Flow characteristic
Action
Sizes
End tting
Materials
Body
Seat
Stem
Plug
Packing
ANSI class
Leakage
Max inlet
Water
Media temperature
Water
Maximum P*
Water
Rangeability
Valve weights
G7...DS
chilled or hot water,
60% glycol
G765D(S)
85
G780D(S)
154
G7100D(S)
195
G7125D(S)
248
G7150D(S)
GK Series
68
AF(X) Series
3-way Flanged
GM Series
Inches
NVG
Cv
Suitable Actuators
Electronic
Non-Spring
Spring
Fail-Safe
Dimensions
linear
stem up - open AB to B
2 to 6
125 lb. anged
iron
bronze
stainless steel
bronze
NLP (no lip packing)
iron
stainless steel
stainless steel
stainless steel
TFE V-ring
ANSI 125
ANSI Class III
50 psi (340kPa)
50:1
59 lbs
78 lbs
140 lbs
154 lbs
203 lbs
G765D(S)
G780D(S)
G7100D(S)
G7125D(S)
G7150D(S)
Valve Body
G765D(S)
G780D(S)
G7100D(S)
G7125D(S)
G7150D(S)
Piping
The valves should be mounted in a weather-protected area in a location that is within
the ambient limits of the actuator. Allow sufcient room for valve with actuator and for
service. For the NV Series, allow 6 for cover removal and 12 for complete actuator
removal. The G6/G7 preferred mounting position of the valve is with the valve stem
vertical above the valve body, for maximum life. However, the assemblies can be
mounted with valve stem vertical above the valve or up to 45 degrees in relation to
the horizontal pipe. The actuators should never be mounted underneath the valve, as
condensation can build up and result in a failure of the actuators. Do not reverse ow
direction.
L
C
U = A port
L = B port
C = AB port
Flow Pattern is marked on valve.
800-543-9038 USA
16
Stem Up = Open AB to B
Open C to L
866-805-7089 CANADA
Service
G7...D
chilled or hot water,
60% glycol
Type
D169-G73W
Technical Data
Valve
Nominal Size
7.05" [179]
4.35" [110]
D031
Valve Body
G2
G2
G2
G2
G2
G2
Models
NVD24-MFT US
NV24-MFT US
NVG24-MFT US
Overload protection
Control
Control signal Y
Operating range
Input impedance
Feedback output U
Maximum stroke
Force
NVD24-3 US
NV24-3 US
NVG24-MFT US
Position indication
Manual override
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings
Noise level
Quality standard
800-543-9038 USA
Technical Data
Power supply
Nominal voltage range
Power consumption
NVD24-MFT US
NV24-MFT US
NVG24-MFT US
Transformer sizing
Electrical connection
7.05" [179]
4.35" [110]
Valve Body
G2S
G2S
G2S
G2S
G2S
G2S
866-805-7089 CANADA
23
7.05" [179]
4.35" [110]
7.05" [179]
D166
Valve Body
G3(D)
G3(D)
G3(D)
G3(D)
G3(D)
G3(D)
G3(D)
4.35" [110]
7.05" [179]
D166_A
Dimensions with G6/G6C ANSI 125 and G6 ANSI 250 Series 2-Way Valve
Valve Body
G7 ANSI 125
G7 ANSI 125
G7D ANSI 125
G7D ANSI 125
G7D ANSI 125
G7 ANSI 250
G7 ANSI 250
G7D ANSI 250
G7D ANSI 250
G7D ANSI 250
W130
Wiring Diagrams
24 VAC Transformer
2 to 10 VDC ()
Feedback Signal (+)
NVD24-MFT US
NV24-MFT US
NVG24-MFT US
24 VAC Transformer
NV24 MFT US
NVG24-MFT US
24 VAC Transformer
Blk (1) Common
Line
Volts
4 to 20 mA ()
Control Signal (+)
2 to 10 VDC ()
Feedback Signal (+)
500
4 to 20 mA Control Signal
800-543-9038 USA
24
866-805-7089 CANADA
Line
Volts
GM
2 x GM
62
42
113
78
19
150
121
150
150
800-543-9038 USA
88
NVF
150
136
Electronic Fail-Safe
AF
2x AF
AFX
2 x AFX
GK
36
24
59
40
51
34
82
56
113
78
19
150
150
150
150
150
150
212
152
105
250
239
178
150
150
150
150
150
Spring Return
NVG
150
150
132
87
50
250
250
250
239
178
62
42
113
78
19
176
121
36
24
59
40
51
34
82
56
113
78
19
62
42
113
78
19
150
121
31
19
13
36
24
59
40
51
34
82
56
13
114
78
19
62
42
113
78
176
121
31
19
13
35
23
58
40
40
25
114
77
24
114
78
19
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
866-805-7089 CANADA
NV