You are on page 1of 14

PCRPH1307aprv

Warning

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.

MULTI-SPLIT TYPE AIR CONDITIONERS


One air-conditioning system, five individually designed interiors

Connect up to 5 indoor units to a single outdoor unit


Specifications, designs and other content appearing in this brochure are current as of January 2013 but subject to change without notice.
c All rights reserved

Cooling Only [60 Hz]

Air condition multiple rooms in your home with a single outdoor unit
If you would like your conditioners to match your personal dcor

If you wish to make more effective use of the space on your balcony

If you want your family to be comfortable in every room of your home

Contents

Multi-Split Type is the knowledgeable choice.


The Daikin Multi-Split Type lets you build a highly efficient multi room air conditioning system by connecting up to five indoor units to a single outdoor unit. The series includes a wide variety of indoor units, so it is easy to select a model that blends in unobtrusively. A single compact outdoor unit allows you to make more efficient use of available space in the installation location, such as a balcony. The individual indoor units in different roomsthe living room, study, and bedrooms, for examplecan be controlled independently to match your familys lifestyle. The Daikin Multi-Split Type makes your home more comfortable and stylish at the same time.

3 5 9 15 19 20 21

Concepts Main features Product lineup Functions Specifications Options Capacity tables

Enjoy the comfort and luxury of your dreams.

In 1969, Daikin developed the first multi room air conditioning system in Japan that needed just one outdoor unit. Over the ensuing 40 years, Daikin has built an enviable reputation with the constant progress of its technology. Daikin Multi-Split Type requires only a single outdoor unit to maintain comfort in up to five rooms. Where outdoor unit installation space is limited, it is the ideal choice. Air conditioner settings for each room can be controlled individually to suit the preference of each person. While optimising personal comfort, Daikin Multi-Split Type uses DC inverter technology, making it energy efficient.
5MKS series

Up to 5 indoor units can be connected.

Key concepts for Daikin Multi-Split Type

4MKS series

Intelligent technologies
The DC motor, swing compressor and other advanced technologies make for energyefficient operation that achieves high COPs.

Up to 4 indoor units can be connected.


3MKS series

Ideal environment
The quiet operation mode helps create a more pleasant living environment. DC inverter power control provides comfortable temperature control.
Up to 3 indoor units can be connected.

Interior & exterior flexibility


The wide range of indoor unit options provides ample choice. A single compact outdoor unit reduces installation space requirements, while long maximum piping lengths provide flexibility for connections.

Individual control
The individual indoor units in different rooms can be controlled independently. The priority-room setting function lets you specify a room to receive preference in air conditioning operation.

Connect 5 indoor units to a single outdoor unit

Main features
Intelligent technologies

Main features

Product lineup

Functions

Specifications

Options

Capacity table

Ideal environment

High energy efficiency through advanced technologies delivers high COP


High energy efficiency
5MKS110LVM
COP

Convenient features to create your ideal environment


Quiet operation
Indoor unit
Daikin Multi-Split Type offers the quiet sound level of 22 dB (A) during Indoor Unit Quiet Operation of the FTKS25.

What is COP?

3.36

An air conditioner's COP (coefficient of performance) indicates how efficiently it uses energy. A high COP means high energy efficiency.

22 dB (A)

* During rated capacity operation of 5 indoor units (2.5 + 2.5 + 2.5 + 2.5 + 5.0 kW class).

COP =

Capacity (W) Power consumption (W)

2 1

Note: Capacity may decrease when quiet functions are selected.

22 dB (A) is so quiet you can even hear whispers


Rustling of leaves Library

20

30

40

50

(dB(A))

Daikin energy-saving technologies


1
Swing compressor
Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation.
Swing compressor

Pendulum of a wall clock

Normal office

Based on Examples of Sound Levels, Ministry of the Environment, Japan, November 12, 2002

Outdoor unit
Swing bush Refrigerant gas

Daikin Multi-Split Type achieves a quiet sound level of 43 dB (A) during Outdoor Unit Quiet Operation or Night Quiet Mode of the 3MKS58.
Note: Capacity may decrease when quiet functions are selected.

Integral piston of blade and roller


The swing compressor can reduce operational vibration and sound because its piston moves smoothly inside the compressor.

Reluctance DC motor

Comfortable temperature control


Inverter air conditioners finely adjust capacity according to changes in the air-conditioning load and the difference between the indoor temperature and set temperature is small. These give higher comfort levels than with noninverter air conditioners.
Temp.

Reluctance DC motor
Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and reluctance torque*2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor.
Neodymium magnets are used in the pink-coloured area. *1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet. *2. The torque created by the change in power between the iron and magnet parts.
Small load Low capacity
90

Large load High capacity

Non-inverter type
Not cool

Reluctance DC Motor

DC inverter type
Set temp.

Motor efficiency (%)

80

Conventional DC motor
70

More than 20%


AC motor

During cooling operation


Time

60

Too cool

50 0 30 60 90 120

* This diagram is a representation for illustrative purpose only.


Rotational speed (rps)
Starts

Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory.

PAM control
Pulse Amplitude Modulation (PAM) control reduces energy loss by controlling the amount of switching on/off of the converter.
Power factor Converter efficiency

Inverter efficiency

Power

Power supply

Loss

Loss

Main features
Interior & exterior flexibility

Main features

Product lineup

Functions

Specifications

Options

Capacity table

Individual control

Wide array of choices to match your interior


Stylish indoor units for elegant interiors

Individual control for each room to match your familys lifestyle


Preferential air conditioning

Initial setting required during installation

Priority-Room Setting delivers priority capacity to a prioritised room when using multi-split air conditioners. After a priority room is selected, it receives preferential air-conditioning plus priority control over the 2 functions below.

1 Priority setting with Inverter Powerful Operation


When Inverter Powerful Operation is selected in the priority room, the indoor unit capacity in the priority room is increased by shifting capacity from units in other rooms. After 20 minutes, all units automatically return to their original settings.
Note: Capacity in other rooms may decrease slightly.

Room A Room B

Room A Room B

Power Up!

Priority room
Living room Room C

Priority room
Living room Room C

Compact outdoor units for a less obtrusive exterior look


The system requires only a single outdoor unit. The compact design provides installation flexibility and takes up less space, for a less obtrusive exterior look.

2 Priority setting with Outdoor Unit Quiet Operation


Priority-Room Setting also allows Outdoor Unit Quiet Operation to be selected by one command* from the priority room.
* If Priority-Room Setting has not been set, the Outdoor Unit Quiet Operation button must be pushed on the wireless remote controller of all indoor units operating at that time.

Convenient remote controllers


A variety of convenient controller systems permit individual control of settings such as temperature, airflow volume, and operation duration.

Long piping lengths for installation flexibility


The ample maximum piping length of 80 m permits more freedom in the placement of air conditioner units and facilitates the optimisation of interior space.
Model name Max. piping length Total For one room 3MKS58 50 m 3MKS75 60 m 25 m 4MKS80 4MKS100 70 m 5MKS110 80 m 30 m

Wireless remote controller

5-room centralised controller (option)

Central remote controller (option)

Unified on/off controller (option)

Product lineup

Main features

Product lineup

Functions

Specifications

Options

Capacity table

A wide range of models to choose from that deliver comfort and convenience
Outdoor units
Connect up to 3 indoor units Connect up to 4 indoor units Connect up to 5 indoor units

An array of indoor unit models with innovative and attractive designs make it easy to find the ideal match for each room in your home.

Wall-Mounted Type
An attractive match for large rooms with refined interiors is provided by the stylish flat panel design.

Model name Capacity class Max. piping length Max. height difference

3MKS58KVM

3MKS75KVM

4MKS80KVM

4MKS100KVM

5MKS110LVM

5.8 kW 50 m 15 m

7.5 kW 60 m 15 m

8.0 kW 70 m 15 m

10.0 kW 70 m 15 m

11.0 kW 80 m 15 m

Indoor units
Wall-mounted type
Capacity class

Duct-connected type

Compact multi flow ceilingmounted cassette type

Option

2.5 kW 3.5 kW 5.0 kW 6.0 kW 7.1 kW

FTKS25KVM FTKS35KVM FTKS50KVM FTKS60KVM FTKS71KVM

CDKS25KVM CDKS35KVM CDKS50KVM CDKS60KVM

FFQ25KVL FFQ35KVL FFQ50KVL FFQ60KVL

Duct-Connected Type
Fits in shallow ceiling recesses only 240 mm deep thanks to the new slim and compact design.

Indoor unit connectivity with each outdoor unit


Indoor unit

Wall-mounted type

Duct-connected type

Compact multi flow ceilingmounted cassette type

Outdoor unit

2.5 kW

3.5 kW

5.0 kW

6.0 kW

7.1 kW

2.5 kW

3.5 kW

5.0 kW

6.0 kW

2.5 kW

3.5 kW

5.0 kW

6.0 kW

3MKS58KVM 3MKS75KVM 4MKS80KVM 4MKS100KVM 5MKS110LVM


Note: For information regarding specific possible connection combinations, please contact your local dealer.

Compact Multi Flow Ceiling-Mounted Cassette Type


The compact and flexible design is suited to commercial spaces such as offices.

10

Indoor unit lineup

Main features

Product lineup

Functions

Specifications

Options

Capacity table

Wall-Mounted Type

Duct-Connected Type

2.5 kW class
CDKS25KVM

3.5 kW class
CDKS35KVM

5.0 kW class
CDKS50KVM

6.0 kW class
CDKS60KVM

700 mm width type

900/1,100 mm width type

Slim and compact design


Models in the CDKS25/35K series are only 700 mm in width and 21 kg in weight, so are easily installed in limited spaces. Just 200 mm in height, all models can be installed in rooms with as little as 240 mm depth between the drop ceiling and ceiling slab, making them ideal for even shallow ceilings.
CDKS25/35K

Quiet operation
Quiet operation sound level of only 29 dB (A) is achieved for 2.5 and 3.5 kW class models.

2.5 kW class
FTKS25KVM

3.5 kW class
FTKS35KVM

5.0 kW class
FTKS50KVM

6.0 kW class
FTKS60KVM

7.1 kW class
FTKS71KVM

Suspension bolt*

200 mm Only 700 mm


240 mm

Air discharge duct* Air discharge grille*

Suction duct*

Air filter

AIR
Chamber

Evenly distributed air


Vertical and horizontal airflow is controlled by Power-Airflow Dual Flaps and WideAngle Louvers working in tandem, realising even distribution of air.

3-D airflow
3-D Airflow combines Vertical and Horizontal AutoSwing to circulate air to every part of a room for uniform cooling of even large spaces.
Dimensions (H x W x D) Weight Airflow rate (H) External static pressure
Signals from the wireless remote controller are transmitted to the signal receiver.

Signal receiver wire Length = 1,900 mm

Air suction grille*

Signal receiver

AIR
* Locally obtained parts

Option

700 mm width type mm kg m3/min (cfm) Pa

CDKS25K 21 8.7 (307) 30 CDKS50K 200 x 900 x 620 27 12.0 (424) 40

CDKS35K
Suction grille (KDGF19A45)

200 x 700 x 620

900/1,100 mm width type


The Power-Airflow Dual Flaps flatten out to deliver air to the farthest corners of the room.

CDKS60K 200 x 1,100 x 620 30 16.0 (565)

Dimensions (H x W x D) Weight Airflow rate (H) External static pressure

mm kg m3/min (cfm) Pa

Notes: 1. To prevent an increase in operation sound, avoid installing the air suction grille directly below the suction chamber. 2. Grilles, piping connections, ducts, and installation parts should be obtained locally. Duct-connected types do not have drain pumps. 3. The signal receiver unit must be located near the air suction inlet, because the unit includes a sensor that detects room temperature.

11

12

Indoor unit lineup

Main features

Product lineup

Functions

Specifications

Options

Capacity table

Compact Multi Flow Ceiling-Mounted Cassette Type


Quiet sound level of only 27 dB (A)
At low fan speeds, the 2.5 kW model produces sound of only 27 dB (A), and even the 6.0 kW model as low as 35 dB (A). This is due to a spiral hub cover that reduces internal airflow resistance.
Wired LCD remote controller Wireless LCD remote controller Signal receiver unit

Programme "Dry"
Programme Dry gives priority to reducing the level of humidity rather than room temperature. Dehumidification is computer controlled to prevent abrupt and uncomfortable changes in air temperature.

Spiral hub cover


(H/L)

Switchable fan speed: High/Low Hot start (after defrost)


Uncomfortable cold air draft is not discharged when heating operation starts or when switching to heat after defrosting.

Wireless remote controller and signal receiver unit are sold as a set.

FFQ25 33/27 dB(A)

FFQ35 36/28 dB(A)

FFQ50 40/30 dB(A)

FFQ60 44/35 dB(A)

Multi-Flow System
Option Option

4-way flow

3-way flow

2-way flow

Provided with drain pump

2.5 kW class
FFQ25KVL

3.5 kW class
FFQ35KVL

5.0 kW class
FFQ50KVL

6.0 kW class
FFQ60KVL
750 mm

1 pattern
" " denotes piping direction. " outlet (option).

4 patterns

1 pattern

Auto-restart
If there is a power failure while the unit is operating, the system will restart in the same mode when power is restored.

" denotes sealing member for air discharge

Low draft performance is designed for your comfort

Designed to fit 600 mm wide ceiling grids


575 mm 575 mm

Note: For 3-way or 2-way flow installation, the sealing member for air discharge outlet (option) must be used to close off the unused outlet(s).

Air discharge patterns can be selected according to installation.

Long-life filter
Maintenance is not required for one year.

Horizontal Flow

286

Ceiling soiling prevention function


act Comp n panel ratio deco

mm

Less draught
700 mm

Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is required less frequently.
Note: Operation sound increases when using 2way or 3-way flow.

Comfortable across all areas


Conditioned air is distributed Adjustable airflow angle to evenly by Auto-swing suit all room conditions. operation.

700 mm

Filter sign
When the filter requires cleaning, the filter icon is displayed on the remote controller.

T-bar grid does not need to be cut


Ceiling panel

Two selectable temperature sensors


Both indoor unit and wired remote controller (option) contain temperature sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature requires initial setting by the installer.
*Temperature sensor on indoor unit must be used when the air conditioner is controlled from another room. (Wireless remote controller does not have a temperature sensor.)

AUTO-SWING
Standard setting
0 60
0

5 directions
Settable to 5 different levels between 0 and 60 60

T bar
600 mm

Auto-swing between 0 and 60

Draft prevention setting


(Set on site)

0 35

600 mm
Settable to 5 different levels between 0 and 35

Auto-swing between 0 and 35

35

Setting to prevent soiling of ceiling


(Set on site)

25

Auto-swing between 25 and 60 60

25 60

Settable to 5 different levels between 25 and 60

Note: Angles shown above are provided as a guide. They may differ depending on the installation site.

Even for modules other than 600 x 600, no inspection opening is required. Maintenance can be performed after simply removing the grille, because the switchbox is built into the unit.

13

14

Functions

Main features

Product lineup

Functions

Specifications

Options

Capacity table

Easy-to-use wireless remote controller

Models
Indoor unit
Wall-mounted type Duct-connected type Compact multi flow ceilingmounted cassette type

Outdoor unit

Functions
Comfortable Airflow
Power-Airflow Dual Flaps Wide-Angle Louvres Vertical Auto-Swing (up and down) Horizontal Auto-Swing (left and right) 3-D Airflow Indoor Unit Quiet Operation Outdoor Unit Quiet Operation Night Quiet Mode Intelligent Eye Programme Dry Function Auto Fan Speed

FTKS25/35K

FTKS50/60/71K

CDKS25/35/50/60K

FFQ25/35/50/60K

FTKS25/35K

FTKS50/60/71K

Sets room temperature Econo Mode Inverter Powerful Operation On/Off Switch Mould-Proof Operation

Vertical Auto-Swing (up and down) Selects fan speed and Indoor Unit Quiet Operation Selects mode: automatic, cooling, dry, fan-only operation Intelligent Eye Outdoor Unit Quiet Operation Cancels On/Off Timer 24-Hour On Timer Sets clock 24-Hour Off Timer and Night Set Mode Sets timer

Sets room temperature On/Off Switch Inverter Powerful Operation Horizontal Auto-Swing (left and right)

Comfort Control Lifestyle Convenience Cleanliness Timers Worry Free

Home Leave Operation

Inverter Powerful Operation Econo Mode Home Leave Operation Indoor Unit On/Off Switch Priority-Room Setting
Titanium Apatite Photocatalytic Air-Purifying Filter

Mould-Proof Operation Wipe-Clean Flat Panel Filter Cleaning Indicator 24-Hour On/Off Timer 72-Hour On/Off Timer Night Set Mode Auto-Restart after Power Failure Self-Diagnosis with Digital Display Anticorrosion Treatment of Outdoor Heat Exchanger Fins

15

16

Functions

Main features

Product lineup

Functions

Specifications

Options

Capacity table

Comfortable Airflow
Power-Airflow Dual Flaps
Power-Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room.

Intelligent Eye
Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by + 2C for energy savings.

Cleanliness
Titanium Apatite Photocatalytic Air-Purifying Filter
This filter combines the Air-Purifying Filter and Titanium Apatite Photocatalytic Deodorising Filter in a single highly effective unit. The filter traps microscopic particles and removes bacteria. It lasts for 3 years without replacement if washed about once every 6 months.

Worry Free
Auto-Restart After Power Failure
The air conditioner memorises the settings for mode, airflow, temperature, etc., and automatically returns to them when power is restored after a power failure.

Wide-Angle Louvres
Smoothly curved Wide-Angle Louvres provide wide airflow coverage for effective cooling.

Programme Dry Function


This function automatically reduces the level of humidity.

Self-Diagnosis with Digital Display


Malfunction codes for each indoor unit are shown on the digital display panel of the wireless remote controller for fast and easy maintenance.

Vertical Auto-Swing (up and down)


Vertical Auto-Swing automatically moves the flaps up and down to provide an even distribution of air throughout a room.

Auto Fan Speed


The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature.

Mould-Proof Operation
Mould-Proof Operation automatically runs fanonly operation for 1 hour when cooling or dry operation is stopped. This airflow prevents the generation of mould and mould odours inside the indoor unit.

Anticorrosion Treatment of Outdoor Heat Exchanger Fins


The outdoor units heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins resistance to acid rain and salt corrosion.

Horizontal Auto-Swing (left and right)


Horizontal Auto-Swing automatically moves the louvres to the left and right to cover a room with cool air.

Lifestyle Convenience
Inverter Powerful Operation
This function is convenient for boosting cooling performance for a 20-minute period both when you first turn on your air conditioner and want to quickly change the room temperature.

Wipe-Clean Flat Panel


The flat panel models can be cleaned with only the single pass of a cloth across their smooth surface. The flat panel can also be easily removed for more thorough cleaning.

3-D Airflow
This function combines Vertical and Horizontal Auto-Swing to circulate a cloud of cool air right to the corners of even large spaces.

Filter Cleaning Indicator


Dust deposited on the air filters is not only unhygienic, it also reduces the operating efficiency of the air conditioner. A message indicates when the air filters need cleaning.

Others Worry Free


Wiring Error Check
Microcomputer checking and diagnosis of wiring errors during installation prevents problems.

Econo Mode
Econo Mode reduces the maximum running current and maximum power consumption of the outdoor unit to the rated values. This is useful when using multiple air conditioners and other electrical devices at the same time.

Comfort Control
Indoor Unit Quiet Operation
Indoor unit operating sound level is decreased by 2 or 3 dB (A) from the low setting fan speed using the wireless remote controller.
See page 6

Home Leave Operation


Home Leave Operation continues operation to prevent a room from becoming too hot while you are sleeping or out of your home. Select any temperature from 18 to 32C for cooling operation.

Timers
24-Hour On/Off Timer
This timer can be preset to start and stop at any time within a 24-hour period. The air conditioner is started/ stopped simply by pressing the On/Off timer button on the wireless remote controller.

Flexibility
Chargeless
Charging with additional refrigerant is not required even for long runs of piping.

Outdoor Unit Quiet Operation


Outdoor unit operating sound level is decreased by 3 dB (A) from the rated operation sound using the wireless remote controller.
See page 6

Either Side Drain (left or right)


The wall-mounted type indoor unit is designed so that drain piping can be connected to either the left or right side.

Indoor Unit On/Off Switch


The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.

72-Hour On/Off Timer


This timer can be set to start and stop at any time within a 72-hour period. Simply press the On timer button, and the air conditioner will automatically start to operate at the preset time.

Night Quiet Mode


Outdoor unit operating sound level is automatically decreased by 3 dB (A) from the rated operation sound when the outdoor temperature has dropped by 6C from the maximum temperature recorded during the daytime. Initial setting is required during installation.
See page 6

Priority-Room Setting
When this function is set, it is convenient for selecting Inverter Powerful Operation and Outdoor Unit Quiet Operation. Initial setting is required during installation.
See page 8

Night Set Mode


Pressing the Off timer button automatically selects the Night Set Mode. This function prevents excessive cooling for pleasant sleep conditions.

Refer to page 16 to check the functions offered by individual models.

17

18

Specifications/Options Specifications Outdoor unit


Model name Power supply Casing colour Compressor type Sound level Cooling Dimensions (H X W X D) Machine weight Operation range Cooling Max. piping length Necessity of additional charge Max. installation height difference 3MKS75KVM 4MKS80KVM 4MKS100KVM 5MKS110LVM 1 phase, 220-240 V/220-230 V, 50/60 Hz Ivory white Hermetically sealed swing type 46 48 48 50 51 735 X 936 X 300 770 X 900 X 320 990 X 940 X 320 49 58 69 83 10 to 46 50 (total) 60 (total) 70 (total) 80 (total) 25 (for one room) 30 (for one room) 20 (for 40m or more) Chargeless 15 (between indoor and outdoor units)/ 15 (between indoor and outdoor units)/ 15 (between indoor units) 7.5 (between indoor units) 3MKS58KVM

Main features

Product lineup

Functions

Specifications

Options

Capacity table

Options Outdoor unit


No. 1 2 Item Air direction adjustment grille Drain plug 3MKS58K 3MKS75K 4MKS80K KPW945A4 KKP937A4*1 4MKS100K KKP945A4*2 5MKS110L KPW5E112
Notes: *1. One set includes 5 pieces for 5 units. *2. One set includes 1 piece for 1 unit.

dB (A) mm kg CDB m g/m m

Indoor unit
No. 1 Item 5-room centralised controller*1 Wiring adaptor for time clock/remote controller*2 (Normal open pulse contact/normal open contact) Titanium apatite photocatalytic air-purifying filter*3 Wireless remote controller loss prevention chain Suction grille Insulation kit for high humidity Wall-mounted type FTKS25/35 FTKS50/60/71 CDKS25/35 KRC72 KRP413AB1S KAF970A46 KAF952B42 KKF917A4 KDT25N32 KDGF19A45 KDT25N50 KDT25N63 Duct-connected type CDKS50 CDKS60 2 3 4 5 6

Measurement conditions 1. Cooling operation data is based on the following conditions :indoor temp.26.7CDB, 19.4CWB; outdoor temp.35CDB; piping length 7.5m. 2. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

Indoor unit
Wall-mounted type
Model name Power supply Casing colour Airflow rate (H) m3/min (cfm) dB (A) Sound level (H/L/SL) Fan speed Temperature control mm Dimensions (H X W X D) kg Machine weight Liquid (flare) Piping mm Gas (flare) connections Drain Heat insulation FTKS25KVM FTKS35KVM FTKS50KVM FTKS60KVM 1 phase, 220-240 V/220-230 V, 50/60 Hz White 8.7 (307) 8.9 (314) 14.7 (519) 16.2 (572) 37/25/22 38/26/23 44/35/32 45/36/33 5 steps, quiet and automatic Microcomputer control 283 X 800 X 195 290 X 1,050 X 238 9 12 6.4 9.5 12.7 18.0 Both liquid and gas pipes FTKS71KVM

Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit. *2. Time clock and other devices should be obtained locally. *3. Filter is a standard accessory. It should be replaced approximately every 3 years.

17.4 (614) 46/37/34

5-room centralised controller KRC72


15.9 No. 1 2 Item Decoration panel Remote controller

Titanium apatite photocatalytic air-purifying filter KAF952B42

Remote controller loss prevention chain KKF917A4

Wired type*1 Wireless type

Duct-connected type
Model name Power supply Airflow rate (H) m3/min (cfm) dB (A) Sound level (H/L/SL)* Fan speed Temperature control Dimensions (H X W X D) mm Machine weight kg Liquid (flare) Piping Gas (flare) mm connections Drain Heat insulation External static pressure Pa CDKS25KVM CDKS35KVM CDKS50KVM 1 phase, 220-240 V/220-230 V, 50/60 Hz 8.7 (307) 12.0 (424) 35/31/29 37/33/31 5 steps, quiet and automatic Microcomputer control 200 X 700 X 620 200 X 900 X 620 21 27 6.4 9.5 VP20 (O.D.26 / I.D.20) Both liquid and gas pipes 30 CDKS60KVM 16.0 (565) 38/34/32

200 X 1,100 X 620 30 12.7

3 4 5 6 7 8 9 10

Adaptor for wiring*2 Wiring adaptor for electrical appendices*2 Installation box for adaptor PCB Remote sensor (for indoor temperature) Replacement long-life filter Fresh air intake kit Direct installation type Sealing member of air discharge outlet Panel spacer

Compact multi flow ceiling-mounted cassette type BYFQ60B8W1 BRC1C61 BRC7E531W KRP1BA57 KRP4AA53 KRP1BA101 KRCS01-1B KAFQ441BA60 KDDQ44XA60 KDBH44BA60 KDBQ44BA60A

Notes: *1. Wiring for wired remote controller should be obtained locally. *2. Installation box for adaptor PCB (KRP1BA101) is necessary.

40

Note: *The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa for CDKS25/35 and 40 Pa for CDKS50/60. Sound level values for bottom-suction operation can be obtained by adding 6 dB(A) for CDKS25/35 and 5 dB(A) for CDKS50/60.

Control system
No. Item Central remote controller* Unified on/off controller* Schedule timer* Interface adaptor for DIII-NET use Wall-mounted type Duct-connected type DCS302CA61 DCS301BA61 DST301BA61 KRP928BB2S DTA112BA51 Compact multi flow ceiling-mounted cassette type 1 2 3 4

Compact multi flow ceiling-mounted cassette type


Model name Power supply m3/min (cfm) Airflow rate (H) dB (A) Sound level (H/L) Fan speed Temperature control mm Dimensions (H X W X D) kg Machine weight Liquid (flare) Piping mm Gas (flare) connections Drain Heat insulation Model Colour Panel (option) Dimensions (H X W X D) mm Weight kg FFQ25KVL 9.0 (318) 33/27 FFQ35KVL FFQ50KVL 1 phase, 220 V, 60 Hz 10.0 (353) 12.0 (424) 36/28 40/30 2 steps Microcomputer control 286 X 575 X 575 17.5 6.4 9.5 VP20 (O.D.26 / I.D.20) Both liquid and gas pipes BYFQ60B8W1 White 55 X 700 X 700 2.7 12.7 FFQ60KVL 15.0 (530) 44/35

Note: *Interface adaptor for DIII-NET use (KRP928BB2S/DTA112BA51) is also required for each indoor unit.

Central remote controller DCS302CA61

Unified on/off controller DCS301BA61

Schedule timer DST301BA61

19

20

Capacity table Capacity table Cooling only


Outdoor unit Combinations of indoor units 25 35 50 25+25 25+35 25+50 35+35 35+50 50+50 25+25+25 25+25+35 25+25+50 25+35+35 25 35 50 60 71 25+25 25+35 25+50 25+60 25+71 35+35 35+50 35+60 35+71 50+50 50+60 50+71 60+60 60+71 25+25+25 25+25+35 25+25+50 25+25+60 25+25+71 25+35+35 25+35+50 25+35+60 25+35+71 25+50+50 25+50+60 35+35+35 35+35+50 35+35+60 35+50+50 Capacity of each indoor unit (kW) A room 2.50 3.50 5.00 2.50 2.18 1.86 2.73 2.39 2.90 1.86 1.71 1.45 1.52 2.50 3.50 5.00 6.00 7.10 2.50 2.50 2.30 2.12 1.95 3.50 2.96 2.76 2.48 3.75 3.41 3.10 3.75 3.44 2.30 2.12 1.88 1.70 1.55 1.98 1.70 1.56 1.43 1.50 1.39 2.50 2.19 2.02 1.94 B room C room D room Total capacity (kW) Rated (Min.-Max.) 2.50 (1.763.30) 3.50 (1.764.56) 5.00 (1.855.82) 5.00 (1.886.23) 5.23 (1.886.35) 5.57 (1.886.91) 5.46 (1.886.40) 5.80 (1.886.92) 5.80 (1.837.00) 5.58 (1.957.04) 5.80 (1.957.06) 5.80 (1.777.30) 5.80 (1.957.07) 2.50 (1.703.46) 3.50 (1.714.79) 5.00 (1.835.94) 6.00 (1.926.45) 7.10 (2.067.17) 5.00 (1.836.10) 6.00 (1.926.49) 6.90 (2.107.31) 7.20 (2.217.66) 7.50 (2.328.00) 7.00 (2.067.16) 7.20 (2.217.65) 7.50 (2.327.95) 7.50 (2.428.27) 7.50 (2.408.09) 7.50 (2.488.32) 7.50 (2.618.50) 7.50 (2.608.50) 7.50 (2.748.62) 6.90 (2.107.46) 7.20 (2.217.87) 7.50 (2.408.36) 7.50 (2.488.63) 7.50 (2.618.86) 7.50 (2.298.23) 7.50 (2.488.63) 7.50 (2.608.84) 7.50 (2.749.01) 7.50 (2.708.92) 7.50 (2.789.04) 7.50 (2.418.53) 7.50 (2.608.84) 7.50 (2.728.98) 7.50 (2.789.07) Total power consumption (W) Rated (Min.-Max.) 620 (350 820) 960 (3501,510) 1,540 (3501,980) 1,450 (3502,140) 1,580 (3502,160) 1,470 (3502,070) 1,720 (3502,160) 1,600 (3502,080) 1,540 (3502,110) 1,410 (3702,160) 1,570 (3702,160) 1,540 (3502,240) 1,570 (3802,160) 650 (420 920) 1,010 (4201,410) 1,560 (4501,990) 2,100 (4402,320) 2,820 (4602,840) 1,660 (3902,040) 2,300 (4202,490) 2,400 (4102,570) 2,620 (4202,710) 2,760 (4403,020) 2,790 (4603,140) 2,620 (4402,810) 2,840 (4603,050) 2,740 (4903,210) 2,590 (4602,900) 2,540 (4803,060) 2,500 (5103,170) 2,500 (5103,170) 2,450 (5403,210) 2,180 (3802,490) 2,350 (4202,740) 2,360 (4502,860) 2,260 (4802,960) 2,240 (5103,020) 2,580 (4503,070) 2,360 (4803,070) 2,260 (5102,960) 2,220 (5303,130) 2,130 (5003,030) 2,080 (5603,090) 2,560 (4803,150) 2,360 (5103,230) 2,210 (5303,040) 2,130 (5603,140)

Main features

Product lineup

Functions

Specifications

Options

Capacity table

220 V, 60 Hz
Total current (A) Rated (Min.-Max.) 2.9 (1.6 3.8) 4.5 (1.6 7.0) 7.1 (1.6 9.1) 6.7 (1.6 9.8) 7.3 (1.6 9.9) 6.7 (1.6 9.5) 7.9 (1.6 9.9) 7.3 (1.6 9.6) 7.1 (1.6 9.7) 6.5 (1.7 9.9) 7.2 (1.7 9.9) 7.1 (1.610.3) 7.2 (1.7 9.9) 3.2 (2.1 4.6) 4.8 (2.0 6.7) 7.2 (2.1 9.2) 9.6 (2.010.7) 12.9 (2.113.0) 7.7 (1.8 9.5) 10.6 (1.911.4) 11.0 (1.911.8) 12.0 (1.912.4) 12.7 (2.013.9) 12.8 (2.114.4) 12.0 (2.012.9) 13.0 (2.114.0) 12.6 (2.214.7) 11.9 (2.113.3) 11.7 (2.214.0) 11.5 (2.314.6) 11.5 (2.314.6) 11.2 (2.514.7) 10.0 (1.710.9) 10.8 (1.912.0) 10.8 (2.112.6) 10.4 (2.213.0) 10.3 (2.313.3) 11.8 (2.113.5) 10.8 (2.213.5) 10.4 (2.313.0) 10.2 (2.413.7) 9.8 (2.313.3) 9.6 (2.613.6) 11.8 (2.213.8) 10.8 (2.314.2) 10.1 (2.413.4) 9.8 (2.613.8) Outdoor unit Combinations of indoor units 25 35 50 60 71 25+25 25+35 25+50 25+60 25+71 35+35 35+50 35+60 35+71 50+50 50+60 50+71 60+60 60+71 71+71 25+25+25 25+25+35 25+25+50 25+25+60 25+25+71 25+35+35 25+35+50 25+35+60 25+35+71 25+50+50 25+50+60 25+50+71 25+60+60 25+60+71 35+35+35 35+35+50 35+35+60 35+35+71 35+50+50 35+50+60 35+50+71 35+60+60 50+50+50 25+25+25+25 25+25+25+35 25+25+25+50 25+25+25+60 25+25+25+71 25+25+35+35 25+25+35+50 25+25+35+60 25+25+35+71 25+25+50+50 25+35+35+35 25+35+35+50 25+35+35+60 35+35+35+35 35+35+35+50 Capacity of each indoor unit (kW) A room 2.50 3.50 5.00 6.00 7.10 2.50 2.50 2.41 2.22 2.06 3.50 3.11 2.90 2.72 4.02 3.80 3.60 4.34 4.14 4.69 2.41 2.22 2.01 1.90 1.80 2.07 1.90 1.81 1.73 1.76 1.70 1.63 1.64 1.57 2.73 2.53 2.42 2.32 2.38 2.29 2.20 2.22 3.21 2.01 1.90 1.77 1.70 1.63 1.81 1.70 1.63 1.57 1.61 1.74 1.63 1.58 2.33 2.21 B room C room D room Total capacity (kW) Rated (Min.-Max.) 2.50 (1.79 3.60) 3.50 (1.84 4.90) 5.00 (1.99 5.82) 6.00 (2.08 6.60) 7.10 (2.19 7.38) 5.00 (1.99 6.19) 6.00 (2.08 6.60) 7.23 (2.25 7.64) 7.55 (2.38 8.25) 7.90 (2.52 8.53) 7.00 (2.18 7.31) 7.55 (2.38 8.02) 7.87 (2.51 8.52) 8.23 (2.65 8.54) 8.03 (2.58 8.49) 8.35 (2.71 8.83) 8.71 (2.85 9.03) 8.68 (2.84 9.34) 9.03 (2.98 9.36) 9.38 (3.13 9.57) 7.23 (2.25 7.64) 7.55 (2.38 8.25) 8.03 (2.58 8.66) 8.35 (2.71 9.17) 8.71 (2.85 9.37) 7.87 (2.51 8.63) 8.35 (2.71 8.85) 8.68 (2.84 9.36) 9.03 (2.98 9.38) 8.84 (2.90 9.34) 9.16 (3.04 9.67) 9.51 (3.18 9.69) 9.48 (3.1710.01) 9.80 (3.3110.22) 8.19 (2.64 8.82) 8.68 (2.84 9.03) 9.00 (2.97 9.37) 9.35 (3.12 9.49) 9.16 (3.04 9.34) 9.48 (3.17 9.68) 9.80 (3.31 9.94) 9.80 (3.3010.26) 9.64 (3.23 9.89) 8.04 (2.58 9.03) 8.35 (2.71 9.19) 8.84 (2.90 9.68) 9.16 (3.0410.02) 9.51 (3.1810.36) 8.68 (2.84 9.38) 9.16 (3.04 9.69) 9.48 (3.1710.34) 9.80 (3.3110.50) 9.64 (3.2310.45) 9.00 (2.97 9.41) 9.48 (3.17 9.70) 9.80 (3.3010.49) 9.32 (3.10 9.40) 9.80 (3.3010.49) Total power consumption (W) Rated (Min.-Max.) 710 (4001,290) 1,060 (4301,620) 1,580 (4101,940) 1,810 (4102,160) 2,420 (4402,640) 1,290 (3801,910) 1,820 (4102,110) 2,390 (4502,610) 2,410 (4802,880) 2,590 (5203,010) 2,360 (4402,580) 2,550 (4802,840) 2,580 (5203,000) 2,820 (5203,010) 2,700 (5203,000) 2,730 (5503,050) 2,980 (5503,180) 2,770 (5503,220) 2,960 (5803,230) 3,100 (6203,230) 2,190 (4502,470) 2,410 (4802,820) 2,550 (5202,920) 2,580 (5203,090) 2,710 (5503,230) 2,590 (5202,880) 2,730 (5503,050) 2,770 (5503,230) 2,960 (5803,230) 2,890 (5503,220) 2,860 (5903,270) 3,000 (6203,280) 2,830 (5903,320) 3,180 (6203,470) 2,760 (5203,010) 2,990 (5503,180) 2,960 (5803,230) 3,160 (6203,230) 3,090 (5803,220) 3,070 (6203,270) 3,280 (6203,490) 3,110 (6203,540) 3,200 (6203,480) 2,400 (5203,030) 2,580 (5203,090) 2,740 (5603,270) 2,770 (5903,320) 2,970 (5903,330) 2,770 (5503,230) 2,930 (5903,280) 2,970 (5903,320) 3,180 (6203,470) 3,110 (6203,840) 2,960 (5803,230) 3,140 (6203,280) 3,180 (6203,470) 3,230 (6203,230) 3,420 (6203,860) Total current (A) Rated (Min.-Max.) 3.3 (1.9 6.0) 4.9 (2.0 7.5) 7.3 (1.9 9.0) 8.4 (1.910.0) 11.2 (2.012.2) 6.0 (1.8 8.9) 8.4 (1.9 9.8) 11.1 (2.112.1) 11.2 (2.213.4) 12.0 (2.414.0) 10.9 (2.012.0) 11.8 (2.213.2) 12.0 (2.413.9) 13.1 (2.414.0) 12.5 (2.413.9) 12.7 (2.614.1) 13.8 (2.614.7) 12.8 (2.614.9) 13.7 (2.715.0) 14.4 (2.915.0) 10.2 (2.111.5) 11.2 (2.213.1) 11.8 (2.413.5) 12.0 (2.414.3) 12.6 (2.615.0) 12.0 (2.413.4) 12.7 (2.614.1) 12.8 (2.615.0) 13.7 (2.715.0) 13.4 (2.614.9) 13.3 (2.715.2) 13.9 (2.915.2) 13.1 (2.715.4) 14.7 (2.916.1) 12.8 (2.414.0) 13.9 (2.614.7) 13.7 (2.715.0) 14.7 (2.915.0) 14.3 (2.714.9) 14.2 (2.915.2) 15.2 (2.916.2) 14.4 (2.916.4) 14.8 (2.916.1) 11.1 (2.414.1) 12.0 (2.414.3) 12.7 (2.615.2) 12.8 (2.715.4) 13.8 (2.715.4) 12.8 (2.615.0) 13.6 (2.715.2) 13.8 (2.715.4) 14.7 (2.916.1) 14.4 (2.917.8) 13.7 (2.715.0) 14.6 (2.915.2) 14.7 (2.916.1) 15.0 (2.915.0) 15.9 (2.917.9)

3MKS58KVM

2.50 3.05 3.71 2.73 3.41 2.90 1.86 1.71 1.45 2.14

1.86 2.38 2.90 2.14

3MKS75KVM

2.50 3.50 4.60 5.08 5.55 3.50 4.24 4.74 5.02 3.75 4.09 4.40 3.75 4.06 2.30 2.12 1.88 1.70 1.55 2.76 2.39 2.19 2.00 3.00 2.78 2.50 2.19 2.02 2.78

4MKS100KVM

2.30 2.96 3.74 4.10 4.40 2.76 3.41 3.75 4.07 3.00 3.33 2.50 3.12 3.46 2.78

Notes: 1. Cooling operation data is based on the following conditions: indoor temp.26.7CDB, 19.4CWB; outdoor temp.35CDB. 2. Total capacity of connected indoor units is: up to 10.0kW to the 3MKS58KVM; up to 13.5 kW to the 3MKS75KVM.

2.50 3.50 4.82 5.33 5.84 3.50 4.44 4.97 5.51 4.02 4.55 5.11 4.34 4.89 4.69 2.41 2.22 2.01 1.90 1.80 2.90 2.66 2.53 2.41 3.54 3.39 3.26 3.92 3.77 2.73 2.53 2.42 2.32 3.39 3.27 3.14 3.79 3.21 2.01 1.90 1.77 1.70 1.63 1.81 1.70 1.63 1.57 1.61 2.42 2.29 2.21 2.33 2.21

2.41 3.11 4.01 4.55 5.11 2.90 3.79 4.34 4.89 3.54 4.07 4.62 3.92 4.46 2.73 3.62 4.16 4.71 3.39 3.92 4.46 3.79 3.21 2.01 1.90 1.77 1.70 1.63 2.53 2.37 2.29 2.20 3.21 2.42 2.29 2.21 2.33 2.21

2.01 2.65 3.53 4.06 4.62 2.53 3.39 3.93 4.46 3.21 2.42 3.27 3.80 2.33 3.17

Notes: 1. Cooling operation data is based on the following conditions: indoor temp.26.7CDB, 19.4CWB; outdoor temp.35CDB. 2. Total capacity of connected indoor units is up to 15.6kW to the 4MKS100KVM.

21

22

Capacity table

Main features

Product lineup

Functions

Specifications

Options

Capacity table

220 V, 60 Hz
Outdoor unit Combinations of indoor units 25 35 50 60 71 25+25 25+35 25+50 25+60 25+71 35+35 35+50 35+60 35+71 50+50 50+60 50+71 60+60 60+71 71+71 25+25+25 25+25+35 25+25+50 25+25+60 25+25+71 25+35+35 25+35+50 25+35+60 25+35+71 25+50+50 25+50+60 25+50+71 25+60+60 25+60+71 35+35+35 35+35+50 35+35+60 35+35+71 35+50+50 35+50+60 35+50+71 35+60+60 50+50+50 25+25+25+25 25+25+25+35 25+25+25+50 25+25+25+60 25+25+25+71 25+25+35+35 25+25+35+50 25+25+35+60 25+25+35+71 25+25+50+50 25+35+35+35 25+35+35+50 25+35+35+60 35+35+35+35 35+35+35+50 25+25+25+25+25 25+25+25+25+35 25+25+25+25+50 25+25+25+35+35 25+25+35+35+35 Capacity of each indoor unit (kW) A room 2.50 3.50 5.00 6.00 7.10 2.50 2.50 2.43 2.29 2.17 3.50 3.21 3.05 2.91 4.27 4.10 3.95 4.76 4.61 5.30 2.43 2.29 2.13 2.05 1.98 2.18 2.05 1.98 1.92 1.96 1.90 1.85 1.85 1.76 2.92 2.77 2.70 2.62 2.65 2.59 2.47 2.48 3.66 2.13 2.05 1.95 1.90 1.85 1.98 1.90 1.85 1.76 1.83 1.91 1.85 1.77 2.63 2.48 1.95 1.90 1.83 1.85 1.78 B room C room D room E room Total capacity (kW) Rated (Min.-Max.) 2.50 (1.98 3.54) 3.50 (1.98 3.70) 5.00 (2.34 5.86) 6.00 (2.37 6.99) 7.10 (2.39 7.42) 5.00 (2.69 6.29) 6.00 (2.69 7.39) 7.29 (2.91 9.57) 7.79 (2.94 9.73) 8.33 (2.9610.20) 7.00 (2.70 7.74) 7.79 (2.91 9.59) 8.28 (2.9410.09) 8.82 (2.9610.22) 8.53 (3.0811.20) 9.02 (3.1011.34) 9.56 (3.1211.44) 9.51 (3.1211.47) 10.06 (3.1311.57) 10.60 (3.2611.66) 7.29 (2.94 9.74) 7.79 (2.94 9.76) 8.53 (3.1011.35) 9.02 (3.1211.48) 9.56 (3.1411.58) 8.28 (2.9410.12) 9.02 (3.1111.36) 9.51 (3.1211.50) 10.06 (3.1411.59) 9.76 (3.2212.19) 10.25 (3.2312.28) 10.80 (3.2412.34) 10.75 (3.3112.36) 11.00 (3.3212.41) 8.77 (2.9510.14) 9.51 (3.1111.38) 10.01 (3.1311.51) 10.55 (3.2711.60) 10.25 (3.2212.20) 10.75 (3.3712.29) 11.00 (3.3812.34) 11.00 (3.3812.36) 10.99 (3.4312.66) 8.53 (3.1211.49) 9.02 (3.1211.50) 9.76 (3.2312.28) 10.25 (3.2412.36) 10.80 (3.2512.41) 9.51 (3.1311.52) 10.25 (3.2312.29) 10.75 (3.2412.37) 11.00 (3.2512.42) 10.99 (3.2912.69) 10.01 (3.1311.53) 10.75 (3.2412.30) 11.00 (3.2512.37) 10.50 (3.1311.54) 11.00 (3.2412.31) 9.76 (3.2412.36) 10.25 (3.2512.37) 11.00 (3.3012.80) 10.75 (3.2512.38) 11.00 (3.2512.39) Total power consumption (W) Rated (Min.-Max.) 640 (500930) 900 (500990) 1,260 (5301,700) 1,760 (5302,520) 2,580 (5302,910) 1,240 (5501,640) 1,720 (5502,420) 2,040 (5503,440) 2,270 (5503,440) 2,580 (5503,960) 2,470 (5502,800) 2,330 (5503,440) 2,640 (5503,960) 3,040 (5503,960) 2,330 (5504,010) 2,570 (5504,010) 2,960 (5504,010) 2,890 (5504,010) 3,230 (5504,010) 3,550 (5504,000) 1,990 (5503,440) 2,270 (5503,440) 2,270 (5504,010) 2,510 (5504,010) 2,890 (5504,010) 2,580 (5503,960) 2,570 (5504,010) 2,890 (5504,010) 3,230 (5504,000) 2,690 (5503,990) 3,010 (5503,980) 3,360 (5503,980) 3,290 (5503,980) 3,460 (5503,980) 3,040 (5503,960) 2,890 (5504,010) 3,230 (5504,010) 3,550 (5504,000) 3,010 (5503,990) 3,360 (5503,980) 3,460 (5503,980) 3,460 (5503,980) 3,270 (5503,960) 2,260 (5504,010) 2,510 (5504,010) 2,680 (5503,980) 2,940 (5503,980) 3,280 (5503,980) 2,830 (5504,010) 2,940 (5503,980) 3,280 (5503,980) 3,460 (5503,980) 3,270 (5503,960) 3,230 (5504,010) 3,360 (5503,980) 3,460 (5503,980) 3,550 (5504,010) 3,460 (5503,980) 2,620 (5503,980) 2,940 (5503,980) 3,270 (5504,030) 3,280 (5503,980) 3,460 (5503,980) Total current (A) Rated (Min.-Max.) 3.0 (2.4 4.4) 4.2 (2.4 4.7) 5.9 (2.5 8.0) 8.2 (2.511.9) 12.1 (2.513.7) 5.8 (2.6 7.7) 8.1 (2.611.4) 9.6 (2.616.2) 10.6 (2.616.2) 12.1 (2.618.6) 11.6 (2.613.2) 10.9 (2.616.2) 12.4 (2.618.6) 14.2 (2.618.6) 10.9 (2.618.8) 12.0 (2.618.8) 13.9 (2.618.8) 13.5 (2.618.8) 15.1 (2.618.8) 16.6 (2.618.8) 9.3 (2.616.2) 10.6 (2.616.2) 10.6 (2.618.8) 11.8 (2.618.8) 13.5 (2.618.8) 12.1 (2.618.6) 12.0 (2.618.8) 13.5 (2.618.8) 15.1 (2.618.8) 12.6 (2.618.7) 14.1 (2.618.7) 15.7 (2.618.7) 15.4 (2.618.7) 16.2 (2.618.7) 14.2 (2.618.6) 13.5 (2.618.8) 15.1 (2.618.8) 16.6 (2.618.8) 14.1 (2.618.7) 15.7 (2.618.7) 16.2 (2.618.7) 16.2 (2.618.7) 15.3 (2.618.6) 10.6 (2.618.8) 11.8 (2.618.8) 12.6 (2.618.7) 13.8 (2.618.7) 15.4 (2.618.7) 13.3 (2.618.8) 13.8 (2.618.7) 15.4 (2.618.7) 16.2 (2.618.7) 15.3 (2.618.6) 15.1 (2.618.8) 15.7 (2.618.7) 16.2 (2.618.7) 16.6 (2.618.8) 16.2 (2.618.7) 12.3 (2.618.7) 13.8 (2.618.7) 15.3 (2.618.9) 15.4 (2.618.7) 16.2 (2.618.7)

5MKS110LVM

2.50 3.50 4.86 5.50 6.16 3.50 4.58 5.23 5.91 4.27 4.92 5.61 4.76 5.45 5.30 2.43 2.29 2.13 2.05 1.98 3.05 2.87 2.77 2.69 3.90 3.80 3.70 4.45 4.23 2.92 2.77 2.70 2.62 3.80 3.71 3.53 4.26 3.66 2.13 2.05 1.95 1.90 1.85 1.98 1.90 1.85 1.76 1.83 2.70 2.59 2.48 2.63 2.48 1.95 1.90 1.83 1.85 1.78

2.43 3.21 4.27 4.92 5.60 3.05 4.10 4.76 5.45 3.90 4.55 5.25 4.45 5.01 2.92 3.97 4.61 5.31 3.80 4.45 5.00 4.26 3.66 2.13 2.05 1.95 1.90 1.85 2.77 2.66 2.59 2.47 3.66 2.70 2.59 2.48 2.63 2.48 1.95 1.90 1.83 1.85 2.48

2.13 2.87 3.91 4.55 5.25 2.77 3.79 4.46 5.01 3.66 2.70 3.72 4.27 2.63 3.56 1.95 1.90 1.83 2.60 2.48

1.95 2.65 3.68 2.60 2.48

Notes: 1. Cooling operation data is based on the following conditions: indoor temp.27CDB, 19CWB; outdoor temp.35CDB. corresponding refrigerant piping length: 5m; level difference: 0m. 2. Total capacity of connected indoor units is up to 15.6kW to the 5MKS110LVM. 3. The above is the value for connecting with the following indoor units: 2.5/3.5/5.0/6.0/7.1kW class, wall-mounted K series.

23

24

Memo

25

26

You might also like