Notice dinstallation

Module OEM 13.56MHz (ref. MS-R31 & MS W31)

6 5 4 3 2 1 0

Prcautions dutilisation Attention : Dport max du module de llectronique de contrle: 0,5 m La tension de l'alimentation aux bornes du lecteur doit tre comprise entre 4.5 et 5.5 V. Une alimentation filtre et rgule est fortement recommande. Eloigner autant que possible le module des cbles de transmission informatique ou d'origine de puissance (secteur ou Haute Tension). Les perturbations quils peuvent engendrer peuvent varier en fonction de leur puissance de rayonnement et de leur proximit des lecteurs.

Pin number ISO 2 (2x) MS R31 Wiegand(3x) MS R31 RS232 TTL MS W31 Description Type of signal Description Type of signal Description Type of signal

6 0V input 0V input 0V input

5 +5V input +5V input +5V input

4 code output data0 output Setup input

3 data output data1 output Tx output

2 clock output clock output Rx input

1 Mode Input Mode Input Read Input

0 Nc Nc Nc -

La broche 0 (nc) doit rester non connecte Les signaux de donnes sont compatibles TTL

Important : Le module dans sa version RS232 TTL ne doit pas tre reli directement sur un port RS232. Il est ncessaire dutiliser un convertisseur RS232 RS232 TTL.

Rglages : Aprs avoir intgr le module dans son environnement final, si les performances obtenues sont moindres, il est possible de faire un ajustement pour accorder lantenne du module en fonction de son environnement. Pour cela il faut, laide dun tournevis fin, modifier la valeur de la capacit variable.

Condensateur de rglage

STId 2005 NI1011A02- Ed. 16/12/05

Installation procedure
13.56MHz OEM mdule (ref. MS-R31 & MS W31)

6 5 4 3 2 1 0

Usage recommendations Important: Max. distance between the module and the controller board: 0,5 m Power supply tension at the readers connector should be strictly comprised between 4.5V and 5.5V. Filtered regulated power supply is highly recommended. Keep the reader away from computer or power cables as much as possible. They can generate an electrical perturbation that is function of their proximity and radiation level. Distance to respect between two modules: parallel plan: 30 cm Same plan: 40 cm Perpendicular: 25 cm.

Pin number ISO 2 (2x) Wiegand(3x) RS232 TTL (5X) Description Type of signal Description Type of signal Description Type of signal

6 0V input 0V input 0V input

5 +5V input +5V input +5V input

4 code output data0 output Setup input

3 data output data1 output Tx output

2 clock output clock output Rx input

1 Mode Input Mode Input Read Input

0 Nc Nc Nc -

Pin 0 (nc) must remains unconnected Data signal are TTL compliant

Caution: RS232 TTL modules must not be directly connected to a RS232 COM port. You have to use a RS232 RS232 TTL converter. Antenna tuning: If the reading distances are reduced after the module has been fitted to its final place, you can adjust the antenna. Use a thin screwdriver to modify the capacitor value.

Adjustable capacitor

STId 2005 NI1011A02- Ed. 16/12/05