July, 1996
INVERTEC V250-S
For use with machine Code Numbers 10102 to 10188
SERVICE MANUAL
Return to Master TOC View Safety Info
22801 St. Clair Ave. Cleveland, Ohio 44117-1199 U.S.A. Tel. (216) 481-8100
SAFETY
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm. The Above For Diesel Engines The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. The Above For Gasoline Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of Safety in Welding & Cutting - ANSI Standard Z49.1 from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of Arc Welding Safety booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.
____________________________________________________ 1.c. Do not add the fuel near an open flame welding arc or when the engine is running. Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporizing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated. ____________________________________________________ 1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment. ____________________________________________________ 1.e. In some cases it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts. ___________________________________________________ 1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running. ___________________________________________________ 1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
Mar 95
SAFETY
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits are electrically hot when the welder is on. Do not touch these hot parts with your bare skin or wet clothing. Wear dry, hole-free gloves to insulate hands.
ii
3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground. In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment: Semiautomatic DC Constant Voltage (Wire) Welder. DC Manual (Stick) Welder. AC Welder with Reduced Voltage Control. 3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically hot. 3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded. 3.e. Ground the work or metal to be welded to a good electrical (earth) ground. 3.f. Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling. 3.h. Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders. 3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock. 3.j. Also see Items 6.c. and 8.
Mar 95
SAFETY
WELDING SPARKS can cause fire or explosion.
6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.
iii
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to Safety in Welding and Cutting (ANSI Standard Z49.1) and the operating information for the equipment being used. 6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been cleaned. For information, purchase Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping That Have Held Hazardous Substances, AWS F4.1 from the American Welding Society (see address above). 6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode. 6.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail. 6.h. Also see item 1.c.
Mar 95
iv
SAFETY
PRCAUTIONS DE SRET
iv
Pour votre propre protection lire et observer toutes les instructions et les prcautions de sret specifiques qui parraissent dans ce manuel aussi bien que les prcautions de sret gnrales suivantes: Sret Pour Soudage A LArc 1. Protegez-vous contre la secousse lectrique: a. Les circuits llectrode et la pice sont sous tension quand la machine souder est en marche. Eviter toujours tout contact entre les parties sous tension et la peau nue ou les vtements mouills. Porter des gants secs et sans trous pour isoler les mains. b. Faire trs attention de bien sisoler de la masse quand on soude dans des endroits humides, ou sur un plancher metallique ou des grilles metalliques, principalement dans les positions assis ou couch pour lesquelles une grande partie du corps peut tre en contact avec la masse. c. Maintenir le porte-lectrode, la pince de masse, le cble de soudage et la machine souder en bon et sr tat defonctionnement. d.Ne jamais plonger le porte-lectrode dans leau pour le refroidir. e. Ne jamais toucher simultanment les parties sous tension des porte-lectrodes connects deux machines souder parce que la tension entre les deux pinces peut tre le total de la tension vide des deux machines. f. Si on utilise la machine souder comme une source de courant pour soudage semi-automatique, ces precautions pour le porte-lectrode sapplicuent aussi au pistolet de soudage. 2. Dans le cas de travail au dessus du niveau du sol, se protger contre les chutes dans le cas ou on recoit un choc. Ne jamais enrouler le cble-lectrode autour de nimporte quelle partie du corps. 3. Un coup darc peut tre plus svre quun coup de soliel, donc: a. Utiliser un bon masque avec un verre filtrant appropri ainsi quun verre blanc afin de se protger les yeux du rayonnement de larc et des projections quand on soude ou quand on regarde larc. b. Porter des vtements convenables afin de protger la peau de soudeur et des aides contre le rayonnement de larc. c. Protger lautre personnel travaillant proximit au soudage laide dcrans appropris et non-inflammables. 4. Des gouttes de laitier en fusion sont mises de larc de soudage. Se protger avec des vtements de protection libres de lhuile, tels que les gants en cuir, chemise paisse, pantalons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de scurit dans la zone de soudage. Utiliser des lunettes avec crans lateraux dans les zones o lon pique le laitier. 6. Eloigner les matriaux inflammables ou les recouvrir afin de prvenir tout risque dincendie d aux tincelles. 7. Quand on ne soude pas, poser la pince une endroit isol de la masse. Un court-circuit accidental peut provoquer un chauffement et un risque dincendie. 8. Sassurer que la masse est connecte le plus prs possible de la zone de travail quil est pratique de le faire. Si on place la masse sur la charpente de la construction ou dautres endroits loigns de la zone de travail, on augmente le risque de voir passer le courant de soudage par les chaines de levage, cbles de grue, ou autres circuits. Cela peut provoquer des risques dincendie ou dechauffement des chaines et des cbles jusqu ce quils se rompent. 9. Assurer une ventilation suffisante dans la zone de soudage. Ceci est particulirement important pour le soudage de tles galvanises plombes, ou cadmies ou tout autre mtal qui produit des fumes toxiques. 10. Ne pas souder en prsence de vapeurs de chlore provenant doprations de dgraissage, nettoyage ou pistolage. La chaleur ou les rayons de larc peuvent ragir avec les vapeurs du solvant pour produire du phosgne (gas fortement toxique) ou autres produits irritants. 11. Pour obtenir de plus amples renseignements sur la sret, voir le code Code for safety in welding and cutting CSA Standard W 117.2-1974.
Mar. 93
vi
INSTALLATION .......................................................................................................................SECTION A TECHNICAL SPECIFICATIONS ..................................................................................................A-2 SAFETY PRECAUTIONS ............................................................................................................A-3 SELECT SUITABLE LOCATION..................................................................................................A-3 INPUT CONNECTIONS ...............................................................................................................A-3 INPUT VOLTAGE RECONNECT PROCEDURE.........................................................................A-4 OUTPUT CONNECTIONS ...........................................................................................................A-5 OPERATION .......................................................................................................................SECTION B SAFETY INSTRUCTIONS ...........................................................................................................B-2 GENERAL DESCRIPTION...........................................................................................................B-2 CONTROLS AND SETTINGS......................................................................................................B-3 CONSTANT CURRENT PROCESSES........................................................................................B-4 PARALLEL OPERATION .............................................................................................................B-5 OVERLOAD PROTECTION.........................................................................................................B-5 THERMAL PROTECTION............................................................................................................B-5 ACCESSORIES .......................................................................................................................SECTION C OPTIONS / ACCESSORIES ........................................................................................................C-2 CABLE PLUGS......................................................................................................................C-2 REMOTE CONTROLS ..........................................................................................................C-2 MAINTENANCE .......................................................................................................................SECTION D INPUT FILTER CAPACITOR DISCHARGE PROCEDURE.........................................................D-2 ROUTINE MAINTENANCE..........................................................................................................D-3 FILTER CAPACITOR CONDITIONING ......................................................................................D-3 LOCATION OF MAINTENANCE COMPONENTS.......................................................................D-4 THEORY OF OPERATION .........................................................................................................SECTION E GENERAL DESCRIPTION...........................................................................................................E-2 INPUT LINE VOLTAGE................................................................................................................E-2 PRE-CHARGE AND PROTECTION ............................................................................................E-3 MAIN TRANSFORMER................................................................................................................E-4 OUTPUT RECTIFICATION AND CONTROL...............................................................................E-5 PROTECTION CIRCUITS............................................................................................................E-6 INSULATED GATE BIPOLAR TRANSISTOR (IGBT) OPERATION............................................E-7 PULSE WIDTH MODULATION (PWM)........................................................................................E-8 TROUBLESHOOTING ................................................................................................................SECTION F HOW TO USE TROUBLESHOOTING GUIDE ......................................................................F-2 PC BOARD TROUBLESHOOTING PROCEDURES.............................................................F-3 TROUBLESHOOTING GUIDE...............................................................................................F-4 TEST PROCEDURES..........................................................................................................F-11 REPAIR AND REPLACEMENT PROCEDURES.................................................................F-43 RETEST AFTER REPAIR....................................................................................................F-77 ELECTRICAL DIAGRAMS.........................................................................................................SECTION G
INVERTEC V250-S
SECTION-A-1
Return to Master TOC
INSTALLATION
TABLE OF CONTENTS -INSTALLATION SECTION-
SECTION-A-1
TECHNICAL SPECIFICATIONS ..................................................................................................A-2 SAFETY PRECAUTIONS ............................................................................................................A-3 SELECT SUITABLE LOCATION..................................................................................................A-3 STACKING.............................................................................................................................A-3 TILTING .................................................................................................................................A-3 HIGH FREQUENCY PRECAUTIONS ...................................................................................A-3 INPUT CONNECTIONS ...............................................................................................................A-3 GROUND CONNECTION......................................................................................................A-3 INPUT SUPPLY CONNECTIONS .........................................................................................A-3 POWER INPUT CONNECTION FOR 60HZ MACHINES ......................................................A-3 POWER INPUT CONNECTION FOR 50/60 HZ MACHINES ................................................A-4 INPUT FUSE AND SUPPLY WIRE .......................................................................................A-4 INPUT VOLTAGE RECONNECT PROCEDURE.........................................................................A-4 OUTPUT CONNECTIONS ...........................................................................................................A-5 REMOTE CONTROL RECEPTACLE ....................................................................................A-5 OUTPUT CABLES .................................................................................................................A-5 QUICK DISCONNECT PLUGS..............................................................................................A-5
INVERTEC V250-S
A-2
Return to Section TOC Return to Master TOC
INSTALLATION
INPUT THREE PHASE SINGLE PHASE
Model 60Hz 50/60 Hz Standard Input Current at Rated Output Voltage 208/230/460 60Hz 59/57/29 200/220/400/440 50/60 Hz 58/58/30/30
A-2
SINGLE PHASE
Model 60Hz 60Hz 60Hz 50/60Hz 50/60Hz 50/60Hz Duty Cycle 35% Duty Cycle 60% Duty Cycle 100% Duty Cycle 35% Duty Cycle 60% Duty Cycle 100% Duty Cycle
(1)
SINGLE PHASE
Welding Current Range 1-250 Amps Constant Open Circuit Voltage 65-80 VDC
RECOMMENDED INPUT WIRE AND FUSE SIZES THREE PHASE SINGLE PHASE
Return to Section TOC Return to Master TOC
Fuse Input (Superlag) Ampere or Rating Breaker on Size Nameplate 50 50 30 50 50 30 30 34 32 16 35 33 18 17 Type 75C Copper Wire in Conduit AWG (IEC) Sizes 10 (6mm2) 10(6mm2) 10 (6mm2) 10 (6mm2) 10 (6mm2) 10 (6mm2) 10 (6mm2) Type 75C Copper Ground Wire in Conduit AWG (IEC) Sizes 10 (6mm2) 10 (6mm2) 10 (6mm2) 10 (6mm2) 10 (6mm2) 10 (6mm2) 10 (6mm2) Fuse Input (Superlag) Ampere or Rating Breaker on Size Nameplate 80 80 40 80 80 40 40 59 57 29 58 58 30 30 Type 75C Copper Wire in Conduit AWG (IEC) Sizes 8 (10mm2) 8 (10mm2) 10 (6mm2) 8 (16mm2) 8 (16mm2) 10 (6mm2) 10 (6mm2) Type 75C Copper Ground Wire in Conduit AWG (IEC) Sizes 10 (6mm2) 10 (6mm2) 10 (6mm2) 10 (6mm2) 10 (6mm2) 10 (6mm2) 10 (6mm2)
Input Voltage Frequency(2) 208/60 230/60 460/60 200/50/60 220/50/60 400/50/60 440/50/60
Input Voltage Frequency(2) 208/60(3) 230/60(3) 460/60 200/50/60 220/50/60 400/50/60 440/50/60
PHYSICAL DIMENSIONS
Return to Section TOC Return to Master TOC
Height 15.0 in. 381 mm
(1) Based on a 10 min. period. (2) Input voltage must be within 10% of rated value. (3) For 1 phase use on 208 or 230 VAC input with output usage above 175A/60% or 200A/35%, the #10 input line cord supplied with the unit should be changed to a #8 or larger conductor cord. () 200 & 208VAC input may not meet NEMA/IEC specifications at 250 Amps.
Weight 36 lbs. 17 Kg
INVERTEC V250-S
A-3
Return to Section TOC Return to Master TOC
INSTALLATION
HIGH FREQUENCY PRECAUTIONS
A-3
If possible locate the V250-S away from radio controlled machinery. The normal operation of the V250-S may adversely affect the operation of RF controlled equipment, which may result in bodily injury or damage to the equipment.
INPUT CONNECTIONS
The Invertec V250-S should be connected only by a qualified electrician. Installation should be made in accordance with all local and national electric codes and the information detailed below.
Be sure to discharge capacitors with the procedure outlined in the Maintenance Section of this manual before working in that area of the equipment.
GROUND CONNECTION
Ground per National Electrical Code for 60Hz machines connect the green lead to earth ground. For 50/60Hz machines connect the ground terminal marked located in the machine on the lower right side the base of the welder to earth ground.
---------------------------------------------------------------------
POWER INPUT CONNECTION FOR 60HZ MACHINES A 10 ft. power cord is provided and wired into the machine. Follow the power cord connection instructions. Incorrect connection may result in equipment damage.
STACKING
V250-Ss cannot be stacked.
Single Phase Input: Connect green lead to ground per U.S. National Electrical Code. Connect black and white leads to power. Wrap red lead with tape to provide 600V insulation. Three Phase Input: Connect green lead to ground per U.S. National Electrical Code. Connect black, red and white leads to power.
TILTING
Return to Section TOC Return to Master TOC Place the machine directly on a secure, level surface or on a recommended undercarriage. The machine may topple over if this procedure is not followed.
INVERTEC V250-S
A-4
Return to Section TOC Return to Master TOC
INSTALLATION
INPUT VOLTAGE RECONNECT PROCEDURE
A-4
POWER INPUT CONNECTION FOR 50/60 HZ MACHINES 1. Connect terminal marked to earth ground per National Electric Code. 2. Connect the supply lines to the line switch. Torque to 3.0 Nm. 3. Install in accordance with all local and national electric codes. The Invertec V250-S 50/60 Hz machine is supplied with one cord connector. The cord connector provides a strain relief for the input power cord as it passes it through the rear access hole. The cord connector is designed for a cord diameter of 7.9 to 27.2mm (.310 to 1.070 in).
When received directly from the factory, units are connected for the highest input voltage, 440 VAC for 50/60 Hz machines and 460 VAC for 60 Hz machines. If 440 or 460 VAC is the desired input, then the machine may be connected to the power system without any setup required inside the reconnect door. However, verify the connection with the following procedure. For other voltages refer to the instructions located on the Reconnect Panel Access Door or follow the instructions below.
CAUTION
Failure to follow these instructions can cause immediate failure of components within the welder. -----------------------------------------------------------------------1. Open the access door on the right side of the machine. 2. For 200-230: Position the large switch to 200-230. For 380-460: Position the large switch to 380-460. 3. Move the A lead to the appropriate terminal. Refer to figure A.1 below.
Strip away outer jacket of cord, trim fillers and insert conductors through cord connector. The jacketed portion of the cord must go through the cord connector. Tighten both connector screws.
RECONNECT PROCEDURE
1. BE SURE POWER SWITCH IS OFF. 2. CONNECT LEAD 'A' TO DESIRED INPUT VOLTAGE RANGE.
440-460V 380-415V 220-230V 200-208V
. .
.
A
Do not operate with wraparound removed. Do not touch electrically live parts. Only qualified persons should install, use or service this equipment.
'A'
IF MACHINE CEASES TO OPERATE (NO METER, NO FAN) AND THERE IS NO OTHER KNOWN FAILURE: CHECK FUSE; REPLACE WITH SPECIFIED FUSE.
VOLTAGE=380-460V
VOLTAGE=200-230V
S21230
INVERTEC V250-S
A-5
Return to Section TOC Return to Master TOC
INSTALLATION
QUICK DISCONNECT PLUGS
A-5
OUTPUT CONNECTIONS
Refer to figure A.2 for the location of the 6 Pin Remote Receptacle and the Output Terminals.
A quick disconnect system is used for the welding cable connections. The welding plug included with the machine is designed to accept a welding cable size of 1/0 to 2/0. 1. Remove 1 in. (25mm) of welding cable insulation.
SMAW SOFT
GTAW
SMAW CRISP
THERMAL
HOT START
4 3
6 7 8 9
85
120 170
2 1 0 10
OUTPUT
50 15 1 250
230
3 2 1
ARC FORCE
6 7 8 9
2. Slide rubber boot onto cable end. The boot end may be trimmed to match the cable diameter. Soap or other lubricant will help to slide the boot over the cable.
10
BOOT
INVERTEC V250-S
WELDING CABLE
25 mm
TRIM
1 in.
OUTPUT TERMINALS
3. 4.
Slide the copper tube into the brass plug. Insert cable into copper tube. Tighten set screw to collapse copper tube. Screw must apply pressure against welding cable. The top of the set screw will be well below the surface of the brass plug after tightening.
SET SCREW
OUTPUT CABLES
Select the output cable size based on Table A.1.
BRASS PLUG
TABLE A.1 Cable Sizes for Combined Length of Electrode and Work Cable ( Copper Cable Rated at 75C). Length up to 150 ft.(46m) up to 250 ft.(72m) Return to Section TOC Return to Master TOC Cable Size 1/0 (50mm2) 2/0 (70mm2) 6.
COPPER TUBE
Slide rubber boot over brass plug. The rubber boot must be positioned to completely cover all electrical surfaces after the plug is locked into the receptacle.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
A-6
NOTES
INVERTEC V250-S
A-6
SECTION-B-1
Return to Master TOC
OPERATION
TABLE OF CONTENTS -OPERATION SECTION-
SECTION-B-1
SAFETY INSTRUCTIONS ...........................................................................................................B-2 GENERAL DESCRIPTION...........................................................................................................B-2 OPERATIONAL FEATURES .................................................................................................B-2 WELDING CAPABILITY ........................................................................................................B-2 LIMITATIONS ........................................................................................................................B-2 CONTROLS AND SETTINGS......................................................................................................B-3 CONSTANT CURRENT PROCESSES........................................................................................B-4 MANUAL ARC WELDING (STICK)........................................................................................B-4 AIR CARBON ARC CUTTING ...............................................................................................B-4 TIG WELDING .......................................................................................................................B-4 PARALLEL OPERATION .............................................................................................................B-5 OVERLOAD PROTECTION.........................................................................................................B-5 THERMAL PROTECTION............................................................................................................B-5
INVERTEC V250-S
B-2
Return to Section TOC Return to Master TOC
OPERATION
GENERAL DESCRIPTION
B-2
Read and understand this entire section before operating your machine.
The Invertec V250-S is a 250 amp arc welding power source that utilizes single or three phase input power, to produce constant current output. The welding response of this Invertec has been optimized for stick (SMAW) and TIG (GTAW).
OPERATIONAL FEATURES
The Invertec V250-S provides continuous total range output current adjustment, selectable welding modes and local or remote output control. Welding characteristics can be controlled via an arc force control. Additionally, starting characteristics can be adjusted via a hot start control.
____________________________________
FUMES AND GASES can be dangerous. Keep your head out of fumes. Use ventilation or exhaust to remove fumes from breathing zone.
WELDING CAPABILITY
The Invertec V250-S is rated at 250 amps, 35% duty cycle (based on a 10 minute cycle). It is also rated at 165 amps, 100% duty cycle, and 200 amps, 60% duty cycle.
LIMITATIONS
The V250-S is not recommended for pipe thawing. The V250-S should not be powered from the auxiliary power supply of an engine welder. Special protection circuits may operate causing loss of output.
____________________________________
WELDING, CUTTING and GOUGING SPARKS can cause fire or explosion Return to Section TOC Return to Master TOC Keep flammable material away. Do not weld, cut or gouge on containers that have held combustibles.
____________________________________
ARC RAYS can burn. Wear eye, ear and body protection.
____________________________________
Only qualified personnel should operate this equipment. Observe all safety information throughout this manual.
INVERTEC V250-S
B-3
Return to Section TOC Return to Master TOC
OPERATION
B-3
8
SMAW SOFT GTAW SMAW CRISP THERMAL
HOT START
2
A
4 3
6 7 8 9
85
120 170
2 1 0 10
OUTPUT
3
Return to Section TOC Return to Master TOC
REMOTE LOCAL
50 15 1 250
230
3 2 1
ARC FORCE
6 7 8 9
10
INVERTEC V250-S
1
O
7
1. Power Switch - Place the lever in the ON position to energize the machine. When the power is on, the fan will operate and the output will be energized in SMAW modes. GTAW mode requires remote trigger to energize the output. 2. Output Control - This controls the output current. Control is provided over the entire output range of the power source with 1 turn of the control knob. This control may be adjusted while under load to change power source output. When using remote control this function becomes the limit setting. 3. Local/Remote Switch - Place in the LOCAL position to allow output adjustment at the machine. Place in the REMOTE position to allow output adjustment at remote pot or amptrol. In Remote, the machine output control pot is the limit setting for remote control. 4. Mode Switch GTAW Optimized for touch start use. Triggering at amphenol is required using an Arc Start Switch, Amptrol or similar means. Short circuit current is limited to approximately 25 amps to aid in touch starting.
CC Soft Best for EXX18 thru EXX28 stick electrodes. Output energized when machine is on. CC Crisp Use this mode for stick welding with EXX10 thru EXX14 electrodes. Output energized when machine is on.
5. Hot Start - Controls the amount of starting energy in SMAW.
INVERTEC V250-S
B-4
Return to Section TOC Return to Master TOC
OPERATION
MANUAL ARC WELDING (STICK)
B-4
6. Arc Force - This control functions in SMAW modes to adjust the Arc Force. The arc is soft at the minimum settings and more forceful or driving at the maximum settings. Higher spatter levels may be present at the maximum settings. RECOMMENDED ARC FORCE/INDUCTANCE SETTINGS FOR SELECTED APPLICATIONS FULL RANGE IS 1-10. 1 is VERY SOFT, 10 IS VERY CRISP Nominal Setting
5
Mode
CC SMAW 1 (soft) CC SMAW 2 (crisp)
Process
EXX18 thru EXX28 stick EXX10 thru EXX14 stick Air Carbon Arc Cutting
None
7. Output Terminals - These quick disconnect terminals provide connection points for the electrode and work cables. Refer to Output Connections in the Installation chapter for proper cable sizes. For positive polarity welding connect the electrode cable to the positive terminal and the work cable to the negative terminal. To weld negative polarity reverse the electrode and work cables. 8. Thermal Shutdown Indicator - This light will illuminate if an internal thermostat has been activated. Machine output will return after the internal components have returned to a normal operating temperature. See Thermal Protection later in this chapter.
TIG WELDING
The V250S is capable of touch start TIG welding. An electrode cable, work cable, Arc Start Switch or Amptrol, TIG torch, and gas supply with regulator are required. Refer to Accessories section of this manual. Touch starting is done as follows: 1. Place the shield cup edge on the work piece. 2. Rock the tungsten down to touch. 3. Trigger the output. 4. Gently rock back the tungsten from the workpiece. Note: The short circuit current is limited to 25 amps to aid in touch starting. Panel output control becomes the current limit setting when in remote control
INVERTEC V250-S
B-5
Return to Section TOC Return to Master TOC
OPERATION
B-5
PARALLEL OPERATION
The Invertecs are operable in parallel. For best results, the currents of each machine should be reasonably well shared. As an example, with two machines set up in parallel for a 300 amp procedure, each machine should be set to deliver approximately 150 amps, not 200 amps from one and 100 amps from the other. This will minimize nuisance feedback conditions. In general, more than two machines in parallel will not be effective due to the voltage requirements of procedures in that power range. To set machine outputs, start with output control pots and arc force pots in identical positions. Adjust outputs and arc forces to maintain current sharing while establishing the proper output current.
OVERLOAD PROTECTION
The machine is electrically protected from producing high output currents. Should the output current exceed 290A, an electronic protection circuit will reduce the current to less than 200A. The machine will continue to produce this low current until the protection circuit is reset. Reset occurs when the output load is removed.
THERMAL PROTECTION
Return to Section TOC Thermostats protect the machine from excessive operating temperatures. Excessive temperatures may be caused by a lack of cooling air or operating the machine beyond the duty cycle and output rating. If excessive operating temperature should occur, the thermostats will prevent output voltage or current. Thermostats are self-resetting once the machine cools sufficiently. If the thermostat shutdown was caused by excessive output or duty cycle and the fan is operating normally, the Power Switch may be left on and the reset should occur within a 15 minute period. If the fan is not turning or the air intake louvers were obstructed, then the power must be switched off for 15 minutes in order to reset. The fan problem or air obstruction must also be corrected.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
B-6
NOTES
INVERTEC V250-S
B-6
SECTION C-1
Return to Master TOC
ACCESSORIES
TABLE OF CONTENTS -ACCESSORIES SECTION-
SECTION C-1
OPTIONS / ACCESSORIES ........................................................................................................C-2 CABLE PLUGS......................................................................................................................C-2 K852-70 .......................................................................................................................C-2 K852-95 .......................................................................................................................C-2 REMOTE CONTROLS ..........................................................................................................C-2 K857.............................................................................................................................C-2 K963 ............................................................................................................................C-2 K870.............................................................................................................................C-2 K814 ............................................................................................................................C-2
INVERTEC V250-S
C-2
Return to Section TOC Return to Master TOC
ACCESSORIES
C-2
OPTIONS / ACCESSORIES
CABLE PLUGS
K852-70 - Cable Plug Kit for 1/0-2/0 cable. Attaches to welding cable to provide quick disconnect from machine. K852-95 - Cable Plug Kit for 2.0-3/0 cable. NOTE: Two K852-70 plugs are included with the V250-S.
REMOTE CONTROLS
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC K857 - Remote Output Control for stick welding. K963 - Hand Amptrol tm for TIG welding. When the V250-Ss Output Control is in the Remote position, the hand Amptrol energizes the output and controls the output remotely. The Hand Amptrol connects directly to the 6 pin Amphenol. K870 - Foot Amptrol tm for TIG welding. When the V250-Ss Output Control is in the REMOTE position, the foot Amptrol energizes the output and controls the output remotely. The Hand Amptrol connects directly to the 6 pin Amphenol.
K814 - Arc Start Switch. Energizes the output for TIG welding if remote output control of the amperage is not desired. When using the Arc Start Switch set the Output Control to the LOCAL position.
INVERTEC V250-S
SECTION D-1
Return to Master TOC
MAINTENANCE
TABLE OF CONTENTS -MAINTENANCE SECTION-
SECTION D-1
INPUT FILTER CAPACITOR DISCHARGE PROCEDURE.........................................................D-2 ROUTINE MAINTENANCE..........................................................................................................D-3 FILTER CAPACITOR CONDITIONING ......................................................................................D-3 LOCATION OF MAINTENANCE COMPONENTS.......................................................................D-4
INVERTEC V250-S
D-2
Return to Section TOC Return to Master TOC
MAINTENANCE
WARNING
ELECTRIC SHOCK can kill.
D-2
Have an electrician install and service this equipment. Turn the input power off at the fuse box before working on equipment. Do not touch electrically hot parts. Prior to Performing preventative maintenance, perform the following capacitor discharge procedure to avoid electric shock. ---------------------------------------------------------------------
4. Obtain a high resistance and high wattage resistor (25-1000 ohms and 25 watts minimum). This resistor is not supplied with machine. NEVER USE A SHORTING STRAP FOR THIS PROCEDURE. 5. Locate the four capacitor terminals (large hex head cap screws) shown in Figure D.1. One pair at the top and one pair at the bottom of the Power Board. 6. Use electrically insulated gloves and insulated pliers. Hold body of the resistor and connect resistor leads across the two capacitor terminals. Hold resistor in place for 10 seconds. DO NOT TOUCH CAPACITOR TERMINALS WITH YOUR BARE HANDS. 7. Repeat discharge procedure for the capacitor on other two terminals. 8. Check voltage across terminals of all capacitors with a DC voltmeter. Polarity of capacitor terminals is marked on PC board above terminals. Voltage should be zero. If any voltage remains, repeat this capacitor discharge procedure.
FIGURE D.1 LOCATION OF INPUT FILTER CAPACITOR TERMINALS. Return to Section TOC Return to Master TOC
POWER BOARD UPPER CAPACITOR TERMINALS
INSULATED PLIERS
INSULATED GLOVES
INVERTEC V250-S
D-3
Return to Section TOC Return to Master TOC
MAINTENANCE
FILTER CAPACITOR CONDITIONING
D-3
ROUTINE MAINTENANCE
1. Perform the following preventive maintenance procedures at least once every six months. It is good practice to keep a preventive maintenance record; a record tag attached to the machine works best. Remove the machine wrap-around cover and perform the input filter capacitor discharge procedure (detail at the beginning of this chapter). Keeping the machine clean will result in cooler operation and higher reliability. Be sure to clean the following areas with a low pressure air stream. See figure D.2 for component locations. Power and control printed circuit boards Power switch Main transformer Input rectifier Heat sink fins Input Filter Capacitors Output Terminals 4. Examine capacitors for leakage or oozing. Replace if needed. 5. Examine the sheet metal case for dents or breakage. Repair the case as required. Keep the case in good condition to ensure that high voltage parts are protected and correct spacings are maintained. All external sheet metal screws must be in place to assure case strength and electrical ground continuity.
2.
A protection circuit is included to monitor the voltage across filter capacitors C1 and C2. In the event that the capacitor voltage is too high, the protection circuit will prevent output. Nominal trip setting is at 230/460 VAC +15%. Reset occurs about 3% lower (230/460 VAC +12%). On new installations, the protection circuit may also prevent output providing all these circumstances are met: 1. Machine is connected for 380-415 or 440-460 VAC input. 2. Machine did not have power applied for many months. 3. Machine will not produce output when power is first switched on. If these circumstances apply, the proper action is to switch the machine on and let it idle for up to 30 minutes. This is required to condition the filter capacitors after an extended storage time. The protection circuit will automatically reset once the capacitor conditioning and resultant voltage levels are acceptable. It may be necessary to turn the power switch off and back on again after this period.
3.
6. Check electrical ground continuity. Using an ohmmeter, measure resistance between either output terminal and an unpainted surface of the machine case. (See Figure D.2 for locations.) Meter reading should be 500,000 ohms or more. If meter reading is less than 500,000 ohms, check for electrical components that are not properly insulated from the case. Correct insulation if needed. 7. Replace machine cover and screws.
INVERTEC V250-S
D-4
Return to Section TOC Return to Master TOC
MAINTENANCE
FIGURE D.2 LOCATION OF MAINTENANCE COMPONENTS.
D-4
CONTROL PC BOARD
INPUT RECTIFIER
MAIN TRANSFORMER
AUXILIARY TRANSFORMER
INVERTEC V250-S
THEORY OF OPERATION
TABLE OF CONTENTS -THEORY OF OPERATION SECTIONGENERAL DESCRIPTION...........................................................................................................E-2 INPUT LINE VOLTAGE................................................................................................................E-2 PRE-CHARGE AND PROTECTION ............................................................................................E-3 MAIN TRANSFORMER................................................................................................................E-4 OUTPUT RECTIFICATION AND CONTROL...............................................................................E-5 PROTECTION CIRCUITS............................................................................................................E-6 INSULATED GATE BIPOLAR TRANSISTOR (IGBT) OPERATION............................................E-7 PULSE WIDTH MODULATION (PWM)........................................................................................E-8
E-1
INVERTEC V250-S
THEORY OF OPERATION
E-2
GENERAL DESCRIPTION
The Invertec V250-S is a 250 amp arc welding power source that utilizes either single or three phase input power to produce a constant current output. The output response of this machine has been optimized for the SMAW and TIG welding processes. FIGURE E.1 - INPUT VOLTAGE CIRCUITS
MAIN TRANSFORMER
IGBT
R E C O N N E C T S W I T C H
CAPACITOR
IGBT
SHUNT
IGBT
CURRENT TRANSFORMER
CAPACITOR
IGBT
"A" L E A D
FAN MOTORS
O V E R V O L T A G E
F E E D B A C K
THERMOSTATS
F E E D B A C K
CONTROL BOARD
THERMAL LIGHT
18VAC
The auxiliary transformer develops the appropriate AC voltages to operate the cooling fans and the control board.
NOTE: Unshaded areas of block logic diagrams are the subject of discussion. INVERTEC V250-S
THEORY OF OPERATION
FIGURE E.2 PROTECTION AND PRE-CHARGE CIRCUITS
E-3
MAIN TRANSFORMER
IGBT
R E C O N N E C T S W I T C H
CAPACITOR
IGBT
SHUNT
IGBT
CURRENT TRANSFORMER
CAPACITOR
IGBT
"A" L E A D
FAN MOTORS
O V E R V O L T A G E
F E E D B A C K
THERMOSTATS
F E E D B A C K
CONTROL BOARD
THERMAL LIGHT
18VAC
NOTE: Unshaded areas of block logic diagrams are the subject of discussion. INVERTEC V250-S
THEORY OF OPERATION
FIGURE E.3 MAIN TRANSFORMER
E-4
MAIN TRANSFORMER
IGBT
R E C O N N E C T S W I T C H
CAPACITOR
IGBT
SHUNT
IGBT
CURRENT TRANSFORMER
CAPACITOR
IGBT
"A" L E A D
FAN MOTORS
O V E R V O L T A G E
F E E D B A C K
THERMOSTATS
F E E D B A C K
CONTROL BOARD
THERMAL LIGHT
18VAC
MAIN TRANSFORMER
Each IGBT pair acts as a switch assembly. Each assembly feeds a separate, oppositely wound primary winding of the main transformer. The reverse directions of current flow through the main transformer primaries and the offset timing of the IGBT pairs induce an AC square wave output signal at the secondary of the main transformer. The DC current flow through each primary winding is redirected or clamped back to each respective filter capacitor when the IGBTs are turned off. This is needed due to the inductance of the transformer primary winding. The primary currents also pass through the current transformer which sends a signal to the control board. If the primary currents are not equal the control board compensates by adjusting the IGBT gate signals. The firing of both IGBT pairs occurs during halves of the 50 microsecond intervals, creating a constant 20 KHZ output.
NOTE: Unshaded areas of block logic diagrams are the subject of discussion. INVERTEC V250-S
THEORY OF OPERATION
FIGURE E.4 OUTPUT RECTIFICATION AND CONTROL
E-5
MAIN TRANSFORMER
IGBT
R E C O N N E C T S W I T C H
CAPACITOR
IGBT
SHUNT
IGBT
CURRENT TRANSFORMER
CAPACITOR
IGBT
"A" L E A D
FAN MOTORS
O V E R V O L T A G E
F E E D B A C K
THERMOSTATS
F E E D B A C K
CONTROL BOARD
THERMAL LIGHT
18VAC
NOTE: Unshaded areas of block logic diagrams are the subject of discussion. INVERTEC V250-S
THEORY OF OPERATION
E-6
PROTECTION CIRCUITS
Protective circuits are designed into the V250-S machine to sense trouble and shut down the machine before the trouble damages the internal machine components. Both overload and thermal protection circuits are included.
OVERLOAD PROTECTION
The V250-S is electrically protected from producing high output currents. Should the output current exceed 290 amps, an electronic protection circuit will reduce the current to less than 200 amps. Lincoln Electric refers to this current reduction as Fold Back. The machine will continue to produce this low current until the protection circuit is reset. Reset occurs when the output load is removed. A protection circuit is included to monitor the voltage across the input filter capacitors. In the event that the capacitor voltage is too high, the protection circuit will prevent output. On new installations, the protection circuit may prevent output, due to unbalanced capacitor leakages, providing the following circumstances are met: 1. Machine is connected for 380 - 460VAC input. 2. Machine did not have power applied for many months. 3. Improper connections. 4. Internal component damage.
THERMAL PROTECTION
Thermostats protect the machine from excessive operating temperatures. Excessive temperatures may be caused by a lack of cooling air or operating the machine beyond the duty cycle and output rating. If excessive operating temperature should occur, the thermostat will prevent output voltage or current and the thermal indicator light will glow. Thermostats are self-resetting once the machine cools sufficiently. If the thermostat shutdown was caused be excessive output or duty cycle and the fan is operating normally, the power switch may be left on and the reset should occur within 15 minute period. If the fan is not turning or the air intake louvers were obstructed, then the power must be switched off for 15 minutes in order to reset. The fan problem or air obstruction must be corrected.
NOTE: Unshaded areas of block logic diagrams are the subject of discussion. INVERTEC V250-S
THEORY OF OPERATION
E-7
Drawing B shows the IGBT in an active mode. When the gate signal, a positive DC voltage relative to the
n+ p
n+
n+
n+ p
n-
n-
n+ p+
n+ p+
DRAIN
DRAIN
A. PASSIVE
B. ACTIVE
INVERTEC V250-S
THEORY OF OPERATION
E-8
MINIMUM OUTPUT
By controlling the duration of the gate signal, the IGBT is turned on and off for different durations during a cycle. The top drawing below shows the minimum output signal possible over a 50-microsecond time period.
MAXIMUM OUTPUT
By holding the gate signals on for 24 microseconds each and allowing only 2 microseconds of dwell time (off time) during the 50-microsecond cycle, the output is maximized. The darkened area under the top curve can be compared to the area under the bottom curve. The more dark area under the curve, the more power is present.
An IGBT group consists of two IGBT modules feeding one transformer primary winding.
sec
48 50
sec sec
sec
MINIMUM OUTPUT
24 sec
SECTION F-1
TROUBLESHOOTING AND REPAIR SECTION.........................................................................SECTION F HOW TO USE TROUBLESHOOTING GUIDE.............................................................................F-2 PC BOARD TROUBLESHOOTING PROCEDURES ...................................................................F-3 TROUBLESHOOTING GUIDE .....................................................................................................F-4 TEST PROCEDURES AUXILIARY TRANSFORMER TEST ...................................................................................F-11 INPUT RECTIFIER TEST ....................................................................................................F-15 POWER BOARD RESISTANCE TEST................................................................................F-19 OUTPUT DIODE TEST........................................................................................................F-23 POWER BOARD VOLTAGE TEST......................................................................................F-27 CONTROL BOARD VOLTAGE TEST..................................................................................F-31 PROTECTION CIRCUIT TEST............................................................................................F-35 CAPACITOR BALANCE TEST ............................................................................................F-39 REPAIR AND REPLACEMENT PROCEDURES CONTROL BOARD REMOVAL AND REPLACEMENT.......................................................F-43 POWER BOARD REMOVAL AND REPLACEMENT...........................................................F-45 FILTER CAPACITOR REMOVAL AND REPLACEMENT....................................................F-49 INPUT RECTIFIER BRIDGE REMOVAL AND REPLACEMENT ........................................F-53 OUTPUT DIODE ASSEMBLY REMOVAL AND REPLACEMENT ......................................F-57 (MACHINE CODES BELOW 10150) OUTPUT DIODE ASSEMBLY REMOVAL AND REPLACEMENT ......................................F-61 (MACHINE CODES ABOVE 10150) MAIN TRANSFORMER REMOVAL AND REPLACEMENT ................................................F-65 (MACHINE CODES BELOW 10150) MAIN TRANSFORMER REMOVAL AND REPLACEMENT ................................................F-71 (MACHINE CODES ABOVE 10150) RETEST AFTER REPAIR ..........................................................................................................F-77
INVERTEC V250-S
F-2
Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual. __________________________________________________________________________ This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below.
Step 1. LOCATE PROBLEM (SYMPTOM). Look under the column labeled PROBLEM (SYMPTOMS). This column describes possible symptoms that the machine may exhibit. Find the listing that best describes the symptom that the machine is exhibiting. Symptoms are grouped into the following categories: output problems and welding problems. Step 2. PERFORM EXTERNAL TESTS. The second column labeled POSSIBLE AREAS OF MISADJUSTMENT(S) lists the obvious external possibilities that may contribute to the machine symptom. Perform these tests/checks in the order listed. In general, these tests can be conducted without removing the case wrap-around cover.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353.
_____________________________________________________________
OSCILLOSCOPE WARNING
Return to Section TOC Return to Master TOC
WARNING
Do not use oscilloscopes and other test equipment which are powered by 115 VAC. This equipment should not be used with inverter-type machines, such as Invertec V250-S. There are high voltages present, which are floating off case ground (floating ground). Connecting the ground lead of a test probe (which may be connected to the case of the test equipment) to a high voltage potential presents a shock hazard as well as the possibility of damage to the equipment in question. _____________________________________________________________________ INVERTEC V250-S
F-3
- Remove the P.C. Board from the staticshielding bag and place it directly into the equipment. Dont set the P.C. Board on or near paper, plastic or cloth which could have a static charge. If the P.C. Board cant be installed immediately, put it back in the staticshielding bag. - If the P.C. Board uses protective shorting jumpers, dont remove them until installation is complete. - If you return a P.C. Board to The Lincoln Electric Company for credit, it must be in the static-shielding bag. This will prevent further damage and allow proper failure analysis. 4. Test the machine to determine if the failure symptom has been corrected by the replacement PC board. NOTE: It is desirable to have a spare (known good) PC board available for PC board troubleshooting. NOTE: Allow the machine to heat up so that all electrical components can reach their operating temperature. 5. Remove the replacement PC board and substitute it with the original PC board to recreate the original problem. a. If the original problem does not reappear by substituting the original board, then the PC board was not the problem. Continue to look for bad connections in the control wiring harness, junction blocks, and terminal strips. b. If the original problem is recreated by the substitution of the original board, then the PC board was the problem. Reinstall the replacement PC board and test the machine. 6. Always indicate that this procedure was followed when warranty reports are to be submitted. NOTE: Following this procedure and writing on the warranty report, INSTALLED AND SWITCHED PC BOARDS TO VERIFY PROBLEM, will help avoid denial of legitimate PC board warranty claims.
_______________________________
CAUTION: Sometimes machine failures appear to be due to PC board failures. These problems can sometimes be traced to poor electrical connections. To avoid problems when troubleshooting and replacing PC boards, please use the following procedure: 1. Determine to the best of your technical ability that the PC board is the most likely component causing the failure symptom. 2. Check for loose connections at the PC board to assure that the PC board is properly connected. 3. If the problem persists, replace the suspect PC board using standard practices to avoid static electrical damage and electrical shock. Read the warning inside the static resistant bag and perform the following procedures: P.C. Board can be damaged by static electricity. - Remove your bodys static charge before opening the static-shielding bag. Wear an anti-static wrist strap. For safety, use a 1 Meg ohm resistive cord connected to a grounded part of the equipment frame.
ATTENTION Static-Sensitive Devices Handle only at Static-Safe Workstations Reusable Container Do Not Destroy
- If you dont have a wrist strap, touch an unpainted, grounded, part of the equipment frame. Keep touching the frame to prevent static build-up. Be sure not to touch any electrically live parts at the same time. - Tools which come in contact with the P.C. Board must be either conductive, anti-static or static-dissipative. INVERTEC V250-S
F-4
Return to Section TOC Return to Master TOC
F-4
PROBLEMS (SYMPTOMS)
Major physical or electrical damage Contact your local Lincoln is observed when cover wrap-around Authorized Field Service Facility. is removed.
1. The input power switch must be in the ON position. 2. Make sure the input voltage is correct for the machine.
1. The power switch (S1) may be faulty. Check or replace. 2. Check for loose or broken leads between the power switch (S1) and the input rectifier D9. See wiring diagram.
3. If the machine is set for singlephase operation, inspect to assure that the WHITE and 3. Perform the Auxiliary Transformer Test. BLACK leads are connected properly and the RED lead is not connected and is insulated. 4. Check that the input voltage setup switch and jumper A (the reconnect auxiliary jumper) are in the proper position for the input voltage being applied. Refer to Input Voltage Reconnect Procedure in the Installation Chapter. 5. Check continuity of the 0.6-amp slow blow fuse located on the reconnect panel.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.
INVERTEC V250-S
F-5
Return to Section TOC Return to Master TOC
F-5
PROBLEMS (SYMPTOMS)
1. The mode switch must be in one of the SMAW modes or if in the GTAW mode the remote trigger circuit must be activated.
2. Check for loose or broken connections on the high current 2. The Local/Remote switch (S3) carrying parts of the V250-S. must be in the LOCAL position (i.e., output diodes, output unless a remote control device is terminals, shunt and main attached to the remote transformer connections.) receptacle. 3. Check the continuity of the 3. If the machine has not been used normally closed thermostats and for a long time and is connected associated wiring. See wiring for 380 VAC or higher, the diagram. capacitors may need conditioning. See Input Filter Capacitor 4. Perform the Output Diode Test. Conditioning. 5. Perform the Capacitor Balance 4. The machine may be overheated. Test. Check the thermal indicator light. Wait for the machine to cool and 6. Perform the Protection Circuit the thermostats to reset. Test. 7. Perform the Power Board Voltage Checks.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.
INVERTEC V250-S
F-6
Return to Section TOC Return to Master TOC
F-6
PROBLEMS (SYMPTOMS)
1. Check the input voltages and 1. Check Local/Remote switch (S3) reconnection procedures. Make and associated wiring for loose or sure the input voltage is correct faulty connections. for the machine. See Input Voltage Reconnect Procedure. 2. Check Mode Switch (S2) and associated wiring for loose or 2. Check or replace remote control faulty connections. device. (If used) 3. If the machine is connected for 380VAC input or higher, perform the Capacitor Balance Test. 4. The power board may be faulty. Replace. 5. The control board may be faulty. Replace.
Remote output control not functioning. The machine operates normally on LOCAL control. Return to Section TOC Return to Master TOC
1. Make sure the Local/Remote switch (S3) is in the REMOTE position. 2. The remote control device may be faulty. Replace.
1. Check the Local/Remote switch (S3) and the associated wiring. See wiring diagram. 2. Check for loose or faulty connections at the remote control receptacle.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.
INVERTEC V250-S
F-7
Return to Section TOC Return to Master TOC
F-7
PROBLEMS (SYMPTOMS)
1. Inspect input leads for possible 1. Inspect interior of machine for shorts or grounds or mis-connecphysical signs of electrical and tions. heat damage. Replace any damaged components after conduct2. Install new fuses and reapply ing the following tests. power. If fuses open again, consult a Lincoln Authorized Field 2. Perform the Input Rectifier Test. Service Facility. 3. Perform Power Board Resistance Test. 4. Check the reconnect switch and associated leads for shorts or faulty wiring.
The machine operates normally 1. Check the input voltage and input 1. Perform the Capacitor Balance Test. when connected for 200 - 230VAC voltage reconnect procedures. input. There is no output when the See Installation Section of this manual. 2. Perform the Protection Circuit machine is connected to 380VAC or Test. higher. 3. Perform the Auxiliary Transformer Test. 4. Perform the Power Board Resistance Test.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.
INVERTEC V250-S
F-8
Return to Section TOC Return to Master TOC
F-8
PROBLEMS (SYMPTOMS)
1. This may be normal operation. If 1. Perform the Output Diode Test. the output current exceeds 290 amps, an electronic protection 2. The control board may be faulty. circuit will reduce the current to Replace. less than 200 amps. The machine will continue to produce this low current until the protection circuit is reset. Reset occurs when the output load is removed. 2. Check the input voltage and input voltage reconnect procedures. See Input Voltage Reconnect Procedure. 3. Check for loose or faulty welding cables.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.
INVERTEC V250-S
F-9
Return to Section TOC Return to Master TOC
F-9
PROBLEMS (SYMPTOMS)
1. Make sure the machine settings are correct for the weld process being used. 2. Check machine performance on LOCAL control. If OK then the remote control device may be faulty. Check or replace. 3. Check the input voltages and input voltage reconnect procedures. See Installation Section of this manual.
1. Check the operation of the mode switch (S2) and the associated circuitry. See wiring diagram. 2. Check for loose or faulty connections in the heavy current carrying leads (i,e,. output diodes, output terminals, shunt and main transformer.) 3. Perform Output Diode Test. 4. Perform Control Board Voltage Test.
1. Check for loose or faulty welding 1. Check for loose or faulty conneccables. tions in the heavy current carrying leads (i,e,. output diodes, output 2. Is the electrode DRY? Try weldterminals, shunt and main transing with another electrode from a former.) different container. Make sure you have the correct electrode for 2. Perform Output Diode Test. the application. 3. Make sure the machine settings are correct for the weld process being used. 3. Perform Control Board Voltage Test.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-10
NOTES
INVERTEC V250-S
F-10
F-11
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
TEST DESCRIPTION
This test will determine if the auxiliary transformer is functional when the correct primary voltage is applied to the primary winding.
MATERIALS NEEDED
Volt/ohmmeter Machine wiring diagram 5/16 nut-driver 230VAC isolated power supply
INVERTEC V250-S
F-12
1J7 4J7
Return to Section TOC Return to Master TOC
2J7 5J7
3J7 6J7
INVERTEC V250-S
F-13
7. If the correct test voltages are present the auxiliary transformer is good. 8. If any of the voltages are missing or very low, with the proper primary voltage applied, the auxiliary transformer may be faulty. Replace. 9. If the auxiliary transformer tests good but does not function when connected to the V250-S check the harness wiring to the auxiliary transformer. See wiring diagram.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-14
NOTES
INVERTEC V250-S
F-14
F-15
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
TEST DESCRIPTION
This test will help determine if the input rectifier has shorted or open diodes.
MATERIALS NEEDED
Analog voltmeter/ohmmeter (Multimeter) Phillips head screwdriver Wiring diagram
INVERTEC V250-S
F-16
#207 #207A
A
Return to Section TOC Return to Master TOC
B C
#209
Return to Section TOC Return to Master TOC
INVERTEC V250-S
F-17
6. If the Input Rectifier does not meet the acceptable readings outlined in Table F.2. the component may be faulty. Replace. Note: Before replacing the Input Rectifier(D9) check the input power switch (S1) and perform the Power Board Resistance Test . Also check for leaky or faulty filter capacitors. 7. When installing a new Input Rectifier, torque the mounting nuts to 44IN-LBS. A thin coating of Dow Corning 340 Heat Sink Compound (Lincoln E1868) is recommended. Torque the lead terminals to 31INLBS. See Input Rectifier Bridge Removal And Replacement.
8. If the Input Rectifier is good be sure to reconnect leads #207, #207A and #209 to the correct terminals and torque to 31IN-LBS. See wiring diagram and Figure F.2.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-18
NOTES
INVERTEC V250-S
F-18
F-19
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
TEST DESCRIPTION
This test will help determine if the Power Board has any shorted or leaky power diodes or Insulated Gate Bipolar Transistors. Also it will help to indicate any shorted filter capacitors.
MATERIALS NEEDED
Return to Section TOC Return to Master TOC Analog voltmeter/ohmmeter (Multimeter) Wiring diagram
INVERTEC V250-S
F-20
207A
+
202A
DANGER
HIGH VOLTAGE CAN KILL
209 208
203A
+
206
205
INVERTEC V250-S
F-21
202A 201 205 203A 208 203A 206 208 206 205
6. If the power board does not meet the acceptable readings outlined in Table F.3. the board may be faulty. Replace. See Power Board Removal and Replacement Procedure. Note: Complete power board and filter capacitor replacement is recommended . 7. If the power board passes the resistance test proceed to the Power Board Voltage Test. Note: Reconnect leads #201, #204, #205 and #208 to their appropriate terminals.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-22
NOTES
INVERTEC V250-S
F-22
F-23
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
TEST DESCRIPTION
This test will help determine if any of the output diodes are shorted.
MATERIALS NEEDED
Return to Section TOC Return to Master TOC Analog voltmeter/ohmmeter (Multimeter) Wiring diagram. Note: Output diode polarity will vary with machine codes.
INVERTEC V250-S
F-24
SMAW SOFT
GTAW
SMAW CRISP
THERMAL
HOT START
4 3
6 7 8 9
85
120 170
2 1 0 10
OUTPUT
50 15
REMOTE LOCAL
230 1 250
3 2 1
ARC FORCE
6 7 8 9
10
INVERTEC V250-S
INVERTEC V250-S
F-25
INVERTEC V250-S
O
+
Return to Section TOC Return to Master TOC
PR
-P RO B
OB E
Figure F.5 Meter Probes.
5. If more than 200 ohms is measured the output diodes are not shorted. 6. If less than 200 ohms is measured, one or more output diodes or snubbers may be shorted or leaky. 7. Perform Filter Capacitor Discharge Procedure detailed in Maintenance Section.
8. Locate output diodes and snubbers. See Figure F.6. for machine codes 10102 and 10103 only. See Figure F.7. for machine codes 10187 and 10188 only. 9. Test all output diodes and snubbers (if used) individually.
INVERTEC V250-S
F-26
Figure F.6 Output Diodes and Snubber Locations (Codes 10102 and 10103)
DIODE MODULES
Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC
Figure F.7 Output Diode Module Locations (Codes 10187 and 10188)
INVERTEC V250-S
F-27
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
TEST DESCRIPTION
This test will aid the technician in determining if the voltage board or some other machine component may be faulty.
MATERIALS NEEDED
Voltmeter/ohmmeter (Multimeter) Wiring diagram. Power board schematic drawing.
INVERTEC V250-S
F-28
#308 (1J6)
PLUG J6
J6
204
201
208
209
205
207A
203A
DANGER
20
INVERTEC V250-S
F-29
TEST DESCRIPTION
The PWM pulse drive from the control board to the pulse transformer primary located on the power board.
TEST POINTS
Lead #307 (2J6) to Negative output terminal
TEST CONDITIONS
No load on the machine - the mode switch in SMAW position.
The PWM pulse drive from the control board to the pulse transformer primary located on the power board.
14VDC.
The PWM pulse drive from the control board to the pulse transformer primary located on the power board.
7VDC.
The PWM pulse drive from the control board to the pulse transformer primary located on the power board.
7VDC.
12VDC
This voltage should be present only after the protection circuit as been satisfied.
This low voltage will be present when the protection circuit has determined that the filter capacitor voltage is acceptable. Note: The CR1 charge relay should be activated.
0 to 1VDC.
This voltage will be present unit the protection circuit determines that the filter capacitor is at an acceptable level. Note: The CR1 charge relay will not be activated.
15VDC.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-30
NOTES
INVERTEC V250-S
F-30
F-31
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
TEST DESCRIPTION
This test will aid the technician in determining if the control board or some other machine component may be faulty.
MATERIALS NEEDED
Voltmeter/ohmmeter (Multimeter) Wiring diagram. Control board schematic drawing.
INVERTEC V250-S
F-32
1J5 (#322)
1J3 (#375)
J1
J2
J5
4J5 (#318)
J3
J4
G2666-[ ]
V250S CONTROL
Figure F.9 Plugs J1-J5 on Control Board
INVERTEC V250-S
F-33
TEST DESCRIPTION
The 18VAC from the auxiliary transformer to the control board.
TEST POINTS
Red lead (1J1) to Red lead (3J1)
TEST CONDITIONS
18VAC The correct input voltage Note: voltage will vary with applied to the V250-S and input line voltage. the input power switch (S1) in the ON position.
0 VDC.
12VDC.
100 mV.
15VDC.
The correct input voltage applied to the V250-S and the input power switch (S1) in the ON position.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-34
NOTES
INVERTEC V250-S
F-34
F-35
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
TEST DESCRIPTION
This check will aid the technician in the understanding and evaluation of the V250-S protection circuit.
MATERIALS NEEDED
Return to Section TOC Return to Master TOC Voltmeter/ohmmeter (Multimeter) Machine wiring diagram Protection circuit simplified wiring diagram
INVERTEC V250-S
F-36
8J2
6J2
J1
J2
J5
J3
J4
1J2 2J2
G2666-[ ]
V250S CONTROL
#308 (1J6)
PLUG J6
J6
204
201
208
209
205
F-37
CONTROL BOARD
TIMER
(4J6)
+15VDC
#311
(2J2)
O V E R V O L T A G E
D E T E C T I O N
(5J6)
#313
(8J2)
+15VDC
(6J6)
#309 #310
(1J2)
(3J6)
(6J2)
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-38
NOTES
INVERTEC V250-S
F-38
F-39
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
TEST DESCRIPTION
This test will help the technician to determine if the input filter capacitors are being charged equally and to the correct voltage levels. Note: This test should only be conducted with the V250-S reconnect switch and A jumper configured for 380VAC and above. Return to Section TOC Return to Master TOC
MATERIALS NEEDED
Voltmeter/ohmmeter (Multimeter) Machine wiring diagram.
INVERTEC V250-S
F-40
4. Put the Output Control R3 at the minimum position. 5. Locate and familiarize yourself with the capacitor test locations on the power board. See Figure F.12.
Note: This test should only be conducted with the V250-S reconnect switch and A jumper configured for 380VAC and above.
201 204
207A
+
202A
DANGER
HIGH VOLTAGE CAN KILL
209 208
203A
+
206
205
F-41
NOTE The following machine parts must be replaced in matched sets If Capacitor C1 is found to be defective, both Capacitors C1 and C2 must be replaced at the same time:
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-42
NOTES
INVERTEC V250-S
F-42
F-43
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
MATERIALS NEEDED
Small needle-nose pliers Small screwdriver 5/16 nut-driver Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC
INVERTEC V250-S
F-44
J1
J2
J5
J3
J4
G2666-[ ]
V250S CONTROL
F-45
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
MATERIALS NEEDED
5/16 nut-driver 1/4 nut-driver 7/16 wrench 3/16 Allen type wrench Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC
INVERTEC V250-S
F-46
4. Carefully remove leads (with pushon connectors) #201, #204, #205, #208, and #209 from the power board.
201 204
Return to Section TOC Return to Master TOC
207A
+
202A
J6
209
Return to Section TOC Return to Master TOC
208
203A
+
206
205
F-47
POWER BOARD REPLACEMENT PROCEDURE 10. Apply a thin coat of Dow Corning 340 heat sink compound (Lincoln E1868) to the filter capacitor terminals. Do not apply to screw threads or threaded area of terminals. 11. When replacing the power board apply a thin coating (.005 to .010) of Dow Corning 340 heat sink compound (Lincoln E1868) to the mating surfaces between the IGBTs and the aluminum heat sink. Compound is NOT permitted on the screw heads or mounting hole threads. The mating surfaces must be clean and free of any foreign material. 12. Install the power board and tighten the four cap head screws. Torque the cap head screws to 40 to 48 IN. Lbs. Note: Before tightening make certain the capacitor terminals are aligned with their respective holes in the power P.C. board.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-48
NOTES
INVERTEC V250-S
F-48
F-49
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
MATERIALS NEEDED
5/16 nut-driver Slot head screwdriver
MATCHED PARTS The following machine parts must be replaced in matched sets If Capacitor C1 is found to be defective, both Capacitors C1 and C2 must be replaced at the same time:
INVERTEC V250-S
F-50
POWER BOARD
Return to Section TOC Return to Master TOC
INVERTEC V250-S
F-51
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-52
NOTES
INVERTEC V250-S
F-52
F-53
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
MATERIALS NEEDED
3/16 Allen type wrench Phillips head screwdriver 7/16 Box wrench Torque wrench Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC
INVERTEC V250-S
F-54
#207 #207A
A B C
#209
Figure F.16 Input Rectifier Lead Locations
INVERTEC V250-S
F-55
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-56
NOTES
INVERTEC V250-S
F-56
F-57
_____________________________________________________________
MATERIALS NEEDED
Slot head screwdriver 5/16 nut-driver 7/16 wrench Wire cutters 3/8 wrench
INVERTEC V250-S
F-58
4. Cut the necessary wire ties and slide the sleeving from the four wire connections to be disassembled. See Figure F.17 5. Label the leads for identification purposes for reassembly.
SLEEVED SPLICES
Figure F.17 Output Diode Assembly and Leads
INVERTEC V250-S
F-59
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-60
NOTES
INVERTEC V250-S
F-60
F-61
_____________________________________________________________
MATERIALS NEEDED
7/16 wrench 1/8 Allen type wrench Torque wrench Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC
INVERTEC V250-S
F-62
DIODE MODULES
F-63
9. To install the new module first make sure the heat sink surface is clean and free of dirt. 10. Apply a thin even coating (.004 to .010 IN.) of thermal compound Penetrox A13 (Lincoln E2529) to the bottom surface of the base plate. Keep the compound away from the mounting hole areas. 11. Apply a small amount of Loctite #271 (Lincoln E1777-1) to the first three threads of the socket head cap screw.
12. Start threading the top and bottom screws and associated washers by hand. Also start the center socket head cap screw and associated washer.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-64
NOTES
INVERTEC V250-S
F-64
F-65
_____________________________________________________________
MATERIALS NEEDED
7/16 Wrench 3/8 Wrench Wire cutters 3/4 Wrench Slot head screwdriver
INVERTEC V250-S
F-66
4. Disconnect transformer primary leads #201, #204, #205 and #208 from the power board. Note: Leads #204 and #205 will have to be removed from the T3 current transformer. Cut any necessary
201 204
Return to Section TOC Return to Master TOC
MAIN TRANSFORMER
Figure F.20 Main Transformer Right Side
INVERTEC V250-S
F-67
INVERTEC V250-S
F-68
INVERTEC V250-S
F-69
25. Connect primary leads #201, #204, #205 and #208 to the power board. Be sure leads #204 and #205 are routed through the current transformer (T3) in the correct manner. Secure leads with cable ties. 26. Clear all leads and secure for case wrap-around assembly.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-70
NOTES
INVERTEC V250-S
F-70
F-71
_____________________________________________________________
MATERIALS NEEDED
7/16 Wrench 3/8 Wrench Wire cutters 3/4 Wrench Slot head screwdriver
INVERTEC V250-S
F-72
4. Disconnect transformer primary leads #201, #204, #205 and #208 from the power board. NOTE: Leads #204 and #205 will have to be removed from the T3 cur-
201 204
Return to Section TOC Return to Master TOC
MAIN TRANSFORMER
Figure F.23 Main Transformer Right Side
INVERTEC V250-S
F-73
INVERTEC V250-S
F-74
INVERTEC V250-S
F-75
26. Clear all leads and secure for case wrap-around assembly.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-76
NOTES
INVERTEC V250-S
F-76
F-77
Should a machine under test be rejected for any reason requiring the removal of any mechanical part that could affect the machines electrical characteristics, or if any electrical components are repaired or replaced, the machine must be retested.
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-78
NOTES
INVERTEC V250-S
F-78
G-1
Return to Master TOC
ELECTRICAL DIAGRAMS
Electrical Diagram Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section G Wiring Diagram (Codes 10102, 10103) . . . . . . . . . . . . . . . . . . . . . . . . . . . G-2 Wiring Diagram (Codes 10187, 10188) . . . . . . . . . . . . . . . . . . . . . . . . . . . G-3 Control PC Board (G2666) Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G-4 Power PC Board (G2684) Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G-5 Control PC Board (G2666) Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . G-6 Power PC Board (G2684) Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . G-7
G-1
INVERTEC V250-S
Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC
NOTES
INVERTEC V250-S
G-2
Return to Section TOC Return to Master TOC
ELECTRICAL DIAGRAMS
L2 RIGHT S F
10 R2 .001/400 2W
G-2
204 206
N.C. C1
1600/450
BACK OUTSIDE
+ ARC
TP5 C5 229 TP6
206
204
204 I
FRONT INSIDE
203A
201
201
201
D5, D6, D7
S F F
TP4
C6
POWER BOARD
205
205 Y
T3 CURRENT TRANSFORMER
205 Y I
FRONT OUTSIDE
S FRONT F S
315 316
- ARC
CC SOFT S2 CC GTAW CC CRISP MODE SWITCH 3
S S
S1 POWER OFF ON H1 H1
207
C2
1600/450
202A
BACK INSIDE
FRONT AUX.
1 6 7 4 2 8 3 5 J2
J4
2 1 1 2 3 4 5 6
W B 375 377 324 376 330 321 303 305 304 327 328 229 319
TP1
D9
B G
317 R R
4 3 1
J1
9 10 11 12 13
J5 6
R3
FAN
H1 H3
MOTORS
315 317
J7 H1 1 H1
R6
R4
R5
200208V 220H3
H2
H3
230V 380415V
H4
440460V
H5
N.C.
NOTES: N.A. 1. FOR MACHINES SUPPLIED WITH INPUT CABLE FOR SINGLE PHASE INPUT: CONNECT GREEN LEAD TO GROUND PER NATIONAL ELECTRIC CODE. CONNECT BLACK & WHITE LEADS TO SUPPLY CIRCUIT. WRAP RED LEAD WITH TAPE TO PROVIDE 600V. INSULATION. FOR THREE PHASE INPUT: CONNECT GREEN LEAD TO GROUND PER NATIONAL ELECTRIC CODE. CONNECT BLACK, RED & WHITE LEADS TO SUPPLY CIRCUIT. 2. FOR MACHINES NOT SUPPLIED WITH INPUT CABLE FOR SINGLE PHASE INPUT: GROUND MACHINE PER NATIONAL AND LOCAL ELECTRICAL CODES. CONNECT TERMINALS U & W TO SUPPLY CIRCUIT. FOR THREE PHASE INPUT: GROUND MACHINE PER NATIONAL AND LOCAL ELECTRICAL CODES. CONNECT TERMINALS U, V & W TO SUPPLY CIRCUIT. N.B. SINCE COMPONENTS OR CIRCUITRY OF A PRINTED CIRCUIT BOARD MAY CHANGE WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY HAVING A COMMON CODE NUMBER.
CONNECTOR CAVITY NUMBERING SEQUENCE (VIEWED FROM COMPONENT SIDE OF BOARD)
N.C. PLACE "A" LEAD ON APPROPRIATE CONNECTION FOR INPUT VOLTAGE. CONNECTION SHOWN IS FOR 440-460V OPERATION. N.D. D2 THRU D4 OUTPUT DIODES ARE A MATCHED SET. D5 THRU D7 OUTPUT DIODES ARE A MATCHED SET. N.E. C1, C2 CAPACITORS ARE A MATCHED SET.
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine. INVERTEC V250S
V
TP2 TP3
INPUT BRIDGE J6
4 2 3 6 5
207A
207A
208
1 2 3 4 5 6
208
F S L1 LEFT F
303A 330
REMOTE LOCAL
S3 LOCAL/REMOTE SWITCH
T1 MAIN TRANSFORMER
209 209
316
J3
7 8
377
CW (MAX) 10K 2W
R3 OUTPUT CONTROL
CONTROL BOARD
14
CW (MAX) 10K 2W
4 2 5
100
H2 R H3 18V R H4
5W
322 318
75 76 77
375B
H5 T2 AUXILIARY TRANSFORMER
J2
J4
J1
J5, J6, J7
J3
321
+ THERMAL
Y
319
OVERLOAD INDICATOR
322 318
D E C B A F MIN 75 76 77 GND
2 4
75
COLOR CODE: B = BLACK G = GREEN R = RED W = WHITE Y = YELLOW
76 77 G
8-5-94 L9280
G-3
Return to Section TOC Return to Master TOC
ELECTRICAL DIAGRAMS
G-3
204 206
N.C. C1
1600/450
BACK OUTSIDE
+ ARC
TP5 C5 229
D2B
206
204
204 I
FRONT INSIDE
TP6 TP4 C6
203A
201
201
201
S F F
POWER BOARD
205
205 Y
T3 CURRENT TRANSFORMER
205 Y I
FRONT OUTSIDE
SHUNT F S FRONT F
D2A
317 320
- ARC
CC SOFT S2 CC GTAW CC CRISP MODE SWITCH 3
S S
S1 POWER OFF W U ON H1 H1
207
C2
1600/450
202A
BACK INSIDE
FRONT AUX.
1 6 7 4 2 8 3 5 J2
J4
2 1 1 2 3 4 5 6
W B 375 377 324 376 330 321 303 305 304 327 328 229 319
TP1
D9
B G
318
POWER BOARD HEATSINK
317 R R
4 3 1
J1
9 10 11 12 13
J5 6
R3
FAN
H1 H3
MOTORS
R4
H1
R5
200208V 220H3
H2
H3
230V 380415V
H4
440460V
H5
N.C.
NOTES: N.A. 1. FOR MACHINES SUPPLIED WITH INPUT CABLE FOR SINGLE PHASE INPUT: CONNECT GREEN LEAD TO GROUND PER NATIONAL ELECTRIC CODE. CONNECT BLACK & WHITE LEADS TO SUPPLY CIRCUIT. WRAP RED LEAD WITH TAPE TO PROVIDE 600V. INSULATION. FOR THREE PHASE INPUT: CONNECT GREEN LEAD TO GROUND PER NATIONAL ELECTRIC CODE. CONNECT BLACK, RED & WHITE LEADS TO SUPPLY CIRCUIT. 2. FOR MACHINES NOT SUPPLIED WITH INPUT CABLE FOR SINGLE PHASE INPUT: GROUND MACHINE PER NATIONAL AND LOCAL ELECTRICAL CODES. CONNECT TERMINALS U & W TO SUPPLY CIRCUIT. FOR THREE PHASE INPUT: GROUND MACHINE PER NATIONAL AND LOCAL ELECTRICAL CODES. CONNECT TERMINALS U, V & W TO SUPPLY CIRCUIT. N.B. SINCE COMPONENTS OR CIRCUITRY OF A PRINTED CIRCUIT BOARD MAY CHANGE WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY HAVING A COMMON CODE NUMBER. 319
CONNECTOR CAVITY NUMBERING SEQUENCE (VIEWED FROM COMPONENT SIDE OF BOARD)
N.C. PLACE "A" LEAD ON APPROPRIATE CONNECTION FOR INPUT VOLTAGE. CONNECTION SHOWN IS FOR 440-460V OPERATION. N.D. D2 THRU D4 OUTPUT DIODES ARE A MATCHED SET. D5 THRU D7 OUTPUT DIODES ARE A MATCHED SET. N.E. C1, C2 CAPACITORS ARE A MATCHED SET.
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine. INVERTEC V250S
V
TP2 TP3
INPUT BRIDGE J6
J7 1 4 2 3 6 5
207A
207A
208
1 2 3 4 5 6
208
F S L1 LEFT F
10 2W
303A 330
D1B
REMOTE LOCAL
S3 LOCAL/REMOTE SWITCH
T1 MAIN TRANSFORMER
320
OUTPUT RECTIFIER HEATSINK
209 209
318
316
J3
7 8
377
CW (MAX) 10K 2W
R3 OUTPUT CONTROL
316
CONTROL BOARD
14
CW (MAX) 10K 2W
1 H1
4 2 5
H2 R H3 18V R H4
322 318
75 76 77
375B
H5 T2 AUXILIARY TRANSFORMER
J2
J4
J1
J5, J6, J7
J3
321
+ THERMAL
OVERLOAD INDICATOR
322 318
D E C B A F MIN 75 76 77 GND
2 4
75
COLOR CODE: B = BLACK G = GREEN R = RED W = WHITE Y = YELLOW
76 77 G
9-29-95E L9907
G-4
Return to Section TOC Return to Master TOC
ELECTRICAL DIAGRAMS
G-4
ITEM
REQ'D
PART NO.
IDENTIFICATION
G2666
C43
DZ10
R88
R90
R89
R91
D40
D36
D41
R100
C47
C48
R94
R95
R97
R96
R99
R34
R102
R101
R103
R85
R117
X9 D34
D33
DZ11
C46
C36
D37
R73
R74
R75
R92
R76
R93
R77
D38
C38
D43
R79
R80
R64
X8
J3
R119
C29 C28 C40 R61
C31
C32
R78
R108
D39
D42
D31
R67
R52
R65
R66
R53
R68
R81
R113
R115
R122 R111
C30
R54
D30
R87
R57
R58
R48
D23
D5
C26
D20
D24
R49
DZ8
R123
R126
R125
R127
R112
R32
Q3
D15 D16 D21
Q4
R39
Q6
D26
D11
D13
R47
D17
D18
D19
C35
C22
R42
R22
R40
Q2
C25
C23
C1
R60 R46
D14
R33
R2
D12
R128
DZ12
Q7
R45
R129 R130
DZ9
D45
D22
D32
R31
R51
C21
R35
DZ1
R23
R29
R24
R4
C15
C16
C14
C45
C17
C18
C19
R17
R18
R19
R20
R21
R41
J5
C12
R5
Q1
X4
X5
DZ4 C11
DZ5
J2
C9
C20 D8
DZ3
X3
C10
R10 R12
R16
R7
R8
C7
R9 C6 C5
R11
D6
C4
C2
X2 DZ2
J1
D2
TP1
D4
D1
D3
R1
C3
V250S CONTROL
R13
R15
R14
C8
X1
R38
R6
C49
DZ7
D9
C24
R36
R37
D46
R55
R30
C27
R114
R3
D44
R69
D27
R62
R82
D28
X7
X6
Q5
C39
R59
R43
R109
R105
J4
C44
R104
G2666
C51
R86
C50
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result INVERTEC V250S in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
G-5
Return to Section TOC Return to Master TOC
ELECTRICAL DIAGRAMS
G-5
G2684
ITEM
REQ'D
PART NO
IDENTIFICATION
B209
B201
B204
B208
B205
J6
D7 R78 C10 R61
OCI2
CR1
T1
R60
R58
R59
D4
R72 R55 D3
D5
R10
R53
R52
C3
R13
X2
R11
R56 R35
R40 D2
C7
X1 R15 R75 R18
R12
R26
R14
R34
R36
R39
R27
DZ15
R77
B207A
R31
C9
C6 R32
OCI1
R48 D10
DZ4
Q1
D9 B203A
DZ11
R45 R44 R43 R42
DZ5
R20
A1
R25
A2
DZ6
C5 R24 R23 R22 R21
C8
DZ10
D11
R46 R41
G2684
B202A
B206
DZ9
DZ7
D8
DZ14
R66 R65
DZ1
R1 R6
V25OS POWER
C12
C2
DZ2
C1 R5 R4 R3 R2
R29
R30
R7
R8
R68 R69
DZ13
R67 R62
DZ12
DZ3
CAPACITORS = MFD/VOLTS
RESISTORS = OHMS
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result INVERTEC V250S in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
G-6
Return to Section TOC Return to Master TOC
ELECTRICAL DIAGRAMS
G-6
R128
33.2K
C23 .1 50V
R8
R130
1.00K
R106
R66
R10
10 8
50V 15J
R12
R129
33.2K
R16
R108
R44
50V
D10 1 SET RESET IN 1 OUT 1 OUT 2 8 BY-PASS CLOCK INH X5
R11
R107
R37
D C B A
J2
R35 47.5K
6 7 8
11 10 9
J5
1
4536B Q4
R51
V SS
2 4
2700p 50V
4
R91 J4 56.2K R89 2.94K R104 100 C51 .1 50V R90 2.94K
12 13
Vi
R6
14
SHUNT +
D9
R4
1.50K
R26
26.7
R24
SHUNT AMPLIFIER
R40
C44
TEST PT D
J5
J4
X9
26.7
26.7
D16 1N4936
TEST PT B
R21
R88
56.2K
47.5K
.1 50V
X9
3
R55
Vi
R105 C42
10K
O.C.V.
R69 100K
13 14
HOLD DOWN
Q2 R56 100K 600mA 40V 33.2K 10K C17 1.8 20V
Vref
D31
X8
12
R20
R68
R42
50V
2.21K
26.7K
R54
.1
R83
+15V
D21
C41
R38
MAX
3 CW
J3
R39 1.50K
+15V
Q6 600mA 40V R87 100K C25 100 20V D30 R78 3.32K
R18
8.25K
R72
50K
R13
R14
CONTROL
75VDC OCV
R17
2.67K
STRIKE
26.7K
Vref
D20 D28
8
8.25K
R71
X7 D
CW 6
R53
crisp
4.75K
C29
R61
.022 50V
47.5K
R77
D19 R113 J3
2
47.5
soft
R80
+15V
R100
CW
D42
4
J3
10K
J3
47.5 J5
3 t
o
Vi
R93 33.2K
R97
R115
56 LOCAL
5
DZ10 5.1V 1W
R95
R46
J3 C40
X6
R82
soft
D24
SPDT-Center off J3
9
4.75K
R79
MODE
SWITCH
REMOTE
.022 50V
R76
J3
R102
100
crisp
D44
R59 10K
13.7K
R43
crisp
TIG
J3
R86
+15V
77 75
J5
5 t
o
+15V
R45 J5 56
D39
76
6 t
o
X7
R60 56
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result INVERTEC V250S in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
50V
12
+15V
G
PRECHARGE TIMER +15V
DZ12 12V 1W R48 Q3 600mA 40V R41 1.00K D11 D12 47.5 4.75K 221 D13 R23 33.2K DZ5 15V 1W
1
2665
+15V
+15V
R28 10.0
D
J2 J2
Q1
+t
DZ3 20V 1W J1
D3 D2
100K R1 1.0 5W
IN D6
.24
F J2
4
VS IN NC GND X2
8 7 6 5
+15V
D46
Q7 600mA 40V J1
18VAC
1.50K X8 R34 J3
6 3
X1 LM350
OUT
2 3 4
D8 1.0A 30V
TP1
C2 3300 50V C3
243
ADJ
TSC4429JJA
TO PULSE TRANSFORMER
C12 15.0K .1
THERMOSTATS
J1
10K
R65 33.2K
(+) Y
D4
D1
2.67K
1 2 3 4
VS IN NC GND X4
8 7 6 5
J2
2
V DD
MONO IN OSC INH DECODE
16 15 14 13
THERMAL LIGHT
2 3 4
+15V
13
J3
12V
TSC4429JJA
D7 1.0A 30V
R5
56
D23
D32 D22
D45
DZ8 75V 1W
D5
13
X6
12
R2 332K C1 .1
C49 .1 50V
crisp
11
X6
10
R49 10K
500mA 300V
100K
TRIGGER INTERFACE
50V
D17 J2 C24 .15 100V 1N4936 1 1/2W C22 .022 D18 1N4936 26.7 D15 R27 R25 1N4936 50V R33 2.21K
+15V D14
56
Vref
C33 .022 50 V
Test Pt A
C18 1.8
18.2K
R84 47.5K
X3
16 15 14 13 12 11 10 9
+15V
C9 4.7 35V C39 .022 50V
J3
12
+ ARC
R112 562 R121 22.1K 56.2K C45 47p 100V C14 150p 50V
SG3847
PWM CONTROL
SHORTING
D27 J3
10
10K
11
DETECTOR
J3 R70 3.32K
3 8
X9
10
6.19K
DZ9 10V 1W
X6
soft
TEST PT E
R73 10K R81 D38 1.00K 2.21K
82.5K
Vref crisp
11 12
100V
X7 C
10
R52 332K
Vi OVERCURRENT FOLDBACK
100K
X7
13
X8
5
D41
Vref
C46 150p
35V
Vref
6.19K
100V X9
7
R94 33.2K
R103
Vi Vref
47.5K X8
1
R64
R98 100K
SD'
X6
D43
SOFT SCRATCH
X6 HEXTRGR C8 .022 50V
7
GENERAL INFORMATION
ELECTRICAL SYMBOLS PER E1537 CAPACITORS = M F D ( .022/50V 1/4W UNLESS OTHERWISE SPECIFIED) UNLESS OTHERWISE SPECIFIED) RESISTORS = Ohms ( DIODES = 1A, 400V
X8 LM224
11
X9 LT1014
11
X7 4066B
7
X5 4536B
8
X6
LABELS
D-
SUPPLY
VOLTAGE NET
NOTES :
N.A. SINCE COMPONENTS OR CIRCUITRY ON A PRINTED CIRCUIT BOARD MAY CHANGE WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE NUMBER.
UNLESS OTHERWISE SPECIFIED TOLERANCE ON HOLES SIZES PER E-2056 ON 2 PLACE DECIMALS IS + .O2 ON 3 PLACE DECIMALS IS + .OO2 ON ALL ANGLES IS + .5 OF A DEGREE MATERIAL TOLERANCE ("t") TO AGREE WITH PUBLISHED STANDARDS Ch'ge.Sht.No.
2665
G-7
Return to Section TOC Return to Master TOC
ELECTRICAL DIAGRAMS
L9304_1BA
G-7
11
78
12
C-
D-
R-
13
CR1
2 D7 1
11
X2
14
INPUT RECTIFIER
R14 150K
J6
3
LABELS
SUPPLY
CR1 R1 10.0 DZ1 6.2V 1W DZ2 15V 1W 1.00K 1.00K 1.00K 1.00K R6 10.0
3 G
TYPE
S 1
R7
D8 1A 1000V
2.7 5W
4A 900V
12V 1W
R2
R4
R5
R3
C1 .0047 50V
DZ3 15V 1W
R19
SCALE
MATERIAL TOLERANCE ("t") TO AGREE
BYT12P600
TRANSFORMER PRIMARY
R29 R30 2500 5W 2500 5W +15V
GENERAL INFORMATION
1/4W
205
M F D ( .022/50V
R32
5W +15V
R35
150K
R37
2500
R40 332K
5
A1
6
R76
10.0 DZ5 6.2V R25 1W DZ6 15V 1W 1.00K 1.00K 1.00K 10.0 C5 .0047 50V
10 G D
D3
R36
A1
APT6035N
S
X1 TL431 6
C7 27 35V 6.19K
SINCE COMPONENTS OR CIRCUITRY ON A PRINTED CIRCUIT BOARD MAY CHANGE
REF
1A 1000V
2.7
5W
R22
R24
R23
R21
1.00K
DZ7
G1
R26
2.7 5W
T1
8 3
15V 1W
GATE
S1 G2
203A RECONNECT
GATE
10 S2 4
J6
DRIVE
12
S3
GATE
9
G3 S4
10.0 R41
202A
B
2 D
R46 10.0
APT6035N
R47
D10 1A 1000V
5W
R42
R44
R45
R43
.0047 50V
15V 1W
C9 .0047 1000V
+15V
OVERVOLTAGE
+15V
BYT12P600
PRIMARY
R71 2500 5W
BLEEDER
R52
R56 332K
R59
204 TRANSFORMER
RESISTORS
2500
PROTECTION
10K
10
X2 X2
1 9
R72
A2
4 7
R60
5W
R51 150K
D5 3.32K
J6
R55
BYT12P600
325VDC (NOMINAL)
FILTER
R50
R58
D4
15.0K
R57
CAPACITOR
2500
150K
10K
2 6 4
OCI2
CNY17-3V
R73
A2
6
5W
A
9 D 10
R74
A2
G
PRIMARY
2500 5W
681K
R61
201 TRANSFORMER
R67 10.0
APT6035N
S 8
D11 1A
2.7
5W
R64
R65
R66
R63
DZ14
15V 1W
5W
R77
50V
R68
.0047
1000V
2.7
1.82K
DZ15 15V 1W
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result INVERTEC V250S in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
N.A.
DZ11
NOTES :
NUMBER.
2.7
6.2V
2.7
5W
CONTROL
GATE
7
R48
G4
A2
FROM
RECONNECT
Ch'ge.Sht.No.
J6
R39
562
16.5K
R20
2.8K
X2
6
NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE
R75
DR.
BYT12P600
325VDC (NOMINAL)
FILTER CAPACITOR
RESISTORS
15.0K
D2
LC
BLEEDER
R34
R31
150K
DIODES =
2500 5W
CAPACITORS =
A1
RESISTORS = Ohms (
1A, 400V
DATE
8-23-93
1000V
50V
NONE
.0047
.022
267K
C2
C4
CHK.
APT6035N
2.7
5W
100 Q1 DZ4
OCI1
1.82K
CNY17-3V
F.V.
R8
EQUIP.
A1
R17
R18
R12
100 10W
R16
CAPACITOR PRECHARGE
SUP'S'D'G.
SHT. NO.
DZ-
X-
LM224
12
FRAME CONNECTION
Q- 1
COMMON CONNECTION
15
X2
V250-S POWER
VOLTAGE NET
C3
(RELAY DRIVE)
L 9304