Operating Manual
Reset Module SP-ECH ECH-ROT/MT
for dryers with ith Multitronic controller

Version: 03-DE

Author: M. Schulte

Date: 13.07.2010

SP-ECH-ROT/MT ROT/MT reset module for ZANDER MULTITRONIC controller control


Dear Customer, This operating manual contains information that is valid v for reset-module usage. Proper operation can only be guaranteed if the instructions and notes are observed.

For your safety


All the work on the controller must only be carried out by qualified experts or instructed persons! Risk of injury from electric voltage The controller is connected to voltage, i.e. it is live, and must only be opened and maintained by authorised personnel. ATTENTION: The electric supply line is still live! Do not touch live parts!

2
Intended use of the reset module
The reset module is only used for resetting the service messages of the MULTITRONIC controller shown above. The module or the controller must never be technically modified. Any modifications may affect the operational safety and might lead to damages. FST GmbH accepts no liability resulting from improper handling or technical modifications.

Function description and application


Function
The "SEr." service message is indicated on the display of the MULTITRONIC control system every 8000 *) operating hours. The message is flashing and alternates with the standard indication at intervals of 1 minute.
*) Depending on the system (e.g. systems for breathing air treatment) the service interval setting may be shorter.

Using this reset module and following successful maintenance the service monitor is reset to "0". The "SEr." message then only appears again after another 8000 operating hours. The reset module can only be used once and will then render unusable.

Application
Please proceed exactly as described in the following: 1. Switch off the MULTITRONIC controller via the main circuit breaker on the left. 2. Loosen the 4 Phillips head screws and remove the MULTITRONIC front cover. Note: To facilitate service work the cover can be screwed in the two upper housing holes using the two lower screws. This fixes the cover and therefore the cover does not obstruct the user. 3. Connect the reset module to the serial port. 4. Switch on the MULTITRONIC controller. 5. After a short time the LED on the reset module lights up*. This completes the reset procedure. As soon as the LED on the module starts flashing the code has been read and the module cannot be used again. 6. To protect the controller, switch it off again and remove the reset module. 7. Reinstall the front cover and restart the MULTITRONIC controller. 8. Note: The reset module can reset the service timer at any time, even if the "SEr." message do not (or not yet) appear.
picture: serial port

Storage
Store the reset module in a dry and dust-free environment. It must not be subject to strong magnetic fields, temperatures > 50C or intensive sunlight.

Disposal
Waste code: According to the European Waste Catalogue the reset module belongs to "components removed from discarded equipment", waste code no. 160216.

Filtrations- und Separationstechnik GmbH, Im Teelbruch 106, D - 45219 Essen, Tel.: +49 (0)2054 8735 -0 www.fstweb.de