You are on page 1of 4

Fronius USA LLC - Products - Grid-Connected PV Inverters

Page 1 of 4

Fronius IG Plus V 5.0-1 UNI / 6.0-1 UNI / 7.5-1 UNI

The universal PV inverter with maximum yield. The Big Brother: This two power stage inverter is available in 5.0, 6.0 and 7.5 kW and is field programmable to 208, 240 or 277 volts. Best suited for residential and smaller commercial applications. Available Fronius IG Plus / IG Plus V Two Stage Inverters: 5.0-1 UNI 6.0-1 UNI 7.5-1 UNI

Technical Data

Fronius IG Plus
Input data
Recommended PV-Power (kWp) MPPT-Voltage range

5.0-1UNI

6.0-1UNI

7.5-1UNI

4..25-5.75 230 - 500 V

5.10-6.90

6.35-8.600

Max. Input voltage range 600 V (at 1000 W/m 14F (-10C) in open circuit operation) Nominal Input Current Max. usable Input Current Admissible conductor size (DC) 13.8 A 23.4 A No. 14-6 AWG 16.6 A 28.1 A 20.7 A 35.1 A

Output data
Nominal output power (PAC nom) Max. continupous output power 104F (40C) 208 V / 240 V / 277 V Nominal AC output voltage Operating AC voltage range (default) 208 V 240 V 277 V 5000 W 5000 W 6000 W 6000 W 7500 W 7500 W

208 V / 240 V / 277 V 183 - 229 V (-12 / +10 %) 211 - 264 V (-12 / +10 %) 244 - 305 V (-12 / +10 %)

http://www.fronius.com/cps/rde/xchg/SID-D75823CC-97333879/fronius_usa/hs.xsl/27... 30/7/2013

Fronius USA LLC - Products - Grid-Connected PV Inverters

Page 2 of 4

Maximum continuous output current 208 V 240 V 277 V Admissible conductor size (AC) Max. continuous utility back feed current Nominal frequency Operating frequency range Total harmonic distortion Power factor

24.0 A 20.8 A 18.1 A No. 14 - 4 AWG 0a 60 Hz 59.3 - 60.5 Hz <3% 1

28.8 A 25.0 A 21.7 A

36.1 A 31.3 A 27.1 A

General data
Max. Efficiency CEC Efficiency 208 V 240 V 277 V Consumption in standby (night) Consumption during operation Cooling Enclosure Type Unit Dimensions (W x H x D) Power Stage Weight Wiring Compartment Weight Admissing ambient operating temperature Compliance 96.2 % 95.5 % 95.5 % 96.0 % <1W 15 W Controlled forced ventilation, variable speed fan NEMA 3R 17.1 x 36.4 x 9.6. in. 57 lbs. (26 kg) 24 lbs. (11 kg) -13 ... 131F (-25 ... + 55C) UL 1741-2005, IEEE1547-2003, IEEE 1547.1, ANSI/IEEE C62.41, FCC Part 15 A&B, NEC Article 690, C22. 2 No. 107.1-01 (Sept. 2001) 95.5 % 96.0 % 96.0 % 95.0 % 95.5 % 96.0 %

Safety equipment
Ground fault protextion DC reverse polarity protevtion Islanding protection Over temperature Internal GFDI (Ground Fault Detector/Interrupter); in accordance with UL 1741-2005 and NEC Art. 690 Internal diode Internal; in accordance with UL 1741-2005, IEEE 1547-2003 and NEC Output power derating / active cooling

The right to make technical modifications is reserved.

Fronius IG Plus V
Input data
Recommended PV-Power (kWp) MPPT-Voltage range Max. Input voltage range (at 1000 W/m 14F (-10C) in open circuit operation) Nominal Input Current Max. usable Input Current

5.0-1UNI

6.0-1UNI

7.5-1UNI

4.25-5.75 230 - 500 V 600 V

5.10-6.90

6.35-8.60

13.8 A 23.4 A

16.6 A 28.1 A

20.7 A 35.1 A

http://www.fronius.com/cps/rde/xchg/SID-D75823CC-97333879/fronius_usa/hs.xsl/27... 30/7/2013

Fronius USA LLC - Products - Grid-Connected PV Inverters

Page 3 of 4

Admissible conductor size (DC)

No. 14-6 AWG

Output data
Nominal output power (PAC nom) Max. continupous output power 104F (40C) 208 V / 240 V / 277 V Nominal AC output voltage Operating AC voltage range (default) 208 V 240 V 277 V 5000 W 5000 W 6000 W 6000 W 7500 W 7500 W

208 V / 240 V / 277 V 183 - 229 V (-12 / +10 %) 211 - 264 V (-12 / +10 %) 244 - 305 V (-12 / +10 %)

Maximum continuous output current 208 V 240 V 277 V Admissible conductor size (AC) Max. continuous utility back feed current Nominal frequency Operating frequency range Total harmonic distortion Power factor

24.0 A 20.8 A 18.1 A No. 14 - 4 AWG 0a 60 Hz 59.3 - 60.5 Hz <3% 1

28.8 A 25.0 A 21.7 A

36.1 A 31.3 A 27.1 A

General data
Max. Efficiency CEC Efficiency 208 V 240 V 277 V Consumption in standby (night) Consumption during operation Cooling Enclosure Type Unit Dimensions (W x H x D) Power Stage Weight Wiring Compartment Weight Admissing ambient operating temperature Compliance 96.2 % 95.5 % 95.5 % 96.0 % <1W 15 W Controlled forced ventilation, variable speed fan NEMA 3R 17.1 x 38.1 x 9.9. in. 57 lbs. (26 kg) 24 lbs. (11 kg) -13 ... 131F (-25 ... + 55C) UL 1741-2010, IEEE1547-2003, IEEE 1547.1, ANSI/IEEE C62.41, FCC Part 15 A&B, NEC Article 690, C22. 2 No. 107.1-01 (Sept. 2001), California Solar Initiative - Program Handbook Appendix C: Inverter Integral 5 % Meter Performance Specification 95.5 % 96.0 % 96.0 % 95.0 % 95.5 % 96.0 %

Safety equipment
Ground fault protextion DC reverse polarity protevtion Islanding protection Over temperature Internal GFDI (Ground Fault Detector/Interrupter); in accordance with UL 1741-2005 and NEC Art. 690 Internal diode Internal; in accordance with UL 1741-2010, IEEE 1547-2003 and NEC Output power derating / active cooling

http://www.fronius.com/cps/rde/xchg/SID-D75823CC-97333879/fronius_usa/hs.xsl/27... 30/7/2013

Fronius USA LLC - Products - Grid-Connected PV Inverters

Page 4 of 4

The right to make technical modifications is reserved.

http://www.fronius.com/cps/rde/xchg/SID-D75823CC-97333879/fronius_usa/hs.xsl/27... 30/7/2013