1. Site type and Installation Scenario 2. Hardware instruction 3. Installation instruction 4. Conclusion

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 2

Site type and Installation Scenario


131 sites in total DBS3900 will be used for all of the sites S444 will be used for all of the sites The sites will be installed indoor or out door Indoor sites power supplied by PS48300 Outdoor sites power supplied by APM30 All RRU will be put on the tower

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 3

1. Site type and Installation Scenario 2. Hardware instruction 3. Installation instruction 4. Conclusion

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 4

BBU3900

There are three main function modules which relate to hardware installation in BBU front face:
UELP GTMU UPEU

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 5

UELPE1/T1 lighting protection unit

Dip switch of UELP (Important)

Dip switch SW1

Setting of DIP Bit 1 OFF ON 2 3 4 OFF OFF

Description

OFF OFF OFF ON

120 E1 (Used in this project) 75 E1


Page 6

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

GTMU--The GSM Transmission, Timing, and Management Unit

Dip switch of GTMU (Important)

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 7

UPEU--Universal Power and Environment Interface Unit

The UPEU performs the following functions:


Converting -48 V DC to +12 V DC that is applicable to the boards Providing two RS485 signals and eight dry contact alarms Providing reverse connection protection for power cable connectors

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 8

120 ohm E1 cable

E1 No. 1

Label CHAN 0 TX T1 CHAN 0 RX R1

signal TT0 TR0 RT0 RR0 TT1 TR1 RT1 RR1 TT2 TR2 RT2 RR2 TT3 TR3 RT3 RR3

Color white grey white blue red blue white orange red orange white green red green white brown

Pin 20 19 2 1 22 21 4 3 24 23 6 5 26 25 8 7

Pin assignment of the E1 cable

CHAN 1 TX T2 CHAN 1 RX R2

CHAN 2 TX T3 CHAN 2 RX R3

CHAN 3 TX T4 CHAN 3 RX R4

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 9

RRU3004
RRU module RRU3004 BOX 2 RRU in the rack

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 10

RRU special cables


RRU Interconnect jumper RRU power cable

Signal cable between the CPRI ports on cascaded RRUs

CPRI optical cable

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 11

APM30--Advanced power module 30

Maximum DC power output: APM30 with battery cabinet 48 V/90 A Backup power for a short period: batteries of 48 V (24 Ah) Space for user equipment: 7 U

APM30 inside appearance

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 12

power distribution unit in APM30

To EMUA (5A)

To BBU 3036 (10A) To Tx IDU (10A)

To RRU1 (20A) To RRU2 (20A)


Huawei Confidential

To RRU3 (20A)
Page 13

To DPD32 (50A)

HUAWEI TECHNOLOGIES CO., LTD.

PMU DIP Switch

Default all OFF. Set it to11000000(on--1;off--0)

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 14

PS48300/1800-x6

Maximum DC power output: 48 V/300 A

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 15

1. Site type and Installation Scenario 2. Hardware instruction 3. Installation instruction 4. Conclusion

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 16

Installation instruction Outdoor Scenario Indoor Scenario Swap Scenario

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 17

Outdoor Scenario

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 18

APM30 inside cables connection description


1. 2. Will take on site photo in PNG Battery installation please refer to the related document

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 19

RRU power cables and fibers will be fixed on the cable tray by cable fixing accessory

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 20

RRU Connection of S4 cell

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 21

Real connection example of S4 cell-bottom

Jumper cable need connect to ANT TR/RXA in the right side

PGND to groundi ng bar on the tower

RRU interconnect jumper

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 22

Real connection example of S4 cell-front

RRU inter connect jumper

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 23

Introduce sensor and alarm materials

Alarm cableRJ45 Line

cable:

RJ45 pin RJ45 Pin/ Color 1 2 3 4 5 6 7 8 1 Orange/White 2 Orange 3 Green/white 4 Blue 5 Blue/White 6 Green 7 Brown/White 8 Brown

BBU Recommend pin assignment SW-IN1 SW-IN1 GND SW-IN2 SW-IN3 GND SW-IN3 SW-IN2 GND SW-IN4 SW-IN4 GND

Notes:

Crossover line cable will be used at here. The pin assignment should be same with the upside showing. Alarm panel may use DDF box or something else in the same function.

Pin assignment of EXT_ALM port


HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 24

Alarm Function of UPEU

RJ45 Line cables


Interface Line Cables Color Alarm name Alarm plan boolean 9 boolean 10 boolean 11 boolean 12 boolean 13 boolean 14 boolean 15 boolean 16 Extend alarm Extend alarm Extend alarm Extend alarm Extend alarm Extend alarm Extend alarm Extend alarm
Page 25

EXT-ALM0 Orange/orange white Green/Green white Blue/Blue white Brown/Brown white EXT-ALM1 Orange/orange white Green/Green white Blue/Blue white Brown/Brown white
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Realize Extend alarm by UPEU

Physics connection

RJ45 line cable

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 26

Installation instruction Outdoor Scenario Indoor Scenario Swap Scenario

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 27

Indoor Scenario

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 28

V1.2

Indoor Scenario description

1. 2.

The differences between indoor and outdoor BTS are:


The equipments which under the tower are installed in the BTS room RRU power Cables and fibers will go through switch room window to RRU and antenna Overhead cabling will be used Rectifier is PS48300. BBU and RRU will power supplied by PS48300 BBU and DDF box will be installed in one separate 19 rack Battery will be install in special battery rack and connect to PS48300

3. 4. 5. 6.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 29

Indoor Scenario description

The similarities between indoor and outdoor BTS are:


All of the installation on the tower is same The alarm plan is same Dip switch for BBU and UELP is same requirement

1. 2.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 30

Detail cable connection description in the room

Will on site take photo to describe

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 31

Installation instruction Outdoor Scenario Indoor Scenario Swap Scenario

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 32

Swap Scenario

Swap scenario is basic same with installation new site:


Fellow layout, install all of the under tower equipments whatever indoor or outdoor Install RRU, RRU power cables and fibers Install new antenna system If the plan is use current sites old antenna
Open the connectors between antennas and jumper cables. Use new jumper cables connect the RRU to antenna

1.

2. 3. 4.

The detail plan will be made with customer on site

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 33

Key point for Swap Scenario


1.

Need pay more attention to the alive network. Do not shut down, power off any running equipment without customers permission. Need confirm whether the old antenna will be used after swap Need confirm how about the old feed cables and antenna after swap Need confirm the swap time schedule

2.

3.

4.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 34

1. Site type and Installation Scenario 2. Hardware instruction 3. Installation instruction 4. Conclusion

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 35

Conclusion

Good quality and customers satisfaction is built by us. Please double confirm the fellows items before leave the site: Check the site with hardware quality installation standard GTMU, UELP, PMU dip switch APM30 inside cable connection Alarm cables connection Antenna azimuth, down tilt angle