The document provides information about the CSENEX-I 100 current protection and monitoring system. It includes:
1. Technical specifications for the device such as voltage protection level, fault and event recording capabilities, operating temperature range, weight, and communication options.
2. Details about its features like CT input rating, drawout and self-shorting design, SCADA communication, and programmable DI/DO.
3. Protection and control functions like 3-phase time overcurrent, instantaneous overcurrent, earth fault, and circuit breaker failure protection.
4. Dimensional details, model selection chart, and ordering information.
The document provides information about the CSENEX-I 100 current protection and monitoring system. It includes:
1. Technical specifications for the device such as voltage protection level, fault and event recording capabilities, operating temperature range, weight, and communication options.
2. Details about its features like CT input rating, drawout and self-shorting design, SCADA communication, and programmable DI/DO.
3. Protection and control functions like 3-phase time overcurrent, instantaneous overcurrent, earth fault, and circuit breaker failure protection.
4. Dimensional details, model selection chart, and ordering information.
The document provides information about the CSENEX-I 100 current protection and monitoring system. It includes:
1. Technical specifications for the device such as voltage protection level, fault and event recording capabilities, operating temperature range, weight, and communication options.
2. Details about its features like CT input rating, drawout and self-shorting design, SCADA communication, and programmable DI/DO.
3. Protection and control functions like 3-phase time overcurrent, instantaneous overcurrent, earth fault, and circuit breaker failure protection.
4. Dimensional details, model selection chart, and ordering information.
16 (non volatile with time stamp) 10 (non volatile with time stamp) Fault Recorder Event Recorder 1.0 kg 0 -25 to 70 C CSENEX-I 100 CSENEX-I 100 Current Protect|on & Mon|tor|ng System Features Application Communication Test & Environments Metering & Monitoring Records The CSENEX-I over current relays have been designed for controlling, protecting & monitoring industrial, utility distribution networks & substations. They can also be used as backup protection scheme for feeders, transformers and generators against over current. 1A & 5A Rated CT input (Site selectable) Drawout with self CT shorting SCADA Communication (Local & Remote) Wide Auxiliary Supply range DI / DO Freely programmability Event Recorder Fault Recorder IEC 60255 (EMC Emission / Emmunity / Mechanical / EMI) USB Plug & Play Interface for PC / Laptop RS-485 MODBUS / IEC-103 (Remote) Operating Temperature Weight Phase Current Earth Current Unbalance Current 18-60V DC / 18-150V DC / 85-280V AC / 110-300V DC Rated Aux Voltage (UAUX) Rated Phase Current (IP) Current measuring range Rated Neutral Current (IN) 1A/5A (site selectable) 30xIp 1A/5A (site selectable) Thermal withstand Capacity At Ip = 1A Continuous = 4xIp for 10 sec = 30xIp for 1 sec = 100xIp Rated Frequency (FN) 50/60 Hz Digital Input Trip Contacts 02 Nos 04 Nos programmable : : : : : : : : Technical Data Protection & Control 3 Phase Time Over-current 3 Phase Instantaneous Current Earth Time Over-current & Instantaneous Trip Circuit Supervision Circuit Breaker Failure Protection 22 156.0 125.0 1 5 4 . 0 E L 3 L 2 L 1 ON V R E O URRE T N C ELAY R TRI P t I> CHAR I> PHASE EARTH COMM FACTORY PORT I I>> IE>> IE> I>> t IE>> t CHAR I> t IE> IE> t I s s u e
D a t e :
1 5 . 0 4 . 1 3 ,
R e v .
N o . :
0 0 ,
R e v .
D a t e :
- - - - (Panel cutout dimensions (W x H} : 112.0 x 145.0mm} CSENEX-I 100 Current Protect|on & Mon|tor|ng System Model Selection Chart Function ANSl NEX-l-100 NEX-l-101 CT inputs - 4 4 Over current 50/51 Earth fault 50N/51N CBFP 50BF Trip circuit 74TC x lnrush blocking 51H x Digital input - x 2 Digital output - 4 4 Fault record - 10 10 Event record - 16 16 Selection of 1/5A - Front communication - Rear comm. (RS-485} - (Front view} (Side view} CSENEX-I X X X X Rear Commun|cat|on CT Short|ng Rated Current -C: RS-485 Modbus communication -N: Non-Draw out (without CT shorting} -1: 1A Rated Phase & Earth Current -l: RS-485 lEC-103 Protocol -0: No communication -D: Draw out (with CT shorting} -5: 5A Rated Phase & Earth Current -S: 1A/5A Rated Phase & Earth Current site selectable -Zx: Customer specific model -: Standard model Aux Supp|y -L: 18v - 60v DC -W1: 18v - 150v DC -H: 85v - 280v AC / 110v - 300v DC X X Mode| No. -100 -101 Ordering Information Dimension Details 22