

0.164

313

285

48.0

2,176

3,242

500 T, 1000 T

3 x 240 SM

0.125

364

338

52.0

2,117

3,277

500 T

4 x 240 SM

0.125

364

338

56.0

2,822

4,217

500 T

3 x 150 SM + 70 RM

0.206/0.443

275

246

43.0

1,529

2,333

500 T

3 x 185 + 95 SM

0.164/0.320

313

285

50.0

1,911

3,036

500 T

3 x 240 + 120 SM

0.125/0.253

364

338

53.0

2,470

3,751

500 T

1) basic rated current acc. to VE K 23 and K 603 (HD 603)


Subject to technical changes.

Page 71

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EXAYY
Underground cable with PVC insulation and PVC sheath
Standard: adapted to VE K 23 and K 603 (HD 603)
Usage:
Power distribution cables in power stations, industrial installations and
switchgear, as well as in local mains. For fixed installation in interior
premises, cable ducts, in the open air, in water as permitted by the
local building regulations if no risk of any mechanical damage is to
be expected.

Rated voltage:

0.6/1 kV

Test voltage:

3500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
5 C to +50 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
5

Construction:
1 Aluminium conductor, round solid (RE), round stranded (RM) resp.
sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Signalling core (single copper wire, max. 7.41 Ohm/km, with red
PVC insulation) as central element
4 Inner covering (EPDM or plastic tape)
5 Sheath (PVC black, UV-resistant)

Number
of cores x
nominal cross
section
(mm2)

Max.
conductor
resistance
(/km)

Current
rating in the
ground1)
(A)

Current
rating
in the air1)
(A)

4 x 16 RE + 2.5

1.910

78

60

4 x 16 RM + 2.5

1.910

78

4 x 25 RM + 2.5

1.200

102

4 x 35 SM + 2.5

0.868

122

4 x 50 SM + 2.5

0.641

144

4 x 70 SM + 2.5

0.443

179

152

4 x 95 SM + 2.5

0.320

215

186

4 x 120 SM + 2.5

0.253

245

4 x 150 SM + 2.5

0.206

4 x 185 SM + 2.5

0.164

4 x 240 SM + 2.5

0.125

Outer
diameter
(mm) ca.

Fire properties:
flame retardant

coloured (HD 308 S2))

(EN 50265-2-1,
IEC 60332-1)

Al weight
(kg/km)

Cu weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

21.0

188

25

588

500 T. 1000 T

60

21.5

188

25

671

500 T. 1000 T

106

24.0

294

25

873

500 T. 1000 T

99

25.0

412

25

809

500 T. 1000 T

119

28.0

588

25

1,049

500 T. 1000 T

31.4

823

25

1,355

500 T. 1000 T

36.5

1,117

25

1,832

500 T. 1000 T

216

41.0

1,411

25

2,319

500 T. 1000 T

275

246

44.0

1,764

25

2,634

500 T. 1000 T

313

285

51.0

2,164

25

3,256

500 T

364

338

55.7

2,823

25

4,167

500 T

EXAYY

1) basic rated current acc. to VE K 23 and K 603 (HD 603)


Subject to technical changes.

Page 72

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EAY2Y
Underground cable with PVC insulation and HDPE sheath
Standard: VE K 23 and K 603 (HD 603)
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations under severe mechanical stressing during installation and operation.

Rated voltage:

0.6/1 kV

Test voltage:

3500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
5 C to +50 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable

Core identification:

coloured (HD 308 S2)

Test certificate:

VE Austria

1
Cert
.....
..

Construction:
1 Aluminium conductor, round solid (RE), sector-shaped solid (SE),
round stranded (RM) resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM or plastic tape) in case of multicore
constructions
4 Sheath (HDPE black, UV-resistant), min. shore D 55

Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal cross
(/km)
(A)
(A)
section
(mm2)

.
..

.. .. ...
Sz JZD .
. . ..
.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

294

700

500 T, 1000 T

EAY2Y
4 x 25 RM

1.200

102

81

26.0

4 x 25 RE

1.200

102

81

25.0

294

689

500 T, 1000 T

4 x 35 SM

0.868

122

99

24.5

412

729

500 T, 1000 T

4 x 50 SM

0.641

144

119

27.0

588

929

500 T, 1000 T

4 x 50 SE

0.641

144

119

26.5

588

900

500 T, 1000 T

4 x 70 SM

0.443

179

152

31.2

823

1,235

500 T, 1000 T

4 x 70 SE

0.443

179

152

31.0

823

1,242

500 T, 1000 T

4 x 95 SM

0.320

215

186

35.0

1,117

1,632

500 T, 1000 T

4 x 95 SE

0.320

215

186

33.5

1,117

1,573

500 T, 1000 T

4 x 120 SM

0.253

245

216

44.5

1,411

2,068

500 T, 1000 T

4 x 120 SE

0.253

245

216

41.0

1,411

1,895

500 T, 1000 T

4 x 150 SM

0.206

275

246

43.3

1,764

2,457

500 T, 1000 T

4 x 150 SE

0.206

275

246

40.0

1,764

2,320

500 T, 1000 T

4 x 185 SM

0.164

313

285

53.0

2,176

3 102

500 T

4 x 240 SM

0.125

364

338

54.5

2,822

3,985

500 T

3 x 240 + 120 SM

0.125/0.253

364

338

52.0

2,470

3,510

500 T

1) basic rated current acc. to VE K 23 and K 603 (HD 603)


Subject to technical changes.

Page 73

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

EXAY2Y
Underground cable with PVC insulation and HDPE sheath
Standard: adapted to VE K 23 and K 603 (HD 603)
Usage:
Power distribution cables in power stations, industrial installations and
switchgear, as well as in local mains. For fixed installation in interior
premises, cable ducts, in the open air, in water as permitted by the
local building regulations under severe mechanical stressing during
installation and operation.

Rated voltage:

0.6/1 kV

Test voltage:

3500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
5 C to +50 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
5

coloured (HD 308 S2)

Construction:
1 Aluminium conductor, round solid (RE), round stranded (RM) resp.
sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Signalling core (single copper wire, max. 7.41 /km, with red PVC
insulation) as central element
4 Inner covering (EPDM or plastic tape)
5 Sheath (HDPE black, UV-resistant)

Number
of cores x
nominal cross
section
(mm2)

Max.
conductor
resistance
(/km)

Current
rating in the
ground1)
(A)

Current
rating
in the air1)
(A)

4 x 16 RE + 2.5

1.910

78

60

4 x 16 RM + 2.5

1.910

78

4 x 25 RM + 2.5

1.200

102

4 x 35 SM + 2.5

0.868

122

4 x 50 SM + 2.5

0.641

144

4 x 70 SM + 2.5

0.443

179

152

4 x 95 SM + 2.5

0.320

215

186

4 x 120 SM + 2.5

0.253

245

4 x 150 SM + 2.5

0.206

4 x 185 SM + 2.5

0.164

4 x 240 SM + 2.5

0.125

Outer
diameter
(mm) ca.

Al weight
(kg/km)

Cu weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

21.0

188

25

548

500 T. 1000 T

60

21.4

188

25

589

500 T. 1000 T

106

23.0

294

25

897

500 T. 1000 T

99

24.5

412

25

737

500 T. 1000 T

119

28.0

588

25

1,049

500 T. 1000 T

31.0

823

25

1,263

500 T. 1000 T

36.0

1,117

25

1,690

500 T. 1000 T

216

40.0

1,411

25

2,114

500 T. 1000 T

275

246

43.5

1,764

25

2,462

500 T. 1000 T

313

285

50.0

2,164

25

3,116

1000 T

364

338

55.0

2,823

25

3,951

500 T

EXAY2Y

1) basic rated current acc. to VE K 23 and K 603 (HD 603)


Subject to technical changes.

Page 74

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

NAYY
Underground cable with PVC insulation and PVC sheath
Standard: VDE 0276-603
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
4
3
2
1
Construction:
1 Aluminium conductor, round solid (RE), sector-shaped solid (SE),
round stranded (RM) resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM)
4 Sheath (PVC black, UV-resistant)

Fire properties:
flame retardant

Test certificate:

Cert
.....
..

.
..

.. .. ...
Sz JZD .
. . ..
.

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
EZ Czech Republic,
VDE Germany

5
Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal
(/km)
(A)
(A)
cross section
(mm2)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

NAYY
4 x 25 RE

1.200

102

82

25.5

290

988

1000 T

4 x 25 RM

1.200

102

82

26.7

290

1,032

1000 T

4 x 35 RE

0.868

123

100

27.8

406

1,129

1000 T

4 x 35 RM

0.868

123

100

29.3

406

1,180

1000 T

4 x 50 RE

0.641

144

119

31.9

580

1,295

1000 T

4 x 50 RM

0.641

144

119

34.4

580

1,353

1000 T

4 x 70 SE

0.443

179

152

36.1

812

1,740

1000 T

4 x 70 SM

0.443

179

152

38.0

812

1,818

1000 T

4 x 95 SE

0.320

215

186

40.3

1,102

2,331

1000 T

4 x 120 SE

0.253

245

216

43.5

1,392

2,660

1000 T

4 x 120 SM

0.253

245

216

46.6

1,392

2,779

1000 T

4 x 150 SE

0.206

275

246

47.7

1,740

3,112

500 T

4 x 150 SM

0.206

275

246

50.4

1,740

3,251

500 T

4 x 185 SE

0.164

313

285

52.7

2,146

4,167

500 T

4 x 185 SM

0.164

313

285

57.0

2,146

4,353

500 T

4 x 240 SE

0.125

364

338

58.2

2,784

5,150

500 T

4 x 240 SM

0.125

364

338

63.2

2,784

5,380

500 T

1) basic rated current acc. to VDE 0276-603


Subject to technical changes.

Page 75

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

(N)AY2Y
Underground cable with PVC insulation and HDPE sheath
Standard: TP PRAKAB 12/03
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations under severe mechanical stressing during installation and operation.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


4
3
2
1
Construction:
1 Aluminium conductor, round solid (RE), sector-shaped solid (SE),
round stranded (RM) resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM)
4 Sheath (HDPE black, UV-resistant)

Number
of cores x
nominal cross
section
(mm2)

Max.
conductor
resistance
(/km)

Current rating Current rating


in the ground1)
in the air1)
(A)
(A)

4 x 25 RE

1.200

102

4 x 25 RM

1.200

4 x 35 RE

0.868

Cert
.....
..

Outer
diameter
(mm) ca.

.
..

Core identification:

coloured (HD 308 S2)

Test certificate:

EZ Czech Republic

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

924

1000 T

(N)AY2Y
82

25.5

290

102

82

26.7

290

987

1000 T

123

100

27.8

406

1,120

1000 T

4 x 35 RM

0.868

123

100

29.3

406

1,200

1000 T

4 x 50 SE

0.641

144

119

31.9

580

1,228

1000 T

4 x 50 SM

0.641

144

119

34.4

580

1,334

1000 T

4 x 70 SE

0.443

179

152

36.1

812

1,590

1000 T

4 x 70 SM

0.443

179

152

38.0

812

1,700

1000 T

4 x 95 SE

0.320

215

186

40.3

1,102

2,084

1000 T

4 x 95 SM

0.320

215

186

43.0

1,102

2,229

1000 T

4 x 120 SE

0.253

245

216

43.5

1,392

2,533

1000 T

4 x 120 SM

0.253

245

216

46.6

1,392

2,697

1000 T

4 x 150 SE

0.206

275

246

47.7

1,740

3,010

500 T

4 x 150 SM

0.206

275

246

50.4

1,740

3,186

500 T

4 x 185 SE

0.164

313

285

52.7

2,146

3,574

500 T

4 x 185 SM

0.164

313

285

57.0

2,146

3,989

500 T

4 x 240 SE

0.125

364

338

58.2

2,784

4,694

500 T

4 x 240 SM

0.125

364

338

63.2

2,784

4,972

500 T

1) basic rated current acc. to TP PRAKAB 12/03


Subject to technical changes.

Page 76

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

NA2XY
Underground cable with XLPE insulation and PVC sheath
Standard: VDE 0276-603
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +90 C
max. +90 C
max. +250 C/5 s

Bending radius (min.): 12 x of cable


4
3
2
1
Construction:
1 Aluminium conductor, round solid (RE), sector-shaped solid (SE),
round stranded (RM) resp. sector-shaped stranded (SM)
2 Core insulation (XLPE)
3 Inner covering (EPDM)
4 Sheath (PVC black, UV-resistant)

Cert
.....
..

.
..

Core identification:

coloured (HD 308 S2)

Fire properties:
flame retardant

(EN 50265-2-1, IEC 60332-1)

Test certificate:

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

5
Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal cross
(/km)
(A)
(A)
section
(mm2)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

92

25.5

290

882

1000 T

NA2XY
4 x 25 RE

1.200

112

4 x 25 RM

1.200

112

92

26.7

290

893

1000 T

4 x 35 RE

0.868

135

112

27.8

406

948

1000 T

4 x 35 RM

0.868

135

112

29.3

406

1,009

1000 T

4 x 50 SE

0.641

158

133

31.9

580

989

1000 T

4 x 50 SM

0.641

158

133

34.4

580

1,094

1000 T

4 x 70 SE

0.443

196

169

36.1

812

1,375

1000 T

4 x 70 SM

0.443

196

169

38.0

812

1,440

1000 T

4 x 95 SE

0.320

234

205

40.3

1,102

1,746

1000 T

4 x 95 SM

0.320

234

205

43.0

1,102

1,806

1000 T

4 x 120 SE

0.253

268

239

43.5

1,392

2,080

1000 T

4 x 120 SM

0.253

268

239

46.6

1,392

2,178

1000 T

4 x 150 SE

0.206

300

271

47.7

1,740

2,705

500 T

4 x 150 SM

0.206

300

271

50.4

1,740

2,741

500 T

4 x 185 SE

0.164

342

314

52.7

2,146

3,288

500 T

4 x 185 SM

0.164

342

314

57.0

2,146

3,461

500 T

4 x 240 SE

0.125

398

372

58.2

2,784

4,088

500 T

4 x 240 SM

0.125

398

372

63.2

2,784

4,281

500 T

1) basic rated current acc. to VDE 0276-603


Subject to technical changes.

Page 77

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

NA2X2Y
Underground cable with XLPE insulation and HDPE sheath
Standard: VDE 0276-603
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations under severe mechanical stressing during installation and operation.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +90 C
max. +90C
max. +250 C/5 s

Bending radius (min.): 12 x of cable


4
3
2
1
Construction:
1 Aluminium conductor, round solid (RE), sector-shaped solid (SE),
round stranded (RM) resp. sector-shaped stranded (SM)
2 Core insulation (XLPE)
3 Inner covering (EPDM)
4 Sheath (HDPE black, UV-resistant)

Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal
(/km)
(A)
(A)
cross section
(mm2)

Cert
.....
..

Outer
diameter
(mm) ca.

.
..

Core identification:

coloured (HD 308 S2)

Test certificate:

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

NA2X2Y
4 x 25 RE

1.200

112

92

25.5

290

730

1000 T

4 x 25 RM

1.200

112

92

26.7

290

748

1000 T

4 x 35 RE

0.868

135

112

27.8

406

882

1000 T

4 x 35 RM

0.868

135

112

29.3

406

939

1000 T

4 x 50 SE

0.641

158

133

31.9

580

910

1000 T

4 x 50 SM

0.641

158

133

34.4

580

1,006

1000 T

4 x 70 SE

0.443

196

169

36.1

812

1,276

1000 T

4 x 70 SM

0.443

196

169

38.0

812

1,335

1000 T

4 x 95 SE

0.320

234

205

40.3

1,102

1,631

1000 T

4 x 95 SM

0.320

234

205

43.0

1,102

1,684

1000 T

4 x 120 SE

0.253

268

239

43.5

1,392

1,944

1000 T

4 x 120 SM

0.253

268

239

46.6

1,392

2,035

1000 T

4 x 150 SE

0.206

300

271

47.7

1,740

2,432

500 T

4 x 150 SM

0.206

300

271

50.4

1,740

2,573

500 T

4 x 185 SE

0.164

342

314

52.7

2,146

3,099

500 T

4 x 185 SM

0.164

342

314

57.0

2,146

3,254

500 T

4 x 240 SE

0.125

398

372

58.2

2,784

3,863

500 T

4 x 240 SM

0.125

398

372

63.2

2,784

4,044

500 T

1) basic rated current acc. to VDE 0276-603


Subject to technical changes.

Page 78

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

YAKY
Underground cable with PVC insulation and PVC sheath
Standard: PN-93/E-90401, PN-93/E-90400

Rated voltage:

0.6/1 kV

Usage:
The cables are intended for distribution of electrical energy. Power distribution cables in power stations, industrial installations and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted by the local
building regulations if no risk of any mechanical damage is to be
expected.

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
50 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
Fire properties:
flame retardant

4
3
2
1
Construction:
1 Aluminium conductor, round solid (RE), sector-shaped solid (SE),
round stranded (RM) resp. sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM or plastic tape)
4 Sheath (PVC black, UV-resistant)

Test certificate:

Cert
.....
..

.
..

.. .. ...
Sz JZD .
. . ..
.

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
EZ Czech Republic,
BBJ Poland

5
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

YAKY
4 x 16 RE

1.910

81

61

20.90

173

644

1000 T

4 x 25 RE

1.200

102

82

24.50

273

884

1000 T

4 x 35 RE

0.868

123

100

26.90

374

1,095

1000 T

4 x 50 SM

0.641

144

119

28.80

506

1,141

1000 T

4 x 70 SE

0.443

179

152

30.50

719

1,262

1000 T

4 x 70 SM

0.443

179

152

32.50

740

1,400

1000 T

4 x 95 SM

0.320

215

186

37.40

1,029

1,388

1000 T

3 x 120 + 70 SM/RM

0.253

245

216

41.00

1,188

2,046

1000 T

4 x 120 SE

0.253

245

216

38.50

1,239

2,158

1000 T

4 x 120 SM

0.253

245

216

41.00

1,255

2,316

1000 T

5 x 120 RM

0.253

245

216

50.60

1,800

2,926

1000 T

3 x 150 + 70 SM/RM

0.206/0.443

275

246

45.50

1,399

2,376

500 T

4 x 150 SM

0.206

275

246

45.50

1,607

2,667

500 T

3 x 185 + 95 SM/RM

0.164/0.320

313

285

50.40

1,772

2,988

500 T

4 x 185 SM

0.164

313

285

50.40

2,011

3,325

500 T

3 x 240 + 120 SM/RM

0.125/0.253

364

338

57.10

2,329

3,801

500 T

4 x 240 SE

0.125

364

338

53.10

2,583

4,414

500 T

4 x 240 SM

0.125

364

338

57.10

2,562

4,519

500 T

1) basic rated current acc. to PN-93/E-90401, PN-93/E-90400


Subject to technical changes.

Page 79

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

PVIKSALM
Underground cable with PVC insulation and PVC sheath
Standard: HD 603.3E S1
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
4
3
2
1
Construction:
1 Aluminium conductor, round solid (RE) resp. sector-shaped solid (SE)
2 Core insulation (PVC)
3 Inner covering (EPDM or plastic tape)
4 Sheath (PVC grey)

Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal
(/km)
(A)
(A)
cross section
(mm2)

Fire properties:
flame retardant

Outer
diameter
(mm) ca.

coloured (HD 603.3E S1)

(EN 50265-2-1,
IEC 60332-1)

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

180

707

1000 T

PVIKSALM
4 x 16 RE

1.910

81

61

22.3

4 x 25 RE

1.200

102

82

26.0

275

972

1000 T

4 x 50 SE

0.641

144

119

30.0

510

1,024

1000 T

4 x 95 SE

0.320

215

186

37.8

990

1,721

1000 T

4 x 150 SE

0.206

275

246

45.0

1,520

2,561

500 T

4 x 240 SE

0.125

364

338

55.1

2,585

4,038

500 T

1) basic rated current acc. to HD 603.3E S1


Subject to technical changes.

Page 80

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

PEXMAL
Underground cable with XLPE insulation and HDPE sheath
Standard: HD 603.5B S1
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations under severe mechanical stressing during installation and operation.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +90 C
max. +90C
max. +250 C/5 s

Bending radius (min.): 12 x of cable


Core identification:

coloured (HD 603.5B S1)

4
3
2
1
Construction:
1 Aluminium conductor, round solid (RE), resp. sector-shaped solid (SE)
2 Core insulation (VPE)
3 Inner covering (EPDM or plastic tape)
4 Sheath (HDPE grey)

5
Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal
(/km)
(A)
(A)
cross section
(mm2)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

484

1000 T

PEXMAL
4 x 25 RE

1.200

112

92

21.6

275

4 x 50 SE

0.641

158

133

27.8

510

766

1000 T

4 x 95 SE

0.320

234

205

35.2

990

1,344

1000 T

4 x 150 SE

0.206

300

271

43.2

1,520

2,045

500 T

4 x 240 SE

0.125

398

372

52.9

2,585

3,344

500 T

1) basic rated current acc. to HD 603.5B S1


Subject to technical changes.

Page 81

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

TFXP
Underground cable with XLPE insulation, HDPE sheath and PVC protective cover
Standard: HD 603.5M S1
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations under severe mechanical stressing during installation and operation.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +90 C
max. +90C
max. +250 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
5

coloured (HD 603.5M S1)

1
Fire properties:
flame retardant

Construction:
1 Aluminium conductor, round solid (RE) resp. sector-shaped solid (SE)
2 Core insulation (XLPE)
3 Inner covering (EPDM or plastic tape)
4 Sheath (HDPE green)
5 Protective cover (PVC green)

Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal
(/km)
(A)
(A)
cross section
(mm2)

(EN 50265-2-1,
IEC 60332-1)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

280

679

1000 T

TFXP
4 x 25 RM

1.200

112

92

25.8

4 x 50 SM

0.641

158

133

30.1

510

988

1000 T

4 x 95 SM

0.320

234

205

38.3

1,020

1,701

1000 T

4 x 150 SM

0.206

300

271

44.5

1,560

2,438

500 T

4 x 240 SM

0.125

398

372

56.1

2,590

3,812

500 T

1) basic rated current acc. to HD 603.5M S1


Subject to technical changes.

Page 82

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

AXMK
Underground cable with XLPE insulation and PVC sheath
Standard: HD 603.5D S1
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in
interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no whish of any mechanical
damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
30 C to +90 C
max. +90C
max. +250 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
4
3 2 1
Construction:
1 Aluminium conductor, round solid (RE), sector-shaped solid (SE),
round stranded (RM) resp. sector-shaped stranded (SM)
2 Core insulation (XLPE)
3 Inner covering (EPDM or plastic tape)
4 Sheath (PVC black, UV-resistant)

Fire properties:
flame retardant

coloured (HD 603.5D S1)

(EN 50265-2-1,
IEC 60332-1)

5
Number
Max. conductor Current rating Current rating
of cores x
resistance
in the ground1)
in the air1)
nominal
(/km)
(A)
(A)
cross section
(mm2)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

AXMK
4 x 16 RE

1.910

91

77

18.9

192

498

1000 T

4 x 25 RM

1.200

112

92

23.7

300

764

1000 T

4 x 35 SM

0.868

135

112

23.5

420

689

1000 T

4 x 50 SM

0.641

158

133

26.5

600

866

1000 T

4 x 70 SM

0.443

196

169

31.0

840

1,239

1000 T

4 x 95 SM

0.320

234

205

34.7

1,140

1,548

1000 T

4 x 120 SM

0.253

268

239

38.8

1,440

2,009

1000 T

4 x 150 SM

0.206

300

271

43.2

1,800

2,336

500 T

1) basic rated current acc. to HD 603.5D S1


Subject to technical changes.

Page 83

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

AYCWY
Underground cable with PVC insulation and PVC sheath, screened
Standard: MSZ IEC 502
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations when protection against shock
hazard voltages in the event of mechanical damage is required. The
concentric Ceander conductor can be used as PE or PEN conductor
and must not be cut when assembling branch tees.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
5 C to +50 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 15 x of cable


Core identification:

Fire properties:
flame retardant

Construction:
1 Aluminium conductor, round solid (RE), resp. sector-shaped
stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM)
4 Concentric screen (bare copper wires applied with changing
direction of lay) and counter helix (copper tape)
5 Sheath (PVC black, UV-resistant)

Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Max.
conductor
resistance
(/km)

Current
rating in the
ground1)
(A)

Current
rating
in the air1)
(A)

4 x 16 RE/10

1.910

76

63

Test certificate:

Cert
.....
..

Outer
diameter
(mm) ca.

.
..

coloured (MSZ)

(EN 50265-2-1,
IEC 60332-1)
MSZ Hungary

.. .. ...
Sz JZD .
. . ..
.

Al
weight
(kg/km)

Cu
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

189.0

110.0

849

500 T, 1000 T

AYCWY
23.0

4 x 25 RE/10

1.200

99

83

26.7

294.0

110.0

1,151

500 T, 1000 T

4 x 50 SM/25

0.641

142

124

35.3

588.0

260.0

1,679

500 T, 1000 T

4 x 95 SM/35

0.320

211

190

45.4

1,117.0

365.0

2,776

500 T, 1000 T

4 x 150 SM/50

0.206

270

252

53.6

1,764.0

525.0

3,747

500 T

4 x 240 SM/50

0.125

308

289

64.6

2,822.0

525.0

5,719

500 T

1) basic rated current acc. to MSZ IEC 502


Subject to technical changes.

Page 84

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

SZAMKAM
Underground cable with PVC insulation and PVC sheath, screened
Standard: MSZ IEC 502
Usage:
Power distribution cables in power stations, industrial installations and
switchgear, as well as in local mains. For fixed installation in interior
premises , cable ducts, in the open air, in water as permitted by the
local building regulations if no risk of any mechanical damage is to
be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
5 C to +50 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


5

Core identification:

Construction:
1 Aluminium conductor, round solid (RE), round stranded (RM) resp.
sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (plastic tape)
4 Screen (bare aluminium tape)
5 Sheath (PVC black, UV-resistant)

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
(/km)

Current rating in the


ground1)
(A)

Current rating in the


air1)
(A)

Fire properties:
flame retardant

Test certificate:

Cert
.....
..

coloured (MSZ)

(EN 50265-2-1,
IEC 60332-1)
MSZ Hungary

.. .. ...
.
.
.. . Sz JZD .
. . .

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

SZAMKAM
4 x 16 RE

1.910

76.0

63.0

21.2

188

503

500 T, 1000 T

4 x 25 RM

1.200

99.0

83.0

24.9

294

723

500 T, 1000 T

4 x 35 RM

0.868

118.0

102.0

27.5

412

898

500 T, 1000 T

4 x 50 SM

0.641

142.0

124.0

31.2

588

1,167

500 T, 1000 T

4 x 70 SM

0.443

176.0

158.0

35.7

823

1,535

500 T, 1000 T

4 x 95 SM

0.320

211.0

190.0

41.2

1117

2,034

500 T, 1000 T

4 x 120 SM

0.253

242.0

220.0

44.8

1411

2,601

500 T, 1000 T

4 x 150 SM

0.206

270.0

252.0

47.7

1764

3,013

500 T, 1000 T

4 x 185 SM

0.164

308.0

289.0

55.0

2164

3,676

500 T

4 x 240 SM

0.125

363.0

339.0

59.5

2823

4,724

500 T

1) basic rated current acc. to MSZ IEC 502


Subject to technical changes.

Page 85

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

PFSP
Underground cable with PVC insulation and PVC sheath, screened
Standard: HD 603.3J S1
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 15 C
30 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


5
4
3
2
1
Construction:
1 Aluminium conductor, round solid (RE) resp. sector-shaped
stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM + PVC or plastic tape)
4 Concentric screen (bare copper wires) and counter helix
(copper tape)
5 Sheath (PVC grey)

Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Max.
conductor
resistance
(/km)

Current
rating in the
ground1)
(A)

Current
rating
in the air1)
(A)

Core identification:
Fire properties:
flame retardant

Outer
diameter
(mm) ca.

coloured (HD 603.3J S1)

(EN 50265-2-1,
IEC 60332-1)

Al weight
(kg/km)

Cu weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

PFSP
3 x 16/10 RE

1.910

81

61

23.3

130

107

768

1000 T

4 x 16/10 RE

1.910

81

61

25.0

170

108

869

1000 T

3 x 25/10 RE

1.200

102

82

26.0

200

109

992

1000 T

4 x 25/10 RE

1.200

102

82

27.9

270

110

1,129

1000 T

3 x 50/16 SM

0.641

144

119

25.5

400

165

951

1000 T

4 x 50/16 SM

0.641

144

119

29.5

510

167

1,160

1000 T

3 x 95/35 SM

0.320

215

186

33.2

780

356

1,614

1000 T

4 x 95/35 SM

0.320

215

186

38.7

1,020

359

2,102

1000 T

3 x 150/50 SM

0.206

275

246

40.0

1,240

490

2,505

500 T

4 x 150/50 SM

0.206

275

246

46.8

1,560

493

3,030

500 T

3 x 240/70 SM

0.125

364

338

49.9

2,020

683

3,841

500 T

4 x 240/70 SM

0.125

364

338

58.8

2,590

688

4,728

500 T

1) basic rated current acc. to HD 603.3J S1


Subject to technical changes.

Page 86

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

TFSP
Underground cable with XLPE insulation and PVC sheath, screened
Standard: HD 603.5J S1
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 15 C
30 C to +90 C
max. +90C
max. +250 C/5 s

Bending radius (min.): 12 x of cable


Core identification:

5
4
3
2
1
Construction:
1 Aluminium conductor, round solid (RE) resp. sector-shaped
stranded (SM)
2 Core insulation (XLPE)
3 Inner covering (EPDM + PVC or plastic tape)
4 Concentric screen (bare copper wires) and counter helix
(copper tape)
5 Sheath (PVC grey)

Fire properties:
flame retardant

coloured (HD 603.5J S1)

(EN 50265-2-1,
IEC 60332-1)

Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Max.
conductor
resistance
(/km)

Current
rating in the
ground1)
(A)

Current
rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Al weight
(kg/km)

Cu weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

3 x 16/10 RE

1.910

91

77

130

107

737

1000 T

4 x 16/10 RE

1.910

91

77

24.3

170

108

824

1000 T

3 x 25/10 RE

1.200

112

92

26.0

200

109

952

1000 T

4 x 25/10 RE

1.200

112

92

27.9

270

110

1,075

1000 T

3 x 50/16 SM

0.641

158

133

25.5

400

165

879

1000 T

4 x 50/16 SM

0.641

158

133

29.5

510

167

1,064

1000 T

3 x 95/35 SM

0.320

234

205

33.2

780

356

1,508

1000 T

4 x 95/35 SM

0.320

234

205

38.7

1,020

359

1,961

1000 T

3 x 150/50 SM

0.206

300

271

40.0

1,240

490

2,339

500 T

4 x 150/50 SM

0.206

300

271

46.8

1,560

493

2,809

500 T

3 x 240/70 SM

0.125

398

372

49.9

2,020

683

3,590

500 T

4 x 240/70 SM

0.125

398

372

58.8

2,590

688

4,393

500 T

TFSP
22.7

1) basic rated current acc. to HD 603.5J S1


Subject to technical changes.

Page 87

- >> ENERGY CABLES 0.6/1 k V

SKW | PRAKAB | Products

AKKJ
Underground cable with PVC insulation and PVC sheath, screened
Standard: HD 603.3L S1
Usage:
Power distribution cables in power stations, industrial installations
and switchgear, as well as in local mains. For fixed installation in interior premises, cable ducts, in the open air, in water as permitted
by the local building regulations if no risk of any mechanical damage is to be expected.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 15 C
30 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 12 x of cable


5
4
3
2
1
Construction:
1 Aluminium conductor, sector-shaped stranded (SM)
2 Core insulation (PVC)
3 Inner covering (EPDM + PVC or plastic tape)
4 Concentric screen (bare copper wires) and counter helix
(copper tape)
5 Sheath (PVC black, UV-resistant)

Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Max.
conductor
resistance
(/km)

Current
rating in the
ground1)
(A)

Current
rating
in the air1)
(A)

Core identification:
Fire properties:
flame retardant

Outer
diameter
(mm) ca.

coloured (HD 603.3L S1)

(EN 50265-2-1,
IEC 60332-1)

Al weight
(kg/km)

Cu weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

AKKJ
3 x 50 SM/15

0.641

144

119

28.1

450

150

1,130

1000 T

3 x 70 SM/21

0.443

179

152

31.9

630

210

1,446

1000 T

3 x 95 SM/29

0.320

215

186

35.1

855

290

1,794

1000 T

3 x 150 SM/41

0.206

275

246

42.4

1,350

410

2,568

500 T

1) basic rated current acc. to HD 603.3L S1


Subject to technical changes.

Page 88

- >> ENERGY CABLES 10-30 KV

SKW | PRAKAB | Products

N2XS(F)2Y
Underground cable with XLPE insulation and HDPE sheath, longitudinally water-proof
Standard: DIN VDE 0276 Part 620 (HD 620)
Usage:
For fixed installation for high requirements in interior premises, in the
ground subject to external effects of moisture, in the open air and in
cable ducts for industrial and distribution mains as permitted by
the local building regulations under severe mechanical stressing
during installation and operation.

Rated voltage:

6/10

12/20 18/30 kV

Test voltage:

18

36

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

48 kVeff

min. 20 C
20 C to +80 C
max. +90 C
max. +250 C/5 s

Bending radius (min.): 15 x of cable


Test certificate:

Cert
.....
..

.
..

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Construction:
1 Copper conductor; round stranded compacted (RMV)
2 Inner semi-conductive layer (conductive XLPE)
3 Core insulation (XLPE)
4 Outer semi-conductive layer (conductive XLPE), taped with
a conductive tape
5 Screen (bare copper wires) and counter helix (copper tape)
6 Swelling tape under and over screen
7 Sheath (HDPE black, UV-resistant)

6
Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Mutual
capacitance
(nF/km)

Max.
conductor
resistance
(/km)

Current rating in the


ground1)
(A)

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

N2XS(F)2Y 6/10 kV
1 x 35 RM/16

0.24

0.5240

187

197

26

540

915

500 T, 1000 T

1 x 50 RM/16

0.26

0.3870

220

236

27

690

1,120

500 T, 1000 T

1 x 70 RM/16

0.30

0.2680

268

294

28

890

1,330

500 T, 1000 T

1 x 95 RM/16

0.31

0.1930

320

358

30

1,140

1,620

500 T, 1000 T

1 x 120 RM/16

0.34

0.1530

363

413

32

1,390

1,870

500 T, 1000 T

1 x 150 RM/25

0.39

0.1240

405

468

33

1,795

2,260

500 T, 1000 T

1 x 185 RM/25

0.42

0.0991

456

535

35

2,145

2,630

500 T, 1000 T

1 x 240 RM/25

0.47

0.0754

526

631

38

2,695

3,220

500 T, 1000 T

1 x 300 RM/25

0.51

0.0601

591

722

40

3,295

3,810

500 T, 1000 T

1 x 400 RM/35

0.57

0.0470

662

827

43

4,410

4,850

500 T, 1000 T

1 x 500 RM/35

0.63

0.0366

744

949

46

5,410

5,800

500 T, 1000 T

1 x 35 RM/16

0.16

0.5240

189

200

30

540

1,075

500 T, 1000 T

1 x 50 RM/16

0.18

0.3870

222

239

31

690

1,270

500 T, 1000 T

1 x 70 RM/16

0.20

0.2680

271

297

33

890

1,520

500 T, 1000 T

1 x 95 RM/16

0.22

0.1930

323

361

35

1,140

1,780

500 T, 1000 T

N2XS(F)2Y 12/20 kV

Page 89

- >> ENERGY CABLES 10-30 KV

SKW | PRAKAB | Products

N2XS(F)2Y
Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Mutual
capacitance
(nF/km)

Max.
conductor
resistance
(/km)

Current rating in the


ground1)
(A)

1 x 120 RM/16

0.24

0.1530

367

1 x 150 RM/25

0.26

0.1240

1 x 185 RM/25

0.27

1 x 240 RM/25

0.31

1 x 300 RM/25
1 x 400 RM/35
1 x 500 RM/35

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

416

36

1,390

2,090

500 T, 1000 T

409

470

37

1,795

2,460

500 T, 1000 T

0.0991

461

538

39

2,145

2,840

500 T, 1000 T

0.0754

532

634

42

2,695

3,400

500 T, 1000 T

0.33

0.0601

599

724

44

3,295

4,150

500 T, 1000 T

0.37

0.0470

671

829

47

4,410

5,190

500 T, 1000 T

0.41

0.0366

754

953

50

5,410

6,170

500 T, 1000 T

N2XS(F)2Y 12/20 kV

N2XS(F)2Y 18/30 kV
1 x 50 RM/16

0.14

0.3870

225

241

36

690

1,520

500 T, 1000 T

1 x 70 RM/16

0.15

0.2680

274

299

38

890

1,790

500 T, 1000 T

1 x 95 RM/16

0.17

0.1930

327

363

40

1,140

2,070

500 T, 1000 T

1 x 120 RM/16

0.18

0.1530

371

418

41

1,390

2,360

500 T, 1000 T

1 x 150 RM/25

0.19

0.1240

414

472

42

1,795

2,760

500 T, 1000 T

1 x 185 RM/25

0.21

0.0991

466

539

44

2,145

3,170

500 T, 1000 T

1 x 240 RM/25

0.23

0.0754

539

635

47

2,695

3,860

500 T, 1000 T

1 x 300 RM/25

0.25

0.0601

606

725

49

3,295

4,490

500 T, 1000 T

1 x 400 RM/35

0.27

0.0470

680

831

52

4,410

5,580

500 T

1 x 500 RM/35

0.30

0.0366

765

953

55

5,410

6,600

500 T

1) basic rated current acc. to VDE 0276-620 (HD 620)


Subject to technical changes.

Page 90

- >> ENERGY CABLES 10-30 KV

SKW | PRAKAB | Products

NA2XS(F)2Y
Underground cable with XLPE insulation and HDPE sheath, longitudinally water-proof
Standard: DIN VDE 0276 Part 620 (HD 620)
Usage:
For fixed installation for high requirements in interior premises, in the
ground subject to external effects of moisture, in the open air and in
cable ducts for industrial and distribution mains as permitted by
the local building regulations under severe mechanical stressing
during installation and operation.

Rated voltage:

6/10

12/20 18/30 kV

Test voltage:

18

36

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

48 kVeff

min. 20 C
20 C to +80 C
max. +90 C
max. +250 C/5 s

Bending radius (min.): 15 x of cable


Test certificate:

Cert
.....
..

.
..

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

7
6
5
4
3
2
1
Construction:
1 Aluminium conductor; round stranded compacted (RMV)
2 Inner semi-conductive layer (conductive XLPE)
3 Core insulation (XLPE)
4 Outer semi-conductive layer (conductive XLPE), taped with
a conductive tape
5 Screen (bare copper wires) and counter helix (copper tape)
6 Swelling tape under and over screen
7 Sheath (HDPE black, UV-resistant)

6
Number of cores x Mutual ca- Max. con- Current ra- Current
nominal cross
pacitance
ductor
ting in the
rating
section/cross
(nF/km)
resistance ground1)
in the air1)
section of screen
/km)
(
(A)
(A)
(mm2)

Outer
diameter
(mm) ca.

Al
weight
(kg/km)

Cu
weight
(kg/km)

Total
weight
(kg/km)
ca.

Standard
lenghts/
packing
(m)

NA2XS(F)2Y 6/10 kV
1 x 35 RM/16

0.24

0.8680

145

153

26

103

190

650

500 T, 1000 T

1 x 50 RM/16

0.26

0.6410

171

183

27

147

190

750

500 T, 1000 T

1 x 70 RM/16

0.30

0.4430

208

228

28

206

190

850

500 T, 1000 T

1 x 95 RM/16

0.31

0.3200

248

278

30

279

190

950

500 T, 1000 T

1 x 120 RM/16

0.34

0.2530

283

321

32

353

190

1,100

500 T, 1000 T

1 x 150 RM/25

0.39

0.2060

315

364

33

441

295

1,300

500 T, 1000 T

1 x 185 RM/25

0.42

0.1640

357

418

35

544

295

1,450

500 T, 1000 T

1 x 240 RM/25

0.47

0.1250

413

494

38

706

295

1,600

500 T, 1000 T

1 x 300 RM/25

0.51

0.1000

466

568

40

882

295

1,850

500 T, 1000 T

1 x 400 RM/35

0.57

0.0778

529

660

43

1,176

410

2,350

500 T, 1000 T

1 x 35 RM/16

0.16

0.8680

146

155

30

103

190

850

500 T, 1000 T

1 x 50 RM/16

0.18

0.6410

172

185

31

147

190

900

500 T, 1000 T

1 x 70 RM/16

0.20

0.4430

210

231

33

206

190

1,050

500 T, 1000 T

1 x 95 RM/16

0.22

0.3200

251

280

35

279

190

1,150

500 T, 1000 T

1 x 120 RM/16

0.24

0.2530

285

323

36

353

190

1,300

500 T, 1000 T

NA2XS(F)2Y 12/20 kV

Page 91

- >> ENERGY CABLES 10-30 KV

SKW | PRAKAB | Products

NA2XS(F)2Y
Number of cores x Mutual ca- Max. con- Current ra- Current
nominal cross
pacitance
ductor
ting in the
rating
section/cross
(nF/km)
resistance ground1)
in the air1)
section of screen
/km)
(
(A)
(A)
(mm2)

Outer
diameter
(mm) ca.

Al
weight
(kg/km)

Cu
weight
(kg/km)

Total
weight
(kg/km)
ca.

Standard
lenghts/
packing
(m)

NA2XS(F)2Y 12/20 kV
1 x 150 RM/25

0.26

0.2060

319

366

37

441

295

1,500

500 T, 1000 T

1 x 185 RM/25

0.27

0.1640

361

420

39

544

295

1,650

500 T, 1000 T

1 x 240 RM/25

0.31

0.1250

417

496

42

706

295

1,850

500 T, 1000 T

1 x 300 RM/25

0.33

0.1000

471

569

44

882

295

2,100

500 T, 1000 T

1 x 400 RM/35

0.37

0.0778

535

660

47

1,176

410

2,550

500 T, 1000 T

NA2XS(F)2Y 18/30 kV
1 x 50 RM/16

0.14

0.6410

174

187

36

147

190

1,150

500 T, 1000 T

1 x 70 RM/16

0.15

0.4430

213

232

38

206

190

1,300

500 T, 1000 T

1 x 95 RM/16

0.17

0.3200

254

282

40

279

190

1,450

500 T, 1000 T

1 x 120 RM/16

0.18

0.2530

289

325

41

353

190

1,550

500 T, 1000 T

1 x 150 RM/25

0.19

0.2060

322

367

42

441

295

1,800

500 T, 1000 T

1 x 185 RM/25

0.21

0.1640

364

421

44

544

295

1,950

500 T, 1000 T

1 x 240 RM/25

0.23

0.1250

422

496

47

706

295

2,200

500 T, 1000 T

1 x 300 RM/25

0.25

0.1000

476

568

49

882

295

2,500

500 T, 1000 T

1 x 400 RM/35

0.27

0.0778

541

659

52

1,176

410

3,000

500 T

1) basic rated current acc. to VDE 0276-620 (HD 620)


Subject to technical changes.

Page 92

- >> RAILWAY SIGNALLING CABLES

SKW | PRAKAB | Products

A2Y2YB2Y
Signalling cable, unscreened, armoured
Standard: Dt. Bundesbahn-Norm
Usage:
Safety and control cable for fixed installation in railway installations.

Rated voltage:

max. 300 Veff

Test voltage:

core/core 2500 Veff

Temperature range:
laying temperature:
min. 10 C
operating temperature: 40 C to +60 C
conductor temperature: max. +70 C
Bending radius (min.): 10 x of cable
6

Core identification:

colour-less with tracer


wire (blue in each layer)

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PE), cores stranded in layers
3 Inner covering (plastic tape)
4 Sheath (PE black)
5 Amouring (galvanized steel tape)
6 Sheath (PE black, UV-resistant)

Electrical parameters
Conductor diameter

(mm)

0.9

1.4

1.8

(/km)

27.8

11.5

6.9

Insulation resistance, min.

(M.km)

10,000

10,000

10,000

Mutual capacitance, max.

(nF/km)

115

145

145

Loop resistance, max.

Number of cores x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

2 x 1 x 0.9

9.2

98

500 T, 1000 T

4 x 1 x 0.9

9.9

122

500 T, 1000 T

7 x 1 x 0.9

11.0

158

500 T, 1000 T

10 x 1 x 0.9

12.7

203

500 T, 1000 T

14 x 1 x 0.9

13.4

246

500 T, 1000 T

20 x 1 x 0.9

14.5

307

500 T, 1000 T

24 x 1 x 0.9

16.2

359

500 T, 1000 T

30 x 1 x 0.9

16.9

415

500 T, 1000 T

40 x 1 x 0.9

18.0

503

500 T, 1000 T

50 x 1 x 0.9

20.3

610

500 T, 1000 T

60 x 1 x 0.9

21.4

698

500 T, 1000 T

80 x 1 x 0.9

23.9

881

500 T, 1000 T

100 x 1 x 0.9

26.8

1,068

500 T, 1000 T

120 x 1 x 0.9

27.9

1,239

500 T, 1000 T

140 x 1 x 0.9

33.8

1,439

500 T, 1000 T

A2Y2YB2Y

Page 93

SKW | PRAKAB | Products

- >> RAILWAY SIGNALLING CABLES

A2Y2YB2Y
Number of cores x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

4 x 1 x 1.4

12.7

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

203

500 T, 1000 T

A2Y2YB2Y

7 x 1 x 1.4

14.4

281

500 T, 1000 T

10 x 1 x 1.4

17.3

378

500 T, 1000 T

14 x 1 x 1.4

18.5

473

500 T, 1000 T

20 x 1 x 1.4

20.2

609

500 T, 1000 T

24 x 1 x 1.4

23.1

725

500 T, 1000 T

30 x 1 x 1.4

23.7

844

500 T, 1000 T

40 x 1 x 1.4

26.0

1,026

500 T, 1000 T

50 x 1 x 1.4

29.6

1,306

500 T, 1000 T

60 x 1 x 1.4

32.2

1,547

500 T, 1000 T

4 x 1 x 1.8

13.9

260

500 T, 1000 T

7 x 1 x 1.8

15.9

373

500 T, 1000 T

10 x 1 x 1.8

19.3

509

500 T, 1000 T

14 x 1 x 1.8

20.7

648

500 T, 1000 T

20 x 1 x 1.8

22.7

850

500 T, 1000 T

24 x 1 x 1.8

26.1

1,015

500 T, 1000 T

30 x 1 x 1.8

27.7

1,217

500 T, 1000 T

40 x 1 x 1.8

29.7

1,536

500 T, 1000 T

Note: in addition the product groups A-2Y2YV, AJ-2Y2YDB2Y, A-2Y(L)2YB2Y and AJ-2Y(L)2YDB2Y can be offered.
Subject to technical changes.

Page 94

- >> RAILWAY SIGNALLING CABLES

SKW | PRAKAB | Products

SwCLT
Signalling cable, unscreened, armoured
Standard: SBB-Norm
Usage:
Safety and control cable for fixed installation in railway installations

Rated voltage:

max. 500 Veff

Test voltage:

core/core 2000 Veff

Temperature range:
laying temperature:
min. 10 C
operating temperature: 30 C to +60 C
conductor temperature: max. +70 C
Bending radius (min.): 10 x of cable
6

Core identification:

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PE), cores star quaded and quads stranded
in layers
3 Inner covering (plastic tape)
4 Sheath (PE black)
5 Armouring (galvanized steel tape)
6 Sheath (PE black, UV-resistant)

colour-less, with tracer


and direction quad in
each layer

Electrical parameters
Conductor diameter
Loop resistance, max.
Insulation resistance, min.
Mutual capacitance, max.
Capacitance unbalance K1, max. at 800 Hz

(mm)

1.0

1.5

(/km)

47.0

20.9

(M.km)

10,000

10,000

(nF/km)

42

52

(pF/300 m)

400

400

7
Number of quads x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

1 x 4 x 1.0

12.7

204

500 T, 1000 T

2 x 4 x 1.0

18.8

401

500 T, 1000 T

3 x 4 x 1.0

20.2

455

500 T, 1000 T

4 x 4 x 1.0

21.8

526

500 T, 1000 T

5 x 4 x 1.0

22.6

636

500 T, 1000 T

7 x 4 x 1.0

25.8

798

500 T, 1000 T

10 x 4 x 1.0

32.2

1,024

500 T, 1000 T

15 x 4 x 1.0

36.4

1,326

500 T, 1000 T

20 x 4 x 1.0

39.2

1,669

500 T, 1000 T

25 x 4 x 1.0

47.8

2,076

500 T

30 x 4 x 1.0

50.0

2,353

500 T

1 x 4 x 1.5

12.9

232

500 T, 1000 T

2 x 4 x 1.5

20.7

491

500 T, 1000 T

SwCLT

Page 95

SKW | PRAKAB | Products

- >> RAILWAY SIGNALLING CABLES

SwCLT
Number of quads x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

3 x 4 x 1.5

22.5

648

500 T, 1000 T

4 x 4 x 1.5

23.4

731

500 T, 1000 T

5 x 4 x 1.5

24.7

852

500 T, 1000 T

SwCLT

7 x 4 x 1.5

26.7

1,033

500 T, 1000 T

10 x 4 x 1.5

35.8

1,521

500 T, 1000 T

15 x 4 x 1.5

39.3

2,161

500 T, 1000 T

20 x 4 x 1.5

45.2

2,640

500 T, 1000 T

25 x 4 x 1.5

50.0

3,261

500 T

30 x 4 x 1.5

54.0

3,756

500 T

Subject to technical changes.

Page 96

- >> RAILWAY SIGNALLING CABLES

SKW | PRAKAB | Products

TD 59PT
Signalling cable, unscreened, armoured
Standard: SKW-internal standard adapted to JUS
Usage:
Safety and control cable for fixed installation in infrastructure signalling installations (e.g. railway installations, motorways). Suitable for
fixed installation in the open air or in cable ducts.

Rated voltage:

max. 225 Veff

Test voltage:

core/core 500 Veff


core/screen 2000 Veff

Temperature range:
laying temperature:
min. 5 C
operating temperature: 40 C to +70 C
conductor temperature: max. +70 C
Bending radius (min.): 10 x of cable
7

Core identification:

coloured

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (foam skin PE), cores star quaded and quads
stranded in groups, core stranding petrol jelly filled
3 Inner covering (plastic tape)
4 Screen (copolymer laminated aluminium tape which is welded
to the PE sheath)
5 Sheath (PE black)
6 Armouring (galvanized steel tape, two layers)
7 Sheath (PE black, UV-resistant)

Electrical parameters
Conductor diameter

(mm)

0.8

0.9

1.2

Loop resistance, max.

(/km)

73.2

56.6

31.8

Resistance difference

(/km)

0.6

0.6

0.6

Insulation resistance, min.

(M.km)

10,000

10,000

10,000

Mutual capacitance, max.

(nF/km)

35.7

35.7

36.7

Capacitance unbalance K1, max. at 800 Hz

(pF/426 m)

100

100

100

Capacitance unbalance K9-12, max. at 800 Hz

(pF/426 m)

100

100

100

Capacitance unbalance E1-E2 at 800 Hz

(pF/426 m)

550

550

550

Number of quads x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

3 x 4 x 0.8

20.2

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

655

500 T, 1000 T

TD 59PT

5 x 4 x 0.8

22.2

808

500 T, 1000 T

10 x 4 x 0.8

27.3

1,143

500 T, 1000 T

15 x 4 x 0.8

31.8

1,488

500 T, 1000 T

20 x 4 x 0.8

36.2

2,140

500 T, 1000 T

3 x 4 x 0.9

24.2

839

500 T, 1000 T

5 x 4 x 0.9

26.7

1,035

500 T, 1000 T

Page 97

SKW | PRAKAB | Products

- >> RAILWAY SIGNALLING CABLES

TD 59PT
Number of quads x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

10 x 4 x 0.9

32.8

1,464

500 T, 1000 T

15 x 4 x 0.9

38.2

1,905

500 T, 1000 T

20 x 4 x 0.9

43.5

2,740

500 T, 1000 T

3 x 4 x 1.2

29.0

1,166

500 T, 1000 T

5 x 4 x 1.2

32.0

1,438

500 T, 1000 T

10 x 4 x 1.2

39.4

2,034

500 T, 1000 T

15 x 4 x 1.2

45.8

2,647

500 T, 1000 T

20 x 4 x 1.2

52.2

3,808

500 T

TD 59PT

Note: This type is also available with additional protection against interference, other dimensions on request.
Subject to technical changes.

Page 98

- >> RAILWAY SIGNALLING CABLES

SKW | PRAKAB | Products

BRQKAQAhVQ
Signalling cable, screened, armoured, protected against interference
Standard: MV.-Norm
Usage:
Safety and control cable for fixed installation in infrastructure signalling installations (e.g. railway installations, motorways). Suitable for
fixed installation in the open air or in cable ducts.

Test voltage:

core/core 2000 Veff


core/screen 3000 Veff

Temperature range:
laying temperature:
min. 10 C
operating temperature: 40 C to +70 C
conductor temperature: max. +70 C
Bending radius (min.): 10 x of cable
Core identification:
transparent, with tracer (red) and direction (blue)
core in each layer

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PE), cores stranded in layers
3 Inner covering (plastic tape)
4 Screen (PE laminated aluminium tape)
5 Sheath (PE black)
6 Screen (bare aluminium tape)
7 Armouring (galvanized steel tape, two layers)
8 Sheath (PE black, UV-resistant)
Electrical parameters
Conductor diameter

(mm)

Loop restistance, max.


Insulation resistance, min.

1.0

1.5

(/km)

23.39

10.03

(M.km)

10,000

10,000

7
Number of cores x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

2x1x1

17.0

312

500 T, 1000 T

4x1x1

17.0

330

500 T, 1000 T

7x1x1

17.0

366

500 T, 1000 T

10 x 1 x 1

17.5

418

500 T, 1000 T

14 x 1 x 1

18.3

450

500 T, 1000 T

21 x 1 x 1

19.5

523

500 T, 1000 T

30 x 1 x 1

21.7

628

500 T, 1000 T

37 x 1 x 1

22.6

772

500 T, 1000 T

48 x 1 x 1

26.5

937

500 T, 1000 T

61 x 1 x 1

27.7

1,082

500 T, 1000 T

75 x 1 x 1

30.9

1,297

500 T, 1000 T

91 x 1 x 1

32.1

1,473

500 T, 1000 T

2 x 1 x 1.5

17.0

353

500 T, 1000 T

BRQKAQAhVQ

Page 99

- >> RAILWAY SIGNALLING CABLES

SKW | PRAKAB | Products

BRQKAQAhVQ
Number of cores x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

4 x 1 x 1.5

17.0

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

358

500 T, 1000 T

BRQKAQAhVQ

7 x 1 x 1.5

17.0

399

500 T, 1000 T

10 x 1 x 1.5

19.5

517

500 T, 1000 T

14 x 1 x 1.5

20.5

607

500 T, 1000 T

21 x 1 x 1.5

22.0

780

500 T, 1000 T

30 x 1 x 1.5

25.9

1,034

500 T, 1000 T

37 x 1 x 1.5

27.4

1,196

500 T, 1000 T

48 x 1 x 1.5

30.4

1,474

500 T, 1000 T

61 x 1 x 1.5

31.9

1,755

500 T, 1000 T

75 x 1 x 1.5

35.8

2,122

500 T, 1000 T

91 x 1 x 1.5

37.3

2,460

500 T, 1000 T

Subject to technical changes.

Page 100

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

JY(St)Y...Lg
Installation cable, screened
Standard: VDE 0815
Usage:
Installation cable for use in telecommunications installations and related installations. Preferably for installation in interior premises but
also for fixed installation on exterior walls of buildings. However, not
suitable for power installations or direct burial.

Rated voltage:

max. 300 Vss ( 0.8


briefly max. 600 Vss)

Test voltage:

core/core 800 Veff


core/screen 800 Veff

Temperature range:
laying temperature:
min. 5 C
operating temperature: fixed 30 C to +70 C
conductor temperature: max. +70 C
5

Bending radius (min.): 7.5 x of cable

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PVC), cores pair stranded, pairs stranded in layers
3 Inner covering (plastic tape)
4 Screen (plastic laminated aluminium tape with drain wire)
5 Sheath (PVC grey)

Cert
.....
..

.
..

Core identification:

coloured (VDE 0815)

Test certificate:

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Electrical parameters
Conductor diameter
Loop resistance, max.
Insulation resistance, min.

(mm)

0.6

0.8

(/km)

130

73

(M.km)

100

100

Mutual capacitance, max. at 800 Hz (until 4 pairs)

(nF/km)

120

120

Mutual capacitance, max. at 800 Hz

(nF/km)

100

100

Capacitance unbalance, max . at 800 Hz (100 % of values)

(pF/100 m)

300

300

Capacitance unbalance, max. at 800 Hz (80 % of values)

(pF/100 m)

500

500

8
Number of cores x
nominal cross section
(mm2)

Outer
diameter
(mm) ca.

2 x 2 x 0.6

5.2

3 x 2 x 0.6
4 x 2 x 0.6

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

13

42

100 R, 500 Sp, 1000 Sp

5.9

19

50

100 R, 500 Sp, 1000 Sp

6.9

25

59

100 R, 500 Sp, 1000 Sp

5 x 2 x 0.6

8.0

30

84

100 R, 500 Sp, 1000 Sp

6 x 2 x 0.6

8.5

35

89

100 R, 500 Sp, 1000 Sp

10 x 2 x 0.6

9.5

59

127

500 Sp, 1000 Sp

12 x 2 x 0.6

10.0

71

145

500 Sp, 1000 Sp

16 x 2 x 0.6

12.0

93

198

500 Sp, 1000 Sp

20 x 2 x 0.6

13.7

115

222

500 T, 1000 T

30 x 2 x 0.6

14.6

172

308

500 T, 1000 T

JY(St)Y...Lg

Page 101

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

JY(St)Y...Lg
Number of cores x
nominal cross section
(mm2)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

JY(St)Y...Lg
40 x 2 x 0.6

17.5

228

383

500 T, 1000 T

50 x 2 x 0.6

19.8

286

489

500 T, 1000 T

60 x 2 x 0.6

21.9

342

574

500 T, 1000 T

100 x 2 x 0.6

25.1

569

899

500 T, 1000 T

1 x 2 x 0.8

5.5

11

38

100 R, 500 Sp, 1000 Sp

2 x 2 x 0.8

7.0

22

60

100 R, 500 Sp, 1000 Sp

3 x 2 x 0.8

8.5

31

84

100 R, 500 Sp, 1000 Sp

4 x 2 x 0.8

9.2

42

102

100 R, 500 Sp, 1000 Sp

5 x 2 x 0.8

10.3

52

132

100 R, 500 Sp, 1000 Sp

6 x 2 x 0.8

11.5

62

155

100 R, 500 Sp, 1000 Sp

10 x 2 x 0.8

12.4

103

206

500 T, 1000 T

12 x 2 x 0.8

14.4

124

257

500 T, 1000 T

16 x 2 x 0.8

16.7

164

339

500 T, 1000 T

20 x 2 x 0.8

17.0

203

365

500 T, 1000 T

30 x 2 x 0.8

20.0

304

561

500 T, 1000 T

40 x 2 x 0.8

24.0

404

751

500 T, 1000 T

50 x 2 x 0.8

26.2

506

909

500 T, 1000 T

60 x 2 x 0.8

30.0

606

1,105

500 T, 1000 T

100 x 2 x 0.8

39.0

1,008

1,750

500 T, 1000 T

Note: construction in groups (Bd) on request


Subject to technical changes.

Page 102

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

TPV
Installation cable, screened
Standard: GOST 22498-88, GOST 51 311-99
Usage:
The cables are suitable for fixed installation in buildings with
telecommunications installations.

Rated voltage:

145 V

Test voltage:

core/core 1500 Veff


core/screen 3000 Veff

Temperature range:
laying temperature:
20 C to +60 C
operating temperature: 40 C to +60 C
Bending radius (min.): 10 x of cable
5

1
Core identification:

Aufbau
1 Copper conductor, round solid (RE)
2 Core insulation (PE), cores pair stranded, 5 pairs stranded in basic
groups.These are stranded in main groups (10 pairs) and further
stranded in layers.
3 Inner covering (plastic tape)
4 Screen (plastic laminated aluminium tape with drain wire)
5 Sheath (PVC grey)

Fire properties:
flame retardant

coloured
(GOST: 51 311-99)

(EN 50265-2-1,
IEC 60332-1)

Electrical parameters
Conductor diameter

(mm)

0.4

0.5

0.64

(/km)

278

180

110

Insulation resistance, min.

(M.km)

6,500

6,500

6,500

Mutual capacitance, max.

(nF/km)

50

50

50

Loop resistance, max.

Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

TPV
10 x 2 x 0.4

10.9

25

114

2000 T

20 x 2 x 0.4

13.1

50

167

2000 T

30 x 2 x 0.4

15.5

74

231

2000 T

50 x 2 x 0.4

18.9

124

344

1000 T

100 x 2 x 0.4

24.9

247

602

1000 T

10 x 2 x 0.5

12.3

39

144

2000 T

20 x 2 x 0.5

15.7

77

237

2000 T

30 x 2 x 0.5

17.8

116

308

2000 T

50 x 2 x 0.5

22.2

193

481

1000 T

100 x 2 x 0.5

29.4

385

852

1000 T

10 x 2 x 0.64

13.9

64

189

2000 T

20 x 2 x 0.64

17.9

127

319

2000 T

30 x 2 x 0.64

20.5

190

424

2000 T

50 x 2 x 0.64

26.5

316

700

1000 T

100 x 2 x 0.64

35.2

631

1,252

1000 T

Subject to technical changes.

Page 103

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

TPVBG
Installation cable, screened, armoured
Standard: GOST 22498-88, GOST 51 311-99
Usage:
The cables are suitable for fixed installation in buildings with
telecommunications installations. They are resistant to increased
mechanical pressure.

Rated voltage:

145 V

Test voltage:

core/core 1500 Veff


core/screen 3000 Veff
core/armouring 5000 Veff

Temperature range:
laying temperature:
20 C to +60 C
operating temperature: 40 C to +60 C
Bending radius (min.): 10 x of cable

6
5
4
3
2
1
Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PE), cores pair stranded, 5 pairs stranded in basic
groups.These are stranded in main groups (10 pairs) and further
stranded in layers.
3 Inner covering (plastic tape)
4 Screen (plastic laminated aluminium tape with drain wire)
5 Sheath (PVC grey)
6 Amouring (2 steel tapes with corrosion-resistant surface)

Core identification:

Fire properties:
flame retardant

coloured
(GOST: 51 311-99)

(EN 50265-2-1,
IEC 60332-1)

Electrical parameters
Conductor diameter

(mm)

Loop resistance, max.

0.4

0.5

0.64

(/km)

278

180

110

Insulation resistance, min.

(M.km)

6,500

6,500

6,500

Mutual capacitance, max.

(nF/km)

50

50

50

Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

TPVBG
10 x 2 x 0.4

14.5

25

291

2000 T

20 x 2 x 0.4

15.7

50

371

2000 T

30 x 2 x 0.4

17.8

74

456

2000 T

50 x 2 x 0.4

20.9

124

610

1000 T

100 x 2 x 0.4

26.3

247

1,132

1000 T

10 x 2 x 0.5

15.7

39

338

2000 T

20 x 2 x 0.5

18.0

77

464

2000 T

30 x 2 x 0.5

19.9

116

560

2000 T

50 x 2 x 0.5

23.9

193

960

1000 T

100 x 2 x 0.5

31.2

385

1,466

1000 T

10 x 2 x 0.64

17.1

64

402

2000 T

20 x 2 x 0.64

20.0

127

573

2000 T

30 x 2 x 0.64

22.4

190

709

1000 T

50 x 2 x 0.64

28.6

316

1,260

1000 T

100 x 2 x 0.64

36.5

631

1,973

1000 T

Subject to technical changes.

Page 104

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

F2YA2Y
Underground cable, screened
Standard: adapted to Telecom Austria-Standard
Usage:
Underground cable for use in telecommunications installations
and related installations. Suitable for installation underground,
in water, cable ducts etc.

Rated voltage:

max. 200 Veff

Test voltage:

core/core 500 Veff


core/screen 2000 Veff

Temperature range:
laying temperature:
min. 20 C
operating temperature: in motion 20 C to +50 C
fixed 20 C to +70 C
5

Bending radius (min.): 10 x of cable

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PE), cores pair stranded, pairs stranded in layers
3 Inner covering (plastic tape)
4 Screen (plastic laminated aluminium tape with drain wire)
5 Sheath (PE black, UV-resistant)

Core identification:
colour code with trace quad in each layer
(TA standard)

Electrical parameters
Conductor diameter
Loop resistance, max.
Insulation resistance, min.
Mutual capacitance, max. at 800 Hz
Capacitance unbalance K1, max. at 800 Hz

(mm)

0.6

0.8

(/km)

130

73,2

(M.km)

10,000

10,000

(nF/km)

55

55

(pF/300 m)

800

800

Capacitance unbalance K9-12, max. at 800 Hz

(pF/300 m)

300

300

Capacitance unbalance E1-E2 at 800 Hz

(pF/300 m)

800

800

Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

F2YA2Y

2 x 2 x 0.6

7.7

13

46

500 T, 1000 T

6 x 2 x 0.6

10.2

36

92

500 T, 1000 T

10 x 2 x 0.6

12

59

123

500 T, 1000 T

20 x 2 x 0.6

13.2

115

198

500 T, 1000 T

30 x 2 x 0.6

15.5

172

279

500 T, 1000 T

40 x 2 x 0.6

17.1

228

352

500 T, 1000 T

50 x 2 x 0.6

19

285

435

500 T, 1000 T

60 x 2 x 0.6

21

342

516

500 T, 1000 T

80 x 2 x 0.6

23

455

671

500 T, 1000 T

100 x 2 x 0.6

24.6

568

796

500 T, 1000 T

Page 105

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

F2YA2Y
Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

F2YA2Y
2 x 2 x 0.8

8.5

22

60

500 T, 1000 T

6 x 2 x 0.8

11

62

131

500 T, 1000 T

10 x 2 x 0.8

14

103

187

500 T, 1000 T

20 x 2 x 0.8

16.5

203

322

500 T, 1000 T

30 x 2 x 0.8

18

304

433

500 T, 1000 T

40 x 2 x 0.8

22

404

566

500 T, 1000 T

50 x 2 x 0.8

26

505

684

500 T, 1000 T

60 x 2 x 0.8

28

606

804

500 T, 1000 T

80 x 2 x 0.8

31

807

1,056

500 T, 1000 T

100 x 2 x 0.8

34

1,008

1,312

500 T, 1000 T

Subject to technical changes.

Page 106

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

F2YC2Y
Underground cable, screened
Standard: adapted to Telecom Austria-Standard
Usage:
Underground cable for use in telecommunications installations
and related installations. Suitable for installation underground,
in water, cable ducts etc.

Rated voltage:

max. 200 Veff

Test voltage:

core/core 500 Veff


core/screen 2000 Veff

Temperature range:
laying temperature:
min. 20 C
operating temperature: in motion 20 C to +50 C
fixed 20 C to +70 C
5

Bending radius (min.): 10 x of cable

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PE), cores pair stranded, pairs stranded in layers
3 Inner covering (plastic tape)
4 Screen (copper tape)
5 Sheath (PE black, UV-resistant)

Core identification:
colour code with trace quad in each layer
(TA standard)

Electrical parameters
Conductor diameter

(mm)

Loop resistance, max.


Insulation resistance, min.
Mutual capacitance, max. at 800 Hz

0.6

0.8

(/km)

130

73.2

(M.km)

10,000

10,000

(nF/km)

55

55

Capacitance unbalance K1, max. at 800 Hz

(pF/300 m)

800

800

Capacitance unbalance K9-12, max. at 800 Hz

(pF/300 m)

300

300

Capacitance unbalance E -E at 800 Hz

(pF/300 m)

800

800

Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

2 x 2 x 0.6

7.0

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

32.0

52

500 T, 1000 T

F2YC2Y

6 x 2 x 0.6

10.2

70.0

112

500 T, 1000 T

10 x 2 x 0.6

13.0

97.0

147

500 T, 1000 T

20 x 2 x 0.6

15.0

173.0

243

500 T, 1000 T

30 x 2 x 0.6

16.5

242.0

322

500 T, 1000 T

40 x 2 x 0.6

17.7

305.0

402

500 T, 1000 T

50 x 2 x 0.6

20.0

370.5

484

500 T, 1000 T

60 x 2 x 0.6

21.0

433.0

556

500 T, 1000 T

80 x 2 x 0.6

23.2

556.0

729

500 T, 1000 T

100 x 2 x 0.6

26.0

682.0

877

500 T, 1000 T

Page 107

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

F2YC2Y
Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

F2YC2Y
2 x 2 x 0.8

8.5

50.0

75

500 T, 1000 T

6 x 2 x 0.8

11.5

104.5

148

500 T, 1000 T

10 x 2 x 0.8

13.4

160.0

221

500 T, 1000 T

20 x 2 x 0.8

17.0

279.0

372

500 T, 1000 T

30 x 2 x 0.8

18.5

392.0

511

500 T, 1000 T

40 x 2 x 0.8

21.4

500.5

633

500 T, 1000 T

50 x 2 x 0.8

24.5

614.5

755

500 T, 1000 T

60 x 2 x 0.8

25.6

725.0

881

500 T, 1000 T

80 x 2 x 0.8

29.4

937.0

1,141

500 T, 1000 T

100 x 2 x 0.8

34.0

1,161.0

1,405

500 T, 1000 T

Subject to technical changes.

Page 108

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

A2Y(L)2YSt III Bd
Underground cable, screened
Standard: VDE 0816
Usage:
The cables are suitable for external telecommunications and data
networks.

5
4
3
2
1
Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PE), cores star quaded and quads stranded in
groups
3 Inner covering (plastic tape)
4 Screen (copolymer laminated aluminium tape which is welded to the
PE sheath)
5 Sheath (PE black, UV-resistant)

Rated voltage:

225 V (peak value)


150 V (peak value) for
0.4 mm

Test voltage:

core/core 500 Veff


( 0.6; 0.8)
core/screen 2000 Veff

Temperature range:
laying temperature:
min. 20 C
operating temperature: 40 C to +70 C
Bending radius (min.): 10 x of cable

Cert
.....
..

.
..

Core identification:

coloured (VDE 0816)

Test certificate:

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Electrical parameters
Conductor diameter

(mm)

0.4

0.6

0.8

(/km)

300

130

73.2

Insulation resistance, min.

(M.km)

5,000

5,000

5,000

Mutual capacitance, (100 % of values)

(nF/km)

50

52

55

Mutual capacitance, (95 % of values)

(nF/km)

48

50

53

Loop resistance, max.

Mutual capacitance, (80 % of values)

(nF/km)

48

50

Capacitance unbalance K1, (100 % of values)

(pF/300 m)

800

800

800

Capacitance unbalance K1, (98 % of values)

(pF/300 m)

400

400

400

Capacitance unbalance K9, (100 % of values)

(pF/300 m)

300

300

300

Capacitance unbalance K9, (98 % of values)

(pF/300 m)

100

100

100

8
Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

A2Y(L)2YBd
6 x 2 x 0.4

9.7

13

85

2000 T

10 x 2 x 0.4

11

26

110

2000 T

20 x 2 x 0.4

13.4

51

163

2000 T

30 x 2 x 0.4

13.7

77

197

2000 T

40 x 2 x 0.4

15.3

103

247

2000 T

50 x 2 x 0.4

16.2

128

292

2000 T

70 x 2 x 0.4

19.1

180

378

2000 T

100 x 2 x 0.4

20.6

257

492

1000 T

150 x 2 x 0.4

24.1

397

707

1000 T

200 x 2 x 0.4

28.7

533

924

2000 T

Page 109

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

A2Y(L)2YSt III Bd
Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

A2Y(L)2YBd
6 x 2 x 0.6

10.8

13

112

2000 T

10 x 2 x 0.6

12.3

35

152

2000 T

20 x 2 x 0.6

14.8

58

241

2000 T

30 x 2 x 0.6

16.5

116

322

2000 T

40 x 2 x 0.6

19.6

172

418

2000 T

50 x 2 x 0.6

21.5

229

501

1000 T

70 x 2 x 0.6

23

286

648

1000 T

100 x 2 x 0.6

25.9

402

889

1000 T

150 x 2 x 0.6

30.3

568

1,297

1000 T

200 x 2 x 0.6

37

850

1,760

1000 T

300 x 2 x 0.6

43.5

1,130

2,530

1000 T

2 x 2 x 0.8

8.8

21

80

2000 T

6 x 2 x 0.8

13.7

62

174

2000 T

10 x 2 x 0.8

15

102

235

2000 T

20 x 2 x 0.8

18.9

204

387

2000 T

30 x 2 x 0.8

21.5

304

533

1000 T

40 x 2 x 0.8

24.8

405

696

1000 T

50 x 2 x 0.8

26.7

506

835

1000 T

70 x 2 x 0.8

29.8

710

1,108

1000 T

100 x 2 x 0.8

34.5

1,008

1,541

1000 T

150 x 2 x 0.8

46.6

1,510

2,382

1000 T

200 x 2 x 0.8

44.3

2,010

2,930

1000 T

Subject to technical changes.

Page 110

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

TCEPKPFLE
Underground cable, screened, longitudinally water-proof
Standard: TP PRAKAB 8/97, SN IEC 708-1
Usage:
These waterproof cables are suitable for external telecommunications
networks which are installed underground, in cable ducts or conduit.

Rated voltage:

250 Veff

Test voltage:

core/core 500 V
core/screen 1000 V

Temperature range:
laying temperature:
min. 10 C to +60 C
operating temperature: 40 C to +70 C
Bending radius (min.): 10 x of cable
5
4
3
2
1
Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (foam skin PE), cores star quaded and quads
stranded in groups, core stranding petrol jelly filled
3 Inner covering (plastic tape)
4 Screen (copolymer laminated aluminium tape which is welded
to the PE sheath)
5 Sheath (PE black, UV-resistant)

Cert
.....
..

.
..

Core identification:

coloured (IEC 708-1)

Test certificate:

EZ Czech Republic

.. .. ...
Sz JZD .
. . ..
.

Electrical parameters
Conductor diameter

(mm)

0.4

0.6

0.8

Loop resistance, max.

(/km)

300

133.2

73.6

Resistance difference.

(%)

Insulation resistance, min. /tested

(M.km)

1,500/10,000

1,500/10,000

1,500/10,000

Mutual capacitance, average, max.

(nF/km)

42

42

42

Mutual capacitance, single value, max.

(nF/km)

49

49

49

Capacitance unbalance K , max.

(pF/500 m)

800

800

800

Specific attenuation at 16 kHz, max.

(dB/km)

6.7

3.8

Specific attenuation at 80 kHz, max.

(dB/km)

10

8
Number of cores x
nominal cross section
(mm2)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

1 x 4 x 0.4

8.6

58

2000 T

3 x 4 x 0.4

10.4

15

86

2000 T

5 x 4 x 0.4

11.0

25

102

2000 T

10 x 4 x 0.4

11.8

50

157

2000 T

15 x 4 x 0.4

14.0

74

207

2000 T

20 x 4 x 0.4

14.5

99

239

2000 T

25 x 4 x 0.4

15.8

124

292

2000 T

35 x 4 x 0.4

17.8

173

389

2000 T

50 x 4 x 0.4

20.1

247

501

1000 T

75 x 4 x 0.4

23.8

370

738

1000 T

TCEPKPFLE

Page 111

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

TCEPKPFLE
Number of cores x
nominal cross section
(mm2)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

TCEPKPFLE
100 x 4 x 0.4

27.0

493

910

1000 T

150 x 4 x 0.4

32.2

739

1,366

1000 T

200 x 4 x 0.4

36.2

986

1,772

500 T

300 x 4 x 0.4

43.3

1,478

2,581

500 T

1 x 4 x 0.6

9.0

11

62

2000 T

3 x 4 x 0.6

11.0

34

19

2000 T

5 x 4 x 0.6

12.5

56

151

2000 T

10 x 4 x 0.6

14.0

111

238

2000 T

15 x 4 x 0.6

16.4

167

348

2000 T

20 x 4 x 0.6

18.9

222

434

2000 T

25 x 4 x 0.6

21.0

278

501

1000 T

35 x 4 x 0.6

23.0

388

684

1000 T

50 x 4 x 0.6

26.5

555

927

1000 T

75 x 4 x 0.6

32.0

832

1,367

1000 T

100 x 4 x 0.6

36.4

1,109

1,885

1000 T

150 x 4 x 0.6

42.9

1,663

2,701

500 T

200 x 4 x 0.6

50.1

2,218

3,580

500 T

1 x 4 x 0.8

9.6

20

83

2000 T

3 x 4 x 0.8

13.0

60

164

2000 T

5 x 4 x 0.8

14.5

99

231

2000 T

10 x 4 x 0.8

18.0

198

378

2000 T

15 x 4 x 0.8

21.5

296

552

2000 T

20 x 4 x 0.8

23.1

395

726

1000 T

25 x 4 x 0.8

27.0

493

806

1000 T

35 x 4 x 0.8

30.0

690

1,135

1000 T

50 x 4 x 0.8

34.3

986

1,658

1000 T

75 x 4 x 0.8

43.0

1,478

2,459

500 T

100 x 4 x 0.8

51.3

1,971

3,487

500 T

Subject to technical changes.

Page 112

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

TK 59 GM
Underground cable, screened, longitudinally water-proof
Standard: SKW-internal standard adapted to JUS
Usage:
Underground cable for use in telecommunications installations and
related installations. Suitable for installation underground, in water,
cable ducts etc.

Rated voltage:

max. 225 Veff

Test voltage:

core/core 500 Veff


core/screen 2000 Veff

Temperature range:
laying temperature:
min. 5 C
operating temperature: 30 C to +50 C
Bending radius (min.): 10 x of cable
5
4
3
2
1
Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (foam skin PE), cores star quaded and quads
stranded in groups (G), core stranding petrol jelly filled (M)
3 Inner covering (plastic tape)
4 Screen (copolymer laminated aluminium tape which is welded
to the PE sheath)
5 Sheath (PE black, UV-resistant)

Core identification:

coloured

Electrical parameters
Conductor diameter

(mm)

0.4

0.6

0.8

(/km)

300

130

73.2

Insulation resistance, min.

(M.km)

5,000

5,000

5,000

Mutual capacitance, at 800 Hz (100 % of values)

(nF/km)

38

42

42

Mutual capacitance, at 800 Hz (95 % of values)

(nF/km)

40

40

Mutual capacitance, at 800 Hz (90 % of values)

(nF/km)

36

Loop resistance, max.

Mutual capacitance, at 800 Hz (80 % of values)

(nF/km)

38

38

Capacitance unbalance K1, at 800 Hz (100 % of values)

(pF/300 m)

800

800

800

Capacitance unbalance K1, at 800 Hz (95 % of values)

(pF/300 m)

400

400

400

Capacitance unbalance K9K12, at 800 Hz (100 % of values)

(pF/300 m)

300

300

300

Capacitance unbalance K9K12, at 800 Hz (95 % of values)

(pF/300 m)

100

100

100

Capacitance unbalance E1E2, at 800 Hz

(pF/300 m)

800

800

800

Number of quads x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

3 x 4 x 0.4

9.6

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

15

86

500 T, 1000 T

TK 59 GM

5 x 4 x 0.4

13

25

140

500 T, 1000 T

10 x 4 x 0.4

15

50

198

500 T, 1000 T

15 x 4 x 0.4

17.5

75

266

500 T, 1000 T

25 x 4 x 0.4

21

124

383

500 T, 1000 T

35 x 4 x 0.4

25

174

511

500 T, 1000 T

50 x 4 x 0.4

27.7

248

667

500 T, 1000 T

Page 113

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

TK 59 GM
Number of quads x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

TK 59 GM
75 x 4 x 0.4

33.8

382

989

500 T, 1000 T

100 x 4 x 0.4

38.1

504

1,270

500 T, 1000 T

150 x 4 x 0.4

42.6

774

1,697

500 T, 1000 T

200 x 4 x 0.4

49.8

1028

2,277

500 T

250 x 4 x 0.4

52.4

1547

2,775

500 T

3 x 4 x 0.6

11.5

35

132

500 T, 1000 T

5 x 4 x 0.6

14

57

195

500 T, 1000 T

10 x 4 x 0.6

17

114

303

500 T, 1000 T

15 x 4 x 0.6

19.5

172

377

500 T, 1000 T

25 x 4 x 0.6

23

287

551

500 T, 1000 T

35 x 2 x 0.6

27

401

763

500 T, 1000 T

50 x 2 x 0.6

31

572

1,020

500 T, 1000 T

75 x 4 x 0.6

37

821

1,502

500 T, 1000 T

100 x 4 x 0.6

41.5

1156

1,933

500 T, 1000 T

150 x 4 x 0.6

50

1741

2,869

500 T

200 x 4 x 0.6

57.5

2313

3,716

500 T

3 x 4 x 0.8

13.3

60

173

500 T, 1000 T

5 x 4 x 0.8

16.4

102

237

500 T, 1000 T

10 x 4 x 0.8

20.4

203

403

500 T, 1000 T

15 x 4 x 0.8

23.7

305

539

500 T, 1000 T

25 x 4 x 0.8

29.1

508

799

500 T, 1000 T

35 x 4 x 0.8

33.9

711

1,085

500 T, 1000 T

50 x 4 x 0.8

39.9

1015

1,476

500 T, 1000 T

75 x 4 x 0.8

47.7

1501

2,206

500 T, 1000 T

100 x 4 x 0.8

54.5

2055

2,884

500 T

Subject to technical changes.

Page 114

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

A2YF(L)2YSt III Bd
Underground cable, screened, longitudinally water-proof
Standard: VDE 0816
Usage:
These cables are suitable for external telecommunications networks
which are installed underground, in cable ducts or conduit.

5
4
3
2
1
Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (PE), cores star quaded and quads stranded in
groups, core stranding petrol jelly filled
3 Inner covering (plastic tape)
4 Screen (copolymer laminated aluminium tape which is welded
to the PE sheath)
5 Sheath (PE black, UV-resistant)

Rated voltage:

225 V (peak value)


150 V (peak value) for
0.4 mm

Test voltage:

core/core 500 Veff


( 0.6; 0.8)
core/screen 2000 Veff

Temperature range:
laying temperature:
min. 20 C
operating temperature: 40 C to +70 C
Bending radius (min.): 10 x of cable

Cert
.....
..

.
..

Core identification:

coloured (VDE 0816)

Test certificate:

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Electrical parameters
Conductor diameter

(mm)

Loop resistance, max.

0.4

0.6

0.8

(/km)

300

130

73.2

Insulation resistance, min.

(M.km)

1,500

1,500

1,500

Mutual capacitance, (100 % of values)

(nF/km)

50

52

55

Mutual capacitance, (95 % of values)

(nF/km)

48

50

53

Mutual capacitance, (80 % of values)

(nF/km)

48

50

Capacitance unbalance K1, (100 % of values)

(pF/300 m)

800

800

800

Capacitance unbalance K1, (98 % of values)

(pF/300 m)

400

400

400

Capacitance unbalance K9, (100 % of values)

(pF/300 m)

300

300

300

Capacitance unbalance K9, (98 % of values)

(pF/300 m)

100

100

100

8
Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

10 x 2 x 0.4

11.5

20 x 2 x 0.4
30 x 2 x 0.4

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

26

130

2000 T

14.2

51

203

2000 T

14.5

77

232

2000 T

40 x 2 x 0.4

16.3

103

297

2000 T

50 x 2 x 0.4

17.3

128

350

2000 T

70 x 2 x 0.4

20.5

180

474

1000 T

100 x 2 x 0.4

22.1

257

596

1000 T

150 x 2 x 0.4

25.9

397

850

1000 T

200 x 2 x 0.4

30.9

533

1,166

1000 T

A2Y(L)2YBd

Page 115

- >> TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

A2YF(L)2YSt III Bd
Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

A2Y(L)2YBd
2 x 2 x 0.6

13

78

2000 T

6 x 2 x 0.6

12

35

140

2000 T

10 x 2 x 0.6

13.5

58

190

2000 T

20 x 2 x 0.6

16.5

116

310

2000 T

30 x 2 x 0.6

19.5

172

430

2000 T

40 x 2 x 0.6

21.5

229

545

1000 T

50 x 2 x 0.6

23.5

286

660

1000 T

70 x 2 x 0.6

27

402

895

1000 T

100 x 2 x 0.6

31.5

568

1,225

1000 T

150 x 2 x 0.6

36.3

850

1,727

1000 T

200 x 2 x 0.6

40.3

1130

2,205

1000 T

2 x 2 x 0.8

21

102

2000 T

6 x 2 x 0.8

13.5

62

230

2000 T

10 x 2 x 0.8

15.5

102

330

2000 T

20 x 2 x 0.8

22

204

560

1000 T

30 x 2x 0.8

25

304

740

1000 T

40 x 2 x 0.8

27

405

900

1000 T

50 x 2 x 0.8

30

506

1,100

1000 T

70 x 2 x 0.8

33

710

1,420

1000 T

100 x 2 x 0.8

41

1008

2,000

1000 T

150 x 2 x 0.8

52.6

1510

3,279

500 T

200 x 2 x 0.8

60.4

2010

4,357

500 T

Subject to technical changes.

Page 116

SKW | PRAKAB | Products

- >> HALOGEN-FREE BUILDING WIRES

H05ZU / H05ZK
Insulated wire
Standard: VE/NORM E 8240-9
Usage:
Suitable for protected installation in equipment and in and on
lights. Also for installation in conduit and on and under plaster, but
only for signalling installations. Since they are free from halogens
and exhibit enhanced fire performance, these cables are used in
those applications where in the event of fire, the negative effects
on concentrations of people and valuable material goods must be
minimised.

Rated voltage:

300/500 V

Test voltage:

2000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
20 C to +80 C
max. +90 C
max. +250 C/5 s

Bending radius (min.): 4 x of wire


2

Core identification:
black (sw), blue (bl), brown (br), green/yellow
(gnge), grey (gr)

Construction:
1 Copper conductor, solid wire (-U) resp. fine wire (-K)
2 Core insulation (halogen-free polymer compound, cross-linked)

Fire properties:
flame retardant

(EN 50265-2-1,
IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267, IEC 60754-2)
minimum smoke emission
(EN 50268, IEC 61034)
Test certificate:

Cert
.....
..

Nominal
cross section
(mm2)

Colour of core

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

.
..

VE Austria

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

H05ZU
0.5

sw, br, bl

36.0

2.0

5.0

100 R

0.75

sw, br, bl

24.5

2.2

7.5

12

100 R

sw, br, bl

18.1

2.4

10.0

14

100 R

0.5

gnge

36.0

2.0

5.0

100 R

0.75

gnge

24.5

2.2

7.5

12

100 R

gnge

18.1

2.4

10.0

14

100 R

H07ZK

0.5

sw, br, bl

39.0

2.2

5.0

100 R

0.75

sw, br, bl

26.0

2.4

7.5

12

100 R

sw, br, bl

19.5

2.6

10.0

14

100 R

0.5

gnge, gr

39.0

2.2

5.0

100 R

0.75

gnge, gr

26.0

2.4

7.5

12

100 R

gnge, gr

19.5

2.6

10.0

14

100 R

Subject to technical changes.

Page 117

SKW | PRAKAB | Products

- >> HALOGEN-FREE BUILDING WIRES

H07ZU / H07ZR / H07ZK


Insulated wire
Standard: VE/NORM E 8240-9
Usage:
For fixed installation in conduit on or under plaster. Suitable for
protected fixed installation in and on lighting installations or
control equipment for ac voltages up to 1000 V or dc voltages up
to 750 V towards earth. Since they are free from halogens and
exhibit enhanced fire performance, these cables are used in those
applications where in the event of fire, the negative effects on
concentrations of people and valuable material goods must be
minimised.

Rated voltage:

450/750 V

Test voltage:

2500 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
20 C to +80 C
max. +90 C
max. +250 C/5 s

Bending radius (min.): 4 x of wire

Core identification:
black (sw), blue (bl), brown (br), green/yellow
(gnge), grey (gr)

Construction:
1 Copper conductor, solid wire (-U), stranded wire (-R) or fine wire (-K)
2 Core insulation (halogen-free polymer compound, cross-linked)

Fire properties:
flame retardant

(EN 50265-2-1,
IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267, IEC 60754-2)
minimum smoke emission
(EN 50268, IEC 61034)
Test certificate:

Cert
.....
..

Nominal
cross section
(mm2)

Colour of core

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

.
..

VE Austria

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

H07ZU
1.5

sw, br, bl

12.1

3.0

15

20

100 R

2.5

sw, br, bl

7.41

3.5

25

30

100 R

sw, br, bl

4.61

4.0

40

45

100 R

1.5

gnge

12.1

3.0

15

20

100 R

2.5

gnge

7.41

3.5

25

30

100 R

gnge

4.61

4.0

40

45

100 R

H07ZR
6

sw, br, bl

3.0800

5.0

60

65

100 R

10

sw, bl, br

1.8300

6.5

100

110

100 R

16

sw, bl, br

1.1500

7.5

160

175

100 R

25

sw

0.7270

9.0

250

275

500 T, 1000 T

35

sw

0.5240

10.0

350

365

500 T, 1000 T

50

sw

0.3870

12.0

500

490

500 T, 1000 T

70

sw

0.2680

14.0

700

700

500 T, 1000 T

95

sw

0.1930

16.5

950

920

500 T, 1000 T

120

sw

0.1530

18.5

1,200

1,150

500 T, 1000 T

150

sw

0.1240

20.5

1,500

1,400

500 T, 1000 T

185

sw

0.0991

22.5

1,850

1,760

500 T, 1000 T

Page 118

SKW | PRAKAB | Products

- >> HALOGEN-FREE BUILDING WIRES

H07ZU / H07ZR / H07ZK


Nominal
cross section
(mm2)

Colour of core

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

H07ZR
240

sw

0.0754

25.5

2,400

2,300

500 T, 1000 T

gnge, special colours

3.0800

5.0

60

65

100 R

10

gnge, special colours

1.8300

6.5

100

110

100 R

16

gnge, special colours

1.1500

7.5

160

175

100 R

25

gnge, special colours

0.7270

9.0

250

275

500 T, 1000 T

35

gnge, special colours

0.5240

10.0

350

365

500 T, 1000 T

50

gnge, special colours

0.3870

12.0

500

490

500 T, 1000 T

70

gnge, special colours

0.2680

14.0

700

700

500 T, 1000 T

95

gnge, special colours

0.1930

16.5

950

920

500 T, 1000 T

120

gnge, special colours

0.1530

18.5

1,200

1,150

500 T, 1000 T

150

gnge, special colours

0.1240

20.5

1,500

1,400

500 T, 1000 T

185

gnge, special colours

0.0991

22.5

1,850

1,760

500 T, 1000 T

240

gnge, special colours

0.0754

25.5

2,400

2,300

500 T, 1000 T

H07ZK
1.5

sw, br, bl

13.300

2.9

15

20

100 R

2.5

sw, br, bl

7.980

3.6

25

31

100 R

sw, br, bl

4.950

4.4

40

50

100 R

sw, br, bl

3.300

4.7

60

69

100 R

10

sw, br, bl

1.910

6.0

100

110

100 R

16

sw, br, bl

1.210

7.5

160

170

100 R

25

sw, br, bl

0.780

9.5

250

255

500 T, 1000 T

35

sw, br, bl

0.554

11.0

350

345

500 T, 1000 T

50

sw, br, bl

0.386

13.0

500

490

500 T, 1000 T

70

sw, br, bl

0.272

15.0

700

700

500 T, 1000 T

95

sw

0.206

17.0

950

930

500 T, 1000 T

120

sw

0.161

18.5

1,200

1,150

500 T, 1000 T

150

sw

0.129

21.0

1,500

1,400

500 T, 1000 T

185

sw

0.106

23.0

1,850

1,840

500 T, 1000 T

240

sw

0.080

27.0

2,400

2,400

500 T, 1000 T

1.5

gnge, gr

13.300

2.9

15

20

100 R

2.5

gnge, gr

7.980

3.6

25

31

100 R

gnge, gr

4.950

4.4

40

50

100 R

gnge, gr

3.300

4.7

60

69

100 R

10

gnge, gr

1.910

6.0

100

110

100 R

16

gnge, gr

1.210

7.5

160

170

100 R

25

gnge, gr

0.780

9.5

250

255

500 T, 1000 T

35

gnge, gr

0.554

11.0

350

345

500 T, 1000 T

50

gnge, gr

0.386

13.0

500

490

500 T, 1000 T

70

gnge, gr

0.272

15.0

700

700

500 T, 1000 T

Subject to technical changes.

Page 119

- >> HALOGEN-FREE BUILDING WIRES

SKW | PRAKAB | Products

NHXMH
Installation cable
Standard: DIN VDE 0250-214
Usage:
As installation cable for fixed installation over, on, in and under
plaster, in dry, damp and wet premises and in masonry and also in
the open air but not for direct burial. Since they are free from halogens and exhibit enhanced fire performance, these cables are
used in those applications where in the event of fire, the negative
effects on concentrations of people and valuable material goods
must be minimised.

Rated voltage:

300/500 V

Test voltage:

2000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5 C
fixed 40 C to +70 C
max. +70 C
max. +160 C/5 s

Bending radius (min.): 4 x of cable


Core identification:
4

Fire properties:
halogen-free, no corrosive combustion gases
(EN 50267-2-2,
IEC 60754-2)
reduced fire propagation
(EN 50266-2-4,
IEC 60332-3 Cat. C)
minimum smoke emission
(EN 50268-2,
IEC 61034)

Construction:
1 Copper conductor, round solid (RE) resp. round stranded (RM)
2 Core insulation (XLPE)
3 Inner covering (halogen-free polymer compound)
4 Sheath (halogen-free polyolefin compound, grey)

Test certificate:

Cert
.....
..

Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

coloured (HD 308 S2)

.
..

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

NHXMH
2 x 1.5 RE

12.100

9.1

30

124

500 T, 1000 T

3 x 1.5 RE

12.100

9.5

45

139

500 T, 1000 T

4 x 1.5 RE

12.100

10.1

60

161

500 T, 1000 T

5 x 1.5 RE

12.100

10.8

75

186

500 T, 1000 T

2 x 2.5 RE

7.410

9.9

50

157

500 T, 1000 T

3 x 2.5 RE

7.410

10.3

75

180

500 T, 1000 T

4 x 2.5 RE

7.410

11.1

100

214

500 T, 1000 T

5 x 2.5 RE

7.410

11.9

125

249

500 T, 1000 T

3 x 4 RE

4.610

11.8

120

251

500 T, 1000 T

4 x 4 RE

4.610

13.1

160

312

500 T, 1000 T

5 x 4 RE

4.610

14.5

200

381

500 T, 1000 T

3 x 6 RE

3.080

13.3

173

341

500 T, 1000 T

4 x 6 RE

3.080

14.7

240

427

500 T, 1000 T

5 x 6 RE

3.080

15.9

300

490

500 T, 1000 T

3 x 10 RE

1.830

15.8

300

519

500 T, 1000 T

Page 120

- >> HALOGEN-FREE BUILDING WIRES

SKW | PRAKAB | Products

NHXMH
Number of cores x
nominal cross
section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

NHXMH
4 x 10 RE

1.830

17.1

400

623

500 T, 1000 T

5 x 10 RE

1.830

18.2

500

734

500 T, 1000 T

4 x 16 RM

1.150

20.3

640

946

500 T, 1000 T

5 x 16 RM

1.150

22.5

800

1,118

500 T, 1000 T

4 x 25 RM

0.727

25.1

1,000

1,439

500 T, 1000 T

4 x 35 RM

0.524

28.5

1,400

1,880

500 T, 1000 T

7 x 1.5 RE

12.100

11.6

105

226

500 T, 1000 T

10 x 1.5 RE

12.100

14.0

150

325

500 T, 1000 T

12 x 1.5 RE

12.100

15.0

180

361

500 T, 1000 T

7 x 2.5 RE

7.410

14.0

175

339

500 T, 1000 T

Subject to technical changes.

Page 121

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHR, 1CXKHR
Energy cable
Standard: TP PRAKAB 02/99 5. edition

Rated voltage:

0.6/1 kV

Usage:
The cables are specified for stationary distribution of electrical
energy in dry and damp premises. Suitable for hotels, hospitals,
underground railways, airports etc to protect people and technical
building equipment in the event of fire where there is no requirement
for maintaining the function of the cable in the event of fire.

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:
Bending radius (min.):

Core identification:

4
3
2
1
Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (halogen-free polymer /1-CHKH-R, XLPE/1-CXKH-R)
3 Inner covering (halogen-free tape)
4 Sheath (halogen-free polymer compound, orange)

Number of cores x
nominal
cross section
(mm2)

Max. conductor Current rating in


resistance
the air1)
(/km)
(A)

min. 5 C
30 C up to +90 C
max. +90 C
max. +250 C/5 s
6 x for < 20 mm
12 x for 20 to 40 mm
15 x for > 40 mm
coloured (HD 308 S2)

Fire properties:
flame retardant
(EN 50265-2-1, IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2, IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A,
EN 50266-2-2)
minimum smoke emission (EN 50268-2, IEC 61034)
Test certificate:

Cert
.....
..

.
..

EZ Czech Republic,
GOST Russia
(only 1CHKHR)

.. .. ...
Sz JZD .
. . ..
.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHR, 1CXKHR
2 x 1.5 RE

12.5310

29

9.8

29

130

1000 T

3 x 1.5 RE

12.5310

24

10.2

44

145

1000 T

4 x 1.5 RE

12.5310

24

11.0

59

170

1000 T

5 x 1.5 RE

12.5310

24

11.8

74

200

1000 T

7 x 1.5 RE

12.5310

14

12.7

103

240

1000 T

12 x 1.5 RE

12.5310

12

16.1

176

360

500 T

19 x 1.5 RE

12.5310

11

18.5

279

505

500 T

24 x 1.5 RE

12.5310

10

21.5

353

620

500 T

37 x 1.5 RE

12.5310

24.6

544

885

500 T

48 x 1.5 RE

12.5310

27.9

706

1,110

500 T

2 x 2.5 RE

7.5200

38

10.6

49

165

1000 T

3 x 2.5 RE

7.5200

32

11.1

74

190

1000 T

4 x 2.5 RE

7.5200

32

11.9

98

225

1000 T

5 x 2.5 RE

7.5200

32

12.9

123

265

1000 T

7 x 2.5 RE

7.5200

20

13.9

172

320

1000 T

12 x 2.5 RE

7.5200

17

17.7

294

495

500 T

19 x 2.5 RE

7.5200

16

20.5

466

710

500 T

24 x 2.5 RE

7.5200

13

24.1

588

890

500 T

37 x 2.5 RE

7.5200

12

27.4

907

1,270

500 T

Page 122

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHR, 1CXKHR
Number of cores x
nominal
cross section
(mm2)

Max. conductor Current rating in


resistance
the air1)
(/km)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHR, 1CXKHR
48 x 2.5 RE

7.5200

11

31.6

1,176

1,640

500 T

2 x 4 RE

4.7000

51

11.6

78

215

1000 T

3 x 4 RE

4.7000

42

12.2

118

255

1000 T

4 x 4 RE

4.7000

42

13.2

157

305

1000 T

5 x 4 RE

4.7000

42

14.3

196

360

1000 T

7 x 4 RE

4.7000

28

15.4

274

455

1000 T

12 x 4 RE

4.7000

23

19.9

470

710

500 T

1 x 6 RE

3.1330

725

7.3

59

105

1000 T

2 x 6 RE

3.1330

64

12.6

118

275

1000 T

3 x 6 RE

3.1330

53

13.3

176

330

1000 T

4 x 6 RE

3.1330

53

14.4

235

400

1000 T

5 x 6 RE

3.1330

53

15.6

294

480

1000 T

1 x 10 RE

1.8800

99

8.1

98

145

1000 T

2 x 10 RE

1.8800

86

14.1

196

375

1000 T

3 x 10 RE

1.8800

74

14.9

294

465

1000 T

4 x 10 RE

1.8800

74

16.2

392

575

500 T

5 x 10 RE

1.8800

74

17.7

490

690

500 T

1 x 16 RE

1.1750

131

9.0

157

205

1000 T

2 x 16 RE

1.1750

110

15.9

314

520

500 T

3 x 16 RE

1.1750

98

16.9

470

660

500 T

4 x 16 RE

1.1750

98

18.3

627

820

500 T

5 x 16 RE

1.1750

98

20.1

882

995

500 T

1 x 25 RM

0.7520

177

10.8

245

300

1000 T

3 x 25 RE

0.7520

133

19.9

735

955

500 T

3 x 25 RM

0.7520

133

20.8

735

985

500 T

3 x 25 + 16 RE/RE

0.7520/1.1750

133

21.8

892

1,100

500 T

3 x 25 + 16 RM/RE

0.7520/1.1750

133

22.7

892

1,125

500 T

4 x 25 RE

0.7520

133

21.8

980

1,195

500 T

4 x 25 RM

0.7520

133

22.7

980

1,235

500 T

5 x 25 RM

0.7520

133

25.2

1,225

1,520

500 T

1 x 35 RM

0.5370

217

11.8

343

390

1000 T

3 x 35 RM

0.5370

162

22.9

1,029

1,300

500 T

3 x 35 + 16 SM/RE

0.5370/1.1750

162

24.2

1,186

1,350

500 T

3 x 35 + 25 RM/RM

0.5370/0.7520

162

25.3

1,274

1,530

500 T

3 x 35 + 25 SM/RM

0.5370/0.7520

162

24.2

1,274

1,425

500 T

4 x 35 RM

0.5370

162

25.3

1,372

1,650

500 T

4 x 35 SM

0.5370

162

24.2

1,372

1,510

500 T

5 x 35 RM

0.5370

162

27.9

1,715

2,020

500 T

1 x 50 RM

0.3870

265

13.7

490

555

1000 T

3 x 50 RM

0.3870

197

27.2

1,470

1,685

500 T

Page 123

10

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHR, 1CXKHR
Number of cores x
nominal
cross section
(mm2)

Max. conductor Current rating in


resistance
the air1)
(/km)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHR, 1CXKHR
3 x 50 + 25 SM/RM

0.3870/0.7520

197

27.2

1,715

1,855

500 T

3 x 50 + 35 SM/RM

0.3870/0.5370

197

27.2

1,813

1,940

500 T

4 x 50 SM

0.3870

197

27.2

1,960

2,070

500 T

5 x 50 RM

0.3870

197

33.3

2,450

2,740

500 T

1 x 70 RM

0.2680

336

15.6

686

740

1000 T

3 x 70 RM

0.2680

250

31.7

2,058

2,275

500 T

3 x 70 + 35 SM/RM

0.2680/0.5370

250

31.5

2,401

2,560

500 T

3 x 70 + 50 SM/RM

0.2680/0.3870

250

31.5

2,548

2,705

500 T

4 x 70 RM

0.2680

250

34.5

2,744

2,940

500 T

4 x 70 SM

0.2680

250

31.5

2,744

2,865

500 T

5 x 70 RM

0.2680

250

38.6

3,430

3,690

500 T

1 x 95 RM

0.1980

415

17.3

931

975

1000 T

3 x 95 + 50 SM/RM

0.1980/0.3870

308

35.4

3,283

3,480

500 T

4 x 95 RM

0.1980

308

39.1

3,724

3,960

500 T

4 x 95 SM

0.1980

308

35.4

3,724

3,880

500 T

5 x 95 RM

0.1980

308

43.6

4,655

4,980

500 T

1 x 120 RM

0.1570

485

19.4

1,176

1,225

1000 T

3 x 120 + 50 SM/RM

0.1570/0.3870

359

39.1

4,018

4,135

500 T

3 x 120 + 70 SM/RM

0.1570/0.2680

359

39.1

4,214

4,305

500 T

4 x 120 SM

0.1570

359

39.1

4,704

4,735

500 T

5 x 120 RM

0.1570

359

48.6

5,880

6,120

500 T

1 x 150 RM

0.1240

557

21.0

1,470

1,505

500 T

3 x 150 + 70 SM/RM

0.1240/0.2680

412

43.7

5,096

5,230

500 T

4 x 150 SM

0.1240

412

43.7

5,880

5,935

300 T

5 x 150 RM

0.1240

412

53.3

7,350

7,635

300 T

1 x 185 RM

0.1020

646

23.4

1,813

1,865

500 T

3 x 185 + 95 SM/RM

0.1020/0.1980

475

48.7

6,370

6,560

300 T

4 x 185 SM

0.1020

475

48.7

7,252

7,355

300 T

5 x 185 RM

0.1020

475

60.0

9,065

9,510

300 T

1 x 240 RM

0.0783

774

26.0

2,352

2,410

500 T

3 x 240 + 120 SM/RM

0.0783/0.1570

564

54.9

8,232

8,320

300 T

4 x 240 SM

0.0783

564

54.9

9,408

9,380

300 T

5 x 240 RM

0.0783

564

66.3

11,760

12,230

300 T

1 x 300 RM

0.0601

901

30.6

2,940

3,040

500 T

1 x 500 RM

0.0366

1252

38.5

4,900

5,164

300 T

1 x 630 RM

0.0283

1486

40.7

6,174

6,360

300 T

1) basic rated current acc. to TP PRAKAB 02/99 5. edition


Subject to technical changes.

Page 124

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CSKHV180
Energy cable with insulation integrity FE180
Standard: TP PRAKAB 01/05

Rated voltage:

0.6/1 kV

Usage:
The cables are specified for stationary distribution of electrical
energy in dry and damp premises. Suitable for hotels, hospitals,
underground railways, airports etc to protect people and technical
building equipment in the event of fire where there is no requirement
for maintaining the function of the cable in the event of fire.

Test voltage:

4 kV/50 Hz

Temperature range:
laying temperature:
min. 5 C
operating temperature: 30 C up to +90 C
shor-circuit
temperature:
max. +250 C/5 s
Bending radius (min.):

Core identification:
3

Fire properties:
flame retardant
(EN 50265-2-1, IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2, IEC 60754-2)
reduced fire propagation
(IEC 60332-3 Cat. A, EN 50266-2-2,
DIN VDE 0472-804)
minimum smoke emission
(EN 50268-2, IEC 61034)
insulation integrity FE180
(IEC 60331, DIN VDE 0472-814)

Construction:
1 Copper conductor, round solid (RE)
2 Insulation (silicone rubber)
3 Sheath (halogen-free polymer compound, brown)

Test certificate:

Cert
.....
..

Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating
in the air1)
(A)

6 x for < 20 mm
12 x for 20 to 40 mm
15 x for > 40 mm
coloured (HD 308 S2)

Outer
diameter
(mm) ca.

.
..

EZ Czech Republic

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CSKHV180
2 x 1.5 RE

12.531

29

9.8

29

130

1000 T

3 x 1.5 RE

12.531

24

10.2

44

145

1000 T

4 x 1.5 RE

12.531

24

11

59

170

1000 T

5 x 1.5 RE

12.531

24

11.8

74

200

1000 T

7 x 1.5 RE

12.531

14

12.7

103

240

1000 T

12 x 1.5 RE

12.531

12

16.1

176

360

500 T

19 x 1.5 RE

12.531

11

18.5

279

505

500 T

24 x 1.5 RE

12.531

10

21.5

353

620

500 T

37 x 1.5 RE

12.531

24.6

544

885

500 T

48 x 1.5 RE

12.531

27.9

706

1,110

500 T

2 x 2.5 RE

7.520

38

10.6

49

165

1000 T

3 x 2.5 RE

7.520

32

11.1

74

190

1000 T

4 x 2.5 RE

7.520

32

11.9

98

225

1000 T

5 x 2.5 RE

7.520

32

12.9

123

265

1000 T

7 x 2.5 RE

7.520

20

13.9

172

320

1000 T

12 x 2.5 RE

7.520

17

17.7

294

495

500 T

19 x 2.5 RE

7.520

16

20.5

466

710

500 T

Page 125

10

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CSKHV180
Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CSKHV180
24 x 2.5 RE

7.520

13

24.1

588

890

500 T

37 x 2.5 RE

7.520

12

27.4

907

1,270

500 T

48 x 2.5 RE

7.520

11

31.6

1176

1,640

500 T

2 x 4 RE

4.700

51

11.6

78

215

1000 T

3 x 4 RE

4.700

42

12.2

118

255

1000 T

4 x 4 RE

4.700

42

13.2

157

305

1000 T

5 x 4 RE

4.700

42

14.3

196

360

1000 T

7 x 4 RE

4.700

28

15.4

274

455

1000 T

12 x 4 RE

4.700

23

19.9

470

710

500 T

1 x 6 RE

3.133

725

7.3

59

105

1000 T

2 x 6 RE

3.133

64

12.6

118

275

1000 T

3 x 6 RE

3.133

53

13.3

176

330

1000 T

4 x 6 RE

3.133

53

14.4

235

400

1000 T

5 x 6 RE

3.133

53

15.6

294

480

1000 T

1 x 10 RE

1.880

99

8.1

98

145

1000 T

2 x 10 RE

1.880

86

14.1

196

375

1000 T

3 x 10 RE

1.880

74

14.9

294

465

1000 T

4 x 10 RE

1.880

74

16.2

392

575

500 T

5 x 10 RE

1.880

74

17.7

490

690

500 T

1 x 16 RE

1.175

131

157

205

1000 T

2 x 16 RE

1.175

110

15.9

314

520

500 T

3 x 16 RE

1.175

98

16.9

470

660

500 T

4 x 16 RE

1.175

98

18.3

627

820

500 T

5 x 16 RE

1.175

98

20.1

882

995

500 T

1) basic rated current acc. to TP PRAKAB 01/05


Subject to technical changes.

Page 126

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CSKHV180/E30
Energy cable with insulation integrity FE180
and functional integrity E30
Standard: TP PRAKAB 01/05
Usage:
The cables are specified for stationary distribution of electrical
energy in dry and damp premises. Suitable for hotels, hospitals,
underground railways, airports etc to protect people and technical
building equipment in the event of fire where there is no requirement
for maintaining the function of the cable in the event of fire.

Rated voltage:

0.6/1 kV

Test voltage:

4 kV/50 Hz

Temperature range:
laying temperature:
min. 5 C
operating temperature: 30 C up to +90 C
shor-circuit
temperature:
max. +250 C/5 s
Bending radius (min.):

Core identification:

Fire properties:
flame retardant
(EN 50265-2-1, IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2, IEC 60754-2)
reduced fire propagation
(IEC 60332-3 Cat. A, EN 50266-2-2,
DIN VDE 0472-804)
minimum smoke emission
(EN 50268-2, IEC 61034)
insulation integrity FE180
(IEC 60331, DIN VDE 0472-814)
functional integrity E30 (DIN VDE 4102-12)

Construction:
1 Copper conductor, round solid (RE)
2 Insulation (silicone rubber)
3 Sheath (halogen-free polymer compound, brown)

Test certificate:

Cert
.....
..

Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating
in the air1)
(A)

2 x 1.5 RE

12.531

29

3 x 1.5 RE

12.531

24

4 x 1.5 RE

12.531

5 x 1.5 RE

12.531

6 x for < 20 mm
12 x for 20 to 40 mm
15 x for > 40 mm
coloured (HD 308 S2)

Outer
diameter
(mm) ca.

.
..

EZ Czech Republic

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

9.8

29

130

1000 T

10.2

44

145

1000 T

24

11

59

170

1000 T

24

11.8

74

200

1000 T

1CSKHV180/E30

7 x 1.5 RE

12.531

14

12.7

103

240

1000 T

12 x 1.5 RE

12.531

12

16.1

176

360

500 T

19 x 1.5 RE

12.531

11

18.5

279

505

500 T

24 x 1.5 RE

12.531

10

21.5

353

620

500 T

37 x 1.5 RE

12.531

24.6

544

885

500 T

48 x 1.5 RE

12.531

27.9

706

1,110

500 T

2 x 2.5 RE

7.520

38

10.6

49

165

1000 T

3 x 2.5 RE

7.520

32

11.1

74

190

1000 T

4 x 2.5 RE

7.520

32

11.9

98

225

1000 T

5 x 2.5 RE

7.520

32

12.9

123

265

1000 T

7 x 2.5 RE

7.520

20

13.9

172

320

1000 T

12 x 2.5 RE

7.520

17

17.7

294

495

500 T

19 x 2.5 RE

7.520

16

20.5

466

710

500 T

Page 127

10

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CSKHV180/E30
Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CSKHV180/E30
24 x 2.5 RE

7.520

13

24.1

588

890

500 T

37 x 2.5 RE

7.520

12

27.4

907

1,270

500 T

48 x 2.5 RE

7.520

11

31.6

1,176

1,640

500 T

2 x 4 RE

4.700

51

11.6

78

215

1000 T

3 x 4 RE

4.700

42

12.2

118

255

1000 T

4 x 4 RE

4.700

42

13.2

157

305

1000 T

5 x 4 RE

4.700

42

14.3

196

360

1000 T

7 x 4 RE

4.700

28

15.4

274

455

1000 T

12 x 4 RE

4.700

23

19.9

470

710

500 T

1 x 6 RE

3.133

725

7.3

59

105

1000 T

2 x 6 RE

3.133

64

12.6

118

275

1000 T

3 x 6 RE

3.133

53

13.3

176

330

1000 T

4 x 6 RE

3.133

53

14.4

235

400

1000 T

5 x 6 RE

3.133

53

15.6

294

480

1000 T

1 x 10 RE

1.880

99

8.1

98

145

1000 T

2 x 10 RE

1.880

86

14.1

196

375

1000 T

3 x 10 RE

1.880

74

14.9

294

465

1000 T

4 x 10 RE

1.880

74

16.2

392

575

500 T

5 x 10 RE

1.880

74

17.7

490

690

500 T

1 x 16 RE

1.175

131

157

205

1000 T

2 x 16 RE

1.175

110

15.9

314

520

500 T

3 x 16 RE

1.175

98

16.9

470

660

500 T

4 x 16 RE

1.175

98

18.3

627

820

500 T

5 x 16 RE

1.175

98

20.1

882

995

500 T

1) basic rated current acc. to TP PRAKAB 01/05


Subject to technical changes.

Page 128

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHV180, 1CXKHV180
Power cables with insulation integrity FE180

Rated voltage:

0.6/1 kV

Standard: TP PRAKAB 02/99 5. edition

Test voltage:

4000 Veff

Usage:
The cables are specified for stationary distribution of electrical
energy in dry and damp premises. Suitable for hotels, hospitals,
underground railways, airports etc to protect people and technical
building equipment in the event of fire where there is a requirement
to maintain the function of the cable in the event of fire.

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:
Bending radius (min.):

Core identification:

3 2

Max. conductor
resistance
(/km)

Current rating
in the air1)
(A)

max. +250 C/5 s


6 x for < 20 mm
12 x for 20 to 40 mm
15 x for > 40 mm
coloured (HD 308 S2)

Fire properties:
flame retardant
(EN 50265-2-1, IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2, IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A,
EN 50266-2-2)
minimum smoke emission
(EN 50268-2, IEC 61034)
insulation integrity FE180
(IEC 60331, DIN VDE 0472-814)

Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Flame protection (mica tape)
3 Core insulation (halogen-free polymer /1-CHKH-V180,
XLPE/1-CXKH-V180)
4 Inner covering (halogen-free tape)
5 Sheath (halogen-free polymer compound, brown)

Number of cores x
nominal
cross section
(mm2)

min. 5 C
fixed 30 C up to +90 C
max. +90 C

Test certificate:

Cert
.....
..

.
..

EZ Czech Republic,
GOST Russia
(only 1CHKHV180)

.. .. ...
Sz JZD .
. . ..
.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHV180, 1CXKHV180
2 x 1.5 RE

12.5310

29

9.8

29

130

1000 T

3 x 1.5 RE

12.5310

24

10.2

44

145

1000 T

4 x 1.5 RE

12.5310

24

11.0

59

170

1000 T

5 x 1.5 RE

12.5310

24

11.8

74

200

1000 T

7 x 1.5 RE

12.5310

14

12.7

103

240

1000 T

12 x 1.5 RE

12.5310

12

16.1

176

360

500 T

19 x 1.5 RE

12.5310

11

18.5

279

505

500 T

24 x 1.5 RE

12.5310

10

21.5

353

620

500 T

37 x 1.5 RE

12.5310

24.6

544

885

500 T

48 x 1.5 RE

12.5310

27.9

706

1,110

500 T

2 x 2.5 RE

7.5200

38

10.6

49

165

1000 T

3 x 2.5 RE

7.5200

32

11.1

74

190

1000 T

4 x 2.5 RE

7.5200

32

11.9

98

225

1000 T

5 x 2.5 RE

7.5200

32

12.9

123

265

1000 T

7 x 2.5 RE

7.5200

20

13.9

172

320

1000 T

12 x 2.5 RE

7.5200

17

17.7

294

495

500 T

19 x 2.5 RE

7.5200

16

20.5

466

710

500 T

Page 129

10

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHV180, 1CXKHV180
Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHV180, 1CXKHV180
24 x 2.5 RE

7.5200

13

24.1

588

890

500 T

37 x 2.5 RE

7.5200

12

27.4

907

1,270

500 T

48 x 2.5 RE

7.5200

11

31.6

1,176

1,640

500 T

2 x 4 RE

4.7000

51

11.6

78

215

1000 T

3 x 4 RE

4.7000

42

12.2

118

255

1000 T

4 x 4 RE

4.7000

42

13.2

157

305

1000 T

5 x 4 RE

4.7000

42

14.3

196

360

1000 T

7 x 4 RE

4.7000

28

15.4

274

455

1000 T

12 x 4 RE

4.7000

23

19.9

470

710

500 T

1 x 6 RE

3.1330

725

7.3

59

105

1000 T

2 x 6 RE

3.1330

64

12.6

118

275

1000 T

3 x 6 RE

3.1330

53

13.3

176

330

1000 T

4 x 6 RE

3.1330

53

14.4

235

400

1000 T

5 x 6 RE

3.1330

53

15.6

294

480

1000 T

1 x 10 RE

1.8800

99

8.1

98

145

1000 T

2 x 10 RE

1.8800

86

14.1

196

375

1000 T

3 x 10 RE

1.8800

74

14.9

294

465

1000 T

4 x 10 RE

1.8800

74

16.2

392

575

500 T

5 x 10 RE

1.8800

74

17.7

490

690

500 T

1 x 16 RE

1.1750

131

9.0

157

205

1000 T

2 x 16 RE

1.1750

110

15.9

314

520

500 T

3 x 16 RE

1.1750

98

16.9

470

660

500 T

4 x 16 RE

1.1750

98

18.3

627

820

500 T

5 x 16 RE

1.1750

98

20.1

882

995

500 T

1 x 25 RM

0.7520

177

10.8

245

300

1000 T

3 x 25 RE

0.7520

133

19.9

735

955

500 T

3 x 25 RM

0.7520

133

20.8

735

985

500 T

3 x 25 + 16 RE/RE

0.7520/1.1750

133

21.8

892

1,100

500 T

3 x 25 + 16 RM/RE

0.7520/1.1750

133

22.7

892

1,125

500 T

4 x 25 RE

0.7520

133

21.8

980

1,195

500 T

4 x 25 RM

0.7520

133

22.7

980

1,235

500 T

5 x 25 RM

0.7520

133

25.2

1,225

1,520

500 T

1 x 35 RM

0.5370

217

11.8

343

390

1000 T

3 x 35 RM

0.5370

162

22.9

1,029

1,300

500 T

3 x 35 + 16 SM/RE

0.5370/1.1750

162

24.2

1,186

1,350

500 T

3 x 35 + 25 RM/RM

0.5370/0.7520

162

25.3

1,274

1,530

500 T

3 x 35 + 25 SM/RM

0.5370/0.7520

162

24.2

1,274

1,425

500 T

4 x 35 RM

0.5370

162

25.3

1,372

1,650

500 T

4 x 35 SM

0.5370

162

24.2

1,372

1,510

500 T

5 x 35 RM

0.5370

162

27.9

1,715

2,020

500 T

Page 130

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHV180, 1CXKHV180
Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHV180, 1CXKHV180
1 x 50 RM

0.3870

265

13.7

490

555

1000 T

3 x 50 RM

0.3870

197

27.2

1,470

1,685

500 T

3 x 50 + 25 SM/RM

0.3870/0.7520

197

27.2

1,715

1,855

500 T

3 x 50 + 35 SM/RM

0.3870/0.5370

197

27.2

1,813

1,940

500 T

4 x 50 SM

0.3870

197

27.2

1,960

2,070

500 T

5 x 50 RM

0.3870

197

33.3

2,450

2,740

500 T

1 x 70 RM

0.2680

336

15.6

686

740

1000 T

3 x 70 RM

0.2680

250

31.7

2,058

2,275

500 T

3 x 70 + 35 SM/RM

0.2680/0.5370

250

31.5

2,401

2,560

500 T

3 x 70 + 50 SM/RM

0.2680/0.3870

250

31.5

2,548

2,705

500 T

4 x 70 RM

0.2680

250

34.5

2,744

2,940

500 T

4 x 70 SM

0.2680

250

31.5

2,744

2,865

500 T

5 x 70 RM

0.2680

250

38.6

3,430

3,690

500 T

1 x 95 RM

0.1980

415

17.3

931

975

1000 T

3 x 95 + 50 SM/RM

0.1980/0.3870

308

35.4

3,283

3,480

500 T

4 x 95 RM

0.1980

308

39.1

3,724

3,960

500 T

4 x 95 SM

0.1980

308

35.4

3,724

3,880

500 T

5 x 95 RM

0.1980

308

43.6

4,655

4,980

500 T

1 x 120 RM

0.1570

485

19.4

1,176

1,225

1000 T

3 x 120 + 50 SM/RM

0.1570/0.3870

359

39.1

4,018

4,135

500 T

3 x 120 + 70 SM/RM

0.1570/0.2680

359

39.1

4,214

4,305

500 T

4 x 120 SM

0.1570

359

39.1

4,704

4,735

500 T

5 x 120 RM

0.1570

359

48.6

5,880

6,120

500 T

1 x 150 RM

0.1240

557

21.0

1,470

1,505

500 T

3 x 150 + 70 SM/RM

0.1240/0.2680

412

43.7

5,096

5,230

500 T

4 x 150 SM

0.1240

412

43.7

5,880

5,935

300 T

5 x 150 RM

0.1240

412

53.3

7,350

7,635

300 T

1 x 185 RM

0.1020

646

23.4

1,813

1,865

500 T

3 x 185 + 95 SM/RM

0.1020/0.1980

475

48.7

6,370

6,560

300 T

4 x 185 SM

0.1020

475

48.7

7,252

7,355

300 T

5 x 185 RM

0.1020

475

60.0

9,065

9,510

300 T

1 x 240 RM

0.0783

774

26.0

2,352

2,410

500 T

3 x 240 + 120 SM/RM

0.0783/0.1570

564

54.9

8,232

8,320

300 T

4 x 240 SM

0.0783

564

54.9

9,408

9,380

300 T

5 x 240 RM

0.0783

564

66.3

11,760

12,230

300 T

1 x 300 RM

0.0601

901

30.6

2,940

3,040

500 T

1 x 500 RM

0.0366

1252

38.8

4,900

5,184

300 T

1 x 630 RM

0.0283

1486

40.9

6,174

6,360

300 T

1) basic rated current acc. to TP PRAKAB 02/99 5. edition


Subject to technical changes.

Page 131

10

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

N2XH
Power cables
Standard: DIN VDE 0276-604
Usage:
The cables are specified for stationary distribution of electrical
energy in dry and damp premises. Suitable for hotels, hospitals,
underground railways, airports etc to protect people and technical
building equipment in the event of fire where there is no requirement
for maintaining the function of the cable in the event of fire.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:

min. 5C
30 C to +90 C
max. +90 C
max. +250 C/5 s

Bending radius (min.): 12 x of cable


Core identification:
4

Fire properties:
flame retardant
(EN 50265-2-1, IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2,
IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A,
EN 50266-2-2)
minimum smoke emission (EN 50268-2, IEC 61034)

Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (XLPE)
3 Inner covering (halogen-free tape and halogen-free polymer
compound)
4 Sheath (halogen-free polymere compound, black)

Test certificate:

Cert
.....
..

Number
of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating in
the air1)
(A)

coloured (VDE 0276-604)

Outer
diameter
(mm) ca.

.
..

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

N2XH
2 x 1.5 RE

12.1000

29

11.5

29

180

1000 T

3 x 1.5 RE

12.1000

24

12.0

44

200

1000 T

4 x 1.5 RE

12.1000

24

13.0

59

230

1000 T

5 x 1.5 RE

12.1000

24

14.0

74

270

1000 T

7 x 1.5 RE

12.1000

14

14.0

103

310

1000 T

12 x 1.5 RE

12.1000

12

18.0

177

460

500 T

19 x 1.5 RE

12.1000

11

21.0

280

650

500 T

24 x 1.5 RE

12.1000

10

22.0

353

760

500 T

30 x 1.5 RE

12.1000

24.0

441

900

500 T

40 x 1.5 RE

12.1000

28.4

588

1,292

500 T

2 x 2.5 RE

7.4100

38

12.0

49

210

1000 T

3 x 2.5 RE

7.4100

32

13.0

74

250

1000 T

4 x 2.5 RE

7.4100

32

14.0

98

290

1000 T

5 x 2.5 RE

7.4100

32

15.0

123

340

1000 T

7 x 2.5 RE

7.4100

20

15.9

172

400

1000 T

12 x 2.5 RE

7.4100

17

19.0

294

600

500 T

19 x 2.5 RE

7.4100

16

22.0

466

840

500 T

24 x 2.5 RE

7.4100

13

25.0

588

1,050

500 T

30 x 2.5 RE

7.4100

12

27.0

735

1,230

500 T

40 x 2.5 RE

7.4100

11

31.7

980

1,814

500 T

2 x 4 RE

4.6100

51

13.0

79

270

1000 T

Page 132

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

N2XH
Number
of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating in
the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

N2XH
3 x 4 RE

4.6100

42

14.0

117

330

1000 T

4 x 4 RE

4.6100

42

15.0

157

380

1000 T

5 x 4 RE

4.6100

42

16.0

196

450

1000 T

7 x 4 RE

4.6100

28

18.5

275

620

500 T

2 x 6 RE

3.0800

64

14.0

117

340

500 T

3 x 6 RE

3.0800

53

15.0

177

410

500 T

4 x 6 RE

3.0800

53

16.0

235

490

500 T

5 x 6 RE

3.0800

53

17.0

294

560

500 T

2 x 10 RE

1.8300

86

16.0

196

450

500 T

3 x 10 RE

1.8300

74

16.0

294

550

500 T

4 x 10 RE

1.8300

74

18.0

392

670

500 T

5 x 10 RE

1.8300

74

19.0

490

790

500 T

2 x 16 RM

1.1500

110

18.1

313

632

500 T

3 x 16 RM

1.1500

98

19.2

471

747

500 T

4 x 16 RM

1.1500

98

20.8

627

958

500 T

5 x 16 RM

1.1500

98

22.7

784

1,085

500 T

3 x 25 RM

0.7270

133

24.0

735

1,200

500 T

4 x 25 RM

0.7270

133

26.0

980

1,450

500 T

3 x 35 RM

0.5240

162

27.0

1,029

1,600

500 T

4 x 35 SM

0.5240

162

28.4

1,372

1,846

500 T

3 x 50 RM

0.3870

197

29.0

1,470

1,800

500 T

4 x 50 SM

0.3870

197

34.4

1,960

2,408

500 T

3 x 70 RM

0.2680

250

34.6

2,058

2,545

500 T

4 x 70 SM

0.2680

250

37.8

2,744

3,335

500 T

3 x 95 RM

0.1930

308

38.1

2,793

3,356

500 T

4 x 95 SM

0.1930

308

42.8

3,724

4,379

500 T

3 x 120 RM

0.1530

359

41.7

3,528

4,152

500 T

4 x 120 SM

0.1530

359

46.2

4,704

5,416

500 T

3 x 150 RM

0.1240

412

45.4

4,410

5,180

300 T

4 x 150 SM

0.1240

412

50.0

5,880

6,690

300 T

3 x 185 RM

0.0991

475

51.0

5,439

6,235

300 T

4 x 185 SM

0.0991

475

56.6

7,252

8,263

300 T

3 x 240 RM

0.0754

564

57.0

7,056

8,288

300 T

4 x 240 SM

0.0754

564

62.8

9,408

11,108

300 T

1) basic rated current acc. to VDE 0276-604


Subject to technical changes.

Page 133

10

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

SKW | PRAKAB | Products

NHXH FE180/E30, (N)HXH FE180/E30


Power cables with insulation integrity FE180 and functional integrity E30
Standard: DIN VDE 0266 (NHXH), resp. adapted
to DIN VDE 0266 ((N)HXH)
Usage:
For fixed installation in interior premises and in the open air and for
direct burial in cable ducts and conduit. Since they are free from halogens and exhibit enhanced fire performance, these cables are used
in those applications where in the event of fire, the negative effects
on concentrations of people and valuable material goods must be
minimised..

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
operating temperature:

min. 5 C
fixed 40 C to +80 C
in motion 5 C to +50 C
conductor temperature: max. +90 C
short-circuit
temperature:
max. +250 C/5 s
Bending radius (min.): 15 x of cable
(single core)
12 x of cable
(multi core)

Core identification:
Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Flame protection by conductor taping (mica tape, only for NHXH)
or by a ceramising halogen-free polymer compound
3 Core insulation (halogen-free polymer compound, cross linked)
4 Taping (halogen-free glass fabric tape)
5 Inner covering (halogen-free polymer compound) in case
of multicore constructions
6 Sheath (halogen-free polyolefin compound, orange)

Fire properties:
flame retardant

(EN 50265-2-1,
IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2,
IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A, EN
50266-2-2, DIN VDE
0472-804)
minimum smoke emission
(EN 50268-2, IEC 61034)
insulation integrity FE180 (IEC 60331,
DIN VDE 0472-814)
functional integrity E30 (DIN VDE 4102-12)
Test certificate:

Cert
.....
..

Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

1 x 16 RE

1.1500

10.0

1 x 25 RM

0.7270

1 x 35 RM
1 x 50 RM

coloured (HD 308 S2)

.
..

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

160

230

500 T, 1000 T

11.0

250

340

500 T, 1000 T

0.5240

12.0

350

440

500 T, 1000 T

0.3870

14.0

500

620

500 T, 1000 T

1 x 70 RM

0.2680

16.0

700

850

500 T, 1000 T

1 x 95 RM

0.1930

18.0

950

1,100

500 T, 1000 T

1 x 120 RM

0.1530

19.0

1,200

1,350

500 T, 1000 T

1 x 150 RM

0.1240

22.0

1,500

1,650

500 T, 1000 T

1 x 185 RM

0.0991

24.0

1,850

2,100

500 T, 1000 T

1 x 240 RM

0.0754

27.0

2,400

2,600

500 T, 1000 T

1 x 300 RM

0.0601

30.0

3,000

3,300

500 T, 1000 T

NHXH FE180/E30, (N)HXH FE180/E30

Page 134

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

NHXH FE180/E30, (N)HXH FE180/E30


Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

NHXH FE180/E30, (N)HXH FE180/E30


2 x 1.5 RE

12.1000

12.0

30

200

500 T, 1000 T

3 x 1.5 RE

12.1000

13.0

45

210

500 T, 1000 T

4 x 1.5 RE

12.1000

14.0

60

280

500 T, 1000 T

5 x 1.5 RE

12.1000

15.0

75

330

500 T, 1000 T

2 x 2.5 RE

7.4100

13.0

50

220

500 T, 1000 T

3 x 2.5 RE

7.4100

13.5

75

230

500 T, 1000 T

4 x 2.5 RE

7.4100

15.0

100

350

500 T, 1000 T

5 x 2.5 RE

7.4100

17.0

125

410

500 T, 1000 T

2 x 4 RE

4.6100

14.0

80

310

500 T, 1000 T

3 x 4 RE

4.6100

15.0

120

300

500 T, 1000 T

4 x 4 RE

4.6100

17.0

160

440

500 T, 1000 T

5 x 4 RE

4.6100

18.0

200

520

500 T, 1000 T

2 x 6 RE

3.0800

15.0

120

380

500 T, 1000 T

3 x 6 RE

3.0800

16.0

180

380

500 T, 1000 T

4 x 6 RE

3.0800

18.0

240

560

500 T, 1000 T

5 x 6 RE

3.0800

20.0

300

660

500 T, 1000 T

2 x 10 RE

1.8300

17.0

200

490

500 T, 1000 T

3 x 10 RE

1.8300

18.0

300

500

500 T, 1000 T

4 x 10 RE

1.8300

20.0

400

760

500 T, 1000 T

5 x 10 RE

1.8300

21.0

500

950

500 T, 1000 T

2 x 16 RE

1.1500

19.0

320

680

500 T, 1000 T

3 x 16 RE

1.1500

20.0

480

702

500 T, 1000 T

4 x 16 RE

1.1500

23.0

640

1,100

500 T, 1000 T

5 x 16 RE

1.1500

23.0

800

1,300

500 T, 1000 T

3 x 25 RM

0.7270

24.0

750

1,200

500 T, 1000 T

4 x 25 RM

0.7270

26.0

1,000

1,600

500 T, 1000 T

5 x 25 RM

0.7270

29.0

1,250

2,000

500 T, 1000 T

3 x 35 RM

0.5240

27.0

1,050

1,520

500 T, 1000 T

4 x 35 RM

0.5240

28.0

1,400

2,100

500 T, 1000 T

3 x 50 RM

0.3870

30.0

1,500

2,100

500 T, 1000 T

4 x 50 RM

0.3870

33.0

2,000

2,900

500 T, 1000 T

3 x 70 RM

0.2680

33.0

2,100

2,700

500 T, 1000 T

4 x 70 RM

0.2680

37.0

2,800

3,900

500 T, 1000 T

3 x 95 RM

0.1930

38.0

2,850

3,700

500 T, 1000 T

4 x 95 RM

0.1930

43.0

3,800

5,200

500 T, 1000 T

3 x 120 RM

0.1530

43.0

3,600

4,600

500 T, 1000 T

4 x 120 RM

0.1530

47.0

4,800

6,300

500 T, 1000 T

3 x 150 RM

0.1240

47.0

4,500

5,800

500 T, 1000 T

4 x 150 RM

0.1240

49.0

6,000

6,450

500 T, 1000 T

3 x 185 RM

0.0991

52.0

5,550

7,200

500 T

Page 135

10

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

NHXH FE180/E30, (N)HXH FE180/E30


Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

NHXH FE180/E30, (N)HXH FE180/E30


4 x 185 RM

0.0991

53.0

7,400

8,200

500 T

3 x 240 RM

0.0754

56.0

7,200

8,300

500 T

4 x 240 RM

0.0754

60.0

9,600

10,700

500 T

7 x 1.5 RE

12.1000

16.0

105

380

500 T, 1000 T

10 x 1.5 RE

12.1000

20.0

150

520

500 T, 1000 T

12 x 1.5 RE

12.1000

21.0

180

580

500 T, 1000 T

14 x 1.5 RE

12.1000

22.0

210

660

500 T, 1000 T

19 x 1.5 RE

12.1000

25.0

285

850

500 T, 1000 T

24 x 1.5 RE

12.1000

29.0

360

1,050

500 T, 1000 T

30 x 1.5 RE

12.1000

30.0

450

1,200

500 T, 1000 T

7 x 2.5 RE

7.4100

20.0

175

480

500 T, 1000 T

10 x 2.5 RE

7.4100

25.0

250

680

500 T, 1000 T

12 x 2.5 RE

7.4100

26.0

300

780

500 T, 1000 T

14 x 2.5 RE

7.4100

27.0

350

900

500 T, 1000 T

19 x 2.5 RE

7.4100

29.0

475

1,100

500 T, 1000 T

24 x 2.5 RE

7.4100

34.0

600

1,350

500 T, 1000 T

30 x 2.5 RE

7.4100

36.0

750

1,650

500 T, 1000 T

7 x 4 RE

4.6100

22.0

280

640

500 T, 1000 T

10 x 4 RE

4.6100

27.0

400

900

500 T, 1000 T

12 x 4 RE

4.6100

28.0

480

1,050

500 T, 1000 T

7 x 6 RE

3.0800

23.0

420

800

500 T, 1000 T

10 x 6 RE

3.0800

29.0

600

1,150

500 T, 1000 T

12 x 6 RE

3.0800

30.0

720

1,300

500 T, 1000 T

3 x 25 + 16 RM

0.727/1.150

26.0

910

1,400

500 T, 1000 T

3 x 35 + 16 RM

0.524/1.150

27.0

1,210

1,600

500 T, 1000 T

3 x 50 + 25 RM

0.387/0.727

31.0

1,750

2,400

500 T, 1000 T

3 x 70 + 35 RM

0.268/0.524

36.0

2,450

3,200

500 T, 1000 T

3 x 95 + 50 RM

0.193/0.387

41.0

3,350

4,400

500 T, 1000 T

3 x 120 + 70 RM

0.153/0.268

46.0

4,300

5,400

500 T, 1000 T

3 x 150 + 70 RM

0.120/0.268

49.0

5,200

6,600

500 T, 1000 T

3 x 185 + 95 RM

0.0991/0.193

56.0

6,500

8,300

500 T

3 x 240 + 120 RM

0.0754/0.153

64.0

8,400

10,500

500 T

Subject to technical changes.

Page 136

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

SKW | PRAKAB | Products

NHXH FE180/E90
Power cables with insulation integrity FE180 and functional integrity E90
Standard: DIN VDE 0266
Usage:
For fixed installation in interior premises and in the open air and for
direct burial in cable ducts and conduit. Since they are free from halogens and exhibit enhanced fire performance, these cables are used
in those applications where in the event of fire, the negative effects
on concentrations of people and valuable material goods must be
minimised.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
min. 5 C
operating temperature: fixed 40 C to +80 C
in motion 5 C to +50 C
conductor temperature: max. +90 C
short-circuit
temperature:
max. +250 C/5 s
Bending radius (min.): 15 x of cable
(single core
12 x of cable
(multi core)

Core identification:
Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Flame protection by conductor taping (mica tape)
3 Core insulation (halogen-free polymer compound, cross linked)
4 Taping (halogen-free glass fabric tape)
5 Inner covering (halogen-free polymer compound) in case
of multicore constructions
6 Sheath (halogen-free polyolefin compound, orange)

Fire properties:
flame retardant

(EN 50265-2-1,
IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2,
IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A,
EN 50266-2-2,
DIN VDE 0472-804)
minimum smoke emission
(EN 50268-2, IEC 61034)
insulation integrity FE180 (IEC 60331,
DIN VDE 0472-814)
functional integrity E90 (DIN VDE 4102-12)
Test certificate:

Cert
.....
..

Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

coloured (HD 308 S2)

.
..

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

NHXH FE180/E90
1 x 16 RE

1.1500

11.0

160

230

500 T, 1000 T

1 x 25 RM

0.7270

13.0

250

340

500 T, 1000 T

1 x 35 RM

0.5240

14.0

350

440

500 T, 1000 T

1 x 50 RM

0.3870

16.0

500

620

500 T, 1000 T

1 x 70 RM

0.2680

18.0

700

850

500 T, 1000 T

1 x 95 RM

0.1930

20.0

950

1,100

500 T, 1000 T

1 x 120 RM

0.1530

21.0

1,200

1,350

500 T, 1000 T

1 x 150 RM

0.1240

24.0

1,500

1,650

500 T, 1000 T

1 x 185 RM

0.0991

26.0

1,850

2,100

500 T, 1000 T

1 x 240 RM

0.0754

29.0

2,400

2,600

500 T, 1000 T

1 x 300 RM

0.0601

32.0

3,000

3,300

500 T, 1000 T

Page 137

10

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

NHXH FE180/E90
Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

NHXH FE180/E90
2 x 1.5 RE

12.1000

14.0

30

210

500 T, 1000 T

3 x 1.5 RE

12.1000

15.0

45

240

500 T, 1000 T

4 x 1.5 RE

12.1000

16.0

60

280

500 T, 1000 T

5 x 1.5 RE

12.1000

17.0

75

330

500 T, 1000 T

2 x 2.5 RE

7.4100

14.0

50

250

500 T, 1000 T

3 x 2.5 RE

7.4100

15.0

75

290

500 T, 1000 T

4 x 2.5 RE

7.4100

17.0

100

350

500 T, 1000 T

5 x 2.5 RE

7.4100

19.0

125

410

500 T, 1000 T

2 x 4 RE

4.6100

16.0

80

310

500 T, 1000 T

3 x 4 RE

4.6100

17.0

120

360

500 T, 1000 T

4 x 4 RE

4.6100

19.0

160

440

500 T, 1000 T

5 x 4 RE

4.6100

20.0

200

520

500 T, 1000 T

2 x 6 RE

3.0800

17.0

120

380

500 T, 1000 T

3 x 6 RE

3.0800

18.0

180

450

500 T, 1000 T

4 x 6 RE

3.0800

20.0

240

560

500 T, 1000 T

5 x 6 RE

3.0800

22.0

300

660

500 T, 1000 T

2 x 10 RE

1.8300

19.0

200

510

500 T, 1000 T

3 x 10 RE

1.8300

20.0

300

620

500 T, 1000 T

4 x 10 RE

1.8300

22.0

400

760

500 T, 1000 T

5 x 10 RE

1.8300

24.0

500

950

500 T, 1000 T

2 x 16 RE

1.1500

21.0

320

680

500 T, 1000 T

3 x 16 RE

1.1500

22.0

480

850

500 T, 1000 T

4 x 16 RE

1.1500

25.0

640

1,100

500 T, 1000 T

5 x 16 RE

1.1500

27.0

800

1,300

500 T, 1000 T

3 x 25 RM

0.7270

26.0

750

1 300

500 T, 1000 T

4 x 25 RM

0.7270

30.0

1,000

1 600

500 T, 1000 T

5 x 25 RM

0.7270

32.0

1,250

2 000

500 T, 1000 T

3 x 35 RM

0.5240

29.0

1,050

1,650

500 T, 1000 T

4 x 35 RM

0.5240

32.0

1,400

2,100

500 T, 1000 T

3 x 50 RM

0.3870

32.0

1,500

2,300

500 T, 1000 T

4 x 50 RM

0.3870

37.0

2,000

2,900

500 T, 1000 T

3 x 70 RM

0.2680

36.0

2,100

3,000

500 T, 1000 T

4 x 70 RM

0.2680

41.0

2,800

3,900

500 T, 1000 T

3 x 95 RM

0.1930

41.0

2,850

4,000

500 T, 1000 T

4 x 95 RM

0.1930

47.0

3,800

5,200

500 T, 1000 T

3 x 120 RM

0.1530

45.0

3,600

4,900

500 T, 1000 T

4 x 120 RM

0.1530

49.0

4,800

6,300

500 T, 1000 T

3 x 150 RM

0.1240

50.0

4,500

6,100

500 T

4 x 150 RM

0.1240

51.0

6,000

6,450

500 T

3 x 185 RM

0.0991

53.0

5,550

7,500

500 T

Page 138

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

NHXH FE180/E90
Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

NHXH FE180/E90
4 x 185 RM

0.0991

55.0

7,400

8,200

500 T

3 x 240 RM

0.0754

56.0

7,200

8,300

500 T

4 x 240 RM

0.0754

62.0

9,600

10,700

500 T

7 x 1.5 RE

12.1000

19.0

105

380

500 T, 1000 T

10 x 1.5 RE

12.1000

23.0

150

520

500 T, 1000 T

12 x 1.5 RE

12.1000

24.0

180

580

500 T, 1000 T

14 x 1.5 RE

12.1000

25.0

210

660

500 T, 1000 T

19 x 1.5 RE

12.1000

27.0

285

850

500 T, 1000 T

24 x 1.5 RE

12.1000

31.0

360

1,050

500 T, 1000 T

30 x 1.5 RE

12.1000

33.0

450

1,200

500 T, 1000 T

7 x 2.5 RE

7.4100

20.0

175

480

500 T, 1000 T

10 x 2.5 RE

7.4100

25.0

250

680

500 T, 1000 T

12 x 2.5 RE

7.4100

26.0

300

780

500 T, 1000 T

14 x 2.5 RE

7.4100

27.0

350

900

500 T, 1000 T

19 x 2.5 RE

7.4100

29.0

475

1,100

500 T, 1000 T

24 x 2.5 RE

7.4100

34.0

600

1,350

500 T, 1000 T

30 x 2.5 RE

7.4100

36.0

750

1,650

500 T, 1000 T

7 x 4 RE

4.6100

22.0

280

640

500 T, 1000 T

10 x 4 RE

4.6100

27.0

400

900

500 T, 1000 T

12 x 4 RE

4.6100

28.0

480

1,050

500 T, 1000 T

7 x 6 RE

3.0800

23.0

420

800

500 T, 1000 T

10 x 6 RE

3.0800

29.0

600

1,150

500 T, 1000 T

12 x 6 RE

3.0800

30.0

720

1,300

500 T, 1000 T

3 x 25 + 16 RM

0.727/1.150

28.0

910

1,500

500 T, 1000 T

3 x 35 + 16 RM

0.524/1.150

30.0

1,210

1,800

500 T, 1000 T

3 x 50 + 25 RM

0.387/0.727

35.0

1,750

2,600

500 T, 1000 T

3 x 70 + 35 RM

0.268/0.524

39.0

2,450

3,400

500 T, 1000 T

3 x 95 + 50 RM

0.193/0.387

44.0

3,350

4,600

500 T, 1000 T

3 x 120 + 70 RM

0.153/0.268

49.0

4,300

5,700

500 T, 1000 T

3 x 150 + 70 RM

0.124/0.268

52.0

5,200

6,800

500 T

3 x 185 + 95 RM

0.0991/0.193

59.0

6,500

8,500

500 T

3 x 240 + 120 RM

0.0754/0.153

68.0

8,400

11,000

500 T

Subject to technical changes.

10

Page 139

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHDHR, 1CXKHDHR
Power cables, steel wire armoured

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Standard: TP PRAKAB 02/99 5. edition


Usage:
These cables with enhanced mechanical protection are intended for
stationary distribution of electrical energy in dry and damp premises.
Suitable for hotels, hospitals, underground railways, airports etc to
protect people and technical building equipment in the event of fire
where there is no requirement for maintaining the function of the
cable in the event of fire.

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:
Bending radius (min.):

Core identification:

5 4 3

Max. conductor
resistance
(/km)

Current rating
in the air1)
(A)

max. 250 C/5 s


6 x for < 20 mm
12 x for 20 to 40 mm
15 x for > 40 mm
coloured (HD 308 S2)

Fire properties:
flame retardant
(EN 50265-2-1, IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2,
IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A,
EN 50266-2-2,
DIN VDE 0472-804)
minimum smoke emission
(EN 50268-2, IEC 61034)

Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (halogen-free polymer /1-CHKHDH-R,
XLPE/1-CXKHDH-R)
3 Inner covering (halogen-free tape)
4 Sheath (halogen-free polymer compound)
5 Armouring (galvanized steel wires)
6 Sheath (halogen-free polymer compound, orange)

Number of cores x
nominal
cross section
(mm2)

min. 5 C
30 C to +90 C
max. +90 C

Test certificate:

Cert
.....
..

.
..

EZ Czech Republic,
GOST Russia
(only 1CHKHDHR

.. .. ...
Sz JZD .
. . ..
.

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHDHR, 1CXKHDHR
2 x 1.5 RE

12.5310

29

16.8

29

588

1000 T

3 x 1.5 RE

12.5310

24

17.2

44

623

1000 T

4 x 1.5 RE

12.5310

24

18.0

59

670

1000 T

5 x 1.5 RE

12.5310

24

18.8

74

731

1000 T

7 x 1.5 RE

12.5310

14

19.7

103

811

1000 T

12 x 1.5 RE

12.5310

12

23.2

176

1,077

500 T

19 x 1.5 RE

12.5310

11

26.4

279

1,391

500 T

24 x 1.5 RE

12.5310

10

29.4

353

1,632

500 T

37 x 1.5 RE

12.5310

32.6

544

2,059

500 T

48 x 1.5 RE

12.5310

36.0

706

2,454

500 T

2 x 2.5 RE

7.5200

38

17.6

49

654

1000 T

3 x 2.5 RE

7.5200

32

18.1

74

698

1000 T

4 x 2.5 RE

7.5200

32

18.9

98

769

1000 T

5 x 2.5 RE

7.5200

32

19.9

123

844

1000 T

7 x 2.5 RE

7.5200

20

20.9

172

945

1000 T

12 x 2.5 RE

7.5200

17

25.6

294

1,332

500 T

19 x 2.5 RE

7.5200

16

28.4

466

1,675

500 T

Page 140

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHDHR, 1CXKHDHR
Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHDHR, 1CXKHDHR
24 x 2.5 RE

7.5200

13

32.0

588

2,024

500 T

37 x 2.5 RE

7.5200

12

35.4

907

2,575

500 T

48 x 2.5 RE

7.5200

11

42.6

1,176

4,052

500 T

2 x 4 RE

4.7000

51

18.6

78

736

1000 T

3 x 4 RE

4.7000

42

19.2

118

800

1000 T

4 x 4 RE

4.7000

42

20.2

157

887

1000 T

5 x 4 RE

4.7000

42

21.3

196

995

1000 T

7 x 4 RE

4.7000

28

22.5

274

1,143

500 T

12 x 4 RE

4.7000

23

27.7

470

1,639

500 T

2 x 6 RE

3.1330

64

19.6

118

828

1000 T

3 x 6 RE

3.1330

53

22.4

176

967

1000 T

4 x 6 RE

3.1330

53

21.4

235

1,031

1000 T

5 x 6 RE

3.1330

53

22.6

294

1,162

1000 T

1 x 10 RE

1.8800

99

14.5

98

573

1000 T

2 x 10 RE

1.8800

86

21.1

196

979

1000 T

3 x 10 RE

1.8800

74

21.9

294

1,105

1000 T

4 x 10 RE

1.8800

74

23.2

392

1,266

500 T

5 x 10 RE

1.8800

74

25.5

490

1,488

500 T

1 x 16 RE

1.1750

131

15.4

157

646

1000 T

2 x 16 RE

1.1750

110

22.9

314

1,224

1000 T

3 x 16 RE

1.1750

98

24.6

470

1,426

500 T

4 x 16 RE

1.1750

98

26.2

627

1,644

500 T

5 x 16 RE

1.1750

98

27.9

882

1,894

500 T

1 x 25 RM

0.7520

177

17.2

245

772

500 T

3 x 25 RE

0.7520

133

26.5

735

1,710

500 T

3 x 25 RM

0.7520

133

28.2

735

1,899

500 T

3 x 25 + 16 RE/RE

0.7520/1.1750

133

28.3

892

1,910

500 T

3 x 25 + 16 RM/RE

0.7520/1.1750

133

30.2

892

2,125

500 T

4 x 25 RE

0.7520

133

28.3

980

2,095

500 T

4 x 25 RM

0.7520

133

30.2

980

2,224

500 T

5 x 25 RM

0.7520

133

32.6

1,225

2,606

500 T

1 x 35 RM

0.5370

217

18.2

343

883

500 T

3 x 35 RM

0.5370

162

30.4

1,029

2,292

500 T

3 x 35 + 16 SM/RE

0.5370/1.1750

162

30.5

1,186

2,350

500 T

3 x 35 + 25 RM/RM

0.5370/0.7520

162

32.8

1,274

2,524

500 T

3 x 35 + 25 SM/RM

0.5370/0.7520

162

30.5

1,274

2,496

500 T

4 x 35 RM

0.5370

162

32.8

1,372

2,736

500 T

4 x 35 SM

0.5370

162

30.5

1,372

2,705

500 T

5 x 35 RM

0.5370

162

35.3

1,715

3,210

500 T

1 x 50 RM

0.3870

265

20.0

490

1,113

500 T

Page 141

10

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHDHR, 1CXKHDHR
Number of cores x
nominal
cross section
(mm2)

Max. conductor
resistance
(/km)

Current rating
in the air1)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHDHR, 1CXKHDHR
3 x 50 RM

0.3870

197

34.7

1,470

2,850

500 T

3 x 50 + 25 SM/RM

0.3870/0.7520

197

34.7

1,715

2,932

500 T

3 x 50 + 35 SM/RM

0.3870/0.5370

197

34.7

1,813

2,960

500 T

4 x 50 SM

0.3870

197

34.7

1,960

3,064

500 T

5 x 50 RM

0.3870

197

43.7

2,450

5,074

500 T

1 x 70 RM

0.2680

336

21.7

686

1,380

500 T

3 x 70 RM

0.2680

250

41.8

2,058

4,496

500 T

3 x 70 + 35 SM/RM

0.2680/0.5370

250

41.5

2,401

4,786

500 T

3 x 70 + 50 SM/RM

0.2680/0.3870

250

41.5

2,548

4,905

500 T

4 x 70 RM

0.2680

250

43.6

2,744

5,130

500 T

4 x 70 SM

0.2680

250

41.5

2,744

5,082

500 T

5 x 70 RM

0.2680

250

48.5

3,430

6,334

500 T

1 x 95 RM

0.1980

415

24.5

931

1,751

500 T

3 x 95 + 50 SM/RM

0.1980/0.3870

308

46.1

3,283

5,977

500 T

4 x 95 RM

0.1980

308

49.6

3,724

6,650

500 T

4 x 95 SM

0.1980

308

46.1

3,724

6,385

500 T

5 x 95 RM

0.1980

308

54.0

4,655

7,977

500 T

1 x 120 RM

0.1570

485

26.2

1,176

2,062

500 T

3 x 120 + 50 SM/RM

0.1570/0.3870

359

48.2

4,018

6,915

500 T

3 x 120 + 70 SM/RM

0.1570/0.2680

359

48.2

4,214

7,089

500 T

4 x 120 SM

0.1570

359

48.2

4,704

7,135

500 T

1 x 150 RM

0.1240

557

27.6

1,470

2,413

500 T

1 x 185 RM

0.1020

646

29.8

1,813

2,834

300 T

1 x 240 RM

0.0783

774

32.3

2,352

3,501

300 T

1 x 300 RM

0.0601

901

36.7

2,940

3,985

300 T

1 x 500 RM

0.0366

1252

45.1

4,900

7,605

300 T

1 x 630 RM

0.0283

1486

48.9

6,174

8,982

300 T

1) basic rated current acc. to TP PRAKAB 02/99 5. edition


Subject to technical changes.

Page 142

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHDHV180, 1CXKHDHV180
Power cables, with insulation integrity FE180,
steel wire armoured
Standard: TP PRAKAB 02/99 5. edition

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Usage:
These cables with enhanced mechanical protection are intended for
stationary distribution of electrical energy in dry and damp premises.
Suitable for hotels, hospitals, underground railways, airports etc to
protect people and technical building equipment in the event of fire
where there is a requirement for maintaining the function of the cable
in the event of fire.

Temperature range:
laying temperature:
operating temperature:
conductor temperature:
short-circuit
temperature:
Bending radius (min.):

Core identification:

Max. conductor Current rating in


resistance
the air1)
(/km)
(A)

max. +250 C/5 s


6 x for < 20 mm
12 x for 20 to 40 mm
15 x for > 40 mm
coloured (HD 308 S2)

Fire properties:
flame retardant
(EN 50265-2-1, IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2, IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A,
EN 50266-2-2,
DIN VDE 0472-804)
minimum smoke emission
(EN 50268-2, IEC 61034)
insulation integrity FE180 (IEC 60331,
DIN VDE 0472-814)

7
6 5 4 3 2 1
Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Flame protection (mica tape)
3 Core insulation (halogen-free polymer /1-CHKHDH-V180,
XLPE/1-CXKHDH-V180)
4 Inner covering (halogen-free tape)
5 Sheath (halogen-free polymer compound)
6 Armouring (galvanized steel wires)
7 Sheath (halogen-free polymer compound, brown)

Number of cores x
nominal
cross section
(mm2)

min. 5 C
30 C to +90 C
max. +90 C

Test certificate:

Cert
.....
..

Outer
diameter
(mm) ca.

.
..

EZ Czech Republic,
GOST Russia
(only 1CHKHDHV180)

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHDHV180, 1CXKHDHV180
2 x 1.5 RE

12.5310

29

16.8

29

588

1000 T

3 x 1.5 RE

12.5310

24

17.2

44

623

1000 T

4 x 1.5 RE

12.5310

24

18.0

59

670

1000 T

5 x 1.5 RE

12.5310

24

18.8

74

731

1000 T

7 x 1.5 RE

12.5310

14

19.7

103

811

1000 T

12 x 1.5 RE

12.5310

12

23.2

176

1,077

500 T

19 x 1.5 RE

12.5310

11

26.4

279

1,391

500 T

24 x 1.5 RE

12.5310

10

29.4

353

1,632

500 T

37 x 1.5 RE

12.5310

32.6

544

2,059

500 T

48 x 1.5 RE

12.5310

36.0

706

2,454

500 T

2 x 2.5 RE

7.5200

38

17.6

49

654

1000 T

3 x 2.5 RE

7.5200

32

18.1

74

698

1000 T

4 x 2.5 RE

7.5200

32

18.9

98

769

1000 T

5 x 2.5 RE

7.5200

32

19.9

123

844

1000 T

7 x 2.5 RE

7.5200

20

20.9

172

945

1000 T

12 x 2.5 RE

7.5200

17

25.6

294

1,332

500 T

19 x 2.5 RE

7.5200

16

28.4

466

1,675

500 T

Page 143

10

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHDHV180, 1CXKHDHV180
Number of cores x
nominal
cross section
(mm2)

Max. conductor Current rating in


resistance
the air1)
(/km)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHDHV180, 1CXKHDHV180
24 x 2.5 RE

7.5200

13

32.0

588

2,024

500 T

37 x 2.5 RE

7.5200

12

35.4

907

2,575

500 T

48 x 2.5 RE

7.5200

11

42.6

1,176

4,052

500 T

2 x 4 RE

4.7000

51

18.6

78

736

1000 T

3 x 4 RE

4.7000

42

19.2

118

800

1000 T

4 x 4 RE

4.7000

42

20.2

157

887

1000 T

5 x 4 RE

4.7000

42

21.3

196

995

1000 T

7 x 4 RE

4.7000

28

22.5

274

1,143

500 T

12 x 4 RE

4.7000

23

27.7

470

1,639

500 T

2 x 6 RE

3.1330

64

19.6

118

828

1000 T

3 x 6 RE

3.1330

53

22.4

176

967

1000 T

4 x 6 RE

3.1330

53

21.4

235

1,031

1000 T

5 x 6 RE

3.1330

53

22.6

294

1,162

1000 T

1 x 10 RE

1.8800

99

14.5

98

573

1000 T

2 x 10 RE

1.8800

86

21.1

196

979

1000 T

3 x 10 RE

1.8800

74

21.9

294

1,105

1000 T

4 x 10 RE

1.8800

74

23.2

392

1,266

500 T

5 x 10 RE

1.8800

74

25.5

490

1,488

500 T

1 x 16 RE

1.1750

131

15.4

157

646

1000 T

2 x 16 RE

1.1750

110

22.9

314

1,224

1000 T

3 x 16 RE

1.1750

98

24.6

470

1,426

500 T

4 x 16 RE

1.1750

98

26.2

627

1,644

500 T

5 x 16 RE

1.1750

98

27.9

882

1,894

500 T

1 x 25 RM

0.7520

177

17.2

245

772

500 T

3 x 25 RE

0.7520

133

26.5

735

1,710

500 T

3 x 25 RM

0.7520

133

28.2

735

1,899

500 T

3 x 25 + 16 RE/RE

0.7520/1.1750

133

28.3

892

1,910

500 T

3 x 25 + 16 RM/RE

0.7520/1.1750

133

30.2

892

2,125

500 T

4 x 25 RE

0.7520

133

28.3

980

2,095

500 T

4 x 25 RM

0.7520

133

30.2

980

2,224

500 T

5 x 25 RM

0.7520

133

32.6

1,225

2,606

500 T

1 x 35 RM

0.5370

217

18.2

343

883

500 T

3 x 35 RM

0.5370

162

30.4

1,029

2,292

500 T

3 x 35 + 16 SM/RE

0.5370/1.1750

162

30.5

1,186

2,350

500 T

3 x 35 + 25 RM/RM

0.5370/0.7520

162

32.8

1,274

2,524

500 T

3 x 35 + 25 SM/RM

0.5370/0.7520

162

30.5

1,274

2,496

500 T

4 x 35 RM

0.5370

162

32.8

1,372

2,736

500 T

4 x 35 SM

0.5370

162

30.5

1,372

2,705

500 T

5 x 35 RM

0.5370

162

35.3

1,715

3,210

500 T

1 x 50 RM

0.3870

265

20.0

490

1,113

500 T

Page 144

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

1CHKHDHV180, 1CXKHDHV180
Number of cores x
nominal
cross section

Max. conductor Current rating in


resistance
the air1)
(/km)
(A)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard
lenghts/
packing
(m)

1CHKHDHV180, 1CXKHDHV180
3 x 50 RM

0.3870

197

34.7

1,470

2,850

500 T

3 x 50 + 25 SM/RM

0.3870/0.7520

197

34.7

1,715

2,932

500 T

3 x 50 + 35 SM/RM

0.3870/0.5370

197

34.7

1,813

2,960

500 T

4 x 50 SM

0.3870

197

34.7

1,960

3,064

500 T

5 x 50 RM

0.3870

197

43.7

2,450

5,074

500 T

1 x 70 RM

0.2680

336

21.7

686

1,380

500 T

3 x 70 RM

0.2680

250

41.8

2,058

4,496

500 T

3 x 70 + 35 SM/RM

0.2680/0.5370

250

41.5

2,401

4,786

500 T

3 x 70 + 50 SM/RM

0.2680/0.3870

250

41.5

2,548

4,905

500 T

4 x 70 RM

0.2680

250

43.6

2,744

5,130

500 T

4 x 70 SM

0.2680

250

41.5

2,744

5,082

500 T

5 x 70 RM

0.2680

250

48.5

3,430

6,334

500 T

1 x 95 RM

0.1980

415

24.5

931

1,751

500 T

3 x 95 + 50 SM/RM

0.1980/0.3870

308

46.1

3,283

5,977

500 T

4 x 95 RM

0.1980

308

49.6

3,724

6,650

500 T

4 x 95 SM

0.1980

308

46.1

3,724

6,385

500 T

5 x 95 RM

0.1980

308

54.0

4,655

7,977

500 T

1 x 120 RM

0.1570

485

26.2

1,176

2,062

500 T

3 x 120 + 50 SM/RM

0.1570/0.3870

359

48.2

4,018

6,915

500 T

3 x 120 + 70 SM/RM

0.1570/0.2680

359

48.2

4,214

7,089

500 T

4 x 120 SM

0.1570

359

48.2

4,704

7,135

500 T

1 x 150 RM

0.1240

557

27.6

1,470

2,413

500 T

1 x 185 RM

0.1020

646

29.8

1,813

2,834

300 T

1 x 240 RM

0.0783

774

32.3

2,352

3,501

300 T

1 x 300 RM

0.0601

901

36.7

2,940

3,985

300 T

1 x 500 RM

0.0366

1252

45.1

4,900

7,605

300 T

1 x 630 RM

0.0283

1486

48.9

6,174

8,982

300 T

1) basic rated current acc. to TP PRAKAB 02/99 5. edition


Subject to technical changes.

10

Page 145

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

N2XCH
Power cables, screened
Standard: DIN VDE 0276-604
Usage:
The cables are specified for stationary distribution of electrical
energy in dry and damp premises. Suitable for hotels, hospitals,
underground railways, airports etc to protect people and technical
building equipment in the event of fire where there is no requirement
for maintaining the function of the cable in the event of fire.

.....
..

2 x 1.5 RE/1.5

12.1000

3 x 1.5 RE/1.5
4 x 1.5 RE/1.5

4000 Veff

Biegeradius:

12 x of cable

Core identification:

coloured (HD 308 S2)

(EN 50265-2-1,
IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2,
IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A,
EN 50266-2-2,
DIN VDE 0472-804)
minimum smoke emission
(EN 50268-2, IEC 61034)
Test certificate:

Cert

Outer
diameter
(mm) ca.

Test voltage:

Fire properties:
flame retardant

Construction:
1 Copper conductor, round solid (RE), round stranded (RM)
resp. sector-shaped stranded (SM)
2 Core insulation (XLPE)
3 Inner covering (halogen-free polymer compound)
4 Concentric screen (bare copper wires) and counter helix
(copper tape)
5 Sheath (halogen-free polymere compound, black)

Max. conductor
resistance
/km)
(

0.6/1 kV

Temperature range:
laying temperature:
min. 5 C
operating temperature: fixed 40 C to +80 C
in motion 5 C to +50 C
conductor temperature: max. +90 C
short-circuit
temperature:
max. +250 C/5 s

Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Rated voltage:

.
..

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

14.0

54

240

500 T, 1000 T

12.1000

14.5

73

250

500 T, 1000 T

12.1000

15.5

88

300

500 T, 1000 T

2 x 2.5 RE/2.5

7.4100

15.0

83

280

500 T, 1000 T

3 x 2.5 RE/2.5

7.4100

15.5

113

320

500 T, 1000 T

N2XCH

4 x 2.5 RE/2.5

7.4100

16.5

138

380

500 T, 1000 T

2 x 4 RE/4

4.6100

14.0

128

320

500 T, 1000 T

3 x 4 RE/4

4.6100

16.0

168

400

500 T, 1000 T

4 x 4 RE/4

4.6100

17.5

208

480

500 T, 1000 T

2 x 6 RE/6

3.0800

15.0

190

410

500 T, 1000 T

3 x 6 RE/6

3.0800

18.0

250

500

500 T, 1000 T

4 x 6 RE/6

3.0800

19.0

309

600

500 T, 1000 T

2 x 10 RE/10

1.8300

17.0

325

550

500 T, 1000 T

Page 146

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

N2XCH
Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

N2XCH
3 x 10 RE/10

1.8300

20.0

425

750

500 T, 1000 T

4 x 10 RE/10

1.8300

21.5

525

800

500 T, 1000 T

2 x 16 RE/16

1.1500

19.0

509

780

500 T, 1000 T

3 x 16 RE/16

1.1500

22.5

670

1,000

500 T, 1000 T

4 x 16 RE/16

1.1500

24.5

829

1,200

500 T, 1000 T

3 x 25 RM/25

0.7270

25.0

1,045

1,430

500 T, 1000 T

4 x 25 RM/16

0.7270

29.0

1,190

1,800

500 T, 1000 T

3 x 35 RM/35

0.5240

29.0

1,460

1,900

500 T, 1000 T

4 x 35 SM/16

0.5240

30.0

1,590

2,100

500 T, 1000 T

3 x 50 RM/50

0.3870

32.0

2,083

2,200

500 T, 1000 T

4 x 50 SM/25

0.3870

32.5

2,295

2,800

500 T, 1000 T

3 x 70 RM/70

0.2680

36.0

2,913

3,050

500 T, 1000 T

4 x 70 SM/35

0.2680

38.0

3,210

3,800

500 T, 1000 T

3 x 95 RM/95

0.1930

41.0

3,949

4,200

500 T, 1000 T

4 x 95 SM/50

0.1930

43.5

4,383

5,100

500 T, 1000 T

3 x 120 RM/120

0.1530

45.0

4,985

5,200

500 T, 1000 T

4 x 120 SM/70

0.1530

47.5

5,613

6,300

500 T, 1000 T

3 x 150 RM/70

0.1240

48.0

5,313

5,450

500 T, 1000 T

4 x 150 SM/70

0.1240

53.0

6,813

7,500

500 T

3 x 185 RM/95

0.0991

53.0

6,649

6,800

500 T

4 x 185 SM/95

0.0991

55.0

8,499

8,900

500 T

3 x 240 RM/120

0.0754

60.0

8,585

8,900

500 T

4 x 240 SM/120

0.0754

61.0

10,985

11,200

500 T

7 x 1.5 RE/2.5

12.1000

15.0

139

350

500 T, 1000 T

10 x 1.5 RE/2.5

12.1000

17.0

183

480

500 T, 1000 T

12 x 1.5 RE/2.5

12.1000

20.5

214

550

500 T, 1000 T

16 x 1.5 RE/4

12.1000

21.0

288

680

500 T, 1000 T

21 x 1.5 RE/6

12.1000

22.0

384

770

500 T, 1000 T

24 x 1.5 RE/6

12.1000

24.0

430

850

500 T, 1000 T

30 x 1.5 RE/6

12.1000

26.0

520

1,000

500 T, 1000 T

7 x 2.5 RE/2.5

7.4100

16.0

208

440

500 T, 1000 T

10 x 2.5 RE/4

7.4100

19.0

298

600

500 T, 1000 T

12 x 2.5 RE/4

7.4100

22.0

348

750

500 T, 1000 T

16 x 2.5 RE/6

7.4100

23.0

470

850

500 T, 1000 T

21 x 2.5 RE/6

7.4100

25.0

595

1,090

500 T, 1000 T

24 x 2.5 RE/10

7.4100

26.0

725

1,180

500 T, 1000 T

30 x 2.5 RE/10

7.4100

29.0

875

1,500

500 T, 1000 T

7 x 4 RE/4

4.6100

20.0

333

610

500 T, 1000 T

7 x 6 RE/6

3.0800

21.5

495

850

500 T, 1000 T

12 x 6 RE/6

3.0800

22.0

795

905

500 T, 1000 T

Subject to technical changes.

Page 147

10

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

SKW | PRAKAB | Products

NHXCH FE180/E30, (N)HXCH FE180/E30


Power cables, with insulation integrity FE180 and functional integrity E30, screened
Standard: DIN VDE 0266 (NHXCH),
resp. adapted to DIN VDE 0266 ((N)HXCH)
Usage:
For fixed installation in interior premises and in the open air and for
direct burial in cable ducts and conduit. Since they are free from halogens and exhibit enhanced fire performance, these cables are used
in those applications where in the event of fire, the negative effects
on concentrations of people and valuable material goods must be
minimised.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
min. 5 C
operating temperature: fixed 40 C to +80 C
in motion 5 C to +50 C
conductor temperature: max. +90 C
short-circuit
temperature:
max. +250 C/5 s
Bending radius (min.): 12 x of cable
Core identification:

Fire properties:
flame retardant
(EN 50265-2-1, IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2,
IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A,
EN 50266-2-2,
DIN VDE 0472-804)
minimum smoke emission
(EN 50268-2, I
EC 61034)
insulation integrity FE180 (IEC 60331,
DIN VDE 0472-814)
functional integrity E30 (DIN VDE 4102-12)

Construction:
1 Copper conductor, round solid (RE) or round stranded (RM)
2 Flame protection by conductor taping (mica tape, only for NHXCH)
or by a ceramising halogen-free polymer compound
3 Core insulation (halogen-free polymer compound, cross linked)
4 Taping (halogen-free glass fabric tape)
5 Inner covering (halogen-free polymer compound)
6 Concentric screen (bare copper wires) and counter helix
(copper tape)
7 Sheath (halogen-free polyolefin compound, orange)

Test certificate:

Cert
.....
..

Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

2 x 1.5 RE/1.5

12.1000

14.0

3 x 1.5 RE/1.5

12.1000

4 x 1.5 RE/1.5

12.1000

2 x 2.5 RE/2.5

7.4100

3 x 2.5 RE/2.5

7.4100

4 x 2.5 RE/2.5

coloured (HD 308 S2)

.
..

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

54

240

500 T, 1000 T

15.0

73

260

500 T, 1000 T

17.0

88

310

500 T, 1000 T

15.0

83

290

500 T, 1000 T

16.0

113

330

500 T, 1000 T

7.4100

18.0

138

380

500 T, 1000 T

3 x 4 RE/4

4.6100

17.0

168

420

500 T, 1000 T

4 x 4 RE/4

4.6100

20.0

208

500

500 T, 1000 T

3 x 6 RE/6

3.0800

19.0

250

540

500 T, 1000 T

4 x 6 RE/6

3.0800

21.0

309

640

500 T, 1000 T

3 x 10 RE/10

1.8300

21.0

425

760

500 T, 1000 T

NHXCH FE180/E30, (N)HXCH FE180/E30

Page 148

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

NHXCH FE180/E30, (N)HXCH FE180/E30


Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

NHXCH FE180/E30, (N)HXCH FE180/E30


4 x 10 RE/10

1.8300

23.0

525

900

500 T, 1000 T

3 x 16 RE/16

1.1500

23.0

670

1,100

500 T, 1000 T

4 x 16 RE/16

1.1500

26.0

829

1,300

500 T, 1000 T

3 x 25 RM/25

0.7270

28.0

1,045

1,650

500 T, 1000 T

4 x 25 RM/16

0.7270

31.0

1,190

1,900

500 T, 1000 T

3 x 35 RM/35

0.5240

30.0

1,460

2,200

500 T, 1000 T

4 x 35 RM/16

0.5240

33.0

1,590

2,400

500 T, 1000 T

3 x 50 RM/50

0.3870

34.0

2,083

2,900

500 T, 1000 T

4 x 50 RM/25

0.3870

38.0

2,295

3,400

500 T, 1000 T

3 x 70 RM/70

0.2680

39.0

2,913

4,000

500 T, 1000 T

4 x 70 RM/35

0.2680

42.0

3,210

4,500

500 T, 1000 T

3 x 95 RM/95

0.1930

44.0

3,949

5,300

500 T, 1000 T

4 x 95 RM/50

0.1930

49.0

4,383

6,100

500 T, 1000 T

3 x120 RM/70

0.1530

47.0

4,985

6,000

500 T, 1000 T

4 x 120 RM/70

0.1530

53.0

5,613

7,600

500 T

3 x 150 RM/70

0.1240

52.0

5,313

7,300

500 T

4 x 150 RM/70

0.1240

60.0

6,813

8,700

500 T

3 x 185 RM/95

0.0991

55.0

6,649

7,900

500 T

4 x 185 RM/95

0.0991

63.0

8,499

8,900

500 T

3 x 240 RM/120

0.0754

62.0

8,585

9,000

500 T

4 x 240 RM/120

0.0754

66.0

10,985

11,500

500 T

7 x 1.5 RE/2.5

12.1000

19.0

139

420

500 T, 1000 T

10 x 1.5 RE/2.5

12.1000

23.0

183

560

500 T, 1000 T

12 x 1.5 RE/2.5

12.1000

24.0

214

620

500 T, 1000 T

14 x 1.5 RE/2.5

12.1000

25.0

248

700

500 T, 1000 T

19 x 1.5 RE/4

12.1000

28.0

338

950

500 T, 1000 T

24 x 1.5 RE/6

12.1000

32.0

430

1,150

500 T, 1000 T

30 x 1.5 RE/6

12.1000

34.0

520

1,350

500 T, 1000 T

7 x 2.5 RE/2.5

7.4100

21.0

208

540

500 T, 1000 T

10 x 2.5 RE/4

7.4100

24.0

298

760

500 T, 1000 T

12 x 2.5 RE/4

7.4100

25.0

348

850

500 T, 1000 T

14 x 2.5 RE/6

7.4100

27.0

470

1,100

500 T, 1000 T

19 x 2.5 RE/6

7.4100

30.0

595

1,350

500 T, 1000 T

24 x 2.5 RE/10

7.4100

35.0

725

1,500

500 T, 1000 T

30 x 2.5 RE/10

7.4100

37.0

875

1,800

500 T, 1000 T

Subject to technical changes.

Page 149

10

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

SKW | PRAKAB | Products

NHXCH FE180/E90
Power cables, with insulation integrity FE180 and functional integrity E90, screened
Standard: DIN VDE 0266
Usage:
For fixed installation in interior premises and in the open air and for
direct burial in cable ducts and conduit. Since they are free from halogens and exhibit enhanced fire performance, these cables are used
in those applications where in the event of fire, the negative effects
on concentrations of people and valuable material goods must be
minimised.

Rated voltage:

0.6/1 kV

Test voltage:

4000 Veff

Temperature range:
laying temperature:
min. 5 C
operating temperature: fixed 40 C to +80 C
in motion 5 C to +50 C
conductor temperature: max. +90 C
short-circuit
temperature:
max. +250 C/5 s
Bending radius (min.): 12 x of cable
Core identification:

coloured (HD 308 S2)

1
Fire properties:
flame retardant
(EN 50265-2-1, IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2,
IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A,
EN 50266-2-2,
DIN VDE 0472-804)
minimum smoke emission
(EN 50268-2,
IEC 61034)
insulation integrity FE180 (IEC 60331,
DIN VDE 0472-814)
functional integrity E90 (DIN VDE 4102-12)

Construction:
1 Copper conductor, round solid (RE) or round stranded (RM)
2 Flame protection by conductor taping (mica tape)
3 Core insulation (halogen-free polymer compound, cross linked)
4 Taping (halogen-free glass fabric tape)
5 Inner covering (halogen-free polymer compound)
6 Concentric screen (bare copper wires) and counter helix (copper tape)
7 Sheath (halogen-free polyolefin compound, orange)

Test certificate:

Cert
.....
..

Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

2 x 1.5 RE/1.5

12.1000

14.0

3 x 1.5 RE/1.5

12.1000

4 x 1.5 RE/1.5

12.1000

2 x 2.5 RE/2.5

7.4100

3 x 2.5 RE/2.5

7.4100

4 x 2.5 RE/2.5

.
..

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

54

240

500 T, 1000 T

15.0

73

260

500 T, 1000 T

17.0

88

310

500 T, 1000 T

15.0

83

290

500 T, 1000 T

16.0

113

330

500 T, 1000 T

7.4100

18.0

138

380

500 T, 1000 T

3 x 4 RE/4

4.6100

17.0

168

420

500 T, 1000 T

4 x 4 RE/4

4.6100

20.0

208

500

500 T, 1000 T

3 x 6 RE/6

3.0800

19.0

250

540

500 T, 1000 T

4 x 6 RE/6

3.0800

21.0

309

640

500 T, 1000 T

3 x 10 RE/10

1.8300

21.0

425

760

500 T, 1000 T

NHXCH FE180/E90

Page 150

SKW | PRAKAB | Products

- >> HALOGEN-FREE ENERGY CABLES 0.6/1 kV

NHXCH FE180/E90
Number of cores x
nominal cross
section/cross
section of screen
(mm2)

Max. conductor
resistance
/km)
(

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

NHXCH FE180/E90
4 x 10 RE/10

1.8300

23.0

525

900

500 T, 1000 T

3 x 16 RM/16

1.1500

23.0

670

1,100

500 T, 1000 T

4 x 16 RM/16

1.1500

26.0

829

1,300

500 T, 1000 T

3 x 25 RM/25

0.7270

28.0

1,045

1,650

500 T, 1000 T

4 x 25 RM/16

0.7270

31.0

1,190

1,900

500 T, 1000 T

3 x 35 RM/35

0.5240

30.0

1,460

2,200

500 T, 1000 T

4 x 35 RM/16

0.5240

33.0

1,590

2,400

500 T, 1000 T

3 x 50 RM/50

0.3870

34.0

2,083

2,900

500 T, 1000 T

4 x 50 RM/25

0.3870

38.0

2,295

3,400

500 T, 1000 T

3 x 70 RM/70

0.2680

39.0

2,913

4,000

500 T, 1000 T

4 x 70 RM/35

0.2680

42.0

3,210

4,500

500 T, 1000 T

3 x 95 RM/95

0.1930

44.0

3,949

4,800

500 T, 1000 T

4 x 95 RM/50

0.1930

49.0

4,383

6,100

500 T, 1000 T

3 x 120 RM/120

0.1530

47.0

4,985

6,000

500 T, 1000 T

4 x 120 RM/70

0.1530

53.0

5,613

7,600

500 T

3 x 150 RM/70

0.1240

52.0

5,313

7,300

500 T

4 x 150 RM/70

0.1240

55.0

6,813

8,500

500 T

3 x 185 RM/95

0.0991

55.0

6,649

7,900

500 T

4 x 185 RM/95

0.0991

59.0

8,499

8,900

500 T

3 x 240 RM/120

0.0754

59.0

8,585

9,000

500 T

4 x 240 RM/120

0.0754

64.0

10,985

11,500

500 T

7 x 1.5 RE/2.5

12.1000

19.0

139

420

500 T, 1000 T

10 x 1.5 RE/2.5

12.1000

23.0

183

560

500 T, 1000 T

12 x 1.5 RE/2.5

12.1000

24.0

214

620

500 T, 1000 T

14 x 1.5 RE/2.5

12.1000

25.0

248

700

500 T, 1000 T

19 x 1.5 RE/4

12.1000

28.0

338

950

500 T, 1000 T

24 x 1.5 RE/6

12.1000

32.0

430

1,150

500 T, 1000 T

30 x 1.5 RE/6

12.1000

34.0

520

1,350

500 T, 1000 T

7 x 2.5 RE/2.5

7.4100

21.0

208

540

500 T, 1000 T

10 x 2.5 RE/4

7.4100

24.0

298

760

500 T, 1000 T

12 x 2.5 RE/4

7.4100

25.0

348

850

500 T, 1000 T

14 x 2.5 RE/4

7.4100

27.0

398

950

500 T, 1000 T

19 x 2.5 RE/6

7.4100

30.0

550

1,200

500 T, 1000 T

24 x 2.5 RE/10

7.4100

35.0

725

1,550

500 T, 1000 T

30 x 2.5 RE/10

7.4100

39.0

875

1,900

500 T, 1000 T

Subject to technical changes.

Page 151

10

SKW | PRAKAB | Products

- >> HALOGEN-FREE TELECOMMUNICATIONS CABLES

JH(St)H...Bd
Installation cable, screened
Standard: DIN VDE 0815
Usage:
For use in telecommunications installations. Suitable for interior
applications in dry and damp premises, as well on or under plaster.
Not suitable for power installation purposes and for direct burial.
Since they are free from halogens and exhibit enhanced fire
performance, these cables are used in those applications where in
the event of fire, the negative effects on concentrations of people
and valuable material goods must be minimised.

Rated voltage:

max. 300 Vss

Test voltage:

core/core 800 Veff


core/screen 800 Veff

Temperature range:
laying temperature:
min. 5 C
operating temperature: fixed 30 C to +70 C
in motion 5 C to +50 C
conductor temperature: +70 C
Bending radius (min.): 7.5 x of cable

Core identification:

coloured (VDE 0815;


BdSi, BdZ)

Fire properties:
flame retardant
(EN 50265-2-1, IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2,
IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A,
EN 50266-2-2,
DIN VDE 0472-804)
minimum smoke emission
(EN 50268-2,
IEC 61034)

Construction:
1 Copper conductor, round solid (RE)
2 Core insulation (halogen-free polymer compound), conductors pair
stranded, pairs stranded into groups
3 Inner covering (halogen-free plastic tape)
4 Screen (plastic laminated aluminium tape with drain wire)
5 Sheath (halogen-free polymere compound, grey)

Test certificate:

Cert
.....
..

.
..

VDE Germany

.. .. ...
Sz JZD .
. . ..
.

Electrical parameters
Conductor diameter

(mm)

0.6

0.8

(/km)

130

73.2

Insulation resistance, min.

(M.km)

100

100

Mutual capacitance, max. at 800 Hz (until 4 pairs)

(nF/km)

144

144

Loop resistance, max.

Mutual capacitance, max. at 800 Hz

(nF/km)

120

120

Capacitance unbalance K1, max. at 800 Hz (100 % of values)

(pF/100 m)

500

500

Capacitance unbalance K1, max. at 800 Hz (80 % of values)

(pF/100 m)

300

300

Capacitance unbalance K9-K12, max. at 800 Hz (100 % of values)

(pF/100 m)

300

300

Capacitance unbalance K9-K12, max. at 800 Hz (80 % of values)

(pF/100 m)

100

100

Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

2 x 2 x 0.6

6.5

13

55

500 T, 1000 T

4 x 2 x 0.6

9.0

6 x 2 x 0.6

9.5

24

88

500 T, 1000 T

36

104

500 T, 1000 T

JH(St)H...Bd

Page 152

SKW | PRAKAB | Products

- >> HALOGEN-FREE TELECOMMUNICATIONS CABLES

JH(St)H...Bd
Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

JH(St)H...Bd
10 x 2 x 0.6

11.0

59

143

500 T, 1000 T

20 x 2 x 0.6

13.0

116

216

500 T, 1000 T

30 x 2 x 0.6

15.5

172

312

500 T, 1000 T

40 x 2 x 0.6

17.0

228

378

500 T, 1000 T

50 x 2 x 0.6

19.0

285

474

500 T, 1000 T

60 x 2 x 0.6

21.0

342

571

500 T, 1000 T

80 x 2 x 0.6

24.0

455

680

500 T, 1000 T

100 x 2 x 0.6

26.5

568

887

500 T, 1000 T

2 x 2 x 0.8

7.5

21

70

500 T, 1000 T

4 x 2 x 0.8

11.0

41

124

500 T, 1000 T

6 x 2 x 0.8

11.5

62

152

500 T, 1000 T

10 x 2 x 0.8

13.5

103

214

500 T, 1000 T

20 x 2 x 0.8

16.0

203

336

500 T, 1000 T

30 x 2 x 0.8

19.5

304

490

500 T, 1000 T

40 x 2 x 0.8

22.0

404

625

500 T, 1000 T

50 x 2 x 0.8

25.0

505

788

500 T, 1000 T

60 x 2 x 08

27.0

606

924

500 T, 1000 T

80 x 2 x 0.8

30.5

807

1,218

500 T, 1000 T

100 x 2 x 0.8

34.0

1,008

1,500

500 T, 1000 T

Subject to technical changes.

11

Page 153

- >> HALOGEN-FREE TELECOMMUNICATIONS CABLES

SKW | PRAKAB | Products

JEH(St)H...Bd FE180/E30 / JEH(St)H...Bd FE180/E90


Control cable for industrial electronics
Standard: adapted to DIN VDE 0815
Usage:
For use in control and regulating systems and related installations.
Suitable for interior applications in dry and damp premises, as well
on or under plaster. Not suitable for power installation purposes and
for direct burial. Since they are free from halogens and exhibit
enhanced fire performance, these cables are used in those
applications where in the event of fire, the negative effects on
concentrations of people and valuable material goods must be
minimised.

Rated voltage:

max. 225 Vss

Test voltage:

core/core 500 Veff


core/screen 2000 Veff

Temperature range:
laying temperature:
min. 5 C
operating temperature: fixed 30 C to +70 C
in motion 5 C to +50 C
conductor temperature: +70 C
Bending radius (min.): 7.5 x of wire
Core identification:

3,4

coloured (VDE 0815;


BdSi, BdZ)

Fire properties:
flame retardant
(EN 50265-2-1, IEC 60332-1)
halogen-free, no corrosive combustion gases
(EN 50267-2-2,
IEC 60754-2)
reduced fire propagation (IEC 60332-3 Cat. A,
EN 50266-2-2,
DIN VDE 0472-804)
minimum smoke emission
(EN 50268-2,
IEC 61034)
insulation integrity FE180 (IEC 60331,
DIN VDE 0472-814)
functional integrity E30 resp. E90
(DIN VDE 4102-12)

Construction:
1 Copper conductor, round solid (RE) with conductor taping (mica
tape, only E90)
2 Core insulation (halogen-free polymer compound), conductors pair
stranded, pairs stranded into groups
3 Inner covering (halogen-free plastic tape)
4 Inner covering (halogen-free glass fabric tape)
5 Screen (plastic laminated aluminium tape with drain wire)
6 Sheath (halogen-free polymere compound, orange)

Test certificate:

Cert
.....
..

VDE Germany

.. .. ...
.
.
.. . Sz JZD .
. . .

Electrical parameters
Conductor diameter
Loop resistance, max.
Insulation resistance, min.

(mm)

0.8

(/km)

73.2

(M.km)

100

Mutual capacitan,ce, max. at 800 Hz (until 4 pairs)

(nF/km)

144

Mutual capacitance, max. at 800 Hz

(nF/km)

120

Capacitance unbalance K1, max. at 800 Hz (100 % of values)

(pF/100 m)

400

Capacitance unbalance K1, max. at 800 Hz (80 % of values)

(pF/100 m)

200

Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

2 x 2 x 0.8

7.5

4 x 2 x 0.8
8 x 2 x 0.8

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

25

65

500 T, 1000 T

9.5

45

104

500 T, 1000 T

11.5

85

165

500 T, 1000 T

JEH(St)H...Bd FE180/E30

Page 154

SKW | PRAKAB | Products

- >> HALOGEN-FREE TELECOMMUNICATIONS CABLES

JEH(St)H...Bd FE180/E30 / JEH(St)H...Bd FE180/E90


Number of pairs x
nominal diameter
(mm)

Outer
diameter
(mm) ca.

Metal
weight
(kg/km)

Total
weight
(kg/km) ca.

Standard lenghts/
packing
(m)

JEH(St)H...Bd FE180/E30
12 x 2 x 0.8

13.0

126

235

500 T, 1000 T

16 x 2 x 0.8

15.0

166

300

500 T, 1000 T

20 x 2 x 0.8

16.5

206

361

500 T, 1000 T

JEH(St)H...Bd FE180/E90
2 x 2 x 0.8

8.5

25

83

500 T, 1000 T

4 x 2 x 0.8

11.5

45

138

500 T, 1000 T

8 x 2 x 0.8

15.0

85

243

500 T, 1000 T

12 x 2 x 0.8

18.5

126

351

500 T, 1000 T

16 x 2 x 0.8

20.5

166

441

500 T, 1000 T

20 x 2 x 0.8

24.0

206

557

500 T, 1000 T

Subject to technical changes.

11

Page 155

SKW | PRAKAB | Products

- >> C O N T E N T S

>> -

General technical information

1.
2.
3.

Basic design elements for insulated wires and cables


Common insulation and jacketing materials (polymers) and their use
Type codes

157

3.1

Type codes for harmonised insulated wires

159

3.2

Type codes for power cables

160

3.3

Type codes for telecommunications cables

161

3.4

Terms for cables relating to their behaviour in case of fire

162

4.

Core identification

163

4.1

Colour codes for insulated wires and power cables

163

4.2

Colour codes for 0,6/1 kV power cables according to SEV

163

4.3

Colour codes for 0,6/1 kV power cables according to MSZ

164

4.4

Colour code for power cables according to HD 603

164

158
159

4.4.1 Colour code for power cables according to HD 603.3E, HD 603.5B2

164

4.4.2 Colour code for power cables according to HD 603.5M

164

4.4.3 Colour code for power cables according to HD 603.5D

164

4.4.4 Colour code for power cables according to HD 603.3J, HD 603.5J

165

4.4.5 Colour code for power cables according to HD 603.3L

165

4.5

Colour code for Installation Cables JE-LiYCY and JE-Y(St)Y ... Bd according to VDE 0815

165

4.6

Colour code for telecommunications cables according to VDE 0815

166

4.7

Colour code for telecommunications cables according to VE regulations or TA specification

166

5.

Permissible installation conditions

167

5.1

Permissible minimum bending radius

167

5.2

Permissible installation temperatures

168

5.3

Permissible tensile stress for low- and medium-voltage cables

168

6.

Current rating and voltage drop for 1-30 kV cables

169

7.

Packaging

170

7.1

Typ of packaging

170

7.2

Drum capacity

170

7.3

Allocation of drums

171

7.4

Standard delivery drums

172

Page 156

SKW | PRAKAB | Products

General technical information


1. Basic Design Elements for insulated Wires and Cables
Conductor
Consists of one or more metal wires and is used for transportation of electric current.
Round, solid (RE)
For small and medium diameter or cross-sections, made of copper (bare or tinned) up to 16 mm2 and of
aluminium up to 35 mm2. Used in single- and multi-core cables and wires for fixed installation.
Round, stranded (RM)
For medium and large cross-sections of copper-conductors from 6 mm2 and aluminium conductors from
25 mm2. Used in single- and multi-core cables and wires for fixed installation.
Round, stranded, compacted (RM)
For particularly compact conductors of medium and large cross-section made of copper from 6 mm2 and
aluminium from 25 mm2. For use in single- and multi-core cables and wires for fixed installation.
Fine or superfine-wire (F)
For all cross-sections of copper-conductors (bare or tinned). Used for flexible cables.

Sector-shaped, solid (SE)


For medium and large cross-sections of aluminium conductors up to 185 mm2. Used for 3-, 31/2- and 4-core
cables.

Sector-shaped, stranded (SM)


For medium and large cross-sections of copper and aluminium conductors from 35 mm2. Used for 3-, 31/2- and
4-core cables.

Core insulation
Covers the conductor and is used for electrical separation from the surroundings. Mainly made of extruded polymers but also of
paper, glass or minerals, varnish etc or a combination of several of these materials. Conductor and insulation together form the
core.

Inner Covering, Taping


Covers the stranded core consisting of several or many cores and is used for filling the interstices between the strandingelements, maintaining a round shape of the cable. The inner covering has mostly no electrical function and consists usually either
of extruded polymers, of one or more layers of tape or a combination of those elements.

Screen
Prevents electrical influences (electric fields) from reaching elements within the screen or electric fields generated by these
elements from penetrating outside by conductance. Consists of metallic tapes (e.g. copper or aluminium), laminated metallic
tapes, wires, wire braids or a combination of these elements.

Armouring
Usually arranged over the jacket, the armouring provides mechanical reinforcement of the cable jacket. The armouring protects
the interior of the cable from damage which may arise from radial forces (e.g. running over by vehicles or pressure of stones in
the cable bed etc.) Under certain circumstances, the armouring can take over or assist the electrical function of the screen. Tape
as well as round or flat wire made of galvanised steel or aluminium is usually used as armouring material. If protection against
chewing damage by rodents is merely required, thin, bare steel tapes are usually used. Non-metallic designs as protection
against chewing damage by rodents or termites are provided by reinforcing the jacket with HDPE and PP.

Sheath, Outer Covering


Functions as the outermost cover of a cable or insulated wire and is used as mechanical protection, as protection against water
penetration and as protection against chemical influences. Mostly made of extruded polymers, but also of metal (lead,
aluminium), impregnated fabric tapes etc.

Page 157

SKW | PRAKAB | Products

General technical information


2. Common Insulation and Jacketing Materials (Polymers) and their use
Polymers
Thermoplastics
Non-cross-linked plastics which undergo reversible plastic deformation at higher temperatures, i.e. which do not harden after cooling and remelting.

Designs

Examples of usage

Polyvinyl chloride PVC

Cables and insulated wires for fixed installation and flexible


cables, low-voltage cables for utility networks

Thermoplastic polyethylene PE

Low-voltage cables for utility networks subject to fairly high


mechanical stressing, insulated overhead lines

Polypropylene PP

Environmentally friendly clad leads

Fluorkunststoffe ETFE, FEP

Cables for fixed installation under particularly unfavourable


ambient conditions, cables in turbines

Polyamide PA
Cross-linked thermoplastics
Thermoplastics which are no longer deformable at higher temperatures and exhibit certain thermoelastic properties at
this temperature and which are re-established after cooling and re-melting.

Cross-linked polyethylene PE
(XLPE)

Medium- and high-voltage cables, insulated overhead lines

Cross-linked polyvinyl chloride


VPVC

Heat-resistant insulated wires, e.g. for connecting irons

Thermoplastic elastomers
Blends of polyolefins and rubber having
amorphous and crystalline regions
which undergo reversible plastic deformation at higher temperatures and exhibit rubber-elastic properties without
cross-linking at usage temperatures.

Thermoplastic polyurethane elastomer TPE-U

Elastomers
Cross-linked rubber-like polymers which
exhibit rubber-elastic properties at usage temperatures and are no longer plastically deformable at higher temperature.

Control cables in cable drag chains

Thermoplastic polyester elastomer


TPE-E

Cables for particular thermal and mechanical stresses

Thermoplastic polyolefin elastomer


TPE-O

Cables for particular thermal and mechanical stresses

Ethylene propylene rubber (EPR):


EPDM, EPM

Flexible cables for low- and medium voltage, low- and medium-voltage cables

Silicone rubber SiR

Heat-resistant insulated wires for temperatures up to 180 C


(up to 250 C for a short time)

Natural rubber NR

Duroplastics
Cross-linked shape-stable plastics produced from curable resins.

Polychloroprene CR

Jacketing material e.g. for flexible cables

Ethylene vinyl acetate (EVA)

Heat-resistant insulated wires for temperatures up to 110 C

Polyurethane (PUR)

Casting resins for cable fittings

Epoxy resin EP

Special compounds

Page 158

Flame-retardant, halogen-free polymer compounds, non-cross-linked

Flame-retardant, halogen-free safety cable for protecting


high concentrations of people and material goods

Flame-retardant, halogen-free polymer compounds, cross-linked

Flame-retardant, halogen-free safety cable for protecting


high concentrations of people and material goods

SKW | PRAKAB | Products

General technical information


3.

Type Codes

3.1 Type codes for Harmonised insulated wires

Code for standard

Conductor cross-section

Harmonised standard

Recognised national type

A
Protective conductor

Rated voltage U0/U


100/100 V

01

300/300 V

03

300/500 V

05

450/750 V

07

0.6/1 kV

Without protective conductor

With protective conductor

Number of cores

Conductor design

Insulation material

Solid wire

Stranded wire

PVC

Natural and synthetic


rubber

Fine wire
(for fixed installation)

Silicone rubber

Fine wire
(for flexible cables)

XLPE

Super-fine wire
(for flexible cables)

Flame-retardant, halogen-free
polymer compounds, cross-linked

Flame-retardant halogen-free
compounds, non-cross-linked

Tinsel wire

flexible
(for welding cables)

Super-flexible
(for welding cables)

Z1

Jacketing material
PVC

Natural and synthetic


rubber

Chloroprene rubber

Chloroprene rubber
(special compound)

N2

Glass fibre braid

Textile braid

Textile braid, mass


impregnated, flame retardant

T2

Special design
Flat, separable

Flat, non-separable

H2

Central element

D5

Example: H03VV-F 3G1.5


Light PVC flexible cable,
fine-wire 3 x 1.5 mm2

Page 159

SKW | PRAKAB | Products

General technical information


3.2 Type Codes for Power Cables
Design- / Code Element

Standard

Cables according to Halogen-free power


TP Prakab
cables according to
TP Prakab

Cables according to
DIN VDE and VE

TP Prakab 01/03

TP Prakab 02/99
and 02/04

DIN VDE 0265, 0266,


0271, 0272, 0273

VE K23, K24,
K25, K26

Type
Standard type
Power cable

N
-

E-

Special design

Rated voltage U0/U


300/500 V
0.6/1 kV

05
1

05
1

Conductor
Cu
Al
Tinned conductor
Conductor covered (taping)

C
A
-

C
A
no code

no code
A
V
no code

no code
A

Insulation
PVC
PE
VPE
halogen-free polymer compounds, non cross-linked
halogen-free polymer compounds, cross-linked

Y
-

X
H
-

Y
2Y
2X
HX

Y
2Y
2X
NY
NG, 3G

Special structural features


Cable, unscreened
Cable, flat with web
Cable, aluminium tape screened
Cable, flexible
Cable, flexible screened

K
M
-

K
F
T
TF

Screen, concentric conductor


Concentric conductor (Cu, conventionally stranded)
Concentric conductor (Cu, wave-form)
Cu screen
Cu screen (longitudinally water-proof)
Individual Cu screen over each core

C
F
-

C
CW
S
SE

C
C
C
CJ
CE

Sheath, inner covering


Pb
PVC
PE
halogen-free polymer compounds, non cross-linked
halogen-free polymer compounds, cross-linked

Y
2Y
-

K
Y
2Y
HX

M
Y
2Y
NY
NG

Armouring/cable structure
Steel tape
Steel flat wire
Steel round wire
Steel tape (counter helix)
Cable, flat
Cable, self-supporting

P
D
Lo
Z

D1
D
-

B
F
R
G
-

B
F
R
G
-

Outer covering
PVC
PE
halogen-free polymer compounds, non cross-linked

Y
2Y
-

Y
2Y
H

Y
2Y
-

Protective conductor
With protective conductor
Without protective conductor

-J
-O

-J
-O

-J
-O

-J
-O

-R
-V ...
-

FE ...
E ..

FRH
FE ...
E ..

Insulation / Functional Integrity


Halogen-free, without insulation/functional integrity
Halogen-free, with insulation integrity ...minutes
Halogen-free, with functional integrity ...minutes

The complete cable code consists of (according to each standard different composition and structur):
- Code for the type
- Code for the conductor design
- Code for core identification
- Code(s) for the cable design
- If necessary after a slash: Nominal cross- Code for rated voltage
- Number of cores x nominal conductor
section of the screen or concentric
- Code for additional information
cross-section
conductor
- Code(s) for core identification

Example: NHXCH 4 x 2.5 RE / 2.5 0.6/1 kV E30, 1-CXKH-V180 4B x 25 RM


Page 160

SKW | PRAKAB | Products

General technical information


3.3 Type Codes for Telecommunication Cables
Design- /Code Element

Telecom. cable
according to
TP Prakab

Telecom. cable
according to
DIN VDE

Telecom. cable
according to VE

Cable acc. to
TA specification

Type
Telecommunication cable
Outdoor cable
Outdoor cable with protection against interference
Installation cable
Installation cable for industrial electronics
Switchboard cable

T
S
-

AAJJJES-

F-

FFI-

Special design

Conductor
Cu
Tinned conductor
Insulation
Paper
PVC
PE
XLPE
Foam-skin PE
Foam-skin PE, with skin from solid PE
halogen-free polymer compounds, non cross-linked

C
-

no code
-

no code
V

no code
V

Y
E
X
EP
H

P
Y
2Y
02Y
02YS
H

P
Y
2Y
NY

P
Y
2Y
02Y
02YH
-

Design of core
No filling of cable cavities
Jelly filling of cable cavities

K
KP

Screen
Static screen, laminated Al-tape
Cu screen
Individual screen

F
-

(St)
C, K
-

A
C
E

A
C
E

Sheath, inner covering


Pb
Al-tape, taped
Al laminated sheath, longitudinallly applied
PVC
PE
halogen-free polymer compounds, non cross-linked

F
FL
Y
E
H

M
(L)2Y
Y
H

M
Y
2Y
NY

M
A2Y
Y
2Y
-

Armouring
Steel tape
Steel flat wire
Steel round wire
Steel tape (counter helix)
Steel wire braid
Al round wire

D
Z

b
Q
-

B
F
R
G
-

B
F
R
G
-

Outer covering
Mass-impregnated jute
PVC
PE

Y
E

c
Y
2Y

U
Y
2Y

U
Y
2Y

Strain-bearing element
Strain-bearing element, supporting element

Stranding elements
Pairs
Pairs, individually screened with metal tape
Star-quads
Star-quads in long distance cables
Star-quads in local cables
Multiple-twin quad cables
Stranded in layers
Stranded in groups

P
PiMF
St
St I
St III
DM
Lg
Bd

P
ST
DM
-

P
ST
DM
BD

-R
-V ...
-

FRH
FE ...
E ...

FRH
FE ...
E ...

Insulation / Functional integrity


Halogen-free, without insulation/functional integrity
Halogen-free, with insulation integrity ...minutes
Functional integrity ... minutes

The complete cable code consists of (according to each standard different composition and structur):
- Code for the type
- Number of elements x number of cores per
- Codes for the stranding elements and the
- Code(s) for the cable design
element x conductor diameter
kind of stranding
- Codes for additional information

Example: F2YA2Y 100 x 2 x 0.6, JE-H(St)H Bd FE 2 x 2 x 0.8 FE180/E30, TCEPKPFLE 50 x 4 x 0.8


Page 161

SKW | PRAKAB | Products

General technical information


3.4 Terms for Cables relating to their behaviour in case of fire
Halogen free, no corrosive combustion gases
Is the property of a cable to consist only of materials which generate none or only small quantities of corrosive gases in the case
of fire. These gases have the result that in the event of fire, material goods are damaged without the direct effect of the fire. For
freedom from halogens it is usually necessary to meet the requirements of the applicable standard, e.g. tests according to EN
50267, IEC 60754-2 or DIN VDE 0482-267. H is added to the code of these cables and if they are enhanced flame-retardant, the
symbol FRH is added.

Flame-retardant ("self-extinguishing")
Is the property of a cable to automatically extinguish itself within a certain time after ignition by using barely flammable materials.
For flame retardancy it is usually necessary to meet the requirements of the applicable standard, e.g. the single cable test
according to EN 50265, IEC 60332-1 or DIN VDE 0482-265. If these cables are also halogen-free, H is added to the code.

Enhanced flame-retardant ("reduced fire propagation")


Is the property of a cable to severely limit the spread of flames beyond the local source of ignition in the event of fire. For
enhanced flame retardancy it is usually necessary to meet the requirements of the applicable standard, e.g. the multi-cable test
according to IEC 60332-3 Cat. C or EN 50266-2-4. The symbol FR is added to the code for these cables. If they are also
halogen-free, FRH is added to the code.

Minimum smoke emission


Is the property of a cable to generate only a minimal amount of smoke in the case of fire. For minimal smoke production it is
usually necessary to meet the requirements of the applicable standard, e.g. testing according to EN 50268, IEC 61034 or DIN
VDE 0482-268. In these tests the reduction in the permeability of light in a standardised room is measured during combustion of
the cable.

Insulation integrity on exposure to flames (e.g. FE 180)


Is the property of a low-fire-spread halogen-free cable to retain the dielectric strength (insulation capability) without mechanical
stressing for a certain time in the event of fire. Thus, the insulation integrity of the individual cable is guaranteed for a certain time
in the event of fire, but an exact determination of the duration of complete functional efficiency to be predicted in the event of fire
is not necessarily given. For the insulation integrity it is usually necessary to meet the requirements of the applicable standard,
e.g. testing according to IEC 60331 or DIN VDE 0472-814. The symbol FE is added to the code for these cables as well as the
duration in minutes during which the dielectric strength is guaranteed on exposure to flames.

Functional integrity (e.g. E30, E90)


Is the property of a cable installation to retain its functional capability for a certain time in the event of fire. It is important that the
cable is not considered alone but the entire installation including the installation materials used (clamps, channels etc). For the
functional integrity it isusually necessary to meet the requirements of the applicable standard, e.g. testing according to
DIN/NORM 4102-12. The symbol E is added to the code for these cables as well as the duration in minutes for which the
functional integrity is guaranteed in the event of fire.

Page 162

SKW | PRAKAB | Products

General technical information


4. Core Identification
Cores in cables and insulated wires (except insulated overhead lines) are identified by the colour of the insulation and/or printed
colours (numbers, rings) or longitudinal colour stripes. The following colour abbreviation are used:
Colour

Abbreviation

Colour

Abbreviation

blue

bl

orange

or

brown

br

pink

ro

yellow

ge

red

rt

grey

gr

black

sw

green

gn

violet

vi

natural

nat

white

ws

In case of insulated overhead lines, the cores are identified by longitudinal ribs on the insulation surface.

4.1. Colour Codes for insulated wires and power cables


Colour codes taking HD 308 S2 (introduced in 2004) into account:
with gnge core

Number of cores

without gnge core


and other colours

1
2
3
4
5
6 or more

with printed numbers


other cores
with printed numbers

These rules are not valid for cables, which are exclusively used for internal wiring of electrical devices and control cabinets.

4.2 Colour code for power cables according to SEV


Core number
Core function

1
L

2
PE

2L

LN

3
LPE

3L

2LN

4
2PLE

LNPE

4L

3LN

5
3LPE 2NLPE

5L

3LNPE

Black
Red
White
Light blue
Yellow-green

Page 163

SKW | PRAKAB | Products

General technical information

4.3 Colour code for power cables according to MSZ 1167/4


Core number

-J with gnge core

-0 without gnge core

with concentric conductor

2
3
4
with printed numbers

5
with printed numbers

6 or more
other cores
with printed numbers

4.4 Colour code for power cables according to HD 603


4.4.1 Colour code for power cables according to HD 603.3E, HD 603.5B
Core number

Core colour
1)

4
1) Black core with white stripes

4.4.2 Colour code for power cables according to HD 603.5M


Core number

Core colour

4.4.3 Colour code for power cables according to HD 603.5D


Core number

Core colour
1)

4
1) Black core with white stripes

Page 164

with printed numbers

SKW | PRAKAB | Products

General technical information

4.4.4 Colour code for power cables according to HD 603.3J, HD 603.5J


Core number

Core colour

1
2
3
4

4.4.5 Colour code for power cables according to HD 603.3L


Core number

Core colour

1
1)

2
1)

3
1)

4
1) Black core with white stripes

4.5 Colour Code for Installation Cables JE-LiYCY and JE-Y(St)Y ... Bd according to VDE 0815
Basic Colours
core

Pair 1

Pair 2

Pair 3

Pair 4

a
b

The pairs within a group are identified by the basic colours of the insulation. These colours are repeated in each unit in the same
order. In cables with 2 pairs (stranded as star-quad), the a-core (physical circuit 1) is bl, the b-core (physical circuit 1) is rt, the acore (physical circuit 2) is gr and the b-core (physical circuit 2) is ge.

Group Identification by Printed Helical Tapes ("BdZ")


Groups are identified by helical plastic tapes which carry the printed group number.

Group Identification by Colour Rings ("BdSi")


For the identification of groups, the cores contained therein are marked with colour rings. In cables with more than 12 groups,
the additional groups are identified with coloured helical plastic tapes.

Page 165

SKW | PRAKAB | Products

General technical information

Number of group

10

11

12

13

14

II

III

IV

II

III

IV

II

15

16

17

18

19

20

III

IV

II

III

IV

Ring group in
group unit

Ring colour
4 cores

II

II

8 cores or 4 pairs

II

III

IV

Helix

Ring-type
Ring-type
Ring-type
Ring-type

I
II
III
IV

4.6 Colour code for telecommunications cables according to VDE 0815


J-Y(St)Y ... Lg
core

Pair 1

Pair 2
1)

Pair 3
1)

Pair 4

Pair 5

1)

1)

1)

1) The colour of the a-core of the first pair in each layer (counting pair) is red, in all the other pairs it is white
For more that 5 pairs the colour code is repeated in the same sequence. In cables with 2 pairs (stranded as star-quad),
the a-core (physical circuit 1) is rt, the b-core (physical circuit 1) is sw, the a-core (physical circuit
2) is ws and the b-core (physical circuit 2) is ge.

Number of pairs per layer

Number
of pairs
1

10

12

16

11

20

13

30

10

16

40

13

50

10

15

21

60

12

18

23

100

14

20

25

1) In star quad stranding

Page 166

1)

19

31

SKW | PRAKAB | Products

General technical information

A-2Y(L)2Y, A-2YF(L)2Y, J-H(St)H...Bd


In order to identify the group, a group (tracer group) is identified with a helix of red plastic tape in each layer. The quads in each
group are identified by the basic colour of the core insulation. The colours are repeated in each group in the same sequence.

Quad 1

Quad 2

Quad 3

Quad 4

Quad 5

To distinguish the individual cores of each quad these are identified by colour rings.

a-core physical circuit 1


b-core physical circuit 1
a-core physical circuit 2
b-core physical circuit 2

4.7 Colour code for telecommunications cables according to VE regulations


or TA specification
F-2YA2Y, F-2YC2Y, F-2YJA2Y
The individual pairs are identified by the basic colour and colour rings for the a-core and by the basic colour for the b-core.

a-core physical circuit 1 b-core physical circuit 1 a-core physical circuit 2 b-core physical circuit 2

1) The colour of the a-core of the first star quad in each layer (tracer quad) is black and natural for all the others.

5. Permissible installation conditions


5.1 Permissible Minimum Bending Radius
Insulated wires for fixed installation

d up to 10 mm

Outer diameter d or thickness d (for flat types)


U0/U up to 0.6/1 kV
d above 10 mm up to 25 mm
d above 25 mm

U0/U above 0.6/1 kV

Fixed installed

4d

4d

4d

6d

Preformed

1d

2d

3d

4d

Page 167

SKW | PRAKAB | Products

General technical information

Flexible Installation Cables

d up to 8 mm
Fixed installed

Outer diameter d or thickness d (for flat types)


U0/U up to 0.6/1 kV
d 812 mm
d ab 1220 mm
d above 20 mm

3d

3d

4d

4d

U0/U above 0.6/1 kV


6d

Free in motion

3d

4d

5d

5d

10 d

At inlets

3d

4d

5d

5d

10 d

Forced bending

5d

5d

5d

5d

12 d

Cable trolleys

3d

4d

5d

5d

10 d

Trailing cable
Over deflection pulley

4d

4d

5d

5d

10 d

7.5 d

7.5 d

7.5 d

7.5 d

15 d

Power Cables
Plastic Insulated
U0/U up to 0.6/1 kV
U0/U above 0.6/1 kV
Single-core
Multi-core
Single-core
Multi-core

Paper Insulated
with Lead Jacket
Single-core
Multi-core

Non-armoured

15 d

12 d

15 d

15 d

25 d

15 d

Armoured

15 d

15 d

15 d

15 d

25 d

15 d

d = Outer cable diameter

Telecommunication Cables
Installation- and switchboard cables (F-VYAY, F-YAY, J-Y(St)Y etc.):

7.5 d

Ground cables (F-2YC2Y, A-2YF(L)2Y etc.):

10 d

d = Outer cable diameter

5.2 Permissible Installation Temperatures


When installing power cables, the cable temperature may not fall below:
- Paper insulated cables: +5 C
- Plastic insulated cables with PVC jacket: 5 C
- XLPE insulated cables with PE jacket: 20 C
At lower temperatures, the cable must be sufficiently heated before laying. Care should be taken to ensure that the cable at the
core of the coil also has a sufficient temperature.

5.3 Permissible Tensile Stress for Low- and Medium Voltage Cables
Plastic-insulated

Sheathed cables
without metal jacket
and armouring

Cables with steel-wire


armour

Single-jacket cables
without stress-resistant
armouring

Triple-jacket cables
without stress-resistant
armouring

Pulling head on the conductors

F=sA

F=sA

F=sA

F=sA

Cable stocking

F=sA

F=9d

F=3d

F = 1 d2

Formula symbols: F (tractive force in N), s (tensile strength Cu 50 N/mm2, Al 30 N/mm2), A (total conductor cross-sections in mm2 without
concentric conductor or screen), d (cable diameter in mm)

Page 168

SKW | PRAKAB | Products

General technical information

6. Current carrying capacity & voltage loss 130 kV


General
The layout of a cable system is basically created under consideration of two criteria: The thermal load (current carrying capacity
at which the maximum permissible conductor temperature during normal operation and short circuit conditions is not exceeded)
and the voltage loss on the cable. The bigger of these two calculated nominal conductor cross sections shall be used as
minimum conductor cross section for selecting the appropiate cable.

Thermal load
For the selection of the required nominal conductor cross section the basic current rating is used. This value is defined for the
installations "in air" and "in earth" under exactly specified conditions (load factor, ambient temperature, thermal resistance etc.).
For a wide range of deviating installation conditions, reduction factors are defined in the applicable standards. For the final layout
of the cable system, only values out of the latest issues of these standards shall be used! The neccessary data can be found
also among others in the following standards:

VE-K 516
VE-K 603
VE-K 620
VE/NORM E 8200-604
VE-NORM E 8200-626
VE/NORM E 8200-627

DIN/VDE 0276-603
DIN/VDE 0276-604
DIN/VDE 0276-620
DIN/VDE 0276-621
DIN/VDE 0276-626
DIN/VDE 0276-1000
VDE 0298-4
VDE 0298-8

Voltage loss
Especially for bigger cable lengths (above some 100 meters length) the voltage loss plays the main role for the layout of the
cable system. For this layouting it shall considered, that the conductor temperature is increasing due to the current load and that
therefore also the conductor resistance will increase too. The maximum permissible voltage loss is usually defined in % of the
nominal network voltage. The applicable values can be taken out of the technical connection conditions resp. other equal
publications of the local utilities.
The value of the voltage loss can be calculated - if not otherwise defined - according to the following formula:

U = (P * L * 100 * (RW * cos + XL * sin )) / (U2 * cos )


U
P
L
RW
XL
U

Voltage difference in % of the network voltage


Transmitted power in kW
Cable length in m
Conductor resistance in /km
Inductive resistance in /km
Network voltage in V

Page 169

SKW | PRAKAB | Products

General technical information

7. Packaging
7.1 Type of packaging
R
or K .............Coil
Sp or NB...........One-way plywood coil
T
or B ............Wooden or steel drum

7.2 Drum capacity


Cable

6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62

DA 06
1451
1054
811
618
523
396
356
297
243
232
185
175
143
135
127

DA 07
2277
1617
1288
1020
806
667
560
479
404
336
322
261
249
207
196
159
149
149

DA 08
3560
2622
1993
1515
1309
1048
877
768
645
552
466
448
371
315
301
287
238
226
213
183
172

Length in m per standard supply drum and cable diameter


DA 10
DA 12
DA 14
DA 16
DA 18

4213
3244
2668
2149
1872
1615
1278
1217
1039
901
772
726
632
590
506
487
468
393
377
360
295
281
281
267
253
211
199
199
187

2287
1973
1721
1487
1304
1132
1069
915
858
746
720
618
595
572
480
460
440
420
343
343
326
326
309
257
243
243
229
229
214
214
172
160
160
160

For flat cables: thickness of flat cable is cable diameter


Cable length: length according to table x cable thickness/cable width

Page 170

2891
2556
2195
1950
1817
1595
1387
1312
1159
1091
951
920
859
736
709
682
597
573
549
525
450
429
409
409
389
389
307
307
290
290
290
273
273
256
205
205
205
191
191
191
177
177
177

2488
2375
2111
1862
1764
1583
1538
1327
1286
1131
1093
1056
916
882
848
754
724
694
664
581
554
554
528
528
430
430
407
407
407
385
385
385
302
302
302
283
283
283
264
264
264
264

3389
3054
2736
2608
2316
2256
1985
1781
1679
1629
1446
1400
1230
1188
1145
1145
992
954
954
814
780
780
746
746
623
623
594
594
564
564
564
458
458
433
433
433
407
407
407
339
318
318
318

DA 20

DA 22

DA 24

DA 25

2913
2777
2516
2390
2148
2032
1809
1756
1548
1500
1451
1403
1219
1176
1176
1006
968
968
929
890
779
745
745
711
711
677
581
581
552
552
523
523
523
493
411
411
387
387
387
387

2488
2426
2302
2053
1996
1762
1711
1659
1607
1400
1353
1306
1161
1120
1078
1078
1037
907
871
835
835
798
798
798
653
653
622
622
622
591
591
560
467
467
467
441

2477
2408
2144
2081
2018
1777
1720
1663
1445
1445
1393
1342
1193
1147
1147
1101
1055
923
883
883
883
843
843
803
688
688
654
654
619
619
619
619
585

2507
2435
2167
2101
2035
1850
1791
1731
1671
1504
1450
1397
1397
1194
1194
1146
1098
1098
1098
919
919
877
877
836
836
836
680
680
680
645
645

SKW | PRAKAB | Products

General technical information

7.3 Minimal drum sizes


Smallest permissible core diameter in relation to types of cable and insulated wire
Types

Minimum core diameter

Cables for fixed installation


Insulated wires

20 x DA

Installation cables, single-core

20 x DA

Installation cables, multi-core

15 x DA

Flexible cables

12 x DA

Plastic-insulated cables
Single-core 6 kV

20 x DA

Single-core 10 kV

25 x DA

Multi-core, including 95 mm2 1 kV

15 x DA

Multi-core, including 95 mm 6 kV

20 x DA

Multi-core, including 95 mm 20 kV

25 x DA

Multi-core, greater than 95 mm2 10 kV

20 x DA

Multi-core, greater than 95 mm 20 kV

25 x DA

Multi-core (7 x and more) 1 kV

15 x DA

Telecommunications cable and installation cable for telecommunications installations


Plastic cable

20 x DA

Installation cable

20 x DA

Lead-sheathed paper-insulated cable


Single-core 10 kV

25 x DA

Single-core 10 kV

30 x DA

Multi-core, unarmoured 6 kV

25 x DA

Multi-core, unarmoured 6 kV

20 x DA

Triple lead-sheathed cable, armoured 10 kV

20 x DA

DA = diameter of cable or insulated wire

Page 171

SKW | PRAKAB | Products

General technical information

7.4 Standard delivery drums

d1 d2

Wooden drums
New drum
designation

Size

Flange diam.
d1 mm

Max. winding
diam.

Core diam.
d2 mm

Winding width
mm "b"

Weight
kg

DA06 without helix

600

540

300

330

12

DA07 without helix

700

640

350

370

20

DA08 without helix

800

740

400

430

33

EA08 with helix

800

740

400

405

36

DA10 without helix

10

1000

940

550

600

65

EA10 with helix

10

1000

940

550

580

68

DA12 without helix

12

1200

1120

700

650

105

EA12 with helix

12

1200

1120

700

620

110

DA14 without helix

14

1400

1320

850

750

170

EA14 with helix

14

1400

1320

850

720

175

DA16 without helix

16

1600

1500

900

850

230

EA16 with helix

16

1600

1500

900

800

240

DA18 without helix

18

1800

1700

1000

950

320

EA18 with helix

18

1800

1700

1000

900

330

DA20 without helix

20

2000

1880

1250

1000

400

EA20 with helix

20

2000

1880

1250

920

415

DA22 without helix

22

2200

2000

1300

1100

450

EA22 with helix

22

2200

2000

1300

1020

465

DA24 without helix

24

2400

2200

1450

1100

620

EA24 with helix

24

2400

2200

1450

1020

635

DA25 without helix

25

2500

2300

1500

1150

800

EA25 with helix

25

2500

2300

1500

1070

820

Steel drums
New drum
designation

Size

Flange diam.
d1 mm

Max. winding
diam

Core diam.
d2 mm

Winding width
mm "b"

Weight
kg

10MC

100(3k)

1000

940

600

575

56

12MC

120(4k)

1200

1120

600

660

82

15MC

150(5k)

1500

1400

750

940

150

18MC

180(6k)

1800

1700

1150

895

280

20MC

200(7k)

2000

1800

1200

895

380

22MC

220(8k)

2200

2000

1450

965

475

25MC

250(ZF)

2500

2300

1600

1250

780

Page 172

SKW | PRAKAB | Products

Notes

Page 173

SKW | PRAKAB | Products

Notes

Page 174

SKW | PRAKAB | Products

Notes

Page 175

SKW | PRAKAB | Products

Notes

Page 176

You might also like