You are on page 1of 74

SYMON BROS.

CONSTRUCTION PTY LTD

FEATHERBROOK ESTATE
STAGES 7, 8, & 9A

POINT COOK

Report On

LEVEL 1
SURVEILLANCE
& COMPACTION CONTROL OF
ALLOTMENT FILLING

Carried Out
By

JOB No.: 1395/135


Factory 1/8-10 Catalina Dve, Tullamarine, Vic 3043
PO Box 184, Keilor, Vic, 3036
PH (03) 9335-1225 FAX (03) 9335-1775

th
18 March 2009
#1395/135

Symon Bros. Construction Pty Ltd


146 Mahoneys Road
Thomastown 3074
Attention: - Mr. Jason Farrugia

Dear Sir,

RE: Featherbrook Estate Stage 7, 8, 9A - Allotment Filling

Introduction & Scope

At the request of Symon Bros. Construction Pty Ltd, Geotechnical


Laboratories has carried out inspection and testing of the above mentioned
site from the 16th of June 2008 to the 3rd of September 2008 where a
residential development is being constructed. Inspection and testing of
stripping, material quality and compaction control tests were carried out to
comply with the requirements of AS 3798 Appendix B, Level 1.

The following documentation was submitted to Geotechnical Laboratories by


Symon Bros. Construction Pty Ltd and was used to determine compliance of
earthworks in conjunction with the requirements of AS 3798 - 1996 (See
Appendix A).

(1). Standard Faceplan Layout Drawing.

General site works involved the placement of fill, using clays sourced from on-
site, to bring the allotments to the required finish levels as indicated on
faceplan drawings. Photographs taken of the site construction process can be
found in Appendix B of this report.

Level 1 Report Featherbrook Stage 7,8 & 9A 2


Site Preparation
th
Site inspections were undertaken on the 13 of June 2008 confirming that
selected areas to be filled were completely stripped of topsoil prior to filling.
The brown silty topsoils had been stockpiled around the site for later removal
off-site.

The existing dam had been drained and de-sludged. A clean firm base was
presented for inspection and approval given prior to any filling commencing.

Proof roll inspections were performed throughout the project duration to


ensure no significant soft areas were present prior to filling.

Material

It is understood that the fill material used was sourced from on-site
excavations, mainly rod boxing and drainage trench excavations.

The material is described as, CLAY FILLS, brown, grey-brown, red-brown,


high plasticity, dry to slightly moist, with basalt gravel and occasional
cobbles.

The fill material is consistent with the naturally occurring soils for this region.

Source material was deemed a Suitable Material in accordance with the


guidelines set out in AS 3798 - 1996 Section 4.3.

Compaction of Fill Material

A sheeps foot compactor placed material in horizontal loose layers of


approximately 250-300mm. The sheeps foot compactor also performed
compaction of the clay fills operating in a criss-cross pattern. The moisture
condition of the fill was closely monitored and moisture conditioning
procedures were applied to bring the material closer to it's Standard Optimum
Moisture Content (AS 1289 5.7.1).

Moisture conditioning was performed using a water cart and mixing with the
compactor prior to sheeps foot rolling.

Compaction Testing

Compaction control testing was performed on-site using a Nuclear


Densometer in accordance with AS 1289 5.8.1. Laboratory reference densities
were determined from material sampled at each test site location using the Hilf
Rapid Compaction Method in accordance with AS 1289 5.7.1.

Level 1 Report Featherbrook Stage 7,8 & 9A 3


A total of 100 compaction tests were performed on the clay filling. Results are
presented in Appendix A of this report.

Testing frequencies were in accordance with AS 3798 - 1996 Table 5.1 for
Large Scale Operations.

Acceptance of fill layers for compaction was based on the requirements of AS


3798 - 1996 Table 5.1 Item 1. Residential. As a result the compliance criteria
adopted by Geotechnical Laboratories was a hilf density ratio not less than 95
percent of the maximum hilf density value as determined by the Standard Hilf
Rapid Compaction Method in accordance with AS 1289 5.7.1.

A total of one test was deemed to be non-compliant with the above


requirement. Symon Bros. Construction were notified at the time of testing and
remedial works were undertaken until such time that they could be presented
for re-testing and found to be compliant. All other test results indicate that the
compaction requirements were successfully achieved.

No moisture criteria was specified.

Remarks

So far as can be determined, Symon Bros. Construction Pty Ltd have


satisfactorily complied with the compaction and construction processes
required for the structural filling of this site. As such structural filling placed on
th
this site by Symon Bros. Construction Pty Ltd from the 16 of June 2008 to
the 3rd of September 2008 can be categorised as CONTROLLED FILL in
accordance with AS 2870-1996.

Note: Test results and controlled fill certification relates only to fill placed by
Symon Bros. Construction Pty Ltd and for earthworks completed at the time of
testing. Any previous or subsequent earthworks will require a separate
evaluation.

Yours Faithfully
GEOTECHNICAL LABORATORIES

Sam Loza
Laboratory Manager

Level 1 Report Featherbrook Stage 7,8 & 9A 4


SYMON BROS.
CONSTRUCTION PTY LTD

FEATHERBROOK ESTATE
STAGES 7, 8, 9A

PT COOK

Report On

LEVEL 1
SURVEILLANCE
& COMPACTION CONTROL OF
ALLOTMENT FILLING

Carried Out
By

APPENDIX A
Level 1 Report Featherbrook Stage 7,8 & 9A 5
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/123
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

16/06/08 215 1.89 16.5 106.0  1.78  21.5 175 5.0 Drier 77.0 - - 1200

16/06/08 216 1.90 17.5 105.0  1.80  21.5 175 4.0 Drier 80.5 - - 1000

16/06/08 217 Refer to #1394/124 for 1.91 16.0 105.5  1.81  20.5 175 4.0 Drier 79.5 - - 1000
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 ANTHONY BONNICI
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 17/6/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


215

216

217

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 16/6/08 JOB No.: 1394-124


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/136
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

17/06/08 242 1.97 18.0 108.0  1.82  23.0 175 5.0 Drier 77.5 - - 800

17/06/08 243 2.00 18.0 111.0  1.81  23.0 175 5.0 Drier 78.5 - - 600

17/06/08 244 Refer to #1394/137 for 2.01 16.5 110.0  1.83  20.5 175 4.0 Drier 80.0 - - 600
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 19/6/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


243
242

244

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 17/6/08 JOB No.: 1394-137


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/138
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

18/06/08 245 1.85 14.5 102.0  1.81  20.0 175 5.5 Drier 71.5 - - 200

18/06/08 246 2.01 18.0 107.5  1.87  20.0 175 2.5 Drier 88.5 - - 400

18/06/08 247 Refer to #1394/139 for 1.97 17.5 104.5  1.88  22.0 175 4.0 Drier 80.5 - - 600
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 19/6/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


245

246

247

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 18/6/08 JOB No.: 1394-139


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/144
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

19/06/08 257 1.77 17.5 102.0  1.73  22.5 175 4.5 Drier 79.0 - - 400

19/06/08 258 1.86 17.0 98.5 ? 1.89  21.0 175 4.0 Drier 81.0 17 0 0

19/06/08 259 Refer to #1394/145 for 2.09 14.0 101.5 ? 2.06  17.5 175 4.0 Drier 78.0 20 0 0
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 23/6/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


257
258

259

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 19/6/08 JOB No.: 1394-145


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/150
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

24/06/08 267 1.90 16.5 103.0 ? 1.84  21.0 175 4.0 Drier 80.0 7 0 400

24/06/08 268 2.00 14.0 105.0 ? 1.90  18.0 175 4.0 Drier 77.0 4 0 200

24/06/08 269 Refer to #1394/151 for 1.80 16.5 101.5 ? 1.77  21.0 175 4.5 Drier 79.0 7 0 0
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 26/2/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


267

269

268

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 24/6/08 JOB No.: 1394-151


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/152
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

25/06/08 270 1.85 19.0 103.5  1.79  23.5 175 4.5 Drier 81.5 - - 0

25/06/08 271 1.92 17.5 102.0  1.88  19.5 175 2.5 Drier 88.0 - - 0

25/06/08 272 Refer to #1394/153 for 1.77 25.5 92.5  1.92  24.0 175 1.5 Wetter 106.5 - - 0
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 27/6/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


272

271
270

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 25/6/08 JOB No.: 1394-153


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/154
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

26/06/08 273 1.81 17.0 100.5  1.79  22.0 175 4.5 Drier 78.5 - - 0

26/06/08 274 1.79 17.5 100.5  1.78  23.0 175 5.5 Drier 76.5 - - 0

26/06/08 275 Refer to #1394/155 for 1.75 16.0 100.0  1.75  20.5 175 5.0 Drier 76.5 - - 0
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 1/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


275 273

274

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 26/6/08 JOB No.: 1394-155


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/156
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

27/06/08 276 1.80 17.5 95.0 ? 1.89  22.0 175 4.5 Drier 79.5 11 0 2700

27/06/08 277 1.87 16.5 98.5 ? 1.90  20.5 175 4.0 Drier 79.5 12 0 2600

27/06/08 278 Refer to #1394/157 for 1.79 17.0 98.0  1.83  21.5 175 4.0 Drier 80.5 - - 2600
approx test site
27/06/08 279 2.00 18.0 107.5  1.86  22.0 175 4.0 Drier 81.0 - - 0
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1. Test #279 is retest #272 taken 25/6/08
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 1/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


279

278

277

276

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 27/6/08 JOB No.: 1394-157


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/160
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

30/06/08 284 1.86 16.5 100.0 ? 1.86  20.5 175 4.0 Drier 79.5 15 0 2400

30/06/08 285 2.00 17.5 104.5 ? 1.91  21.5 175 4.0 Drier 80.5 8 0 2400

30/06/08 286 Refer to #1394/161 for 1.93 19.5 102.0 ? 1.90  24.0 175 4.5 Drier 81.0 7 0 2400
approx test site
- - - - -  -  - - - - - - -
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Dam Backfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 2/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


284

285

286

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 30/6/08 JOB No.: 1394-161


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/162
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

1/07/08 287 1.98 16.5 105.5 ? 1.87  21.0 175 4.5 Drier 79.0 6 0 2200

1/07/08 288 1.90 18.0 104.5  1.82  22.5 175 4.5 Drier 81.0 - - 2200

1/07/08 289 Refer to #1394/163 for 1.97 21.5 106.0  1.86  26.0 175 4.5 Drier 83.0 - - 2200
approx test site
- - - - -  -  - - - - - - -
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Dam Backfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 2/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


287

288

289

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 01/07/08 JOB No.: 1394-163


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/164
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

2/07/08 290 1.86 16.5 104.0 ? 1.79  21.0 175 4.5 Drier 79.0 1 0 2000

2/07/08 291 1.88 17.0 103.0 ? 1.83  22.0 175 5.0 Drier 78.0 5 0 2000

2/07/08 292 Refer to #1394/165 for 1.86 18.5 101.5 ? 1.83  23.5 175 5.0 Drier 79.0 8 0 2000
approx test site
- - - - -  -  - - - - - - -
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Dam Backfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 8/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


292

291

290

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 02/07/08 JOB No.: 1394-165


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/166
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

3/07/08 293 1.90 20.0 100.0 ? 1.90  23.0 175 3.0 Drier 86.5 8 0 1800

3/07/08 294 1.93 23.0 96.0 ? 2.00  26.5 175 3.0 Drier 88.0 20 0 1800

3/07/08 295 Refer to #1394/167 for 1.92 17.5 101.5 ? 1.90  20.5 175 3.0 Drier 86.0 8 0 1800
approx test site
- - - - -  -  - - - - - - -
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Dam Backfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 9/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


295

294

293

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 03/07/08 JOB No.: 1394-167


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/168
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

4/07/08 296 1.95 16.5 107.5  1.81  22.5 175 5.5 Drier 75.0 - - 1600

4/07/08 297 1.95 20.0 104.5  1.86  24.0 175 4.0 Drier 83.0 - - 700

4/07/08 298 Refer to #1394/169 for 2.08 22.5 105.0 ? 1.99  26.0 175 3.5 Drier 86.5 17 0 400
approx test site
- - - - -  -  - - - - - - -
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Dam Backfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 9/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


298

297

296

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 04/07/08 JOB No.: 1394-169


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/170
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

7/07/08 299 1.86 16.0 100.5 ? 1.85  20.5 175 4.5 Drier 78.5 4 0 1600

7/07/08 300 1.86 16.0 101.0 ? 1.85  20.0 175 4.0 Drier 79.5 3 0 1400

7/07/08 301 Refer to #1394/170 for 1.92 18.5 103.5  1.85  22.5 175 4.0 Drier 82.0 - - 400
approx test site
- - - - -  -  - - - - - - -
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 9/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


301

300

299

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 07/07/08 JOB No.: 1394-171


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: JL CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/174
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM APPROX. DEPTH
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET
TEST WET MOISTURE DEPTH OPTIMUM BELOW FINISHED
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm
NUM. DENSITY CONTENT SETTING MOISTURE LEVEL
TESTS STANDARD APCWD CONTENT (%) (%) (%)
(t/m³) (%) (mm) CONTENT (mm)
(%) (t/m³) (%)
(%)

8/07/08 303 1.88 24.0 96.0 ? 1.96  24.5 175 0.0 Drier 99.0 8 0 1200

8/07/08 304 1.88 15.5 101.5  1.85  20.0 175 4.5 Drier 78.0 - - 1900

8/07/08 305 Refer to #1394/175 for 1.82 16.0 101.0  1.81  20.0 175 4.0 Drier 79.5 - - 1900
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 15/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


304

303

305

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 08/07/08 JOB No.: 1394-175


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/181
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM APPROX. DEPTH
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET
TEST WET MOISTURE DEPTH OPTIMUM BELOW FINISHED
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm
NUM. DENSITY CONTENT SETTING MOISTURE LEVEL
TESTS STANDARD APCWD CONTENT (%) (%) (%)
(t/m³) (%) (mm) CONTENT (mm)
(%) (t/m³) (%)
(%)

9/07/08 315 1.82 17.5 100.0  1.82  22.0 175 4.5 Drier 79.5 - - 1000

9/07/08 316 1.90 17.0 101.5 ? 1.88  21.0 175 4.0 Drier 80.0 7 0 800

9/07/08 317 Refer to #1394/182 for 1.91 24.5 96.0 ? 1.99  28.0 175 3.5 Drier 87.5 18 0 800
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 15/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


315

316

317

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 09/07/08 JOB No.: 1394-182


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/183
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM APPROX DEPTH
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET
TEST WET MOISTURE DEPTH OPTIMUM BELOW FINISHED
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm
NUM. DENSITY CONTENT SETTING MOISTURE LEVEL
TESTS STANDARD APCWD CONTENT (%) (%) (%)
(t/m³) (%) (mm) CONTENT (mm)
(%) (t/m³) (%)
(%)

10/07/08 318 1.99 20.0 104.5  1.90  25.0 175 4.5 Drier 81.5 - - 200

10/07/08 319 1.85 20.0 98.5  1.87  24.0 175 4.5 Drier 82.0 - - 400

10/07/08 320 Refer to #1394/184 for 1.82 18.5 99.0  1.84  23.0 175 4.5 Drier 80.5 - - 600
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 15/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


318 319

320

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 10/07/08 JOB No.: 1394-184


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/187
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM APPROX. DEPTH
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET
TEST WET MOISTURE DEPTH OPTIMUM BELOW FINISHED
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm
NUM. DENSITY CONTENT SETTING MOISTURE LEVEL
TESTS STANDARD APCWD CONTENT (%) (%) (%)
(t/m³) (%) (mm) CONTENT (mm)
(%) (t/m³) (%)
(%)

11/07/08 323 1.84 20.5 95.0 ? 1.93  24.0 175 3.5 Drier 86.0 12 0 200

11/07/08 324 1.93 19.5 105.5  1.83  23.0 175 3.5 Drier 85.5 - - 200

11/07/08 325 Refer to #1394/188 for 2.01 18.0 105.0  1.92  21.0 175 3.5 Drier 84.5 - - 200
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 15/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


323

324

325

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 11/07/08 JOB No.: 1394-188


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/189
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM APPROX. DEPTH
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET
TEST WET MOISTURE DEPTH OPTIMUM BELOW FINISHED
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm
NUM. DENSITY CONTENT SETTING MOISTURE LEVEL
TESTS STANDARD APCWD CONTENT (%) (%) (%)
(t/m³) (%) (mm) CONTENT (mm)
(%) (t/m³) (%)
(%)

15/07/08 326 1.85 17.0 103.5  1.79  20.5 175 3.5 Drier 84.0 - - 0

15/07/08 327 1.86 21.0 99.5 ? 1.87  25.5 175 4.5 Drier 83.0 9 0 0

15/07/08 328 Refer to #1394/190 for 1.84 20.5 100.5  1.83  23.5 175 3.0 Drier 87.0 - - 2200
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 18/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


327

326

328

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 15/07/08 JOB No.: 1394-190


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/191
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM APPROX. DEPTH
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET
TEST WET MOISTURE DEPTH OPTIMUM BELOW FINISHED
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm
NUM. DENSITY CONTENT SETTING MOISTURE LEVEL
TESTS STANDARD APCWD CONTENT (%) (%) (%)
(t/m³) (%) (mm) CONTENT (mm)
(%) (t/m³) (%)
(%)

16/07/08 329 1.82 18.5 100.0 ? 1.82  22.5 175 4.5 Drier 81.0 4 0 800

16/07/08 330 1.88 22.5 101.0  1.86  26.5 175 4.5 Drier 83.5 - - 2000

16/07/08 331 Refer to #1394/192 for 1.83 23.5 97.5 ? 1.88  27.5 175 4.0 Drier 85.0 5 0 0
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 18/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


331

329

330

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 16/07/08 JOB No.: 1394-192


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/195
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

18/07/08 335 1.75 16.0 100.0  1.74  21.0 175 5.0 Drier 75.5 - - 1000

18/07/08 336 1.92 16.5 101.5 ? 1.89  22.0 175 5.5 Drier 75.5 5 0 1000

18/07/08 337 Refer to #1394/196 for 1.81 19.5 102.5  1.76  25.0 175 5.5 Drier 78.0 - - 1000
approx test site
- - - - -  -  - - - - - - -
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 21/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


337

336
335

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 18/07/08 JOB No.: 1394-196


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/197
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

17/07/08 338 1.98 19.5 104.0  1.91  24.5 175 4.5 Drier 81.0 - - 600

17/07/08 339 1.84 14.5 104.0  1.77  18.5 175 4.0 Drier 77.5 - - 1000

17/07/08 340 Refer to #1394/198 for 1.85 20.0 101.0  1.83  24.5 175 4.5 Drier 81.5 - - 800
approx test site
- - - - -  -  - - - - - - -
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 22/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


339
338

340

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 17/07/08 JOB No.: 1394-198


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/199
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

24/07/08 341 1.86 22.5 98.5  1.89  21.5 175 1.0 Wetter 105.5 - - 700

24/07/08 342 1.87 25.0 108.5  1.72  24.5 175 0.5 Wetter 102.0 - - 700

24/07/08 343 Refer to #1394/200 for 1.89 30.5 105.0  1.79  31.0 175 0.5 Drier 98.5 - - 700
approx test site
- - - - -  -  - - - - - - -
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 29/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


341

342

343

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 24/07/08 JOB No.: 1394-200


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/201
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

28/07/08 344 1.98 21.5 105.0  1.89  25.5 175 4.0 Drier 85.0 - - 1800

28/07/08 345 1.84 20.0 102.5  1.79  23.5 175 3.5 Drier 84.5 - - 1800

28/07/08 346 Refer to #1394/202 for 1.98 19.0 103.5  1.91  21.0 175 2.0 Drier 91.0 - - 1800
approx test site
- - - - -  -  - - - - - - -
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 29/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


344

346
345

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 28/07/08 JOB No.: 1394-202


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/203
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

30/07/08 347 1.97 22.5 107.5  1.84  25.5 175 2.5 Drier 89.5 - - 0

30/07/08 348 1.95 21.5 106.5  1.83  24.0 175 2.5 Drier 90.0 - - 0

30/07/08 349 Refer to #1394/204 for 1.93 21.0 108.0  1.78  24.0 175 3.0 Drier 88.0 - - 0
approx test site
- - - - -  -  - - - - - - -
locations
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 31/7/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


347

349

348

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 30/07/08 JOB No.: 1394-204


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/205
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

31/07/08 350 2.04 19.5 105.0  1.94  22.5 175 3.0 Drier 86.5 - - 500

31/07/08 351 1.97 19.0 102.0  1.93  22.5 175 3.0 Drier 86.0 - - 500

31/07/08 352 Refer to #1394/206 for 2.02 22.5 106.5  1.89  25.5 175 3.0 Drier 87.5 - - 500
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 4/8/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


347

349

348

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 31/07/08 JOB No.: 1394-206


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/207
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

1/08/08 353 1.91 22.5 100.5  1.90  25.5 175 3.0 Drier 87.5 - - 300

1/08/08 354 1.85 21.5 99.0  1.86  24.5 175 3.0 Drier 87.0 - - 300

1/08/08 355 Refer to #1394/208 for 1.99 27.5 108.5  1.83  31.0 175 3.5 Drier 89.5 - - 500
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 4/8/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


354

355

353

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 1/8/08 JOB No.: 1394-208


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/209
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

4/08/08 356 1.99 21.5 111.0  1.79  25.5 175 4.0 Drier 84.5 - - 500

4/08/08 357 1.85 22.0 102.5  1.81  26.0 175 4.0 Drier 85.0 - - 500

4/08/08 358 Refer to #1394/210 for 2.10 18.5 108.5 ? 1.93  21.5 175 3.0 Drier 85.5 7 0 300
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 5/8/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


356

357

358

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 4/8/08 JOB No.: 1394-210


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/211
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

7/08/08 359 2.04 20.5 109.5  1.86  23.5 175 3.5 Drier 86.0 - - 200

7/08/08 360 2.06 21.5 106.0 ? 1.94  24.5 175 3.0 Drier 88.0 3 0 200

7/08/08 361 Refer to #1394/212 for 2.03 19.0 104.0 ? 1.95  23.0 175 4.5 Drier 81.5 10 0 200
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayfill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 9/8/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


361

360

359

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 7/8/08 JOB No.: 1394-212


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/226
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

27/08/08 379 1.93 26.0 101.0  1.90  25.5 175 0.5 Wetter 101.0 - - 300

27/08/08 380 1.88 32.0 101.0  1.86  31.5 175 0.5 Wetter 101.0 - - 300

27/08/08 381 Refer to #1394/227 for 1.89 28.0 102.0  1.85  27.5 175 0.5 Wetter 101.0 - - 300
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Allotment Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 29/8/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


379

380

381

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 27/8/08 JOB No.: 1394-226


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/229
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

28/08/08 382 1.83 21.0 95.5  1.92  24.0 175 3.0 Drier 88.0 - - 200

28/08/08 383 1.90 21.0 105.5  1.80  24.0 175 3.0 Drier 87.0 - - 200

28/08/08 384 Refer to #1394/230 for 1.85 20.0 98.5  1.88  23.0 175 3.0 Drier 86.5 - - 200
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Allotment Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 2/9/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


382

383

384

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 28/8/08 JOB No.: 1394-230


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/235
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

29/08/08 393 1.86 21.5 105.0  1.77  26.5 175 4.5 Drier 82.5 - - 0

29/08/08 394 1.94 18.5 98.0 ? 1.98  21.5 175 3.0 Drier 86.5 11 0 0

29/08/08 395 Refer to #1394/236 for 1.86 20.0 102.0  1.83  23.0 175 3.5 Drier 85.5 - - 0
approx. test site
29/08/08 396 1.85 19.0 105.5  1.76  23.5 175 4.5 Drier 81.5 - - 600
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Allotment Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1. Test # 396 is a retest of test # 376.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 MICK CROWE
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Indicates APCWD Issue Date: 2/9/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


393

395

394

396

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 29/8/08 JOB No.: 1394-236


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
DAILY SUMMARY - FIELD DENSITY TESTS

GEOTECHNICAL LABORATORIES
ACN 102 571 077 REPORT NO.: # 1394/243
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036 LOCATION: SYMON BROS. - Featherbrook Estate
PH: (03) 9335 1225 Fax: (03) 9335 1775

VARIATION
HILF STANDARD STANDARD
FIELD FIELD PROBE FROM
DATE DENSITY PCWD OPTIMUM MOISTURE WET WET APPROX. DEPTH
TEST WET MOISTURE DEPTH OPTIMUM
OF TEST LOCATION RATIO OR MOISTURE RATIO +19mm +37.5mm BELOW FINISH
NUM. DENSITY CONTENT SETTING MOISTURE (%) (%) LEVEL (mm)
TESTS STANDARD APCWD CONTENT (%)
(t/m³) (%) (mm) CONTENT
(%) (t/m³) (%)
(%)

3/09/08 407 1.84 19.5 100.0  1.84  22.0 175 2.5 Drier 89.0 - - 0

3/09/08 408 1.95 18.5 108.0  1.81  21.0 175 2.5 Drier 89.0 - - 0

3/09/08 409 Refer to #1394/244 for 1.76 21.5 97.5  1.81  24.5 175 2.5 Drier 89.0 - - 0
approx. test site
- - - - -  -  - - - - - - -
locations.
- - - - -  -  - - - - - - -

- - - - -  -  - - - - - - -

NOTES: Clayey Allotment Fill Compaction specimens sampled after compaction.


Test sites located in accordance with AS 3798-1996 Level 1.
A Hilf Rapid Compaction test was carried out on a sample taken from each Field Density location to obtain the Compaction Parameters tabulated on this Report.
Compaction Curves Plotted on Pages 2 to of Moisture Content: AS 1289 2.1.1
Soil Layer thickness: 200mm Compaction Test: AS 1289 5.7.1
Hilf Density Ratio and Hilf Moisture Variation ,Hilf Adjusted (APCWD) & Peak (PCWD) Converted Wet Density AS 1289 5.7.1
Field Density, Nuclear Gauge: AS 1289 5.8.1 SAM LOZA
Materials Sampled : AS 1289 1.2.1 Clause 6.4 (Approved Signatory)
? Issue Date: 8/9/2008

™ NATA Accredited Laboratory Number 14561

Rev: 8 SS3092-1 July 2006


407

408

409

GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE: 3/9/08 JOB No.: 1394-244


LOCATION: Featherbrook Stage 7,8 & 9A OPERATOR: AB CHECKED: JC
Sketch indicating compaction test locations SCALE: NTS FIGURE No: -
Rev 0 SCI8060 Jun 1993
SYMON BROS.
CONSTRUCTION PTY LTD

FEATHERBROOK ESTATE
STAGES 7, 8, 9A

PT COOK

Report On

LEVEL 1
SURVEILLANCE
& COMPACTION CONTROL OF
ALLOTMENT FILLING

Carried Out
By

APPENDIX B
Level 1 Report Featherbrook Stage 7,8 & 9A 6
GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE:Jun 08-Sept 08 JOB No.: 1395/136


LOCATION: Featherbrook Estate OPERATOR: AB CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: 1
Rev 0 SCI8060 Jun 1993
GEOTECHNICAL LABORATORIES
ACN 102 571 077
Factory 1/8-10 Catalina Drive, Tullamarine Vic 3043
PO Box 184 Keilor VIC 3036
PH: (03) 9335 1225 Fax: (03) 9335 1775

CLIENT: Symon Bros. DATE:Jun 08-Sept 08 JOB No.: 1395/136


LOCATION: Featherbrook Estate OPERATOR: AB CHECKED: SL
Sketch indicating compaction test locations SCALE: NTS FIGURE No: 2
Rev 0 SCI8060 Jun 1993

You might also like