Detector Cable , FFX200 05SZ1-R/F 1P1.5


FFX200 05SZ1-R 1P1.5 (CU/SR/LSZH 121.5mmsq 300/500V class 2) FFX200 05SZ1-F 1P1.5 (CU/SR/LSZH 121.5mmsq 300/500V class 5)

APPLICATIONS

The cables are single pair stranded flexible cables sheathed with thermoplastic LSZH compound. The cables have the ability to restrict the propagation of the flame in the event of a fire. This is especially important to slow down the spreading of the fire as the cables may pass from one area to another within a building. Applications can be found in control and power circuits, power stations, underground tunnels, lifts, escalators, and high-rise buildings. STANDARDS
Basic design Halogen Free

w w
300/500V

No corrosive gas emission Reduced Fire Propagation Flame Retardance Fire Resistance

Minimum Smoke Emission

o p r i a . w

c rt

c . s e l b a
Plain Annealed Copper LSZH Outer Sheath

Silicone Rubber Insulation

m o

BS 7629-1 IEC 60754-1 IEC 60754-2 IEC 61034/1/2 IEC 60332-3C / NF C 32-070-2.2 (C1)

IEC 60332-1 / NF C 32-070-2.1 (C2) IEC 60331 / BS 5839-1 Clause 26 2d / NF C 32070-2.3(CR1)

VOLTAGE RATING

CABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5. Insulation: Fire resistant silicone rubber compound type EI2 as per BS 7655-1.1

ADDISON

ADDISON
Twisting: Cores are twisted into pairs with varying lay length to minimize crosstalk Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1. Electrical PROPERTIES
Dielectric test: Insulation resistance Short circuit temperature 2000 V r.m.s. x 5 (core/core) 300 M x km (at 20C) 350C

Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30C +90C Temperature range during installation (mobile state): -20C +50C Minimum bending radius: 8 Overall Diameter CONSTRUCTION PARAMETERS
FFX200 05SZ1-R 1P1.5 FFX200 05SZ1-F 1P1.5 No.of pair x Nominal Cross Sectional Area mm
2

o p r i a . N w w w
1 1.5 7/0.53 1 1.5 30/0.25
BS 7629-1
Zero

Number & Nominal Diameter of Strands No/mm

Nominal Insulation Thickness mm 0.5 0.5

c rt

Nominal Sheath Thickness mm 0.5 0.5

c . s e l b a
Nominal Overall Diameter mm 7.0 7.0
Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073

m o

Approx. Weight kg/km 60 60

Standard

Halogen Free IEC60754-1

No Corrosive Gas Emission IEC60754-2

Reduced Fire Propagation NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4

Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1

Fire Resistance IEC 60331 /NF C 32070-2.3(CR1)

Caledonian

Caledonian ULV Cables


www.airport-cables.com

-FAS (Fire Alarm System)

FAS (Fire Alarm System)

Caledonian

enquiry@airport-cables.com

Fire Communication Cable, FFX200 05SZ1-R/F 1P1.5


FFX200 05SZ1-R 1P1.5 (CU/SR/LSZH 121.5mmsq 300/500V class 2) FFX200 05SZ1-F 1P1.5 (CU/SR/LSZH 121.5mmsq 300/500V class 5)

APPLICATIONS

The cables are single pair stranded flexible cables sheathed with thermoplastic LSZH compound. The cables have the ability to restrict the propagation of the flame in the event of a fire. This is especially important to slow down the spreading of the fire as the cables may pass from one area to another within a building. Applications can be found in control and power circuits, power stations, underground tunnels, lifts, escalators, and high-rise buildings. STANDARDS
Basic design Halogen Free

w w
300/500V

No corrosive gas emission Reduced Fire Propagation Flame Retardance Fire Resistance

Minimum Smoke Emission

o p r i a . w

c rt

c . s e l b a
Plain Annealed Copper LSZH Outer Sheath

Silicone Rubber Insulation

m o

BS 7629-1 IEC 60754-1 IEC 60754-2 IEC 61034/1/2 IEC 60332-3C / NF C 32-070-2.2 (C1)

IEC 60332-1 / NF C 32-070-2.1 (C2) IEC 60331 / BS 5839-1 Clause 26 2d / NF C 32070-2.3(CR1)

VOLTAGE RATING

CABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5. Insulation: Fire resistant silicone rubber compound type EI2 as per BS 7655-1.1

ADDISON

ADDISON
Twisting: Cores are twisted into pairs with varying lay length to minimize crosstalk Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1. Electrical PROPERTIES
Dielectric test: Insulation resistance Short circuit temperature 2000 V r.m.s. x 5 (core/core) 300 M x km (at 20C) 350C

Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30C +90C Temperature range during installation (mobile state): -20C +50C Minimum bending radius: 8 Overall Diameter CONSTRUCTION PARAMETERS
FFX200 05SZ1-R 1P1.5 FFX200 05SZ1-F 1P1.5 No.of pair x Nominal Cross Sectional Area mm2 1.5 1.5

o p r i Nw.a w w
1 7/0.53 1 30/0.25
BS 7629-1
Zero

Number & Nominal Diameter of Strands No/mm

Nominal Insulation Thickness mm 0.5 0.5

c rt

Nominal Sheath Thickness mm 0.5 0.5

c . s e l b a
Nominal Overall Diameter mm 7.0 7.0
Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073

m o

Approx. Weight kg/km 60 60

Standard

Halogen Free IEC60754-1/ EN50267-2-1

Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074

Reduced Fire Propagation NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4

Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1

Fire Resistance IEC 60331 /NF C 32070-2.3(CR1)

Caledonian

Caledonian ULV Cables


www.airport-cables.com

-FAS (Fire Alarm System)

FAS (Fire Alarm System) Sounder Cable FFX200 05SZ1-R/F 2G1.5


FFX200 05SZ1-R 2G1.5 (CU/SR/LSZH 21.5mmsq 300/500V class 2) FFX200 05SZ1-F 2G1.5 (CU/SR/LSZH 21.5mmsq 300/500V class 5)

Caledonian

enquiry@airport-cables.com

Silicone Rubber Insulation Plain Annealed Copper

APPLICATIONS

The cables are multicore stranded flexible cables sheathed with thermoplastic LSZH compound. The cables have the ability to restrict the propagation of the flame in the event of a fire. This is especially important to slow down the spreading of the fire as the cables may pass from one area to another within a building. Applications can be found in control and power circuits, power stations, underground tunnels, lifts, escalators, and high-rise buildings. STANDARDS
Basic design Halogen Free

No corrosive gas emission

w w
300/500V

Minimum Smoke Emission Reduced Fire Propagation Flame Retardance Fire Resistance

o p r i a . w
BS 7629-1

c rt

c . s e l b a
LSZH Outer Sheath

m o

IEC 60754-1 IEC 60754-2 IEC 60332-3C / NF C 32070-2.2 (C1) IEC 61034/1/2

IEC 60332-1 / NF C 32-070-2.1 (C2) IEC 60331 / BS 5839-1 Clause 26 2d / NF C 32070-2.3(CR1)

VOLTAGE RATING

CABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5. Insulation: Fire resistant silicone rubber compound type EI2 as per BS 7655-1.1 Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.

ADDISON

ADDISON
Electrical PROPERTIES
Dielectric test: Insulation resistance Short circuit temperature 2000 V r.m.s. x 5 (core/core) 300 M x km (at 20C) 350C

Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30C +90C Temperature range during installation (mobile state): -20C +50C Minimum bending radius: 8 Overall Diameter CONSTRUCTION PARAMETERS
FFX200 05SZ1-R 2G1.5 FFX200 05SZ1-F 2G1.5 Nominal Cross No.of core Sectional Area mm2 2 1.5 2 1.5

Number & Nominal Diameter of Strands No/mm 7/0.53 30/0.25

Nominal Insulation Thickness mm 0.5 0.5

o N irp a . w w w
BS 7629-1
Zero

c rt

Nominal Sheath Thickness mm 0.5 0.5

c . s e l b a
Nominal Overall Diameter mm 7.0 7.0 70 70

m o

Approx.Weight kg/km

Standard

Halogen Free IEC60754-1

Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074

Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073

Reduced Fire Propagation NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4

Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1

Fire Resistance IEC 60331 /NF C 32070-2.3(CR1)

Caledonian

Caledonian ULV Cables


www.airport-cables.com

-FAS (Fire Alarm System)

FAS (Fire Alarm System)

Caledonian

enquiry@airport-cables.com

Control Cable FFX200 05SZ1-R/F 2G2.5


FFX200 05SZ1-R 2G2.5 (CU/SR/LSZH 22.5mmsq 300/500V class 2) FFX200 05SZ1-F 2G2.5 (CU/SR/LSZH 22.5mmsq 300/500V class 5)

Plain Annealed Copper Silicone Rubber Insulation

APPLICATIONS

The cables are multicore stranded flexible cables sheathed with thermoplastic LSZH compound. The cables are designed specially for fire alarm systems where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground. STANDARDS
Basic design Halogen Free

w w
300/500V

No corrosive gas emission Reduced Fire Propagation Flame Retardance Fire Resistance

Minimum Smoke Emission

o p r i a . w

BS 7629-1

c rt

c . s e l b a
LSZH Outer Sheath

m o

IEC 60754-1 IEC 60754-2 IEC 60332-3C / NF C 32070-2.2 (C1) IEC 61034-1/2

IEC 60332-1 / NF C 32-070-2.1 (C2) IEC 60331 / BS 5839-1 Clause 26 2d / NF C 32070-2.3(CR1)

VOLTAGE RATING CABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5. Insulation: Fire resistant silicone rubber compound type EI2 as per BS 7655-1.1. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.

ADDISON

ADDISON
Electrical PROPERTIES
Dielectric test: Insulation resistance Short circuit temperature 2000 V r.m.s. x 5 (core/core) 300 M x km (at 20C) 350C

Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30C +90C Temperature range during installation (mobile state): -20C +50C Minimum bending radius: 8 Overall Diameter CONSTRUCTION PARAMETERS
FFX200 05SZ1-R 2G2.5 FFX200 05SZ1-F 2G2.5 Nominal Cross No.of core Sectional Area mm2 2 2 2.5 2.5

o p r N .ai w w w
7/0.67 50/0.25
BS 7629-1
Zero

Number & Nominal Diameter of Strands No/mm

c rt
mm 0.8 0.8

Nominal Insulation Thickness

Nominal Sheath Thickness mm 1.0 1.0

c . s e l b a
Nominal Overall Diameter mm 9.0 9.0
Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073

m o

Approx. Weight kg/km 105 105

Standard

Halogen Free IEC60754-1

Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074

Reduced Fire Propagation NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4

Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1

Fire Resistance IEC 60331 /NF C 32070-2.3(CR1)

10

Caledonian

Caledonian ULV Cables


www.airport-cables.com

-FAS (Fire Alarm System)

FAS (Fire Alarm System)

Caledonian

enquiry@airport-cables.com

RS485 Data Cable RE-02Y(St)H 1P18A


RE-02Y(St)H 1P18A (CU/PE/OSCR/LSZH 1218AWG)

LSZH Outer Sheath Fireproof tape Stranded Tinned Copper PE Insulation

Overall AL/Polyester Tape With Tinned Copper Drain Wire

APPLICATIONS

The cables are designed for RS485 data connections. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation. STANDARDS
Basic design Halogen Free

No corrosive gas emission

w w

Minimum Smoke Emission Reduced Fire Propagation Flame Retardance Fire Resistance

o p r i a . w

EIA/TIA 485

IEC 60754-1

c rt

c . s e l b a

m o

IEC 60754-2 IEC 60332-3C / NF C 32070-2.2 (C1)

IEC 61034-1/2

IEC 60332-1 / NF C 32-070-2.1 (C2) IEC 60331-23 / NF C 32-070-2.3(CR1)

CABLE CONSTRUCTION Conductors: tinned annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5. Insulation: Solid or foam PE compound Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Overall screen: Aluminum/ polyester tape with tinned copper drain wire. Fire Barrier: Fireproof Tape. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.

ADDISON

11

ADDISON
Electrical Properties
Dielectric test Impedance Capacitance 1000 V r.m.s. for 5 (core-core) 1000 V r.m.s. for 5 (core-screen) 120 45 nF/km conductor to conductor 90 nF/km conductor to shield

Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30C +90C Temperature range during installation (mobile state): -20C +50C Minimum bending radius: 8 Overall Diameter CONSTRUCTION PARAMETERS
RE-02Y(ST)H 1P18A No.of pair Wire Gange AWG 18 18 Number & Nominal Diameter of Strands No/mm 7/0.404 16/0.254

o p r i Nw.a w w
1 1
EIA/TIA 485
Zero

Nominal Insulation Thickness mm 1.15

1.15

c rt
Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074

Nominal Sheath Thickness mm 1.2 1.2

c . s e l b a
Nominal Overall Diameter mm 10.5 10.5 kg/km 100 100
Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073

m o

Approx.Weight

Standard

Halogen Free IEC60754-1

Reduced Fire Propagation NF C32-070-2.2(C1) IEC60332-3-24 EN50266-2-4

Flame Retardancy NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1

Fire Resistance IEC 60331 /NF C 32070-2.3(CR1)

12

Caledonian

You might also like