Fire Control Panels

UL, ULC Listed; FM, CSFM, Addressable Fire Detection and Control
and MEA (NYC) Approved* MINIPLEX® Transponders

Features MINIPLEX transponder

4100U Series MINIPLEX transponders allow Addressable devices Strobe NAC


remotely located initiating and notification
FIRE ALARM

functions: PULL DOWN

C
A
U
T
DISCON NEC T
A .C. PO WER
AND
BATTER Y
BEFOR E
S ER VICING
N
O
I
T
U
I
A
O

x Transponder operation is available as standard or with


SERVI CIN G
BE FO R E
C
N
BA TTER Y
AND
A.C. PO WER
DISC ON NEC T

local mode operation


x Communications with the host fire alarm control panel
use the Remote Unit Interface (RUI) format
Audio NAC Fire Alarm Local Mode Controller

CONTROL
ENABLE
Local
Mode
Control
Alarm

Alarm
Silenced
Local mode
Initiating functions include:
Local
Mode
Active

controller
Alarm
Silence Reset Power
On

x Conventional initiating device circuit (IDC) support


x Addressable device support including TrueAlarm®
analog sensor compatibility**
Notification functions include:
AB C DE F GH I
ZON E SI G AUX

SYSTEM IS NORMAL 1 2 3
08:23:43 am MON 11-DEC-00 JK L
FB
MN O
IO
PQ R
I DN et

ALARMS SYSTEM WARNING S AC Power 4 5 6


Fire Alarm Priority 2 Alarm Superv isory Trouble A larmSilenced STU VW X YZ/
P A L
7 8 9
'SP' ( ) ,0 :
Fire Alarm Prior ity 2 Supv Trouble Alar m Sy stem NE T ADDR
Ack Ack Ack Ack Silence Reset DEL
0

Event More Enter C/ Exi t


Time Info Previous
Menu

Enable On Next
Ar m

Disable Off Auto Lamp


Disarm Test

x Conventional DC notification appliance circuits


Emergency Operating Instructions
Alarm or Warning Condit ion How to Silence Building Signals
System indicator fl ashing. Tone On. Press Ala rm Silence.

How t o Acknowledge / View Events How to Reset System


Press ACKl ocated underflashing indicator. Press System Reset.
Repe at operation until all events are acknowledged. Press Ack tosi el nce tone devic e.
Local tone w lil sil ence.

x Emergency voice/alarm communications


x TrueAlert® addressable strobe and horn notification
Local mode operation provides:
x Default local initiating and notification operation in the On

Off

Auto
On

Off

Auto

event of a communications loss with the host control panel


On On

Off Off

Auto Auto

On On

Off Off

Auto Auto

On On

Off Off

Auto Auto

x Enabling of an optional Local Mode Controller with a Fire Control

local alarm sounder, LED status indicators, and


keyswitch enabled control switches
x Support for IDNet™ addressable devices, conventional 4100U Fire Alarm Control Panel
and TrueAlert addressable notification appliances, and with Voice Control
default output tones from local amplifiers**
Optional modules include: Typical 4100U MINIPLEX System One-Line Drawing
x Digital or Analog audio riser modules for connection to
system audio signals Introduction
x Digital or analog input audio amplifiers with integral 4100U MINIPLEX transponders connect to a host
on-board NACs 4100U Fire Alarm Control Panel using Simplex® remote
x Power supplies with or without battery chargers unit interface (RUI) communications. At the transponder,
x City Connect modules and RS-232 ports for printers or RUI communications are received by the transponder
maintenance terminals interface module and translated into the same internal
communications format that is used in the host control
x Alarm relays, auxiliary relays, additional IDC modules,
panel.
and NAC expansion modules
Remotely located modules. With RUI
Cabinets are equipped with solid doors (beige or communications, the transponder can remotely provide
red) and in two or three bay sizes the same initiating and notification functions that occur at
Listed to: the host control panel without requiring multiple long
x UL Std. 864, Fire Detection and Control (UOJZ), and distance wiring runs. Connections to the host panel are
Smoke Control Service (UUKL) low current communications and audio wiring with
x UL Std. 2017, Process Management Equipment (QVAX) distances up to 2500 ft (762 m).
x UL Std. 1076, Proprietary Alarm Units-Burglar (APOU) Software Revisions. Some of the features detailed and
x UL Std. 1730, Smoke Detector Monitor (UULH) products listed in this document require 4100U System
Software Revision 11.08 or higher. For pre-11.08 system
x ULC Std. S527-99
expansion options, hardware updates may be required.
* See pages 4 and 5 for product that is listed as UL or ULC. This product has been approved by
the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health Contact your local Simplex® product supplier for details.
and Safety Code. See CSFM Listing 7165-0026:251 (non-high rise) and 7170-0026:250 (high
** Simplex fire alarm technology is protected by the following U.S. Patent Numbers:
rise) for allowable values and/or conditions concerning material presented in this document. It
TrueAlarm analog smoke detection: 5,155,468; 5,173,683 and 5,543,777. IDNet and
is subject to re-examination, revision, and possible cancellation. Accepted for use – City of
MAPNET II addressable communications; 4,796,025. TrueAlert addressable notification;
New York Department of Buildings – MEA35-93E. Additional listings may be applicable;
6,313,744 and 6,426,697. SmartSync horn/strobe control; 6,281,789. Flex-35 and Flex-50
contact your local Simplex product supplier for the latest status. Listings and approvals under
amplifier operation; 6,452,491.
Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster.
S4100-0035-5 10/2003
Local Mode Control Operation (Continued)
Introduction (Continued)
Notification Operation. Fire alarm conditions reported
Please refer to document S4100-0031 and the other
against a fire alarm point type within a transponder in
documents listed on page 3 for additional information
local mode will cause all notification appliance circuits in
concerning the extensive initiating and notification
that transponder to:
features of the 4100U fire alarm control panels.
x Sound a general alarm temporal pattern horn tone
Module Bay Description x Activate visible notification appliance circuits
Transponder model 4100-9600 includes a bay Local Mode Module Support. Local mode operation
assembly, a power distribution interface module (PDI), a provides support for the following 4100U modules:
Basic Transponder Interface Module, and an interconnect
harness. Communications with the host fire alarm control x System Power Supplies (SPS), Expansion Power
panel are via a Remote Unit Interface (RUI) connection Supplies (XPS), and Remote Power Supplies (RPS),
that allows for up to 2500 ft (762 m) distance. RUI can including on-board notification appliance circuits
communicate with up to a total of 31 remote devices and (NACs) and expansion signal modules, operated at a
can be either Style 4 or Style 7 communications. temporal pattern,
Transponder model 4100-9601 substitutes a Local x TrueAlert Power Supplies (TPS) including the on-board
Mode Transponder Module for the Basic Transponder signaling line circuits (SLCs)
Module. x IDNet addressable device circuits, including those
on-board the SPS, IDNet expansion modules, and the
Optional Expansion Bays each include a PDI and
quad isolator when used for IDNet communications
accept a variety of optional modules (refer to list starting
on page 4). x 4100U amplifiers will provide their on-board horn tones
(500 Hz) at a temporal pattern through their on-board
The Battery Compartment (bottom) accepts two amplifier NACs
batteries, up to 50 Ah, that can be mounted within the
cabinet. Battery mounting does not interfere with Local Mode Operation Module Exclusion. Modules
available module space. A power supply with battery not listed above but that are listed as compatible with
charger is required for each battery set. MINIPLEX transponders per this document, do not
interfere with local mode operation but are not supported
Packaging Availability during local mode operation.
x Modules are power-limited (except as noted, such as Local Mode Controller
relay modules)
Operation. During local mode operation, an optional
x Enclosure are available for either two or three bay Local Mode Controller will indicate status (see illustration
sizes or for cabinet rack mounting below) and can be enabled using a keyswitch to perform
x Boxes and solid doors are available in beige or red local alarm silence or reset. If alarms occurring during local
(ordered separately) mode are reset using a Local Mode Controller, upon
x Up to eight close-nippled cabinets can be connected at restoration of communications, those alarms will not be
one transponder location (close-nippled is mounted sent to the master controller. If alarms are still present
within 20 ft (6 m) and with interconnecting wiring upon restoration of communications, then the alarm
enclosed in conduit) condition will be reported and host fire alarm control panel
x Refer to document S4100-0037 for enclosure details programmed alarm functions will occur. When
communications are re-established, the local mode
Local Mode Control Operation transponder restores automatically.
Default Stand-Alone Operation. In the event of a Mounting. Local Mode Controllers are mounted on
communications loss with the host fire alarm control three-gang plates, are available in beige or red, and for
panel, model 4100-9601 MINIPLEX Local Mode either flush or semi-flush mounting. (See page 7 for
Transponders provide fire alarm response default details).
operation for its connected devices and appliances per the
following.
Fire Alarm Local Mode Controller
Input Operation. During local mode operation,
TrueAlarm initiating devices connected to the transponder Local
Alarm

Mode
will cause an alarm at their least sensitive alarm threshold. CONTROL Control Alarm
Silenced
ENABLE
x Photoelectric sensors will alarm at 3.7%/ft smoke Local
Mode
obscuration Alarm
Active

Silence Reset Power


x Ionization sensors will alarm at 1.3%/ft obscuration On

x Heat sensors will alarm at a fixed temperature of 135° F See Operating Instruction 579-343
(57° C)
x TrueAlarm device LEDs will be activated to indicate a
device in alarm Local Mode Controller Module
2 S4100-0035-5 10/2003
Typical Multi-Floor MINIPLEX Audio System

FIRE ALARM

PULL DOWN

Seventh floor

Legend:

FIRE ALARM

PULL DOWN
C
A
U
T
I
O
N
DISCONNECT
A. C. POW ER
AND
BAT T ERY
BEF ORE
SERVI CING

SERVI CING
BEF ORE
B AT TERY
AND
A.C. POWER
DIS CONNECT
N
O
I
T
U
A
C MINIPLEX transponder

Strobe NAC

Sixth floor

Speaker NAC

FIRE ALARM

PULL DOWN

TrueAlarm sensors
FIRE ALARM
and IDNet/MAPNET II
Fifth floor PULL DOWN
addressable circuits

Audio riser wiring,


twisted pair
FIRE ALARM

PULL DOWN

RUI communications
wiring, twisted, shielded
pair
Fourth floor

FIRE ALARM

PULL DOWN
C
A
U
T
I
O
N
DISCONNECT
A. C. POW ER
AND
BAT T ERY
BEF ORE
SERVI CING

SERVI CING
BEF ORE
B AT TERY
AND
A.C. POWER
DIS CONNECT
N
O
I
T
U
A
C MINIPLEX transponder

Third floor

AB C DEF GHI
ZONE SI G AUX

SYSTEM IS NORMAL 1 2 3
08:23:43 am MON 11-DEC-00 JKL
FB
M NO
IO
PQ R
I DNet

ALARMS SYSTEM WARNINGS AC Powe r


4 5 6
Fire Alarm Priority 2 Alarm Supervisory Trouble Alarm Silen ced S TU VW X Y Z/
P A L
7 8 9
'SP' ( ) , 0:
Fire Alarm Priority 2 Supv Trouble Alarm System
NE T ADDR
Ack Ack Ack Ack Silence Reset DEL
0

Event More
Enter C/Exit
Time Info Previous
Menu
On Next
Enable
Arm

Off Lamp
Disab le Auto
Disarm Test

Emergency Operating Instructions


Alarm or W arning Condition How to Silence Building Signals
System indicator flashing. Tone On . Press Ala rm Silence.

How to Acknowledge / View Events How to Reset System


Press ACKl ocated under flashing indicator. Press Sy stem Reset.
Repeat operation until all events ar e acknowledged. Press Ack to silence tone device.
Local tone w ill silence.

FIRE ALARM

PULL DOWN

Second floor

On On

Off Off

Auto Auto

On On

Off Off

Auto Auto

On On

Off Off

Auto Auto

On On

Off Off

Auto Auto

Fire Control

4100U Fire Alarm Control Panel


with Voice Control

First floor

Additional 4100U Data Sheet Reference


Subject Data Sheet Subject Data Sheet
Enclosures S4100-0037 Basic Panel Modules and Accessories S4100-0031
LED/Switch Modules S4100-0032 Network Display Unit (NDU) S4100-0036
4100U Audio/Phone Modules S4100-0034 Remote Annunciators S4100-0038
TrueAlert Addressable Products S4009-0003 Remote Battery Charger S4081-0002

3 S4100-0035-5 10/2003
MINIPLEX Transponder Product Selection
Transponder Type
Model Description Supv. Alarm
Basic Transponder, includes bay equipment with power distribution interface, and 4100-0620
4100-9600 87 mA 87 mA
Basic Transponder Interface Module mounted in Block A
Local Mode Transponder, includes bay equipment with power distribution normal 87 mA 87 mA
4100-9601 interface, and 4100-0625 Local Mode Transponder Interface Module mounted in
Block A in local mode 112 mA 112 mA

Local Mode Controller Selection


Model Description Supv. Alarm
4601-9108 Flush mount Red with white Local Mode Controller, 3-gang plate mounted;
flush mount requires a 1-1/2” (38 mm) deep normal 10 mA 10 mA
4601-9109 Surface mount lettering
3-gang box; surface mount controllers include
4601-9110 Flush mount Beige with a matching mounting box; refer to page 7 for in local mode 20 mA 60 mA
4601-9111 Surface mount black lettering details
Communication Modules
Model Description Size Supv. Alarm
4100-6031 City Circuit, with disconnect switches For use with SPS Mounts 20 mA 36 mA
4100-6032 Select one per SPS City Circuit, without disconnect switches only, not RPS on SPS 20 mA 36 mA
4100-6033 Alarm Relay, 3 Form C relays, 2 A @ 32 VDC; for SPS or RPS or RPS 15 mA 37 mA
4100-6038 Dual RS-232 Interface 1 Slot 132 mA 132 mA
4100-6045 Decoder Module 3 Slots 85 mA 163 mA
4100-6048 VESDA® Aspiration System Interface 1 Slot 132 mA 132 mA
4100-9816 Master Clock Interface Module with one standard RS-232 port (see S4100-0033) 1 Slot 132 mA 132 mA
Expansion, System, Remote, and TrueAlert Power Supplies and Accessories
Model Voltage/Listing Description Size Supv. Alarm
4100-5101 120 VAC UL Expansion Power Supply (XPS); 9 A output, 3 built-
4100-5103 120 VAC, Canadian ULC in Class A/B NACs; Canadian models have low battery 2 Blocks 50 mA 50 mA
4100-5102 220-240 VAC UL cutout*
4100-5115 NAC Expansion Module, 3 NACs, Class A/B, mounts on XPS only N.A. 25 mA 25 mA
4100-5111 120 VAC UL System Power Supply (SPS); 9 A power
supply/charger with 250 point IDNet channel, 3 Class 4 Blocks 175 mA 225 mA
4100-5112 120 VAC, Canadian ULC
A/B NACs, and expansion slot for City Circuit or Alarm
4100-5113 220-240 VAC UL Relay option; Canadian model has low battery cutout*
4100-5125 120 VAC UL Remote Power Supply (RPS); 9 A power
supply/charger similar to SPS except no IDNet channel 4 Blocks 150 mA 185 mA
4100-5126 120 VAC, Canadian ULC
or City Circuits, will accept one 4100-6033; Canadian
4100-5127 220-240 VAC UL model has low battery cutout*
4100-5120 120 VAC UL TrueAlert Power Supply (TPS); 3 built-in Class B
addressable Signaling Line Circuits (SLCs) rated 3 A 4 Blocks 88 mA 100 mA
4100-5121 120 VAC, Canadian ULC
each, built-in battery charger, with 2 A auxiliary power
4100-5122 220-240 VAC UL output tap; Canadian model has low battery cutout
4100-5124 TrueAlert SLC Class A Adapter for all 3 SLCs, mounts on TPS only N.A. 7 mA 7 mA
4100-5152 12 VDC Power Option, 2 A maximum 1 Block 1.5 A maximum
4100-0636 Box Interconnection Harness Kit (non-audio); order one for each close-nippled cabinet
Miscellaneous Options and Accessories
Model Description
24 Point I/O Module for external connections, select each point as either a switch input (momentary or maintained) or
4100-1290
an output (for lamp/LED/relay); requires 1 Slot (refer to data sheet S4100-0032 for additional information)
Terminal Block Utility Module; provides 2, 16 position terminal blocks mounted on 4” x 5” single block size, capable of
4100-0632
up to 12 AWG wire (3.31 mm2)
4100-0633 Door Tamper Switch, connects into Transponder Interface Module, one per cabinet assembly if required
4100-0634 120 VAC
Power Distribution Module (PDM) select per system voltage; one required per box
4100-0635 220/230/240 VAC
Green LED Power-on Indicator Kit, required for
4100-9837 Mounts using knockout provided in solid door
ULC listing of MINIPLEX transponder
Series resistor for WSO, IDCs (N.O. water flow and tamper on same circuit, wires after water flow and before tamper)
2081-9031
470 Ÿ, 1 W, encapsulated, two 18 AWG leads (0.82 mm2), 2-1/2” L x 1-3/8” W x 1” H (64 mm x 35 mm x 25 mm)
* Power supply NACs can provide synchronized strobe or SmartSync, two-wire operation. Continued on next page

4 S4100-0035-5 10/2003
MINIPLEX Transponder Product Selection (Continued)
Audio Riser Modules
Model Description Size Supv. Alarm
Dual Channel Analog Audio Riser Module; accepts one or two separate audio signals from
4100-0621 1 Block 0 mA 0 mA
host control panel; mounts in Block B, is controlled by Transponder Interface Module
3-8 Channel Digital Audio Riser Module; similar to analog module, except receives and
4100-0622 1 Block 50 mA 50 mA
decodes a digital input signal with up to eight audio channels; with Non-Alarm Audio input

Analog Emergency Voice/Alarm Communications Equipment, Constant Supervision Compatible*


Model Description Details
4100-1361 25 VRMS output Flex-35, 35 W Amplifier, constant NAC rating = 1.4 A 35 W, or 100
Includes three on-board
4100-1362 70.07 VRMS output supervision compatible Class B audio NACs; NAC rating = 0.5 A speakers
4100-1312 25 VRMS output Flex-50, 50 W Amplifier, constant power is supplied from NAC rating = 2 A 50 W, or 100
supervision compatible an XPS, RPS, or SPS speakers
4100-1313 70.7 VRMS output NAC rating = 0.707 A
100 W Analog Amplifiers with Power Supply, Constant Supervision Compatible
Model/Output Voltage
Power Supply Input/Listing Description Details
25 VRMS 70.7 VRMS
4100-1314 4100-1315 120 VAC, 60 Hz UL Includes six, Class B audio NACs;
Primary
4100-1316 4100-1317 120 VAC, 60 Hz ULC NAC rating = 50 W or 100 speakers ULC
100 W
maximum; 2 A @ 25 VRMS; models
4100-1318 4100-1319 220/230/240 VAC, 50/60 Hz UL Amplifier
1.4 A @ 70.7 VRMS have low
4100-1320 4100-1321 120 VAC, 60 Hz UL battery
Backup
Uses the six Class B NACs of primary dropout
4100-1322 4100-1323 120 VAC, 60 Hz ULC 100 W
amplifier circuit
4100-1324 4100-1325 220/230/240 VAC, 50/60 Hz UL Amplifier

Digital Emergency Voice/Alarm Communications Equipment*


Model Description Details
4100-1363 25 VRMS output Flex-35, 35 W Amplifier, constant NAC rating = 1.4 A 35 W, or 100
Includes three on-board
4100-1364 70.07 VRMS output supervision compatible Class B audio NACs; NAC rating = 0.5 A speakers
4100-1326 25 VRMS output Flex-50, 50 W Amplifier, constant power is supplied from NAC rating = 2 A 50 W, or 100
supervision compatible an XPS, RPS, or SPS speakers
4100-1327 70.7 VRMS output NAC rating = 0.707 A
100 W Digital Amplifiers with Power Supply, Constant Supervision Compatible
Model/Output Voltage
Power Supply Input/Listing Description Details
25 VRMS 70.7 VRMS
4100-1328 4100-1329 120 VAC, 60 Hz UL Includes six, Class B audio NACs;
Primary
4100-1330 4100-1331 120 VAC, 60 Hz ULC NAC rating = 50 W or 100 speakers ULC
100 W
maximum; 2 A @ 25 VRMS; models
4100-1332 4100-1333 220/230/240 VAC, 50/60 Hz UL Amplifier
1.4 A @ 70.7 VRMS have low
4100-1334 4100-1335 120 VAC, 60 Hz UL battery
Backup
Uses the six Class B NACs of primary dropout
4100-1336 4100-1337 120 VAC, 60 Hz ULC 100 W
amplifier circuit
4100-1338 4100-1339 220/230/240 VAC, 50/60 Hz UL Amplifier

Options for use with either Analog or Digital Amplifiers


Model Description Details and Mounting Reference
Flex-35/50 Expansion NAC Module; adds three Mounts on Flex-35/50 assembly; NAC ratings = 1.5 A, 35/50 W,
4100-1245 Choose
Class B audio NACs or 100 speakers maximum; Supv = 0.6 mA, Alarm = 60 mA
one per
Flex-35/50 Class A Adapter Module; converts amplifier Mounts on Flex-35/50 assembly; NAC ratings = 2 A, 50 W, or
4100-1246
three on-board NACS to Class A operation 100 speakers maximum; Supv = 0, Alarm = 30 mA
100 W Amplifier Expansion NAC Module; NAC Provides six additional Class B audio NACs, mounts on 100 W
4100-1248 Choose
ratings = 1.5 A, 50 W, or 100 speakers max. amplifier assembly; Supv = 1.2 mA, Alarm = 120 mA
one per
100 W Class A Adapter Module; NAC ratings = amplifier Converts six on-board NACs to Class A operation, mounts on
4100-1249
2 A, 50 W, or 100 speakers max. 100 W amplifier assembly; Supv = 0, Alarm = 60 mA
25 VRMS Output; NAC
Constant Supervision Supv = 10 mA Converts three Class B audio NACS to
4100-1259 rating = 2 A, 50 W, or 100
Adapter for three NACs; Alarm = 35 mA Class A or Class B Constant Supervision
speakers max.
select per amplifier output NACs; mounts on Flex-35/50 or 100 W
70.7 VRMS Output; NAC (not compatible with amplifier amplifier assembly; use two for the six NACs
Supv = 38 mA
4100-1260 rating = 0.707 A, 50 W, or NAC expansion modules) on 100 W amplifiers;
Alarm = 60 mA
100 speakers max.
Firefighters Telephone Options
Model Description Size Supv. In Use
Expansion Telephone Control Module with three Class B telephone NACS; required when 329 mA
4100-1272 1 Block 75 mA
telephone circuits are mounted in transponder; max.
4100-1273 Telephone Class A Adapter Module; mounts on 4100-1272; no additional current required
* Refer to document S4100-0034 for additional audio information. Continued on next page

5 S4100-0035-5 10/2003
MINIPLEX Transponder Product Selection (Continued)
Audio Expansion Signal Module and Options
Model Description Details and Mounting Reference
Expansion Signal Module; three, 1.5 A Class B Converts one NAC input to three NAC outputs; selects between two
NACs for Audio applications; up to five maximum inputs; for Flex-35/50 amplifiers only, two input NACs are required; Single
4100-5116
per amplifier; NAC rating = 1.5 A, 50 W, or 100 Block module mounts in expansion bay; Supv = 18 mA; Alarm with 100 W
speakers maximum amplifiers = 52 mA; Alarm with Flex-35/50 amplifiers = 80 mA
Expansion Signal Module NAC Expander; NAC Expands module capacity to six, Class B NACs; These
4100-1266
rating = 1.5 A, 50 W, or 100 speakers max. Supv = 0.6 mA; Alarm = 60 mA modules
Expansion Signal Module Class A Adapter; NAC Converts 3 Class B, NACs to Class A; Supv = 0.6 mA; mount on the
4100-1267
rating = 1.5 A, 50 W, or 100 speakers max. Alarm = 30 mA 4100-5116;
Expansion Signal Module Constant Supervision NAC rating = 1.4 A, 50 W, or 100 speakers max.; select one
Adapter; Converts 3 Class B NACs to Constant Current vs operating voltage: 25 VRMS Supv = 10 mA; max. per
4100-1268 4100-5116
Supervision Class B or Class A NACs; for 25 VRMS Alarm = 35 mA; 70.7 VRMS Supv = 38 mA;
25 VRMS or 70.7 VRMS audio 70.7 VRMS Alarm = 60 mA as required

General Audio Options


Model Description
4081-9018 End-of-line resistor harness for 70.7 VRMS NACs; 10 k:, 1 W
4100-2320 Audio Bay-to-Bay Interconnection Harness Kit; order one for each audio bay addition
4100-0637 Audio Box Interconnection Harness Kit; order one for each close-nippled audio cabinet
Initiating Device Circuits (IDCs)
Model Description Size Supv. Alarm
4100-5005 Eight zones, Class B 1 Slot 75 mA 195 mA
4100-5015 Eight zones, Class A 1 Slot 75 mA 195 mA
Addressable Interface Modules
Model Description Size Supv. Alarm
4100-3101 IDNet Module, 250 point capacity With 250 IDNet devices, add – 200 mA 250 mA
4100-3104 IDNet Module, 127 point capacity With 127 IDNet devices, add – 102 mA 127 mA
4100-3105 IDNet Module, 64 point capacity With 64 IDNet devices, add – 51 mA 64 mA
Module without devices – 75 mA 115 mA
IDNet Modules, Specifications for each capacity; Module size = 1 Block
Loading per IDNet device – 0.8 mA 1 mA
Model Description Size Supv. Alarm
®
MAPNET II Module, 127 point capacity, add devices separately; Module without devices – 270 mA 290 mA
4100-3102
Module size = 2 Slots; Loading per MAPNET II device = 1.7 mA Fully loaded module, total – 470 mA 490 mA
Isolator Module for MAPNET II or IDNet communications; converts one SLC into four
4100-3103 1 Slot 50 mA 50 mA
isolated Class A or Class B outputs; up to two Modules can be connected to one SLC
Relay Modules; Nonpower-Limited
Model Description Resistive Ratings Inductive Ratings Size Supv. Alarm
4100-3202 4 DPDT w/feedback 10 A 250 VAC 10 A 250 VAC 2 Slots 15 mA 175 mA
4100-3204 4 DPDT w/feedback 2A 30 VDC/VAC 1/2 A 30 VDC/120 VAC 1 Block 18 mA 70 mA
4100-3206 8 SPDT 3A 30 VDC/120 VAC 1-1/2 A 30 VDC/120 VAC 1 Block 16 mA 200 mA
Current Calculation Notes:
1. For total supervisory current, add panel module currents to base system value and add all external loads panel-powered loads.
2. For total alarm current, add panel module currents to base system alarm current and add all panel NAC loads and all external loads
powered from panel power supplies.

General Specifications

Input Power [System (SPS); Expansion (XPS); 120 VAC Models 3.5 A maximum @ 102 to 132 VAC, 60 Hz
Remote (RPS); TrueAlert Power Supplies (TPS); 1.75 A maximum @ 204 to 264 VAC, 50/60 Hz;
and 100 W amplifiers] 220-240 VAC Models
separate taps for 220/230/240 VAC
Total Power Supply 9 A total @ nominal 28 VDC, including module currents and Output switches to
Power Supply Output Output Rating auxiliary power outputs battery backup
Ratings (System,
Auxiliary Power Tap 2 A maximum @ nominal 28 VDC during mains AC
Expansion, and Remote
failure or brownout
Power Supplies) NACs Programmed
2 A maximum per NAC, 5 A maximum @ nominal 28 VDC conditions
for Auxiliary Power
6.2 Ah to 50 Ah; selectable via programming for batteries below 18 Ah; the SPS is UL
Battery Charger Battery capacity range
listed for up to 110 Ah battery charging for remotely located batteries
(System and Remote
Power Supply) Charger characteristics Temperature compensated, dual rate, recharges depleted batteries within 48 hours per
and performance UL Standard 864, to 70% capacity in 12 hours per ULC Standard S527
Operating Temp. Range 32° to 120°F (0° to 49° C)
Environmental
Operating Humidity Range Up to 93% RH, non-condensing @ 90° F (32° C) maximum

6 S4100-0035-5 10/2003
Local Mode Controller Detail

Matching box is supplied with surface mount


models 4601-9109 (red) and 4601-9111 (beige)

Box dimensions, 6-1/2" (165 mm) 1" (25.4 mm)


into box

Fire Alarm Local Mode Controller


Alarm
Local
Mode
Control Alarm
CONTROL Silenced 4-1/2" 4-5/8"
ENABLE
(114 mm) (117 mm)
Local
Mode
Active
Alarm
Silence Reset Power
On

See Operating Instruction 579-343

1-3/4"
Local Mode Controller dimensions, 6-3/8" (162 mm) (44 mm)

For semi-flush mounting, use a


1-1/2" deep (38 mm) 3-gang box

Expansion Bay Module Loading Reference


Description Mounting
Transponder Interface Modules Block A
Audio Riser Modules Block B
Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Terminal Block Module 1 Block
IDNet Modules 1 Block
4, 2 A Relays 1 Block
NON
4, 10 A Relays 4”, 2 Slots
Block A Block C Block E Block G Power-limited
8, 3 A Relays 1 Block
VESDA Interface 2”, 1 Slot
Class B IDC 2”, 1 Slot
Class A IDC 2”, 1 Slot
MAPNET II Module 4”, 2 Slots
MAPNET II/IDNet Isolator 2”, 1 Slot
Decoder Module 6”, 3 Slots
Block B Block D Block F Block H System, Remote, or TrueAlert Blocks E, F, G & H
Power Supply ONLY
Expansion Power Supply Blocks G & H ONLY
NAC Expansion Module On XPS ONLY
Expansion Bay Chassis Blocks E & F; C & D;
Flex-35 Amplifiers, 2 max /bay*
or A & B
Size Definitions: Block = 4” W x 5” H (102 mm x 127 mm) card area
Flex-50 Amplifiers, 2 max/bay* Blocks E & F or C & D
Slot = 2” W x 8” H (51 mm x 203 mm) motherboard with daughter card 100 W Amplifiers, 1 max/bay Blocks E, F, G & H
100 W Backup Amplifiers, 1 max.
Blocks A, B, C & D
per bay with primary amplifier
Telephone Expansion Module 1 Block
Expansion Signal Module 1 Block
* NOTE: When mounting dual Flex amplifiers on an
expansion bay, special mounting rules apply.

7 S4100-0035-5 10/2003
Enclosure Installation Reference

Front view, box outline without door Side view with door attached

Door thickness
3 Bay height 56" (1422 mm) 1-3/8"(35 mm) Knockout screw/nail holes
(for semi-flush mounting)

Exposed cabinet for


semi-flush mounting
1-3/8" (35 mm)
2 Bay height 40" (1016 mm) minimum

Wall board reference


for semi-flush
mounting, 6" stud

Doors can be hinged left or right Exposed door and


cabinet for semi-
flush mounting
2-3/4" (70 mm)
minimum

Stud alignment
markers, each side

6" stud
4" stud

6-29/32"
24" (610 mm) (175 mm)
8-3/8"
Optional semi-flush (213 mm)
trim kit reference

NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection
shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780.

Tyco, Simplex, the Simplex logo, MAPNET II, IDNet, TrueAlarm, SmartSync, MINIPLEX, and TrueAlert are trademarks of Tyco International Services AG or its affiliates in the
U.S. and/or other countries. VESDA is a trademark of Vision Products Pty Ltd.

Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4100-0035-5 10/2003


www.tycosafetyproducts-usa-wm.com
© 2003 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.

You might also like