You are on page 1of 4

Outdoor solutions for large-scale PV plants

INVERTER

ULTRA-700.0-TL ULTRA-1050.0-TL ULTRA-1400.0-TL

MV COMPARTMENT

ULTRA-MV-700.0 ULTRA-MV-1050.0 ULTRA-MV-1400.0 ULTRA-MV-1750.0 ULTRA-MV-2100.0 ULTRA-MV-2450.0 ULTRA-MV-2800.0

Features
High performance utility grade inverter for large PV installations with 98.7% efficiency Outdoor enclosure for unrestricted use under any environmental conditions Passive liquid cooling with total segregation of internal compartments assuring an extended maintenance cycle Modular layout with multiple MPPTs and reduced susceptibility to a single fault Maximum input voltage up to 1100 Vdc, high design
flexibility and reduced AC losses thanks to the 690Vac output voltage

ULTRA INVERTER

LV/MV station specifically designed for ULTRA inverters Easy to deploy and install thanks to very low weight and compact dimensions Easy to maintain: readily accessible and replaceable components High efficiency thanks to low losses LV/MV transformer Wide power range for any kind of applications

ULTRA MV COMPARTMENT

AURORA PLUS

ULTRA STATION
1

ULTRA STATION

STANDARD configurations

single inverter
ULTRA-MV-700.0
AUX LV/LV

MULTIPLE INVERTERS
ULTRA-MV-1750.0*
AUX LV/LV

MV SWITCHGEAR LV DISTRIBUTION PANEL UPS

MV SWITCHGEAR 700 kVA LV/MV LV DISTRIBUTION PANEL UPS

1050 kVA LV/MV

700 kVA LV/MV

ULTRA-700.0-TL

ULTRA-1050.0-TL

ULTRA-700.0-TL

ULTRA-MV-1050.0
AUX LV/LV

ULTRA-MV-2100.0
AUX LV/LV

MV SWITCHGEAR LV DISTRIBUTION PANEL UPS

MV SWITCHGEAR 1050 kVA LV/MV LV DISTRIBUTION PANEL UPS

2100 kVA LV/MV

ULTRA-1050.0-TL

ULTRA-1400.0-TL

ULTRA-700.0-TL

ULTRA-MV-1400.0
AUX LV/LV

ULTRA-MV-2450.0*
AUX LV/LV

MV SWITCHGEAR LV DISTRIBUTION PANEL UPS

MV SWITCHGEAR 1400 kVA LV/MV LV DISTRIBUTION PANEL UPS

1400 kVA LV/MV

1050 kVA LV/MV

ULTRA-1400.0-TL

ULTRA-1400.0-TL

ULTRA-1050.0-TL

ULTRA-MV-2800.0*
AUX LV/LV

MV SWITCHGEAR LV DISTRIBUTION PANEL UPS

1400 kVA LV/MV

1400 kVA LV/MV

* also provided with a single LV/MV transformer when PV modules do not require one pole (either positive or negative) to be grounded.

ULTRA-1400.0-TL

ULTRA-1400.0-TL

AURORA PLUS

PARAMETER
ULTRA-700.0-TL Input Side MPPT Input Range (VMPPTmin,r...VMPPTmax,r) MPPT Input Range (VMPPTmin,f...VMPPTmax,f) at Full Power Absolute Maximum Input Voltage (Vmax,abs) Number of Independent MPPT Multi-Master Number of Independent MPPT Master/Slave Number of Independent MPPT Multi-Master/Slave Maximum Combined Input Current (Idcmaxc) Maximum Input Current for Each Module (Idcmax,m) Number of DC Inputs Pairs DC Connections Type Input Protection Reverse Polarity Protection Input Over Voltage Protection - Varistor Photovoltaic Array Isolation Control Fuse Size for Each Input Pair Output Side AC Grid Connection (Vacmin...Vacmax) Rated Power (Pac,r) Rated Grid Voltage (Vac,r) AC Voltage Range (Vacmin...Vacmax) Maximum Output Current (Iac,max) Rated Frequency (fr) Frequency Range (fmin... fmax) Nominal Power Factor (Cosphiac,r) Total Harmonic Distortion AC Connection Type Output Protection Anti-Islanding Protection Output Overvoltage Protection - Varistor AC Circuit Breaker Night Time Disconnect Operating Performance Maximum Efficiency (max) Weighted Efficiency (EURO/CEC) Stand-by Consumption/Night-time power loss Auxiliary Supply Auxiliary Supply Consumption Auxiliary Supply Consumption without Cooling Inverter Switching Frequency Communication Wired Local Monitoring 1 x RS485 (inc.) Remote Monitoring AURORA String Combiner 1 x RS485 (inc.) User Interface Environmental Ambient Temperature Range Relative Humidity Noise Emission Maximum Operating Altitude without Derating Physical Environmental Protection Rating Cooling Required Air Cooling Flow Dimension (H x W x D) Weight Weight of the module Safety Transformer Marking Safety and EMC Standard Grid Standard
1 2

ULTRA INVERTER
ULTRA-1050.0-TL 350...950 V 500...900 V 1100 V 3 Not applicable 2 1440 A + 720 A 720 A 18 18 x 50mm2 (M8) Yes, via input breaker 6 for each module According to local standard with alarm 125 A / 1100 V Three phase 1050 kW 690 Vac / PE 621...759 Vac 1 876 A 50/60 Hz 47...53 / 57...63 Hz 2 < 0.995 (adj. 0.90) < 3% (@ Pac,r) 3 x 240 mm2 (M12) According to local standard Yes 3 x 630 A / 40 kA Yes 98.7% 98.2% / 98.2% < 135 W 3 x 400 Vac / N /PE < 0.40 % of Pac,r < 0.08% of Pac,r 9 kHz PVI-USB-RS485_232 (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-STRINGCOMB (opt.) TFT LCD 5.7 -20...+ 60C/-4...140F with derating above 50C/122F -40...+ 60C/-40...140F with derating above 50C/122F (opt.) 0...100% condensing < 78 dB(A) @ 1 m 1000 m / 3280 ft IP 65 Passive liquid and air forced Not applicable 2938mm x 3700mm x 1520mm / 115.7 x 145.7 x 59.9 < 2500 kg / 5521 lb < 50 kg / 100 lb ULTRA-1400.0-TL

2 1 1 1440 A 12 12 x 50mm2 (M8)

4 Not applicable 2 1440 A + 1440 A 24 24 x 50mm2 (M8)

4 for each module

8 for each module

700 kW

1400 kW

590 A

1168 A

2 x 240 mm2 (M12)

4 x 240 mm2 (M12)

< 90 W < 0.35% of Pac,r < 0.08% of Pac,r

< 180 W < 0.65 % of Pac,r < 0.08% of Pac,r

2938mm x 3000mm x 1520mm / 115.7 x 118.1 x 59.9 < 2000 kg / 4409 lb

2938mm x 4400mm x 1520mm / 115.7 x 173.2 x 59.9 < 3500 kg / 7716 lb

No 3 CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 Enel Guideline, BDEW, FERC 661

The AC Voltage Range may vary depending on specific country grid standard The Frequency Range may vary depending on specific country grid standard 2 Optionally provided within external station

AURORA PLUS

PARAMETER
Standard Configurations Available Product Variants -IT version for Italy -DE version for Germany Electrical Input Voltage -IT version Output Voltage -DE version LV Distribution Panel

ULTRA MV COMPARTMENT
ULTRAMV-700.0
1 x ULTRA-700.0-TL

ULTRAMV-1050.0
1 x ULTRA-1050.0-TL

ULTRAMV-1400.0
1 x ULTRA-1400.0-TL

ULTRAMV-1750.0
1 x ULTRA-1050.0-TL + 1 x ULTRA-700.0-TL

ULTRAMV-2100.0
1 x ULTRA-1400.0-TL + 1 x ULTRA-700.0-TL

ULTRAMV-2450.0
1 x ULTRA-1400.0-TL + 1 x ULTRA-1050.0-TL

ULTRAMV-2800.0
2 x ULTRA-1400.0-TL

MV Switchgear LV/MV Transformer Type -IT/DE version Cooling Class -IT/DE version Floating PV field

690 Vac 3 x 15/20 kV 3 x 10...20 kV LV magnetothermic circuit breaker (suitable for automatic reset) Insulation control device LV energy meter (optional) LV interface protection device (optional) Auxiliary LV distribution for ancillary services and ULTRA inverters Air/Gas insulated Single/Double MV feeder Optional Delivery Cabinet configuration (suitable for direct connection to the MV distribution grid) 3 Phase Oil Filled / Dry ONAN (for oil filled transformer), air cooled (for dry transformer)

Nominal Power/ Number of Secondary Windings

1 x 700kVA / 1

1 x 1050kVA / 1

1 x 1400kVA / 1

1 x 1750kVA / 1

1 x 2100kVA / 1

1 x 2450kVA / 1

1 x 2800kVA / 1

Grounded PV field

1 x 700kVA / 1

1 x 1050kVA / 3

1 x 1400kVA / 2

1 x 700kVA / 1 + 1 x 1050kVA / 3 1 x 10kVA, dry type 2kVA

1 x 2100kVA / 3

1 x 1050kVA / 3 + 1 x 1400kVA / 2

2 x 1400kVA / 2

Auxiliary Transformer UPS Environmental Ambient Temperature Range Relative Humidity Maximum Operating Altitude without derating Physical Construction Mounting Environmental Protection Rating
1

-20...+60C 0...95% non condensing 1000 m1 Sandwich Technology Concrete platform or Pier-Mount IP54

Due to the ULTRA inverter

www.power-one.com
Power-One - Renewable Energy Worldwide Sales Offices Country North America France Germany Italy Spain United Kingdom Dubai Australia China (Beijing) China (Hong Kong) Singapore