You are on page 1of 196

2nd edition

600 mm Connectivity Products


Complete Guide to Fiber and Copper Connectivity

Table of Contents
Introduction ................................................................................................................................1 Fiber Distributing Frames Next Generation Frame 600 mm Products Introduction ....................................................................................................................................2 Fiber Main Distributing Frame (FMDF) Frame Section......................................................................3 Front Facing Fiber Main Distributing Frame (F3MDF) Frame Section ..............................................4 Fiber Slim Rack Frame Section ........................................................................................................5 Fiber Termination Blocks (FTB) Unterminated ..................................................................................6 Fiber Termination Blocks Cable Clamping Kit ................................................................................7 Fiber Termination Blocks (FTB) Preterminated ..............................................................................8-9 Fiber Combination Blocks (FCB) ..............................................................................................10-11 Splice Trays for Fiber Combination Block ......................................................................................11 Sliding Adapter Packs ..................................................................................................................12 Value-Added Module System Chassis ..........................................................................................13 Fiber Optic Terminal Jumper Storage Bay ......................................................................................14 Equipment Bay..............................................................................................................................15 Accessories End Guard ..............................................................................................................................16 Cable Clamp Kits ....................................................................................................................16 Rack Installation Kits................................................................................................................16 AC Outlets Kits........................................................................................................................16 OMX Optical Distribution Frames Introduction ............................................................................................................................17-18 Frame Section ..............................................................................................................................19 Termination Module with Adapters Only ......................................................................................20 Termination Module with Pigtails..................................................................................................21 Termination Module with IFC........................................................................................................22 Value-Added Module System Chassis ..........................................................................................23 Splice Module ..............................................................................................................................24 Splice Tray ....................................................................................................................................24 Accessories Jumper Storage Module ..........................................................................................................25 Interbay Management Panel....................................................................................................25 End Guard ..............................................................................................................................25 Outside Plant Cable Clamp......................................................................................................26 Rack Installation Kits................................................................................................................26 Splice Bay......................................................................................................................................27 Fiber Panels FL1000 Fiber Termination Products Two-Door Wall Mount Boxes ..................................................................................................28-29 Two-Door Wall Mount Boxes with MTRJ Connectors....................................................................30 One-Door Wall Mount Boxes ..................................................................................................31-32 6pak Adapter Packs ......................................................................................................................33 FL2000 System Introduction ..................................................................................................................................34 Preconfigured Termination Panels with Multifiber Cable..........................................................35-36 Preconfigured Termination Panels with Pigtails ............................................................................37 Preconfigured Termination/Splice Panels with Pigtails....................................................................38 Termination Panels with MTRJ Connectors....................................................................................39 Empty Termination Panels ............................................................................................................40 Empty Splice Panels ......................................................................................................................41 Empty Termination/Splice Panels ..................................................................................................42
www.adc.com +32-2-712-65-00 +32-2-712-65-42

10/03

100571

600 mm Products

Table of Contents
FL2000 Slack Storage Solutions Fiber Storage Disk....................................................................................................................43 Fiber Storage Tray ....................................................................................................................43 Storage Deck Panel..................................................................................................................44 Horizontal Interbay Management Panel ..................................................................................44 FL2000 6pak Adapter Packs Adapters Only..........................................................................................................................45 Adapters and Pigtail ................................................................................................................46 Accessories Locks ......................................................................................................................................47 End Guards..............................................................................................................................47 Lower Cable Trough ................................................................................................................47 Bonding/Grounding Kit............................................................................................................47 Cable Clamp Kits ....................................................................................................................47 Blank Vertical Cable Guides (VCGs) ........................................................................................47 Interbay Management Panel for 19- or 23-Inch Racks ............................................................48 Interbay Management Panel and Inner IMP for 600 mm and 800 mm cabinets and racks ....48 FL2000 Mounting Options 19" (48.26 cm) Rack Mounting Standard Mount (as shipped) ..............................................................................................49 Flush Mount........................................................................................................................49 19"Maximum Mounting ........................................................................................................50 19" ETSI Mounting..................................................................................................................51 600 mm Mounting..................................................................................................................51 FL2000 VAM System Chassis ........................................................................................................52 Value-Added Module System Chassis used in Non-ADC Optical Distribution Frame 4-Inch Chassis 6 Single Plug-In Modules ........................................................................................53 3.5-Inch Chassis 4 Single Plug-In Modules ......................................................................................53 1.75-Inch Chassis 2 Single Plug-In Modules ....................................................................................53 Value-Added Module System Splitter Modules ................................................................................................................................55 Wavelength Division Multiplexer Modules..........................................................................................56 Monitor Modules ..............................................................................................................................57 Configuration Illustrations ..................................................................................................................58 Bulkhead Plates and Blanks ................................................................................................................59 Terminators ........................................................................................................................................59 Specifications ................................................................................................................................60-62 Fiber Management Tray Introduction ......................................................................................................................................63 1 Rack Unit Termination Only ..........................................................................................................................64 Termination and Splice..................................................................................................................65 Termination and Storage ..............................................................................................................66 Bulk Storage Drawer ....................................................................................................................67 Discrete Storage Drawer ..............................................................................................................67 Splicing Only ................................................................................................................................68 Termination and Splice Fixed Bulkhead ........................................................................................69 Termination and Storage Fixed Bulkhead ......................................................................................70 Accessories ..................................................................................................................................71 Sliding Adapter Packs Wall Mount Kit

10/03

100571

600 mm Products

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

Table of Contents
Cable Clamp Kits Vertical Cable Guides Specifications ................................................................................................................................72 2 Rack Unit Termination with Adapters Only ..................................................................................................73 Termination with IFC or Multifiber Cable ......................................................................................74 Termination and Splice..................................................................................................................75 Accessories ..................................................................................................................................76 Sliding Adapter Packs Cable Clamp Kits Vertical Cable Guides Micro Value-Added Module System Chassis ....................................................................................................................................77 Monitor Modules ....................................................................................................................78 Fiber Optic Cable Assemblies Patch Cords Singlemode ..................................................................................................................................79 Multimode ....................................................................................................................................79 Multifiber Patch Cords Singlemode ..................................................................................................................................80 Multimode ....................................................................................................................................80 TracerLight Connector Identification System Simplex ........................................................................................................................................81 Duplex ..........................................................................................................................................82 Fiber Optic Cable Assemblies (Intrafacility Cable) ..........................................................................83-84 Specifications ................................................................................................................................85-86 Fiber Cable Raceway Systems Standard ......................................................................................................................................87-96 Plenum........................................................................................................................................97-102 Power Distribution Products Select Series Fuse Platform ............................................................................................................103 Uninterrupted GMT Series................................................................................................................104 Traditional GMT Series ....................................................................................................................105 Advantage Series Platform ............................................................................................................106 Accessories ................................................................................................................................107 Carling Breakers TPC Fuses/Fuse Holder Compression Lugs Circuit Breaker Fingerguards Circuit Breaker/TPC Fuse Designation Cards TPC Fuse Hider Adapter PowerWorx Accessories GMT Fuse Puller..........................................................................................................................108 Designation Card Holder and Cards............................................................................................108 GMT Designation Pin Holder ......................................................................................................108 Fuses ........................................................................................................................................109 GMT Fuses/Fuse Designation Pins Alarm Indicator ..................................................................110 Compression Lugs ......................................................................................................................110 Cable Management Bars ............................................................................................................110

10/03

100571

600 mm Products

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

Table of Contents
DSX Modular Rear Cross-Connect RZX-3 Modules ........................................................................................................................111-112 RZX-3 Chassis ..................................................................................................................................113 Preterminated Option ......................................................................................................................113 Skeleton Bay ....................................................................................................................................114 RZX-3 End Guard ............................................................................................................................114 Digital Distribution Frame System Modules ........................................................................................................................................116 Standard Configuration....................................................................................................................117 Unloaded Chassis Skeleton Bay Wall Mount Box ..............................................................................................................................118 DSX-3 Patch Cords ........................................................................................................................119 Patch Cords with RG59 Type Cable Factory-Terminated Rear Cross-Connect Jumpers Factory-Terminated Patch Cords DSX-3 Accessories Coaxial Connectors ..........................................................................................................................120 Tracer Pins ........................................................................................................................................120 Tool Kit ............................................................................................................................................121 Coaxial Tools ....................................................................................................................................121 2 Mbps DSX Front Cross-Connect Solutions Introduction ..............................................................................................................................122-123 Selection Guide ................................................................................................................................124 Skeleton Bay for FlexDSX , PxPlus and DSX 64 Panels ............................................................125 FlexDSX Platform ......................................................................................................................126 Four-Port (Dual Monitor) Jack Access ....................................................................................127 Modules and Cards ..............................................................................................................128 All-Front-Access Panels ........................................................................................................129 PxPlus Panels ............................................................................................................................130 Empty Chassis Jack Card DSX 64-Termination Three-Port Fixed Panel ............................................................................131 Bay Hardware and Accessories End Guard ..................................................................................................................................132 Frame Doors ..............................................................................................................................132 End Guard for Use with Door Enclosure Kit................................................................................132 Filler Panel Kits............................................................................................................................132 Rack Installation Kit ....................................................................................................................133 AC Outlet Kit ..............................................................................................................................133 Cross Aisle Panels ......................................................................................................................133 Alarm Panels ..............................................................................................................................133 2 Mbps DSX Super High Density Solutions DSX600 Bay ............................................................................................................................134-137 FlexDSX Super High Density Bay..............................................................................................138-140 Accessories Bantam Patch Cords ..................................................................................................................141 Tools and Tool Kits ......................................................................................................................142 Cross-Connect Wire....................................................................................................................142

10/03

100571

600 mm Products

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

Table of Contents
Impedance Matching Panel ............................................................................................143-145 BroadWire ETSI Series Applications ....................................................................................................................................147 Configurations ................................................................................................................................148 Specifications BroadWire 240 ETSI Series ........................................................................................................149 BroadWire 120 ETSI Series ........................................................................................................150 T1.413 Compliant ADSL/POTS Splitter Card ..............................................................................151 ETSI ADSL/POTS Splitter Card......................................................................................................151 4B3T ADSL/ISDN Splitter Card ....................................................................................................152 Combination ADSL/ISDN/POTS Splitter Card ..............................................................................152 2B1Q ADSL/ISDN Splitter Card....................................................................................................153 Ordering Information ......................................................................................................................153 BroadWire 24 High Density ADSL Splitters Applications ....................................................................................................................................155 Specifications Chassis for Worldwide Deployment ............................................................................................156 Chassis for North American Deployment ....................................................................................157 T1.413 Compliant ADSL/POTS Splitter Card ..............................................................................158 4B3T ADSL/ISDN Splitter Card ....................................................................................................158 2B1Q ADSL/ISDN Splitter Card....................................................................................................159 Complex Impedance ADSL/POTS Splitter Card............................................................................159 Ordering Information ......................................................................................................................160 Ethernet/Data Connectivity Glide Cable Manager................................................................................................................161-162 T1/E1 Demarcation Modular Patch Panels........................................................................................163 6000CHC Patch Panels Category 6 ............................................................................................164 5000E Patch Panels Category 5e ................................................................................................165 RJ45 Coupler Panel Category 5 ..................................................................................................166 Fast Ethernet Patch Panels................................................................................................................167 6000 Multimedia Patch Panels ........................................................................................................168 6000 Modular Jacks and Icons....................................................................................................169 6000 Media Adapters ................................................................................................................170 6000 High Performance Patch Cords ..............................................................................................171 25-Pair Cable Assemblies ................................................................................................................172 6000 Faceplates ..............................................................................................................................173 ADC IEEE 1394a FireWire Patch Panel ............................................................................................174 Media Converters OptEnet Media Converter Platform ........................................................................................175-180 Work Area Media Converter ............................................................................................................181

10/03

100571

600 mm Products

Customer Information and Assistance ..............................................................................182 Index ......................................................................................................................................183

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

600 mm Products
Introduction ADC The Connectivity Foundation for Networks in Transition
The reality of todays marketplace dictates that service provider networks change to remain competitive. New modulation techniques. Faster metro optical fiber rings. Voice, high-speed data and multimedia services deployed closer than ever to the edge of the network. These changes are largely upgrades and reconfigurations designed to improve reliability, availability, accuracy and breadth of services. Establishing a solid network foundation rooted in connectivity has already proven successful as networks transitioned from analog to digital and from copper to fiber, and as service providers joined networks together through collocation and consolidation. As service providers approach the convergence of voice, data and video with IP-based services, a foundation of connectivity remains just as essential. Moving to new and more complex network models with a connectivity foundation in place delivers multiple, proven benefits: Minimize operational costs. The capital allocated to purchase new electronics, software and connectivity pales in comparison to the multi-year, ongoing cost of labor to manage and maintain the network. With a connectivity foundation, labor costs for everything from initial installation, to provisioning, to upgrades and reconfigurations, to maintenance is reduced. Minimizing operational costs contributes to the bottom line just as strongly as new revenue sources. Increase network reliability. More and more, 99.99% availability pertains to more than just voice services. With ILECs, MSOs, wireless service providers and others vying for the same customers, quality of service measures and service level agreements will soon pertain to voice, data and video services. Connectivity delivers reliability by providing termination, test access, and cable management strategies that ensure maximum service availability. Maximize revenue. The competition is positioning to earn new revenues from broadband services and take away annuity business from others in the marketplace. A solid connectivity foundation speeds service provisioning while, at the same time, lowers the cost of provisioning. With faster turn-up of servicesand associated acceleration of revenueservice providers wield an attractive weapon in competing for customers. ADC is the market leader in the deployment of connectivity solutions for copper, fiber and wireless networks around the world. With hundreds of millions of ports in service worldwide, over 600 patents, and connectivity solutions that touch the majority of worldwide voice, video, and data communications traffic, ADC has the products, services, and experience to make the inevitable work of network transitions cost effective and profitable for service providers.

10/03

100571

600 mm Products

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

Next Generation Frame 600 mm Products


Introduction
Frames
ADCs Next Generation Frame product line has fiber frames designed to fit a variety of termination, splice, and storage applications. Each frame option is designed with an emphasis on superior cable management and ease of use, including features such as ample trough space for cable and jumpers, easy access to connectors, and storage for jumpers. The frame sections are shipped from the factory fully equipped with all cable management hardware including a built-in jumper storage panel.

Fiber Termination Blocks (FTB)

600 mm Products

Fiber Termination Blocks (FTBs) are available with SC, FC, ST and E-2000 adapters in block configurations of 48, 72 or 96 positions. Also, 144 position FTBs are available using LX.5 and LC adapters. FTBs utilize sliding adapter packs to gain easy access to both the front and rear connectors. There is also a block configuration available to accommodate Mini Value-Added Modules (Mini VAMs) for applications requiring splitters or WDMs. FTBs can be ordered with or without IFC or outside plant cable.

Fiber Combination Blocks Blocks (FCB)


Fiber Combination Blocks (FCBs) provide termination and on-frame splicing capabilities, all in one block. The block occupies two mounting positions on the frame section. They are available with SC, FC, ST and E-2000 adapters in block configurations of 48, 72 or 96 positions. Also, 144 position FCBs are available using LX.5 or LC adapters.

Features and Benefits


Ample Trough Space Reduces jumper pile-up and congestion - Reduces maintenance time due to easy removal and tracing of jumpers - Minimizes risk of microbends or damage to fiber Built-in Jumper Storage Panel Minimizes number of required jumper lengths Maintains fiber bend radius Simplifies frame installation - Saves money by reducing the number of different jumper lengths that have to be kept in inventory - Minimizes risk of microbends or damage to fiber Sliding Adapter Packs Promotes high density Provides easy access to connectors - Saves valuable floor space - Reduces time required for operations and maintenance Intelligent Cable Routing System No fiber cross-over points Multiple vertical troughways - Reduces maintenance time due to easier removal and tracing of jumpers and minimizes fiber weaving

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

Next Generation Frame 600 mm Products


Fiber Main Distributing Frame (FMDF)
The FMDF is the cornerstone of the NGF product line. This innovative frame has six rear horizontal troughs. This abundant trough space minimizes fiber pile up and congestion leading to easier jumper traceability and removal. The frame has twelve Fiber Termination Block (FTB) mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below. The frame is 600 mm wide x 600 mm deep. The built-in jumper storage panel will store up to 5 meters of jumper slack.

Left Vertical

Right Vertical

600 mm Products

Jumper Storage Panel

Horizontal Trough (6)

FTB Mounting Position (12)

600 mm

600 mm

100571

Front ISO View

Front View

Side View

Ordering Information
Description 600 mm FMDF frame section Dimensions 2.2 m x 600 mm x 600 mm Catalog Number NGF-ETSIMDF6060

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

Next Generation Frame 600 mm Products


Front Facing Fiber Main Distributing Frame (F3MDF)
The F3MDF is designed for single-sided access applications and may be mounted up against a wall or backto-back to save floor space. Unlike the FMDF, the more compact F3MDF is equipped with a single 230 mm horizontal trough. The F3MDF has twelve FTB mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below. The frame is 600 mm wide x 480 mm deep. The built-in jumper storage panel will store up to 5 meters of jumper slack.
Left Vertical Right Vertical

600 mm Products

Jumper Storage Panel

FTB Mounting 2.2 m Position (12)

Horizontal Trough (6)

600 mm

480 mm

100571

Front ISO View

Front View

Side View

Ordering Information
Description 600 mm F3MDF frame section Dimensions 2.2 m x 600 mm x 480 mm Catalog Number NGF-ETSIF3MDF6048

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

Next Generation Frame 600 mm Products


Fiber Slim Rack
The Fiber Slim Rack is designed for lower density applications than the FMDF or F3MDF. It has six FTB mounting positions and is designed for single-sided access applications. The Slim Rack is intended for use in a single frame application and should not be used in a multiframe lineup. The built-in jumper storage panel will store up to 5 meters of jumper slack. When ordering FTBs for the Slim Rack, remember that only left oriented blocks are used on this frame.

600 mm Products

FTB Mounting Position Jumper Storage Panel

2.14 m

100571

480 mm

480 mm

Front ISO View

Front View

Side View

Ordering Information
Description NGF Fiber Slim Rack frame section Dimensions 2.14 m x 480 mm x 480 mm Catalog Number NGF-SLM7A100

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

Next Generation Frame 600 mm Products


Fiber Termination Blocks (FTB) Unterminated
FTBs without fiber can be ordered fully loaded with adapters or empty (no adapters), in which case the adapter packs for the block must be ordered separately (see page 12). Before ordering, determine the block orientation and cable exit direction. Unterminated FTBs may be ordered with a left orientation (mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame). The cable exit direction will be either upward (cables terminated to the rear side of the block exit up toward the top of the frame) or downward (cables terminated to the rear side of the block exit down toward the bottom of the frame). All blocks with adapters only are configured to terminate single or dual jumpers on the rear of the block. If a multifiber breakout style cable (i.e., OSP/IFC) is to be terminated to the rear of the block, a separate clamping kit is required (see page 7).

600 mm Products

Catalog Number NGF-TB Block Style Adapter Type Singlemode

1 1
2 3 4

SC FC/ST E-2000 LX.5/LC

Block Orientation

3 L

Left Right

7 8 L 2 3 Q 4 V N X K

Cable Exit Direction Block Configuration

100571

2 A 48

4 U
D

Upward Downward

B 72 C 96 M 144 (LX.5 or LC only)*

* 144 blocks using style 1, 2, or 3 cannot be used in 26" wide NGF frames

10/03

Adapter Type SC ultra polish (62.5/125) SC ultra polish, Multimode zirconia sleeve SC 8 angled polish OR 9 SC FC ultra polish A FC FC ultra polish, 5 ST zirconia sleeve Y LX.5 FC 8 angled polish (144 only) ST ultra polish P LC E-2000 angled polish (144 only) LX.5 ultra polish (144 only) LX.5 angled polish (144 only) LC ultra polish (144 only)

Definition of Variables Block Style General adapter type required in the FTB Block Configuration Maximum number of terminations that the FTB will accommodate when fully loaded Block Orientation Vertical column of the frame the FTB is to be mounted on Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB Adapter Type Specific adapter type required in the FTB

1 2 3 4

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

Next Generation Frame 600 mm Products


Fiber Termination Blocks Cable Clamping Kit
Clamping kit includes: Cable clamp, protective cover and fanout bracket. It is required when terminating a multifiber breakout style cable to the rear of the block.
Protective Cover

600 mm Products

Fanout Bracket

72 position block loaded with jumpers

72 position block loaded with multifiber breakout cable

72 position block with clamping kit

Ordering Information
Description Block style originally purchased All 48- and 72-position blocks 96- or 144-position Left Up Blocks 96- or 144-position Right Up Blocks 96- or 144-position Left Down Blocks 96- or 144-position Right Down Blocks Catalog Number NGF-ACCOSPKIT02 NGF-ACCRCMSLU NGF-ACCRCMSRU NGF-ACCRCMSLD NGF-ACCRCMSRD Rear Cable Management Tray for 144 Block Conversion Kit

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

Next Generation Frame 600 mm Products


Fiber Termination Blocks (FTB) Preterminated
Preterminated FTBs are available with either indoor or outdoor rated cable in ribbon or stranded configurations. All blocks are 100% factory tested to guarantee continuity and reliable connections. Preterminated FTBs make installation quick and easy, reducing labor costs. Before ordering, determine the block orientation and cable exit direction. Preterminated FTBs may be ordered with a left orientation (mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame). The cable exit direction will be either upward (cables terminated to the rear side of the block exit up toward the top of the frame) or downward (cables terminated to the rear side of the block exit down toward the bottom of the frame).

600 mm Products

Preterminated Fiber Termination Blocks arrive from the factory with either IFC or OSP Cables

Fiber cable easily uncoils during installation

Fiber Termination Block ships inside the drum

Fiber Termination Block loaded with multifiber breakout cable

Ordering information follows on next page. Definition of Variables

100571

1 2 3 4

Block Style General adapter type required in the FTB Block Configuration Maximum number of terminations that the FTB will accommodate when fully loaded Block Orientation Vertical column of the frame the FTB is to be mounted on Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB Adapter/Connector #1 Specific adapter/connector type required in the FTB. Refers to the adapter/ connector type at the FTB Connector #2 Specific connector type required at the cable end opposite the FTB Cable Type Type of cable to be terminated to the FTB Cable Length Required length of the cable terminated to the FTB

10/03

6 7 8

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

Next Generation Frame 600 mm Products


Preterminated FTBs
Catalog Number NGF-TB Cable Length Block Style

8 XXX Length in
meters

1 2 3 4

SC FC/ST E-2000 LX.5/LC

Adapter Type Singlemode

IFC Type Singlemode

Glass Type House Cable* House Cable* House Cable* Corning Corning Corning Corning Corning Corning Corning Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo

600 mm Products

7 8 L 2 3 Q 4 V N X K

Block Configuration

2 A 48

B 72 C 96 M 144 (LX.5 or LC only)**

Block Orientation

L R

Left Right

Cable Exit Direction

SC ultra polish SC ultra polish, zirconia sleeve SC 8 angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8 angled polish ST ultra polish E-2000 angled polish LX.5 ultra polish (144 only) LX.5 angled polish (144 only) LC ultra polish (144 only)
OR

7 ZB
ZC ZD AA BA CA 2A VA DA FH GA HA MA JA KA EG FJ
OR

4 U Upward
D Downward Adapter/Connector #1 Multimode (62.5/125) 9 A 5 Y P SC FC ST LX.5 (144 only) LC (144 only)

72-fiber stranded 96-fiber stranded 144-fiber stranded 12-fiber stranded 24-fiber stranded 36-fiber stranded 48-fiber stranded 72-fiber stranded 96-fiber stranded 144-fiber stranded 12-fiber ribbon 24-fiber ribbon 36-fiber ribbon 48-fiber ribbon 72-fiber ribbon 96-fiber ribbon 144-fiber ribbon

100571

OR

Connector #2 Singlemode

IFC Type Multimode Glass Type (62.5/125) Corning AM 12-fiber stranded Corning BM 24-fiber stranded Corning DM 36-fiber stranded Corning 2M 48-fiber stranded Corning VM 72-fiber stranded Corning WM 96-fiber stranded Corning YM 144-fiber stranded Glass Type Pirelli Pirelli Pirelli Pirelli Pirelli

0 7 8 L 2 3 Q 4 V N X K

No connector/stub end SC ultra polish SC ultra polish, zirconia sleeve SC 8 angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8 angled polish ST ultra polish E-2000 angled polish LX.5 ultra polish (144 only) LX.5 angled polish (144 only) LC ultra polish (144 only)
OR

OSP Cable Type Singlemode VT VW EN FL FM 72 fiber stranded dielectric 96-fiber ribbon dielectric 96-fiber stranded dielectric 144-fiber stranded dielectric 144-fiber ribbon dielectric

10/03

Other cable types are available upon request. Please contact your ACD representative.

Connector #2 Multimode (62.5/125) 0 9 A 5 Y P No connector/stub end SC FC ST LX.5 (144 only) LC (144 only)

*House cable will use Corning SMF28, Sumitomo, Alcatel or similar singlemode fiber based on current market availability. ** 144 blocks using style 1, 2, or 3 cannot be used in 26" wide NGF frames

See previous page for definition of variables.


www.adc.com +32-2-712-65-00 +32-2-712-65-42

Next Generation Frame 600 mm Products


Fiber Combination Blocks (FCB)
Fiber Combination Blocks provide a place to terminate pigtails and splice IFC/OSP cables on the frame. The blocks are available with several different adapter types in block configurations of 48-, 72-, or 96-positions. Also, a 144-position FCB is available using an LX.5 or LC adapter. The termination portion of the fiber combination block utilizes sliding adapter packs to gain easy access to connectors on both the front and rear side of the block. The block is available with factory-installed pigtails for easy installation. Splice trays are shipped with the block if ordered with pigtails; otherwise trays must be ordered separately. The block is shipped with a cable clamp for OSP/IFC. The FCB occupies two mounting positions on a frame section. Before ordering, determine the block orientation. FCBs may be ordered with a left orientation (mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame).

100571

600 mm Products
Ordering information follows on next page. Definition of Variables Block Style General adapter type required in the FCB Block Configuration Maximum number of terminations that the FCB will accommodate when fully loaded Block Orientation Vertical column of the frame the FCB is to be mounted on Adapter/Connector Type Specific adapter/connector type required in the FCB Pigtail Type Type of pigtail required Number of Pigtail Assemblies Number of pigtails to be pre-installed in the FCB Splice Chip Type of splice chip required for splice trays 1 2 3 4 5 6 7

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

10

Next Generation Frame 600 mm Products


Fiber Combination Blocks (FCB)
Catalog Number NGF-CB 2

Pigtail Type Adapter Type Singlemode

44

600 mm Products

Block Style 1 1 SC 2 FC/ST 3 E-2000 4 LX.5 /LC Block Configuration 2 A 48 B 72 C 96 M 144 (LX.5 or LC only) 1 Block Orientation 3 L Left R Right

7 8

SC ultra polish SC ultra polish, zirconia sleeve L SC 8 angled polish 2 FC ultra polish 3 FC ultra polish, zirconia sleeve Q FC 8 angled polish 4 ST ultra polish V E-2000 angled polish N LX.5 ultra polish (144 only) X LX.5 angled polish (144 only) K LC ultra polish (144 only) Adapter/Connector Type Multimode (62.5/125) A 5 9 Y P FC ST SC LX.5 (144 only) LC (144 only)

0 1 2 4 5

No pigtails 12-fiber pigtail 12-fiber stranded Maxi-Strip 8-fiber pigtail 12-fiber ribbon

Number of Pigtail Assemblies

6 XX Number of assemblies
Splice Chip

OR

0 1 2 3 6 7 8 9 4

Empty Bare fusion Heat shrink fusion Mechanical (Elastomeric) Nortel QPAK Swiss ANT Rotary FibrLok 16 position heat shrink fusion

100571

1 144-termination block requires the use of either: Mechanical (elastomeric) splice tray when using mass fusion ribbon splicing Nortel QPAK splice tray when using single fiber heat shrink fusion splicing 144 blocks using block style 1, 2, or 3 cannot be used in 26" wide NGF frames

Splice Trays For Fiber Combination Block


Catalog Number FST - DRS -

10/03

Splice Tray Type Number of Splices

2 00
FT HS MT NT ANT RT 3M

1 12
24

12 splices 24 splices

Note: For LX.5 FCB with 12 fiber ribbon pigtails, select mechanical splicing only. For LX.5 FCB with 12 fiber stranded pigtails select Nortel QPAK (compatible with heat shrink fusion), bare fusion or Swiss ANT only.

Empty tray* Bare fusion Heat shrink fusion Mechanical (elastomeric) Nortel QPAK Swiss ANT Rotary FibrLok

* Maximum size of chip allowed in empty tray: .3"H x 2.5"W x 3.6"L

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

11

Next Generation Frame 600 mm Products


Sliding Adapter Packs
Sliding adapter packs house groups of fiber optic adapters and are mounted in Fiber Termination Blocks to provide easy access to connectors. Sliding adapter packs are available with SC, FC, ST, E-2000, LX.5 and LC adapters. The adapters come in packs of two, four, six and eight depending on the adapter type and the desired termination density. See table below for configuration guidelines.
Sliding Adapter Pack Configuration Guidelines Block Configuration Adapter Type SC, FC, ST, E-2000 SC, E-2000 FC, ST SC, E-2000 FC, ST SC, FC, ST, E-2000 LX.5 SC, FC, E-2000, LX.5, LC Adapter Pack Configuration 2 Pack / 2 Pack / 6 Pack 2 Pack / 8 Pack 4 Pack / 12 Pack 6 Pack / 2 Pack 4 Pack 6 Pack 4 Pack 6 Pack Adapter Pack Option B (shown below) A (shown below) E (shown below) F (shown below) G (shown below) J (not shown below) H (not shown below) K (not shown below)

100571

600 mm Products

48-Position 72-Position 72-Position 96-Position 96-Position 96-Position 144-Position (block code'E') 144-Position (block code'M')

Option A (SC shown)

Option B (FC shown)

Option E (ST shown)

Option F (E-2000 shown)

Option G (FC shown)

Option H (LX.5 only)

Catalog Number NGF- SAP Adapter Type Singlemode 0 0 0

10/03

Adapter Pack Option* A B E F G H J K 2 pack/4 pack 2 pack/2 pack 6 pack 2 pack/6 pack 8 pack 12 pack (LX.5 block code "E" only) 4 pack / 4 pack 6 pack / 6 pack (all block code "M" blocks)

7 8 L 2 3 Q 4 V N X K

SC ultra polish Adapter Type SC ultra polish,zirconia sleeve Multimode SC 8 angled polish SC 9 FC ultra polish OR A FC FC ultra polish, zirconia sleeve ST 5 FC 8 angled polish LX.5 Y ST ultra polish (144 only) E-2000 angled polish LX.5 ultra polish (144 only) LX.5 angled polish (144 only) LC ultra polish (144 only)

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

12

Next Generation Frame 600 mm Products


Value-Added Module System Chassis
ADCs Next Generation Frame (NGF) Value-Added Modules are designed to support emerging circuit requirements. This high-density fiber frame solution provides unlimited expansion while optimizing fiber cable management. The NGF system uses Mini ValueAdded Modules to incorporate optical splitters for circuit monitoring and video distribution. Mini Value-Added Modules can also be configured with wavelength division multiplexing capabilities to increase transmission capacity over existing fiber lines. Various input and output interface options are available.

600 mm Products

Features:
Enclosed plug-in modules Optical components are protected from physical and environmental damage Flexible platform Modules can be created for new applications quickly and easily to meet customer requirements Monitor and/or test Enables providers to troubleshoot networks without forcing disruption of service Custom configurations Custom splitter configurations available upon request

VAM Chassis
100571
The NGF VAM chassis is designed to mount on all standard NGF frame styles and is interchangeable with termination, splice, and storage modules. Each chassis accommodates up to twelve Mini-VAM modules.

10/03

Catalog Number NGF - TB Block Style 1 SC 2 FC/ST 3 E-2000 D Cable Exit Direction (Rear) Upward U D Downward Block Orientation L Left R Right
* NGF VAMs with LX.5 or LC adapters can be placed in any of these block styles. Please contact ADC Technical Assistance Center with any questions. Ordering of information for value-added modules starts on page 54.

NGF VAM Chassis

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

13

Next Generation Frame 600 mm Products


Fiber Optic Terminal Jumper Storage Bay

600 mm Products

2.2 m

300 mm

600 mm

100571

Front ISO View

Front View (NGF-ACCFOTSB300 Shown)

Side View

Ordering Information
Description FOT storage bay for 600 mm FMDF lineups FOT storage bay for 600 mm F3MDF lineups (not shown) Dimensions 2.2 m x 300 mm x 600 mm 2.2 m x 300 mm x 480 mm Catalog Number NGF-ACCFOTSB300 NGF-F3ACCFOTSB300

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

14

Next Generation Frame 600 mm Products


Equipment Bay
The NGF Equipment Bay provides a mounting location for 19-inch rack mount equipment within an FMDF lineup. The equipment deployment in the bay can include video transmitters, RF Splitter/Combiners, or Remote Fiber Test Systems. NGF Equipment Bays are available for FMDF lineups (600 mm deep) and F3MDF lineups (480 mm deep).

600 mm Products

2.2 m

600 mm 600 mm

NGF-ETSIEB6060-19

Ordering Information
Description Dimensions 2.2 m x 600 mm x 600 mm Catalog Number NGF-ETSIEB6060-19

100571

Equipment bay for FMDF lineups For 19" (48.26 cm) equipment (maximum equipment width) (36) rack unit mounting spaces available (EIA hole spacing) Equipment bay for F3MDF lineups For 19" (48.26 cm) equipment (maximum equipment width) (36) rack unit mounting spaces available (EIA hole spacing)

2.2 m x 600 mm x 480 mm

NGF-ETSIF3EB6048-19

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

15

Next Generation Frame 600 mm Products


Accessories End Guard
The end guard provides protection for the fibers entering and exiting frames at the ends of a lineup.
Ordering Information
Description FMDF end guard, 600 mm deep F3MDF end guard, 480 mm deep Catalog Number NGF-ETSIACCEG NGF-ETSIF3ACCEG

600 mm Products

Cable Clamp Kits


Cable clamp kits are available for securing IFC/OSP cable or equipment (FOT) jumpers on the rear of the FTB.
Ordering Information Description Cable clamp kit for FOT patch cords included with Fiber Termination Blocks loaded with adapters only Cable clamp kit for IFC/OSP cables included with Fiber Termination Blocks with IFC NGF-ACCCLMP08 Catalog Number NGF-ACCCLMP04

Rack Installation Kits


Ordering Information
Description Rack installation kit for concrete floor, kit includes: (2) M8 bolts, 90 mm (4) M8 nuts (8) flat washers (4) lock washers shims and anchor plates Rack installation kit for raised floor, kit includes: (4) threaded rods M12 x 1 m (12) heavy nuts, lock and flat washers (4) nuts with springs, M12 (2) 1.8 m unistrut (1) anchor kit Catalog Number RAC-MX0616

10/03

100571

RAC-MX0615

AC Outlet Kits
Please contact your ADC representative for catalog numbers

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

16

OMX Optical Distribution Frame


Introduction
Growth in the telecommunications industry has driven widespread deployment of optical fiber. As the number of installed fibers grows, the capability of a service providers optical distribution frame to handle large amounts of fiber becomes crucial. Also, office floor space is at a premium. Saving floor space by increasing the optical distribution frame density can provide significant cost-savings to the service provider. At the same time, service providers require a flexible optical distribution frame, which enables them to quickly respond to the changing needs of their customers. These key factors have driven the increased demand for a high-density, modular, front access optical distribution frame.

600 mm Products

ADC has developed the OMX optical distribution frame to meet these demands. Designed with total front access, the OMX can be installed back-to-back or against a wall to save valuable office floor space. This high-density frame terminates and splices up to 576 fibers in a 600 mm x 300 mm footprint and 864 in a 800 mm x 300 mm footprint. The OMX fiber frame protects fiber cable and connections through use of ADCs patented angled adapter/retainers and design features that maintain correct bend radius throughout the frame. Adding signal management and enhancement functions, such as splitters, couplers and wavelength division multiplexers, optimizes the value of your fiber network by providing nonintrusive access to the optical signal for monitoring and testing signal integrity.

Features and Benefits


Modular solution Provides greater flexibility for a variety of applications - Saves costs by standardizing on one flexible solution High density solution Accommodates up to 576 terminations and splices within 600 mm x 300 mm footprint and 864 in a 800 mm x 300 mm footprint - Saves valuable floor space Total front access frame Allows installation back-to-back or against a wall - Saves valuable floor space Superior cable management Protects cables and connectors; reduces reconfiguration time - Saves maintenance costs, improves reliability Completely enclosed and lockable Provides additional fiber protection and security - Improves network reliability through controlled access to fibers

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

17

OMX Optical Distribution Frame


The OMXs modular design provides flexibility to meet the specific needs of the service provider. Each solution will be a combination of the following parts.

OMX Frame
The OMX frame is 600 mm x 300 mm and has ten mounting positions for the termination, splice and jumper storage modules. The OMX 800 frame is 800 mm x 300 mm and also has ten mounting positions for the termination, splice and jumper storage modules.

600 mm Products
10/03 100571

OMX Termination Module


The OMX termination modules are available with 72, 96, or 144 adapters. These modules can be ordered with adapters only or preterminated with either intrafacility fiber cable (IFC), outside plant (OSP) cables, or pigtails for ease of installation. The modules are available with SC, FC, ST, E-2000 and LX.5 connector/adapter styles.

OMX Splice Module


The OMX splice module provides protection and a mounting location for ADCs round splice trays. Each splice module is two mounting positions tall and holds 24 splice trays. Each splice tray can house up to 24 splices.

OMX Slack Storage Solutions


The OMX jumper storage module enables storage of fiber-optic jumper slack within an OMX frame. Each jumper storage module is one module position tall. The Interbay Management Panel provides off-frame storage of jumper slack. ADC recommends the use of 2 mm patch cords to maximize the cable management potential of the OMX.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

18

OMX Optical Distribution Frame


Frame Section
The OMX frame section provides mounting locations for termination, splice and storage modules. It is a completely front-facing frame; all mounting, maintenance and cable access is done on the front of the frame. A lower trough allows multiple frames to be mounted in a continuous lineup. The frame is shipped with lockable front doors. Preconfigured bays are available; please contact your ADC representative for ordering information.

100571

600 mm Products

OMX 600 Frame Section Front ISO View

OMX 800 Frame Section Front ISO View

Ordering Information
Description OMX 600 frame section OMX 800 frame section Dimensions (HxWxD) 2200 x 600 x 300 mm 2200 x 800 x 300 mm Catalog Number MX6-TSF6030 MX6-TSF8030

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

19

OMX Optical Distribution Frame


Termination Module with Adapters Only
The OMX termination module with adapters only is available with 72, 96 or 144 adapters. Modules may be ordered with a left orientation (mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame). ADC recommends the use of 2 mm patch cords to maximize the cable management potential of the OMX. Block configuration D can only be mounted in the OMX 800.

600 mm Products

72 position

Catalog Number
MX6-TM Block Configuration A 72-position B 96-position C 144-position (LX.5 only) D 144-position (OMX 800 only) Adapter Type Singlemode 7 Ultra PCSC L Angled SC 8 2 Ultra PCFC Q Angled FC 8 4 Ultra PCST V Angled E-2000 8 X LX.5 8 Ultra PCSC, zirconia sleeve 3 Ultra PCFC, zirconia sleeve OR Adapter Type Multimode (62.5/125) 9 SC A FC 5 ST Y LX.5 00 Block Orientation L Left R Right

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

20

OMX Optical Distribution Frame


Termination Module with Pigtails
The OMX preterminated pigtail modules are available with either stranded or ribbon preterminated fiber bundles. The modules are mounted on the frame and the fiber bundles are then routed directly to the splice section of the OMX frame. This makes installation of the modules quick and easy, saving valuable installation time. Preterminated pigtail modules may be ordered with a left orientation (mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame). ADC recommends the use of 2 mm patch cords to maximize the cable management potential of the OMX. Block configuration D can only be mounted in the OMX 800.
96 position

600 mm Products

Catalog Number

MX6-PM Block Configuration A 72-position B 96-position C 144-position (LX.5 only) D 144-position (OMX 800 only) Connector Type Singlemode 7 Ultra PCSC L Angled SC 8 2 Ultra PCFC Q Angled FC 8 4 Ultra PCST V Angled E-2000 8 X LX.5 8 Ultra PCSC, zirconia sleeve 3 Ultra PCFC, zirconia sleeve OR Connector Type Multimode (62.5/125) 9 SC A FC 5 ST Y LX.5

0 Number of Pigtail Assemblies XX Number of assemblies Pigtail Type 1 12-fiber stranded 2 12-fiber stranded Maxi-Strip 3 12-fiber ribbon 4 8-fiber stranded 5 8-fiber ribbon 6 6-fiber ribbon 7 4-fiber ribbon 8 6-fiber stranded Block Orientation L Left R Right

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

21

OMX Optical Distribution Frame


Termination Module with IFC
The OMX preterminated IFC modules are available with either indoor or outdoor rated cable in ribbon, stranded, loose tube, or Maxi-Strip configurations. All modules are 100% factory tested to guarantee continuity and reliable connections. IFC modules make installation quick and easy, reducing labor costs. IFC modules may be ordered with a left orientation (mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame). ADC recommends the use of 2 mm patch cords to maximize the cable management potential of the OMX. Block configuration D can only be mounted in the OMX 800.

600 mm Products

96 position
Catalog Number
MX6-FM 0

Block Configuration A 72-position B 96-position C 144-position (LX.5 only) D 144-position (OMX 800 only) Adapter/Connector #1 Singlemode 7 Ultra PCSC L Angled SC 8 2 Ultra PCFC Q Angled FC 8 4 Ultra PCST V Angled E-2000 8 X LX.5 8 Ultra PCSC, zirconia sleeve 3 Ultra PCFC, zirconia sleeve Adapter/Connector #1 Multimode (62.5/125) 9 SC A FC 5 ST Y LX.5 Connector #2 Singlemode 0 No connector/stub end 7 Ultra PCSC L Angled SC 8 2 Ultra PCFC Q Angled FC 8 4 Ultra PCST V Angled E-2000 8 X LX.5 8 Ultra PCSC, zirconia sleeve 3 Ultra PCFC, zirconia sleeve OR Connector #2 Multimode (62.5/125) 0 No connector/stub end 9 SC A FC 5 ST Y LX.5 OR

Length in Meters IFC Type Singlemode (Indoor) AA 12-fiber stranded BA 24-fiber stranded CA 36-fiber stranded 2A 48-fiber stranded 7A 54-fiber stranded VA 72-fiber stranded DA 96-fiber stranded FH 144-fiber stranded GA 12-fiber ribbon HA 24-fiber ribbon MA 36-fiber ribbon JA 48-fiber ribbon KA 72-fiber ribbon EG 96-fiber ribbon FJ 144-fiber ribbon KB 72-fiber ribbon EF 96-fiber ribbon FK 144-fiber ribbon MX 72-fiber stranded Maxi-Strip GF 96-fiber stranded Maxi-Strip IFC Type Multimode (Indoor) AM 12-fiber stranded BM 24-fiber stranded DM 36-fiber stranded 2M 48-fiber stranded VM 72-fiber stranded WM 96-fiber stranded Block Orientation L Left R Right Glass Type Corning Corning Corning Corning Corning Corning Corning Corning Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Alcatel Alcatel Alcatel Corning Corning Glass Type Corning Corning Corning Corning Corning Corning

100571

OR

10/03

Contact your ADC representitve for termination modules with outside plant cable.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

22

OMX Optical Distribution Frame


Value-Added Module System Chassis
The OMX VAM chassis is designed to fit into any open chassis location within new or existing OMX 600 optical distribution frames. Each chassis can accommodate a maximum of ten VAM plug-in modules, ten bulkhead plates, ten blank plates or any combination thereof.

600 mm Products

Ordering Information
Description Unloaded chassis - left orientation; accommodates up to 10 modules Dimensions (HxWxD) 14.69" x 8.93" x 11.25" (37.31 x 22.68 x 28.58 cm) Catalog Number MX6-VAMCHAS-L MX6-VAMCHAS-R

Unloaded chassis - right orientation; 14.69" x 8.93" x 11.25" (37.31 x 22.68 x 28.58 cm) accommodates up to 10 modules

100571

Left Chassis

Right Chassis

10/03

Ordering information for value-added modules starts on page 54.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

23

OMX Optical Distribution Frame


Splice Module and Splice Tray Splice Module
The OMX splice module provides mounting positions and protection for 24 splice trays. The splice module is the height of two termination modules. The module may be ordered with a left orientation (mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame). Splice modules must be mounted to the frame starting in the bottom position.

600 mm Products

Ordering Information
Description OMX (24) tray splice module Height = 2 module positions Right orientation Left orientation MX6-24SPNL-R MX6-24SPNL-L Catalog Number

Splice Tray
The round splice tray used in the OMX simplifies installation and maintenance. The tray stores up to three meters of slack allowing the installer to roll the tray away from the frame to perform splicing.

100571

Catalog Number FST-DRS ___ ___ - ___ ___

10/03

Number of Splices 12 16 24 321


1

For 8 fiber ribbon only

Splice Type Empty 00 Bare fusion FT Heat shrink fusion HS Mechanical (elastomeric) MT URCM Universal Raychem Nortel QPAK NT Swiss ANT ANT Rotary RT FibrLok 3M

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

24

OMX Optical Distribution Frame


Frame Accessories OMX Jumper Storage Module
The OMX jumper slack storage module provides for jumper storage functionality within the frame. Up to five jumper storage modules can be mounted on one side of an OMX frame. Jumper storage modules must be mounted to the frame starting in the bottom position.

600 mm Products

Ordering Information
Description OMX 600 jumper storage module (OMX 600 only) OMX 800 jumper storage module (OMX 800 only) Catalog Number MX6-JSM00000 MX6-JSM80000

OMX Interbay Management Panel


The OMX interbay management panel provides slack storage between frames for interconnect or cross-connect jumpers. The Interbay Management Panel is necessary when no jumper storage is provided on the OMX frame itself.
Ordering Information

100571

Description 150 mm OMX interbay management panel 200 mm OMX interbay management panel

Dimensions (HxWxD) 2200 x 150 x 300 mm 2200 x 200 x 300 mm

Catalog Number MX6-IMP150 MX6-IMP200

OMX End Guard


The OMX end guard provides protection for the fibers entering and exiting frames at the ends of a lineup. The end guard attaches directly to the interbay management panel, but does not add to the overall frame width. End guards are not required when ordering splice bays or bays without external interbay management panels. The OMX end guard can be mounted to both the OMX 600 and OMX 800.
Ordering Information
Description OMX end guard Dimensions 2200 x 300 mm Catalog Number MX6-ENDGRD

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

25

OMX Optical Distribution Frame


Frame Accessories OMX Outside Plant Cable Clamp
The OMX cable clamp is used to secure the OSP/IFC cable to the base or top of the frame.
Ordering Information
Description OMX outside plant cable clamp for top entry cables; clamps up to 3 cables OMX outside plant cable clamp for underfloor cable entry Catalog Number OSP-CLPFEC-LG MX6-ACC001

600 mm Products

Rack Installation Kits


Ordering Information
Description Rack installation kit for concrete floor, kit includes: (2) M8 bolts, 90 mm (4) M8 nuts (8) flat washers (4) lock washers shims and anchor plates Rack installation kit for raised floor, kit includes: (4) threaded rods M12 x 1 m (12) heavy nuts, lock and flat washers (4) nuts with springs, M12 (2) 1.8 m unistrut (1) anchor kit Catalog Number RAC-MX0616

RAC-MX0615

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

26

OMX Optical Distribution Frame


Splice Bay
The OMX 600 splice bay is a high-density splice solution, housing up to 1440 splices within a 600 mm x 300 mm footprint. Shipped complete with the necessary cable management, the splice bay features slots which secure and protect the round splice trays. The splice bay can hold up to 60 twelve-fiber splice trays on each vertical. The bay may be ordered for applications in which the cables enter from above or below. The OMX 600 splice bay is shipped with lockable front doors.

600 mm Products

2200 mm

100571

600 mm

300 mm

Front ISO View

Front View MX6-SPL6030-D Shown

Side View

Ordering Information
Description Fully configured splice bay; accommodates up to 1440 splices Cable enters from underfloor Cable enters from top Splice bay cable clamps for OSP cable (maximum cable outer diameter: 1 cm to 2.8 cm for IFC cable (maximum cable outer diameter: .1.27 cm to 2.54 cm) To order splice trays, see page 24. Dimensions 2200 x 600 x 300 mm MX6-SPL6030-1440-D MX6-SPL6030-1440-U FEC-ACCCLMP01 MX6-SPLIFCCLMP Catalog Number

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

27

FL1000 Fiber Termination Products


Two-Door Wall Mount Boxes
The FL1000 two-door, wall mount boxes feature a unique design and many integrated features such as: Multiple, configurable locking options that allow users and service providers separate access for security Acceptance of strength member tie-off hardware Acceptance of cable clamps at each corner Grounding screws, mounting screws, and dust caps are included with each panel. More accessories are available on page 33.

12-Position Termination/Splice Wall Box

600 mm Products

13.0" 3.6"

Strength Member Tie-Off (Optional) Tie Swing-Out Lance Door Splice Tray (Optional)

Swing-Out Door

Designation Label
PNT0

6pak Adapter Plate (Optional With or Without Pigtails) Cable Channel (Optional)

PNT1

11.2"

Splice Deck

Compression Fitting (Optional)

Radius Limiter Cable Clamp (4 Places) (Optional)

24-Position Termination/Splice Wall Box


14.0" Strength Member Tie-Off (Optional) Tie Swing-Out Lance Splice Tray Door (Optional) Swing-Out Door

100571

3.6" Designation Label

6pak Adapter Plate (Optional With or Without Pigtails) 15.1" Splice Deck Compression Fitting (Optional) Cable Channel (Optional) Cable Clamp Radius Limiter (Optional) (4 Places)

10/03

48-Position Termination/Splice Wall Box


Strength Member Tie-Off (Optional) Tie Swing-Out Lance Door Splice Tray (Optional) 17.0" 6.2" Designation Label 6pak Adapter Plate (Optional With or Without Pigtails) Swing-Out Door

17.7" Cable Clamp (Optional) Radius Limiter Splice (4 places)


Deck

Compression Fitting (Optional)

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

28

FL1000 Fiber Termination Products


Two-Door Ordering Information
How to order an FL1000 two-door wall mount box
1. Select wall box type 2. Select 6pak (with or without fiber) not installed in wall mount box (recommended for quicker availability) OR Select 6pak (with or without fiber) installed in wall mount box 3. Select 6pak adapter type (if factory installed, choose placement in the wall mount box 4. Select splice tray with chip 5. Select number of cable clamps (0-9) 6. Select number of compression fittings (0-9) 7. Select number of bonding grounding kits (0-9) 8. Select number of strength member tie-off kits (each wall box accepts 2, maximum) (0-9) 9. Select locks
Catalog Number

600 mm Products

FL1- __ __ __ __ __ __ __ __ - __ __ __ __ __
1 2 3A 3B 3C 3D 3E 4 5 6 7 8 9

Wall Box Type G 2-door, 12-position termination/splice wall box H 2-door, 24-position termination/splice wall box J 2-door, 48-position termination/splice wall box 6paks not Installed into Wall Box (with or without Fiber) 1 Adapters with pigtails (2.0 mm x 3.0 m) Adapters only None/NA OR 6paks Installed into Wall Box (with or without Fiber)* 3 Adapters with pigtails preinstalled into wall box (2.0 mm x 3.0 m) Adapters preinstalled into wall box

Multimode and Singlemode 6pak Adapter/Connector Type 0 Blank N None/NA Singlemode 2 FC ultra polish 4 ST ultra polish 7 SC ultra polish C SC duplex with zirconia sleeves E SC duplex F FC angled polish J SC angled polish K E-2000 angled polish L FC with zirconia sleeves P ST with zirconia sleeves R SC with zirconia sleeves X LX.5 8 LC Multimode 5 ST 9 SC A FC D SC duplex Y LX.5 6 LC

Locks A Two A keys B Two B keys C One A key, one B key D One A key E One B key N None
Numerous locking options are available for separate user and service provider access. Choose the combination appropriate for your securtiy needs.

100571

2 N

Accessories 5 Cable clamp 6 Compression fittings 7 Bonding grounding kit 8 Strength member tie-off
Enter the desired quantity (0-9) above the corresponding accessory.

10/03

Wall-Mount Bulkhead

3 E 3 E
Door Side

3 D 3 D

3 C 3 C

3 A 3 B

Mounting Wall Side

Splice Tray with Chip 1 Bare fusion 2 Heat shrink fusion 3 Mechanical (elastomeric) 4 Rotary 6 FibrLok 7 Nortel QPAK N None
Number of splice trays received depends on amount of 6paks used: 1-2 6paks = 1 splice tray 4 6paks = 2 splice trays 6 6paks = 3 splice trays 8 6paks = 4 splice trays 29

Viewed from Equipment Side

*Use the guide above for placement of factory-installed 6paks. Place the desired connector or adapter type (from guide above) above the corresponding location designation of 3A, 3B, 3C, 3D or 3E. The diagram illustrates the location of each 6pak within the bulkhead.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

FL1000 Fiber Termination Products


Features
Quick installation Compact size Durability Single catalog number ordering Wall boxes come preconfigured (6paks installed) Two-door design allows for separate user/service provider access Numerous locking options Acceptance of strength member tie-off hardware Acceptance of cable clamps or compression fittings at each corner Slack storage on left, splicing or storage on right side of box Available in putty

Two-Door Wall Mount Boxes with MTRJ Connectors

600 mm Products

Catalog Number FL1- __ __ - 0 __ __ __ __ __ __ __ __ __


1 2 3 4 5 6 7 8 9 10 11 12

100571

Box Size 12 12-position (24 fiber connections) 24 24-position (48 fiber connections) 36 36-position (72 fiber connections) 48 48-position (96 fiber connections) 72 72-position (144 fiber connections) 96 96-position (192 fiber connections) Adapter Style M MTRJ (pass through adapters only) S MTRJ workstation jack (putty) B MTRJ secure keyed jack (blue) G MTRJ secure keyed jack (green) H MTRJ secure keyed jack (yellow) W MTRJ secure keyed jack (red)

Fiber Connections* 012 12 024 24 036 36 048 48 072 72 096 96 144 144 192 192 Type 1 2 3 4 6 7 8 N of Splice Tray Bare fusion Heat shrink Mechanical Rotary Fibrlok Nortel QPAK Raychem None**

Locks N None A (2) key A B (2) key B C (1) key A, (1) key B D (1) key A E (1) key B Accessories*** 8 Cable clamp 9 Compression fittings 10 Bonding/grounding 11 Strength member tie-off

10/03

* Each position = 2 fiber connections (e.g., 24-position panel fully loaded with MTRJ = 48 fiber connections). ** For interconnect only applications; right side of box can be used as slack storage. *** Select number of each as needed. Qty 0-9. Dimensions 12-position 24-position 36-position 48-position 72-position 96-position HxWxD 15.5" 15.5" 23.0" 23.0" 23.0" 31.0" x x x x x x 20.0" 20.0" 22.2" 22.2" 22.2" 22.2" x x x x x x 4.1" 4.1" 5.5" 5.5" 7.0" 7.0"

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

30

FL1000 Fiber Termination Products


One-Door Wall Mount Boxes
The FL1000 one-door, wall mount boxes feature a unique design and many integrated features such as: Numerous cable tie points within the panels Ability to accept hasp-style locks Acceptance of cable clamps at each corner Grounding screws, mounting screws, and dust caps are included with each panel. More accessories are available on page 33.

12-Position Termination/Splice Wall Box

600 mm Products

Designation Label

Swing-Out Door

Splice Tray Shown With Cover Removed (Optional)

Compression Fitting (Optional) 7.8" 6pak Adapter Plate (Optional, With or Without Pigtails) 10.2" (25.96 cm) Cable Clamp Grounding Kit Mounting Holes

1.0" 19.8" 12.0"

3.58" 1.2" (9.1 cm)

Tie Lance Radius Limiter Splice (4 Places) Deck

24-Position Termination/Splice Wall Box


Designation Label Swing-Out Door Splice Tray Shown With Cover Removed (Optional) Compression Fitting (Optional) 8.4" 6pak Adapter Plate (Optional, With or Without Pigtails) 15" (38.1 cm) Cable Clamp Tie Lance Radius Limiter Splice Deck (4 Places) Grounding Kit Mounting Holes 21.4" 13.0"

100571

3.58" 1.2" (9.1 cm)

10/03

48-Position Splice Wall Box


Designation Label Swing-Out Door Splice Tray Shown With Cover Removed (Optional) Compression Fitting (Optional) 8.4" Grounding Kit Mounting Holes 15" (38.1 cm) Cable Clamp 1.0" 21.4" 13.0"

3.58" 1.2" (9.1 cm)

Tie Lance

Radius Limiter Splice (4 Places) Deck

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

31

FL1000 Fiber Termination Products


One-Door Ordering Information
How to order an FL1000 one-door wall mount box
1. Select wall box type 2. Select 6pak (with or without fiber) not installed in wall mount box OR Select 6pak (with or without fiber) installed in wall mount box 3. Select 6pak adapter type (if factory installed, choose placement in the wall mount box) 4. Select splice tray with chip 5. Select number of cable clamps (0-9) 6. Select number of compression fittings (0-9) 7. Select number of bonding grounding kits (0-9)

600 mm Products

Catalog Number FL1- __ __ __ __ __ __ N N __ - __ __ __ 1 2 3A 3B 3C 3D 4 5 6 7

Wall Box Type A 1-door, 12-position termination/splice wall box B 1-door, 24-position termination/splice wall box C 1-door, 48-position splice-only wall box 6paks not Installed into Wall Box (with or without Fiber) 1 Adapters with pigtails (2.0 mm x 3.0 m) Adapters only None/NA OR 6paks Installed into Wall Box (with or without Fiber)* 3 Adapters with pigtails preinstalled into wall box (2.0 mm x 3.0 m) Adapters preinstalled into wall box

Multimode and Singlemode 6pak Adapter/Connector Type 0 Blank N None/NA Singlemode 2 FC ultra polish 4 ST ultra polish 7 SC ultra polish C SC duplex with zirconia sleeves** E SC duplex** F FC angled polish J SC angled polish K E-2000 angled polish L FC with zirconia sleeves P ST with zirconia sleeves R SC with zirconia sleeves X LX.5 8 LC Multimode 5 ST 9 SC D SC duplex** A FC Y LX.5 6 LC
Wall-Mount Bulkhead

Accessories 5 Cable clamp 6 Compression fittings 7 Bonding grounding kit Enter the desired quantity (0-9) above the corresponding accessory. Splice Tray with Chip 1 Bare fusion 2 Heat shrink fusion 3 Mechanical (elastomeric) 4 Rotary 6 FibrLok 7 Nortel QPAK N None Number of splice trays received depends on amount of 6paks used: 1-2 6paks = 1 splice tray 3-4 6paks = 2 splice trays Wall Box Type C = 4 splice trays

100571

2 N

10/03

*Use the guide to the right for placement of factory-installed 6paks. Place the desired connector or adapter type (from guide above) above the corresponding location designation of 3A, 3B, 3C or 3D. The diagram illustrates the location of each 6pak within the bulkhead. **Requires zip cable
Door Side

3 C 3 D
i

3 A 3 B
df

Mounting Wall Side

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

32

FL1000 Fiber Termination Products


6pak Adapter Packs
Flexibility for future growth: To add capacity to an existing FL1000 panel, simply order the appropriate 6pak.
6paks without fiber Multimode Catalog Number (62.5/125) SC FL2-6PMMSC FL2-6PMMDSC Duplex SC FL2-6PMMST ST FL2-6PMMFC FC FL2-6PMMLX LX.5 FL2-6PMMLC LC Singlemode FL2-6PSMSC SC FL2-6PSMDSC Duplex SC FL2-6PSMST ST FL2-6PSMFC FC FL2-6PSMSC-Z SC (with zirconia sleeve) FL2-6PSMDSC-Z Duplex SC (with zirconia sleeve) FL2-6PSMST-Z ST (with zirconia sleeve) FL2-6PSMFC-Z FC (with zirconia sleeve) FL2-6PSMASC SC angled 8 FL2-6PSMAFC FC angled 8 FL2-6PSMAE2 E-2000 angled 8 FL2-6PSMALX LX.5 LC FL2-6PSMLC 6paks with fiber Multimode (62.5/125) SC Duplex SC ST FC LX.5 LC Singlemode SC Duplex SC ST FC SC (with zirconia sleeve) Duplex SC (with zirconia sleeve) ST (with zirconia sleeve) FC (with zirconia sleeve) SC angled 8 FC angled 8 E-2000 angled 8 LX.5 LC Catalog Number FL1-6P9BC003 FL1-6PDBC003 FL1-6P5BC003 FL1-6PABC003 FL1-6PYBC003 FL1-6P6BC003 FL1-6P7SC003 FL1-6PESC003 FL1-6P4SC003 FL1-6P2SC003 FL1-6PRSC003 FL1-6PCSC003 FL1-6PPSC003 FL1-6PLSC003 FL1-6PJSC003 FL1-6PFSC003 FL1-6PKSC003 FL1-6PXBC003 FL1-6P8SC003

600 mm Products

6pak without fiber

6pak with fiber

Accessories
Ordering Information
Description Compression fitting Radius limiters (set of 2 for use with rack mount panels) Strength member tie-off kit NEMA box access tool Cable clamp Bonding grounding kit Lock and Key Type A Lock and Key Type B Mini-splice trays (used only in 12-position, wall mount box) Bare fusion Heat shrink fusion Rotary FibrLok Northern Telecom QPAK Standard splice trays Bare fusion Heat shrink fusion Mechanical (Elastomeric) Rotary FibrLok Northern Telecom QPAK Raychem universal chip Catalog Number FL1-ACC001 FL1-ACC002 FL1-ACC003 ACE/AGX-KEY FL2-ACC007 FL2-ACC006 IPA-K1 IPA-K2

100571

FL1-M-FT FL1-M-HS FL1-M-RT FL1-M-3M FL1-M-NT FST-FT FST-HS FST-MT FST-RT FST-3M FST-NT FST-RCM

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

33

FL2000 System
Introduction

Single Fiber Access

Swing-out Bulkhead Allows Full Access

FL2000 Rack Mount Termination Panel (Empty)

600 mm Products

The FL2000 System is a flexible, modular and economical series of fiber products designed for mounting into ETSI cabinets with either 19" or ETSI mounting.

Features
A complete line of modular panels and boxes, developed for cabinet, rack and wall mounting. Fully adaptable for large or small main distribution frame (MDF), intermediate distribution frame (IDF) or telephone closet (TC) applications. Designed for 19-inch (48.26 cm) EIA rack or cabinet environment found in many enterprise networks; optional brackets are available to accommodate ETSI rack or cabinet mounting. Provides termination, splicing and storage capabilities for in-building cables, outside plant cables and fiber optic terminal (FOT) equipment patch cords. Modular design offers maximum flexibility to satisfy both current needs and future growth requirements. A full line of options and accessories ensures compatibility with existing optical equipment. FL2000 systems accommodate Value-Added Modules, adding flexibility and functionality to the optical transport systems. Splitters, wavelength division multiplexers (WDMs) and other optical components can be easily incorporated. All FL2000 panels and boxes accommodate the modular FL2000 6pak plug-ins. 6paks are available in all connector styles and can be ordered as needed. ADCs patented removable angled retainers allow easy access for single fiber maintenance. FL2000 panels and boxes feature superior vertical cable protection and management. Rack mount panels are hinged on one side, allowing full access to the rear of the front plate and the interior of the panel. Rack mount panels are equipped with mounting brackets to provide 12.7cm (5-inch) recess mounting; mounting brackets are available for virtually any mounting application. Rack mount panels can be wall mounted. The new FL2000 splice wheel allows easy roll-up of pigtail and buffer tube lengths and superior bend radius protection.

FL2000 Rack Mount Termination Panel with IFC

100571

FL2000 Rack Mount Termination/Splice Panel (Empty)

10/03

6pak Adapter Packs

The FL2000 splice deck is available to complete existing installations.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

34

FL2000 Rack or Cabinet Mount Panels


Preconfigured Termination Panels with Multifiber Cable
Features
Available with factory-installed multifiber intrafacility cable (IFC) or OSP cable Panels with multifiber cable attached ship as a single unit with cable clamp installed Panels come equipped with customer specified number of adapters, retainers, connectors, cable type and cable length Panels with multifiber cable attached save costly installation time Simplifies ordering process by allowing one part number for the panel, adapters, connectors and cable Multiple mounting styles available

600 mm Products
100571 10/03

Fiber Panel Data


Termination Preloaded with multifiber cable

Ordering information appears on next page.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

35

FL2000 Rack or Cabinet Mount Panels


Preconfigured Termination Panels with Multifiber Cable
Catalog Number 0 0 __ __ __ __ __ - __ __ __ __ FL2 - __ __ __ __

Panel Type S Singlemode M Multimode Nominal Capacity 1 12-position 2 24-position 3 36-position 4 48-position 7 72-position 9 96-position Connector Style Multimode 9 SC D Duplex SC 5 ST Y LX.51 6 LC1 Singlemode 2 Ultra PCFC L FC with zirconia adapter F FC 8 angled polish 7 Ultra PCSC N SC with zirconia adapter J SC 8 angled polish E Duplex SC 4 Ultra PCST P ST with zirconia adapter K E-2000 8 angled polish X LX.51 8 LC1 1 FC Hybrid (FC connector on front; SC connector on back of bulkhead) 3 ST Hybrid (ST connector on front; SC connector on back of bulkhead) Cable Size 1 2 3 4 7 9 A Z Y X W 12 24 36 48 72 96 144 2 x 12 2 x 24 2 x 36 2 x 48 Panel Height 1.75" (4.45cm) (1RU) 3.5" (8.89 cm) (2RU) 5.25" (13.34 cm) (3RU) 5.25" (13.34 cm) (3RU) 8.75" (22.23 cm) (5RU) 10.5" (26.67 cm) (6RU)

Latch Type 0 1 2 5 6 Standard Hole Plug Screwdriver K1 Lock K2 Lock

600 mm Products

Cable Exit Direction U D Up Down

Mounting Style2 A B C D E F H 19" (48.26 cm) standard (19.6" [49.78 cm] overall) 19" (48.26 cm) maximum (19" [48.26 cm] overall) 19" (48.26 cm) flush mount 23" (58.42 cm) centered 23" (58.42 cm) with oversized VCG ETSI flush mount 600 mm

Length in Meters XXX Cable length (meters) Cable Type Multimode IFC stranded 62.5/125 C Singlemode IFC stranded riser-rated A Plenum stranded F G OSP single armor stranded Indoor-outdoor stranded H OSP dielectric stranded J IFC stranded Maxi-Strip K M IFC ribbon riser-rated OSP dielectric ribbon T OSP armored ribbon L
1

10/03

100571

LX.5 and LC connectors and adapters double the capacity of the panel by terminating two fibers at each adapter. 2 Mounting kit shipped unattached, if other than standard mounting style.

Please see pages 49-51 for mounting instructions.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

36

FL2000 Rack or Cabinet Mount Panels


Preconfigured Termination Panels with Pigtails
10.14" (25.76 cm) 4.95" (12.58 cm) 19.60" (49.79 cm)

5.25" (13.34 cm)

600 mm Products

Catalog Number FL2 1 Panel Type R Termination only Panel Height 1.75" (4.45 cm) (1U) 3.5" (8.89 cm) (2U) 5.25" (13.34 cm) (3U) 5.25" (13.34 cm) (3U) 8.75" (22.23 cm) (5U) 10.5" (26.67 cm) (6U) Number of Ports Loaded Pigtail or Adapter Type A P H R K Y Adapters only 6-fiber softwall bundle 6-fiber Maxi-Strip 12-fiber ribbon 12-fiber softwall bundle2 12-fiber Maxi-Strip2 2 3 0 4 5 6 7 0 - 0 8 9 10 11 0 12

Nominal Capacity 12-position 1 24-position 2 36-position 3 48-position 4 72-position 7 96-position 9 Connector Style

Multimode SC 9 D Duplex SC 5 ST Y LX.51 6 LC1 Singlemode 2 Ultra PCFC L FC with zirconia adapter F FC 8 angled polish 7 Ultra PCSC N SC with zirconia adapter J SC 8 angled polish E Duplex SC 4 Ultra PCST P ST with zirconia adapter K E-2000 8 angled polish X LX.51 8 LC1 1 FC hybrid (FC connector on front; SC connector on back of bulkhead) 3 ST hybrid (ST connector on front; SC connector on back of bulkhead)

Mounting Style3 A B C D E F H 19" (48.26 cm) standard (19.6" [49.78 cm] overall) 19" (48.26 cm) maximum (19" [48.26 cm] overall) 19" (48.26 cm) flush mount 23" (58.42 cm) centered 23" (58.42 cm) with oversized VCG ETSI flush mount 600 mm

10/03

100571

Latch Type 0 1 2 5 6
1

Latch Hole plug Screwdriver K1 lock K2 lock

2 3

LX.5 and LC connectors and adapters double the capacity of the panel by terminating two fibers at each adapter. For use with LX.5 and LC. Mounting kit shipped unattached, if other than standard mounting style.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

37

FL2000 Rack or Cabinet Mount Panels


Preconfigured Termination/Splice Panels with Pigtails
10.14" (25.76 cm) 19.60" (49.79 cm)

4.95" (12.58 cm)


PNT1 PNT1

5.25" (13.34 cm)

600 mm Products

Catalog Number FL2 1 2 3 0 4 5 6 7 8 9 10 11 12

Panel Type C Termination/Splice

Number of Ports Loaded

Number of Splice Decks

Latch Type 0 1 2 5 6 Latch Hole plug Screwdriver K1 lock K2 lock

Nominal Capacity 12-position 1 24-position 2 48-position 4 72-position 7 96-position 9 Connector Style

Panel Height 3.5" (8.89 cm) (2U) 5.25" (13.34 cm) (3U) 8.75" (22.23 cm) (5U) 14.00" (35.56 cm) (8U) 17.50" (44.45 cm) (10U)

Pigtail or Adapter Type A P H R K Y Adapters only 6-fiber softwall bundle 6-fiber Maxi-Strip 12-fiber ribbon 12-fiber softwall bundle 2 12-fiber MaxiStrip2

Number of Cable Clamps 0 2 1 clamp (standard) 2 clamps

100571

Multimode 9 SC D Duplex SC 5 ST Y LX.51 6 LC1 Singlemode 2 Ultra PCFC L FC with zirconia adapter F FC 8 angled polish 7 Ultra PCSC N SC with zirconia adapter J SC 8 angled polish E Duplex SC 4 Ultra PCST P ST with zirconia adapter K E-2000 8 angled polish X LX.51 8 LC1 1 FC hybrid (FC connector on front; SC connector on back of bulkhead) 3 ST hybrid (ST connector on front; SC connector on back of bulkhead)

Mounting Style3 A 19" (48.26 cm) standard (19.6" [49.78 cm] overall) 19" (48.26 cm) maximum (19" [48.26 cm] overall) 19" (48.26 cm) flush mount 23" (58.42 cm) centered 23" (58.42 cm) with oversized VCG ETSI flush mount 600 mm

Splice Type 0 M W 1 2 3 7 8 None or N/A Mechanical (wheel) Heat shrink fusion (wheel) Bare fusion (deck) Heat shrink fusion (deck) Mechanical (deck) Raychem universal (deck) Nortel (deck)

B C D E F H
1

10/03

Splice Type2 M N Mechanical (wheel) Nortel (wheel)

LX.5 and LC connectors and adapters double the capacity of the panel by terminating two fibers at each adapter. For use with LX.5 and LC. Mounting kit shipped unattached if other than standard mounting style.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

38

FL2000 Rack Mount Panels


Features

Termination Panels with MTRJ Connectors

Superior vertical cable protection and management Panels come preconfigured (6paks installed) Panels hinged on one side, allowing full access to the rear of the front plate and the interior of the panel Equipped with mounting brackets to provide 5-inch recess mounting; mounting brackets available for virtually any mounting application Complete line of accessories, including locks for security

600 mm Products

Catalog Number FL2- __ __ __ 0 __ __ __ A 0 - 0 __ __ 0


1 2 3 4 5 6 7 8 9 10 11 12

Panel Type R Termination only rack mount Nominal Capacity/Panel Height 1 12-position putty/1.75" (1RU) 2 24-position putty/3.5" (2RU) 3 36-position putty/5.25" (3RU) 4 48-position putty/5.25" (3RU) 7 72-position putty/8.75" (5RU) 9 96-position putty/10.5" (6RU) A 12-position black/1.75" (1RU) B 24-position black/3.5" (2RU) C 36-position black/5.25" (3RU) D 48-position black/5.25" (3RU) E 72-position black/8.75" (5RU) F 96-position black/10.5" (6RU) Adapter Style M MTRJ (pass through adapters only) S MTRJ workstation jack (putty) B MTRJ secure keyed jack (blue) G MTRJ secure keyed jack (green) H MTRJ secure keyed jack (yellow) W MTRJ secure keyed jack (red)

Fiber Connections* 012 12 024 24 036 36 048 48 072 72 096 96 144 144 192 192
* Each position = 2 fiber connections (e.g., 24position panel fully loaded with MTRJ = 48 fiber connections).

Number of Cable Clamps 0 0 clamps (standard) Latch Type 0 Standard 1 Hole plug 2 Screwdriver 3 K3 lock 4 K4 lock 5 K1 lock 6 K2 lock Mounting Style A 19" standard (19.6" overall) B 19" maximum (19.0" overall) C 19" flush mount D 23" centered E 23" oversized VCG

100571

Pigtail or Adapter Type A Adapters only

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

39

FL2000 Rack or Cabinet Mount Panels


Empty Termination Panels
Features
1.75" (4.45 cm) 8.75" (22.23 cm)

600 mm Products

Mounting - 19-inch (48.26 cm) EIA rack or cabinets, standard 12.7 cm ( 5") recess - Wall mounting option available - Other mounting kits available. Please see pages 49-51. Hinged on left front side; allows full access to rear of front plate and interior of panel FL2000 6pak adapter packs ordered separately Constructed of high strength aluminum Equipped with removable metal doors with Plexiglas windows Designation labels included with each panel Complete line of accessories including locks for security

3.50" (8.89 cm) 10.50" (20.67 cm) 5.25" (13.34 cm)

10.14" (25.76 cm) 4.95" (12.58 cm)

19.60" (49.79 cm)

Fiber Panel Data


Fiber capacity*: 12, 24, 36, 48, 72 & 96 Termination Pigtail storage *All panels can double capacity with LX.5 adapters

5.25" (13.34 cm)

Ordering Information
Description Panel Height Catalog Number1

100571

Rack or cabinet mount termination panel Includes vertical cable management trough 12-fiber capacity 24-fiber capacity 36-fiber capacity 48-fiber capacity 72-fiber capacity 96-fiber capacity Accessories Wall mount bracket Needed for 12 fiber capacity panel only Cable clamp kit One per cable recommended Outer diameter .2" to .8" Outer diameter .7" to 1.0" Cable clamp kit for 12 fiber capacity panel only Bonding/grounding kit For mounting kits and additional accessories, see pages 47-51
1

4.45 cm (1.75") 8.89 cm (3.50") 13.34 cm (5.25") 13.34 cm (5.25") 22.23 cm (8.75") 26.67 cm (10.50")

FL2-12RPNL FL2-24RPNL FL2-36RPNL FL2-48RPNL FL2-72RPNL FL2-96RPNL FL2-ACC008

24-Fiber Capacity

10/03

72-Fiber Capacity FL2-ACC007 FL2-ACC021 FL2-ACC033 FL2-ACC006 96-Fiber Capacity

Panels with right front hinge and VCG are also available, although they are not standard products. To order a panel with right front hinge and VCG , add -R after the catalog number. Example: FL2-12RPNL-R.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

40

FL2000 Rack or Cabinet Mount Panels


Empty Splice Panels
Features
Offers combination of splicing protection and associated fiber/pigtail storage Splice panel can be mounted in conjunction with any FL2000 termination panel or as a stand-alone splice panel Occupies same footprint and offers same mounting options as FL2000 termination panels Accepts the new ADC splice wheel for efficient management of fiber cable and splice protection Accepts the traditional ADC splice deck
10.14" (25.76 cm) 19.60" (49.79 cm)

4.95" (12.58 cm)

3.50" (8.89 cm)

600 mm Products

TOP SIDE

Fiber Panel Data


Fiber capacity: 48, 96, 144 Splice Pigtail storage

CLEAR COVERS

BOTTOM SIDE

SPLICE DECK

Splice Deck with Splice Chip

SPLICE CHIP(S) (HEAT SHRINK SHOWN)

Splice Wheel with Splice Chip

Ordering Information
Description Splice panel for splice wheel (Accepts splice wheel only) 48 fiber capacity 96 fiber capacity 144 fiber capacity Splice wheel with splice chip Heat shrink fusion Mechanical Nortel Splice panel for splice deck for existing installations (Also accepts splice wheel) 48 fiber capacity 96 fiber capacity 144 fiber capacity Splice deck with splice chip for existing installations Heat shrink fusion Mechanical Bare fusion Nortel Cable clamp kit (kit of 1) Outer diameter .2" to .8" (.5 cm to 2 cm) Outer diameter .7" to 1.0" (1.8 cm to 2.54 cm) Panel Height Catalog Number1

3.5" (8.89 cm) 7" (17.78 cm) 8.75" (22.23 cm)

FL2-48SPNL2 FL2-96SPNL2 FL2-144SPNL2 FST-DRS12-HS FST-DRS12-MT FST-DRS24-NT

100571

10/03

3.5" (8.89 cm) 7" (17.78 cm) 8.75" (22.23 cm)

FL2-48SPNL FL2-96SPNL FL2-144SPNL

FL2-RSPLCE-HS FL2-RSPLCE-MT FL2-RSPLCE-FT FL2-RSPLCE-NT FL2-ACC007 FL2-ACC021

For mounting kits and additional accessories, see pages 47-51. 1 Panels with right front hinge and VCG are also available, although they are not standard product. To order a panel with right VCG, add -R after the catalog number. Example: FL2-48SPNL-R.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

41

FL2000 Rack or Cabinet Mount Panels


Empty Termination/Splice Panels
Features
Mounting - 19-inch (48.26 cm) EIA racks or cabinets, standard 5-inch (12.7 cm) recess - Wall mounting option available - Other mounting kits available. Please see pages 49-51 Hinged on left front side for complete access to interior of termination section Ability to quickly and easily configure, utilizing the 6pak assemblies (ordered separately) Complete line of accessories including locks for security Uses ADC splice wheels or splice decks

24-Position

600 mm Products

Fiber Panel Data


Termination Splice Pigtail storage
19.60" (49.79 cm)

48-Position

10.14" (25.76 cm)

4.95" (12.58 cm)

5.25" (13.34 cm)

100571

96-Position

Ordering Information
Description Panel Height 3.5" (8.89 cm) 5.25" (13.34 cm) 8.75" (22.23 cm) 14" (35.56 cm) 17.5" (44.45 cm) Catalog Number1 FL2-12TS350 FL2-24TS525 FL2-48TS875 FL2-72TS140 FL2-96TS175 FST-DRS12-HS FST-DRS12-MT FST-DRS24-NT FL2-RSPLCE-HS FL2-RSPLCE-MT FL2-RSPLCE-FT FL2-RSPLCE-NT

Termination/splice panel 12-position 24-position 48-position 72-position 96-position Splice wheel with splice chip Heat shrink fusion Mechanical Nortel Splice eeck with splice chip Heat shrink fusion Mechanical Bare fusion Nortel
1

10/03

Panels with right front hinge and VCG are also available, although they are not standard product. To order a panel with right front hinge and VCG, add -R after the catalog number. Example: FL2-24TS525-R.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

42

FL2000 Slack Storage Solutions


Fiber Storage Disk
Features
Provides jumper storage for 3 mm patch cords one patch cord per disk Stores 3.8 meters (12.5') of patch cord in each disk
10.14" (25.76 cm) 4.95" (12.58 cm) 19.60" (49.79 cm)

600 mm Products

Fiber Panel Data


Patch cord storage Rack/cabinet mount Wall mount
ROTATE TO REMOVE SLACK

5.25" (13.34 cm)

Ordering Information
Description Fiber Storage Disk 16 disks 24 disks 5.25" x 19" x 10.19" (13.34 x 48.26 x 25.81 cm) 8.75" x 19" x 10.19" (22.23 x 48.26 x 25.81 cm) FL2-16FSD525 FL2-28FSD875 Dimensions (HxWxD) Catalog Number

Fiber Storage Tray


100571
Features
Provides jumper storage for 3 mm patch cords Stores 33 m (110') of patch cord in each tray
10.18 in (25.86 cm) 4.95 in (12.58 cm) 19.60 in (49.79 cm)

Fiber Panel Data


Patch cord storage Rack/cabinet mount

5.25 in (13.34 cm)

10/03

Ordering Information
Description Fiber Storage Tray 6 trays 5.25" x 19" x 10.19" (13.34 x 48.26 x 25.81 cm) FL2-CST60525 Dimensions (HxWxD) Catalog Number

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

43

FL2000 Slack Storage Solutions


Storage Deck Panel
Features
Mounts with FL2000 termination panels to provide jumper storage Wall, rack, or cabinet mount Utilizes unique storage decks for patch cord storage Each storage deck accommodates up to 32 meters (105') of 3 mm cable
10.14" (25.76 cm) 19.60" (49.79 cm)

4.95" (12.58 cm)

3.50" (8.89 cm)

600 mm Products

FL2000 Storage Deck Panel Front View Ordering Information Description Storage deck panels (storage decks ordered separately) 2 storage deck capacity; 3.5" x 19" x 10.19" (8.89 x 48.26 x 25.81 cm) 6 storage deck capacity; 8.75" x 19" x 10.19" (22.23 x 48.26 x 25.81 cm) Storage deck FL2-2RSTORE Catalog Number

FL2-6RSTORE

Storage Deck Top View

FL2-TR2000

100571

Horizontal Interbay Management Panel


Features
Mounts horizontally in a bay to manage jumper storage May be modified for flush or wall mount applications Stores up to 75 meters of cable
4.95" (12.58 cm) 19.60" (49.79 cm)

5.25" (13.34 cm)

10/03

Ordering Information
Description Horizontal interbay management panel Horizontal interbay management panel for 600 mm centered mounting Horizontal interbay management panel for flush mounting Wall bracket for wall mounting Catalog Number FL2-HZSTORE FL2-HZSTORE-600 FL2-HZSTORE-FLMT FL2-HZSTORE-WMNT

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

44

FL2000 6pak Adapter Packs


Features
Completely interchangeable between FL2000 panel and wall box products Can be ordered with all standard types of simplex and duplex single and multimode adapters and connectors Feature ADCs patented removable angled retainers which provide superior fiber management No tools required to install into FL2000 boxes or panels Can be ordered with adapters only, or for quick and easy installation, with preterminated 3 meter (9.84') or 5 meter (16.4') pigtails

6pak (shown with singlemode duplex adapters)

600 mm Products

6pak (shown with multimode duplex adapters)

6pak Blank Plug-In 6pak (shown with singlemode simplex adapters)

Ordering Information
Description Multimode SC ST FC SC (duplex) SC, zirconia ST, zirconia FC, zirconia LX.5 LC Singlemode SC ST FC SC (duplex) FC with 8 angled polish SC with 8 angled polish SC, zirconia ST, zirconia FC, zirconia E-2000, angled polish LX.5 LC Hybrid: FC front, SC back Hybrid: ST front, SC back 6pak blank plug-in Catalog Number

6pak (shown with mulitmode simplex adapters)

FL2-6PMMSC FL2-6PMMST FL2-6PMMFC FL2-6PMMDSC FL2-6PMMSC-Z FL2-6PMMST-Z FL2-6PMMFC-Z FL2-6PMMLX FL2-6PMMLC FL2-6PSMSC FL2-6PSMST FL2-6PSMFC FL2-6PSMDSC FL2-6PSMAFC FL2-6PSMASC FL2-6PSMSC-Z FL2-6PSMST-Z FL2-6PSMFC-Z FL2-6PSMAE2 FL2-6PSMALX FL2-6PSMLC FL2-6PSMFC/SC FL2-6PSMST/SC FL2-6PBLNK

10/03

100571

6pak (shown with singlemode LX.5 adapters)

6pak (shown with multimode LX.5 adapters)

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

45

FL2000 6pak Adapter Packs


Features
Available with preterminated 3 meter (9.84') or 5 meter (16.4') pigtails Pigtails consist of a single outer jacket containing six color-coded 900 m fibers One end of pigtail terminated to chosen connector style and installed into the 6pak adapter pack ADC recommends specific breakouts for panel and wall mount box products Saves installation time

600 mm Products

FL2000 6pak with SC adapters and pigtails

Multimode Pigtails and Adapters


Catalog Number 6 __ __ __ B __ C __ FL2 - 6P __ __ Multimode Connector Style 5 ST 9 SC A FC D Duplex SC Y LX.51 6 LC1 Fiber Size B Multimode 62.5/125 C Multimode 50/125 Length (in meters) 3 m (9.84') pigtail 03W for wall mount boxes 5 m (16.4') pigtail 05R for rack mount panels
1

LX.5 and LC 6paks are loaded with 12 fiber pigtails

100571

Singlemode Pigtails and Adapters


Catalog Number S __ __ 6 __ __ __ FL2 - 6P __ __ Singlemode Connector Style E 2 4 7 F J K X 8 1 3 Duplex SC Ultra PCFC Ultra PCST Ultra PCSC PCFC 8 angled polish PCSC 8 angled polish E-2000 angled polish LX.51 LC1 FC hybrid (FC connector on front; SC connector on back of bulkhead) ST hybrid (ST connector on front; SC connector on back of bulkhead) Length (in meters) 3 m (9.84') pigtail 03W for wall mount boxes 5 m (16.4') pigtail 05R for rack mount panels Fiber Type C D Stranded Maxi-Strip

10/03

Fiber Size S Singlemode


1

LX.5 and LC 6paks are loaded with 12 fiber pigtails

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

46

FL2000 Rack Mount Panels


Accessories
RUBBER GROMMETS CLAMP BRACKET COVER

Locks

CLAMP YOKES (2)

PLATE

NUTS (2)

Cable Clamp Kit

600 mm Products

7'

Blank VCG FL2-BLNKFULL0875

Bonding/Grounding Kit

12" 2.5"

Ordering Information
Description Locks for rack mount panels Key lock #1; includes lock and key #1 Key lock #2; includes lock and key #2 End guards 7' H x 12" W x 29/16" D; right or left side; putty white Lower cable trough 14" H x 19" W x 5" D 7" H x 19" W x 5" D 7" H x 600 mm (23.6") x 5" D Bonding/grounding kit kit of 1 Cable clamp kit kit of 1 Outer diameter .2" to .8" Outer diameter .7 to 1.0" Cable clamp kit For use with 12 fiber termination or termination/splice panels Blank VCG to add cable management to frame not fully loaded 3.5" (8.89 cm) 8.75" (22.23 cm) 10.5" (26.67 cm) Blank VCG with blank panel for aesthetics 3.5" (8.89 cm) 5.25" (13.34 cm) 7.0" (17.78 cm) 8.75" (22.23 cm) 10.5" (26.67 cm) Catalog Number IPA-K1 IPA-K2 UEGP-7PW

End Guard UEGP-7PW

100571

FL2-ACC011 FL2-ACC012 FL2-ACC051 FL2-ACC006 FL2-ACC007 FL2-ACC021 FL2-ACC033

10/03

14" Lower Cable Trough FL2-ACC011

FL2-BLNKVCG0350 FL2-BLNKVCG0875 FL2-BLNKVCG1050 FL2-BLNKFULL0350 FL2-BLNKFULL0525 FL2-BLNKFULL0700 FL2-BLNKFULL0875 FL2-BLNKFULL1050

7" Lower Cable Trough FL2-ACC012

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

47

FL2000 Rack Mount Panels


Accessories
Ordering Information
Description Interbay Management Panel (IMP) for 19" or 23" (48.26 or 58.42 cm) racks 7' x 5" Interbay Management Panels (IMP) and Inner IMPs for 600 mm and 800 mm cabinets and racks E-501-L139 Catalog Number

600 mm Products

Interbay Management Panel E-501-L139

26" (66.04 cm) high IMP for 600 mm racks/cabinets Full IMP for use in 800 x 800 mm cabinet with 19" (48.26 cm) mounting Full IMP to install on rear side of 600 x 600 mm cabinet

FL2-EUROIMP-26-600-A FL2-EUROIMP-67 FL2-EUROIMP-REAR

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

48

FL2000 Mounting Options


19" (48.26 cm) Rack Mounting Standard Mount (as shipped)
Rear Guard Box (optional with some racks) Rack shown for reference 21.88" (55.58 cm)

Features
Panels typically shipped from factory equipped for this mounting
5.00" (12.70 cm) 17.50" (44.45 cm) 18.31" (46.51 cm)

5.00" (12.70 cm)

600 mm Products

19.60" (48.26 cm)

Flush Mount
Features
Panels shipped with - Left-side L bracket - Left-side 2.5" (6.32 cm) wide vertical cable guide (VCG)

Ordering Information

100571

Description Flush Mount Allows 1", 2" or 4" (2.54, 5.08 or 10.16 cm) recess mounting Kit includes: new vertical cable guide and mounting flanges

Panel Height 1.75" (4.45 cm) 3.5" (8.89 cm) 5.25" (13.34 cm) 7" (17.78 cm) 8.75" (22.23 cm) 10.5" (26.67 cm)

Catalog Number FL2-FLMT0175 FL2-FLMT0350 FL2-FLMT0525 FL2-FLMT0700 FL2-FLMT0875 FL2-FLMT1050

10/03

Rear Guard Box (optional with some racks) 1.94" (4.93 cm)

15.912" (40.42 cm)

17.50" (44.45 cm)

18.83" (47.82 cm)

Rack shown as reference

6.65" (16.89 cm) 5.00" (12.70 cm)

5.00" (12.70 cm)

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

49

FL2000 Mounting Options


19" (48.26 cm) Rack Mounting 19" Maximum Mounting
21.88" (55.58 cm) 18.31" (46.51 cm) 19.00 (48.26 cm) RACK SHOWN FOR REFERENCE

REAR GUARD BOX (OPTIONAL WITH SOME RACKS)

17.50" (44.45 cm)

600 mm Products

5.00" (12.70 cm) 10.14" (25.76 cm) 4.95" (12.58 cm)

2.93"

5.00" (12.70 cm)

New VCG with integrated mounting holes

Ordering Information
Description 19" Maximum Allows entire panel to be contained within frame footprint Kit includes: new vertical cable guide with integrated mounting holes Panel Height 1.75" (4.45 cm) 3.5" (8.89 cm) 5.25" (13.34 cm) 7" (17.78 cm) 8.75" (22.23 cm) 10.5" (26.67 cm) 14" (35.56 cm) 17.5" (44.45 cm) Catalog Number FL2-19MAX0175 FL2-19MAX0350 FL2-19MAX0525 FL2-19MAX0700 FL2-19MAX0875 FL2-19MAX1050 FL2-19MAX1400 FL2-19MAX1750

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

50

FL2000 Mounting Options


19" ETSI and 600 mm Mounting 19" ETSI Mounting
20.276" (51.50 cm) 21.22" (53.99 cm) 21.88" (55.58 cm)

3.02" (7.67 cm)

600 mm Products

5.00" (12.70 cm) 4.85" (12.32 cm)

5.00" (12.70 cm)

Ordering Information
Description 19" ETSI Mounting Kit includes mounting brackets Panel Height 1.75" (4.45 cm) 3.5" (8.89 cm) 5.25" (13.34 cm) 7.0" (17.78 cm) 8.75" (22.23 cm) 10.5" (26.67 cm) 14" (35.56 cm) 17.5" (44.45 cm) Catalog Number FL2-ETEB0175 FL2-ETEB0350 FL2-ETEB0525 FL2-ETEB0700 FL2-ETEB0875 FL2-ETEB1050 FL2-ETEB1400 FL2-ETEB1700

600 mm Mounting
100571
Rear Guard Box (Optional with Some Racks) 23.35" (59.31 cm) 15.27" (38.79 cm) 17.72" (45.01 cm) Rack Shown as Reference

4.0" (10.16 cm)

4.0" (10.16 cm)

10/03

3.53" (8.97 cm) 4.95" (12.57 cm)

Ordering Information
Description 600 mm Mounting Kit includes mounting brackets Panel Height 1.75" (4.45 cm) 3.5" (8.89 cm) 5.25" (13.34 cm) 7.0" (17.78 cm) 8.75" (22.23 cm) 10.5" (26.67 cm) 14" (35.56 cm) 17.5" (44.45 cm) Catalog Number FL2-600MM0175 FL2-600MM0350 FL2-600MM0525 FL2-600MM0700 FL2-600MM0875 FL2-600MM1050 FL2-600MM1400 FL2-600MM1750

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

51

FL2000 System

Value-Added Module System Chassis


Accommodates ADC VAM plug-in modules in FL2000 installations 19-inch rack mount Vertical cable guides included
19.0" (48.26 cm) 5.0" (12.7 cm) 10.14" (25.76 cm) 5.0" (12.7 cm) 19.0" (48.26 cm)

5.25" (13.34 cm)

600 mm Products

10.14" (25.76 cm) 10.47" (26.6 cm)

FL2000 VAM 4-Position Chassis

19.6" (49.78 cm) 4.95" (12.57 cm)

5.22" (13.26 cm)

FL2000 VAM 9-Position Chassis


10.15" (25.78 cm)

100571

FL2000 WideVAM 4-Position Chassis

Ordering Information
Description VAM chassis 4 plug-in modules 6 plug-in modules 9 plug-in modules WideVAM chassis Chassis for 19" EIA mounting; accommodates 4 WideVAM plug-in modules Chassis for 19" EIA mounting for 600mm skeleton bay; accommodates 4 WideVAM plug-in modules 5.25" x 19" x 10.14" (13.34 x 48.26 x 25.76 cm) 5.25" x 19" x 10.14" (13.34 x 48.26 x 25.76 cm) FL2-4WVAM3RU FL2-4WVAM3RU-600 5.25" x 19" x 10.14" (13.34 x 48.26 x 25.76 cm) 6" x 19" x 10.14" (15.24 x 48.26 x 25.76cm) 10.5" x 19" x 10.14" (26.67 x 48.26 x 25.76 cm) FL2-4VAM525 FL2-6VAM700 FL2-9VAM105 Dimensions (HxWxD) Catalog Number

10/03

Note: The FL2000 VAM system is designed to accept only front access modules; i.e., all input and output adapters, pigtails and/or bare fibers must be located on the front of the plug-in modules.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

52

Value-Added Module System


4-Inch Chassis 6 Single Plug-In Modules
The 4-inch VAM chassis fits into any 23-inch rack mounting environment. It accommodates a maximum of six plug-in modules, six bulkhead plates, six blank panels or any combination thereof. Not for use in ADCs FDF

Chassis used in Non-ADC Optical Distribution Frame

FVM-23X400

Ordering Information

600 mm Products

Description Unloaded chassis for 23" racks

Dimensions (HxWxD) 4.0" x 23" x 12" (10.16 x 58.42 x 30.48 cm)

Catalog Number* FVM-23X400

3.5-Inch Chassis 4 Single Plug-In Modules


The 3.5-inch VAM chassis fits into any 19-inch rack mounting environment. It accommodates a maximum of four plug-in modules, four bulkhead plates, four blank panels or any combination thereof. Adjustable mounting brackets are provided for 23-inch mounting environments. Not for use in ADCs FDF
FVM-19X350

Ordering Information
Description Dimensions (HxWxD) 3.5" x 19" or 23" x 12" (8.89 x 48.26 or 58.26 x 30.48 cm) Catalog Number* FVM-19X350

100571

Unloaded chassis for 19" or 23" racks

1.75-Inch Chassis 2 Single Plug-In Modules


The 1.75-inch VAM chassis fits into any 19-inch rack mounting environment. It accommodates a maximum of two plug-in modules, two bulkhead plates, two blank panels or any combination thereof. Adjustable mounting brackets are provided for 23-inch mounting environments. Not for use in ADCs FDF
FVM-19X175

10/03

Ordering Information
Description Unloaded chassis for 19" or 23" racks; no front door Dimensions (HxWxD) 1.75" x 19" or 23" x 12" (4.45 x 48.26 or 58.26 x 30.48 cm) Catalog Number* FVM-19X175

* This product is available in black; for this option, simply add -BK to the end of the catalog number. Please contact the Technical Assistance Center with any questions.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

53

Value-Added Module System


Introduction
ADCs Value-Added Connector Module System (VAM System) adds flexibility and functionality to the optical transport system by enabling telecommunications service providers to easily incorporate optical components into the network. This versatile platform lays the foundation for the fiber distribution frame of the future. The VAM System consists of a variety of chassis and optical components that fit into all existing ADC fiber distribution frames and various other mounting environments. Optical components may include:

600 mm Products
100571 10/03

Splitters Wavelength division multiplexers (WDMs) Variable attenuators

Features and Benefits


VAM chassis and modules available for all ADC fiber frames One-stop shop for complete optical transport system requirements Monitor testing Enables providers to troubleshoot networks without forcing disruption of service Enclosed plug-in modules Optical components are protected from physical and environmental damage Angled retainers Maintains minimum bend radius of fiber patch cords Horizontal mounted plug-in modules Modules can be added or removed from the chassis without interfering with existing terminated patch cords Universal mounted plug-in modules No need to order different part numbers for left side or right side mounted modules Extensive product labeling Customers have all the information required for installation and maintenance without referring to the user manual or drawings Flexible platform Modules can be created for new applications quickly and easily to meet customer requirements Module labeling system Schematics are marked on peel-off labels that can be attached to the chassis designation labeling system Custom configurations Custom splitter configurations available upon request, contact ADC

Standard VAM Module

WideVAM Module

OMX VAM Module

LGX-compatible VAM module

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

54

Value-Added Module System


Splitter Modules
Catalog Number

VAM Style VSMStandard VAM for FL2000 and non-ADC frames FLVW-S WideVAM for FL2000 VSMW- WideVAM for non-ADC frames MiniVAM for Next NGF-V Generation Frames* For OMX 600 frames MXVFor LGX-compatible VLMframes Configurations 2 5 Input front, output front Input rear, output front Split Ratio** 2000 1x2 2100 1x2 2200 1x2 2300 1x2 2350 1x2 2400 1x2 2500 1x2 2600 1x2 2700 1x2 2800 1x2 2900 1x2 2950 1x2 2030 2x2 3900 1x3 4900 1x4 5300 1x5 6000 1x6 7000 8000 9000 A110 B111 C112 D113 E114 F115 G116 M132 1x7 1x8 1x9 1x10 1x11 1x12 1x13 1x14 1x15 1x16 1x32 50/50 55/45 60/40 65/35 66.6/33.3 70/30 75/25 80/20 85/15 90/10 95/5 99/1 50/50 33/33/33 25/25/25/25 20/20/20/20/20 16.6/16.6/16.6/ 16.6/16.6/16.6 14.3/14.3/14.3/ 14.3/14.3/14.3/14.3 12.5/12.5/...12.5 11.1/11.1/11.1/...11.1 10/10/10/...10 9.1/9.1/9.1/...9.1 8.33/8.33/8.33/...8.33 7.7/7.7/7.7/...7.7 7.14/7.14/7.14/...7.14 6.66/6.66/6.66/...6.66 6.25/6.25/6.25/...6.25 3.125/3.125/3.125/...3.125

Output Pigtail Length Input Pigtail Length Example (In Meters): 01 = 1 m 10 = 10 m 00 = Adapters only on input and output ports Number of Splitters Single splitter A Dual splitter (2) B Triple splitter (3) C

600 mm Products

Input Connector/Adapter Singlemode 2U 2A 4U 7U 7A 8A LA LU KU 00 FC ultra polish FC angled polish ST ultra polish SC ultra polish SC angled polish E-2000 angled polish LX.5 angled polish LX.5 ultra polish LC ultra polish Bare fiber

100571

OR
Multimode** 2M 2N 5F 5U 9A 9B LM LN PM 00 FC 62.5/125 FC 50/125 ST 50/125 ST 62.5/125 SC 50/125 SC 62.5/125 LX.5 62.5/125 LX.5 50/125 LC 62.5/125 Bare fiber

Output Connector/Adapter Singlemode 2U 2A 4U 7U 7A 8A LA LU KU 00 FC ultra polish FC angled polish ST ultra polish SC ultra polish SC angled polish E-2000 angled polish LX.5 angled polish LX.5 ultra polish LC ultra polish Bare fiber OR

Multimode** 2M 2N 5F 5U 9A 9B LM LN PM 00 FC 62.5/125 FC 50/125 ST 50/125 ST 62.5/125 SC 50/125 SC 62.5/125 LX.5 62.5/125 LX.5 50/125 LC 62.5/125 Bare fiber

10/03

*MiniVAMs are not available with split ratios above 1x8 nor can they be configured with three splitters. They are not available with E-2000 connectors/adapters **VAMs with multimode connectors/adapters can only be configured with 90/10 or uniform split (50/50) ratios. See page 58 for configuration illustrations. Please contact ADC for specifications and available split ratios.

Multimode couplers designed to be used with LED sources only. If you are using a different source, please contact the ADC Technical Assistance Center for the appropriate solution.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

55

Value-Added Module System


Wavelength Division Multiplexer Modules
Catalog Number

VAM Style WDMStandard VAM for FL2000 and non-ADC frames FLVW-W WideVAM for FL2000 WDMW- WideVAM for non-ADC frames NGF-W MiniVAM for Next Generation Frames* MXV-W For OMX 600 frames VLM-W For LGXcompatible frames Configuration 2 MUX front, DEMUX front 5 MUX rear, DEMUX front Mux Port Connector/Adapter 2U 2A 4U 7U 7A 8A LA LU KU 00 FC ultra polish FC angled polish ST ultra polish SC ultra polish SC angled polish E-2000 angled polish LX.5 angled polish LX.5 ultra polish LC ultra polish Bare fiber Module Configuration A Single B Dual C Triple Isolation* 1 Standard 2 High 3 Very High

Demux Port Pigtail Length Mux Port Pigtail Length Example (In Meters): 01 = 1 m 10 = 10 m 00 = Adapters only on mux and demux ports Wavelength A B C E F 1310 (1)/1550 (2) 1533 (1)/1557 (2) 1310/1533/1557 1550 (1)/1625 (2) 1310 (1)/1625 (2)

600 mm Products

WDM Type (1; 2) A Unidirectional multiplexer C Unidirectional demultiplexer E Bidirectional 1 Tx/2 Rx G Bidirectional 1 Rx/2 Tx J 45 dB isolation, pass 1310 K 45 dB isolation, pass 1550 L (Dual only) unidirectional multiplexer, unidirectional demultiplexer** M (Dual only) bidirectional 1 Tx/2 Rx, bidirectional 2 Tx/1 Rx Demux Port Connector/Adapter 2U 2A 4U 7U 7A 8A LA LU KU 00 FC ultra polish FC angled polish ST ultra polish SC ultra polish SC angled polish E-2000 angled polish LX.5 angled polish LX.5 ultra polish LC ultra polish Bare fiber

*MiniVAMs are not available with E-2000 connectors/adapters **WDM Type L includes (1) unidirectional multiplexer (standard isolation) and (1) unidirectional demultiplexer (isolation specified by next character)

100571

10/03

In the ordering charts, the abbreviation mux references the multiplexed side of the WDM, the side where two optical signals co-exist on one fiber. The abbreviation demux references the demultiplexed side of the WDM, the side where each signal appears on its own fiber. Both unidirectional and bidirectional WDMs are available as shown below.
UNIDIRECTIONAL MULTIPLEXER 1310 DEMUX 1550 1310 1550 MUX MUX UNIDIRECTIONAL DEMULTIPLEXER 1310 1550 1310 DEMUX 1550 BIDIRECTIONAL TRANSMISSION 1310 DEMUX 1550 1310 1550 MUX DEMUX 1550 1310 1310 1550 MUX

See page 58 for configuration instructions. Please contact ADC for specifications.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

56

Value-Added Module System


Monitor Modules
Catalog Number VAM Style
VMMStandard VAM for FL2000 and non-ADC frames WideVAM for FL2000 WideVAM for non-ADC frames MiniVAM for Next Generation Frames* For OMX 600 frames For LGXcompatible frames

Monitor pigtail length Number of Circuits per VAM 1 2 3 1 circuit 2 circuits 3 circuits Output pigtail length Input pigtail length Example (in meters): 01 = 1 m 10 = 10 m 000 = Adapters only on input, output and monitor ports Module Style Dual monitor cross-connect with attenuator*** B Customer premises D Dual monitor cross-connect J Dual monitor cross-connect 1 *** This style cannot be used in NGF-M modules. Monitor Connector Multimode** Type Singlemode 2M FC 62.5/125 2U FC ultra polish OR 2N FC 50/125 2A FC angled polish SF ST 50/125 4U ST ultra polish 5U ST 62.5/125 7U SC ultra polish 9A SC 50/125 7A SC angled polish 9B SC 62.5/125 8A E-2000 angled polish LM LX.5 62.5/125 LA LX.5 angled polish LN LX.5 50/125 LU LX.5 ultra polish PM LC 62.5/125 KU LC ultra polish 00 Bare fiber 00 Bare fiber Output Connector Type Singlemode 2U FC ultra polish 2A FC angled polish 4U ST ultra polish 7U SC ultra polish 7A SC angled polish 8A E-2000 angled polish LA LX.5 angled polish LU LX.5 ultra polish KU LC ultra polish 00 Bare fiber

FLVW-M VMMW-

600 mm Products

NGF-M MXV-M VLM-M

Splitter Ratio** A B C E F H J K 90/10 95/05 50/50 80/20 75/25 70/30 60/40 99/01

Input Connector Type Singlemode 2U FC ultra polish 2A FC angled polish 4U ST ultra polish 7U SC ultra polish 7A SC angled polish 8A E-2000 angled polish LA LX.5 angled polish LU LX.5 ultra polish KU LC ultra polish 00 Bare fiber

OR
Multimode** 2M FC 62.5/125 2N FC 50/125 5F ST 50/125 5U ST 62.5/125 9A SC 50/125 9B SC 62.5/125 LM LX.5 62.5/125 LN LX.5 50/125 PM LC 62.5/125 00 Bare fiber

100571

Multimode** 2M FC 62.5/125 OR 2N FC 50/125 5F ST 50/125 5U ST 62.5/125 9A SC 50/125 9B SC 62.5/125 LM LX.5 62.5/125 LN LX.5 50/125 PM LC 62.5/125 00 Bare fiber

10/03

*MiniVAMs are not available with E-2000 connectors/adapters **VAMs with multimode connectors/adapters can only be configured with 90/10 or uniform split (50/50) ratios. See page 58 for configuration illustrations. Please contact ADC for specifications and available split ratios.

Multimode couplers designed to be used with LED sources only. If you are using a different source, please contact the ADC Technical Assistance Center for the appropriate solution.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

57

Value-Added Module System


Splitter Modules
Adapter to attach patch cord to equipment
REAR FRONT OUT

Connectorized pigtail (3 mm jacketed) to equipment or to port on frame

IN

Adapter to attach patch cord or pigtail to OSP port

Input Front, Output Front


REAR FRONT

Input Rear, Output Front


REAR FRONT

SPLITTER COMPONENTS

IN

OUT 1xN OUTPUT OUTPUT INPUT

IN

OUT 1xN OUTPUT OUTPUT

600 mm Products

Stub fiber input spliced to equipment or OSP fibers (2 mm jacketed)

Connectorized pigtail to OSP port on the fiber frame

INPUT

WDM Modules
REAR Adapter port Connectorized pigtail (3 mm jacketed) Bare pigtail (2 mm jacketed) FRONT

2
Adapter port

Mux Front, Demux Front


REAR FRONT

Mux Rear, Demux Front


REAR FRONT

WDM

Connectorized pigtail
WDM Demux Demux Mux WDM Demux Demux

Mux

100571

Monitor Modules
B Customer Premises Monitor Module
1x2 SPLITTER B
XX% XX%

Dual Monitor Cross-Connect

Dual Monitor Cross-Connect


Mon Tx Mon Rx

Dual Monitor Cross-Connect with Variable Attenuator


VAR ATTN

10/03

CUST MON Tx SRC MON Rx


10% SPLITTER

1x2

Tx Tx MON Rx MON
1x2 SPLITTER

1x2 SPLITTER A

XX% XX%

SRC Rx CUST Rx CUST Tx SRC Tx

90%

Tx Rx Rx

1x2

Tx Mon Rx Mon

10% 90%

Tx Rx

1x2

Tx SRC Rx SRC

Tx Rx

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

58

Value-Added Module System


Bulkhead Plates and Blanks

ADC ADC

VAM-BLNK

VAM-6PBX

600 mm Products

Ordering Information
Description Blank plate Six position bulkhead plates loaded with: Singlemode FC adapters FC angled polish adapters ST adapters SC adapters SC angled polish adapters (3) duplex SC adapters E-2000 angled polish APC adapters Multimode ST adapters SC adapters (3) duplex SC adapters Catalog Number* VAM-BLNK

VAM-6PB2 VAM-A6PB2 VAM-6PB4 VAM-6PB7 VAM-A6PB5 VAM-D6PB7 VAM-A6PB8

VAM-6PB5 VAM-6PB9 VAM-D6PB9

* These products are available in black; for this option, simply add -BK to the end of the catalog number. Please contact the Technical Assistance Center with any questions.

100571

Terminators
Terminator plugs should be ordered for each unterminated leg on ultra polish adapter ports. For configurations with pigtails an adapter is also required.
Ordering Information
Description FC connector ST connector SC connector Catalog Number FOC-TERMFC-P FOC-TERMST-P FOC-TERMSC-P

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

59

Value-Added Module System


Singlemode Wideband Optical Splitter Specifications
Other splitter configurations are available. Please call ADC Technical Assistance Center.
Splitter Number 2000 2100 2200 2300 2350 2400 2500 2600 2700 2800 2900 2950 2030 3900 4900 5300 6000 7000 8000 9000 A110 B111 C112 D113 E114 F115 G116 M132 Splitter Type 1x2 1x2 1x2 1x2 1x2 1x2 1x2 1x2 1x2 1x2 1x2 1x2 2x2 1x3 1x4 1x5 1x6 1x7 1x8 1x9 1x10 1x11 1x12 1x13 1x14 1x15 1x16 1x32 Splitter Ratio 50/50 55/45 60/40 65/35 66.6./33.3 70/30 75/25 80/20 85/15 90/10 95/5 99/1 50/50 33/33/33 25/25/25/25 20/20/20/20/20 16.6/16.6/ . . . 16.6 14.3/14.3/ . . . /14.3 12.5/12.5/ . . .12.5 11.1/11.1/ . . . /11.1 10/10/10 . . . /10 9.1/9.1/ . . . /9.1 8.3/8.3/ . . . /8.3 7.7/7.7/ . . . /7.7 7.14/7.14/ . . . /7.14 6.66/6.66/ . . . /6.66 6.25/6.25/ . . . 6.25 3.13/3.13/ . . . 3.13 Maximum Insertion Loss* 3.7/3.7 3.2/4.1 2.7/4.7 2.3/5.3 2.2/5.5 2.0/6.0 1.6/6.8 1.3/7.8 1.0/9.2 .8/11.2 .5/14.4 0.3/22.5 3.7/3.7 5.9/5.9/5.9 7.4/7.4/7.4/7.4 8.6/8.6/8.6/8.6/8.6 9.8/9.8/9.8/ . . ./9.8 10.6/10.6/ . . . /10.6 11.3/11.3/ . . . /11.3 11.5/11.5/ . . . /11.5 12.1/12.1/ . . . /12.1 13.1/13.1/ . . . /13.1 13.3/13.3/ . . . /13.3 13.8/13.8/ . . . /13.8 13.8/13.8/ . . . /13.8 14.5/14.5/ . . . /14.5 14.9/14.9/ . . . 14.9 18.5/18.5/ . . . 18/5 Typical Insertion Loss* 3.1/3.1 2.7/3.6 2.3/4.1 2.0/4.7 1.9/5.0 1.7/5.4 1.4/6.2 1.1/7.1 .8/8.4 .6/10.2 .4/13.2 NA/NA 3.1/3.1 5.0/5.0/5.0 6.2/6.2/6.2/6.2 7.3/7.3/7.3/7.3/7.3 8.1/8.1/8.1 . . . /8.1 8.9/8.9/ . . . /8.9 9.5/9.5/ . . ./9.5 9.9/9.9/ . . . /9.9 10.4/10.4/ . . . /10.4 10.9/10.9/ . . . /10.9 11.3/11.3/ . . . /11.3 11.6/11.6/ . . . /11.6 11.8/11.8/ . . . /11.8 12.4/12.4/ . . . /12.4 12.6/12.6/ . . . 12.6 15.8/15.8/ . . . 15.8

100571

600 mm Products
10/03

* Does not include connector losses. See table on the following page or contact the ADC Technical Assistance Center.

Maximum Insertion Loss Maximum insertion loss is the upper limit of insertion loss for the coupler and applies over the entire wavelength range specified in the bandpass. Typical Insertion Loss Typical insertion loss is the expected insertion loss value for the coupler measured at the specified center wavelength (i.e. 1310 nm and/or 1550 nm).

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

60

Value-Added Module System


Singlemode Optical Splitter Specifications
MATERIAL Fiber: Jacket: Housing: OPTICAL Bandpass Wavelength 1: Wavelength 2: Directivity: Reflectance: Polarization Stability: MECHANICAL Cable Retention: Flex: Twist: Vibration: Impact: Flammability: ENVIRONMENTAL Humidity: Thermal Aging: Temperature Cycling: Corning SMF-28 0.900 mm hytrel tube Stainless steel tube

600 mm Products

1260/1360 nm 1430/1580 nm 55 dB minimum < -55 dB .5 dB maximum .45 kg (1.0 lb.) maximum for .25 mm and .900 mm fiber, 1 kg (2.2 lbs.) maximum for cabled fiber assemblies 300 cycles; .45 kg (1.0 lb.) maximum load (fiber cable only) 100 cycles; .45 kg (1.0 lb.) maximum load (fiber cable only) 10-55 Hz per FOTP II condition I 8 drops from 1.5 meters All materials used in fabrication of coupler housing meet UL 94, Level V-I requirements 336 hours, 60C at 95% relative humidity 336 hours, 85C 336 hours, -40C to 85C

Singlemode Optical Connector Specifications


100571
INSERTION LOSS (dB) Ultra Polish PC Connectors Angled Polish Connectors 0.3 dB maximum 0.1 dB typical 0.5 dB maximum 0.1 dB typical RETURN LOSS (dB) 57 dB minimum 65 dB minimum

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

61

Value-Added Module System


Singlemode WDM Specifications
MATERIAL Fiber: Jacket: OPTICAL Uniformity: Polarization Stability: Bandpass: Insertion Loss: Reflectance: Isolation Near End: Far End: MECHANICAL Cable Retention: Flex: Twist: Vibration: Impact: Flammability: 45 kg (1.0 lb.) maximum for .250 mm and .900 mm fiber; 1.0 kg (2.2 lbs.) maximum for cabled fiber assemblies 10-55 Hz per FOTP II condition I 100 cycles; 8 drops from 1.5 meters All materials used in fabrication of the coupler housing meet UL 94, Level V-I requirements Corning SMF-28 0.900 mm

600 mm Products

1.0 Log2N (where N = number of channels) 0.5 dB maximum (see table below) (see table below) < -55 dB 55 dB (see table below)

ENVIRONMENTAL Humidity Resistance: Thermal Aging: Temperature Cycling:

336 hours, 60C at 95% relative humidity 336 hours, 85C 336 hours, -40C to 85C

1310/1550 nm

100571

PASSBAND (nm) 1310 20 nm and 1550 20 nm 1310 20 nm and 1550 20 nm 1310 20 nm and 1550 20 nm 1310 20 nm and 1550 20 nm

MAXIMUM INSERTION LOSS* (dB) 0.3 0.7 1.0 0.3

MINIMUM ISOLATION (dB) 15 30 45 15

Multiplexer/Demultiplexer: High Isolation Demultiplexer: Very High Isolation Demultiplexer: Wavelength Filters:

10/03

1533/1557 nm

PASSBAND (nm) 1533 3 and 1557 3 nm

MAXIMUM INSERTION LOSS* (dB) 0.9

MINIMUM ISOLATION (dB) N/A

Unidirectional Multiplexer: High Isolation Undirectional Multiplexer or Bidirectional Multiplexer/Demultiplexer: Very High Isolation Undirectional Multiplexer or Bidirectional Multiplexer/Demultiplexer: Filter Passing 1533 nm: Filter Passing 1557 nm:

1533 3 and 1557 3 nm

1.8

20

1533 3 and 1557 3 nm 1533 3 nm 1557 3 nm

2.1 0.9 0.9

35 13 13

* Maximum Insertion Loss does not include connector loss.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

62

Fiber Management Tray


Introduction
ADCs fiber management trays provide a flexible, economical approach to handling your networks most vital elements by offering four different designs. Termination, termination/splicing, termination/storage, and slack storage designs are offered with ADCs modular, all-front access trays.

Features

All-Front Access Design

600 mm Products

Sliding radius limiters provide ultimate fiber management by addressing one of the most critical elements of fiber cable management: bend radius protection. As fibers leave the tray, a specially designed bell-shaped exit point provides maximum edge protection. By controlling the movement of fibers within the tray, error-proof slack loop management is maintained, ensuring 30 mm bend radius protection within the tray. This is crucial in ensuring no fiber breaks, which cause service failures and increase network operations costs. Sliding adapter packs allow easy access for connecting jumpers and cleaning connectors, ensuring that any fiber can be installed or removed without inducing a macrobend on an adjacent fiber. That can mean the difference between a network reconfiguration time of 20 minutes per fiber and one of over 90 minutes per fiber. These trays are lockable, further ensuring the integrity of the fibers by greatly reducing the chance for accidents. Modular Design The value of a single interface for performing multiple tasks in your network cannot be denied. By employing a one-rack-unit modular tray, network technicians have ready access to terminating, splicing, and storing fiber. This one-stop management approach means time saved and value added.

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

63

Fiber Management Tray


1 Rack Unit Termination Only
The termination-only fiber management tray provides termination for 24 or 32 fibers in an all-front-access design. This tray mounts in 19-inch, 23-inch, or ETSI racks. Sliding radius limiters provide cable management for incoming and outgoing fibers.

600 mm Products

24-Termination Only

32-Termination Only

Catalog Number FMT-D __ __ 0 __ 0 __ 0 __ - __ __ __ __

Drawer Configuration RT Termination only Connector/Adapter Style Multimode 5 ST 9 SC Singlemode 1 FC hybrid (FC connector on front; SC connector on back of bulkhead) 2 FC ultra polish 3 ST hybrid (ST connector on front; SC connector on back of bulkhead) 4 ST ultra polish 7 SC ultra polish F FC angled polish J SC angled polish K E-2000 angled polish L FC with zirconia adapter M MTRJ feedthrough adapter N SC with zirconia adapter P ST with zirconia adapter
1

Faceplate Color P Putty Number of Ports 24 32 Mounting Style1 A 19"/5" recess C 19"/2.2" recess E 19"/40 mm recess2 F ETSI/40 mm recess2 Lock Type 0 No lock 1 Lock, key type 1 2 Lock, key type 2 Adapters Loaded A Adapters loaded 0 No adapters
All 19" mounting brackets are reversible and can mount in EIA or WECO racks. 2 40 mm recess FMTs are equipped with a special trumpet sliding radius limiter. Other mounting styles cannot be used in 40 mm recess applications.

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

64

Fiber Management Tray


The termination and splice tray terminates and splices 12, 16, or 24 fibers in an all-front-access design. This tray mounts in 19-inch, 23-inch, or ETSI racks. Sliding radius limiters provide cable management for incoming and outgoing fibers. Panels loaded with pigtails come with color-coded 900 micron pigtails.

1 Rack Unit Termination and Splice

24-Termination/Splice (right splice entry)

600 mm Products

12-Termination/Splice (right splice entry)

24-Termination/Splice (right splice entry)

24-Termination/Splice (left splice entry)

Catalog Number FMT - D __ __ 0 __ 0 __ __ __ - __ __ __ __ Configuration TL Term splice with splice tray (left splice entry) TR Term splice with splice tray (right splice entry) Connector/Adapter Style Multimode 5 ST 9 SC Singlemode 1 FC hybrid (FC connector on front; SC connector on back of bulkhead) 2 FC ultra polish 3 ST hybrid (ST connector on front; SC connector on back of bulkhead) 4 ST ultra polish 7 SC ultra polish F FC angled polish J SC angled polish K E-2000 angled polish L FC with zirconia adapter N SC with zirconia adapter P ST with zirconia adapter Cable or Adapter Type A Adapters only 0 No adapters C Multimode pigtails (50/125) K Multimode pigtails (62.5/125) U Singlemode Maxi-Strip pigtails R Singlemode ribbon pigtails Faceplate Color P Putty Number of Ports 12 16 24 Mounting Style1 A 19"/5" recess C 19"/2.2" recess E 19"/40 mm recess2 F ETSI/40 mm recess2 Lock 0 1 2 Type No lock Lock, key type 1 Lock, key type 2

10/03

100571

Chip Style (mini splice tray) 0 N/A 2 Heat shrink 3 Mechanical


1 All 19" mounting brackets are reversible and can mount in EIA and WECO racks.

40 mm recess FMTs are equipped with a special trumpet sliding radius limiter. Other mounting styles cannot be used in 40 mm recess applications.
2

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

65

Fiber Management Tray

1 Rack Unit Termination and Storage


The termination and storage tray terminates and stores 12, 16, or 24 fibers in an all-front-access design. This tray mounts in 19-inch, 23-inch, or ETSI racks, while sliding radius limiters provide cable management for incoming and outgoing fibers.

12-Termination/Storage (universal storage)

600 mm Products

16-Termination/Storage (universal storage)

24-Termination/Storage (right storage)

24-Termination/Storage (left storage)

Catalog Number FMT-D __ __ 0 __ 0 __ 0 __ - __ __ __ __ Configuration SL Termination/storage (left storage) SR Termination/storage (right storage) ST Termination/storage (universal storage) Connector/Adapter Style Multimode 5 ST 9 SC Singlemode 1 FC hybrid (FC connector on front; SC connector on back of bulkhead) 2 FC ultra polish 3 ST hybrid (ST connector on front; SC connector on back of bulkhead) 4 ST ultra polish 7 SC ultra polish F FC angled polish J SC angled polish K E-2000 angled polish L FC with zirconia adapter M MTRJ feedthrough adapters N SC with zirconia adapter P ST with zirconia adapter
All 19" mounting brackets are reversible and can mount in EIA and WECO racks.
1 2 40 mm recess FMTs are equipped with a special trumpet sliding radius limiter. Other mounting styles cannot be used in 40 mm recess applications.

Faceplate Color P Putty Number of Ports 12 Available with ST configuration only 16 Available with ST configuration only 24 Available with SR and SL configurations only Mounting Style1 A 19"/5" recess C 19"/2.2" recess E 19"/40 mm recess2 F ETSI/40 mm recess2 Lock 0 1 2 Type No lock Lock, key type 1 Lock, key type 2

10/03

100571

Adapters Loaded A Adapters loaded 0 No adapters

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

66

Fiber Management Tray


1 Rack Unit Slack Storage Panels
The slack storage tray offer bulk storage for up to 60 fibers, and discrete slack storage for up to 16 fibers. This all-front-access tray mounts in 19-inch, 23-inch, or ETSI racks. Sliding radius limiters provide cable management for incoming and outgoing fibers.

Bulk/Storage Drawer

600 mm Products

Discrete/Storage Drawer

Capacity Slack storage type Bulk 32 cables, 3 mm cable 2.5 m each 16 cables 1.7 m each 2 mm cable 48 cables, 2.5 m each 16 cables, 2 m each 1.7 mm cable 60 cables, 4 m each 16 cables 2.5 m each

100571

Discrete

Catalog Number FMT - D __ __ 0 0 0 00 __ - __ 00 __ Drawer Configuration BS Bulk storage DS Discrete storage Lock 0 1 2 Type No lock Lock, key type 1 Lock, key type 2 Faceplate Color P Putty Mounting Style1 A 19"/5" recess C 19"/2.2" recess E 19"/40 mm recess2 F ETSI/40 mm recess2
1 All 19" mounting brackets are reversible and can mount in EIA and WECO racks. 2 40 mm recess FMTs are equipped with a special trumpet sliding radius limiter. Other mounting styles cannot be used in 40 mm recess applications.

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

67

Fiber Management Tray


1 Rack Unit Splicing Only

Splicing Only

Splicing Only

600 mm Products

Catalog Number FMT - DAS0000 __ __ - __ __ __ __ Splice Type 0 None 2 Heat shrink 3 Mechanical Lock 0 1 2 Type No lock Lock, key type 1 Lock, key type 2 Faceplate Color P Putty Number of Splices/Capacity 12 1 tray 24 2 trays Mounting Style1 A 19"/5" recess C 19"/2.2" mm recess E 19"/40 mm recess2 F ETSI/40 mm recess2
1 All 19" mounting brackets are reversible and can mount in EIA and WECO racks.

100571

10/03

40 mm recess FMTs are equipped with a special trumpet sliding radius limiter. Other mounting styles cannot be used in 40 mm recess applications.
2

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

68

Fiber Management Tray

1 Rack Unit Termination and Splice Fixed Bulkhead


This configuration features fixed bulkhead style adapter plates and accommodates singlemode SC (ultra polish and angled), E-2000, LC and LX.5, as well as multimode SC, LC, and LX.5 adapters. The tray can be ordered with adapters only, or with pigtails.

600 mm Products

Termination/Splice Fixed Bulkhead (right splice entry)

Termination/Splice Fixed Bulkhead (right splice entry)

Catalog Number FMT-D __ __ 0 __ 0 __ __ __ - __ __ __ __ Configuration TW Termination/splice with bulkhead plate (right splice entry) TX Termination/splice with bulkhead plate (left splice entry) Connector/Adapter Style Multimode 9 SC Y LX.5 6 LC Singlemode 7 SC ultra polish J SC angled polish K E-2000 angled polish 8 LC X LX.5 Adapters Loaded1 A Adapters only 0 No adapters OR Pigtail Type2 U Singlemode Maxi-Strip pigtails K Multimode pigtails (62.5/125) C Multimode pigtails (50/125)
When ordering FMTs with adapters only, enter number of adapters (00 to 24).
1 2 3

Faceplate Color P Putty Number of Ports with Adapters1 01...24 Adapters only OR Number of Pigtails2 08 8 pigtails 12 12 pigtails 16 16 pigtails 24 24 pigtails Mounting Style3 A 19"/5" recess C 19"/2.2" recess E 19"/40 mm recess4 F ETSI/40 mm recess4 Lock 0 1 2 Type No lock Lock, key type 1 Lock, key type 2

10/03

100571

Splice Type 0 None 2 Heat shrink 3 Mechanical

FMTs can be ordered with 8, 12, 16 and 24 pigtails only.

All 19" mounting brackets are reversible and can mount in EIA and WECO racks.
4 40 mm recess FMTs are equipped with a special trumpet sliding radius limiter. Other mounting styles cannot be used in 40 mm recess applications.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

69

Fiber Management Tray

1 Rack Unit Termination and Storage Fixed Bulkhead


This configuration features fixed bulkhead style adapter plates and accommodates singlemode SC (ultra polish and angled), E-2000, LC and LX.5, as well as multimode SC, LC, and LX.5 adapters. When ordered with 24 LC or LX.5 adapters, this FMT supports 48 fibers.

600 mm Products

Termination/Storage Fixed Bulkhead (right storage)

Termination/Storage Fixed Bulkhead (right storage)

Catalog Number FMT-D __ __ 0 __ 0 __ 0 __ - __ __ __ __ Configuration SG Termination/storage with bulkhead plate (right storage entry) SF Termination/storage with bulkhead plate (left storage entry) Connector/Adapter Style Multimode 9 SC Y LX.5 6 LC Singlemode 7 SC ultra polish J SC angled polish K E-2000 angled polish 8 LC X LX.5 Adapters Loaded A Adapters only 0 No adapters
1 All 19" mounting brackets are reversible and can mount in EIA and WECO racks.

Faceplate Color P Putty Number of Ports with Adapters 01...24 Mounting Style1 A 19"/5" recess C 19"/2.2" recess E 19"/40 mm recess2 F ETSI/40 mm recess2 Lock 0 1 2 Type No lock Lock, key type 1 Lock, key type 2

10/03

100571

40 mm recess FMTs are equipped with a special trumpet sliding radius limiter. Other mounting styles cannot be used in 40 mm recess applications.
2

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

70

Fiber Management Tray


1 Rack Unit Accessories Sliding Adapter Packs
Ordering Information
Description Multimode ST SC Singlemode FC hybrid (FC connector on front; SC connector on back of bulkhead) FC ultra polish ST hybrid (ST connector on front; SC connector on back of bulkhead) ST ultra polish SC ultra polish FC angled polish SC angled polish E-2000 angled polish FC with zirconia adapter SC with zirconia adapter ST with zirconia adapter Catalog Number FMT-2SAP05 FMT-2SAP09 FMT-2SAP01 FMT-2SAP02 FMT-2SAP03 FMT-2SAP04 FMT-2SAP07 FMT-2SAP0F FMT-2SAP0J FMT-2SAP0K FMT-2SAP0L FMT-2SAP0N FMT-2SAP0P

600 mm Products

Accessories
Ordering Information
Description Wall mount kit Catalog Number FMT-ACCWLMT01 FMT-ACCCLMP01 FMT-ACCCLMP02 FMT-ACC01B FMT-ACC01P

100571

Cable clamp kits .25" offset from frame 1.25" offset from frame Vertical cable guides Black Putty
Cable

Vertical Cable Guide

10/03

1.0" (2.54 cm) Wall

Cable

FMT-ACCCLMP02 1.25" Offset from Rack Rack

19.5" (49.53 cm)

FMT Panel Shown for Reference, Not Included in Kit

FMT-ACCCLMP01 0.25" Offset from Rack

Cable Clamp Kit

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

71

Fiber Management Tray


1 Rack Unit Specifications
PHYSICAL Approximate Weight: Configuration Options and Capacity: 8 to 10 lbs (3.7 to 4.5 kg) Termination only (24 or 32 fibers) Termination/storage (12, 16, or 24 terminations) Bulk Storage 3 mm outer diameter cable: 32 cables, length 2.5 m each 2 mm outer diameter cable: 48 cables, length 2.5 m each 1.7 mm outer diameter cable: 60 cables, length 4 m each Discrete storage 3 mm outer diameter cable: 16 cables, length 1.7 m each 2 mm outer diameter cable: 16 cables, length 2 m each 1.7 mm outer diameter cable: 16 cables, length 2.5 m each Termination/splicing (12, 16, or 24 splices)

600 mm Products

17.26" (43.84 cm)

11.01" (27.97 cm)

A B
1.7" (4.32 cm) Front View Shown without Sliding Radius Limiters

Universal Mounting Bracket, EIA or WECO rack mount

100571

Ordering Code C

Configuration 19" EIA (2.2" recess) 19" EIA (40 mm recess) 19" EIA (5" recess) ETSI (40 mm recess)

A 18.32" (46.5 cm) 18.32" (46.5 cm) 18.32" (46.5 cm)

B 1.25" (3.2 cm) 1.25" (3.2 cm) 1.25" (3.2 cm)

C 2.25" (5.7 cm) 1.54" (3.9 cm) 5.0" (12.7 cm) 1.54" (3.9 cm)

10/03

E A F

20.28" (51.5 cm) 0.98" (2.5 cm)

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

72

Fiber Management Tray

2 Rack Unit Termination with Adapters Only


The termination-only fiber management tray provides termination for 72 fibers in an all-front-access design. This tray mounts in 19-inch, or ETSI racks. Sliding radius limiters provide cable management for incoming and outgoing fibers.

600 mm Products

Sliding Adapter Pack Shown in Access Position 72-Termination with Adapters Only

Catalog Number FMT-GRT0 __ 0 __ 0 __ - A72 __

10/03

100571

Connector/Adapter Style Multimode 9 SC Y LX.5 6 LC Singlemode 2 FC ultra polish 7 SC ultra polish F FC angled polish J SC angled polish L FC with zirconia adapter N SC with zirconia adapter 8 LC ultra polish X LX.5 angled polish

Faceplate Color P Putty Lock Type 0 No lock 1 Lock, key type 1 2 Lock, key type 2 Adapters Loaded A Adapters loaded 0 No adapters

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

73

Fiber Management Tray

2 Rack Unit Termination with IFC or Multifiber Cable


The termination-only fiber management tray provides termination for 72 fibers and can be ordered preterminated with IFC or multifiber cable. This tray mounts in 19-inch, or ETSI racks. Sliding radius limiters provide cable management for incoming and outgoing fibers.

600 mm Products

72-Termination with IFC or Multifiber Cable

Catalog Number FMT-GN7 __ __ __ __ __ __ - A 7 2 __

Cable Type Multimode C IFC stranded (62.5/125) Y IFC stranded (50/125) Singlemode A IFC stranded M IFC ribbon H Indoor/outdoor Connector/Adapter Style Multimode 9 SC Y LX.5 6 LC Singlemode 2 FC ultra polish 7 SC ultra polish F FC angled polish J SC angled polish L FC with zirconia adapter N SC with zirconia adapter 8 LC ultra polish X LX.5 angled polish

Faceplate Color P Putty Lock Type 0 No lock 1 Lock, key type 1 2 Lock, key type 2 Length (in meters)

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

74

Fiber Management Tray


The termination and splice tray terminates and splices 48 fibers in an all-front-access design. This tray mounts in 19-inch, or ETSI racks. Sliding radius limiters provide cable management for incoming and outgoing fibers. Panels loaded with pigtails come with color-coded 900 micron pigtails.

2 Rack Unit Termination and Splice

48-Termination/Splice

600 mm Products

Catalog Number FMT-GTL 0 __ 0 __ __ __ - A48 __ Connector/Adapter Style Multimode 9 SC Y LX.5 6 LC Singlemode 2 FC ultra polish 7 SC ultra polish F FC angled polish J SC angled polish L FC with zirconia adapter N SC with zirconia adapter 8 LC ultra polish X LX.5 angled polish Cable or Adapter Type A Adapters only 0 No adapters C Multimode pigtails (50/125) K Multimode pigtails (62.5/125) U Singlemode Maxi-Strip pigtails Faceplate Color P Putty Lock 0 1 2 Type No lock Lock, key type 1 Lock, key type 2

Chip Style (mini splice tray) 0 None 2 Heat shrink 3 Mechanical

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

75

Fiber Management Tray


2 Rack Unit Accessories Sliding Adapter Packs
Ordering Information
Description Multimode SC LC LX.5 Catalog Number FMT-6SAP09 FMT-6SAP06 FMT-6SAP0Y FMT-6SAP02 FMT-6SAP07 FMT-6SAP0F FMT-6SAP0J FMT-6SAP0L FMT-6SAP0N FMT-6SAP08 FMT-6SAP0X

600 mm Products

Singlemode FC ultra polish SC ultra polish FC angled polish SC angled polish FC with zirconia adapter SC with zirconia adapter LC ultra polish LX.5 angled polish

Accessories
Ordering Information
Description Cable clamp kits .25" offset from frame 1.25" offset from frame Vertical cable guides Black Putty Catalog Number FMT-ACCCLMP01 FMT-ACCCLMP02 FMT-ACC21B FMT-ACC21P
Cable

100571

Cable

10/03

FMT-ACCCLMP02 1.25" Offset from Rack Rac

FMT-ACCCLMP01 0.25" Offset from Rack

Vertical Cable Guide Cable Clamp Kit

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

76

Fiber Management Tray

2 Rack Unit Micro Value-Added Module System


The 2RU FMT Value-Added Module (VAM) chassis houses up to twelve MicroVAMs. These MicroVAMs are used for testing and monitoring optical signals; technicians can access both directions of the signal without disrupting service.

600 mm Products

MicroVAM Shown in Access Position FMT-G Series with MicroVAM

Ordering Information
Description 2 RU Fiber Management Tray (FMT-G Series) accommodates up to 12 MicroVAMs for monitoring optical signals Catalog Number FMT-GVM00000-A72P

Ordering Information for Micro Value-Added Modules follows on the next page.

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

77

Fiber Management Tray

2 Rack Unit Micro Value-Added Module System Monitor Module Ordering Information
Catalog Number FMT-M __ __ __ 1 __ __ 0 0 0

600 mm Products

Input Connector/Adapter Singlemode 2U FC ultra polish 2A FC angled polish 7U SC ultra polish 7A SC angled polish LA LX.5 angled polish KU LC ultra polish or Multimode** 9A SC 50/125 9B SC 62.5/125 LM LX.5 PM LC Output Connector/Adapter Singlemode 2U FC ultra polish 2A FC angled polish 7U SC ultra polish 7A SC angled polish LA LX.5 angled polish KU LC ultra polish Multimode** 9A SC 50/125 9B SC 62.5/125 LM LX.5 PM LC or

Module Style B Cross-connect customer premises J Dual monitor S Splitter module Split A B C H J K L Ratio 90/10 95/05 50/50 70/30 60/40 99/01 98/02

100571

Monitor Connector Type Singlemode 2U FC ultra polish 2A FC angled polish 7U SC ultra polish 7A SC angled polish LA LX.5 angled polish KU LC ultra polish or Multimode** 9A SC 50/125 9B SC 62.5/125 LM LX.5 PM LC
Contact the ADC Technical Assistance Center, for specifications and available split ratios.

10/03

Customer Premises Monitor Module


1x2 SPLITTER B
XX% XX%

Dual Monitor Cross-Connect


Mon Tx Mon Rx

Splitter Module
1x2

RxM TxM

1x2

A1 A2

1x2 SPLITTER A

XX% XX%

RxN TxN CUST Tx SRC Tx


1x2

Tx Rx
1x2

A B1 B2 B

Tx SRC Rx SRC

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

78

Fiber Optic Patch Cords


Singlemode
Catalog Number __ __ - __ - S - __ M Cable Option FPC Connector on both ends (patch cord) FPT Connector on one end (pigtail) Cable Type Leave 3 mm single Blank M 2 mm single F 1.7 mm single 9 900 micron Z 3 mm dual zip 2 2 mm dual zip T 1.7 mm dual zip
For hybrid patch cords, enter both connector types in this field and separate them with a slash mark; remove S from the ultra polish connector options (see second ordering example). 2 One connector per end; requires dual zip cable 3 Requires 900 micron, 1.7 mm or 2 mm cable 4 Requires 1.7 mm or 2 mm dual zip cable
1

Length
X Length in meters

600 mm Products

Connector Type1 SPSC SC ultra polish APSC SC angled polish SDSC SC duplex2 SPFC FC ultra polish APFC FC angled polish SPST ST ultra polish AE2 E-2000 angled polish SPLX LX.5 ultra polish3 ALX5 LX.5 angled polish3 SDLX LX.5 ultra polish duplex4 ADLX LX.5 angled polish duplex4 SPLC LC ultra polish SDLC LC ultra polish duplex2

Ordering Example FPC2-SPFC-10M: Patch cord with ultra polish FC connectors on both ends, 2 mm dual zip cable, 10 meters in length with standard breakout length of 12" on both ends. FPC-SPST/PSC-S-10M: Patch cord with ST ultra polish connector on one end and SC ultra polish connector on the other end, 10 meters in length.

100571

Multimode
Cable Option FPC Connector on both ends (patch cord) FPT Connector on one end (pigtail) Cable Type 3 mm single M 2 mm single F 1.7 mm single 9 900 micron Z 3 mm dual zip 2 2 mm dual zip T 1.7 mm dual zip

Catalog Number __ __ - __ - __ - __ M Length


X Length in meters

10/03

Fiber Size A B 50/125 62.5/125

For hybrid patch cords, enter both connector types in this field and separate them with a slash mark 2 One connector per end; requires dual zip cable 3 Requires 900 micron, 1.7 mm or 2 mm cable 4 Requires 1.7 mm or 2 mm dual zip cable
1

Connector Type1 MSC SC ultra polish MDSC SC duplex2 MFC FC ultra polish MST ST ultra polish MLX5 LX.5 ultra polish3 MDLX LX.5 duplex4 MLC LC ultra polish MDLC LC duplex2

Ordering Example FPC-MST/MSC-B-7M: Patch cord with ST ultra polish connector on one end and SC ultra polish connector on the other end, 62.5/125 fiber size, 7 meters in length.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

79

Fiber Optic Patch Cords

Multifiber Patch Cords (4 to 32 fibers)


Cable Jacket, PVC 0.89 mm thick Central Strength Aramid Yarn Member 1.7 mm Fiber subunit Ripcord Ripcord PVC Jacket 0.64 mm thick Cable Jacket, PVC 1.65 mm thick Aramid Yarn Central Strength Member 1.7 mm Fiber subunit Ripcord Ripcord

Buffered Fiber 900 micron

Standard Wall (4-fiber shown)

Soft Wall (12-fiber shown)

(12 fib

Thick Wall (4-fiber shown)

600 mm Products

Standard wall: Available with 4, 6, 12 or 32 tight buffered 1.7 mm fibers enclosed in a standard wall outer jacket. Each 1.7 mm fiber is coded for easy identification of individual fibers. Central strength member, aramid yarn; PVC jacket thickness 0.89 mm. Soft wall: Available with 6, 8 or 12 tight buffered 900 micron fibers with a thin outer jacket. No central strength member or aramid yarn; PVC jacket thickness 0.64 mm. Thick wall: Available with 4 or 24 tight buffered 1.7 mm fibers. Each 1.7 mm fiber is coded for easy identification of individual fibers. Central strength member, aramid yarn; PVC jacket thickness 1.65 mm.

Singlemode
Connector Type (1st and 2nd end) 0 Stub 7 SC ultra polish 4 ST ultra polish 2 FC ultra polish E SC angled polish D FC angled polish J E-2000 angled polish* N LX.5 ultra polish L LX.5 angled polish K LC ultra polish
* E-2000 is not available with 1.7 mm subunits.

Catalog Number FPM-0 __ / __ - __ __ __ __ M- __ __ / __ __ Length


X Length in meters

Breakout Length
X Length in inches Leave blank if both ends 12"

10/03

Cable A D W E P L F M AD BD

Type 4-fiber thick wall with 1.7 mm subunits 4-fiber standard wall with 1.7 mm subunits 4-fiber soft wall 6-fiber standard wall with 1.7 mm subunits 6-fiber soft wall 8-fiber soft wall 12-fiber standard wall with 1.7 mm subunits 12-fiber soft wall 24-fiber thick wall with 1.7 mm subunits 32-fiber thick wall with 1.7 mm subunits

100571

Multimode
Connector Type (1st and 2nd end) 0 9 5 A X P Stub SC ultra polish ST ultra polish FC ultra polish LX.5 ultra polish LC ultra polish

Catalog Number MFPM- __ / __ - __ __ __ __ M- __ __ / __ __ Length


X Length in meters

Breakout Length
X Length in inches Leave blank if both ends 12"

Cable Type WB 4-fiber soft wall, 62.5/125 PB 6-fiber soft wall, 62.5/125 NB 12-fiber soft wall, 62.5/125

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

80

Fiber Optic Patch Cords


TracerLight Connector Identification System
ADCs innovative TracerLight Connector Identification System offers a quick and accurate method of identifying the termination point of optical patch cords. Each end of a TracerLight patch cord features a flashing light source allowing technicians to visually trace individual patch cords from one end to the other without pulling the patch cord. The TracerLight power source is inserted into the TracerLight component on one end of the patch cord. This causes the LED on each end to begin flashing rapidly so the distant end of the patch cord can be quickly and easily identified without interruption of service.

600 mm Products

Singlemode Simplex
Catalog Number FTL- __ / __ - __ __ __ __ M Connector Style (first end) 7 SC ultra polish 4 ST ultra polish 2 FC ultra polish N LX.5 ultra polish E SC angled polish D FC angled polish L LX.5 angled polish Length (in meters) Example: 050 = 50 meters 125 = 125 meters Cable Type D Singlemode single fiber

Connector Style (second end) 7 4 2 N E D L SC ultra polish ST ultra polish FC ultra polish LX.5 ultra polish SC angled polish FC angled polish LX.5 angled polish

100571

Multimode Simplex
Catalog Number FTL- __ / __ - __ __ __ __ M

10/03

Connector Style (first end) 9 SC 5 ST A FC X LX.5 Connector Style (second end) 9 5 A X SC ST FC LX.5

Length (in meters) Example: 050 = 50 meters 125 = 125 meters Cable Type A Multimode 50/125 single fiber B Multimode 62.5/125 single fiber

Ordering information for duplex TracerLight cords follows on the next page.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

81

Fiber Optic Patch Cords


TracerLight Connector Identification System Singlemode Duplex
Catalog Number FTL- __ __ __ __ __ __ M Connector Style (first end) 7 SC ultra polish 4 ST ultra polish 2 FC ultra polish N LX.5 ultra polish E SC angled polish D FC angled polish L LX.5 angled polish Length (in meters) Example: 050 = 50 meters 125 = 125 meters Cable Type Z Singlemode dual zip fiber

600 mm Products

Connector Style (second end) 7 4 2 N E D L SC ultra polish ST ultra polish FC ultra polish LX.5 ultra polish SC angled polish FC angled polish LX.5 angled polish

Multimode Duplex
Catalog Number FTL- __ __ __ __ __ __ M Connector Style (first end) 9 SC 5 ST A FC X LX.5 Connector Style (second end) 9 5 A X SC ST FC LX.5 Length (in meters) Example: 050 = 50 meters 125 = 125 meters Cable Type E Multimode 50/125 dual zip fiber F Multimode 62.5/125 dual zip fiber

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

82

Fiber Optic Cable Assemblies


IFC Assemblies
Intrafacility fiber cable (IFC) is a multifiber cable designed for use within a building. Generally, it is constructed without metallic strength members and is designed to meet the fire resistant characteristics required in the central office. The number of fibers range from 12 to 216. Standard IFC assemblies are riser rated and meet UL-1666 OFNR. Two types of IFC are available: ribbon and stranded. Ribbon cable consists of multifibers arranged in ribbons. Each ribbon contains 12 fibers and is identified as a subunit. The fibers which comprise the ribbons are color-coded for identification. With the construction of ribbon cable, the fibers are located in the center of the cable and the outer jacket provides the strength and protection of the cable.

600 mm Products

PVC OUTER JACKET FIBERGLASS STRENGTH MEMBERS PVC INNER JACKET

DETAIL A

DETAIL B
Coating SEE DETAIL B Cladding

SEE DETAIL A

MYLAR TAPE 1 2 3 4 5 6 7 8 9 10 11 12 RIBBON AIR CORE 1 - Blue 2 - Orange 3 - Green 4 - Brown 5 - Slate 6 - White 7 - Red 10 - Violet 8 - Black 11 - Rose 9 - Yellow 12 - Aqua

Core

With stranded cable, individual 900 micron fibers make up the construction of the cable. The fibers are bundled into subunits of 6 or 12 fibers each. Each subunit is identified and the individual fibers within the subunits are color-coded. Stranded IFC diameters increase in proportion with the fiber counts.
DETAIL A

100571

6-FIBER SUBUNIT (SEE DETAIL A) MYLAR TAPE PVC CABLE JACKET

12-FIBER SUBUNIT (SEE DETAIL B) MYLAR TAPE PVC CABLE JACKET

PVC JACKET

BUFFERED FIBER
SEE DETAIL C

ARAMID YARN

RIPCORD (2) CENTRAL STRENGTH MEMBERS RIPCORD (2) CENTRAL STRENGTH MEMBERS

DETAIL B
PVC JACKET

10/03

6-Fiber Subunits (example shows 36 fibers)

12-Fiber Subunits (example shows 72 fibers)

ARAMID YARN
SEE DETAIL C

COLOR CODE CHART


PVC JACKET

BUFFERED FIBER

BUFFERED FIBER 900 MICRON ARAMID YARN

1 2 3 4 5 6 7 8 9 10 11 12

BLUE ORANGE GREEN BROWN SLATE WHITE RED BLACK YELLOW VIOLET ROSE AQUA

DETAIL C
BUFFERED FIBER
BUFFER COATING CLADDING CORE

(12-fiber shown)

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

83

Fiber Optic Cable Assemblies


IFC Assemblies Singlemode
Catalog Number IFC - __ /__ __ __ __ __ - __ Length (in meters)
Example: 020 = 50 meters 150 = 150 meters

600 mm Products

Connector Style 0 Stub 7 SC ultra polish 4 ST ultra polish 2 FC ultra polish E SC angled polish D FC angled polish J E-2000 angled polish N LX.5 ultra polish L LX.5 angled polish K LC ultra polish

Cable Type* A 12-fiber B 24-fiber C 36-fiber 2 48-fiber V 72-fiber L 96-fiber NA 12-fiber HA 24-fiber MA 36-fiber JA 48-fiber DS 72-fiber LA 96-fiber

stranded stranded stranded stranded stranded stranded ribbon ribbon ribbon ribbon ribbon ribbon

Breakout/Panel Type** LEAVE 8" FCM BLANK L FDM A 7" FCM 2A FL2, 12 exit up or down 2B FL2, 24 exit up or down 2C FL2, 48 exit up or down 2D FL2, 72 exit up 2E FL2, 96 exit up 2F FL2, 72 exit down 2G FL2, 96 exit down FTB FTB MOD 3A1 FL1-A, bottom 3A2 FL1-A, top

* For 144- or 216-fiber counts, additional fiber types and ordering information, contact your ADC representative. **ADC will customize the breakout length of the IFC to ensure proper cable management. ADC recommends using the FCM breakout length (6' = 1.8 m).

Multimode
100571
Catalog Number MIFC - __ / __ __ __ __ __ __ - __

10/03

Connector #1 Type 9 SC ultra polish 5 ST ultra polish A FC ultra polish X LX.5 ultra polish P LC ultra polish Connector #2 Type 0 Stub 9 SC ultra polish 5 ST ultra polish A FC ultra polish X LX.5 ultra polish P LC ultra polish

Length (in meters)


Example: 050 = 50 meters 125 = 125 meters

Cable Type AB 12-fiber BB 24-fiber CB 36-fiber 2B 48-fiber VB 72-fiber LB 96-fiber

stranded stranded stranded stranded stranded stranded

Fiber size 62.5 62.5 62.5 62.5 62.5 62.5

Breakout/Panel Type* LEAVE 8" FCM BLANK L FDM A 7" FCM 2A FL2, 12 exit up or down 2B FL2, 24 exit up or down 2C FL2, 48 exit up or down 2D FL2, 72 exit up 2E FL2, 96 exit up 2F FL2, 72 exit down 2G FL2, 96 exit down FTB FTB MOD 3A1 FL1-A, bottom 3A2 FL1-A, top

*ADC will customize the breakout length of the IFC to ensure proper cable management. ADC recommends using the FCM breakout length (6' = 1.8 m). Contact ADC for additional fiber types and ordering information.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

84

Fiber Optic Patch Cord Specifications


Singlemode Ultra Polish Connectors (UPC) Insertion Loss (1310 nm) Return Loss (1310 nm) Polished Endface Radius Fiber Recess Apex Offset SC 0.3 dB max. 0.1 dB typical 57 dB min. 10 mm to 25 mm 50 nm 50 micron max. ST 0.3 dB max. 0.15 dB typical 57 dB min. 10 mm to 25 mm 50 nm 50 micron max. FC 0.3 dB max. 0.1 dB typical 57 dB min. 10 mm to 25 mm 50 nm 50 micron max. LC 0.3 dB max. 55 dB min. 7 mm to 25 mm -100 to +50 nm 50 micron max.

600 mm Products

Singlemode Angled Polish Connectors (APC) Insertion Loss (1310 nm) Return Loss (1310 nm) Polished Endface Radius Fiber Recess Apex Offset Endface Angle Multimode Ultra Polish Connectors Insertion Loss (1310 nm) Return Loss (1310 nm)

SC 0.5 dB max. 0.15 dB typical 65 dB min. 5 mm to 15 mm -100 to +50 nm 50 micron 8 0.5 SC 0.7 dB max. 20 dB min.

ST 0.5 dB max. 0.2 dB typcial 55 dB min. 5 mm to 15 mm -100 to +50 nm 50 micron 8 0.5 ST 0.7 dB max. 20 dB min.

FC 0.5 dB max. 0.15 dB typcial 65 dB min. 5 mm to 15 mm -100 to +50 nm 50 micron 8 0.5 FC 0.7 dB max. 20 dB min.

LX.5 0.3 dB max. 0.1 dB typical 65 dB typical 5 mm to 12 mm -100 to +50 nm 50 micron 8 0.5 LX.5 0.4 dB max. 0.15 dB typical 25 dB min.

E-2000 0.5 dB max. 0.2 dB typical 65 dB min. 5 mm to 15 mm -100 to +50 nm 50 micron 8 0.5

Patch Cords

100571

Length 0 to 15 m +15 m

Tolerance +16 cm/-0 cm +1%/-0 cm

Multifiber
Length 0 to 15 m +15 m
L

Tolerance +16 cm/-0 cm +1%/-0 cm

10/03

IFC
Stranded Length 0 to 15 m +15 m Ribbon Length 0 to 20 m +20 m Tolerance +16 cm/-0 cm +1%/-0 cm

Tolerance +15 cm/-0 cm +90 cm/-0 cm

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

85

Fiber Optic Patch Cord Specifications


2.62 2.00 .20 .37

LX.5 (1.7 mm version shown for reference)

E-2000 (3 mm version shown for reference)

600 mm Products

2.14 .39 2.50 .22

FC (3 mm version shown for reference)

LC (1.7 mm version shown for reference)

2.25 .38

2.26

.29

100571

ST (3 mm version shown for reference)

SC (3 mm version shown for reference)

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

86

FiberGuide Fiber Management System


Introduction
The Industrys Most Comprehensive Optical Raceway System ADCs FiberGuide Fiber Cable Management System is a trough system designed to protect and route fiber optic patch cords, multifiber cable assemblies, and intrafacility fiber cable (IFC) to and from fiber splice enclosures, fiber distribution frames, and fiber optic terminal devices. The FiberGuide system is designed to ensure a 2-inch minimum bend radius is maintained throughout the system. The FiberGuide system is a complete set of products designed and manufactured to ensure total off-frame protection. Basic components include horizontal and vertical straight sections, horizontal and vertical elbows, downspouts, junctions, and numerous support hardware and flex tube kits.

600 mm Products
100571 10/03

The FiberGuide system is available in a variety of sizes: 2x2 Ideal for smaller installations or for vertical routing into individual fiber bays. It has the trough capacity to support a maximum of (400) 2 mm fiber optic patch cords. All 2x2 FiberGuide products are shipped with covers.

2x6 Designed for height-restricted environments, this robust system provides the same support and system flexibility of the traditional 4-inch-high system while saving 2 inches of overhead space. It features a maximum capacity of (1,200) 2 mm patch cords.

4x4 Features the maximum capacity to support (1,600) 2 mm patch cords. It has been engineered to allow straight sections to be self-supporting over a span of up to 6 feet (1.83 m).

4x6 Features the same benefits of the 4-inch system and a maximum trough capacity of (2,400) 2 mm patch cords.

4x12 The largest system in the FiberGuide family, this 12-inchwide trough has a maximum capacity to support nearly (5,000) 2 mm patch cords. Perfect for runs over fiber frame lineups and perimeter routes.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

87

FiberGuide Fiber Management System


New Products
ADC continues to add innovative products to the FiberGuide Fiber Management System to ensure that it remains the comprehensive solution for all optical raceway requirements and applications. These new products increase the functionality and flexibility of the FiberGuide System and are compatible with existing raceway components. Snap-Fit Junction ADC introduces the latest addition to its industry-leading FiberGuide System. The Snap-Fit Junction is the industrys first and only completely tool-less junction. No additional tools are needed for installation or removal. Quick and easy to install, the FiberGuide Snap-Fit Junction saves valuable time and money. Express Exit ADC now features three options, the low-profile Express Exit, 2-Inch Express Exit, and 4-Inch Express Exit in the innovative patented* Express Exit family to accommodate various raceway environments and applications. By simply securing an Express Exit to the sidewall of any 4x4, 4x6, or 4x12 FiberGuide straight section, jumpers can be permanently or temporarily routed to the fiber optic terminal (FOT) equipment or fiber frames below. No cutting of the FiberGuide system is required. Positioning a drop with a member of the Express Exit family greatly simplifies installation, protects the integrity of fibers already present in the raceway, and increases the overall flexibility of the raceway system. 2x6 FiberGuide System The 2x6 FiberGuide system provides another option to securely route and protect patch cords. Designed for height-restricted environments, this robust system provides the same support and system flexibility of the traditional 4x6 system while saving 2 inches of overhead space. A complete set of fittings, straight sections, junctions, and an Express Exit are available along with adapters to both the 4x4 and 4x6 systems. Raceway Reconfiguration Solutions ADC introduces two new products to facilitate easy on-site raceway reconfigurations. Available for the 4x4, 4x6, and 4x12 systems, the cut-in T and the expandable straight section provide the required flexibility to optimize raceway systems in retrofit applications without jeopardizing the integrity of existing cables.
*Other patents pending Cut-in T

600 mm Products

Snap-Fit Junction

Express Exit Family

100571

2x6 FiberGuide System

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

88

FiberGuide Fiber Management System


Patch Cord Densities
Recommended capacity takes into consideration random jumper placement into the FiberGuide system. Maximum density refers to the maximum number of fiber jumpers in a given cross-section of a FiberGuide installation. The TracerLight Connector Identification System is ADCs newest patch cord solution. It features slightly different dimensions than standard patch cords.

ADC Recommended Density


1.7 mm Patch Cords 2.0 mm Patch Cords 90 3.0 mm Patch Cords 40

600 mm Products

Recommended Patch Cord Density (per in2)

120

2x6 4x6 4x4 4x12 2x2 FiberGuide System FiberGuide System FiberGuide System FiberGuide System FiberGuide System Trough Pileup 2-inch 3-inch 4-inch

1.7 mm

2.0 mm

3.0 mm 160 -

1.7 mm

2.0 mm

3.0 mm

1.7 mm

2.0 3.0 mm mm

1.7 mm

2.0 3.0 mm mm

1.7 mm

2.0 3.0 mm mm

480 360 -

1440 1080 480 -

960 720 320 1440 1080 480 1920 1440 640

1440 1080 480 2160 1620 720 2880 2160 960

2880 2160 960 4320 3240 1440 5760 4320 1920

Maximum Density
1.7 mm Patch Cords Maximum Patch Cord Density (per in2) 142 2.0 mm Patch Cords 102 3.0 mm Patch Cords 44

100571

2x2 4x4 4x6 4x12 2x6 FiberGuide System FiberGuide System FiberGuide System FiberGuide System FiberGuide System

Trough Pileup 2-inch 3-inch 4-inch

1.7 2.0 3.0 mm mm mm 568 408 176 -

1.7 mm

2.0 mm

3.0 mm

1.7 mm

2.0 mm

3.0 mm

1.7 mm

2.0 3.0 mm mm

1.7 mm

2.0 mm

3.0 mm

10/03

1704 1224 528 -

1136 816 352 1704 1224 528 2272 1632 704

1704 1224 528 3408 2448 1056 2556 1836 792 5112 3672 1584 3408 2448 1056 6816 4896 2112

TracerLight Patch Cords 65 Patch Cords per in2


Trough 2x2 4x4 4x6 4x12 2x6 Pileup FiberGuide System FiberGuide System FiberGuide System FiberGuide System FiberGuide System 2-inch 3-inch 4-inch 260 780 520 780 1040 780 1170 1560 1560 2340 3120

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

89

FiberGuide Fiber Management System


Express Exits
Ordering Information
Description 2-inch Express Exit 4-inch Express Exit base with base cover 4-inch Express Exit rear cover kit Rear cover, 4-inch Express Exit 4x4 system Rear cover, 4-inch Express Exit 4x6 system Rear cover, 4-inch Express Exit 4x12 system Low profile Express Exit Catalog Number FGS-MEXP-A/B/F FGS-MEXP-E-A/B/F FGS-MEXC-E-A/B/F FGS-MEXC-E-A FGS-MEXC-E-B FGS-MEXC-E-F FGS-MEXP-LP-A/B/F

600 mm Products

Express Exits

2x2 Fittings and Junctions


Ordering Information
Description 2x2 2x2 2x2 2x2 2x2 2x2 2x2 2x2 2x2 2x2 horizontal cross with cover horizontal tee with cover 45 horizontal elbow with cover 90 horizontal elbow with cover to 4-inch straight adapter with cover end cap kit (includes junction) 45 up elbow with cover 45 down elbow with cover 90 down elbow with cover junction Catalog Number FGS-MHXP-C FGS-MHTA-C FGS-MH4A-C FGS-MH9A-C FGS-MDSA-AC FGS-HMEC-C FGS-MU4A-C FGS-MD4A-C FGS-MD9A-C FGS-MJWR-C

FGS-MHTA-C

100571

2x2 Straight Section


Ordering Information
Description 6-foot horizontal straight with cover Catalog Number FGS-MSHA-C FGS-MSHA-C

10/03

2x2 Downspout Options


Ordering Information
Description 2x2 standard downspout with cover 2x2 extended downspout with cover 2x2 flex tube attachment with 5-foot length 2-inch flex tube and 2x2 junction 2x2 extended downspout kit with 2-foot length 2-inch flex tube and cover Dual 7/8-inch flex tube attachment with (2) 5-foot lengths flex tube and 2x2 junction Kit of 10 7/8-inch flex tube clamps Catalog Number FGS-MSDS-C FGS-MDSP-C FGS-MEX1-C-5F FGS-KDH2-C FGS-KT03-C FGS-HSHC-10 FGS-MSDS-C

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

90

FiberGuide Fiber Management System


2x2 Direct Support Kits
Ordering Information
Description 2x2 2x2 2x2 2x2 2x2 ladder rack support kit bay top short L bracket kit bay top long L bracket kit digital cableway support kit underfloor support kit Catalog Number FGS-HLR2-C FGS-BTBS-C FGS-BTBL-C FGS-HDCB-C FGS-HUFB-C

600 mm Products

FGS-HLR2-C

2x2 Track Support Kits


Ordering Information
Description Aluminum track support (6-feet) New threaded rod kit (5/8-inch) New threaded rod kit (1/2 -inch) Track connecting bar kit Ladder rack bracket kit (5/8-inch) Threaded rod 12" long Dual threaded rod bracket kit Catalog Number FGS-HASK-C FGS-HTR2-5/8 FGS-HTR2-1/2 FGS-HAEJ-C FGS-HLDR-5/8 FGS-HTHR-5/8-12 FGS-HTUB-2-AB

FGS-HASK-C

2x6 Fittings
Ordering Information
Description 2x6 2x6 2x6 2x6 2x6 2x6 2x6 2x6 2x6 2x6 2x6 2x6 2x6 to 2x2 downspout horizontal T horizontal cross 90 horizontal elbow 90 down elbow 45 horizontal elbow 45 up elbow with cover 45 down elbow to 4x4 adapter to 4x6 adapter trumpet flare end cap Express Exit Catalog Number FGS-MDSP-G FGS-MHRT-G FGS-MHXP-G FGS-MH9E-G FGS-MD9E-G FGS-MH4E-G FGS-MU4E-G FGS-MD4E-G FGS-MDSA-GA FGS-MDSA-GB FGS-MTRM-G FGS-HMEC-G FGS-MEXP-LP-G

10/03

100571

FGS-MSHS-G

2x6 Straight Section


Ordering Information
Description 2x6 horizontal straight section (6-feet) 2x6 horizontal straight section snap-on cover (6-feet) Catalog Number FGS-MSHS-G FGS-MSSC-B/G

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

91

FiberGuide Fiber Management System


2x6 Junction
Ordering Information
Description 2x6 junction Catalog Number FGS-JUNC-G FGS-JUNC-G

4x4 Fittings and Junctions

600 mm Products

Ordering Information
Description 4x4 downspout 4x4 and 4x6 downspout cover 4x4 extended downspout 4x4 and 4x6 extended downspout cover 4x4 horizontal T 4x4 horizontal T cover 4x4 horizontal cross 4x4 horizontal cross cover 4x4 90 horizontal elbow 4x4 90 horizontal elbow cover 4x4 45 horizontal elbow 4x4 45 horizontal elbow cover 4x4 90 up elbow with cover 4x4 90 down elbow 4x4 90 down elbow cover 4x4 45 up elbow with cover 4x4 45 down elbow 4x4 45 down elbow cover 4x4 to 4x6 straight adapter 4x4 to 4x6 straight adapter cover 4x4 end cap 4x4 snap-fit junction 4x4 cut-in T Cut-in T fixture 4x4 IFC tie bracket Catalog Number FGS-MDSP-A FGS-MCDS-AB FGS-MDSP-EX-A FGS-MCDS-EX-AB FGS-MHRT-A FGS-CHRT-A FGS-MHXP-A FGS-CHXP-A FGS-MH9E-A FGS-CH9E-A FGS-MH4E-A FGS-CH4E-A FGS-MU9E-A FGS-MD9E-A FGS-CD9E-A FGS-MU4E-A FGS-MD4E-A FGS-CD4E-A FGS-MDSA-AB FGS-CDSA-AB FGS-HMEC-A FGS-MFAW-A FGS-MHIS-A FGS-MHIS-JIG-A/B/F FGS-HIFC-A

FGS-MDSP-A

FGS-MH9E-A

100571

10/03

FGS-MFAW-A

4x4 Straight Section


Ordering Information
Description 6-foot horizontal straight section 6-foot horizontal straight section hinged cover 4x4 expandable straight section 6-foot horizontal straight section snap-on cover Catalog Number FGS-MSHS-A FGS-MSHC-A FGS-MVAR-A FGS-MSSC-A FGS-MSHS-A

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

92

FiberGuide Fiber Management System


4x4 and 4x6 Downspout Options
Ordering Information
Description 4x4 downspout junction kit 2x2 flex tube attachment with 5-foot length 2-inch flex tube and 2x2 junction 4x4/4x6 downspout insert (adapts to 2x2 system) 4x4 trumpet flare kit 4-inch square to 2-inch round adapter with 5-feet flex tubing 4-inch square to 2-inch round adapter with 10-feet flex tubing 4-inch square to 2-inch round adapter with 15-feet flex tubing 4x4 single flex tube attachment with (1) 5-foot length 2-inch flex tubing 4x4 dual flex tube attachment with (2) 5-foot lengths 2-inch flex tubing Catalog Number FGS-MJWR-A FGS-MEX1-C-5F FGS-HDSI-AB FGS-MTRM-A FGS-ASRI-5F FGS-ASRI-10F FGS-ASRI-15F FGS-KT03-A1 FGS-KT03-A FGS-MDSP-EX-A

600 mm Products

2x6, 4x4 and 4x6 Support Kits


Ordering Information
Description New threaded rod bracket (5/8-inch) New threaded rod bracket (1/2 -inch) Modified new threaded rod bracket (5/8-inch) Existing threaded rod bracket (5/8-inch) Existing threaded rod bracket (1/2 -inch) Modified existing threaded rod bracket (5/8-inch) Center support bracket (5/8-inch) Center support bracket (1/2 -inch) L bay support bracket Digital cableway bracket kit (12-inch) Digital cableway bracket kit (15-inch) Top support C-bracket Top support low profile C-bracket Ladder rack center support bracket kit Threaded rod, 5/8-11x12-inch Threaded rod, 5/8-11x30-inch Threaded rod, 5/8-11x72-inch Auxiliary framing clip kit 5/8-11 thread Auxiliary framing clip kit 1/2 -11 thread Adjacent angle support bracket 5/8-11/36-inch Adjacent angle support bracket 5/8-11/48-inch Adjacent angle support bracket 1/2 -13/36-inch Adjacent angle support bracket 1/2 -13/48-inch Ladder rack bracket kit (5/8-inch) Unistrut nut kit (5/8-inch) Catalog Number FGS-HNTR-5/8 FGS-HNTR-1/2 FGS-HNTR-5/8-A FGS-HETR-5/8 FGS-HETR-1/2 FGS-HETR-5/8-A FGS-HTUB-5/8 FGS-HTUB-1/2 FGS-HLBK FGS-HCBL-12 FGS-HCBL-15 FGS-HNTS-5/8 FGS-HNTS-5/8-LP FGS-HNLR-AB FGS-HTHR-5/8-12 FGS-HTHR-5/8-30 FGS-HTHR-5/8-72 FGS-HFCK-5/8 FGS-HFCK-1/2 FGS-HASB-5/8-36 FGS-HASB-5/8-48 FGS-HASB-1/2-36 FGS-HASB-1/2-48 FGS-HLDR-5/8 FGS-HDGR

100571

FGS-HNTR-XX

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

93

FiberGuide Fiber Management System


4x6 Fittings and Junctions
Ordering Information
Description 4x6 downspout 4x4/4x6 downspout cover 4x6 extended downspout 4x4/4x6 extended downspout cover 4x6 horizontal T 4x6 horizontal T cover 4x6 horizontal cross 4x6 horizontal cross cover 4x6 90 horizontal elbow 4x6 90 horizontal elbow cover 4x6 45 horizontal elbow 4x6 45 horizontal elbow cover 4x6 45 up elbow with cover 4x6 45 down elbow 4x6 45 down elbow cover 4x6 90 down elbow 4x6 90 down elbow cover 4x6 90 up elbow with cover 4x6 cut-in T Cut-in T fixture 4x6 trumpet flare kit 4x6 end cap 4x6 snap-fit junction 4x6 IFC tie bracket Catalog Number FGS-MDSP-B FGS-MCDS-AB FGS-MDSP-EX-B FGS-MCDS-EX-AB FGS-MHRT-B FGS-CHRT-B FGS-MHXP-B FGS-CHXP-B FGS-MH9E-B FGS-CH9E-B FGS-MH4E-B FGS-CH4E-B FGS-MU4E-B FGS-MD4E-B FGS-CD4E-B FGS-MD9E-B FGS-CD9E-B FGS-MU9E-B FGS-MHIS-B FGS-MHIS-JIG-A/B/F FGS-MTRM-B FGS-HMEC-B FGS-MFAW-B FGS-HIFC-B

FGS-MDSP-B

600 mm Products

FGS-MFAW-B

FGS-MU9E-B

100571

4x6 Straight Section


Ordering Information
Description 6-foot horizontal straight section 6-foot horizontal straight section hinged cover 4x6 expandable straight section 6-foot horizontal straight section snap-on cover Catalog Number FGS-MSHS-B FGS-MSHC-B FGS-MVAR-B FGS-MSSC-B/G

10/03

FGS-MSHS-B

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

94

FiberGuide Fiber Management System


4x12 Fittings
Ordering Information
Description 4x12 horizontal T 4x12 horizontal T cover 4x12 to 4x6 horizontal T 4x12 to 4x6 horizontal T cover 4x12 horizontal cross 4x12 horizontal cross cover 4x12 to 4x6 horizontal cross 4x12 to 4x6 horizontal cross cover 4x12 to 4x6 adapter 4x12 to 4x6 adapter cover 4x12 90 horizontal elbow 4x12 90 horizontal elbow cover 4x12 45 horizontal elbow 4x12 45 horizontal elbow cover 4x12 end cap 4x12 cut-in T Cut-in T fixture 4x12 45 up elbow 4x12 45 up elbow cover 4x12 45 down elbow 4x12 45 down elbow cover 4x12 90 down elbow 4x12 90 down elbow cover 4x12 trumpet flare kit 4x12 downspout with 4x6 exit 4x12 downspout with rear T 4x12 to dual 4x6 adapter 4x12 IFC tie bracket Catalog Number FGS-MHRT-F FGS-SHRT-F FGS-MHRT-F/B FGS-SHRT-F/B FGS-MHXP-F FGS-SHXP-F FGS-MHXP-B/F FGS-SHXP-B/F FGS-MDSA-FB FGS-SDSA-FB FGS-MH9E-F FGS-SH9E-F FGS-MH4E-F FGS-SH4E-F FGS-HMEC-F FGS-MHIS-F FGS-MHIS-JIG-A/B/F FGS-MU4E-F FGS-SU4E-F FGS-MD4E-F FGS-SD4E-F FGS-MD9E-F FGS-SD9E-F FGS-MTRM-F FGS-MDSP-F FGS-MDRT-F FGS-MDSA-F2B FGS-HIFC-F

600 mm Products

FGS-MH9E-F

100571

Covers are available for 4x12 fittings. Please contact ADC or visit www.adc.com

4x12 Straight Section


Ordering Information
Description 6-foot horizontal straight section 4x12 expandable straight section 6-foot snap-on cover Catalog Number FGS-MSHS-F FGS-MVAR-F FGS-MSSC-F

10/03

FGS-MSHS-F

4x12 Junction
Ordering Information
Description 4x12 snap-fit junction Catalog Number FGS-MFAW-F FGS-MFAW-F

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

95

FiberGuide Fiber Management System


4x12 System Support Kits
Ordering Information
Description New threaded rod bracket (5/8-inch) Existing threaded rod bracket (5/8-inch) Top support threaded rod bracket kit Top support low profile threaded rod bracket kit Trapeze bracket kit Ladder rack center support bracket kit Catalog Number FGS-HNTR-F-5/8 FGS-HETR-F-5/8 FGS-HNTS-F-5/8 FGS-HNTS-F-5/8-LP FGS-HNTP-F-5/8 FGS-HNLR-F

600 mm Products

Vertical Duct Systems


Ordering Information
Description 2x2 vertical slotted duct kit, 6-feet 2x2 vertical 1.5-inch slotted duct kit, 6-feet 2x2 vertical solid duct 1x2 vertical duct kit 1x2 solid vertical duct kit 2x2 vertical to 1x2 vertical adapter bracket 2x2 vertical slotted duct, 6-feet 2x2 vertical 1.5-inch slotted duct, 6-feet Cover for 2x2 vertical duct, 6-feet 2x2 vertical duct mounting bracket 4x4 vertical duct kit 4x4 vertical adapter junction kit 4x4 vertical slotted duct, 6-feet Cover for 4x4 vertical duct, 6-feet 4x4 vertical duct mounting bracket Catalog Number FGS-KTW1-C FGS-KTW1-CA FGS-KTW4-C FGS-KTW1-E FGS-KTW4-E FGS-ACC063 FGS-MSHS-C FGS-MSHS-CA FGS-MSHC-C FGS-HWMB-C FGS-KTW2-D FGS-MJWR-D FGS-MSHS-D FGS-MSHC-C FGS-HWMB-D

FGS-KTW2-D

100571

Accessories
Ordering Information
Description Flex Tubing 2-inch outer diameter slotted flex tube, 5-feet 2-inch outer diameter slotted flex tube, 10-feet 2-inch outer diameter slotted flex tube, 15-feet 1-inch outer diameter slotted flex tube, 100-feet 1-inch outer diameter slotted flex tube, 150-feet 1-inch outer diameter slotted flex tube, 200-feet 1-inch outer diameter slotted flex tube, 250-feet 7/8-inch outer diameter slotted flex tube, 5-feet 7/8-inch outer diameter slotted flex tube, 10-feet 7/8-inch outer diameter slotted flex tube, 15-feet 7/8-inch outer diameter slotted flex tube, 200-feet Accessories Hinge kit for 4x4 and 4x6 covers (kit of 1) Self-closing hinge (kit of 3) Retainer rings (kit of 10) Trough cover clip kit Mitre box and saw Quick knobs (10) Quick knobs (100) Flex tube clamps (kit of 10)
www.adc.com

Catalog Number

FGS-MIDY-5F FGS-MIDY-10F FGS-MIDY-15F FGS-MLDY-100F FGS-MLDY-150F FGS-MLDY-200F FGS-MLDY-250F FGS-MFTY-5F FGS-MFTY-10F FGS-MFTY-15F FGS-MFTY-200F FGS-HHGK FGS-HVHG FGS-HFRR-10 FGS-KT09 FGS-MKIT-ABF FGS-KQKB FGS-HQKK FGS-HHEC-10

10/03

FGS-MIDY

+32-2-712-65-00

+32-2-712-65-42

96

Plenum FiberGuide System


System Description
ADCs Plenum FiberGuide System is a fiber cable trough system that protects optical fibers routed beneath raised computer room floors and above suspended ceilings. These physical areas, used to transport environmental air, are typically categorized as plenum air spaces by National Electric Code (NEC) Standards. In general, materials used in these spaces must be nonflammable and must not emit appreciable amounts of smoke or toxic gases when exposed to heat or flame.

Dropped Ceiling

Fiber Distribution Devices

600 mm Products

Made from sturdy aluminum, ADCs Plenum FiberGuide System protects optical fibers by physically separating them from copper communications cable, power cable, ground cables, heating/ventilating duct, water pipes and many other obstructions commonly encountered in plenum air spaces. As seen in Figure 1, the Plenum FiberGuide System can be used above a dropped ceiling as well as below a raised computer floor.

Fiber Optic Equipment

Raised Floor

Figure 1

Horizontal Tee and Conversion at Branches Horizontal Tee

Figure 2 details a layout below a computer floor. All plenum components, including mounting hardware for mounting the FiberGuide to the raised floor struts, are available in the Plenum FiberGuide product line.

100571

90 Horizontal Elbow Support Kit at Two Foot Intervals

Up Elbow and Trumpet Flare at Equipment Interface Figure 2

10/03

For complete ordering information, please contact ADC or visit www.adc.com

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

97

Plenum FiberGuide System


System Description
Straight sections: U-shaped troughs that provide a protective guideway for optical fibers. Straight sections are usually installed horizontally but may also be installed vertically when a system is mounted on multiple levels. Straight sections are 6 feet in length; covers are also available. The covers snap into place but can be easily removed for installing fibers. Fittings: Elbows, tees, crosses, trumpet flares, and conversions. The fittings are used for changing direction, converting from one size system to another, adding branch segments, and routing the fibers into and out of the system. Like the straight sections, snap-on covers are also available for the fittings. Junction kits: Used for aligning and connecting straight sections and fittings. Two components are joined by inserting both components into a junction and then pushing them together.

600 mm Products
100571

Support kits: Used to support the Plenum FiberGuide system. The short, long, span, and diagonal bracket kits are used for supporting straight sections from round or square tubing. Flexible tubing: Used in Plenum FiberGuide systems when the exact layout of the equipment drop locations is unknown or when frequent equipment relocations are expected. The flexible tubing is 2 inches in diameter and attaches to the end of a 2x2, 4x6, or 4x12 straight section with an adapter. When the equipment configuration is known, the flexible tubing is routed to the exact drop location. Other flexible tubing components include splicing couplers, finishing couplers, mounting straps, and additional lengths of tubing. Both patch cords and IFC cables may be installed in the Plenum FiberGuide system. The required 2-inch bend radius for patch cords is maintained at all points within the system. Intrafacility cables require the use of tie down brackets to maintain the required cable bend radius (specified by cable manufacturer) at the various fittings.

10/03

2x2 Horizontal Straight Section

4x6 Horizontal Straight Section

4x12 Horizontal Straight Section

2x2, 4x6, and 4x12 Junction Kits

For complete ordering information, please contact ADC or visit www.adc.com

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

98

Plenum FiberGuide System


Recommended Patch Cord Densities
Recommended capacity takes into consideration random jumper placement into the FiberGuide system. Trough capacity refers to the maximum number of fiber jumpers in a given cross-section of a FiberGuide installation.

Recommended Density
Single Patch Cords 1.7 mm Recommended Patch Cord Density (per in2) 120 2.0 mm 90 3.0 mm 40

600 mm Products

Trough Pile-up 2 inch 3 inch 4 inch

2x2 FiberGuide System 1.7 mm 480 2.0 mm 360 3.0 mm 160 -

4x6 FiberGuide System 1.7 mm 1440 2.0 mm 1080 1620 2160 3.0 mm 480 720 960

4x12 FiberGuide System 1.7 mm 2880 4320 5760 2.0 mm 2160 3240 4320 3.0 mm 960 1440 1920

Using Lab Manual Set-ups Pile-up beyond 2 inches is not recommended

Maximum Density
1.7 mm 2.0 mm 3.0 mm Patch Cords Patch Cords Patch Cords Maximum Patch Cord Density (per in2)

100571

142

102

44

10/03

2x2 FiberGuide System Trough Pile-up 2 inch 3 inch 4 inch 1.7 mm 568 2.0 mm 408 3.0 mm 176 -

4x6 FiberGuide System 1.7 mm 1704 2556 3408 2.0 mm 1224 1836 2448 3.0 mm 528 792 1056

4x12 FiberGuide System 1.7 mm 3408 5112 6862 2.0 mm 2448 3672 4896 3.0 mm 1056 1584 2112

Using GR-449-CORE Bellcore Formula

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

99

Plenum FiberGuide System


2x2 System (2" H x 2" W)
The 2x2 Plenum FiberGuide system interfaces with ADCs standard 2x2 FiberGuide System and requires no special conversion piece.
Ordering Information
Catalog Number Description Straight section 2x2 straight section - length: 6' Fittings 2x2 horizontal T 2x2 horizontal cross 2x2 90 horizontal elbow 2x2 45 horizontal elbow 2x2 90 up elbow 2x2 90 down elbow 2x2 45 up elbow 2x2 45 down elbow Trumpet flares 2x2 trumpet flare 3 sided 2x2 trumpet flare 4 sided Conversions 2x2 plenum to 4x6 plenum conversion 2x2 plenum to 4x12 plenum conversion Junctions 2x2 junction 2x2 end cap requires 2x2 junction Fitting PFGF-PSHS-C PFGF-PHRT-C PFGF-PHXP-C PFGF-PH9E-C PFGF-PH4E-C PFGF-PUPE-C PFGF-PDNE-C PFGF-PU4E-C PFGF-PD4E-C PFGF-PTRM-C PFGF-PFPT-C PFGF-PDSA-C/B PFGF-PDSA-C/F PFGF-PJWR-C PFGF-PMEC-C Snap-on Cover PFGC-PSHS-C PFGC-PHRT-C PFGC-PHXP-C PFGC-PH9E-C PFGC-PH4E-C PFGC-PUPE-C PFGC-PDNE-C PFGC-PU4E-C PFGC-PD4E-C PFGC-PDSA-C/B PFGC-PDSA-C/F Number of Junctions 3 4 2 2 2 2 2 2 (1) 2x2 (1) 4x6 (1) 2x2 (1) 4x12

10/03

100571

600 mm Products

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

100

Plenum FiberGuide System


4x6 System (4" H x 6" W)
Ordering Information
Catalog Number Description Straight section 4x6 straight section 6' long Fitting PFGF-PSHS-B PFGF-PHRT-B PFGF-PHXP-B PFGF-PH9E-B PFGF-PH4E-B PFGF-PUPE-B PFGF-PDNE-B PFGF-PU4E-B PFGF-PD4E-B PFGF-PTRM-B PFGF-PFPT-B PFGF-PPSC-B Snap-on Cover PFGC-PSHS-B PFGC-PHRT-B PFGC-PHXP-B PFGC-PH9E-B PFGC-PH4E-B PFGC-PUPE-B PFGC-PDNE-B PFGC-PU4E-B PFGC-PD4E-B Number of Junctions 3 4 2 2 2 2 2 2 1*

600 mm Products

Fittings 4x6 horizontal T 4x6 horizontal cross 4x6 90 horizontal elbow 4x6 45 horizontal elbow 4x6 90 up elbow 4x6 90 down elbow 4x6 45 up elbow 4x6 45 down elbow Trumpet flares 4x6 trumpet flare 3 sided 4x6 trumpet flare 4 sided Conversions 4x6 plenum to 4x6 standard conversion * One 4x6 plenum junction kit required; 4x6 standard junction is not required 4x6 plenum to 12" plenum conversion Junctions 4x6 junction 4x6 end cap requires 4x6 junction

PFGF-PDSA-B/F PFGF-PJWR-B PFGF-PMEC-B

PFGC-PDSA-B/F

(1) 4x6, (1) 4x12

100571

4x12 System (4" H x 12" W)


Ordering Information
Catalog Number Description Straight section 4x12 straight section 6' long Fittings 4x12 horizontal T 4x12 horizontal cross 4x12/4x6 horizontal T 4x12 90 horizontal elbow 4x12 45 horizontal elbow 4x12 90 up elbow 4x12 90 down elbow 4x12 45 up elbow 4x12 45 down elbow Trumpet flares 4x12 trumpet flare 3 sided 4x12 trumpet flare 4 sided Junctions 4x12 junction 4x12 end cap requires 4x12 junction Fitting PFGF-PSHS-F PFGF-PHRT-F PFGF-PHXP-F PFGF-PHRT-F/B PFGF-PH9E-F PFGF-PH4E-F PFGF-PUPE-F PFGF-PDNE-F PFGF-PU4E-F PFGF-PD4E-F PFGF-PTRM-F PFGF-PFPT-F PFGF-PJWR-F PFGF-PMEC-F Snap-on Cover PFGC-PSHS-F PFGC-PHRT-F PFGC-PHXP-F PFGC-PHRT-F/B PFGC-PH9E-F PFGC-PH4E-F PFGC-PUPE-F PFGC-PDNE-F PFGC-PU4E-F PFGC-PD4E-F Number of Junctions 3 4 (2) 4x12, (1) 4x6 2 2 2 2 2 2

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

101

Plenum FiberGuide System


Accessories (Support Bracket Kits)
Ordering Information
Description Short bracket kit for use with 2x2 and 4x6 sizes; 8.21" overall length Short bracket kit with square U-bolt for easy access mounting Long bracket kit for use with 2x2, 4x6, and 4x12 sizes; 18.84" overall length Long bracket kit with square U-bolt for easy access mounting Span bracket kit for use with 2x2, 4x6, and 4x12 sizes; spans 24" center to center floor struts Span bracket kit with square U-bolt for easy access mounting Diagonal span bracket kit for use with 2x2, 4x6, and 4x12 sizes; spans diagonally up to 34" between struts Diagonal span bracket kit with square U-bolt for easy access mounting All support bracket kits fit round support pedestals sizes 0.5" to 1.125". Catalog Number PFGF-SSPT-C/B PFGF-EASSPT-C/B PFGF-LSPT-C/B/F PFGF-EALSPT-C/B/F PFGF-ESPT-C/B/F PFGF-EAESPT-C/B/F PFGF-DSPT-C/B/F PFGF-EADSPT-C/B/F

600 mm Products

Accessories (Flexible Tubing)


Ordering Information
Description One hose adapter, with 5' (1.53 m) hoses and finishing couplers Two hose adapter, with 5' (1.53 m) hoses and finishing couplers Extension tube, 5' (1.53 m) long with splice coupler Finishing coupler Mounting strap Splicing coupler Flexible tubing, 2" (5.08 cm) inner diameter (X = length in feet: 5, 15, 35, 75, 110, 150) Tie down bracket for IFC Catalog Number PFGF-KT03-C PFGF-KT03-B PFGF-HEXT PFGF-HFIN PFGF-HMST PFGF-HSPL PFGF-MIDY-XFI PFGF-PIFC

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

102

PowerWorx Power Distribution Products


Select Series Fuse Platform
As data and telephony converge, network elements with varying amperage requirements are often mixed within the same bay. The Select Series fuse platform enables service providers to fuse this equipment from one platform, in a single rack unit, making the most of valuable space. Its compact footprint and versatility are well-suited for collocation applications where high-amperage equipment such as routers, DSLAMs, and SONET gear is installed with lower-amperage equipment. Its patent-pending modular design enables service providers to combine TPA, KTK/KLM, TPM or GMT fuses within a single rack unit. Input power up to 100 Amps per bus with up to 50 Amps output power per fuse position is available.

600 mm Products

Catalog Number PWX-041 R C S Panel Color and Mounting P W Putty white, EIA/WECO mounting Putty white, ETSI mounting Access R Standard (front and rear access) Powering Input C Two-hole compression lug (stud type)

Fuse Configuration A2 G4* A2 G5** A2 G1** A2 XX A4 G4* A4 G5** A4 G1** A4 XX K2 G4* K2 G5** K2 G1** K2 XX K3 G4* K3 G5** K3 G1** K3 XX K4 G4* K4 XX K5 XX M2 G4* M2 G5** M2 G1 M2 XX M3 G4* M3 G5** M3 G1** M3 XX M4 G4* M4 XX M5 XX G1 XX** 2 TPA, 4 GMT 2 TPA, 5 GMT 2 TPA, 10 GMT 2 TPA per bus 4 TPA, 4 GMT 4 TPA, 5 GMT 4 TPA, 10 GMT 4 TPA per bus 2 KLM/KTK, 4 GMT 2 KLM/KTK, 5 GMT 2 KLM/KTK, 10 GMT 2 KLM/KTK per bus 3 KLM/KTK, 4 GMT 3 KLM/KTK, 5 GMT 3 KLM/KTK, 10 GMT 3 KLM/KTK per bus 4 KLM/KTK, 4 GMT 4 KLM/KTK per bus 5 KLM/KTK per bus 2 TPM, 4 GMT 2 TPM, 5 GMT 2 TPM, 10 GMT 2 TPM per bus 3 TPM, 4 GMT 3 TPM, 5 GMT 3 TPM, 10 GMT 3 TPM per bus 4 TPM, 4 GMT 4 TPM per bus 5 TPM per bus 10 GMT per bus

Alarm Contact Connection W Wire-wrap S Screw-down barrier terminal strip LED Configuration P F Power on and fuse alarm LEDs Fuse alarm LED only

100571

Powering Output S Screw-down barrier terminal strip

Dual Input Power Configuration Y N Dual bus configuration Single bus configuration

10/03

* G4 configurations accept fuses rated up to 15 Amps. ** G1 and G5 configurations accept fuses up to 10 Amps.

In this combination, center to center spacing is 0.250". Distance between barrier walls is 0.200" (3-48 screw post). This applies only for the GMT terminal block. Note: Other configurations are available upon request.

For complete specifications, please contact ADC.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

103

PowerWorx Power Distribution Products


Uninterrupted Power GMT Series

600 mm Products

To ensure constant powering of fused network equipment, the Uninterrupted Power GMT Series features two input power feeds. If power to one fails, the other serves as backup taking on the load of the failed circuit while maintaining its own load. Schottky-steering diodes ensure panel uptime until input power is restored, while a patent-pending heat dissipation design ensures safety. The panel offers input power up to 60 Amps per bus.

Catalog Number PWX-011 G D10 P

Access R Standard (front and rear access) F Total front access (no rear access) Fuse Type G GMT Powering Input C Two-hole compression lug (stud type) S Set screw barrel connector Powering Output S Screw-down barrier terminal strip B Set screw barrel terminal strip Fuse Configuration* D10 Dual power feed, 10/10 position P

Panel Color P Putty white B Black Mounting Option** D EIA/WECO E ETSI Alarm Contact Connection W S Wire-wrap Screw-down barrier terminal strip

100571

LED Configuration Power on and fuse alarm LEDs (per fuse holder)

10/03

CHASSIS HEIGHT STANDARD TOTAL FRONT ACCESS 1.75" (4.44 cm) 3.50" (8.89 cm)

*Custom fuse panel configurations available with certain minimums **EIA (Electronic Industries Association), WECO (Western Electric Company), ETSI (European Telecommunications Standards Institute)

For complete specifications, please contact ADC.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

104

PowerWorx Power Distribution Products


Traditional GMT Series
With input power up to 65 Amps per bus, the Traditional GMT Series eliminates the need to stock varying amperage fuse panels. Fuse management is simplified by accommodating up to 15 Amps of output power per fuse position without the need to space fuses. A self-configuring voltage and polarity feature allows a single panel to support most applications, providing 24Vdc or 48Vdc power.

600 mm Products

Catalog Number PWX-001 G

Access R Standard (front and rear access) F Total front access (no rear access) Fuse Type G GMT Powering Input C Two-hole compression lug (stud type) S Set screw barrel connector Powering Output S Screw-down barrier terminal strip B Set screw barrel terminal strip

Panel Color P Putty white B Black Mounting Option** D EIA/WECO E ETSI Alarm Contact Connection W S Wire-wrap Screw-down barrier terminal strip

LED Configuration P F Power on and fuse alarm LEDs (per fuse holder) Fuse alarm LED only (per fuse panel)

100571

Fuse Configuration*

STANDARD

CHASSIS HEIGHT TOTAL FRONT ACCESS

10/03

S10 S20 S40 D10 D20

Single power feed, 10 position Single power feed, 20 position Single power feed, 40 position Dual power feed, 10/10 position Dual power feed, 20/20 position

1.75" (4.44 cm) 1.75" (4.44 cm) 1.75" (4.44 cm) 1.75" (4.44 cm) 1.75" (4.44 cm)

1.75" (4.44 cm) 3.50" (8.89 cm) 3.50" (8.89 cm) 3.50" (8.89 cm) 3.50" (8.89 cm)

*Custom fuse panel configurations available with certain minimums **EIA (Electronic Industries Association), WECO (Western Electric Company), ETSI (European Telecommunications Standards Institute)

For complete specifications, please contact ADC.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

105

PowerWorx Power Distribution Products


Advantage Series Platform

600 mm Products

The Advantage Series platform accepts input power up to 300 Amps per bus, up to 125 Amps per high-current output position, and up to 15 Amps per GMT fuse position (optional). A patent-pending design, the Advantage Series platform can be configured to meet unique network powering needs. Select from various input power cable routing types, fusing options and alarm connectors. Industry standard bullet terminal breakers or fuses can be mixed within a single panel, allowing maximum flexibility. PowerWorx panels are independently tested to comply with the industrys highest standards, including CE, IEC, UL, NEBS Level 3, Telcordia (Bellcore), CSA, and NEC 2002. Compact, flexible PowerWorx configurations suit most network applications. Using the universal mounting brackets, the panel can be flush- or recess-mounted into 19-inch (48.3 cm) and 23-inch (58.4 cm) Electronic Industries Association (EIA) and Western Electric Company (WECO) racks.

Catalog Number PWX-061R__ D __ 6 __ __ __ __ __ P

100571

Bus D

Dual

Color P Putty Alarm Terminal Type S Screw-down W Wire-wrap Input Cabling T X Top-down with GMT fuses No GMT fuses

High-Current Output Per Bus 6 6-position

10/03

GMT Fuses Y N Yes (4/bus) No

GMT Output Connector S X Screw-down No GMT fuses requested

For complete specifications, please contact ADC.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

106

PowerWorx Power Distribution Products


Advantage Series Platform Accessories
*Carling Breakers 1 AMP: CA1-X0-09-571-A21-MG 10 AMP: CA1-X0-09-572-A21-MG 20 AMP: CA1-X0-09-573-A21-MG 30 AMP: CA1-X0-09-574-A21-MG 40 AMP: CA1-X0-09-575-A21-MG 50 AMP: CA1-X0-09-576-A21-MG 60 AMP: CA1-X0-09-577-A21-MG 75 AMP: CA1-X0-09-578-A21-MG 90 AMP: CA1-X0-09-634-A21-MG 100 AMP: CA1-X0-09-635-A21-MG *TPC Fuses/Fuse Holder 15 AMP: TPC-15 20 AMP: TPC-20 25 AMP: TPC-25 30 AMP: TPC-30 40 AMP: TPC-40 50 AMP: TPC-50 60 AMP: TPC-60 75 AMP: TPC-75 90 AMP: TPC-90 100 AMP: TPC-100 125 AMP: TPC-125 *TPC Fuse Holder - TPCDS-BBE-2

600 mm Products

*Other ratings upon request.

Compression Lugs For Two-Hole Stud-type Input Power Connections


Compression lugs provide a robust and reliable electro-mechanical connection.
Ordering Information
Description Compression lug, ships two per pack 2 AWG 1 AWG 1/0 AWG 2/0 AWG 3/0 AWG 4/0 AWG 250 KCMil 300 KCMil 350 KCMil Catalog Number CL-02M CL-01M CL-01M0 CL-02M0 CL-03M0 CL-04M0 CL-250M CL-300M CL-350M

100571

10/03

Miscellaneous Accessories
Ordering Information
Description Circuit breaker fingerguards, ships 12 per pack Circuit breaker/TPC fuse designation cards, ships 12 per pack *TPC fuse holder adapter, ships 12 per pack Catalog Number FG-01A DCK-01A FHA-01A

Fingerguard FG-01A Front View

Fingerguard FG-01A Side View

Designation Card DCK-01A

FHA-01A

* Required for mounting TPC fuse holder in Advantage Platform

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

107

PowerWorx Accessories
GMT Fuse Puller
The compact puller grips firmly to remove GMT fuses.
Ordering Information
Description Fuse puller, ships two per pack Catalog Number FP-G

600 mm Products

Designation Card Holder and Cards


Designation cards held in pressure-sensitive card holder enable easy identification and location of fused equipment.
Ordering Information
Description Designation card holder kit Includes: 1 plastic designation card holder 2 designation cards and window Catalog Number DCK-02

GMT Designation Pin Holder


GMT designation pin holder securely holds designation pins for improved fuse value identification.
Ordering Information
Description GMT designation pin holder ships two per pack Holds up to ten fuse designation pins Adhesive back allows for quick and easy mounting Catalog Number DPK-01

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

108

PowerWorx Accessories
Fuses
Ordering Information
Description TPA Fuses Alarm Indicator 3 5 10 15 20 25 30 40 50 Amps Amps Amps Amps Amps Amps Amps Amps Amps TPA-03 TPA-05 TPA-10 TPA-15 TPA-20 TPA-25 TPA-30 TPA-40 TPA-50 Catalog Number Description KLM Fuses Non-Indicator* 5 Amps 10 Amps 15 Amps 20 Amps 25 Amps 30 Amps KLM Dummy KLM-05 KLM-10 KLM-15 KLM-20 KLM-25 KLM-30 KLM Dummy Catalog Number

600 mm Products

* All KLM fuse modules house a fuse alarm indicating red LED.

Ordering Information
Description TPM Fuses Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Disconnect, English Miniature Disconnect, Metric 3 Amp 4 Amp 5 Amp 6 Amp 7 Amp 8 Amp 10 Amp 12 Amp 15 Amp 20 Amp 25 Amp 30 Amp 3-30 Amp 3-30 Amp TPM-03 TPM-04 TPM-05 TPM-06 TPM-07 TPM-08 TPM-10 TPM-12 TPM-15 TPM-20 TPM-25 TPM-30 TPMDS-E TPMDS-M Ampere Rating Catalog Number

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

109

PowerWorx Accessories
GMT Fuses/Fuse Designation Pins Alarm Indicator
Ordering Information
Fuse Size 2/10 Amps 1/4 Amps 3/8 Amps 1/2 Amps 3/4 Amps 1 Amps 1-1/3 Amps 1-1/2 Amps 2 Amps 2-1/2 Amps 3 Amps 3-1/2 Amps 4 Amps 5 Amps 7-1/2 Amps 10 Amps 12 Amps 15 Amps Dummy GMT Color of Indicator Black-Red Violet White-Green Red Brown Gray White White-Yellow Orange Orange-White Blue White-Blue White-Brown Green Black-White Red-White Yellow-Green Red-Blue Fuse Catalog Number F-2/10 F-1/4 F-3/8 F-1/2 F-3/4 F-1 F-1 1/3 F-1 1/2 F-2 F-2 1/2 F-3 F-3 1/2 F-4 F-5 F-7 1/2 F-10 F-12 F-15 GMT Dummy Pin Catalog Color of Designation Pin Number Black-Red Violet White-Green Red Brown Gray White White-Yellow Orange Orange-White Blue White-Blue White-Brown Green Black-White Red-White Yellow-Green Red-Blue P-2/10 P-1/4 P-3/8 P-1/2 P-3/4 P-1 P-1 1/3 P-1 1/2 P-2 P-2 1/2 P-3 P-3 1/2 P-4 P-5 P-7 1/2 P-10 P-12 P-15

600 mm Products

Compression Lugs For Two-Hole Stud-type Input Power Connections


Compression lugs provide a robust and reliable electro-mechanical connection.

100571

Ordering Information
Description Compression lug, ships two per pack 2 AWG 4 AWG 6 AWG 14 AWG Catalog Number CL-02M CL-04M CL-06M CL-14M

10/03

Cable Management Bars For Standard (Front and Rear Access) Fuse Panels
Ordering Information
Description Cable management bar Putty white Catalog Number CMB-P-19

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

110

DSX Modular Rear Cross-Connect


RZX-3 Modules

600 mm Products

RZX-3 Chassis

RZX-3 is designed as a total system solution not just components. Focused on simplifying the solution, the system approach provides ease of expansion, streamlines cross-connect jumper installation and reduces premature jumper exhaustion. And with one part number ordering, engineering, purchasing and installation labor is greatly reduced. Highest Density With the possibility of 336 midsize jack ports utilizing BNC connector interfaces in a 2.2 m rack, the new RZX-3 has more capacity than any other midsize DSX available.

Cable Management
Superior cable management all within the 600 mm footprint.

Flexibility
With its plug and play architecture, the RZX-3 system is fully modular throughout chassis, circuit frames and jacks. Individual BNC circuit frames remove easily from the chassis, providing the most simplified and cost-effective restoral capabilities available.

100571

Durability
ADCs robust DSX jack is constructed with mechanical support to ensure long service life, unlike the lower quality solder-type connections on a printed circuit board often found in other systems. The die-cast coaxial jacks are rigorously tested with over 10,000 insertion/withdrawal cycles. The solid cylinder design has a closed entry contact to prevent spring contact overstress.

Reliability

10/03

ADC doesn't use Teflon insulators, ensuring true 75 Ohm impedance. RZX-3s sealed jack has firewall protection preventing environmental contaminants from disturbing switch contacts.

Make-Before-Break Switching Contacts


Make-before-break contacts ensure that high speed signals never go open or unterminated during inservice patching. DS3 signals are always terminated to a 75 Ohm load, preventing signal oscillation that can lead to bit errors during patching.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

111

DSX Modular Rear Cross-Connect


RZX-3 Modules
Each module provides an IN and OUT switching jack for direct access to the network elements input and output signals. These jacks provide a means to temporarily break the connection between network elements that are cross-connected together and allow access to the signals for test and patching operations. A MONITOR jack with a high impedance bridge network (21.5 dB below the active signal) is connected to the OUT jack for nonintrusive access to the output signal of each network element.
3-Port: IN and OUT switching jacks and a single MONITOR jack 4-Port: IN and OUT switching jacks and a dual MONITOR jack 6-Port: IN and OUT switching jacks and a dual MONITOR jack

600 mm Products

The rear cross-connect modules have jacks for temporary access on the front of the modules, permanent equipment cable interface connections on the rear of the modules, and semi-permanent cross-connect interface connections on the rear of the modules. RZX-3 modules have rear BNC or 1.6/5.6 connectors staggered high and low across the chassis in order to obtain the ultimate in system density. Modules may be ordered individually or in multipack kits. Module kits include a combination of BNC or 1.6/5.6 high and BNC or 1.6/5.6 low modules.
Ordering Information
Module Type 6-port module, BNC 3-port module, 1.6/5.6 4-port module, 1.6/5.6 6-port module, 1.6/5.6 Description Dual monitor Single monitor Dual monitor Dual monitor Odd Chassis Position DSX-4R-MB160 DSX-4R-MG130 DSX-4R-MG140 DSX-4R-MG160 Even Chassis Position DSX-4R-MB260 DSX-4R-MG230 DSX-4R-MG240 DSX-4R-MG260

100571

Module Rear View

3 Port Module

4 Port Module

10/03

MONITOR OUT

MONITOR OUT MONITOR

MONITOR OUT X-OUT MONITOR IN X-IN

IN IN

3-Port provides monitoring to OUT jack only

4-Port provides monitoring for both IN and OUT jacks

6-Port provides monitoring for both IN and OUT jacks and access to the cross-connect

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

112

DSX Modular Rear Cross-Connect


RZX-3 Chassis
The RZX-3 rear cross-connect system supports 24 terminations in a single chassis. For easy circuit identification, LEDs are mounted on the front and the rear of the chassis. The chassis has a rear cable tray to accommodate maximum cable density.

Features
Empty classes mounts in 600 mm DSX-3 skeleton bay (IBR-3RSC001) Red flashing LED on front and rear of the chassis for easy circuit identification Rear cable tray to accommodate the maximum cable density

600 mm Products

Ordering Information Description Empty chassis accommodates 24 terminations Catalog Number DSX4R-D24

Preterminated Option
Each position of the preterminated chassis is equipped with a circuit frame including BNC receptacles. Network elements are cabled during initial installation. When service turn-up is required, a jack kit is plugged into the circuit frame to complete the circuit and provide jack access for testing and patching. Each jack kit consists of an upper and lower jack.
RZX-3 Chassis

100571

Ordering Information
Description Preterminated chassis Allows network elements to be cabled to the chassis without deploying the jacks. This allows the cost of jacks to be deferred until revenue is generated. Catalog Number DSX4R-24B0-D24

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

113

DSX Modular Rear Cross-Connect


RZX-3 Skeleton Bay
ADC offers skeleton bays, preassembled bays with all cable and jumper management, but no chassis or modules. Preprovisioning all cable management ensures that existing jumpers need never be touched when chassis are added to the bay. Jumper routing is never restricted since all wireways are preprovisioned.
Ordering Information
Description Catalog Number IBR-D3S002

600 mm Products

600 mm skeleton bay Preassembled with all cable and jumper management. The frame supports 14 chassis or a total of 336 terminations. Chassis and modules are ordered separately.

RZX-3 End Guard


The end guard offers protection and a finished appearance to the beginning and end of the lineup.
Ordering Information
Description RZX-3 end guard Catalog Number RAC-0B0748

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

114

Digital Distribution Frame System

600 mm Products

Features
Provides bidirectional, nonintrusive signal testing Supports E1 (2.048 Mbps), E3 (34.368 Mbps), or STM-1 (155.52 Mbps) signal rate applications Modular design allows for capital investment to coincide with revenue growth Mounts in standard 600 mm bays Quality cable management and circuit identification markings

Application
The Digital Distribution Frame system (DDF) is used primarily in collocation environments and customer premises as a connection point between NEs. Each NE is semi-permanently cabled to IN/OUT connectors in either the front or rear of each module. The digital signal is accessed through the two MON OUT connectors on the front of each module for testing and monitoring. These dual monitor ports allow access to both directions of the circuit from a single location. This saves valuable technician time when the other side of the termination is located far away, in another room, or is inaccessible.

100571

Network Element A

DMM
OUT
MON Z-OUT

Network Element Z
Tx OUT Rx IN

IN OUT IN

Tx OUT Rx IN
MON A-OUT

10/03

Test Unit

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

115

Digital Distribution Frame System


Modules
Features
Front, dual monitor ports on all module styles BNC or 1.6/5.6 connectors provide true 75 Ohm characteristic impedance All module styles are compatible with any DMM 600 mm chassis style

Ordering Information

600 mm Products

Connector Type BNC BNC BNC bulkhead 1.6/5.6 1.6/5.6 1.6/5.6 bulkhead Blank plate

IN/OUT Connector Locations Rear Front and Rear Front and Rear Rear Front and Rear Front and Rear N/A

Catalog Number DMM-BBNCMF DMM-BBNCF DMM-BBNCBLK DMM-1656MF DMM-1656F DMM-1656BLK DMM-BLANK

100571

DMM-BBNCMF Rear and Front View

DMM-BBNCF Rear and Front View

DMM-BBNCBLK Rear and Front View

10/03

DMM-1656MF Rear and Front View

DMM-1656F Rear and Front View

DMM-1656BLK Rear and Front View

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

116

Digital Distribution Frame System


Standard Configuration
Features
288 total circuits in fully loaded bay Cable bars and front cable trays, with cable tiedowns, reduce cable congestion and simplify maintenance Circuit designation labels above connectors and on cable tray ensure proper cable routing and identification Bay equipped with cable troughs, vertical wiring ducts, and equipment cable tie-down bars Zone 4 earthquake-rated rack with EIA mounting spacing

600 mm Products

D3C-0024T Front View

Ordering Information
Description Unloaded chassis Accommodates up to 24 modules 600 mm skeleton bay Accommodates up to 12 chassis Dimensions (HxWxD) 113 x 482.6 x 228.6 mm (4.4" x 19" x 9") 2200 x 600 x 475 mm (86.6" x 23.6" x 18.7") Catalog Number D3C-0024T IBR-D3C002

600 mm [23.6] 449.6 mm [17.7]

UPPER CABLE TROUGH

100571

45

RESERVED FOR MISCELLANEOUS APPLICATIONS

40

35

30

10/03

25

2200 mm [86.6]
20

15

10

LOWER CABLE TROUGH


5

IBR-D3C002 Front View

475 mm (18.7")

IBR-D3C002 Side View

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

117

Digital Distribution Frame System


Wall Mount Box
Features
Used as a demarcation point when NEs are supplied by the service provider and by the customer Separate locks on each door secure connections from unwanted access

600 mm Products

D3C-WBOX06 Front View

Ordering Information
Description Unloaded wall mount box Accommodates up to 6 modules Note: Modules are ordered separately Dimensions (HxWxD) 267 x 203 x 114 mm (10.5" x 8" x 4.5") Catalog Number D3C-WBOX06

Specifications
ELECTRICAL Insertion Loss: Return Loss: Monitor Loading Effect: Monitor Level: Isolation: Cross Talk: Phase Delay Pulse Template: MECHANICAL Retention Force: Retention Torque: ENVIRONMENTAL Thermal Shock: Moisture Resistance: Better than -.5 dB, 100 KHz to 100 MHz Better than -.8 dB, 100 MHz to 300 MHz Better than -20 dB, 100 KHz to 300 MHz < .4 dB change in insertion loss to 300 MHz 21.5 1.5 dB, 100 KHz to 300 MHz < -55 dB at 22.368 MHz < -55 dB at 22.368 MHz < 4 nanoseconds to 300 MHz Conform to CCITT Recomm. G.703

100571

7 lbs. minimum 4" per lbs. minimum

10/03

-40C to +60C operating -55C to +85C non-operating 0% to 95%

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

118

DSX-3 Patch Cords


DSX-3 Patch Cords (with RG59 type cable)
Ordering Information
Description DSX-3 patch cords Used to patch between DSX-3 jacks Midsize plugs With RG59 type cable Catalog Number PCH-MMXB-XXX

600 mm Products

Replace XXX with desired patch cord length (001 to 050 feet).

PCH-MMXB-003

Factory-Terminated Rear Cross-Connect Jumpers


Catalog Number Connector Interface Type on First End of Jumper B G XCC- ___ ___ X ___ - ___

Factory-terminated BNC connector Factory-terminated 16./5.6 connectors


XCC-BBXD-003 Connector(s) and tracer pin(s) factory-terminated on both ends.

Connector Interface Type on Second End of Jumper B G Factory-terminated BNC connector Factory-terminated 1.6/5.6 connectors XXX

100571

*Standard Jumper Lengths: 3', 6', 9', 12', 15', 18', 20', 25', 30', 35', 40', 45', 50' (.92, 1.83, 2.75, 3.66, 4.58, 5.49, 6.1, 7.63, 9.15, 10.68, 12.2, 13.73, 15.25 m) Ordering Example: Catalog number XCC-BBXD-015: 15' (4.58 m) dual cross-connect jumper using 735 type coaxial cable with tracer messenger wire, (2) BNC connectors and tracer pin factory-terminated on both ends of cable.

Jumper Length* Length in feet (001 thru 050)

Coaxial Cable Type C D Single 735 with tracer messenger wire (4J, 4U, 4H, 4M compatible) Dual 735 with tracer messenger wire

10/03

Factory-Terminated Patch Cords


Catalog Number Connector Interface Type on First End of Patch Cord B G PHC - ___ ___ X ___ - ___ Patch Cord Length* XXX Length in feet (001 thru 050)

Factory-terminated BNC connector Factory-terminated 16./5.6 connectors

Connector Interface Type on Second End of Patch Cord B G Factory-terminated BNC connector Factory-terminated 1.6/5.6 connectors

Coaxial Cable Type C D Single 735 with tracer messenger wire (4J, 4U, 4H, 4M compatible) Dual 735 with tracer messenger wire

*Standard Patch Cord Lengths: 3', 6', 9', 12', 15', 18', 20', 25', 30', 35', 40', 45', 50' (.92, 1.83, 2.75, 3.66, 4.58, 5.49, 6.1, 7.63, 9.15, 10.68, 12.2, 13.73, 15.25 m)

Ordering Example: Catalog number PHC-BBXD-015: 15' (4.58 m) dual cross-connect jumper using 735 type coaxial cable with (2) BNC connectors terminated on both ends of cable.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

119

DSX-3 Accessories
Coaxial Connectors
Ordering Information
Cable Dimensions Catalog Number Straight BNC Connectors BNC-3 BNC-7 BNC-2 BNC-1 BNC-4 Right Angle BNC Connectors BNC-RA-3 BNC-RA-7 BNC-RA-2 BNC-RA-1 BNC-RA-4 Straight TNC Connectors TNC-3 TNC-7 TNC-2 TNC-1 TNC-4 Cable Type Outer Jack Diameter Center Conductor Connector Crimp Sleeve Center Pin*

600 mm Products

735A 0222 RG59 734 728

0.127" 0.155" 0.241" 0.236" 0.305"

26 24 23 20 20

gauge gauge gauge gauge gauge

0.178" 0.197" 0.255" 0.255" 0.324"

0.042" 0.042" 0.042" 0.042" 0.042"

735A 0222 RG59 734 728

0.127" 0.155" 0.241" 0.236" 0.305"

26 24 23 20 20

gauge gauge gauge gauge gauge

0.178" 0.197" 0.255" 0.255" 0.324"

0.042" 0.042" 0.042" 0.042" 0.042"

735A 0222 RG59 734 728

0.127" 0.155" 0.241" 0.236" 0.305"

26 24 23 20 20

gauge gauge gauge gauge gauge

0.178" 0.197" 0.255" 0.255" 0.324"

0.042" 0.042" 0.042" 0.042" 0.042"

10/03

100571

*In addition to the .042" square pin crimp, all connectors listed above are compatible with a 12 point method of crimping.

BNC-3

BNC-RA-3

TNC-3

Tracer Pins
Ordering Information
Description Tracer pin and sleeve 1 each Tracer pin and sleeve 100 piece kit Catalog Number PGS-110005 PGS-110006

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

120

DSX-3 Accessories
Tool Kit
Ordering Information
Description Connection tool kit Includes: Crimp tool (WT-2) BNC crimp die set for 735, RG59 and 734 cables (WD-2) Stripping tool with cassette for 735/0222 cables (STC-13B) Stripping tool with cassette for RG59/734 cables (STC-12B) Cable termination tray (LCA-000009) Insertion/withdrawal tool for BNC connector (BT2000) Carrying case BNC-TOOL-1 Catalog Number BNC-TOOL-1

600 mm Products

Coaxial Tools
Ordering Information
Description Adjustable cable termination tray for 19" or 23" chassis Insertion/withdrawal tool BNC connector TNC connector Coaxial cable cutter Crimp tool Crimp die set for WT-2 tool 735, RG59 and 734 cables 0222 cable RG59, 734 and 728 cables Stripping tool with black cassette for BNC or TNC connector 735A/0222 cables RG59/734 cables 728 cables Replacement cassette (black) for BNC or TNC connector 735A/0222/RG59/734/728 cables Catalog Number LCA-000009 BT2000 TT1000 DSX-3 CCUT WT-2 WD-2 WD-3 WD-1 STC-13B STC-12B STC-11B CCS-BLK DSX-3 CCUT TT1000 BT2000 LCA-000009

10/03

100571

WT-2

STC-13B

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

121

2 Mbps DSX Front Cross-Connect Solutions


600 mm 2 Mbps DSX Product Family DSX Introduction
Digital signal cross-connect (DSX) products are used to connect one piece of digital telecommunications equipment to another. This simplifies equipment connections and provides a convenient test access point as well as a convenient location for rearranging and restoring circuits. Cross-connecting network elements of a DSX is a simple, efficient way of organizing a facility's digital telecommunications equipment. There are three basic areas in a DSX. The wire termination area for terminating the signal (wire) from a network element. The cross-connect area, used to connect the two DSXs that have terminated the signals from two digital network elements. And finally, the heart of the DSX, the jack. Each DSX jack provides an OUT, IN and MONITOR signal access point. The OUT and IN switching jacks provide direct access to the network element's input and output signals. These jacks provide a means of temporarily breaking the connection between DSX panels that are cross-connected together and allow access to the signals for test and patching operations. A MONITOR jack with high impedance bridge networking is connected to the OUT jack for nonintrusive access to the output signal of each network element. At 2.048 Mbps rate, DSX-1 panels connect network equipment such as office repeater bays, channel banks, multiplexers, digital switches, loop carriers, loop switches, radio, fiber optic systems, and other 2 Mbps equipment.

600 mm Products

Traditional DSX Application


Network Element A DSX
MON Tx OUT Rx IN OUT IN PERMANENT EQUIPMENT CABLE OUT IN X-IN X-OUT Typical DSX SemiPermanent Cross Connect Jumper X-OUT OUT IN X-IN PERMANENT EQUIPMENT CABLE LED Tracer Wire

DSX
MON
M O I

Network Element B

OUT IN

Tx OUT Rx IN

100571

Test Box

Test Box

10/03

Monitoring and testing with traditional DSX requires finding and going to two locations for complete circuit testing. It also requires access to both DSX sites and the time necessary to travel and setup test gear in two locations.

DSX Features and Benefits


OUT/IN jacks Fast and easy access to circuits for testing, monitoring and patching Bantam die-cast jacks Guarantees quality and reliability over time Flashing LEDs available in a variety of colors Provides easy circuit identification Multiple designs and configurations Design optimized for each application Coax and 120 Ohm connections provide the flexibility to connect 75 Ohm equipment to 120 Ohm equipment

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

122

2 Mbps DSX Front Cross-Connect Solutions


600 mm 2 Mbps DSX Product Family
The Products
The 600 mm skeleton bay is the basis of ADCs 2 Mbps DSX product offering. The fully-assembled bay meets the standard ETSI 600 mm wide x 2200 mm tall footprint. The fuse panel and all the necessary cable management are factory-installed in the bay making installation and ordering fast and easy. DSX panels are added in the field as needed. The 600 mm skeleton bay is compatible with all ADC 64-termination DSX panels. A total of 832 twisted pair or coaxial terminations fit in each bay.

600 mm Products

FlexDSX Panel

PxPlus Panel

100571

Loaded 600 mm Skeleton Bay

Empty 600 mm Skeleton Bay

DSX 64-Termination Panel

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

123

2 Mbps DSX Front Cross-Connect Solutions


Product Selection Guide
FlexDSX Panels
FlexDSX panels offer four-port jack access with dual monitor for applications where the cross-connect may be located far away or is inaccessible such as in collocation applications. The dual monitor port also allows for fast isolation of problems as both sides of the circuit can be accessed easily from one termination. The jacks are individually removable and the backplane terminations are removable in groups of four.

PxPlus Panels

600 mm Products

Ideal for applications requiring three-port jack access and true cost-deferment as equipment cables can be preterminated and jacks can be added as needed. If the chassis has more than 60% of its terminations turned up within one year, the fixed, non-modular DSX 64 panels may be a better choice for a high growth environment.

DSX 64-Termination Panels


Ideal for applications where individual circuit modularity is not required. This is a fixed, non-modular 64 termination panel with three-port jack access.

Feature/Need 64 terminations/panel (Balun & twisted pair) Mounts in IBF-RSC021 skeleton bay (832) 2 Mbps terminations per bay Tracer LED Ability to prewire backplane Oversized labels In-service patching and circuit rearrangement

FlexDSX X X X X X X X X X X X X

PxPlus X X X X X X X X X X

DSX 64 X X X X X X X X X

100571

Balun options (BNC & 1.6/5.6) Patching and monitoring capabilities Removable jacks Dual monitor (4 port jacks) Variety of backplanes and connector options to fit into 1 chassis

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

124

2 Mbps DSX Front Cross-Connect Solutions

ADC 600 mm Skeleton Bay for FlexDSX, PxPlus and DSX64 Panels
The 600 mm skeleton bay is designed for FlexDSX, PxPlus and DSX 64-termination panels. The fullyassembled bay meets the standard ETSI 600 mm wide x 2.2 meter tall footprint for easy office planning. Rack mounting will also accommodate standard 48.26 cm (19 inch) panels. Fuse panels and all the necessary cable management are factory-installed in the bay, making ordering and installation fast and easy. DSX panels are added in the field as needed. OUT (Tx) and IN (Rx) cable ways for equipment terminations support the use of either 120 Ohm twisted pair or 75 Ohm coaxial cable. The skeleton bay can be mounted on either concrete or raised floor.

600 mm Products

Extra rack space reserved for miscellaneous applications (such as cross aisle panels or monitor panels) or for additional DSX panels (up to [832] 2 Mbps terminations) High-density supports up to (12) 5.25-inch (13.34 cm) panels or (768) 2 Mbps terminations (120 Ohm or 75 Ohm) per bay Single part number simplifies ordering and installation

Panels mount over the rings no need for removal of rings during installation All metric hardware allows easy replacement for misplaced screws

Rings and troughs preprovisioned jumper management ensures existing wiring is not disturbed during expansion or maintenance

100571

Cable tie down bars on the rear of the bay eliminate the need for filler panels and end guards

10/03

600 mm 600 mm Empty Skeleton Bay

600 mm width aligns perfectly with raised floor tile dimensions and simplifies office engineering and planning

600 mm Skeleton Bay Front Jumper Rings (shown with panels installed)

Ordering Information
Description Skeleton bay front cross-connect Catalog Number IBF-RSC021

Note: Bays come fully-loaded with cable troughs, cable rings, fuse panel and grounding kits. The bay holds up to nine 7-inch (17.78cm) high modules.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

125

2 Mbps DSX Front Cross-Connect Solutions


FlexDSX Introduction
The FlexDSX platform from ADC embodies the ultimate flexibility in circuit access. The 4-port jack card provides dual monitor capability. Dual monitoring allows nonintrusive monitoring in both directions of a 2 Mbps signal from a single DSX location. Monitoring a circuit in both directions from a single DSX location will save time when troubleshooting the network because test gear isnt moved to a second DSX location to test the complete circuit. Dual monitoring also gives access to complete circuits when the other end of the cross-connection is not available, as in the situation where collocation of two carriers exists and the cross-connection between DSX provide the point of interconnection. FlexDSX products also provide flexibility in deploying your resources. The completely modular design allows you to deploy modules and chassis on an as-needed basis. By creating a lineup of skeleton bays and filling the bays with chassis and modules only as needed, you can defer capital expenses until the equipment is ready to create a revenue stream. In today's multinational, multiservice environment, FlexDSX products offer a variety of standard terminations. From wire-wrap to coax to RJ45 connectors, FlexDSX products offer the option to terminate 2 Mbps equipment from a single location.

600 mm Products
100571

Features
Conduct protocol testing for both OUT and IN transmission directions from one location saves time when testing a circuit Staggered jack alignment allows industry standard patch cords to be used side-by-side in high density products Jumper rings and rear cable bars are installed on the skeleton bay provides superior cable management OUT/IN equipment cable terminations on the backplane are modular in groups of four allows for multiple circuit count configurations (56, 64, 84) Works with twisted pair or coax cabling; choose wire-wrap, BNC or 1.6/5.6 interfaces flexibility to meet a variety of needs Coax and 120 Ohm connections provide the flexibility to connect 75 Ohm equipment to 120 Ohm equipment

FlexDSX Application
Network Element A FlexDSX
MON Tx OUT Rx IN OUT IN OUT IN X-IN MON PERMANENT EQUIPMENT CABLE Typical DSX SemiPermanent Cross Connect Jumper X-IN MON PERMANENT EQUIPMENT CABLE X-OUT X-OUT OUT IN LED Tracer Wire

FlexDSX
MON
M O I

Network Element B

10/03

OUT IN

Tx OUT Rx IN

Test Box

FlexDSX products provide the convenience and time-saving feature of testing and monitoring the signal in both directions from one location.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

126

2 Mbps DSX Front Cross-Connect Solutions


FlexDSX Panels Four-Port (Dual Monitor) Jack Access
FlexDSX panels are the only DSX panels in the industry that offer individual, removable jacks, removable OUT/IN equipment cable terminations, and four-port (bidirectional) test access capabilities. The four-port jack system consists of OUT and IN jacks for direct access to the network elements input and output signals, and DUAL MONITOR jacks for monitoring of the signal in both directions simultaneously at a single location. Dual monitors are especially beneficial for testing when the other side of the cross-connect is located far away, in another room, or is inaccessible (i.e., collocation).

600 mm Products

FlexDSX Front View Large labels provide clear documentation of circuits 64-terminations per panel (Balun and twisted pair) matches 2.048 Mbps equipment cabling breakouts Large front trough avoids cable build-up Staggered jacks allow industry standard patch cords to be used side-by-side

FlexDSX Rear View (1.6/5.6 Balun version shown) Chassis are configured with OUT/IN interfaces in groups of four for easy removal and minimal disturbance of adjacent circuits

Tracer LED eliminates manual tracing of circuits for faster circuit identification Individual removable jacks Four-port (dual monitor) jacks allow quick isolation of problems in larger applications where the cross-connect may be located far away or is inaccessible FlexDSX four-port jack card FlexDSX panel with individual jack card pulled out

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

127

2 Mbps DSX Front Cross-Connect Solutions


FlexDSX Panels Four-Port (Dual Monitor) Jack Access
Ordering Information
Description Fully-loaded, 64-circuit panel Wire-wrap cross-connects 5.25" (13.34 cm) high, 19" (48.26 cm), EIA/IEC mounting 120 Ohm wire-wrap equipment interface 120 Ohm wire-wrap equipment interface, rear dual performance monitor BNC Balun equipment interface 1.6/5.6 Balun equipment interface SMB RJ45 Shielded RJ45 7" (17.78 cm) high*, 19" (48.26 cm), EIA/IEC mounting BNC equipment interface 1.6/5.6 equipment interface *The IBF-RSC024 skeleton bay holds nine 7-inch (17.78 cm) high panels DFX-100001 DFX-100001-DPM DFX-210001 DFX-220001 DFX-230001 DFX-400001 DFX-500001 DFX-210001-DPM* DFX-220001-DPM* Catalog Number

600 mm Products
100571

Module and Card


4-Port Jack Card with 4-Pack Module

10/03

4-Pack Module with 1.6/5.6 connectors

4-Pack Module with wire-wrap connectors

4-Pack Module with BNC connectors

4-Port Jack Card

Ordering Information
Description FlexDSX 64-position empty chassis 19" (482.6mm) x 5.25" (133.35mm) (3RU) 4-pack modules Wire-wrap, front cross-connect, 120 Ohm BNC, front cross-connect, 75 Ohm 1.6/5.6, front cross-connect, 75 Ohm RJ45, front cross-connect, 120 Ohm Shielded RJ45, front cross-connect, 120 Ohm SMB, front cross-connect, 75 Ohm Circuit cards FlexDSX jack, odd FlexDSX jack, even Catalog Number DFX-9E0002 DFX-9E1000 DFX-9E2000 DFX-9E3000 DFX-9E4000 DFX-9E4000-S DFX-9E5000 DFX-1 DFX-2

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

128

2 Mbps Digital Cross-Connect System


All-Front-Access FlexDSX Panels
The all-front-access FlexDSX product family, designed for 2.048 Mbps cross-connect applications for the standard 600 mm footprint, provides 0.045" (1.14 mm) square wire-wrap pin interface options on both the cross-connect and equipment fields and is available with or without performance monitoring. Each chassis holds up to 16 four-circuit front access module packs. No internal wiring is required between modules and the chassis or between adjacent modules. Each of the 64 individual jack cards in a fully-populated chassis have four bantam-sized portsmonitor OUT, OUT, IN, and monitor IN, as well as a red flashing tracer lamp. Monitor network resistors provide 120 Ohm impedance.

600 mm Products

FlexDSX chassis without performance monitoring (Front View) Four-Pack Modules

100571

FlexDSX chassis with performance monitoring (Front View) Four-Pack Modules

10/03

Ordering Information
Description All-front-access FlexDSX panels Empty rack (holds 10 DFX-1F0001 chassis) Fully-loaded panel Empty chassis Four pack module All-front-access FlexDSX with performance monitoring Empty rack (holds 8 DFX-1F0001-DPM chassis) Fully-loaded panel Empty chassis Four pack module Catalog Number DFX-RSFA04 DFX-1F0001 DFX-9E0003 DFX-9F1000 DFX-RSFA03 DFX-1F0001-DPM DFX-9E0003-DPM DFX-9F1000-DPM

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

129

2 Mbps DSX Front Cross-Connect Solutions


PxPlus Panels Three-Port Individual Jack Modularity
The PxPlus panel was designed for 2 Mbps DSX cross-connect applications where individual jack modularity is required. The PxPlus system consists of a 64-circuit empty panel and individual three-port jack access cards that are sold separately. The empty panel can be loaded into the bay and precabled. When service is ready to be turned up, the PxPlus jack cards are installed into the panel providing for true cost deferment.

600 mm Products

PxPlus panel shown fully loaded with circuit cards Large removable labels provide easy documentation of circuits to help avoid mistakes while trouble shooting.

PxPlus panel shown empty without circuit cards Designed for individual jack modularity jacks are ordered separately and installed upon service turn-up.

Tracer LED eliminates manual tracing of circuits for faster circuit identification Backplane can be fully prewired upon installation allows circuit cards to be added as needed for true cost deferment 64 terminations per panel (Balun and twisted pair) matches equipment cabling breakouts

Three-port (single monitor) jack access allows easy circuit access for testing, patching and monitoring

10/03

100571

PxPlus Panel with individual jack card pulled out

PxPlus panel (rear view) (Wire-wrap version shown)

Ordering Information
Description 64-circuit empty chassis Wire-wrap equipment interface BNC Balun equipment interface Jack card Individual 120 Ohm PXP-A00006 PXP-532004 PXP-532003 Catalog Number

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

130

2 Mbps DSX Front Cross-Connect Solutions


DSX 64-Termination Three-Port Fixed Panel
Each panel supports 64 2 Mbps terminations and provides three-port jack access for monitoring, patching and testing. An LED provides easy identification of cross-connect cables by eliminating manual tracing of wires. The equipment (OUT/IN) cables are terminated on the rear of the chassis via wire-wrap and Balun options of 1.6/5.6 or BNC connectors. The cross-connects are terminated on the front via wire-wrap pins.

Features
64 terminations per panel (Balun and twisted pair) matches 2.048 Mbps equipment cabling breakouts All panels mount into the ADC 600 mm skeleton bay IBF-RSC021 one platform for all applications Tracer LED eliminates manual tracing of cross-connect wires for fast circuit identification Oversized labels for complete circuit identification In-service patching and circuit rearrangement allows circuit maintenance to be completed during business hours without downtime by using ADCs bridging office repeaters (Call your local ADC sales office for more information) Balun terminations increase density by converting 75 Ohm equipment cables to 120 Ohm for crossconnecting while still providing the flexibility of DSX jack access. Available in BNC and 1.6/5.6

600 mm Products

DSX 64-Termination Panel (Front View)

100571

Front wire-wrap cross-connect pins for easy circuit rearrangement Large removable labels provide easy documentation of circuits to help avoid mistakes while troubleshooting

DSX 64-Termination Panel (Rear View) (BNC Balun version shown) 64-terminations per panel (Balun and twisted pair) matches equipment cabling breakouts

One part number allows for easy ordering and installation Three-port (single monitor) jack access allows easy circuit access for testing, patching and monitoring Tracer LED eliminates manual tracing of circuits for faster circuit identification DSX 64-Termination Panel

10/03

Ordering Information
Description 64-termination panel 120 Ohm wire-wrap equipment interface BNC Balun to wire-wrap equipment interface 1.6/5.6 Balun to wire-wrap equipment interface D1M-1A2016 D1M-1A2015 D1M-1A2017 Catalog Number

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

131

2 Mbps Digital Cross-Connect System


Bay Hardware and Accessories End Guard
These 2.2 m high end guards provide protection and a finished appearance at the start and end of the lineup.
Ordering Information
Description 450 mm deep end guard Catalog Number RAC-EGK450* RAC-EGK600* RAC-EGK300*

600 mm Products

600 mm deep end guard 300 mm deep end guard * Each kit comes with two end guards

DSX Frame Doors


The door kit provides left and right doors for the front and rear of the DSX frame. Also included are top, front, and rear brackets for mounting of the doors to the frame.
Ordering Information
Description DSX frame door kit Catalog Number IBF-1ENCDOR

End Guard for Use with Door Enclosure Kit


This end guard kit is used in conjunction with the DSX frame doors used to enclose the frame. It also provides protection and a finished appearance to the start and end of the frame lineup.
Ordering Information
Description End guard for use with DSX frame door kit Catalog Number IBF-1ENCEG

10/03

100571

Filler Panel Kits


The filler panel kits add spacing between DSX frames. The kits come in 150 mm and 300 mm measurements.
Ordering Information
Description 150 mm filler panel kit 300 mm filler panel kit that includes upper and lower cable trough Catalog Number SFK-122150 SFK-122300

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

132

2 Mbps Digital Cross-Connect System


Bay Hardware and Accessories Rack Installation Kit
This rack installation kit comes with all the necessary hardware to install the DSX rack in a raised floor environment.
Ordering Information
Description Zone 2 raised floor mounting kit Concrete floor kit Catalog Number RAC-MX0615 RAC-MX0616

600 mm Products

Note: See installation guidelines for instructions on mounting the DSX Frame.

AC Outlet Kit
This AC outlet kit is a universal continental Europe outlet that mounts in the base of the frame.
Ordering Information
Description UK AC outlet kit Continental Europe AC outlet kit North American AC outlet kit Catalog Number AUX-AC0003 AUX-AC0004 AUX-AC0005

Cross Aisle Panels


Ordering Information
Description 128-circuit cross aisle panel 64-circuit cross aisle panel with trace LEDs Catalog Number AUX-200022 AUX-200064

100571

Alarm Panels
Ordering Information
Description 64-circuit all front access panel Catalog Number AUX-000040

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

133

2 Mbps Super High Density Solutions


DSX600 Bay
ADC introduces the 600 mm Super High Density Bay (SHD) product line. Quick to install, easy to manage and maintain, Super High Density Bays maximize the networks termination density, simplifies engineering and is designed to match any application. Perfectly. ADCs 600 mm Super High Density DSX ensuring transparent service evolution.

Features and Benefits


One part number ADCs Super High Density (SHD) Bay comes preassembled to the customers specification, eliminating multiple parts and lineup hardware. This reduces installation time, simplifies ordering, and helps generate revenue faster by turning up service sooner. Waterfall IN/OUT cabling Waterfall cabling increases lineup density, thereby saving valuable floor space and reducing cost by eliminating the need for bay spacers. 600 mm width The bays width aligns perfectly with raised floor tile dimensions, simplifying office engineering and planning. Integrated trouble-free cross-connect cable management Providing increased jumper capacity, ADCs patented cable management system eases operations and maintenance by reducing cross-connect jumper congestion. Expanded labeling space Decreases possibility of mistakes during troubleshooting as all circuits are clearly identified. 64-position panels Panel termination count matches digital switch and fiber optic multiplexer 2 Mbps signal groups for simplified network engineering. 1152 wire-wrap or 768 BNC terminations Industry's highest DSX density improves profitability by conserving valuable floor space. Helps providers realize more revenue and have more space for other revenue-generating network equipment. 192 cross aisle tie circuit Integrated cross aisle tie panels ensure ability to add new lineups without sacrificing overall termination density. Single or dual bantam monitor ports Streamlines installation, maintenance and troubleshooting. Supports traditional monitoring practices as well as monitoring on OUT (Tx) and IN (Rx) ports of the DSX. Overhead and raised floor cabling Provides flexibility for any installation criteria.

10/03

100571

600 mm Products

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

134

2 Mbps Super High Density Solutions


DSX600 Bay

600 mm Products

ADCs Super High Density Bay (SHD) comes preassembled to customer specification, eliminating multiple parts and lineup hardware. This reduces installation time, simplifies ordering and saves money. Waterfall cabling increases lineup density, thereby saving valuable floor space and reducing cost by eliminating the need for costly bay spacers.

100571

600 mm

600 mm

With its 600 mm width, ADCs SHD bay aligns perfectly with raised floor tile dimensions simplifying office engineering and planning. By providing increased jumper capacity (a), ADCs patented cable management system (b) eases operations and maintenance by reducing cross-connect jumper congestion. This makes removal of inactive jumpers easy.

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

135

2 Mbps Super High Density Solutions


DSX600 Bay
5 5
Labeling is critical to troubleshooting efforts. ADCs SHD Bay allows technicians to clearly identify each circuit by providing expanded labeling space to improve network documentation and decrease the potential for mistakes while troubleshooting.

600 mm Products

100571

The SHD Bay utilizes 64-termination panels to match digital switch and fiber optic multiplexer two megabit signal groups, simplifying network engineering. With (1152) 2 Mbps terminations and 192 cross aisle terminations, ADCs SHD Bay provides the industry's highest DSX density available, saving money by conserving valuable floor space. In situations where 75 Ohm terminations are required, ADC provides a 768 termination bay which fits in the same lineup as the 120 Ohm bay and maintains the advantage of ADCs patented cross-connect jumper management.

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

136

2 Mbps Super High Density Solutions


DSX600 Bay
Ordering Information
Description 2.13 m 1152 2 Mbps terminations 192 cross aisle tie circuits Wire-wrap OUT/IN interface Wire-wrap cross-connect interface Designed for below floor cabling 2.13 m x 600 mm x 457 mm SHD-0323 Dimensions (HxWxD) Catalog Number

600 mm Products

768 2 Mbps terminations 75 Ohm BNC OUT/IN interface Wire-wrap cross-connect interface Designed for below floor cabling Super High Density Bay end guard 2.2 m 1152 2 Mbps terminations 64 cross aisle tie circuits Dual monitor panels 32 interbay circuits Designed for below floor cabling 1152 2 Mbps terminations 192 cross aisle tie circuits Wire-wrap OUT/IN interface Wire-wrap cross-connect interface Designed for overhead cabling 1344 2 Mbps terminations 120 Ohm BNC OUT/IN interface Wire-wrap cross-connect interface Designed for below floor cabling Super High Density Bay end guard Super High Density Bay raised floor installation kit (for 600 mm floors) Super High Density Bay raised floor installation kit (for 850 mm floors) Concrete floor installation kit

2.13 m x 600 mm x 457 mm

SHD-0424

SHD-0007

2.2 m x 600 mm x 457 mm

SHD-W-0001

2.2 m x 600 mm x 457 mm

SHD-0512

2.2 m x 600 mm x 457 mm

SHD-0051

100571

SHD-W-0005 SHD-HR-28 SHD-HR-55 RINST-FLR

10/03

Super High Density Bay Front View

Super High Density Bay Rear View

(Note: This application shows overhead cabling. This configuration is available upon request.)

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

137

2 Mbps Super High Density Solutions


FlexDSXSuper High Density Bay Introduction
ADCs FlexDSX Super High Density Bay offers greater termination density as well as built-in, trouble-free cable management for flexible network planning, installation and maintenance. ADCs FlexDSX Super High Density Bay design is unmatched in the marketplace. ADCs vertical IN/OUT terminal blocks with extra cabling space and cable management fanning strips provide 50 percent more cabling space than traditional high-density bays. Simultaneously, it provides increased jumper capacity to simplify cross-connect wire management for easy operation and maintenance. The FlexDSX Super High Density design incorporates a recessed vertical wireway for cross-connect cabling and up to seven horizontal cross-connect jumper wireways instead of the standard two wireways. Vertical and horizontal wireways are on separate planes to avoid congestion and pile-up at intersections. The FlexDSX Super High Density Bay enables service providers to realize additional cost savings by conserving valuable floor space. The bay provides more than 30 percent floor space savings, while doubling the density and provides dual monitoring with ADCs reliable FlexDSX jack technology.

600 mm Products
100571 10/03

Description
The FlexDSX Super High Density Bay achieves greater density in a 7-foot height x 26-inch width x 18-inch depth, accommodating up to 1512 (7') usable DSX jack terminations. ADCs flexible ordering guide allows bay designs in 64 or 84 jacks per panel. This eliminates jack waste or complications in circuit management administration.

Provides clear identification of each circuit by offering expanded labeling space improving network documentation and decreasing potential mistakes while troubleshooting Colored cross-connect labels allow for easy determination of circuit terminations

Flashing LED and Dual monitoring

Blocks design provides better cable management and more space for cables Cable entry is allowed on both sides of block

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

138

2 Mbps Super High Density Solutions


FlexDSXSuper High Density Bay Description
1512 jacks per seven-foot bay uses an efficient jack count of 84 jacks per panel. Dual monitoring of the out and in ports, panel termination count matches digital switching broadband equipment for simplified network engineering. Consists of 18 panels of 84 jacks in a single plane. More than 30 percent floor space savings the industrys highest DSX density improves profitability by conserving valuable floor space. Service providers can realize more revenue and more space for other revenue generating network equipment. Incorporating vertical IN/OUT terminal blocks with extra cabling space and cable management strips provide 50 percent more cabling space than traditional high-density bays. Increased lineup density saves valuable floor space and reduces costs by eliminating the need for bay spacers. Dual hinged doors with designation labels on both sides provide double the designation space. Adhesive backed labels guarantee the identification designations will always be available. The expanded label space minimizes the possibility of mistakes during trouble shooting as all circuits are clearly identified. Built-in trouble-free cross-connect cable management provides increased jumper capacity. ADCs cable management system eases operations and maintenance by reducing crossconnect jumper congestion and pileup. Tie pair terminal blocks (2) 80 circuits wired point-to-point to tie pair blocks in the rear cross-connect field by ADC. Built-in aisle tie panels ensure ability to grow new lineups without sacrificing overall termination density. The rear cross-connect high density design allows for all jack maintenance activities to remain at an arms length. Guarantees a worry-free maintenance environment with over 40 years of proven jack quality and reliability and a lifetime warranty. All components of the bay are made by ADC, ensuring quality from beginning to end.
Ordering Information
Description 7' concentration bay, overhead cabling 7' maintenance bay, overhead cabling 7' maintenance bay, raised Floor cabling 7' concentration bay, raised Floor cabling 2.2m concentration bay, overhead cabling 2.2m maintenance bay, overhead cabling Jack Position 84 84 84 84 64 64 # of # of Cross Terminations Aisle Circuits 1512 1512 1260 1260 1152 960 160 160 160 160 160 160 Catalog Number DFX-SHD001 DFX-SHD002 DFX-SHD003 DFX-SHD004 DFX-SHD005 DFX-SHD006 Super High Density Bay

10/03

100571

600 mm Products

*Overhead cabling denotes the cable enters the top of the bay and the equipment termination blocks are at the top of the bay. Raised floor cabling denotes the cable enters from the raised floor into the bottom of the bay and the equipment blocks are at the bottom of the bay.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

139

2 Mbps Super High Density Solutions


FlexDSX Super High Density Bay Accessories
Ordering Information
Description AC outlet kit (FlexDSX Super High Density Bays accept outlet kits in front only, North American) End guards 7' height x 18.75" width 2.2 m height x 18" width, 600mm rack SHD Installation kits 7' to 9' extension rack 7' to 11.5' extension rack Installation kit, raised floor Installation kit, concrete floor, overhead cabling Installation kit, raised floor, metric SHD-HR-43N SHD-HR-44N SHD-HR-91 RINST-FLR SHD-HR-93 Catalog Number ACOK-PWNB

10/03

100571

600 mm Products

SHD-HR-85 SHD-HR-92

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

140

2 Mbps Super High Density Solutions


Accessories Bantam Patch Cords
Ordering Information
Description Three conductor* Single 1' (.3 m) 1.5' (.46 m) 2' (.61 m) 2.5' (.76 m) 3' (.91 m) 4' (1.22 m) 5' (1.52 m) 6' (1.83 m) 8' (2.44 m) 10' (3.05 m) 12' (3.66 m) 15' (4.57 m) 20' (6.1 m) 25' (7.62 m) 30' (9.15 m) 50' (15.24 m) Dual* 1' (.3 m) 2' (.61 m) 2.5' (.76 m) 3' (.91 m) 4' (1.22 m) 5' (1.52 m) 6' (1.83 m) 8' (2.44 m) 10' (3.05 m) 12' (2.66 m) 14' (4.27 m) 20' (6.1 m) 25' (7.62 m) 30' (9.15 m) 35' (10.68 m) 45' (13.73 m) Patch cord kit International patch cords kit International patch cords kit, nickel-plated ACK-INTL ACK-INTL-N PJ712 PJ713 PJ714 PJ715 PJ716 PJ718 PJ720 PJ722 PJ1208 PJ1210 PJ1212 PJ1415 PJ1420 PJ1425 PJ1430 PJ1450 PJ762 PJ764 PJ765 PJ766 PJ768 PJ770 PJ772 PJ1308 PJ1310 PJ1312 PJ1514 PJ1520 PJ1525 PJ1530 PJ1535 PJ1545 Catalog Number

600 mm Products

PJ768 Three-Conductor Dual Patch Cord

100571

PJ718 Three-Conductor Single Patch Cord

10/03

* For nickel plated patch cords, add the suffix N. For plenum-rated fire retardant patch cords, add the suffix PL.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

141

2 Mbps Super High Density Solutions


Accessories Tools and Tool Kits
Ordering Information
Description Manual wire-wrap kit includes: Manual wire-wrap kit 22-24 AWG wire-wrap bit sleeve 24-26 AWG wire-wrap bit sleeve 22-24 AWG wire-wrap bit 26 AWG wire-wrap bit Mannual wire-cutting/stripping tool Manual unwrapping tool (screw driver tool) Manual unwrapping tool (soft, ergonomic handle) Unwrapping sleeve for use with AUX-0X0381 Electric 220 wire-wrap gun 22-24 AWG bit (0.64 - 0.51mm) 22-24 AWG sleeve (0.64 - 0.51mm) Catalog Number AUX-0X0165

600 mm Products

AUX-0X0803 AUX-0X0802 AUX-0X0381 AUX-0X0383 AUX-0X0466 AUX-0X0467 AUX-0X0468

Cross-Connect Wire
Ordering Information
Description Cross-connect Cross-connect Cross-connect Cross-connect wire, wire, wire, wire, 500-foot roll (150 m) 1000-foot roll (300 m) 1500-foot roll (450 m) 2000-foot roll (600 m) Catalog Number DSX-CCW/500 DSX-CCW/1000 DSX-CCW/1500 DSX-CCW/2000

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

142

Impedance Matching Panel


To keep pace with fast-changing technology and the need for excellent customer service, networks need to be completely flexible yet reliable. To enhance this flexibility, the impedance matching panel allows twisted pair cabling and coaxial cabling to coexist within a bay or bay lineups. A conversion must take place to transfer the signal reliably from one type of media to another. The 75/120 Ohm balun changes the impedance of a transmission line from a 75 Ohm unbalanced coaxial connection to 120 Ohm balanced twisted pair.

Application

600 mm Products

The impedance matching panel ensures digital signal reliability during the conversion from 75 Ohms to 120 Ohms. This panel is ideal for central office and collocation facilities where original equipment manufacturer (OEM) product interface incompatibilities frequently occur.

Conversion Panel Conversion Panel Conversion Panel Conversion Panel

Network Element A Twisted Pair Cable 120 Ohms

Conversion Panel Conversion Panel Conversion Panel Conversion Panel

Network Element B Coax Cable 75 Ohms

Impedance Matching Bay in Network

100571

Features and Benefits


Panels available with 8-, 16-, 24-, or 32-circuits Easily matches existing network equipment circuit counts Multiple connector interface type and location options Variety of configurations available to complement existing network designs Preinstalled cable management bars Reduces cable congestion and simplifies maintenance Cable management rings with labeling Ensures proper cable routing and circuit identification Reversible mounting brackets Each panel fits into 19-, 23-inch (48.3 or 58.4 cm) or 600 mm racks, or can be wall mounted

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

143

Impedance Matching Panel


Specifications
PHYSICAL Agency Certifications: Panel Dimension: Rack Mounting Width: Housing Material: Housing Finish: ELECTRICAL Insertion Loss: CE, CSA, UL See Dimension Chart 600 mm, 19", 23" Cold-rolled 14-gauge steel Powder-coated paint, putty white <.15 dB from 52 kHz to 5 MHz; <.2 dB from 5.1 MHz to 10 MHz <.22 dB from 10.1 MHz to 15 MHz; <.25 dB from 15.1 MHz to 20 MHz 1.024 MHz, -30 dB minimum; 20.0 MHz, -1.9 dB maximum 1000 Megaohms

600 mm Products

Return Loss: Insulation Resistance: ENVIRONMENTAL Thermal Shock: Humidity: Flammability:

-40C to +65C operating -55C to +85C non-operating 0% to 95%, non-condensing UL-94-VO Dimensions (HxWxD)

Number of Circuits 8-circuit 16-circuit 24-circuit 32-circuit

Total-Front-Access 3.47" x 19" x 2.5" (88.1 x 482.6 x 63.5 mm) 3.47" x 19" x 2.5" (88.1 x 482.6 x 63.5 mm) 5.22" x 19" x 2.5" (132.6 x 482.6 x 63.5 mm) 5.22" x 19" x 2.5" (132.6 x 482.6 x 63.5 mm)

Front/Rear Access 1.72" x 19" x 4" (43.7 x 482.6 x 101.6 mm) 1.72" x 19" x 4" (43.7 x 482.6 x 101.6 mm) 3.47" x 19" x 4" (88.1 x 482.6 x 101.6 mm) 3.47" x 19" x 4" (88.1 x 482.6 x 101.6 mm)

100571

Total-Front-Access Panels
3.47" (88.1 mm) 19.0" (482.6 mm) 3.0" (76.2 mm)

10/03

16-Circuit Panel

Front View 16-Circuit Panel BAL-AFAF-16

Front/Rear Access Panels


3.47" (88.1 mm) 19.0" (482.6 mm) 3.0" (76.2 mm)

32-Circuit (Front View)

Front View

32-Circuit (Rear View)

Rear View 32-Circuit Panel BAL-AFAR-32

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

144

Impedance Matching Panel


Catalog Number BAL - __ F __ __ - __ Balun Interface Type A BNC B 1.6/5.6 C Type 43* D 1.0/2.3* Number of Circuits 08 8-circuits** 16 16-circuits 24 24-circuits 32 32-circuits** Twisted Pair Interface Location F Front R Rear

600 mm Products

Balun Interface Location F Front Twisted Pair Interface Type A Wire-wrap B Punch down (QCP) C 64-pin receptacle connectors D 64-pin plug connectors

* Minimum order required for these connectors ** See dimension chart for panel heights

Ordering Information
Description Cable management accessories are ordered by panel height or bay width Cable management rings EIA bay kit includes two rings per kit and identification labels 1.72" (4.37 cm) high panel 3.47" (8.81 cm) high panel 5.22" (13.26 cm) high panel 600 mm bay kit includes two rings per kit and identification labels 1.72" (4.37 cm) high panel 3.47" (8.81 cm) high panel 5.22" (13.26 cm) high panel Cable support bar kit Cable support bar for front and rear access panels 19" wide rack mount 23" wide rack mount 600 mm rack mount Total front access mounting bracket kit Kit includes two brackets for mounting total front-access panels into 23" EIA or WECO racks 3.47" (8.81 cm) high panel 5.22" (13.26 cm) high panel 600 mm mounting bracket kit* Kit includes two brackets for mounting panel in bay 1.72" (4.37 cm) high panel 3.47" (8.81 cm) high panel 5.22" (13.26 cm) high panel Catalog Number

100571

AUX-0X0925 AUX-0X0926 AUX-0X0927

AUX-0X0928 AUX-0X0929 AUX-0X0930

10/03

AUX-0X0917 AUX-0X0918 AUX-0X0919

AUX-0X0934 AUX-0X0935 *Reversible mounting brackets are included with 19" panel except for total-front-access panels

AUX-0X0933 AUX-0X0915 AUX-0X0916

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

145

BroadWire ETSI Series


High-Density ADSL Splitter

600 mm Products

BroadWire 240 ETSI Series

BroadWire 120 ETSI Series

Features
High-density splitter platform manages 120 or 240 circuits per chassis Front-facing platform integrates in standard WECO/EIA 19-inch equipment racks or ETSI cabinet Holds CE Mark and UL 1950 certification, optimized for international deployment ADSL over POTS (ANSI T1.413), ADSL over ISDN (2B1Q or 4B3T), combination ADSL over ISDN over POTS, ETSI TR 101 728, ETSI TS 101 388 and custom billing tone/network impedance filters

100571

The BroadWire ETSI Series splitters are ETSI-compatible splitter platforms, supporting up to 120 or 240 circuits in a compact footprint. The BroadWire ETSI Series splitters enable service providers to broaden the use of existing copper infrastructure, providing high-speed ADSL and telephony services over a single twisted pair of copper wires. The BroadWire ETSI Series also supports ADSL over ISDN splitting with a custom filter design for 2B1Q, 4B3T, and other line encoding protocols. Effective ADSL deployment challenges service providers to maximize valuable floor space and maintain network integrity. High circuit density and sound cable management are vital, as is the ability to accommodate varying voice and data frequency specifications. A patent-pending cable management design and high circuit density make the BroadWire line of splitters the first in the industry to fully satisfy these requirements, preparing service providers for equipment co-location mandated by industry deregulation.

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

146

BroadWire ETSI Series


Applications

Central Exchange Subscriber


DSLAM

CLEC

ADSL modem

600 mm Products

BroadWire

MDF

BroadWire

Data frequency band 30 KHz+ Telephony frequency band 4 KHz

Class 5 Voice Switch

The BroadWire ETSI Series splitters can be deployed in the common area of the central exchange to provide data-only access to the CLEC technician, while still offering complete subscriber line access to the incumbent carrier.

100571

Central Exchange Subscriber


DSLAM
ADSL modem

10/03

Colocation
BroadWire

MDF BroadWire

Data frequency band 30 KHz+ Telephony frequency band 4 KHz

Class 5 Voice Switch

The BroadWire ETSI Series splitters can also be deployed inside the colocation area to offer full line access to the technician, while isolating and protecting the DSLAM equipment.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

147

BroadWire ETSI Series


Configurations
The BroadWire ETSI Series is a modular system that enables service providers to add splitter cards as the network expands. The BroadWire ETSI Series chassis can be populated with as few as one, and as many as ten (for the 240 ETSI Series), or five (for the 120 ETSI Series), 24-port splitter cards. The cards can be inserted and removed without affecting lifeline telephony service. The chassis can be installed with 120/240 telephony or ISDN lines connected to the chassis, regardless of whether or not every line has immediate need for ADSL service. A front-facing chassis, the BroadWire ETSI Series can be positioned against a wall to minimize the rack footprint. The chassis is front-cabled and requires no access from the rear of the chassis. Reversible rack mounting brackets are included, so that the BroadWire ETSI Series can be easily installed in ETSI racks.

600 mm Products
10/03 100571

Each chassis is ETSI rack mountable with center mounting brackets. Chassis are covered in the front and back. Nothing, including cables and connectors, will protrude into the maintenance aisle in a normal operating configuration. Cables exit from the front. Equipment is convection cooled. Smaller BroadWire chassis are available to support installations in campuses, multidwelling units or small, remote central offices. POTS and ISDN cards can be mixed in the same chassis to serve mixed applications. Bypass card available to support DSLAM to line side continuity for alternate DSL services.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

148

BroadWire ETSI Series


Specifications BroadWire 240 ETSI Series
PHYSICAL Dimensions (HxWxD): Weight Empty Chassis: Fully-Loaded Chassis: Mounting: Connector Access: Chassis Capacity: Splitter Card Capacity: 15.72" x 17.37" x 10.62" (399.29 x 441.20 x 270.0 mm) 43 lbs. (19.5 kg) 73 lbs. (33.1 kg) WECO/EIA rack-mountable, ETSI cabinet All-front-access chassis 240 circuits per chassis Each card contains 24 splitters. Ten cards can be installed in a chassis, for a maximum of 240 splitters per chassis. CE Mark, UL 1950 ADSL over POTS (ANSI T1.413), ADSL over ISDN (2B1Q or 4B3T), combination ADSL over ISDN over POTS, ETSI TR 101 728, ETSI TS 101 388 and custom billing tone/network impedance filters 50-pin (25 pair) RJ21 input from MDF 50-pin (25 pair) RJ21 POTS back to MDF Make-before-break connectors used for voice signal 50-pin (25 pair) RJ21 Loop connectors are arranged so that removing line cards does not disturb or require the removal of loop cables. Connectors are secured to prevent unintentional disconnection under strain, chafing or accidents. Empty card slots can be prewired for later use providing lifeline POTS service via make-before-break connectors incorporated in the chassis design. -40C to +70C 5% to 90% relative humidity -40C to +70C 5% to 95% relative humidity None

600 mm Products
100571 10/03

Agency Certifications: ADSL Splitter Filters:

CONNECTIONS Line In: POTS and ISDN Out: DSLAM Connection:

Lifeline POTS and ISDN: ENVIRONMENTAL Operating: Non-Operating: Power:

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

149

BroadWire ETSI Series


Specifications BroadWire 120 ETSI Series
PHYSICAL Dimensions (HxWxD): Weight Empty Chassis: Fully-Loaded Chassis: Mounting: Connector Access: Chassis Capacity: Splitter Card Capacity: 8.7" x 17.4" x 10.6" (22.1 x 44.2 x 26.9 cm) 15.1 lbs. (6.85 kg) 31.3 lbs. (14.2 kg) WECO/EIA rack-mountable, ETSI cabinet All-front-access chassis 120 circuits per chassis Each card contains 24 splitters. Five cards can be installed in a chassis, for a maximum of 120 splitters per chassis. CE Mark, UL 1950 ADSL over POTS (ANSI T1.413), ADSL over ISDN (2B1Q or 4B3T), combination ADSL over ISDN over POTS, ETSI TR 101 728, ETSI TS 101 388 and custom billing tone/network impedance filters 50-pin (25 pair) RJ21 input from MDF 50-pin (25 pair) RJ21 POTS back to MDF Make-before-break connectors used for voice signal 50-pin (25 pair) RJ21 Loop connectors are arranged so that removing line cards does not disturb or require the removal of loop cables. Connectors are secured to prevent unintentional disconnection under strain, chafing or accidents. Empty card slots can be prewired for later use providing lifeline POTS service via make-before-break connectors incorporated in the chassis design. -40C to +70C 5% to 90% relative humidity -40C to +70C 5% to 95% relative humidity None

600 mm Products
100571 10/03

Agency Certifications: ADSL Splitter Filters:

CONNECTIONS Line In: POTS and ISDN Out: DSLAM Connection:

Lifeline POTS and ISDN: ENVIRONMENTAL Operating: Non-Operating: Power:

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

150

BroadWire ETSI Series


Specifications T1.413 Compliant ADSL/POTS Splitter Card
ELECTRICAL Impedance: Insertion Loss: 900 Ohm, 5% (ZTc) <1.00 dB, Short Loop, 1.004 kHz, ZTc = 900, ZTr = 600 <0.75 dB, Long Loop, 1.004 kHz, ZTc = 900, ZTr = 600 65 dB at 30 kHz (typical, 600 Ohm term.) 55 dB at >300 kHz (maximum, 600 Ohm term.) <0.75 dB 8 kHz (typical) 70 Sec maximum (0.3 - 3900 Hz) None 12.5 Ohm maximum per path >8 dB ERL, >5 dB SRL-L, >5 dB SRL-H, short and long loops >2 dB SRL-H, short and long loop, single frequency DC to 8 MHz 100 mA DC >58 dB, 200 - 1 kHz, straight line level decreasing to 53 dB at 3 kHz, 25 mA DC bias current 83 nF, nominal 0 - 105 V 40 - 150 Vrms (at any frequency from 15 - 25 Hz) Fail-safe per UL 1950

600 mm Products
100571

Attenuation Distortion: POTS -3 dB Corner Frequency: Envelope Delay Distortion: Power Requirements: POTS Path Resistance: Voiceband Return Loss: Operating Bandwidth: POTS Loop Current: Longitudinal Balance: POTS Tip to Ring Capacitance: POTS Tip to Ring DC Voltage: POTS Ringing Signal: Power Cross:

ETSI ADSL/POTS (up to 16 kHz Billing Tone) Splitter Card


ELECTRICAL Impedance: Insertion Loss: Complex, 270 Ohm + (750 Ohm || 150 nF) 1.0 dB at 1 kHz (typical, complex term.) 2.0 dB at 4 kHz (typical, complex term.) <4.5 dB at 16 kHz (typical, 200 Ohm term.) >57.5 dB at 30 kHz (typical, complex term.) <0.75 dB 70 Sec maximum (0.3 - 3900 Hz) None 12.5 Ohm maximum per path >13 dB (per ETSI TR 101 728) DC to 8 MHz 100 mA DC >58 dB (minimum) 0 - 105 V 40 - 150 Vrms (at any frequency from 15 - 25 Hz) Fail-safe per UL 1950

Attenuation Distortion: Envelope Delay Distortion: Power Requirements: POTS Path Resistance: Passband Return Loss: Operating Bandwidth: POTS Loop Current: Longitudinal Balance: POTS Tip to Ring DC Voltage: POTS Ringing Signal: Power Cross:

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

151

BroadWire ETSI Series


Specifications 4B3T ADSL/ISDN Splitter Card
ELECTRICAL Impedance: Insertion Loss: ISDN Band Attenuation Distortion: ISDN -3 dB Corner Frequency: Envelope Delay Distortion: Power Requirements: POTS Path Resistance: Passband Return Loss: Operating Bandwidth: POTS Loop Current: Longitudinal Balance: Power Cross: 150 Ohm 5% (typical), differential 1.50 dB at f <80 kHz 70.0 dB at f >138 kHz <1.0 dB 95 kHz (typical) 20 Sec maximum (0.3 - 95,000 Hz) None 12.5 Ohm maximum per path >14 dB at f <80 kHz DC to 8 MHz 100 mA >55 dB Fail-safe per UL 1950

600 mm Products

Combination ADSL/ISDN/POTS Splitter Card


ELECTRICAL Impedance ISDN: POTS: Insertion Loss: 150 Ohm 220 Ohm + (820 Ohm || 115 nF) <2 dB at f 60 kHz <2.5 dB at f 80 kHz >50 dB at 200 kHz f 1.1 MHz <1.0 dB >80 kHz (typical) 20 Sec nominal (0.3 - 95,000 Hz) None 12.5 Ohm maximum per path >14 dB at f 80 kHz DC to 8 MHz 100 mA >55 dB Fail-safe per UL 1950

10/03

ISDN Band Attenuation Distortion: ISDN -3 dB Corner Frequency: Envelope Delay Distortion: Power Requirements: POTS Path Resistance: Passband Return Loss: Operating Bandwidth: POTS Loop Current: Longitudinal Balance: Power Cross:

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

152

BroadWire ETSI Series


Specifications 2B1Q ADSL/ISDN Splitter Card
ELECTRICAL Impedance: Insertion Loss: ISDN Band Attenuation Distortion: ISDN -3 dB Corner Frequency: Envelope Delay Distortion: Power Requirements: POTS Path Resistance: Passband Return Loss: Operating Bandwidth: POTS Loop Current: Longitudinal Balance: Power Cross: ENVIRONMENTAL Operating: Non-Operating: 135 Ohm 5% (typical), differential 1.50 dB at f 80 kHz 70.0 dB at f 138 kHz <1.0 dB 95 kHz (typical) 20 Sec maximum (0.3 - 95,000 Hz) None 12.5 Ohm maximum per path >14 dB at f 80 kHz DC to 8 MHz 100 mA >55 dB Fail-safe per UL 1950 -40C to +70C 5% to 90% relative humidity -40C to +70C 5% to 95% relative humidity

600 mm Products

Ordering Information
Description Chassis Catalog Number

100571

BroadWire 240 ETSI Chassis BroadWire 120 ETSI Chassis Cards BroadWire 24-port card T1.413 BroadWire 24-port card ETSI ADSL/POTS (up to 16 kHz billing tone) BroadWire 24-port card 4B3T BroadWire 24-port card Combination ADSL/ISDN/POTS BroadWire 24-port card 2B1Q Bypass card

IPC-CEXXXXX-0101 IPC-CEXXXXX-0052 IPC-RMT14DM-V242 IPC-RMETSDE-V242 IPC-RM4B3DX-V242 IPC-RMGERDX-V242 IPC-RM2B1DX-V242 IPC-RMBYPXX-0242

10/03

Note: Single-port CPE splitters available. Please contact your ADC sales representative.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

153

BroadWire 24

High Density ADSL Splitters

600 mm Products

Features
High-density splitter platform manages up to 24 circuits per chassis Rear-cabled and front-cabled platforms available Chassis integrate into standard EIA/WECO/ETSI equipment racks or cabinets NEBS Level 3, Type 1 and UL 1950 certified for North American deployment Holds CE Mark for international deployment POTS and ISDN filter designs available

ADCs BroadWire 24 ADSL splitter separates voice and data frequency bands enabling subscribers to receive voice and high-speed data services simultaneously over a single, twisted-copper pair. The BroadWire 24 supports up to 24 circuits, ideal for MDU/MTU/MHU deployment. The filters are designed to accommodate country-specific billing tone, complex impedance, and cable plant specifications. Effective ADSL deployment challenges service providers to maximize valuable floor space and maintain network integrity. High circuit density and sound cable management are vital, as is the ability to accommodate varying voice and data frequency specifications. A patent-pending backplane design and high circuit density make the BroadWire line of splitters the first in the industry to fully satisfy these requirements, preparing service providers for remote equipment deployment and line sharing mandated by industry deregulation.

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

154

BroadWire 24
Applications

600 mm Products

The BroadWire 24 splitter can be deployed in MDU/MTU/MHU environments enabling ADSL deployment to take place outside of central exchanges.

10/03

100571

The BroadWire 24 splitter can also be deployed within digital loop carriers (DLCs) enabling ADSL deployment to extend past previous distance limitations.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

155

BroadWire 24 ETSI Chassis


For Worldwide Deployment

The BroadWire 24 ETSI Chassis is optimized for worldwide deployment. It holds the CE Mark and complies with UL1950 standards. The chassis can be wall-mounted or placed in standard ETSI racks or cabinets, as well as 19" EIA/WECO racks. The chassis is designed for front cabling and card access.

600 mm Products

The chassis supports one 24-port splitter card. Make-before-break connectors allow the card to be inserted and removed without interrupting lifeline telephony service. A passive device, the chassis supports lifeline telephony service even in the event of a power outage.

Specifications
PHYSICAL Dimensions Height: Width: Depth: Weight Empty Chassis: Fully-Loaded Chassis: Mounting: Connector Access: Chassis Capacity: Splitter Card Capacity: ADSL Splitter Filters: 1.97" (50 mm) 17.2" (437 mm) 10.9" (277 mm) 7.0 lbs. (4.1 kg) 12.1 lbs. (5.5 kg) 19" EIA/WECO rack, ETSI rack or cabinet, or wall mountable All front-access chassis 24 circuits per chassis One 24-port splitter card T1.413 ITU G6.992.1 or 6.992.2 Complex impedance Complex impedance with 12 KHz billing tone Complex impedance with 16 KHz billing tone 2BIQ ISDN 4B3T ISDN (UK and German POTS filters under development) CE Mark; UL 1950

100571

Agency Certifications: CONNECTIONS Line In: POTS and ISDN Out: DSLAM Connection:

Lifeline POTS and ISDN: ENVIRONMENTAL Operating: Non-Operating: Power:

50-pin (25 pair) receptacle input from MDF 50-pin (25 pair) receptacle back to MDF Make-before-break connectors used for voice signal 50-pin (25 pair) RJ21 Loop connectors are arranged so that removing line cards does not disturb or require the removal of loop cables. Connectors are secured to prevent unintentional disconnection under strain, chafing, or accidents. The chassis can be pre-wired for later use providing lifeline POTS service via make-before-break connectors incorporated in the chassis design. -40C to +70C 5-90% relative humidity -40C to +70C 5-95% relative humidity None

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

156

BroadWire 24 Front Access Chassis


For North American Deployment

The BroadWire 24 Front Access Chassis is optimized for North American deployment. It complies with NEBS Level 3 and UL1950 standards and can be wall-mounted or mounted in standard EIA/WECO racks. The chassis is designed for front cabling within a single unit (1.75") of rack space.

600 mm Products

The chassis supports one 24-port splitter card. Make-before-break connectors allow the card to be inserted and removed without interrupting lifeline telephony service. A passive device, the chassis supports lifeline telephony service even in the event of a power outage.

Specifications
PHYSICAL Dimensions Height: Width: Depth: Weight Empty Chassis: Fully-Loaded Chassis: Mounting: Connector Access: Chassis Capacity: Splitter Card Capacity: ADSL Splitter Filters: Agency Certifications: CONNECTIONS Line In: POTS Out: DSLAM Connection: 1.72" (44 mm) 17.2" (437 mm) 11.7" (297 mm) 9.5 lbs. (4.3 kg) 12.0 lbs. (5.4 kg) 19" or 23" EIA/WECO rack or wall mountable All front-access chassis 24 circuits per chassis One 24-port splitter card T1.413 NEBS 3, Type 1; UL1950

100571

10/03

Lifeline POTS: ENVIRONMENTAL Operating: Non-Operating: Power:

50-pin (25 pair) RJ21 receptacle input from MDF 50-pin (25 pair) RJ21 receptacle back to MDF Make-before-break connectors used for voice signal 50-pin (25 pair) RJ21 Loop connectors are arranged so that removing line cards does not disturb or require the removal of loop cables. Connectors are secured to prevent unintentional disconnection under strain, chafing, or accidents. The chassis can be pre-wired for later use providing lifeline POTS service via make-before-break connectors incorporated in the chassis design. -40C to +70C 5-90% relative humidity -40C to +70C 5-95% relative humidity None

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

157

BroadWire 24
Specifications T1.413 Compliant ADSL/POTS Splitter Card
For All BroadWire 24 Chassis
ELECTRICAL Impedance: Insertion Loss: 900 Ohms, 5% (ZTc) < 1.00 dB, Short Loop, 1.004 KHz, ZTc = 900, ZTr = 600 < 0.75 dB, Long Loop, 1.004 KHz, ZTc = 900, ZTr = 600 > 65 dB at 30 KHz (typical, 600 Ohms term.) > 55 dB at > 300 KHz (maximum, 600 Ohms term.) < 0.10 dB 8 KHz (typical) 70 Sec maximum (0.3 3900 Hz) None 12.5 Ohms maximum per path > 8 dB ERL, > 5 dB SRL-L, >5 dB SRL-H, short and long loops > 2 dB SRL-H, short and long loop, single frequency DC to 1.104 MHz 100 mA DC > 58 dB, 200 1 KHz, straight line level decreasing to 53 dB at 3 KHz, 25 mA DC bias current 0 105 V 40 150 Vrms (at any frequency from 15 25 Hz) Fail-safe per UL1950 5C to +50C 5-90% relative humidity -40C to +70C 5-95% relative humidity

600 mm Products
100571

POTS Passband Ripple: POTS 3 dB Corner Frequency: Envelope Delay Distortion: Power Requirements: POTS Path Resistance: Voiceband Return Loss: Operating Bandwidth: POTS Loop Current: Longitudinal Balance: POTS Tip to Ring DC Voltage: POTS Ringing Signal: Power Cross: ENVIRONMENTAL Operating: Non-Operating:

4B3T ADSL/ISDN Splitter Card


For BroadWire 24 ETSI Chassis
ELECTRICAL Impedance: Insertion Loss: 150 Ohms 5% (typical), differential 1.2 dB at f < 60 KHz 2.0 dB at f < 80 KHz 65.0 dB at 138 < f < 1104 KHz < 0.1 dB 95 KHz (typical) 20 Sec maximum (0.3 - 95,000 Hz) None 12.5 Ohms maximum per path > 16 dB at f < 60 KHz > 14 dB at f < 80 KHz DC to 1.104 MHz 100 mA >55 dB Fail-safe per UL1950 -40C to +70C 5-90% relative humidity -40C to +70C 5-95% relative humidity

ISDN Passband Ripple: ISDN -3 dB Corner Frequency: Envelope Delay Distortion: Power Requirements: POTS Path Resistance: Passband Return Loss: Operating Bandwidth: POTS Loop Current: Longitudinal Balance: Power Cross: ENVIRONMENTAL Operating: Non-Operating:

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

158

BroadWire 24
Specifications 2B1Q ADSL/ISDN Splitter Card
For BroadWire 24 ETSI Chassis
ELECTRICAL Impedance: Insertion Loss: 135 Ohms 5% (typical), differential 0.8 dB at f 40 KHz 2.0 dB at f 80 KHz 65.0 dB at f 150 KHz < 0.1 dB 95 KHz (typical) 20 Sec maximum (0.3 - 95,000 Hz) None 12.5 Ohms maximum per path > 16 dB at f 40 KHz > 14 dB at f 80 KHz DC to 1.104 MHz 100 mA > 55 dB Fail-safe per UL1950 -40C to +70C 5-90% relative humidity -40C to +70C 5-95% relative humidity

600 mm Products
100571

ISDN Passband Ripple: ISDN -3 dB Corner Frequency: Envelope Delay Distortion: Power Requirements: POTS Path Resistance: Passband Return Loss: Operating Bandwidth: POTS Loop Current: Longitudinal Balance: Power Cross: ENVIRONMENTAL Operating: Non-Operating:

Complex Impedance ADSL/POTS Splitter Card


With 12 KHz and 16 KHz Billing Tone Support For BroadWire 24 ETSI Chassis
ELECTRICAL Impedance: Insertion Loss: Billing Tone Insertion Loss: POTS Passband Ripple: POTS -3 dB Corner Frequency: Envelope Delay Distortion: Power Requirements: POTS Path Resistance: Passband Return Loss: Operating Bandwidth: POTS Loop Current: Longitudinal Balance: POTS Tip to Ring DC Voltage: POTS Ringing Signal: Power Cross: ENVIRONMENTAL Operating: Non-Operating:

Complex, 270 Ohms + (750 Ohms || 150 nF) 1.0 dB at f 4 KHz > 55 dB at 30 KHz (typical, complex term.) < 3.0 dB at 12 KHz (maximum, 200 Ohms term.) < 3.0 dB at 16 KHz (maximum, 200 Ohms term.) < 0.10 dB 9 KHz (typical) 70 Sec maximum (0.3 - 3900 Hz) None 12.5 Ohms maximum per path Per ITU Q.552 DC to 1.104 MHz 100 mA DC > 58 dB (minimum) 0 - 105 V 40 - 150 Vrms (at any frequency from 15 - 25 Hz) Fail-safe per UL1950 -40C to +70C 5-90% relative humidity -40C to +70C 5-95% relative humidity

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

159

BroadWire 24
Ordering Information
Description BroadWire 24 ETSI platform For international deployment ETSI chassis T1.413 splitter card, 24 ports 2B1Q splitter card, 24 ports 4B3T splitter card, 24 ports Complex impedance splitter card, 24 ports Catalog Number

IPC-CMXXXXX-0012 IPC-RMT14DM-V242 IPC-RM2B1DX-V242 IPC-RM4B3DX-V242 IPC-RMFINDX-A242

600 mm Products

BroadWire 24 rear access platform For North American deployment Rear access chassis T1.413 splitter card, 24 ports BroadWire 24 front access platform For North American deployment Front access chassis and one pre-installed T1.413 splitter card Front access chassis T1.413 splitter card, 24 ports

IPC-CMXXXXX-0011 IPC-RMT14DM-V241

IPC-PMT14DM-A013 IPC-CMXXXXX-0013 IPC-RMT14DM-V243

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

160

Ethernet/Data Connectivity
Glide Cable Manager
Features
Integrated front, rear, horizontal, and vertical cable management Patented rib cage design eliminates horizontal support trays and bars Supports up to 912 ports on a single rack Built-in bend radius protection ensures network integrity Designed for quick and easy moves, adds, and changes Optional slack managers available for 8-, 10-, and 12-inch widths Fits standard EIA rack with three-inch channel Used for single rack or as inter-rack unit Optional crossover troughs and horizontal cable managers available Optional EIA-standard horizontal support bars available

600 mm Products

Ordering Information
Description Glide cable manager, vertical mount to equip both sides of a 7-foot rack, order two Glide Cable Manager units 6", front only, without slack manager 6", front only, with slack manager 6", without slack manager 8", without slack manager 10", without slack manager 12", without slack manager 8", with slack manager 10", with slack manager 12", with slack manager Top trough, 2 RU Crossover trough, 4 RU Black metal covers 41" 41" 41" 41" x x x x 6", four per pack 8", four per pack 10", four per pack 12", four per pack ADCCMVIBC06B4 ADCCMVIBC08B4 ADCCMVIBC10B4 ADCCMVIBC12B4 ADCCMVIB06F-2 ADCCMVIBS06F-2 ADCCM-06 ADCCM-08 ADCCM-10 ADCCM-12 ADCCMS-08 ADCCMS-10 ADCCMS-12 ADCCMTG02 ADCCMTG04 Catalog Number

Glide Cable Manager with Slack Managers

100571

Glide Cable Manager Shown in Cabinet

10/03

Cover in Black Metal

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

161

Ethernet/Data Connectivity
Glide Cable Manager
Ordering Information
Description Glide cable manager, cabinet mount ships 4 per pack 6" x 10 RU 6" x 20 RU Glide cable manager, cabinet mount, with cable retention ships 4 per pack ADCCMVIB-CB10-4 ADCCMVIB-CB-4 Catalog Number

600 mm Products

3" x 20 RU 6" x 20 RU

ADCCMVIB-3CB20-4 ADCCMVIB-6CB20-4 Installation Drawing for Glide Cable Manager, Cabinet Mount

Notes: Equips standard 7' cabinet with front or rear cable management. Order two 4-packs to equip front and rear of cabinet.

Ordering Information
Description Crossover troughs 2 RU, black 4 RU, black, 23" rack 4 RU, black Horizontal cable managers 2 RU 3 RU 4 RU With slack managers, 3 RU With slack managers, 4 RU Rear cable management bar, 19" 1" extension Rear cable management bar, 19" 4" extension ADCCMHIB-2U ADCCMHIB-3U ADCCMHIB-4U ADCCMHIBS-3U ADCCMHIBS-4U ADCCMRSB ADCCMRSB-4 2 RU Crossover Trough ADCCMTG02 ADCCMTG04-23 ADCCMTG04 Catalog Number

100571

Glide Cable Manager, Cabinet Mount

Ordering Information
Description Equipment racks 7' with 3" channel, black 7' with 3" channel, mill finish 7' UEF, black* Glide UEF adapter *Requires Glide UEF adapter Horizontal Cable Manager ADCRACKBLK73 ADCRACKMF73 ADCRACKBLK73UE ADCCMVIBUFAS 4 RU Crossover Trough Catalog Number

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

162

Ethernet/Data Connectivity

T1/E1 Demarcation Modular Patch Panels


ADC modular T1/E1 demarcation patch panels feature RJ48X or RJ48C wiring with a variety of rear termination options. The T1/E1 demarcation patch panels offer the end users a familiar RJ interface by which the T1/E1 signal can be accessed via industry standard RJ45 patch cables.

Features
Bantam nonintrusive T1/E1 signal monitoring (MPP-N28BA1 only) RJ48X (T1/E1 loopback) or RJ45C (no loopback) wiring Variety of rear termination options (wire-wrap, 64-pin, 50-pin) Category 3 performance Variety of mounting options (19- or 23-inch rack mounting, wall mounting) Compatible with industry standard RJ45 patch cords

600 mm Products

MPP-N28BA1 (front)

MPP-N28BA1 (rear)

Shorting Bar

Pair 1

Pair2

Pair 1

Pair2

MPP-CXFBA1 (front)

12 34 5 6 78

12 34 5 6 78

RJ48x

RJ48C

100571

RJ48X has a shorting bar between transmit and receive pins 1, 2 and 4, 5 to allow for T1/E1 signal loopback when no patch cord is present. The RJ48C has no shorting bar.

Ordering Information
Port Count 28 (with bantam monitoring ports) 28 28 14 8 5 28 24 24 32 Wiring RJ48X RJ48X RJ48X RJ48X RJ48X RJ48X RJ48C RJ48C shielded RJ48C RJ48C Rear Termination 64-pin or wire-wrap Wire-wrap 64-pin Wire-wrap, front access Wire-wrap, front access Wire-wrap, front access Wire-wrap 50-pin shielded 50-pin 50-pin EIA Mounting 2 RU x 19" or 23" 1 RU x 19" or 23" 1 RU x 19" Wall mount, 3.5" x 19" Wall mount, 3.5" x 14" Wall mount, 3.5" x 9.9" 1 RU x 19" or 23" 1 RU x 19" 1 RU x 19" 1 RU x 19" Catalog Number MPP-N28BA1 MPP-GDXBA1 MPP-DXZBA0 MPP-CXZXF4 MPP-CXZXF3 MPP-CXZXF2 MPP-GDXBA2 MPP-CXFBA1-S MPP-CXFBA1 MPP-CXZXBT2A

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

163

Ethernet/Data Connectivity
6000CHC Patch PanelsCategory 6
Features
Category 6 performance Backward compatible in component, link, and channel Patent-pending angle-right/angle-left port rotation feature reduces cable strain, reduces cable congestion, and enforces improved cable management with orderly flow of patch cords Color-coded, gas-tight 110 IDC provides sound connections for terminating stations, equipment, or tie cables Supports 10Base-T and 100Base-T Ethernet, 1000Base-T Ethernet, token ring, up to 155 Mbps ATM, and proposed 1000Base-TX Supports any next generation applications designed for TIA/EIA Category 6 transmission requirements 24-Port Patch Panel

48-Port Patch Panel

600 mm Products

96-Port Patch Panel

Ordering Information
Description 6000CHC patch panels Port Count 24 24 48 48 96 96 Wiring Configuration T568B T568A T568B T568A T568B T568A Rack Units 1 1 2 2 4 4 Catalog Number ADCPP24CH6B110 ADCPP24CH6A110 ADCPP48CH6B110 ADCPP48CH6A110 ADCPP96CH6B110 ADCPP96CH6A110

100571

Dimensions (W x H) 1 RU 19.0" x 1.75" (48.26 x 4.45 cm) 2 RU 19.0" x 3.50" (48.26 x 8.89 cm) 4 RU 19.0" x 7.0" (48.26 x 17.78 cm)

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

164

Ethernet/Data Connectivity
5000E Patch PanelsCategory 5e
Features
Exceeds Category 5e requirements Durable construction for maximum performance - Steel frame with black corrosion-resistant finish - High-impact UL 94 V-O polycarbonate used for all plastic parts - Modular 8-pin, 4-pair jacks Advanced features of 5000E include: - Patent-pending angle-right/angle-left ports - Color-coded icons for quick port identification Includes labeling for front and rear Supports 10Base-T, 100Base-T, and 1000Base-T Ethernet, token ring, 155 Mbps ATM Supports network speeds up to 1000 Mbps

48-Port

600 mm Products

24-Port 5000E Patch Panels

Ordering Information
Description 5000E patch panels Port Count 24 24 48 48 96 96 Wiring Configuration T568B T568A T568B T568A T568B T568A Rack Units 1 1 2 2 4 4 Catalog Number ADCPP245EB110 ADCPP245EA110 ADCPP485EB110 ADCPP485EA110 ADCPP965EB110 ADCPP965EA110

100571

Dimensions (W x H) 1 RU 19.0" x 1.75" (48.26 x 4.45 cm) 2 RU 19.0" x 3.50" (48.26 x 8.89 cm) 4 RU 19.0" x 7.0" (48.26 x 17.78 cm)

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

165

Ethernet/Data Connectivity
RJ45 Coupler PanelCategory 5
ADCs RJ45 coupler panel provides feed-through data and voice connectivity on the front and rear for Category 5 applications. Connectivity on the front of the panel accommodates standard RJ45 patch cords. Connectivity for hubs, routers and other active equipment on the back of the panel is also designed for RJ45 patch cords creating a convenient connection field for data applications. Includes port labeling for front and rear. Width is 48.26 cm (19-inch).

Ordering Information
Description Port Count 16 24 32 48 96 Rack Units 1 1 1 2 4 Catalog Number ADCPP16KSRJRJ ADCPP24505 ADCPP32KSRJRJ ADCPP48505 ADCPP96505

600 mm Products

RJ45 coupler panel, Category 5

RJ45 Coupler Panel Front View

100571

10/03

RJ45 Coupler Panel Rear View

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

166

Ethernet/Data Connectivity
Fast Ethernet Patch Panels
Features
Durable, quality construction for maximum performance Saves time in moves, adds, and changes Features secure and convenient 25-pair connections on the rear Modular 8-pin, 4-pair jacks on the front 5100 pin-out is 1,2-3,6 5800 has all pairs wired Includes write-on labels on front 5100 supports 10Base-T and 100Base-T Ethernet 5800 supports 10/100 and 1000Base-T Ethernet Optional icons speed circuit identification

5100 Patch Panel, 48-Port

600 mm Products

The first step to integrate Fast Ethernet traffic into a twisted pair network is to terminate both station-side and equipment-side connections on high performance ADC patch panels. For the Ethernet switching system, 5100 and 5800 patch panels provide convenient 25-pair (50-pin) female RJ21x connections on the rear, with rugged 8-pin modular jacks on the front. Port identification is accomplished with write-on port labels and optional icons.
Ordering Information
Description Pin-Out 1,2-3,6 1,2-3,6 1-8 1-8 Port Count 24 48 24 48 Rear Connector RJ21x RJ21x RJ21x RJ21x Rack Units 2 2 1 2 Catalog Number ADCPP245100TEL ADCPP485100TEL ADCPP245800BTEL ADCPP485800BTEL

100571

5100 5100 5800 5800

patch patch patch patch

panel panel panel, T568B panel, T568B

Dimensions (W x H) 1 RU 19.0" x 1.75" (48.26 x 4.45 cm) 2 RU 19.0" x 3.50" (48.26 x 8.89 cm)

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

167

Ethernet/Data Connectivity
6000 Multimedia Patch Panels

600 mm Products

6000 Multimedia Patch Panels Feature Single Circuit Access

Features
Category 6 performance Front or rear loading, single-circuit access saves time in moves, adds, and changes The highest density panel available Build each patch panel for twisted pair, fiber, and coax applications using any mix of 6000 modular jacks and 6000 media adapters - Jacks and media adapters installed and removed in single circuits - For Category 6 and Category 5e modular jack applications - Singlemode and multimode fiber applications using LX.5, SC, duplex SC, and ST media adapters - Handles applications for BNC, F-adapter, RCA-adapters, and S-Video adapters Creates angle-right/angle-left or conventional flat panel profile Simple installation and removal of individual jacks/adapters allows for rapid change-over and minimized downtime Supports 10Base-T, 100Base-T, and 1000Base-T Ethernet, token ring, up to 155 Mbps ATM, and proposed 1000Base-TX Includes port numbers or row identification and write-on panel labels Jacks and adapters install without panel faceplates or pairing of jacks/adapters Available in standard and high-density port sizes - Standard sizes 24-ports/1 RU, 48-ports/ 2 RU, 96-ports/4 RU - High-density sizes 32-ports/1 RU and 72-ports/2 RU

48-Port Panel with Angled 6000 Modular Jacks and Flat 6000 BNC Media Adapters

24-Port Panel with Flat 6000 Modular Jacks

Ordering Information
Description 6000 multimedia patch panel chassis Port Count 24 32 48 72 96 24 Rack Units 1 1 2 2 4 1 Catalog Number ADCPP246SUM ADCPP326SUM ADCPP486SUM ADCPP726SUM2U ADCPP966SUM ADCPP246SUMR3

100571

10/03

6000 multimedia 3" recessed patch panel chassis

Note: Order modular jacks and media adapters separately. Dimensions (W x H x d) 1 RU 19.0" x 1.75" x 0.50" (48.26 x 4.45 x 1.27 cm) 2 RU 19.0" x 3.47" x 0.50" (48.26 x 8.81 x 1.27 cm) 4 RU 19.0" x 6.97" x 0.50" (48.26 x 17.70 x 1.27 cm)

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

168

Ethernet/Data Connectivity
Features

6000 Multimedia Patch Panels6000 Modular Jacks and Icons

600 mm Products

Exceeds Category 5e and Category 6 component performance requirements Exceeds Category 5e and Category 6 link and channel requirements Backward compatible in component, link, and channel Supports 10Base-T and 100Base-T Ethernet, 1000Base-T Ethernet, token ring, up to 155 Mbps ATM, and proposed 1000Base-TX Supports any next generation applications designed for TIA/EIA Category 6 transmission requirements Available in flat profile or angled version for bend radius protection in T568A and T568B wiring schemes Includes one jack with color-coded 110 IDC connections and clear stuffer cap Universal T568A/B wiring

6000 Modular Jacks


Ordering Information
Description 6000 modular jacks Jack Type Angled Angled Flat Flat Wiring Configuration T568A/B T568A/B T568A/B T568A/B Category 6 5e 6 5e Catalog Number ADCJA6XX* ADCJA5XX* ADCJF6XX* ADCJF5XX* ADC6SADUMBKXX*

Blank inserts (Ships 10 per pack) *Replace the XX in the catalog number with choice of color, below.

100571

00 = Electrical Ivory 01 = Office White 02 = Black Angled

Icons
Ordering Information

Flat

Ordering Information
Description Icons for flat modular jacks and patch panels Catalog Number

10/03

Description Icons for angled modular jacks (Ships 25 per pack) Blank Data Voice

Catalog Number

ADC6SICNPXX* ADC6SICNDXX* ADC6SICNVXX*

Blank Data Voice

ADCICBXX* ADCICDXX* ADCICVXX*

*Replace the XX in the catalog number with choice of color, below. 03 = Red 04 = Green 05 = Blue 08 = Orange 09 = Yellow 10 = Purple 11 = Brown Icon

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

169

Ethernet/Data Connectivity
Features
Fully supports fiber, coax, RCA, and S-Video applications Available in angled or flat profiles Blank inserts available to fill unused ports on 6000 multimedia patch panels

6000 Multimedia Patch Panels6000 Media Adapters

600 mm Products

6000 Media Adapters

Ordering Information
Description Flat media adapters Singlemode LX.5 Multimode LX.5 Singlemode SC Singlemode duplex SC Multimode SC Multimode duplex SC Singlemode ST Multimode ST BNC F-adapter RCA-adapter S-Video Angled media adapters Singlemode LX.5 Multimode LX.5 Singlemode SC Singlemode duplex SC Multimode SC Multimode duplex SC Singlemode ST Multimode ST Blank inserts (Ships 10 per pack) ADC6SADANSMLX5XX* ADC6SADANMMLX5XX* ADC6SADANSMSCXX* ADC6SADANSMDSCXX* ADC6SADANMMSCXX* ADC6SADANMMDSCXX* ADC6SADANSMSTXX* ADC6SADANMMSTXX* ADC6SADUMBKXX* ADC6SADUMSMLX5XX* ADC6SADUMMMLX5XX* ADC6SADUMSMSCXX* ADC6SADUMSMDSCXX* ADC6SADUMMMSCXX* ADC6SADUMMMDSCXX* ADC6SADUMSMSTXX* ADC6SADUMMMSTXX* ADC6SADUMBNCXX* ADC6SADUMFCNXX* ADC6SADUMRCAFXX* ADC6SADUMSVHSFXX* Catalog Number

10/03

100571

*Replace the XX in the catalog number with choice of color, below. 00 = Electrical Ivory 01 = Office White 02 = Black

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

170

Ethernet/Data Connectivity
6000 High Performance Patch Cords
Features
Exceeds Category 5e requirements as well as ISO/IEC 11801 Telecommunications Standards Insert and remove patch cord without pulling back strain relief boot Every patch cord is tested to guarantee quality High-performance plugs preserve signal integrity and minimize crosstalk Fully supports data rates up to 1000 Mbps Wide variety of lengths and colors promotes simple, inexpensive installation and easy identification. Strain-relief boot limits bend radius and increases durability

600 mm Products

Fast Ethernet Hub

5100 Cable
25 26 27 28 29 30

37

38

39

40

41

42

Category

5100 Patch Panel

13

14

15

16

17

18

31
20 21 22 23 24

32

33

34

35

36

43

44

45

46

47

48

19 7 8 9 10 11 12

Horizontal Cable
13
7 1 2 3 4 5 6 8 9 10 11 12

6000 Patch Cord


14 15 16
17 18

19

20

21

22

23

24

5000E Patch Panel

100571

Work Station

Ordering Information
Description 6000 patch cord, with boots Category 6 6 6 5e 5e 5e Color White Gray Blue White Gray Blue Catalog Number ADCPC-66CHB-WTXX* ADCPC-66CHB-GYXX* ADCPC-66CHB-BLXX* ADCPC-RRC6B-WTXX* ADCPC-RRC6B-GYXX* ADCPC-RRC6B-BLXX*

10/03

6000 patch cord, with boots

*Replace the XX in the catalog number with desired length in feet: 03, 05, 07, 10, 15, 20, 25 or 50 feet. Custom colors and lengths available upon request.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

171

Ethernet/Data Connectivity
25-Pair Cable Assemblies
Features
Convenient 25-pair/50-pin RJ21x connections Connectors available in: - 180 exit angle - Hydra terminated with twelve numbered RJ45 plugs Exceeds Category 5 PowerSum requirements Supports 10Base-T and 100Base-T Ethernet

600 mm Products

The 25-pair cable assemblies are Category 5 PowerSum telco cables that provide precise connectivity between Fast Ethernet switches and 5100 or 5800 Patch Panels. With the convenience and precision of RJ21x connectors, 25-pair cable assemblies easily handle even high density Fast Ethernet switch configurations. In addition, the durable connectors feature a lock-down system that eliminates intermittency often associated with other telco cables.

RJ21x/RJ21x
Ordering Information
Description 25-pair cable assemblies Connector 1 Straight Exit 180 Connector 2 Straight Exit 180 Catalog Number ADCPC-T3T3-5100-XX*

*Replace the XX in the catalog number with desired length in feet: 05, 10, 15, 20, 25, 30, 35, 40, 45, or 50 feet.

RJ21x/Hydra
100571
Ordering Information
Description 25-pair cable assemblies Connector 1 Straight Exit 180 Straight Exit 180 Straight Exit 180 Connector 2 Hydra, longest to shortest plug: 1-12 Hydra, longest to shortest plug: 12-1 Hydra, plugs same length Catalog Number ADCPC-T3H1-5100-XX* ADCPC-T3H2-5100-XX* ADCPC-T3H3-5100-XX*

10/03

Note: Hydra connectors consist of 12 RJ45 plugs pinned 1,2-3,6. *Replace the XX in the catalog number with desired length in feet: 06, 10, or 15 feet.

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

172

Ethernet/Data Connectivity
6000 Faceplates
Features
Patent-pending design provides unique appearance for outlets Used for twisted pair, fiber, and coax applications Patent-pending fingertip access for easy removal and installation of designation windows Designed for use with 6000 modular jacks and 6000 media adapters For Category 6, and Category 5e modular jack applications For singlemode and multimode fiber applications using LX.5, SC, duplex SC, and ST media adapters Supports applications requiring BNC, F-adapters, RCA-adapters and S-Video adapters Accepts angled or flat jacks and media adapters Jacks and media adapters can be loaded from the front or the rear of the faceplate (front loading only on 1 to 3-port faceplate) All jacks and media adapters totally interchangeable on the faceplate Includes one faceplate, fingertip access designation windows, designation cards, and screws

600 mm Products

Ordering Information
Description 6000 faceplate Single gang Dimensions: 4.53" x 2.76" x 0.31" (11.51 x 7.01 x 0.79 cm) 6000 faceplate Single gang Dimensions: 4.53" x 2.76" x 0.31" (11.51 x 7.01 x 0.79 cm) 6000 faceplate Single gang Dimensions: 4.53" x 2.76" x 0.31" (11.51 x 7.01 x 0.79 cm) 6000 faceplate Double gang Dimensions: 4.53" x 4.60" x 0.31" (11.51 x 11.68 x 0.79 cm) 6000 faceplate Double gang Dimensions: 4.53" x 4.60" x 0.31" (11.51 x 11.68 x 0.79 cm) Jack/Adapter Type Flat Port Count 1 to 3 Catalog Number ADC6SFPUM031XX*

Angled or Flat

1 to 4

ADC6SFPUM041XX*

Flat

1 to 6

ADC6SFPUM061XX*

100571

Angled or Flat

1 to 8

ADC6SFPUM082XX*

Flat

1 to 12

ADC6SFPUM122XX*

*Replace the XX in the catalog number with choice of color, below. 00 = Electrical Ivory 01 = Office White 02 = Black

10/03

Ordering Information
Description 6000 designer faceplates includes screws. Accepts flat media adapters and modular jacks Single gang Double gang Insert ADC6SFPDC1XX ADC6SFPDC2XX ADC6SFPUM03DXX Catalog Number

Ordering Information
Description 6000 surface mount outlets Accepts flat media adapters and modular jacks. Includes fingertip designation windows, cards, and double-sided tape 2-ports 4-ports 6-ports 12-ports ADC6SSMUM02XX ADC6SSMUM04XX ADC6SSMUM062SAXX ADC6SSMUM12TRAXX Catalog Number

*Replace the XX in the catalog number with choice of color, below. 00 = Electrical Ivory 01 = Office White 02 = Black

*Replace the XX in the catalog number with choice of color, below. 01 = Office White 02 = Black

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

173

Ethernet/Data Connectivity
ADC IEEE 1394a FireWire Patch Panel
Features
IEEE 1394a compatible six-pin connectors 400Mb/s bandwidth High-density, 24 ports in one rack unit Plated panel housing to facilitate superior shielding and grounding Designation and port numbering

600 mm Products

ADC continues its leadership role in broadcast connectivity with the development of the new 1394a FireWire patch panel. The panel accommodates 24 ports in one rack unit and mounts in standard 19-inch racks. The panel offers customers a passive interconnection solution for their digital video editing needs. Industry-compatible six-pin IEEE 1394a connectors on both the front and rear of the panel allow customers to interconnect cameras, servers, workstations, and non-linear editing suites via FireWire at 400 Mbps bandwidth. The result is increased flexibility and productivity without sacrificing performance and reliability.

Ordering Information
Description One rack unit 24-port 1394a compatible FireWire patch panel Dimensions 1.75" x 19" x 2.25" (4.45 x 48.26 x 5.75 cm) Catalog Number VI-124-1394

Note: FireWire is a registered trademark of the 1394 Trade Association

10/03

100571

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

174

Media Converters

OptEnet Media Converter Platform

600 mm Products
10/03 100571

Features:
Modular design enables line card diversity within the same chassis Extend central office interconnect between network elements when distances are greater than 100 meters Ethernet delivery solution from central office to customer premises Reduce capital expenses associated with expensive optical line cards in network elements Auto-negotiation features eliminate the need for optical line card upgrade in network elements Redundant -48Vdc power supplies Supports SNMP and Telnet communication protocols Daisy-chain communication interfaces Supports 10Base-T, 100Base-TX and 1000Base-T UTP conversion to singlemode fiber Multimode fiber to singlemode fiber conversions Medium Dependent Interface Cross-over (MDI-X) eliminates network collisions NEBS Level 3, UL and FCC standards compliant

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

175

Media Converters
Common Equipment
OptEnet Modular Chassis

OptEnet Media Converter Platform

The OptEnet chassis is a modular chassis, which enables multiple types of line cards to be deployed simultaneously within the same chassis.

Features
Supports up to twelve OptEnet line cards All front access Accepts dual redundant power supplies 19 inches wide with 23-inch reverse mounting ears Two rack units high Optional SNMP and/or alarm functionality

600 mm Products

OptEnet 12 Slot Modular Chassis

Specifications
PHYSICAL Dimensions (HxWxD): Weight (empty): ENVIRONMENTAL Operating Conditions: Short Term Conditions: Storage Conditions: 3.5" x 17.5" x 5.75" (8.89 x 44.45 x 12.0 cm) 8.5 lbs (3.86 kg)

5C to 40C at 5% to 85% relative humidity -5C to 50C at 5% to 90% relative humidity -40C to 70C at 10% to 95% relative humidity (no condensation)

Ordering Information
Description Catalog Number ADCCE1100A

100571

OptEnet modular chassis: 12-port

Power Supply Modules


The OptEnet chassis accepts power from DC sources. Dual power supplies are deployed within the chassis to provide redundant power to all line cards along the back plane.

10/03

Features
-48Vdc (100 W) power supply +24Vdc (100 W) power supply Extended temperature versions available Power connection on the front panel Power and temperature status LEDs OptEnet DC Power Supply Module

Specifications
DC Input Voltage: -48Vdc, +24Vdc

Ordering Information
Description OptEnet +24Vdc power supply module OptEnet -48Vdc power supply module extended temp Catalog Number ADCCE2200A ADCCE2400A

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

176

Media Converters
Common Equipment
Communications Modules

OptEnet Media Converter Platform

If remote monitoring is required, a central processor unit (CPU) can be deployed within the OptEnet platform. An alarm card is available if only local alarm indications are required. The CPU and alarm card are optional. Only one of the two modules can be deployed in the chassis, so the network administrator must determine which alarm notification method is preferable.

600 mm Products

CPU Features:
Serial and Ethernet interface SNMP and Telnet communications protocols Compatible with all SNMP management platforms Daisy-chain up to four units, via one IP address Firmware upgrade via TFTP or serial Five simultaneous Telnet sessions

Alarm Card Features:


Normally open and normally closed alarm contacts OptEnet CPU OptEnet Alarm Module

Specifications
CPU Specifications Ethernet Interface: COM IN Interface: COM OUT Interface: Communications Protocol: Alarm Module Specifications Power ON Indicator: Alarm Indicator: Contact Closures: 10Base-T, RJ45 connector RS-232 DCE, RJ45 connector RS-232 DTE, RJ45 connector SNMP and ASCII Green Red Normally open and normally closed

100571

Ordering Information

Description

Catalog Number ADCCE3000A ADCCE3100A

10/03

OptEnet central processor unit OptEnet alarm module

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

177

Media Converters

OptEnet Media Converter Platform Media Conversion Line Cards


Singlemode to Multimode Optical Converter Line Card
The OptEnet singlemode to multimode media converter line card is one of a family of line cards that can be deployed in the OptEnet modular chassis. The card is designed to convert optical signals transported on a singlemode link to an optical signal that can be transported on a multimode link. The card supports any protocol and data rate between 10 Mbps to 622 Mbps (OC-12).

Supported Data Rates

600 mm Products

Signal Type/Protocol

Data Rate

Comments

Ethernet Fast Ethernet ATM/SONET/SDH

10 Mbps 100 Mbps 155 Mbps 622 Mbps

10BASE-FL 100BASE-FX OC-3 OC-12

Features
Single circuit line card Duplex transmission Link status and power LED indications Optical connections on front panel Protocol independent Supports data rates 10 Mbps up to OC-12

OptEnet Singlemode to Multimode Optical Converter Module

100571

Specifications
ELECTRICAL Input Power: MECHANICAL Chassis Compatibility: Fiber Optic Connectors: Dimensions (HxWxD): Weight: OPTICAL Singlemode Wavelength: Output Optical Power (XMT): Input Optical Power (RCV): Multimode Wavelength: Output Optical Power (XMT) 62.5/125m: 50/125m: Input Optical Power (RCV): 2.7 Watts maximum; normal operation

OptEnet modular chassis SC 1.14" x 8.07" x 7.4" (2.89 x 20.5 x 18.8 cm) 0.27 lbs (122 g)

10/03

1274 to 1356 nm range -15dBm minimum, -8dBm maximum -8dBm minimum, -32dBm maximum 1270 to 1380 nm range -20dBm minimum, -14dBm maximum -24dBm minimum, -14dBm maximum -26dBm minimum, -14 dBm maximum

Ordering Information
Description OptEnet singlemode to multimode, 10-622 Mb/s line card Catalog Number ADCPE6000A

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

178

Media Converters

OptEnet Media Converter Platform


OptEnet 10/100 Mbps Ethernet Line Card
The OptEnet 10/100 Mbps Ethernet media converter line card is designed to convert optical signals to electrical signals. The line card has an auto negotiation feature allowing it to detect and synchronize with either a 10Base-T or 100BASE-TX signal. The card supports 10BASE-T and 100BASE-T data rates over UTP and 1310 nm optics (singlemode fiber).

Supported Protocols
Application Data Rate 10 Mbps 100 Mbps 10/100 Mbps Media UTP Category 3, 4 or 5 (2-pair) UTP Category 5 (2-pair) 1300 singlemode fiber Distance 328 feet (100 m) 328 feet (100 m) 9.3 miles (15 km) (8/125m) Interface RJ45 RJ45 SC

600 mm Products

10Base-T 100Base-TX 100Base-LX

Features
Supports 10Base-T, and 100Base-T Full and half duplex transmission (transmit and receive) Ethernet and fiber optic link indicators Auto negotiation over fiber and copper (ANSI/TIA 785) MDI-X Auto-detects and corrects cross-over

OptEnet 100Base-LX Ethernet Line Card

100571

Specifications
ELECTRICAL Input Power: MECHANICAL Chassis Compatibility: Fiber Optic Connectors: Dimensions (HxWxD): Weight: Electrical Interface: Optical Interface: 1.75 Watts maximum; normal operation

10/03

OptEnet modular chassis SC 1.14" x 8.07" x 7.4" (2.89 x 20.5 x 18.8 cm) 0.27 lbs (122 g) RJ45 SC

OPTICAL Singlemode Wavelength: 1270 to 1380 nm range Output Optical Power (XMT) 8/125m: -15dBm minimum, -8dBm maximum Input Optical Power (RCV): -31dBm minimum, -7dBm maximum

Ordering Information
Description OptEnet 100BASE-LX (SC) line card Catalog Number ADCPE4200A

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

179

Media Converters

OptEnet Media Converter Platform Media Conversion Line Cards


OptEnet Gigabit Ethernet Line Card
The OptEnet 1000 Mbps media converter line card is designed to convert optical signals to electrical signals. The card supports 1000BASE-T data rates over UTP and 1310 nm optics (singlemode fiber).

Supported Protocols
Application Data Rate 1000 Mbps 1000 Mbps Media UTP Category 5e (4-pair) 1300 singlemode fiber Distance 328 feet (100 m) 6.2 miles (10 km) (8/125m) Interface RJ45 SC

600 mm Products

1000Base-TX 1000Base-LX

Features
Supports Gigabit Ethernet Duplex transmission (transmit and receive) Ethernet and fiber optic link indicators MDI-X Auto-detects and corrects cross-over OptEnet 1000Base-LX Line Card

Specifications
ELECTRICAL Input Power: MECHANICAL Chassis Compatibility: Fiber Optic Connectors: Dimensions (HxWxD): Weight: Electrical Interface: Optical Interface: OPTICAL Singlemode Wavelength: Output Optical Power (XMT) 8/125m: Input Optical Power (RCV):

2.2 Watts maximum; normal operation

100571

OptEnet modular chassis SC 1.14" x 8.07" x 7.4" (2.89 x 20.5 x 18.8 cm) 0.27 lbs (122 g) RJ45 SC

10/03

1270 to 1355 nm range -11dBm minimum, -3dBm maximum -22dBm minimum, -20dBm maximum

Ordering Information
Description OptEnet 1000BASE-LX (SC) line card Catalog Number ADCPE5100A

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

180

Media Converters

Work Area Media Converter

600 mm Products

Work Area Media Converter

Media Converter shown with 6000 Modular Jacks in 6000 Faceplate.

Features
Reduces work area clutter by placing media conversion circuitry behind the faceplate. Eliminates external power adapter and fiber jumper in workstation applications. Improves protection of circuits by securing circuitry behind the faceplate. Streamlines installation and troubleshooting with built-in intelligence for optical link integrity and UTP link integrity indicators at work area. Supports 10Base-T and 100Base-TX UTP and 10Base-FL, 100Base-SX, and 100Base-FX multimode fiber with auto negotiation.

Ordering Information
Description Ordering Number

100571

Work Area Media Converter Kits Mouse port power option 850 nm 1300 nm Kit includes media converter, power adapter, 3' PS/2 jumper, and 3' blue RJ45 patch cord Wall outlet power option 850 nm 1300 nm Kit includes media converter, power adapter, AC/DC wall outlet power adapter, and 3' blue RJ45 patch cord USB port power option 850 nm 1300 nm Kit includes media converter and USB patch cord Ordering notes: *Replace XX in ordering number with choice of color for media converter below 00 = Electrical Ivory 02 = Black 01 = Office White

ADC6S1SXSTMM1XX* ADC6S1FXSTMM1XX*

ADC6S1SXSTMM2XX* ADC6S1FXSTMM2XX*

10/03

ADC6S1SXSTMM3XXYY** ADC6S1FXSTMM3XXYY**

**To order USB port power cable, replace YY in ordering number with desired length in meters: 02, 05, 07, or 10. Replace XX in ordering number with choice of color for media converter

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

181

Customer Information and Assistance


Write:
ADC TELECOMMUNICATIONS, INC PO BOX 1101, MINNEAPOLIS, MN 55440-1101, USA ADC TELECOMMUNICATIONS (SPORE) PTE. LTD. 100 BEACH ROAD, #18-01, SHAW TOWERS. SINGAPORE 189702.

600 mm Products
100571 10/03

ADC EUROPEAN CUSTOMER SERVICE, INC BELGICASTRAAT 2, 1930 ZAVENTEM, BELGIUM

Phone:
Europe Sales Administration: +32-2-712-65 00 Technical Assistance: +32-2-712-65 42 European Toll Free Numbers UK: 0800 960236 Spain: 900 983291 France: 0800 914032 Germany: 0180 2232923 U.S.A. OR Canada Sales: 1-800-366-3891 Extension 73000 Technical Assistance: 1-800-366-3891 Extension 73475 Asia/Pacific Sales Administration: +65-6294-9948 Technical Assistance: +65-6393-0739 Elsewhere Sales Administration: +1-952-938-8080 Technical Assistance: +1-952-917-3475

Product Information and Technical Assistance:


euro_tac@adc.com asiapacific_tac@adc.com connectivity_tac@adc.com

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

182

Index
A
ACE/AGX-KEY . . . . . . . . . . .33 ACK-INTL . . . . . . . . . . . . . .141 ACK-INTL-N . . . . . . . . . . . .141 ACOK-PWNB . . . . . . . . . . .140 ADC6S1FXSTMM1XX . . . .181 ADC6S1FXSTMM2XX . . . .181 ADC6S1FXSTMM3XXYY . .181 ADC6S1SXSTMM1XX . . . .181 ADC6S1SXSTMM2XX . . . .181 ADC6S1SXSTMM3XXYY . .181 ADC6SADANMMDSCXX . .170 ADC6SADANMMLX5XX . .170 ADC6SADANMMSCXX . . .170 ADC6SADANMMSTXX . . .170 ADC6SADANSMDSCXX . . .170 ADC6SADANSMLX5XX . . .170 ADC6SADANSMSCXX . . . .170 ADC6SADANSMSTXX . . . .170 ADC6SADUMBKXX . .169,170 ADC6SADUMBNCXX . . . . .170 ADC6SADUMFCNXX . . . . .170 ADC6SADUMMMDSCXX .170 ADC6SADUMMMLX5XX . .170 ADC6SADUMMMSCXX . . .170 ADC6SADUMMMSTXX . . .170 ADC6SADUMRCAFXX . . . .170 ADC6SADUMSMDSCXX . .170 ADC6SADUMSMLX5XX . . .170 ADC6SADUMSMSCXX . . .170 ADC6SADUMSMSTXX . . . .170 ADC6SADUMSVHSFXX . . .170 ADC6SFPDC1XX . . . . . . . .173 ADC6SFPDC2XX . . . . . . . .173 ADC6SFPUM031XX . . . . . .173 ADC6SFPUM03DXX . . . . . .173 ADC6SFPUM041XX . . . . . .173 ADC6SFPUM061XX . . . . . .173 ADC6SFPUM082XX . . . . . .173 ADC6SFPUM122XX . . . . . .173 ADC6SICNDXX . . . . . . . . .169 ADC6SICNPXX . . . . . . . . . .169 ADC6SICNVXX . . . . . . . . .169 ADC6SSMUM02XX . . . . . .173 ADC6SSMUM04XX . . . . . .173 ADC6SSMUM062SAXX . . .173 ADC6SSMUM12TRAXX . . .173 ADCCE1100A . . . . . . . . . .176 ADCCE2200A . . . . . . . . . .176 ADCCE2400A . . . . . . . . . .176 ADCCE3000A . . . . . . . . . .177 ADCCE3100A . . . . . . . . . .177 ADCCM-06 . . . . . . . . . . . .161 ADCCM-08 . . . . . . . . . . . .161 ADCCM-10 . . . . . . . . . . . .161 ADCCM-12 . . . . . . . . . . . .161 ADCCMHIB-2U . . . . . . . . .162 ADCCMHIB-3U . . . . . . . . .162 ADCCMHIB-4U . . . . . . . . .162 ADCCMHIBS-3U . . . . . . . .162 ADCCMHIBS-4U . . . . . . . .162 ADCCMRSB . . . . . . . . . . . .162 ADCCMRSB-4 . . . . . . . . . .162 ADCCMS-08 . . . . . . . . . . .161 ADCCMS-10 . . . . . . . . . . .161 ADCCMS-12 . . . . . . . . . . .161 ADCCMTG02 . . . . . . .161,162 ADCCMTG04 . . . . . . .161,162 ADCCMTG04-23 . . . . . . . .162 ADCCMVIB-3CB20-4 . . . . .162 ADCCMVIB-6CB20-4 . . . . .162 ADCCMVIB-CB-4 . . . . . . . .162 ADCCMVIB-CB10-4 . . . . . .162 ADCCMVIB06F-2 . . . . . . . .161 ADCCMVIBC06B4 . . . . . . .161 ADCCMVIBC08B4 . . . . . . .161 ADCCMVIBC10B4 . . . . . . .161 ADCCMVIBC12B4 . . . . . . .161 ADCCMVIBS06F-2 . . . . . . .161 ADCCMVIBUFAS . . . . . . . .162 ADCICBXX . . . . . . . . . . . . .169 ADCICDXX . . . . . . . . . . . .169 ADCICVXX . . . . . . . . . . . . .169 ADCJA5XX . . . . . . . . . . . .169 ADCJA6XX . . . . . . . . . . . .169 ADCJF5XX . . . . . . . . . . . . .169 ADCJF6XX . . . . . . . . . . . . .169 ADCPC-66CHB-BLXX . . . . .171 ADCPC-66CHB-GYXX . . . .171 ADCPC-66CHB-WTXX . . . .171 ADCPC-RRC6B-BLXX . . . . .171 ADCPC-RRC6B-GYXX . . . .171 ADCPC-RRC6B-WTXX . . . .171 ADCPC-T3H1-5100-XX . . .172 ADCPC-T3H2-5100-XX . . .172 ADCPC-T3H3-5100-XX . . .172 ADCPC-T3T3-5100-XX . . .172 ADCPE4200A . . . . . . . . . .179 ADCPE5100A . . . . . . . . . .180 ADCPE6000A . . . . . . . . . .178 ADCPP16KSRJRJ . . . . . . . .166 ADCPP24505 . . . . . . . . . . .166 ADCPP245100TEL . . . . . . .167 ADCPP245800BTEL . . . . . .167 ADCPP245EA110 . . . . . . .165 ADCPP245EB110 . . . . . . . .165 ADCPP246SUM . . . . . . . . .168 ADCPP246SUMR3 . . . . . . .168 ADCPP24CH6A110 . . . . . .164 ADCPP24CH6B110 . . . . . .164 ADCPP326SUM . . . . . . . . .168 ADCPP32KSRJRJ . . . . . . . .166 ADCPP48505 . . . . . . . . . . .166 ADCPP485100TEL . . . . . . .167 ADCPP485800BTEL . . . . . .167 ADCPP485EA110 . . . . . . .165 ADCPP485EB110 . . . . . . . .165 ADCPP486SUM . . . . . . . . .168 ADCPP48CH6A110 . . . . . .164 ADCPP48CH6B110 . . . . . .164 ADCPP726SUM2U . . . . . . .168 ADCPP96505 . . . . . . . . . . .166 ADCPP965EA110 . . . . . . .165 ADCPP965EB110 . . . . . . . .165 ADCPP966SUM . . . . . . . . .168 ADCPP96CH6A110 . . . . . .164 ADCPP96CH6B110 . . . . . .164 ADCRACKBLK73 . . . . . . . .162 ADCRACKBLK73UE . . . . . .162 ADCRACKMF73 . . . . . . . .162 AUX-000040 . . . . . . . . . . .133 AUX-0X0165 . . . . . . . . . . .142 AUX-0X0381 . . . . . . . . . . .142 AUX-0X0383 . . . . . . . . . . .142 AUX-0X0466 . . . . . . . . . . .142 AUX-0X0467 . . . . . . . . . . .142 AUX-0X0468 . . . . . . . . . . .142 AUX-0X0802 . . . . . . . . . . .142 AUX-0X0803 . . . . . . . . . . .142 AUX-0X0915 . . . . . . . . . . .145 AUX-0X0916 . . . . . . . . . . .145 AUX-0X0917 . . . . . . . . . . .145 AUX-0X0918 . . . . . . . . . . .145 AUX-0X0919 . . . . . . . . . . .145 AUX-0X0925 . . . . . . . . . . .145 AUX-0X0926 . . . . . . . . . . .145 AUX-0X0927 . . . . . . . . . . .145 AUX-0X0928 . . . . . . . . . . .145 AUX-0X0929 . . . . . . . . . . .145 AUX-0X0930 . . . . . . . . . . .145 AUX-0X0933 . . . . . . . . . . .145 AUX-0X0934 . . . . . . . . . . .145 AUX-0X0935 . . . . . . . . . . .145 AUX-200022 . . . . . . . . . . .133 AUX-200064 . . . . . . . . . . .133 AUX-AC0003 . . . . . . . . . . .133 AUX-AC0004 . . . . . . . . . . .133 AUX-AC0005 . . . . . . . . . . .133

10/03

100571

600 mm Products

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

183

Index
B
BNC-1 . . . . . . . . . . . . . . . .120 BNC-2 . . . . . . . . . . . . . . . .120 BNC-3 . . . . . . . . . . . . . . . .120 BNC-4 . . . . . . . . . . . . . . . .120 BNC-7 . . . . . . . . . . . . . . . .120 BNC-RA-1 . . . . . . . . . . . . .120 BNC-RA-2 . . . . . . . . . . . . .120 BNC-RA-3 . . . . . . . . . . . . .120 BNC-RA-4 . . . . . . . . . . . . .120 BNC-RA-7 . . . . . . . . . . . . .120 BNC-TOOL-1 . . . . . . . . . . .121 BT2000 . . . . . . . . . . . . . . .121 DFX-1F0001 . . . . . . . . . . . .129 DFX-1F0001-DPM . . . . . . .129 DFX-2 . . . . . . . . . . . . . . . .128 DFX-210001 . . . . . . . . . . .128 DFX-210001-DPM . . . . . . .128 DFX-220001 . . . . . . . . . . .128 DFX-220001-DPM . . . . . . .128 DFX-230001 . . . . . . . . . . .128 DFX-400001 . . . . . . . . . . .128 DFX-500001 . . . . . . . . . . .128 DFX-9E0002 . . . . . . . . . . .128 DFX-9E0003 . . . . . . . . . . .129 DFX-9E0003-DPM . . . . . . .129 DFX-9E1000 . . . . . . . . . . .128 DFX-9E2000 . . . . . . . . . . .128 DFX-9E3000 . . . . . . . . . . .128 DFX-9E4000 . . . . . . . . . . .128 DFX-9E4000-S . . . . . . . . . .128 DFX-9E5000 . . . . . . . . . . .128 DFX-9F1000 . . . . . . . . . . . .129 DFX-9F1000-DPM . . . . . . .129 DFX-RSFA03 . . . . . . . . . . . .129 DFX-RSFA04 . . . . . . . . . . . .129 DFX-SHD001 . . . . . . . . . . .139 DFX-SHD002 . . . . . . . . . . .139 DFX-SHD003 . . . . . . . . . . .139 DFX-SHD004 . . . . . . . . . . .139 DFX-SHD005 . . . . . . . . . . .139 DFX-SHD006 . . . . . . . . . . .139 DMM-1656BLK . . . . . . . . .116 DMM-1656F . . . . . . . . . . .116 DMM-1656MF . . . . . . . . . .116 DMM-BBNCBLK . . . . . . . . .116 DMM-BBNCF . . . . . . . . . . .116 DMM-BBNCMF . . . . . . . . .116 DMM-BLANK . . . . . . . . . . .116 DPK-01 . . . . . . . . . . . . . . .108 DSX-3 CCUT . . . . . . . . . . .121 DSX-4R-MB160 . . . . . . . . .112 DSX-4R-MB260 . . . . . . . . .112 DSX-4R-MG130 . . . . . . . . .112 DSX-4R-MG140 . . . . . . . . .112 DSX-4R-MG160 . . . . . . . . .112 DSX-4R-MG230 . . . . . . . . .112 DSX-4R-MG240 . . . . . . . . .112 DSX-4R-MG260 . . . . . . . . .112 DSX-CCW/1000 . . . . . . . . .142 DSX-CCW/1500 . . . . . . . . .142 DSX-CCW/2000 . . . . . . . . .142 DSX-CCW/500 . . . . . . . . . .142 DSX4R-24B0-D24 . . . . . . .113 DSX4R-D24 . . . . . . . . . . . .113

E
E-501-L139 . . . . . . . . . . . . .48

F
F-1 . . . . . . . . . . . . . . . . . . .110 F-11/2 . . . . . . . . . . . . . . . .110 F-11/3 . . . . . . . . . . . . . . . .110 F-1/2 . . . . . . . . . . . . . . . . .110 F-1/4 . . . . . . . . . . . . . . . . .110 F-10 . . . . . . . . . . . . . . . . . .110 F-12 . . . . . . . . . . . . . . . . . .110 F-15 . . . . . . . . . . . . . . . . . .110 F-2 . . . . . . . . . . . . . . . . . . .110 F-2 1/2 . . . . . . . . . . . . . . . .110 F-2/10 . . . . . . . . . . . . . . . .110 F-3 . . . . . . . . . . . . . . . . . . .110 F-31/2 . . . . . . . . . . . . . . . .110 F-3/4 . . . . . . . . . . . . . . . . .110 F-3/8 . . . . . . . . . . . . . . . . .110 F-4 . . . . . . . . . . . . . . . . . . .110 F-5 . . . . . . . . . . . . . . . . . . .110 F-71/2 . . . . . . . . . . . . . . . .110 FEC-ACCCLMP01 . . . . . . . .27 FG-01A . . . . . . . . . . . . . . .107 FGS-ACC063 . . . . . . . . . . . .96 FGS-ASRI-10F . . . . . . . . . . . .93 FGS-ASRI-15F . . . . . . . . . . . .93 FGS-ASRI-5F . . . . . . . . . . . . .93 FGS-BTBL-C . . . . . . . . . . . . .91 FGS-BTBS-C . . . . . . . . . . . . .91 FGS-CD4E-A . . . . . . . . . . . .92 FGS-CD4E-B . . . . . . . . . . . . .94 FGS-CD9E-A . . . . . . . . . . . .92 FGS-CD9E-B . . . . . . . . . . . . .94 FGS-CDSA-AB . . . . . . . . . . .92 FGS-CH4E-A . . . . . . . . . . . .92 FGS-CH4E-B . . . . . . . . . . . . .94 FGS-CH9E-A . . . . . . . . . . . .92 FGS-CH9E-B . . . . . . . . . . . . .94 FGS-CHRT-A . . . . . . . . . . . . .92 FGS-CHRT-B . . . . . . . . . . . . .94 FGS-CHXP-A . . . . . . . . . . . .92 FGS-CHXP-B . . . . . . . . . . . . .94 FGS-HAEJ-C . . . . . . . . . . . . .91 FGS-HASB-1/2-36 . . . . . . . .93 FGS-HASB-1/2-48 . . . . . . . .93 FGS-HASB-5/8-36 . . . . . . . .93 FGS-HASB-5/8-48 . . . . . . . .93 FGS-HASK-C . . . . . . . . . . . .91 FGS-HCBL-12 . . . . . . . . . . . .93 FGS-HCBL-15 . . . . . . . . . . . .93 FGS-HDCB-C . . . . . . . . . . . .91

600 mm Products
10/03 100571

C
CA1-X0-09-571-A21-MG .107 CA1-X0-09-572-A21-MG .107 CA1-X0-09-573-A21-MG .107 CA1-X0-09-574-A21-MG .107 CA1-X0-09-575-A21-MG .107 CA1-X0-09-576-A21-MG .107 CA1-X0-09-577-A21-MG .107 CA1-X0-09-578-A21-MG .107 CA1-X0-09-634-A21-MG .107 CA1-X0-09-635-A21-MG .107 CCS-BLK . . . . . . . . . . . . . .121 CL-01M . . . . . . . . . . . . . . .107 CL-01M0 . . . . . . . . . . . . . .107 CL-02M . . . . . . . . . . .107,110 CL-02M0 . . . . . . . . . . . . . .107 CL-03M0 . . . . . . . . . . . . . .107 CL-04M . . . . . . . . . . . . . . .110 CL-04M0 . . . . . . . . . . . . . .107 CL-06M . . . . . . . . . . . . . . .110 CL-14M . . . . . . . . . . . . . . .110 CL-250M . . . . . . . . . . . . . .107 CL-300M . . . . . . . . . . . . . .107 CL-350M . . . . . . . . . . . . . .107 CMB-P-19 . . . . . . . . . . . . .110

D
D1M-1A2015 . . . . . . . . . .131 D1M-1A2016 . . . . . . . . . .131 D1M-1A2017 . . . . . . . . . .131 D3C-0024T . . . . . . . . . . . .117 D3C-WBOX06 . . . . . . . . . .118 DCK-01A . . . . . . . . . . . . . .107 DCK-02 . . . . . . . . . . . . . . .108 DFX-1 . . . . . . . . . . . . . . . .128 DFX-100001 . . . . . . . . . . .128 DFX-100001-DPM . . . . . . .128

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

184

Index
FGS-HDGR . . . . . . . . . . . . . .93 FGS-HDSI-AB . . . . . . . . . . . .93 FGS-HETR-1/2 . . . . . . . . . . .93 FGS-HETR-5/8 . . . . . . . . . . .93 FGS-HETR-5/8-A . . . . . . . . . .93 FGS-HETR-F-5/8 . . . . . . . . . .96 FGS-HFCK-1/2 . . . . . . . . . . .93 FGS-HFCK-5/8 . . . . . . . . . . .93 FGS-HFRR-10 . . . . . . . . . . . .96 FGS-HHEC-10 . . . . . . . . . . .96 FGS-HHGK . . . . . . . . . . . . . .96 FGS-HIFC-A . . . . . . . . . . . . .92 FGS-HIFC-B . . . . . . . . . . . . .94 FGS-HIFC-F . . . . . . . . . . . . . .95 FGS-HLBK . . . . . . . . . . . . . .93 FGS-HLDR-5/8 . . . . . . . . .91,93 FGS-HLR2-C . . . . . . . . . . . . .91 FGS-HMEC-A . . . . . . . . . . . .92 FGS-HMEC-B . . . . . . . . . . . .94 FGS-HMEC-C . . . . . . . . . . . .90 FGS-HMEC-F . . . . . . . . . . . .95 FGS-HMEC-G . . . . . . . . . . . .91 FGS-HNLR-AB . . . . . . . . . . .93 FGS-HNLR-F . . . . . . . . . . . . .96 FGS-HNTP-F-5/8 . . . . . . . . . .96 FGS-HNTR-1/2 . . . . . . . . . . .93 FGS-HNTR-5/8 . . . . . . . . . . .93 FGS-HNTR-5/8-A . . . . . . . . .93 FGS-HNTR-F-5/8 . . . . . . . . . .96 FGS-HNTS-5/8 . . . . . . . . . . .93 FGS-HNTS-5/8-LP . . . . . . . . .93 FGS-HNTS-F-5/8 . . . . . . . . . .96 FGS-HNTS-F-5/8-LP . . . . . . .96 FGS-HQKK . . . . . . . . . . . . . .96 FGS-HSHC-10 . . . . . . . . . . .90 FGS-HTHR-5/8-12 . . . . . .91,93 FGS-HTHR-5/8-30 . . . . . . . .93 FGS-HTHR-5/8-72 . . . . . . . .93 FGS-HTR2-1/2 . . . . . . . . . . .91 FGS-HTR2-5/8 . . . . . . . . . . .91 FGS-HTUB-1/2 . . . . . . . . . . .93 FGS-HTUB-2-AB . . . . . . . . . .91 FGS-HTUB-5/8 . . . . . . . . . . .93 FGS-HUFB-C . . . . . . . . . . . . .91 FGS-HVHG . . . . . . . . . . . . . .96 FGS-HWMB-C . . . . . . . . . . .96 FGS-HWMB-D . . . . . . . . . . .96 FGS-JUNC-G . . . . . . . . . . . .92 FGS-KDH2-C . . . . . . . . . . . .90 FGS-KQKB . . . . . . . . . . . . . .96 FGS-KT03-A . . . . . . . . . . . . .93 FGS-KT03-A1 . . . . . . . . . . . .93 FGS-KT03-C . . . . . . . . . . . . .90 FGS-KT09 . . . . . . . . . . . . . . .96 FGS-KTW1-C . . . . . . . . . . . .96 FGS-KTW1-CA . . . . . . . . . . .96 FGS-KTW1-E . . . . . . . . . . . .96 FGS-KTW2-D . . . . . . . . . . . .96 FGS-KTW4-C . . . . . . . . . . . .96 FGS-KTW4-E . . . . . . . . . . . .96 FGS-MCDS-AB . . . . . . . .92,94 FGS-MCDS-EX-AB . . . . . .92,94 FGS-MD4A-C . . . . . . . . . . . .90 FGS-MD4E-A . . . . . . . . . . . .92 FGS-MD4E-B . . . . . . . . . . . .94 FGS-MD4E-F . . . . . . . . . . . .95 FGS-MD4E-G . . . . . . . . . . . .91 FGS-MD9A-C . . . . . . . . . . . .90 FGS-MD9E-A . . . . . . . . . . . .92 FGS-MD9E-B . . . . . . . . . . . .94 FGS-MD9E-F . . . . . . . . . . . .95 FGS-MD9E-G . . . . . . . . . . . .91 FGS-MDRT-F . . . . . . . . . . . . .95 FGS-MDSA-AB . . . . . . . . . . .92 FGS-MDSA-AC . . . . . . . . . . .90 FGS-MDSA-F2B . . . . . . . . . .95 FGS-MDSA-FB . . . . . . . . . . .95 FGS-MDSA-GA . . . . . . . . . .91 FGS-MDSA-GB . . . . . . . . . . .91 FGS-MDSP-A . . . . . . . . . . . .92 FGS-MDSP-B . . . . . . . . . . . .94 FGS-MDSP-C . . . . . . . . . . . .90 FGS-MDSP-EX-A . . . . . . . . .92 FGS-MDSP-EX-B . . . . . . . . . .94 FGS-MDSP-F . . . . . . . . . . . . .95 FGS-MDSP-G . . . . . . . . . . . .91 FGS-MEX1-C-5F . . . . . . .90,93 FGS-MEXC-E-A . . . . . . . . . .90 FGS-MEXC-E-A/B/F . . . . . . . .90 FGS-MEXC-E-B . . . . . . . . . . .90 FGS-MEXC-E-F . . . . . . . . . . .90 FGS-MEXP-A/B/F . . . . . . . . .90 FGS-MEXP-E-A/B/F . . . . . . . .90 FGS-MEXP-LP-A/B/F . . . . . . .90 FGS-MEXP-LP-G . . . . . . . . . .91 FGS-MFAW-A . . . . . . . . . . . .92 FGS-MFAW-B . . . . . . . . . . . .94 FGS-MFAW-F . . . . . . . . . . . .95 FGS-MFTY-10F . . . . . . . . . . .96 FGS-MFTY-15F . . . . . . . . . . .96 FGS-MFTY-200F . . . . . . . . . .96 FGS-MFTY-5F . . . . . . . . . . . .96 FGS-MH4A-C . . . . . . . . . . . .90 FGS-MH4E-A . . . . . . . . . . . .92 FGS-MH4E-B . . . . . . . . . . . .94 FGS-MH4E-F . . . . . . . . . . . .95 FGS-MH4E-G . . . . . . . . . . . .91 FGS-MH9A-C . . . . . . . . . . . .90 FGS-MH9E-A . . . . . . . . . . . .92 FGS-MH9E-B . . . . . . . . . . . .94 FGS-MH9E-F . . . . . . . . . . . .95 FGS-MH9E-G . . . . . . . . . . . .91 FGS-MHIS-A . . . . . . . . . . . . .92 FGS-MHIS-B . . . . . . . . . . . . .94 FGS-MHIS-F . . . . . . . . . . . . .95 FGS-MHIS-JIG-A/B/F . .92,94,95 FGS-MHRT-A . . . . . . . . . . . .92 FGS-MHRT-B . . . . . . . . . . . .94 FGS-MHRT-F . . . . . . . . . . . . .95 FGS-MHRT-F/B . . . . . . . . . . .95 FGS-MHRT-G . . . . . . . . . . . .91 FGS-MHTA-C . . . . . . . . . . . .90 FGS-MHXP-A . . . . . . . . . . . .92 FGS-MHXP-B . . . . . . . . . . . .94 FGS-MHXP-B/F . . . . . . . . . . .95 FGS-MHXP-C . . . . . . . . . . . .90 FGS-MHXP-F . . . . . . . . . . . .95 FGS-MHXP-G . . . . . . . . . . . .91 FGS-MIDY-10F . . . . . . . . . . .96 FGS-MIDY-15F . . . . . . . . . . .96 FGS-MIDY-5F . . . . . . . . . . . .96 FGS-MJWR-A . . . . . . . . . . . .93 FGS-MJWR-C . . . . . . . . . . . .90 FGS-MJWR-D . . . . . . . . . . . .96 FGS-MKIT-ABF . . . . . . . . . . .96 FGS-MLDY-100F . . . . . . . . . .96 FGS-MLDY-150F . . . . . . . . . .96 FGS-MLDY-200F . . . . . . . . . .96 FGS-MLDY-250F . . . . . . . . . .96 FGS-MSDS-C . . . . . . . . . . . .90 FGS-MSHA-C . . . . . . . . . . . .90 FGS-MSHC-A . . . . . . . . . . . .92 FGS-MSHC-B . . . . . . . . . . . .94 FGS-MSHC-C . . . . . . . . . . . .96 FGS-MSHS-A . . . . . . . . . . . .92 FGS-MSHS-B . . . . . . . . . . . .94 FGS-MSHS-C . . . . . . . . . . . .96 FGS-MSHS-CA . . . . . . . . . . .96 FGS-MSHS-D . . . . . . . . . . . .96 FGS-MSHS-F . . . . . . . . . . . . .95 FGS-MSHS-G . . . . . . . . . . . .91 FGS-MSSC-A . . . . . . . . . . . .92 FGS-MSSC-B/G . . . . . . . .91,94 FGS-MSSC-F . . . . . . . . . . . . .95 FGS-MTRM-A . . . . . . . . . . . .93 FGS-MTRM-B . . . . . . . . . . . .94 FGS-MTRM-F . . . . . . . . . . . .95 FGS-MTRM-G . . . . . . . . . . .91 FGS-MU4A-C . . . . . . . . . . . .90

10/03

100571

600 mm Products

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

185

Index
FGS-MU4E-A . . . . . . . . . . . .92 FGS-MU4E-B . . . . . . . . . . . .94 FGS-MU4E-F . . . . . . . . . . . .95 FGS-MU4E-G . . . . . . . . . . . .91 FGS-MU9E-A . . . . . . . . . . . .92 FGS-MU9E-B . . . . . . . . . . . .94 FGS-MVAR-A . . . . . . . . . . . .92 FGS-MVAR-B . . . . . . . . . . . .94 FGS-MVAR-F . . . . . . . . . . . .95 FGS-SD4E-F . . . . . . . . . . . . .95 FGS-SD9E-F . . . . . . . . . . . . .95 FGS-SDSA-FB . . . . . . . . . . . .95 FGS-SH4E-F . . . . . . . . . . . . .95 FGS-SH9E-F . . . . . . . . . . . . .95 FGS-SHRT-F . . . . . . . . . . . . .95 FGS-SHRT-F/B . . . . . . . . . . . .95 FGS-SHXP-B/F . . . . . . . . . . . .95 FGS-SHXP-F . . . . . . . . . . . . .95 FGS-SU4E-F . . . . . . . . . . . . .95 FHA-01A . . . . . . . . . . . . . .107 FL1-6P2SC003 . . . . . . . . . . .33 FL1-6P4SC003 . . . . . . . . . . .33 FL1-6P5BC003 . . . . . . . . . . .33 FL1-6P6BC003 . . . . . . . . . . .33 FL1-6P7SC003 . . . . . . . . . . .33 FL1-6P8SC003 . . . . . . . . . . .33 FL1-6P9BC003 . . . . . . . . . . .33 FL1-6PABC003 . . . . . . . . . . .33 FL1-6PCSC003 . . . . . . . . . . .33 FL1-6PDBC003 . . . . . . . . . . .33 FL1-6PESC003 . . . . . . . . . . .33 FL1-6PFSC003 . . . . . . . . . . .33 FL1-6PJSC003 . . . . . . . . . . .33 FL1-6PKSC003 . . . . . . . . . . .33 FL1-6PLSC003 . . . . . . . . . . .33 FL1-6PPSC003 . . . . . . . . . . .33 FL1-6PRSC003 . . . . . . . . . . .33 FL1-6PXBC003 . . . . . . . . . . .33 FL1-6PYBC003 . . . . . . . . . . .33 FL1-ACC001 . . . . . . . . . . . .33 FL1-ACC002 . . . . . . . . . . . .33 FL1-ACC003 . . . . . . . . . . . .33 FL1-M-3M . . . . . . . . . . . . . .33 FL1-M-FT . . . . . . . . . . . . . . .33 FL1-M-HS . . . . . . . . . . . . . . .33 FL1-M-NT . . . . . . . . . . . . . . .33 FL1-M-RT . . . . . . . . . . . . . . .33 FL2-12RPNL . . . . . . . . . . . . .40 FL2-12TS350 . . . . . . . . . . . .42 FL2-144SPNL . . . . . . . . . . . .41 FL2-144SPNL2 . . . . . . . . . . .41 FL2-16FSD525 . . . . . . . . . . .43 FL2-19MAX0175 . . . . . . . . .50 FL2-19MAX0350 . . . . . . . . .50 FL2-19MAX0525 . . . . . . . . .50 FL2-19MAX0700 . . . . . . . . .50 FL2-19MAX0875 . . . . . . . . .50 FL2-19MAX1050 . . . . . . . . .50 FL2-19MAX1400 . . . . . . . . .50 FL2-19MAX1750 . . . . . . . . .50 FL2-24RPNL . . . . . . . . . . . . .40 FL2-24TS525 . . . . . . . . . . . .42 FL2-28FSD875 . . . . . . . . . . .43 FL2-2RSTORE . . . . . . . . . . . .44 FL2-36RPNL . . . . . . . . . . . . .40 FL2-48RPNL . . . . . . . . . . . . .40 FL2-48SPNL . . . . . . . . . . . . .41 FL2-48SPNL2 . . . . . . . . . . . .41 FL2-48TS875 . . . . . . . . . . . .42 FL2-4VAM525 . . . . . . . . . . .52 FL2-4WVAM3RU . . . . . . . . .52 FL2-4WVAM3RU-600 . . . . .52 FL2-600MM0175 . . . . . . . . .51 FL2-600MM0350 . . . . . . . . .51 FL2-600MM0525 . . . . . . . . .51 FL2-600MM0700 . . . . . . . . .51 FL2-600MM0875 . . . . . . . . .51 FL2-600MM1050 . . . . . . . . .51 FL2-600MM1400 . . . . . . . . .51 FL2-600MM1750 . . . . . . . . .51 FL2-6PBLNK . . . . . . . . . . . . .45 FL2-6PMMDSC . . . . . . .33, 45 FL2-6PMMFC . . . . . . . . .33, 45 FL2-6PMMFC-Z . . . . . . . . . .45 FL2-6PMMLC . . . . . . . . .33, 45 FL2-6PMMLX . . . . . . . . .33, 45 FL2-6PMMSC . . . . . . . . .33, 45 FL2-6PMMSC-Z . . . . . . . . . .45 FL2-6PMMST . . . . . . . . .33, 45 FL2-6PMMST-Z . . . . . . . . . . .45 FL2-6PSMAE2 . . . . . . . .33, 45 FL2-6PSMAFC . . . . . . . .33, 45 FL2-6PSMALX . . . . . . . .33, 45 FL2-6PSMASC . . . . . . . .33, 45 FL2-6PSMDSC . . . . . . . .33, 45 FL2-6PSMDSC-Z . . . . . . . . . .33 FL2-6PSMFC . . . . . . . . .33, 45 FL2-6PSMFC-Z . . . . . . . .33, 45 FL2-6PSMFC/SC . . . . . . . . . .45 FL2-6PSMLC . . . . . . . . .33, 45 FL2-6PSMSC . . . . . . . . .33, 45 FL2-6PSMSC-Z . . . . . . . .33, 45 FL2-6PSMST . . . . . . . . . .33, 45 FL2-6PSMST-Z . . . . . . . .33, 45 FL2-6PSMST/SC . . . . . . . . . .45 FL2-6RSTORE . . . . . . . . . . . .44 FL2-6VAM700 . . . . . . . . . . .52 FL2-72RPNL . . . . . . . . . . . . .40 FL2-72TS140 . . . . . . . . . . . .42 FL2-96RPNL . . . . . . . . . . . . .40 FL2-96SPNL . . . . . . . . . . . . .41 FL2-96SPNL2 . . . . . . . . . . . .41 FL2-96TS175 . . . . . . . . . . . .42 FL2-9VAM105 . . . . . . . . . . .52 FL2-ACC006 . . . . . . .33,40,47 FL2-ACC007 . . . . .33,40,41,47 FL2-ACC008 . . . . . . . . . . . .40 FL2-ACC011 . . . . . . . . . . . .47 FL2-ACC012 . . . . . . . . . . . .47 FL2-ACC021 . . . . . . .40,41,47 FL2-ACC033 . . . . . . . . . .40,47 FL2-ACC051 . . . . . . . . . . . .47 FL2-BLNKFULL0350 . . . . . . .47 FL2-BLNKFULL0525 . . . . . . .47 FL2-BLNKFULL0700 . . . . . . .47 FL2-BLNKFULL0875 . . . . . . .47 FL2-BLNKFULL1050 . . . . . . .47 FL2-BLNKVCG0350 . . . . . . .47 FL2-BLNKVCG0875 . . . . . . .47 FL2-BLNKVCG1050 . . . . . . .47 FL2-CST60525 . . . . . . . . . . .43 FL2-ETEB0175 . . . . . . . . . . .51 FL2-ETEB0350 . . . . . . . . . . .51 FL2-ETEB0525 . . . . . . . . . . .51 FL2-ETEB0700 . . . . . . . . . . .51 FL2-ETEB0875 . . . . . . . . . . .51 FL2-ETEB1050 . . . . . . . . . . .51 FL2-ETEB1400 . . . . . . . . . . .51 FL2-ETEB1700 . . . . . . . . . . .51 FL2-EUROIMP-26-600-A . . .48 FL2-EUROIMP-67 . . . . . . . . .48 FL2-EUROIMP-REAR . . . . . . .48 FL2-FLMT0175 . . . . . . . . . . .49 FL2-FLMT0350 . . . . . . . . . . .49 FL2-FLMT0525 . . . . . . . . . . .49 FL2-FLMT0700 . . . . . . . . . . .49 FL2-FLMT0875 . . . . . . . . . . .49 FL2-FLMT1050 . . . . . . . . . . .49 FL2-HZSTORE . . . . . . . . . . . .44 FL2-HZSTORE-600 . . . . . . . .44 FL2-HZSTORE-FLMT . . . . . . .44 FL2-HZSTORE-WMNT . . . . . .44 FL2-RSPLCE-FT . . . . . . . .41,42 FL2-RSPLCE-HS . . . . . . . .41,42 FL2-RSPLCE-MT . . . . . . . .41,42 FL2-RSPLCE-NT . . . . . . . .41,42 FL2-TR2000 . . . . . . . . . . . . .44 FMT-2SAP01 . . . . . . . . . . . .71 FMT-2SAP02 . . . . . . . . . . . .71

10/03

100571

600 mm Products

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

186

Index
FMT-2SAP03 . . . . . . . . . . . .71 FMT-2SAP04 . . . . . . . . . . . .71 FMT-2SAP05 . . . . . . . . . . . .71 FMT-2SAP07 . . . . . . . . . . . .71 FMT-2SAP09 . . . . . . . . . . . .71 FMT-2SAP0F . . . . . . . . . . . . .71 FMT-2SAP0J . . . . . . . . . . . . .71 FMT-2SAP0K . . . . . . . . . . . .71 FMT-2SAP0L . . . . . . . . . . . . .71 FMT-2SAP0N . . . . . . . . . . . .71 FMT-2SAP0P . . . . . . . . . . . . .71 FMT-6SAP02 . . . . . . . . . . . .76 FMT-6SAP06 . . . . . . . . . . . .76 FMT-6SAP07 . . . . . . . . . . . .76 FMT-6SAP08 . . . . . . . . . . . .76 FMT-6SAP09 . . . . . . . . . . . .76 FMT-6SAP0F . . . . . . . . . . . . .76 FMT-6SAP0J . . . . . . . . . . . . .76 FMT-6SAP0L . . . . . . . . . . . . .76 FMT-6SAP0N . . . . . . . . . . . .76 FMT-6SAP0X . . . . . . . . . . . .76 FMT-6SAP0Y . . . . . . . . . . . .76 FMT-ACC01B . . . . . . . . . . . .71 FMT-ACC01P . . . . . . . . . . . .71 FMT-ACC21B . . . . . . . . . . . .76 FMT-ACC21P . . . . . . . . . . . .76 FMT-ACCCLMP01 . . . . . .71,76 FMT-ACCCLMP02 . . . . . .71,76 FMT-ACCWLMT01 . . . . . . . .71 FMT-GVM00000-A72P . . . . .77 FOC-TERMFC-P . . . . . . . . . .59 FOC-TERMSC-P . . . . . . . . . .59 FOC-TERMST-P . . . . . . . . . . .59 FP-G . . . . . . . . . . . . . . . . . .108 FST-3M . . . . . . . . . . . . . . . . .33 FST-DRS12-HS . . . . . . . . .41,42 FST-DRS12-MT . . . . . . . .41,42 FST-DRS24-NT . . . . . . . . .41,42 FST-FT . . . . . . . . . . . . . . . . . .33 FST-HS . . . . . . . . . . . . . . . . .33 FST-MT . . . . . . . . . . . . . . . . .33 FST-NT . . . . . . . . . . . . . . . . .33 FST-RCM . . . . . . . . . . . . . . .33 FST-RT . . . . . . . . . . . . . . . . .33 FVM-19X175 . . . . . . . . . . . .53 FVM-19X350 . . . . . . . . . . . .53 FVM-23X400 . . . . . . . . . . . .53

I
IBF-1ENCDOR . . . . . . . . . .132 IBF-1ENCEG . . . . . . . . . . . .132 IBF-RSC021 . . . . . . . . . . . .125 IBR-D3C002 . . . . . . . . . . . .117 IBR-D3S002 . . . . . . . . . . . .114 IPA-K1 . . . . . . . . . . . . . . .33,47 IPA-K2 . . . . . . . . . . . . . . .33,47 IPC-CEXXXXX-0052 . . . . . .153 IPC-CEXXXXX-0101 . . . . . .153 IPC-CMXXXXX-0011 . . . . .160 IPC-CMXXXXX-0012 . . . . .160 IPC-CMXXXXX-0013 . . . . .160 IPC-PMT14DM-A013 . . . . .160 IPC-RM2B1DX-V242 . .153,160 IPC-RM4B3DX-V242 . .153,160 IPC-RMBYPXX-0242 . . . . .153 IPC-RMETSDE-V242 . . . . . .153 IPC-RMFINDX-A242 . . . . . .160 IPC-RMGERDX-V242 . . . . .153 IPC-RMT14DM-V241 . . . . .160 IPC-RMT14DM-V242 .153,160 IPC-RMT14DM-V243 . . . . .160

600 mm Products

MX6-ENDGRD . . . . . . . . . . .25 MX6-IMP150 . . . . . . . . . . . .25 MX6-IMP200 . . . . . . . . . . . .25 MX6-JSM00000 . . . . . . . . . .25 MX6-JSM80000 . . . . . . . . . .25 MX6-SPL6030-1440-D . . . . .27 MX6-SPL6030-1440-U . . . . .27 MX6-SPLIFCCLMP . . . . . . . .27 MX6-TSF6030 . . . . . . . . . . .19 MX6-TSF8030 . . . . . . . . . . .19 MX6-VAMCHAS-L . . . . . . . .23 MX6-VAMCHAS-R . . . . . . . .23

N
NGF-ACCCLMP04 . . . . . . . .16 NGF-ACCCLMP08 . . . . . . . .16 NGF-ACCFOTSB300 . . . . . . .14 NGF-ACCOSPKIT02 . . . . . . . .7 NGF-ACCRCMSLD . . . . . . . . .7 NGF-ACCRCMSLU . . . . . . . . .7 NGF-ACCRCMSRD . . . . . . . . .7 NGF-ACCRCMSRU . . . . . . . . .7 NGF-ETSIACCEG . . . . . . . . .16 NGF-ETSIEB6060-19 . . . . . . .15 NGF-ETSIF3ACCEG . . . . . . .16 NGF-ETSIF3EB6048-19 . . . . .15 NGF-ETSIF3MDF6048 . . . . . . .4 NGF-ETSIMDF6060 . . . . . . . .3 NGF-F3ACCFOTSB300 . . . . .14 NGF-SLM7A100 . . . . . . . . . . .5

K
KLM Dummy . . . . . . . . . . .109 KLM-05 . . . . . . . . . . . . . . .109 KLM-10 . . . . . . . . . . . . . . .109 KLM-15 . . . . . . . . . . . . . . .109 KLM-20 . . . . . . . . . . . . . . .109 KLM-25 . . . . . . . . . . . . . . .109 KLM-30 . . . . . . . . . . . . . . .109

100571

O
OSP-CLPFEC-LG . . . . . . . . . .26

L
LCA-000009 . . . . . . . . . . .121

10/03

P
P-1 . . . . . . . . . . . . . . . . . . .110 P-11/2 . . . . . . . . . . . . . . . .110 P-11/3 . . . . . . . . . . . . . . . .110 P-1/2 . . . . . . . . . . . . . . . . .110 P-1/4 . . . . . . . . . . . . . . . . .110 P-10 . . . . . . . . . . . . . . . . . .110 P-12 . . . . . . . . . . . . . . . . . .110 P-15 . . . . . . . . . . . . . . . . . .110 P-2 . . . . . . . . . . . . . . . . . . .110 P-21/2 . . . . . . . . . . . . . . . .110 P-2/10 . . . . . . . . . . . . . . . .110 P-3 . . . . . . . . . . . . . . . . . . .110 P-31/2 . . . . . . . . . . . . . . . .110 P-3/4 . . . . . . . . . . . . . . . . .110 P-3/8 . . . . . . . . . . . . . . . . .110

M
MPP-CXFBA1 . . . . . . . . . . .163 MPP-CXFBA1-S . . . . . . . . .163 MPP-CXZXBT2A . . . . . . . . .163 MPP-CXZXF2 . . . . . . . . . . .163 MPP-CXZXF3 . . . . . . . . . . .163 MPP-CXZXF4 . . . . . . . . . . .163 MPP-DXZBA0 . . . . . . . . . . .163 MPP-GDXBA1 . . . . . . . . . .163 MPP-GDXBA2 . . . . . . . . . .163 MPP-N28BA1 . . . . . . . . . . .163 MX6-24SPNL-L . . . . . . . . . . .24 MX6-24SPNL-R . . . . . . . . . .24 MX6-ACC001 . . . . . . . . . . .26

G
GMT Dummy . . . . . . . . . . .110

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

187

Index
P-4 . . . . . . . . . . . . . . . . . . .110 P-5 . . . . . . . . . . . . . . . . . . .110 P-7 1/2 . . . . . . . . . . . . . . . .110 PCH-MMXB-XXX . . . . . . . .119 PFGC-PD4E-B . . . . . . . . . . .101 PFGC-PD4E-C . . . . . . . . . .100 PFGC-PD4E-F . . . . . . . . . . .101 PFGC-PDNE-B . . . . . . . . . .101 PFGC-PDNE-C . . . . . . . . . .100 PFGC-PDNE-F . . . . . . . . . . .101 PFGC-PDSA-B/F . . . . . . . . .101 PFGC-PDSA-C/B . . . . . . . . .100 PFGC-PDSA-C/F . . . . . . . . .100 PFGC-PH4E-B . . . . . . . . . . .101 PFGC-PH4E-C . . . . . . . . . .100 PFGC-PH4E-F . . . . . . . . . . .101 PFGC-PH9E-B . . . . . . . . . . .101 PFGC-PH9E-C . . . . . . . . . .100 PFGC-PH9E-F . . . . . . . . . . .101 PFGC-PHRT-B . . . . . . . . . . .101 PFGC-PHRT-C . . . . . . . . . . .100 PFGC-PHRT-F . . . . . . . . . . .101 PFGC-PHRT-F/B . . . . . . . . . .101 PFGC-PHXP-B . . . . . . . . . . .101 PFGC-PHXP-C . . . . . . . . . .100 PFGC-PHXP-F . . . . . . . . . . .101 PFGC-PSHS-B . . . . . . . . . . .101 PFGC-PSHS-C . . . . . . . . . . .100 PFGC-PSHS-F . . . . . . . . . . .101 PFGC-PU4E-B . . . . . . . . . . .101 PFGC-PU4E-C . . . . . . . . . .100 PFGC-PU4E-F . . . . . . . . . . .101 PFGC-PUPE-B . . . . . . . . . . .101 PFGC-PUPE-C . . . . . . . . . . .100 PFGC-PUPE-F . . . . . . . . . . .101 PFGF-DSPT-C/B/F . . . . . . . .102 PFGF-EADSPT-C/B/F . . . . . .102 PFGF-EAESPT-C/B/F . . . . . . .102 PFGF-EALSPT-C/B/F . . . . . . .102 PFGF-EASSPT-C/B . . . . . . . .102 PFGF-ESPT-C/B/F . . . . . . . . .102 PFGF-HEXT . . . . . . . . . . . . .102 PFGF-HFIN . . . . . . . . . . . . .102 PFGF-HMST . . . . . . . . . . . .102 PFGF-HSPL . . . . . . . . . . . . .102 PFGF-KT03-B . . . . . . . . . . .102 PFGF-KT03-C . . . . . . . . . . .102 PFGF-LSPT-C/B/F . . . . . . . . .102 PFGF-MIDY-XFI . . . . . . . . . .102 PFGF-PD4E-B . . . . . . . . . . .101 PFGF-PD4E-C . . . . . . . . . . .100 PFGF-PD4E-F . . . . . . . . . . .101 PFGF-PDNE-B . . . . . . . . . . .101 PFGF-PDNE-C . . . . . . . . . . .100 PFGF-PDNE-F . . . . . . . . . . .101 PFGF-PDSA-B/F . . . . . . . . . .101 PFGF-PDSA-C/B . . . . . . . . .100 PFGF-PDSA-C/F . . . . . . . . .100 PFGF-PFPT-B . . . . . . . . . . . .101 PFGF-PFPT-C . . . . . . . . . . . .100 PFGF-PFPT-F . . . . . . . . . . . .101 PFGF-PH4E-B . . . . . . . . . . .101 PFGF-PH4E-C . . . . . . . . . . .100 PFGF-PH4E-F . . . . . . . . . . .101 PFGF-PH9E-B . . . . . . . . . . .101 PFGF-PH9E-C . . . . . . . . . . .100 PFGF-PH9E-F . . . . . . . . . . .101 PFGF-PHRT-B . . . . . . . . . . .101 PFGF-PHRT-C . . . . . . . . . . .100 PFGF-PHRT-F . . . . . . . . . . . .101 PFGF-PHRT-F/B . . . . . . . . . .101 PFGF-PHXP-B . . . . . . . . . . .101 PFGF-PHXP-C . . . . . . . . . . .100 PFGF-PHXP-F . . . . . . . . . . .101 PFGF-PIFC . . . . . . . . . . . . .102 PFGF-PJWR-B . . . . . . . . . . .101 PFGF-PJWR-C . . . . . . . . . . .100 PFGF-PJWR-F . . . . . . . . . . .101 PFGF-PMEC-B . . . . . . . . . .101 PFGF-PMEC-C . . . . . . . . . .100 PFGF-PMEC-F . . . . . . . . . . .101 PFGF-PPSC-B . . . . . . . . . . .101 PFGF-PSHS-B . . . . . . . . . . .101 PFGF-PSHS-C . . . . . . . . . . .100 PFGF-PSHS-F . . . . . . . . . . .101 PFGF-PTRM-B . . . . . . . . . . .101 PFGF-PTRM-C . . . . . . . . . .100 PFGF-PTRM-F . . . . . . . . . . .101 PFGF-PU4E-B . . . . . . . . . . .101 PFGF-PU4E-C . . . . . . . . . . .100 PFGF-PU4E-F . . . . . . . . . . .101 PFGF-PUPE-B . . . . . . . . . . .101 PFGF-PUPE-C . . . . . . . . . . .100 PFGF-PUPE-F . . . . . . . . . . .101 PFGF-SSPT-C/B . . . . . . . . . .102 PGS-110005 . . . . . . . . . . .120 PGS-110006 . . . . . . . . . . .120 PJ1208 . . . . . . . . . . . . . . . .141 PJ1210 . . . . . . . . . . . . . . . .141 PJ1212 . . . . . . . . . . . . . . . .141 PJ1308 . . . . . . . . . . . . . . . .141 PJ1310 . . . . . . . . . . . . . . . .141 PJ1312 . . . . . . . . . . . . . . . .141 PJ1415 . . . . . . . . . . . . . . . .141 PJ1420 . . . . . . . . . . . . . . . .141 PJ1425 . . . . . . . . . . . . . . . .141 PJ1430 . . . . . . . . . . . . . . . .141 PJ1450 . . . . . . . . . . . . . . . .141 PJ1514 . . . . . . . . . . . . . . . .141 PJ1520 . . . . . . . . . . . . . . . .141 PJ1525 . . . . . . . . . . . . . . . .141 PJ1530 . . . . . . . . . . . . . . . .141 PJ1535 . . . . . . . . . . . . . . . .141 PJ1545 . . . . . . . . . . . . . . . .141 PJ712 . . . . . . . . . . . . . . . . .141 PJ713 . . . . . . . . . . . . . . . . .141 PJ714 . . . . . . . . . . . . . . . . .141 PJ715 . . . . . . . . . . . . . . . . .141 PJ716 . . . . . . . . . . . . . . . . .141 PJ718 . . . . . . . . . . . . . . . . .141 PJ720 . . . . . . . . . . . . . . . . .141 PJ722 . . . . . . . . . . . . . . . . .141 PJ762 . . . . . . . . . . . . . . . . .141 PJ764 . . . . . . . . . . . . . . . . .141 PJ765 . . . . . . . . . . . . . . . . .141 PJ766 . . . . . . . . . . . . . . . . .141 PJ768 . . . . . . . . . . . . . . . . .141 PJ770 . . . . . . . . . . . . . . . . .141 PJ772 . . . . . . . . . . . . . . . . .141 PXP-532003 . . . . . . . . . . . .130 PXP-532004 . . . . . . . . . . . .130 PXP-A00006 . . . . . . . . . . .130

600 mm Products

R
RAC-0B0748 . . . . . . . . . . .114 RAC-EGK300 . . . . . . . . . . .132 RAC-EGK450 . . . . . . . . . . .132 RAC-EGK600 . . . . . . . . . . .132 RAC-MX0615 . . . . .16,26,133 RAC-MX0616 . . . . .16,26,133 RINST-FLR . . . . . . . . . .137,140

100571

S
SFK-122150 . . . . . . . . . . . .132 SFK-122300 . . . . . . . . . . . .132 SHD-0007 . . . . . . . . . . . . .137 SHD-0051 . . . . . . . . . . . . .137 SHD-0323 . . . . . . . . . . . . .137 SHD-0424 . . . . . . . . . . . . .137 SHD-0512 . . . . . . . . . . . . .137 SHD-HR-28 . . . . . . . . . . . .137 SHD-HR-43N . . . . . . . . . . .140 SHD-HR-44N . . . . . . . . . . .140 SHD-HR-55 . . . . . . . . . . . .137 SHD-HR-85 . . . . . . . . . . . .140 SHD-HR-91 . . . . . . . . . . . .140 SHD-HR-92 . . . . . . . . . . . .140 SHD-HR-93 . . . . . . . . . . . .140 SHD-W-0001 . . . . . . . . . . .137 SHD-W-0005 . . . . . . . . . . .137

10/03

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

188

Index
STC-11B . . . . . . . . . . . . . . .121 STC-12B . . . . . . . . . . . . . . .121 STC-13B . . . . . . . . . . . . . . .121

V
VAM-6PB2 . . . . . . . . . . . . . .59 VAM-6PB4 . . . . . . . . . . . . . .59 VAM-6PB5 . . . . . . . . . . . . . .59 VAM-6PB7 . . . . . . . . . . . . . .59 VAM-6PB9 . . . . . . . . . . . . . .59 VAM-A6PB2 . . . . . . . . . . . . .59 VAM-A6PB5 . . . . . . . . . . . . .59 VAM-A6PB8 . . . . . . . . . . . . .59 VAM-BLNK . . . . . . . . . . . . . .59 VAM-D6PB7 . . . . . . . . . . . . .59 VAM-D6PB9 . . . . . . . . . . . . .59 VI-124-1394 . . . . . . . . . . .174

T
TNC-1 . . . . . . . . . . . . . . . .120 TNC-2 . . . . . . . . . . . . . . . .120 TNC-3 . . . . . . . . . . . . . . . .120 TNC-4 . . . . . . . . . . . . . . . .120 TNC-7 . . . . . . . . . . . . . . . .120 TPA-03 . . . . . . . . . . . . . . . .109 TPA-05 . . . . . . . . . . . . . . . .109 TPA-10 . . . . . . . . . . . . . . . .109 TPA-15 . . . . . . . . . . . . . . . .109 TPA-20 . . . . . . . . . . . . . . . .109 TPA-25 . . . . . . . . . . . . . . . .109 TPA-30 . . . . . . . . . . . . . . . .109 TPA-40 . . . . . . . . . . . . . . . .109 TPA-50 . . . . . . . . . . . . . . . .109 TPC-15 . . . . . . . . . . . . . . . .107 TPC-20 . . . . . . . . . . . . . . . .107 TPC-25 . . . . . . . . . . . . . . . .107 TPC-30 . . . . . . . . . . . . . . . .107 TPC-40 . . . . . . . . . . . . . . . .107 TPC-50 . . . . . . . . . . . . . . . .107 TPC-60 . . . . . . . . . . . . . . . .107 TPC-75 . . . . . . . . . . . . . . . .107 TPC-90 . . . . . . . . . . . . . . . .107 TPC-100 . . . . . . . . . . . . . . .107 TPC-125 . . . . . . . . . . . . . . .107 TPCDS-BBE-2 . . . . . . . . . . .107 TPM-03 . . . . . . . . . . . . . . .109 TPM-04 . . . . . . . . . . . . . . .109 TPM-05 . . . . . . . . . . . . . . .109 TPM-06 . . . . . . . . . . . . . . .109 TPM-07 . . . . . . . . . . . . . . .109 TPM-08 . . . . . . . . . . . . . . .109 TPM-10 . . . . . . . . . . . . . . .109 TPM-12 . . . . . . . . . . . . . . .109 TPM-15 . . . . . . . . . . . . . . .109 TPM-20 . . . . . . . . . . . . . . .109 TPM-25 . . . . . . . . . . . . . . .109 TPM-30 . . . . . . . . . . . . . . .109 TPMDS-E . . . . . . . . . . . . . .109 TPMDS-M . . . . . . . . . . . . .109 TT1000 . . . . . . . . . . . . . . .121

600 mm Products

W
WD-1 WD-2 WD-3 WT-2 . . . . . . . . . . . . . . . . .121 . . . . . . . . . . . . . . . . .121 . . . . . . . . . . . . . . . . .121 . . . . . . . . . . . . . . . . .121

10/03

100571

U
UEGP-7PW . . . . . . . . . . . . . .47

www.adc.com

+32-2-712-65-00

+32-2-712-65-42

189

Web Site: www.adc.com


From North America, Call Toll Free: 1-800-366-3891 Outside of North America: +1-952-938-8080 Fax: +1-952-917-3237 For a listing of ADCs global sales office locations, please refer to our web site.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer 100571 10/03 Revision 2002, 2003 ADC Telecommunications, Inc. All Rights Reserved

You might also like