You are on page 1of 38

Submersible Pump in Discharge Tube

Amacan S
60 Hz

Type Series Booklet

Legal information/Copyright
Type Series Booklet Amacan S
KSB Aktiengesellschaft Halle
All rights reserved. Contents provided herein must neither be distributed, copied, reproduced, edited
or processed for any other purpose, nor otherwise transmitted, published or made available to a third
party without KSBs express written consent.
Subject to technical modification without prior notice.
KSB Aktiengesellschaft Frankenthal 18.01.2012

Contents

Contents
Water Applications: Water Transport ............................................................................................................. 4
Submersible Pump in Discharge Tube .................................................................................................................... 4
Amacan S ...................................................................................................................................................... 4
Main applications .............................................................................................................................. 4
Fluids handled ................................................................................................................................... 4
Operating data .................................................................................................................................. 4
Designation ....................................................................................................................................... 4
Design details .................................................................................................................................... 4
Materials ............................................................................................................................................ 4
Coating/preservation ........................................................................................................................ 5
Product features / customer benefits ............................................................................................... 5
Acceptance tests / warranties ........................................................................................................... 5
Design and selection information .................................................................................................... 5
Table of fluids handled ..................................................................................................................... 6
Related documents ........................................................................................................................... 6
Material variants ............................................................................................................................... 6
Data to be indicated in the purchase order .................................................................................... 7
Data to be indicated for ordering a support rope .......................................................................... 7
Technical data ................................................................................................................................... 8
General assembly drawing ............................................................................................................... 9
Performance chart ........................................................................................................................... 11
Characteristic curves ........................................................................................................................ 12
Dimensions ...................................................................................................................................... 25
Installation types ............................................................................................................................. 33
Flow-straightening vane (optional accessory) ............................................................................... 34
Pump with support rope and turnbuckle in the discharge tube ................................................. 35
Discharge tube cover with cable gland ......................................................................................... 36
Scope of supply ............................................................................................................................... 37

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Designation
Example: Amacan S 1000-655 / 25O 10 UT G2
Key to the designation
Code

Amacan S

Amacan
S

Possible
additions

1000

655

250
10

6 poles
8 poles
10 poles
12 poles
UT
UA
G2
G3

UT
G2

Description
Type series
Impeller type, e.g. S = mixed
flow impeller
Nominal diameter of the
discharge tube [mm]
Nominal impeller diameter
[mm]
Motor size
Number of motor poles

Motor version ( Page 8)


Material variant ( Page 6)

Design details
Design
Fully floodable submersible pump in discharge tube
(submersible motor pump)
Not self-priming

Main applications
Irrigation and drainage pumping stations

Close-coupled design

Stormwater pumping stations

Single-stage

Raw and clean water pumps in water works

Vertical installation

Cooling water pumps in power stations and in industry


Industrial water supply

Impeller type
Open or closed mixed flow impeller

Water pollution and flood control


Dock and sluice pumps

Shaft seal

Aquaculture

Two bi-directional mechanical seals in tandem


arrangement, with liquid reservoir

Fluids handled

Leakage chamber

Waste water

Bearings

River water

Grease-packed rolling element bearings

Stormwater
Activated sludge

Drive

Seawater

Three-phase asynchronous squirrel-cage motor

Operating data
Characteristic
Flow rate
Head
Motor rating

H
P2

Value
up to 50,000 US gpm
[3,000 m3/h]
up to 98 ft [30 m]
up to 500 hp [370 kW]

Temperature of fluid
handled1)

up to 104 F [40 C]

1)
2)

Materials
Parts/components
Pump casing
Motor housing
Shaft
Impeller
Casing wear ring
Nuts, bolts and screws

Higher temperatures on request


Optional: material variant for seawater available on request.

Amacan S

Material2)
Gray cast iron A48 Class 30 B
Gray cast iron A48 Class 40 B
Stainless steel 420 or 431
Duplex stainless steel
Stainless steel
Stainless steel

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Coating/preservation
Paint coat

pump and motor we recommend selecting a motor size which


provides sufficient power reserves!

Surface treatment: SA 2 1/2 (SIS 055900) AN 1865

Recommended minimum reserves4)

Primer: Primer for raw castings 0.00098 inch [0.025 mm] to


0.00138 inch [0.035 mm]

Required pump
input power

Top coat: Environmentally-friendly KSB standard coating


(RAL 5002)

< 30 kW
> 30 kW

Motor power reserve


Mains operation
With frequency
inverter
10 %
15 %
5%
10 %

Special coating

Intake chamber

Available on request (surcharge and longer delivery period


apply).

Determine the min. water level t1min (see diagram in general


arrangement drawing):
The min. water level t1min is the water level required in the
pump's suction chamber to ensure:

Product features / customer benefits


Efficient use of power thanks to three-phase motor and
optimum motor cooling by fluid handled.
Easy to install as pump's own weight ensures selfcentering seating in the discharge tube, and an O-ring
seals it. Quick to install or remove without any additional
anchoring or anti-rotation elements.
Slim motor minimizes discharge tube flow losses.
High reliability provided by bearing temperature
monitoring, vibration sensor, thermal motor protection,
leakage sensors in the motor and connection space, and
leakage monitoring of the mechanical seal system.
Low-vibration hydraulic system; inlet ribs and optimized
bellmouth for vortex-free inflow.

that there is a sufficient liquid cover above the hydraulic


system (impeller) (shown in diagram depending on pump
size)
that the pump does not draw in air-entraining vortices
(shown in diagram depending on flow rate)
that there is no cavitation in the hydraulic system (check
against the NPSHpump value indicated in the technical
literature!) .The following conditions must be met:
NPSHsystem > NPSHpump + safety allowance
NPSHsystem = 10.0 + (t1 - t3 - h7/2)
Safety allowance:
up to Qopt 0.5 m
greater than Qopt 1.0 m

Head (H)
Acceptance tests / warranties
Performance test
Each pump is subjected to a performance test to KSB
Standard ZN 56525.
The operating data is guaranteed to ISO 9906/2 or
Hydraulic Institute, Level B as a standard.3)
Acceptance tests to ISO/DIN or a comparable standard are
available against a surcharge.
Quality is assured by means of an audited and certified
quality assurance system to DIN EN ISO 9001.

Design and selection information


Information for pump selection
The guaranteed point of submersible pumps in discharge tubes
is measured at a head 0.5 m above the motor (DIN 1184). The
documented characteristic curves refer to this data. This must
be taken into account when calculating system losses. The
indicated heads and performance data apply to pumped fluids
with a density =1 kg/dm3 and a kinematic viscosity of up to
20 mm2/s.
The pump input power must be matched to the density of the
fluid handled:
P2req = fluid [kg/dm3] x P2docu

The total head of the pump is composed as follows:


H = Hstatic + HV
Hstatic (static head)
Without discharge elbow difference between the
suction-side water level and the overflow edge
With discharge elbow difference between the suctionside water level and the discharge-side water level
HV (losses in the system)
Starting 0.5 m downstream of the pump: e.g. pipe friction,
elbows, swing check valves, etc.

Losses by inlet, riser and elbow


Losses are caused by the inlet, riser and elbow (or free
discharge).
Losses in the riser are taken into account in the
documented characteristic curves up to the indicated
reference level (0.5 m above the motor).
Inlet and elbow losses are system losses and must be taken
into account for selection.
For information on structural requirements, pump
installation and pump sump design refer to the KSB knowhow brochure "Planning information: Amacan
submersible pumps in discharge tubes" (ref. No. 0118.55).

The operating point with the largest pump input power is


decisive for the operating range of the motor. Always indicate
the QH data when placing an order. To compensate the
unavoidable tolerances of the characteristic curves of system,

3)
4)

Hydraulic Institute, Level A available on request


If larger reserves are stipulated by local regulations or are required to compensate for uncertain factors in system
calculations, these larger reserves must be provided!

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Table of fluids handled

Size

The table below for your guidance is based on KSB's longstanding experience The data are standard values and are not
to be considered as generally binding recommendations. More
detailed advice is available from our specialist department in
Halle. Make use of our laboratory's wealth of experience when
selecting materials.

850-550

1 1/2

40

/2

15

2
2

Information and recommendations for fluids handled

900-600
900-615
900-620

1 1/2

50
50
40

1
1
1
/2

25
25
15

1000-655

2 1/2

60

25

1300-820

2 1/2

60

25

Fluid handled5) not containing


stringy material
Waste water (without long
fibers and large solid particles)
Surface water
(stormwater, river water)
Activated sludge
Seawater6)

Notes, recommendations

800-535

Coarse screen
[inch]
[mm]
1 1/2
40

Fine screen
[inch]
[mm]
1
/2
15

Pre-screen with fine screen.

Related documents

Pre-screen.

General Arrangement Drawings 1589.396


Motor Data Booklet 1589.566

Max. dry substance 2 %


Material variant G3 up to
t = 77 F [25 C]7)

Planning Information 0118.55

Space between screen bars


Size

Coarse screen

Fine screen8)
[inch]
[mm]
1
/2
15

650-364 / -365

[inch]
1 1/2

[mm]
40

650-404 / -405

1 1/2

40

/2

15

800-505

1 /2

40

/2

15

Material variants
Standard range (up to approximately 500 hp)
Part No.

Description

G2

101
138
233

Pump casing
Bellmouth
Open counter-clockwise impeller
Closed counter-clockwise impeller
Bearing housing / bearing bracket
Bearing cover
O-ring

A 48 Class 40 B
A 48 Class 30 B
A 890 CD 4 MCu
A 890 CD 4 MCu
A 48 Class 40 B
A 48 Class 40 B

Mechanical seal
pump end
Mechanical seal
motor end
Casing wear ring
Bail

SiC/SiC (NBR bellows10), Viton FPM11))

350/330
360
412
433

502
571
811
812
818
82-5
834

Motor housing
Motor housing cover
Shaft (rotor)
Adapter
Cable gland
Gland housing
Various
Screws/bolts
99-16
Anode
Other materials on request.

5)
6)
7)
8)
9)
10)
11)
12)

G39)

NBR10) (FKM11))

Carbon/SiC
Stainless steel (A 276 Type 316)
A 536: 60-40-18/A 284 B12)
A 48 Class 40 B
A 48 Class 40 B
A 276 Type 420
A 48 Class 40 B

A 48 Class 40 B
Stainless steel

A 276 Type 431

Zn

Fluids to be pumped which are not listed in this table usually require higher-grade materials. Contact KSB.
Use of anodes required (efficiency reduced by 2 % to 3 %); anode to be checked every 6 to 12 months
For t > 25 C contact KSB (stainless steel variant)
Fine screens must be used for high pollution loads.
Pump set with cathodic protection (anodes to be checked every 6 to 12 months) and top coat of 0.0098 inch [250 m]
Nitrile butadiene rubber (Perbunan)
FPM fluoro rubber variant available as an option against a surcharge
A 535: 60-40-18 for motors: 858 ... 1608.TG, 6010 ... 12010.TG; all other motors A 284 B

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Data to be indicated for ordering a support rope

Comparison of materials
Similar to EN
JL 1030
JL 1040
1.4517
1.4021
1.4057
NBR
FPM
JS 1030
S235JRG2

ASTM material
A 48 Class 30 B
A 48 Class 40 B
A 890 CD 4 MCu
A 276 Type 420
A 276 Type 431
NBR
FKM
A 536: 604018
A 284 B

Always define dimension "L" when ordering a support rope


to allow the correct length to be determined! The lifting
height of the crane must be taken into account when
ordering a support rope! This determines the number of
lifting rings required for installing the pump in or removing it
from the pump sump.
1

Notes on material
Duplex stainless carbon steel (1.4517 or technically equivalent
material)
Carbon steel is resistant to cavitation, has excellent strength
values and is used for high circumferential speeds. An excellent
resistance to pitting corrosion makes ferritic-austenitic stainless
steel a popular choice for pumping acidic waste water
containing large amounts of chloride as well as seawater and
brackish water. Thanks to its good chemical resistance, also e.g.
against waste water containing phosphorous and sulphuric
acid, this material is used in a wide range of applications in the
chemical industry and process engineering. Pumps made of
duplex stainless steel have a very long service life, even when
handling brines, chemical waste water (pH 112), gray waste
water and landfill leachate.

Data to be indicated in the purchase order


Designation of the pump (see section Designation)
Flow rate Q
Head Htotal
Type and temperature of fluid handled
Voltage, frequency, starting method, cable length
Required accessories
For a support rope indicate dimension "L", the
number of lifting rings (depending on the lifting
height of the hoisting tackle) as well as the elevations
and type of installation.

For discharge tubes indicate all required elevations


and the type of installation.
For flow-straightening vanes indicate the type of
installation and whether the design is with or without
suction umbrella.
Quantity and language of operating manuals

1 Suspension arrangement attached to cover (or cross beam


for BU/BG)
2 Optional lifting ring
3 Lower edge of pump sump = lower edge of pump
Data to be indicated in the purchase order:
Length L = ______________________________ mm
Length L = ______________________________ inch
(suspension arrangement up to lower edge of the sump)
and number of lifting rings: ________________ lifting rings
The rope as accessory can also be supplied with lifting rings
and support ( Page 35) as an option. The basic version is
supplied without lifting rings.

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Technical data
Material variant (G2, G3)
Motor version
6 poles
8 poles
10 poles
12 poles
Version U..
Motor
Starting method
Voltage

UAG
26 6 ... 120 6

DOL, soft starter, frequency inverter

33 ft [10 m]15)
Absolutely watertight

Cable entry
Sealing elements
Elastomer seals

Mechanical seal leakage


Vibration transducer
Coating

Nitrile butadiene rubber NBR 16)


Bellows-type mechanical seal
PTC in the winding
Pump end PT100
Pump end PT10017)
Motor end PT100
Electrode monitoring the winding for Electrode monitoring the winding and connection space
leakage
for leakage
Float switch in leakage area

Option: internal vibration transducer

Installation
Maximum temperature of fluid handled
G2
G3
Tests
Hydraulic system

13)
14)
15)
16)
17)
18)
19)

Optional: 380 V, 575 V


Optional: EMC cable
Optional: up to 165 ft [50 m]
Optional: Viton = fluoro rubber FPM
Optional: motor end PT 100
Optional: 0.0098 inch [250 m]
Optional: Hydraulic Institute, Level A

Amacan S

DOL, soft starter, frequency inverter or star-delta

Rubber-sheathed cable, see Motor Data Booklet14)

Length

Leakage inside the motor

310 10
250 12 ... 370 12

460 V13)
Cooled by surrounding fluid
Max. 40 ft [12 m]

Cooling
Immersion depth
Power cable

Shaft seal
Monitoring
Motor temperature
Bearing temperature

UTG

75 8 ... 120 8
85 8 ... 160 8
205 8 ... 290 8

60 10 ... 120 10
200 10 ... 250 10

190 12
Standard, not explosion-proof

Environmentally-friendly KSB standard, color RAL 5002)18)


See General Arrangement Drawings
104 F [40 C]
77 F [25 C]
KSB Standard (ZN 56525)19)

Water Applications: Water Transport


Submersible Pump in Discharge Tube

General assembly drawing


Amacan S 650-364 / 365
Amacan S 650-404 / 405
Amacan S 800-505
Motor version: UAG

V
571

412

412

82-5

834

812

350

412

811
(80--1)

818

360

412
V

101
350

433

412

502
233
138

0W 383 890-00

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 800-535
Amacan S 850-550
Amacan S 900-600 / 615 / 620
Amacan S 1000-655
Amacan S 1300-820
Motor version: UTG

V
412

834
812

571

82-5

412

330

811
(80--1)

233
502
138

818
Design:
closed impeller

412

360
V

350
101
350

433

412
502
233
138

UG 13169994

List of components
Part No.
101
138
233
350 / 330
360
412

10

Description
Pump casing
Bellmouth
Open counter-clockwise impeller
Closed counter-clockwise impeller
Bearing housing / bearing bracket
Bearing cover
O-ring

Amacan S

Part No.
433
502
571
811
812
82-5
834

Description
Mechanical seal
Casing wear ring
Bail
Motor housing
Motor housing cover
Adapter
Cable gland

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Performance chart
Q [ m /h]

1000
200

200

300

400

2000

4000

3000
Q [l/s]

500

10000

5000
2000

1000

20000

3000

4000

5000

50
40

B
...-720
8p

100

30

...-620 8p

A
A

...-600
8p

...-550
8p

50
40

...-404 6p

...-405 6p

...-810
10p

20

...-975 12p

...-615

...-655
10p

...-535

...-365 6p

8p

8p

10

A
...-820 12p

...-364 6p

20

...-725
10p

...-505
8p

30

...-550
10p

5
4

10

3
H [m]

H
[ft]

5
3000

4000
3000

Q [US.gpm]

5000
4000

5000

Standard range

20000

10000

Q [IM.gpm]

10000

30000
20000

40000
30000

50000
40000

100000 120000
50000

Special range on request

Amacan S

11

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Characteristic curves
Amacan S 650-364
1180 rpm20)
600

800

1000

200
40

300

Q [l/s]

70

60
70
60
70

75
75

78

400

460

[%]

80
82

78

80

82

81.7

78

78

78

78

75

75

76.3

H [m

80

80

79.4

70
75

10

82.9

75

60

20

1600

Qmin

60

H [ft]

Q [m3/h] 1400

1200

75

75
70

70

70
70

60

60

5
328

338

322
306

0
2600
28

3000

2200

4000

5000

3000

4000

Q [US.gpm] 6000

7000

Q [IM.gpm] 5000

NPSH3% [ft]

0
7400

6000

306

322

328 338

NPSH3% [m]

20

5
14
50
P [hp]
40

P [kW]

338
328

20

322

20
306

10
10
2600

3000

4000

5000

Q [US.gpm] 6000

7000

7400

K42980

Free passage

1 " (39.0 mm)

Rated power P2 and mass moment of inertia J 21)


Size

Rated power P2

650-364 / 26 6 UAG
650-364 / 30 6 UAG
650-364 / 50 6 UAG

20)
21)

12

[hp]
33
45
63

[kW]
25
35
47

Mass moment of inertia J


[kgm2]
0.67
0.67
0.68

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density of 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 650-365
1180 rpm22)
800
50

1000

220

1200

1400 Q [m3 /h] 1600

300

400

1800

2000

500

Q [l/s]

2100
580

Qmin
70

40

70
70

H [ft]

75
75

78
78

80

[%]

82

80

83.9

82

75

82.6

78
80
70

82
80.2

10
82
80

80

75

20

H [m]

78

77.2

80

75

75
75

78

78

75
70

70

70

363

70

352
346
329

0
3400

4000

3000

5000
4000

6000
5000

7000 Q [US.gpm] 8000


Q [IM.gpm] 6000

9000
7000

30

346

352

0
9400
7800
9

363

329

NPSH3% [ft]

NPSH3% [m]

20
5

16
80

50

P [hp]
50

363

P [kW]

352
346
329

10
3400

10
4000

5000

6000

7000 Q [US.gpm] 8000

9000

9400

K42981

Free passage

1 " (39.0 mm)

Rated power P2 and mass moment of inertia J23)


Size

Rated power P2

650-365 / 30 6 UAG
650-365 / 50 6 UAG
650-365 / 65 6 UAG

22)
23)

[hp]
45
63
80

[kW]
35
47
60

Mass moment of inertia J


[kgm2]
0.67
0.68
0.77

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density of 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

13

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 650-404
1180 rpm24)
600

800

170

70

1000

200

250

60
75

300

1200
l/s

1400
350

1550
400

440
20

Qmin

75

H [ft]

Q [m3/h]

78

[%]

80
81.3

78

H [m]

80
75

40

80

80.6

78

80

78

79.8
78

75

78

75

10
380

75

362
346

20
2600
30

3000

2200

3500

4000

4500

3000

5000
4000

Q [US.gpm]
Q [IM.gpm]

6000

6500

7000

5000

5800
380

NPSH3% [ft]
20

8
NPSH3% [m]

362
346

10
80
P [hp]

380

P [kW]

60
40

362

40
30
2600

346

25
3000

3500

4000

4500

5000

Q [US.gpm]

6000

6500

7000
K42982

Free passage

1 5/8" (42.0 mm)

Rated power P2 and mass moment of inertia J25)


Size

Rated power P2

650-404 / 30 6 UAG
650-404 / 50 6 UAG
650-404 / 65 6 UAG

24)
25)

14

[hp]
45
63
80

[kW]
35
47
60

Mass moment of inertia J


[kgm2]
0.87
0.88
0.97

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density of 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 650-405
1180 rpm26)
1000
300

400

80
75

70

80

75

80

60
75

70

40

Q [l/s]

75

80

20

84

82

84.4

84

83.7

82

80
80

82

81.6

H [m]

82
82

83.4

H [ft]

600

[%]

82

80

2000

500

Qmin

70

70

Q [m 3/h]

1500

75

75

80
80

70

70

75
70

20

10

70

75

401

415

387
372

0
4000

5000
4000

Q [US.gpm]

7000

8000

5000 Q [IM.gpm] 6000

9000
7000

8000

9000
20

401

387

50

415

372

NPSH 3%[ft]

0
11000

10000

NPSH 3%[m]
5

10
140

100
415

100

P [kW]

401

P [hp]
50

387

50
30
4000

372

5000

Q [US.gpm]

7000

8000

9000

10000

11000
K42983/1

Free passage

1 5/8" (42.0 mm)

Rated power P2 and mass moment of inertia J27)


Size

Rated power P2

650-405 / 50 6 UAG
650-405 / 65 6 UAG
650-405 / 80 6 UAG
650-405 / 100 6 UAG
650-405 / 120 6 UAG

26)
27)

[hp]
63
80
100
125
145

[kW]
47
60
75
95
110

Mass moment of inertia J


[kgm2]
0.99
1.09
1.21
1.32
1.46

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density of 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

15

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 800-505
880 rpm28)
1200
75

1500

320

400
75

70
70

75

75

40

80
80

75

H [ft]
70

500

600

Qmin

70

60

Q [m3/h]

2000

80

82

82

80

84
84.8

82

82

82.4

Q [l/s]

700

840

20

H [m]

84
82

82

84

80

80

82

80

82

75

75

80

75
70

70

20

10

70

70

75

489

500

474
448

10
5000
50
NPSH3% [ft]
40

800

85.6
84

84.1

3000

[%]

84

84

2500

6000
4500

7000

8000

9000

6000

Q [US.gpm] 11000
8000

12000

Q [IM.gpm]

13000 13600

10000

11000

489

500

474

NPSH3% [m]
10

448

20

150
P [hp]

500

P [kW]
100

489

100
474
448

60
5000

6000

7000

8000

9000

Q [US.gpm] 11000

50
12000

13000 13600
K42984

Free passage

2 " (57.0 mm)

Rated power P2 and mass moment of inertia J29)


Size

Rated power P2

800-505 / 75 8 UAG
800-505 / 100 8 UAG
800-505 / 120 8 UAG

28)
29)

16

[hp]
100
135
165

[kW]
75
100
125

Mass moment of inertia J


[kgm2]
3.03
3.34
3.56

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density of 1 kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 800-535
880 rpm30)
2000

3000
600

60

4000

1000

Q [l/s]

800

Qmin

70

75

70

75

70

40

Q [ m3 /h]

75

78
78

78

80

80
80

70

75

1200

1350

[%]

82

H [m]

84

82

85.7
84.1
84

82

84

83.3

H [ft]

4800

82

78

80

79.8
78

20

82

82
80
78

80

78
75

75

75
70

70

70

75

10

78

531

70

520

504
485

0
8000
36
NPSH3%[ft]

7000

10000
8000

12000

14000

16000

Q[US.gpm] 18000

12000 Q[IM.gpm] 14000

10000

16000

485

30

0
22000

20000

504

18000

520

531

10
NPSH3%[m]
7

20
240
P [hp]
200
P [kW]
531

100

520

100

504
485

40
8000

10000

12000

14000

16000

Q[US.gpm] 18000

40
20000

22000
K42985

Free passage

2 7/8" (72.0 mm)

Rated power P2 and mass moment of inertia J31)


Size

Rated power P2

800-535 / 85 8 UTG
800-535 / 120 8 UTG
800-535 / 160 8 UTG

30)
31)

[hp]
115
160
215

[kW]
85
120
160

Mass moment of inertia J


[kgm2]
3.3
3.3
3.9

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density = 1kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

17

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 850-550
880 rpm32)
1500
90

2000

2500

400

Q [m3/h]

600
70

80

Qmin
75

70

75

70

78

60
70

H [ft]

75

80
80

82

78

80

Q [l/s]

20
84
82

82
80
80

82
80

82

40

1100

84

84
80
82.2

1000

85.5
85.2

82

82

4000

[%]

84

82
84

75

3500

800

78

78

3000

80
78

H [m]

78
75

75

78

70

75

78

70

75

70

543

70

10

557

534
513

20
6000
5000

8000
6000

10000

12000 Q [US.gpm]14000

8000

10000

6
16000

Q [IM.gpm] 12000

18000
14000

543

50
NPSH3% [ft]

NPSH3% [m]

557

15

534
513

10

20
260
180

P [hp]
557

200

P [kW]

543
534

100

513

100
6000

8000

10000

12000 Q [US.gpm] 14000

16000

18000
K42986

Free passage

2 7/8" (72.0 mm)

Rated power P2 and mass moment of inertia J33)


Size

Rated power P2

850-550 / 120 8 UTG


850-550 / 160 8 UTG
850-550 / 205 8 UTG

32)
33)

18

[hp]
160
215
275

[kW]
120
160
205

Mass moment of inertia J


[kgm2]
4.7
5.3
9.9

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density = 1kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 850-550
710 rpm34)
1200

1500

Q [m3/h]

2000

400

2500

600

60

3000

Q [l/s]

800

900

Qmin
70

H [ft]

75

70

75

70

75

40
70

75

78
78

78
78

80
80

80

82

[%]

84

82

85.1
84.8

84

82

82
82
80

78

80

H [m]

84

84

83.6
80
81.8

82
80

80

75
75

70

70

513

5
5000

10

78

78

78

75

20

40

3200

75
70

534

70

557

543

2
6000

8000

4500

10000 Q [US.gpm]

6000

8000

Q [IM.gpm]

12000

14000

10000

12000
557

543

NPSH3% [ft]

NPSH3% [m]
10

534
513

20

10
140

100

P [hp]
557

100

P [kW]

543

534

60
5000

50

513

6000

10000 Q [US.gpm]

8000

12000

14000
K42987

Free passage

2 /8" (72.0 mm)


7

Rated power P2 and mass moment of inertia J35)


Size

Rated power P2

850-550 / 60 10 UTG
850-550 / 90 10 UTG
850-550 / 120 10 UTG

34)
35)

[hp]
75
120
160

[kW]
60
90
120

Mass moment of inertia J


[kgm2]
4.5
4.9
5.2

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density = 1kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

19

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 900-600
880 rpm36)
2000

3000
600

800

100
70

70

75
75

70

75

75

4000

1000

5000

Q [l/s]

1200

1400

Qmin

70

H [ft]

Q [m3/h]

80
80

80

50

[%]

84
84

84
82

84.1

82.4

H [m]

85.4

85

82

80

82

82

84

84

84

82

82
80

82

20

80

80

82

75

80

75

75

70

75

70

70

70

583

605

561
536

5
10
8000
70
NPSH3% [ft]

7000

10000
8000

12000

14000

10000

12000

16000 Q [US.gpm] 18000


Q [US.gpm]

14000

20000
16000

22000
18000
605

583

50

561

20
NPSH3% [m]

536

10
20
380
P [hp]
605

300
583

P [kW]

200

561

200
160
8000

536

120
10000

12000

14000

16000 Q [US.gpm]18000

20000

22000
K42988

Free passage

2 7/8" (72.0 mm)

Rated power P2 and mass moment of inertia J37)


Size

Rated power P2

900-600 / 205 8 UTG


900-600 / 250 8 UTG
900-600 / 290 8 UTG

36)
37)

20

[hp]
275
335
390

[kW]
205
250
290

Mass moment of inertia J


[kgm2]
10.8
12.1
13.4

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density = 1kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 900-615
880 rpm38)
2000

3000
600

100

800
70

75

70

H [ft]
70

50

4000

70

Q [l/s]

80
80

75

80

82

82

1400

84.8

H [m]
20

84
82

84

82.8

1600

85.8

84

84
82

5800

[%]

84

82

80

5000

1200

Qmin

75

75

1000

Q [ m3/h]

82
82

75
75

80

82
80

80

80

70
70

75
75

70

615
588

70

567
545

0
8000
80

10000

7000

12000

14000

16000

10000

Q [US.gpm] 20000
15000

22000

Q [IM.gpm]

0
26000

24000
20000

615

NPSH3% [ft]

588

50

567

20
NPSH3% [m]

545

10
400
615

P [hp]

P [kW]
200

588

200
567
545

50
8000

50
10000

12000

14000

16000

Q [US.gpm] 20000

22000

24000

26000
K42989

Free passage

2 5/8" (67.0 mm)

Rated power P2 and mass moment of inertia J39)


Size

Rated power P2

900-615 / 205 8 UTG


900-615 / 250 8 UTG
900-615 / 290 8 UTG

38)
39)

[hp]
275
335
390

[kW]
205
250
290

Mass moment of inertia J


[kgm2]
11.1
12.4
13.7

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density = 1kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

21

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 900-620
880 rpm40)
1000
140

1500

300

2000

Q [m3/h]

400

2500

600

Q [l/s]

70
70

100
70

75
75

70

75
75

78

78

78
78

3400

800

900
40

Qmin

H [ft]

3000

80

80

80

80

82

82

[%]

83.5

85

85.3

83.5

H [m]

85
83.5

84.2

82

83.5

82

83.9

82.8

83.5

82
80

82

83.5

80

82

82

80
80

75

610

75

78
75

78
75

50

78

78

70

20

585

562

70

540

30
4000
40

6000
4000

8000

10000 Q [US.gpm] 12000

6000

8000

14000

Q [IM.gpm] 10000

NPSH3% [ft]

15000

12000

540

562

585

NPSH3% [m]
10

610

20
4

10
340
P [hp]
300

610

P [kW]
200

585
562

200
540

120
4000

100
6000

8000

10000 Q [US.gpm] 12000

14000

15000

K42993

Free passage

2 1/4" (58.0 mm)

Rated power P2 and mass moment of inertia J41)


Size

Rated power P2

900-620 / 205 8 UTG


900-620 / 250 8 UTG

40)
41)

22

[hp]
275
335

[kW]
205
250

Mass moment of inertia J


[kgm2]
14.1
15.4

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density = 1kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 1000-655
710 rpm42)
2400
80

3000

4000

700

5000

Q [m3/h] 6000

1000

7000

1500

Q [l/s]

7600

2000

Qmin
70
70

60
70

75

H [ft]
70

75

75
75
78

78 80

78
80

78
80
82

80
82

82

[%]

84

84

85.1

86

84

86.2

86

82

86.5

84

40

20

84

84
82

82

84

86

85.1

H [m]

84

86

80

78

20

82
82

80

78

80

80

78

75

10

704

75

689

70

75

78

675

70

656

0
10000
70

15000
10000

20000
15000

25000
20000

NPSH3% [ft]
50

0
34000

Q [US.gpm] 30000
Q [IM.gpm]

25000
689

656

28000
20

704

675

NPSH3% [m]

10
P [hp]
400

P [kW]

704

200

689
675

200

100

656

100
10000

15000

20000

25000

Q [US.gpm] 30000

34000
K42991

Free passage

4" (103.0 mm)

Rated power P2 and mass moment of inertia J43)


Size

Rated power P2

1000-655 / 200 10 UTG


1000-655 / 250 10 UTG
1000-655 / 310 10 UTG

42)
43)

[hp]
270
335
415

[kW]
200
250
310

Mass moment of inertia J


[kgm2]
15.7
17.8
23.8

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density = 1kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

23

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Amacan S 1300-820
590 rpm44)
5000
1300

6000

8000

1500

2000

60
70

75

40
H [ft]

70

78

75

70

75

10000

2500

Q [l/s]

12000
3000

3400

Qmin

75

70

Q [m3/h]

78
78

80
80

82

84

[%]

86

82

80

86

85

82

80

80.4

82
80

80
78

20

84

84

83.1
82

78

H [m]

86.9

84

78

82
80

78

75

80

75

75

70

75

10
78

70

70

818

70

794
776
755

0
20000
17000
40

25000
20000

30000

35000

25000

40000 Q [US.gpm] 45000

30000 Q [IM.gpm] 35000

0
54000

50000
40000
776

44000

794 818

NPSH3% [m]

755

10

NPSH3% [ft]

20
550

400

P [hp]
P [kW]

400
818
794

200
100
20000

200

776
755

25000

30000

35000

40000 Q [US.gpm] 45000

50000

54000
K42992

Free passage

4 1/2" (116.0 mm)

Rated power P2 and mass moment of inertia J45)


Size

Rated power P2

1300-820 / 190 12 UTG


1300-820 / 250 12 UTG
1300-820 / 320 12 UTG
1300-820 / 370 12 UTG

44)
45)

24

[hp]
250
335
430
500

[kW]
190
250
320
370

Mass moment of inertia J


[kgm2]
24.7
30.6
33.3
36.0

Characteristic curves to ISO 9906/2 or Hydraulic Institute, Level B. The characteristic curves correspond to the effective
motor speed.
These values are valid for a density = 1kg/dm and a kinematic viscosity of up to 20 mm/s.

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Dimensions
Outline drawing in unit [inch] UAG motors (650-364 to
800-505)

d5

l2

h1

d4
h4

h2

d1

D
s1

h3

d2

h7

l1

45

d7

d3

d81)

d9

Outline drawing
A
1)

Suction umbrella; option for reducing the minimum water level


d8 varies depending on the type of installation (see General Arrangement Drawings)

Dimensions of the pump set in inch


Size

Motor
size

Number
of poles

h1

h2

h3

h4

l1

l2

650 - 364

26

82 1/4

80 3/4

10 1/4

63

25 5/8

[inch]
2 3/4

24 5/8

19 11/16 20 1/16

15 3/8

1 3/8

Weight46)
[lbs]
2050

650 - 364

30

82 /4

80 /4

10 /4

63

25 /8

2 /4

24 /8

19 /16 20 /16

15 /8

1 3/8

2072

650 - 364

50

82 /4

80 /4

10 /4

63

25 /8

2 /4

24 /8

19 /16 20 /16

15 /8

1 3/8

2094

650 - 365

30

82 1/4

80 3/4

10 1/4

63

25 5/8

2 3/4

24 5/8

19 11/16 20 1/16

15 3/8

1 3/8

2039

650 - 365

50

82 1/4

80 3/4

10 1/4

63

25 5/8

2 3/4

24 5/8

19 11/16 20 1/16

15 3/8

1 3/8

2072

650 - 365

65

82 1/4

80 3/4

10 1/4

63

25 5/8

2 3/4

24 5/8

19 11/16 20 1/16

15 3/8

1 3/8

2138

650 - 404

30

82 7/8

81

11 3/8

63

26 1/8

2 3/4

24 7/16

21 1/4

19 11/16

15 3/8

1 3/8

2094

650 - 404

50

82 7/8

81

11 3/8

63

26 1/8

2 3/4

24 7/16

21 1/4

19 11/16

15 3/8

1 3/8

2116

650 - 404

65

82 7/8

81

11 3/8

63

26 1/8

2 3/4

24 7/16

21 1/4

19 11/16

15 3/8

1 3/8

2183

650 - 405

50

82 7/8

81

11 3/8

63

26 1/8

2 3/4

24 7/16

21 1/4

19 11/16

15 3/8

1 3/8

2072

650 - 405

65

82 7/8

81

11 3/8

63

26 1/8

2 3/4

24 7/16

21 1/4

19 11/16

15 3/8

1 3/8

2138

650 - 405

80

90

88 7/8

11 3/8

71 5/8

26 1/8

2 3/4

24 7/16

21 1/4

19 11/16

15 3/8

1 3/8

2425

650 - 405

100

90

88 7/8

11 3/8

71 5/8

26 1/8

2 3/4

24 7/16

21 1/4

19 11/16

15 3/8

1 3/8

2535

650 - 405

120

90

88 7/8

11 3/8

71 5/8

26 1/8

2 3/4

24 7/16

21 1/4

19 11/16

15 3/8

1 3/8

2673

800 - 505

75

94

92 2/8

14 5/8

75 3/8

31

30

26 3/16

25 1/4

18

3395

800 - 505

100

99

97

14 5/8

80 1/8

31

30

26 3/16

25 1/4

18

3660

800 - 505

120

99

97

14 5/8

80 1/8

31

30

26 3/16

25 1/4

18

3770

46)

Pump set
d1

d2

11

11

d3

d4

d5

Pump set complete with 32.8 ft [10 m] cable (460 V) and 16.4 ft [5 m] rope

Amacan S

25

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Dimensions of the discharge tube in inch


Size

Motor
size

Number of
poles

Discharge tube
d7

h7

d9

s1

[inch]
650 - 364

26

26

20 7/8

8 7/8

35 7/16

650 - 364

30

26

20 /8

8 /8

35 /16

650 - 364

50

26

20 7/8

8 7/8

35 7/16

650 - 365

30

26

20 7/8

8 7/8

35 7/16

650 - 365

50

26

20 7/8

8 7/8

35 7/16

650 - 365

65

26

20 7/8

8 7/8

35 7/16

650 - 404

30

26

20 7/8

10 7/16

35 7/16

650 - 404

50

26

20 7/8

10 7/16

35 7/16

650 - 404

65

26

20 7/8

10 7/16

35 7/16

650 - 405

50

26

20 7/8

10 7/16

35 7/16

650 - 405

65

26

20 /8

10 /16

35 /16

650 - 405

80

26

20 7/8

10 7/16

35 7/16

/16
/16
/16
/16
/16
/16
/16
/16

/16
/16
/16

/16

650 - 405

100

26

20 7/8

10 7/16

35 7/16

650 - 405

120

26

20 7/8

10 7/16

35 7/16

800 - 505

75

32

26

13 3/16

41 3/8

800 - 505

100

32

26

13 3/16

41 3/8

800 - 505

120

32

26

13 3/16

41 3/8

26

Amacan S

/16
/16

/16
/16
/16

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Outline drawing in unit [inch] UTG motors (800-535 to 1300-820)

d5

l2

h1

d4
D

h2

d1
h4

s1

45

45

l1

h7

X
d7

h3

d2

d8 1)

d9

d3

Outline drawing
A
1)

Suction umbrella; option for reducing the minimum water level


d8 varies depending on the type of installation (see General Arrangement Drawings)

Dimensions of the pump set in inch


Size

Motor
size

Number of
poles

h1

h2

h3

h4

d1

d2

Pump set
d3

d4

d5

l1

l2

Weight47)
[lbs]
3726

800 - 535

85

107 7/8

106 5/16

13 3/4

80 11/16

30 1/2

[inch]
26 3/8

27 9/16

18 11/16

1 9/16

34 13/16

3 1/8

800 - 535

120

107 7/8

106 5/16

13 3/4

80 11/16

30 1/2

26 3/8

27 9/16

18 11/16

1 9/16

34 13/16

3 1/8

3748

800 - 535

160

107 7/8

106 5/16

13 3/4

80 11/16

30 1/2

26 3/8

27 9/16

18 11/16

1 9/16

34 13/16

3 1/8

4056

850 - 550

120

109 7/16

107 7/8

16 5/16

82 5/16

32 1/2

28 3/8

27 9/16

18 11/16

1 9/16

34 1/16

3 1/8

3825

850 - 550

160

109 7/16

107 7/8

16 5/16

82 5/16

32 1/2

28 3/8

27 9/16

18 11/16

1 9/16

34 1/16

3 1/8

4145

850 - 550

205

125 9/16

123 1/4

16 5/16

101 15/16

32 1/2

28 3/8

27 9/16

21 7/8

1 15/16

34 1/16

3 9/16

5456

850 - 550

60

10

109 7/16

107 7/8

16 5/16

82 5/16

32 1/2

28 3/8

27 9/16

18 11/16

1 9/16

34 1/16

3 1/8

3682

850 - 550

90

10

109 7/16

107 7/8

16 5/16

82 5/16

32 1/2

28 3/8

27 9/16

18 11/16

1 9/16

34 1/16

3 1/8

3902

850 - 550

120

10

109 7/16

107 7/8

16 5/16

82 5/16

32 1/2

28 3/8

27 9/16

18 11/16

1 9/16

34 1/16

3 1/8

4045

900 - 600

205

123 13/16 121 7/16

17 11/16

100 3/16

34 7/16

30 11/16

29 1/2

21 7/8

1 15/16

35 1/4

3 9/16

5677

900 - 600

250

123 /16 121 /16

17 /16

100 /16

34 /16

30 /16

29 /2

21 /8

1 /16

35 /4

3 9/16

6030

13

11

11

15

900 - 600

290

123 13/16 121 7/16

17 11/16

100 3/16

34 7/16

30 11/16

29 1/2

21 7/8

1 15/16

35 1/4

3 9/16

6349

900 - 615

205

122 13/16

120 1/2

11

17 /16

99 3/16

34 1/4

29 15/16

28 3/4

21 7/8

1 15/16

32 1/16

3 9/16

6129

900 - 615

250

122 13/16

120 1/2

11

17 /16

99 3/16

34 1/4

29 15/16

28 3/4

21 7/8

1 15/16

32 1/16

3 9/16

6504

900 - 615

290

122 /16

120 /2

11

17 /16

99 /16

34 /4

29 /16

28 /4

21 /8

1 /16

32 /16

3 9/16

6812

13

15

15

900 - 620

205

122 1/4

119 7/8

15 15/16

98 5/8

34 7/16

29 3/4

25 3/8

21 7/8

1 15/16

38 3/16

3 9/16

5831

900 - 620

250

122 1/4

119 7/8

15 15/16

98 5/8

34 7/16

29 3/4

25 3/8

21 7/8

1 15/16

38 3/16

3 9/16

6217

1000 - 655

200

10

127 3/8

125

21 5/8

103 3/4

38 3/8

33 11/16

35 7/16

21 7/8

1 15/16

48 1/16

3 9/16

6283

1000 - 655

250

10

127 3/8

125

21 5/8

103 3/4

38 3/8

33 11/16

35 7/16

21 7/8

1 15/16

48 1/16

3 9/16

6757

1000 - 655

310

10

145 1/16

142 1/8

21 5/8

117 1/2

38 3/8

33 11/16

35 7/16

25 9/16

2 3/8

48 1/16

3 9/16

8289

1300 - 820

190

12

129 1/8

126 3/4

23 5/8

105 1/2

47 1/4

38 3/16

41 5/16

21 7/8

1 15/16

47 1/16

3 9/16

8686

47)

Pump set complete with 32.8 ft [10 m] cable (460 V) and 16.4 ft [5 m] rope

Amacan S

27

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Size

Motor
size

Number of
poles

h1

h2

h3

h4

d1

d2

Pump set
d3

d4

d5

l1

l2

Weight47)
[lbs]
10119

1300 - 820

250

12

140 15/16

138

23 5/8

113 3/8

47 1/4

[inch]
38 3/16

41 5/16

25 9/16

2 3/8

47 1/16

3 9/16

1300 - 820

320

12

149 13/16

146 7/8

23 5/8

122 1/4

47 1/4

38 3/16

41 5/16

25 9/16

2 3/8

47 1/16

3 9/16

11001

1300 - 820

370

12

149 13/16

146 7/8

23 5/8

122 1/4

47 1/4

38 3/16

41 5/16

25 9/16

2 3/8

47 1/16

3 9/16

11332

Dimensions of the discharge tube in inch


Size

Motor size

Number of
poles

d7

Discharge tube
d9

h7

800 - 535

85

32

28 3/8

[inch]
51 3/16

800 - 535

120

32

28 /8

51 /16

13

800 - 535

160

32

28 3/8

51 3/16

13

850 - 550

120

34 /16

29 /8

850 - 550

160

34 3/16

850 - 550

205

850 - 550

60

850 - 550

s1

12 /16

12 /16

12 /16

51 /16

15 /16

29 1/8

51 3/16

15 3/16

34 3/16

29 1/8

51 3/16

15 3/16

10

34 3/16

29 1/8

51 3/16

15 3/16

90

10

34 3/16

29 1/8

51 3/16

15 3/16

850 - 550

120

10

34 3/16

29 1/8

51 3/16

15 3/16

900 - 600

205

36

31 1/2

51 3/16

16 3/4

900 - 600

250

36

31 1/2

51 3/16

16 3/4

900 - 600

290

36

31 1/2

51 3/16

16 3/4

900 - 615

205

36

30 11/16

51 3/16

16 15/16

900 - 615

250

36

30 11/16

51 3/16

16 15/16

900 - 615

290

36

30 11/16

51 3/16

16 15/16

900 - 620

205

36

30 5/16

51 3/16

14 3/4

900 - 620

250

36

30 5/16

51 3/16

14 3/4

1000 - 655

200

10

40

36 1/4

59 1/16

20 11/16

1000 - 655

250

10

40

36 1/4

59 1/16

20 11/16

1000 - 655

310

10

40

36 1/4

59 1/16

20 11/16

/8

1300 - 820

250

10

51 15/16

42 1/2

70 7/8

21 7/8

/2

1300 - 820

310

10

51 15/16

42 1/2

70 7/8

21 7/8

/2

1300 - 820

365

10

51 15/16

42 1/2

70 7/8

21 7/8

/2

1300 - 820

420

10

51 15/16

42 1/2

70 7/8

21 7/8

/2

47)

28

Pump set complete with 32.8 ft [10 m] cable (460 V) and 16.4 ft [5 m] rope

Amacan S

13

/16

/16

/16
/16
/16
/16
/16
/16
/16
/8
/8
/8
/8
/8
/8

/8
/8
/8
/8

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Outline drawing in unit [mm] UAG motors (650-364 to 800-505)

d5

l2

h1

d4

h4

h2

d1

D
s1

h3

d2

h7

l1

45

d7

d3

d81)

d9

Outline drawing
A
1)

Suction umbrella; option for reducing the minimum water level


d8 varies depending on the type of installation (see General Arrangement Drawings)

Dimensions of the pump set in mm


Size

650 - 364
650 - 364
650 - 364
650 - 365
650 - 365
650 - 365
650 - 404
650 - 404
650 - 404
650 - 405
650 - 405
650 - 405
650 - 405
650 - 405
800 - 505
800 - 505
800 - 505

48)

Motor
size

Number
of poles

h1

h2

h3

h4

l1

l2

Pump set
d1

26
30
50
30
50
65
30
50
65
50
65
80
100
120
75
100
120

6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8

2090
2090
2090
2090
2090
2090
2105
2105
2105
2105
2105
2305
2305
2305
2400
2520
2520

2042
2042
2042
2042
2042
2058
2058
2058
2058
2058
2258
2258
2258
2343
2463
2463
2463

260
260
260
260
260
260
290
290
290
290
290
290
290
290
370
370
370

1605
1605
1605
1605
1605
1605
1620
1620
1620
1620
1620
1820
1820
1820
1915
2035
2035

651
651
651
651
651
651
665
665
665
665
665
665
665
665
795
795
795

[mm]
70
70
70
70
70
70
70
70
70
70
70
70
70
70
90
90
90

625
625
625
625
625
625
620
620
620
620
620
620
620
620
775
775
775

d2

d3

d4

d5

500
500
500
500
500
500

665
665
665

510
510
510
510
510
510
500
500
500
500
500
500
500
500
645
645
645

390
390
390
390
390
390
390
390
390
390
390
390
390
390
480
480
480

35
35
35
35
35
35
35
35
35
35
35
35
35
35
45
45
45

Weight48)
[kg]
940
940
950
930
940
970
950
960
990
940
970
1100
1150
1190
1540
1660
1710

Pump set complete with 32.8 ft [10 m] cable (460 V) and 16.4 ft [5 m] rope

Amacan S

29

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Dimensions of the discharge tube in mm


Size

650 - 364
650 - 364
650 - 364
650 - 365
650 - 365
650 - 365
650 - 404
650 - 404
650 - 404
650 - 405
650 - 405
650 - 405
650 - 405
650 - 405
800 - 505
800 - 505
800 - 505

30

Motor size

26
30
50
30
50
65
30
50
65
50
65
80
100
120
75
100
120

Amacan S

Number of
poles
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8

D
660
660
660
660
660
660
660
660
660
660
660
660
660
660
813
813
813

d7

Discharge tube
h7

d9

s1

530
530
530
530
530
530
530
530
530
530
530
530
530
530
680
680
680

[mm]
225
225
225
225
225
225
265
265
265
265
265
265
265
265
335
335
335

900
900
900
900
900
900
900
900
900
900
900
900
900
900
1050
1050
1050

7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
8
8
8

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Outline drawing in unit [mm] UTG motors (800-535 to 1300-820)

d5

l2

h1

d4
D

h2

d1
h4

s1

45

45

l1

h7

X
d7

h3

d2

d8 1)

d9

d3

Outline drawing
A
1)

Suction umbrella; option for reducing the minimum water level


d8 varies depending on the type of installation (see General Arrangement Drawings)

Dimensions of the pump set in mm


Size

Motor
size

800 - 535
800 - 535
800 - 535
850 - 550
850 - 550
850 - 550
850 - 550
850 - 550
850 - 550
900 - 600
900 - 600
900 - 600
900 - 615
900 - 615
900 - 615
900 - 620
900 - 620
1000 - 655
1000 - 655
1000 - 655

49)

85
120
160
120
160
205
60
90
120
205
250
290
205
250
290
205
250
200
250
310

Number
of poles
8
8
8
8
8
8
10
10
10
8
8
8
8
8
8
8
8
10
10
10

h1
2740
2740
2740
2780
2780
3190
2780
2780
2780
3145
3145
3145
3120
3120
3120
3105
3105
3235
3235
3685

h2
2700
2700
2700
2740
2740
3130
2740
2740
2740
3085
3085
3085
3060
3060
3060
3045
3045
3175
3175
3610

h3
350
350
350
415
415
415
415
415
415
450
450
450
450
450
450
405
405
550
550
550

h4
2050
2050
2050
2090
2090
2590
2090
2090
2090
2545
2545
2545
2520
2520
2520
2505
2505
2635
2635
2985

Pump set
d3

d1

d2

775
775
775
826
826
826
826
826
826
875
875
875
870
870
870
875
875
975
975
975

[mm]
670
670
670
720
720
720
720
720
720
780
780
780
760
760
760
755
755
855
855
855

700
700
700
700
700
700
700
700
700
750
750
750
730
730
730
645
645
900
900
900

d4

d5

l1

l2

475
475
475
475
475
555
475
475
475
555
555
555
555
555
555
555
555
555
555
650

40
40
40
40
40
50
40
40
40
50
50
50
50
50
50
50
50
50
50
60

885
885
885
865
865
865
865
865
865
895
895
895
815
815
815
970
970
1220
1220
1220

80
80
80
80
80
90
80
80
80
90
90
90
90
90
90
90
90
90
90
90

Weight49)
[kg]
1690
1700
1840
1735
1880
2475
1670
1770
1835
2575
2735
2880
2780
2950
3090
2645
2820
2850
3065
3760

Pump set complete with 32.8 ft [10 m] cable (460 V) and 16.4 ft [5 m] rope

Amacan S

31

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Size

1300 - 820
1300 - 820
1300 - 820
1300 - 820

Motor
size

Number
of poles

h1

h2

h3

h4

d1

d2

Pump set
d3

190
250
320
370

12
12
12
12

3280
3580
3805
3805

3220
3505
3730
3730

600
600
600
600

2680
2880
3105
3105

1200
1200
1200
1200

[mm]
970
970
970
970

1050
1050
1050
1050

d4

d5

l1

l2

555
650
650
650

50
60
60
60

1195
1195
1195
1195

90
90
90
90

Weight49)
[kg]
3940
4590
4990
5140

Dimensions of the discharge tube in mm


Size

Motor size

800 - 535
800 - 535
800 - 535
850 - 550
850 - 550
850 - 550
850 - 550
850 - 550
850 - 550
900 - 600
900 - 600
900 - 600
900 - 615
900 - 615
900 - 615
900 - 620
900 - 620
1000 - 655
1000 - 655
1000 - 655
1300 - 820
1300 - 820
1300 - 820
1300 - 820

49)

32

85
120
160
120
160
205
60
90
120
205
250
290
205
250
290
205
250
200
250
310
190
250
320
370

Number of
poles
8
8
8
8
8
8
10
10
10
8
8
8
8
8
8
8
8
10
10
10
12
12
12
12

D
813
813
813
868
868
868
868
868
868
914
914
914
914
914
914
914
914
1016
1016
1016
1320
1320
1320
1320

d7

Discharge tube
d9

h7

s1

720
720
720
740
740
740
740
740
740
800
800
800
780
780
780
770
770
920
920
920
1080
1080
1080
1080

[mm]
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1500
1500
1500
1800
1800
1800
1800

325
325
325
375
375
375
375
375
375
415
415
415
420
420
420
365
365
515
515
515
545
545
545
545

8
8
8
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
10
10
12
12
12
12

Pump set complete with 32.8 ft [10 m] cable (460 V) and 16.4 ft [5 m] rope

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Installation types
Six design variants are available for different installation types:50)

Installation types

BU discharge tube
Above floor design for installation in open intake chamber

BG discharge tube
Overflow design for installation in covered intake chamber for low suction-side water
levels

CU discharge tube
Design with underfloor discharge line for installation in open intake chamber

CG discharge tube
Design with underfloor discharge line for installation in covered intake chamber for
low suction-side water levels

DU discharge tube
Design with above floor discharge nozzle for installation in open intake chamber

DG discharge tube
Design with above floor discharge nozzle for installation in covered intake chamber
for low suction-side water levels

50)

Refer to the General Arrangement Drawings for information on the various types (foundation dimensions, intake
chamber, etc).

Amacan S

33

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Flow-straightening vane (optional accessory)


Flow-straightening vane and intake chamber
The anti-swirl baffles in the bellmouth (part No. 138) must
be aligned with the flow-straightening vane.

submerged vortex (floor vortex) which could cause a drop in


performance, for example. In addition, the floor and wall
surfaces of the intake chamber should be designed as a rough
concrete surface. Rough surfaces minimize the separation of
boundary layers that may cause wall and floor vortices.

The bail of the pump is oriented in the same direction as


the anti-swirl baffles in the bellmouth.

Design of the intake chamber wall surfaces (to prevent


vortex formation)
The flow-straightening vane is indispensable for the inlet
conditions of the pump set. It prevents the development of a

Variant 1 (concrete variant)


Flow-straightening vane cast from concrete

Variant 2
Steel section

s2

sR

hR

hR

s1

A
B

C
D
lR

(e1)

lR

(e1)

A
Bolted to the floor of the intake chamber
C
Discharge tube
B
Flow-straightening vane centered beneath the discharge tube
D
Intake chamber
The dimensions of the flow-straightening vane depend on the type of installation (see General Arrangement Drawings)

34

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Pump with support rope and turnbuckle in the discharge tube


For large installation depths
(with support)

59-8
59-17.2

59-24
720
59-47*

A
59-17.1

A
59-7

*= The number of (optional) lifting rings depends on the lifting height of the hoisting tackle used and on the building structure.

List of components
Part No.
59-8
59-17.2
59-47
59-24
720
59-17.1
59-7

Description
Turnbuckle
Shackle
Lifting ring
Rope to DIN 3088, type PK, low rotation design
Spacer
Shackle
Support spacer

Material
Stainless steel
Stainless steel
Stainless steel
Stainless steel
EPDM
ST TZN (stainless steel optional)
GFK

Amacan S

35

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Cross-section of cable support


A-A

1
6

3
5

4
OW 380 091-00

List of components
Part No.
1
2
3

Description
Cable clamp (approximately every 400 mm)
Control cable
Power cable

Part No.
4
5
6

Description
Support rope 59-24
Spacer
Clamp cover

Discharge tube cover with cable gland


Design: with welding sleeve
A-A

A
A

List of components
Part No.
1
2
3

36

Description
Discharge tube cover
Cover
Welding sleeve

Amacan S

Water Applications: Water Transport


Submersible Pump in Discharge Tube

Part No.
4
5
6

Description
Threaded bush with cable entry to DIN 22 419 with strain relief and protection against kinking and
twisting
Eyeplate for fastening the cable support (rope)
Gasket, e.g. rubber with fabric reinforcement

Scope of supply
Depending on the model, the following items are included in
the scope of supply:
Basic variant: pump set complete with power cable 32.8 ft
[10 m]
O-ring
Back-up name plate
Accessories (optional):
Support rope
Accessories for installing the cable support
- Spacer
- Turnbuckle
- Support
- Shackle
- Cable clamps
Cable support sleeves
Flow-straightening vane to prevent floor vortices
Discharge tube in various designs (steel or GFK)

Amacan S

37

18.01.2012

KSB PUMPS Inc.


5885 Kennedy Road Mississauga Ontario L 4Z 2G3
Phone: (905) 568-9200 Fax: (905) 568-3740 www.ksb.ca

1589.56/02-US

KSB, Inc.
4415 Sarellen Road Richmond, VA 23231
Phone: (804) 222-1818 Fax: (804) 226-6961 www.ksbusa.com

You might also like