Overview
In the past, heat-recovery steam generators (HRSGs) primarily served lower pressure industrial applications to recover heat from chemical or manufacturing processes. They operated at around 500 psig and used softened water as boiler-water makeup. Today, HRSGs operate at substantially higher pressures and in a variety of configurations. They use sophisticated water treatment systems and play an integral role in the combinedcycle power plant. No operator would consider running a steam generator over its design pressure without recertifying the unit in accordance with ASME code. But, are there risks associated with operating a HRSG below its design pressure, such as sliding pressure operation?
1/21/02
Page 2 of 3
steam found in the low-pressure (l-p) section. One pound of 50-psig steam occupies 6.6 cubic feet, while the 25-psig steam occupies 10.5 cubic feet. This density change increases the steam volume by a factor of 1.6. 2. The second factor, lower saturation temperature, increases the rate of steam production by a factor of 1.3, or 13,060 lb/hr steam flow at reduced pressure versus 10,000 lb/hr steam flow at 50 psig. Given a constant 400oF exhaust-gas temperature entering the l-p section, the exhaust-gas temperature exiting is 289 oF at reduced pressure as compared to 315 oF for 50 psig steam. Together these two factors increase the steam velocity to more than twice the design value (1.6x1.3=2.08). The risk of flow accelerated corrosion is especially severe for steam generators operating below 250 psig.
Case Study
A heat-recovery steam generator (HRSG) experienced tube leaks in its low-pressure (l-p) section after just three years of operation. Testing revealed severe thinning at the upper bends of the low-pressure tubes. Operating at reduced pressure proved to be the root cause of the flow accelerated corrosion. This HRSG was not designed for reduced-pressure operation. At actual reduced pressure operation, thermal performance of the high-pressure and intermediate-pressure sections was greater than design. This negatively impacted the low-pressure section because the turbine gas temperature was lower than design in the l-p section. At design operating conditions, the low-pressure deaerator requires minimal pegging steam, however at reduced pressure operation, the pegging steam control valve was too small to keep up with the increased demand. This would cause the l-p boiler pressure to decrease, and go as low as 3 psig. Plant operators were not concerned, because the deaerator was still performing satisfactorily. What they did not realize was that the steam velocity in the l-p tubes had increased by a factor of two. Extensive repairs to the l-p section upper bends were required after only three years.
Monitoring Technique
1. Calculate the actual steam velocity in the low-pressure section of the HRSG. 2. Begin calculating velocity when pegging steam control valve is greater than 80% open. 3. Compare actual steam velocity with the steam velocity at design conditions. 4. Send a warning to the operators when actual steam velocity exceeds design by file://C:\Lib\Mechanical\Fixed Equipment\Heat Recovery...\HRSG Steam Velocity Analysis.ht 1/21/02
Page 3 of 3
Literature Review
1. Reduced-pressure operation shortens HRSG service life by Robert Krowech, published in Power Magazine, January/February 2000. 2. HRSGs: A different breed of boiler by David Daniels, published in Power Magazine, November/December 1999. Warning: Cycling HRSGs can be dangerous to your health by Michael Pearson, published in Power Magazine, February 1997. Competitive realities change focus of boiler/HRSG design by Cate Jones, published in Power Magazine, February 1996.
3.
4.
5. Pasco county cogeneration facility, First-of-a-kind aero turbines boost cogen-plant performance, published in Power Magazine, April 1994.
1/21/02