Field Communicator Menu Tree

11 1 Device Status 1Refresh Alerts 2No Active Alerts 14 Primary Variable 1PV Value 2% Range 16 Process Temperature 1Proc Temp Source 2Proc Temp 1-7 Device Information 1Identification 2Revisions 3Alarm Type and Security

DLC3010 Digital Level Controller


17-1 Identification 1HART Tag 2Distributor 3Model 4Device ID 5Instrument Serial Number 6Sensor Serial Number 7Final Assembly Number 8Date 9Descriptor 9Message 17-3 Alarm Type and Security 1Alarm Type 2Security 22 Manual Setup 24 Communications 1Burst Mode 2Burst Options 1Sensor 2Variables 3Process Fluid 4Identification 5Instrument Display 225 Instrument Display 25-1-3 Partial Calibration 1Capture Zero 2Trim Gain 3Trim Zero 25-1-2 Full Calibration 1Min/Max Calibration 2Two Point Calibration 3Weight Calibration 1LCD Configuration 2Display Mode 3Change Display Mode 4Decimal Places 224 Identification 17-2 Revisions 1HART Universal Revision 2Field Device Revision 3Firmware Revision 4Hardware Revision 5DD Information 17-3-1 Alarm Types 1Alarm Jumper 2Display Alert/Saturation Level 17-3-2 Security 1Write Lock 2Write Lock Setup

Menu Tree applies to


Device Revision 1 Hardware Revision 1 Firmware Revision 8 DD Revision 3

FIELDVUE DLC3010 Digital Level Controller


www.Fisher.com For the telephone number of the Emerson Process Management sales office nearest you, contact: In North America Fisher Controls International LLC 1 (641) 7543011 In Latin America Fisher Controls International LLC 1 (314) 7469900 In Asia Pacific Emerson Process Management Asia Pacific Private Ltd. (65) 67778211 In Europe Emerson Process Management Ltd. +44 1634 895800
475 Field Communicator

Hot Key 1Write Lock 2Write Lock Setup 3Change PV 4Enter Contstant Density Online 1Overview 2Configure 3Service Tools 3 Service Tools 1Active Alerts 2Variables 3Maintenance

Overview 1Device Status 2Comm Status 3PV is 4Primary Variable 5AO 6Process Temperature 7Device Information

221-1 Sensor Units 1Length Units 2Volume Units 3Weight Units 4Torque Rate Units 5Temperature Units 221-2 Sensor Dimensions 1Displacer Length 2Displacer Volume 3Displacer Weight 4Driver Rod Length

21 Guided Setup 1Instrument Setup 2 Configure

22-1 Sensor 1Sensor Units 2Sensor Dimensions 3Torque Tube 4Instrument Mounting 5Sensor Damping 221-3 Torque Tube 1Torque Rate 2Change Torque Rate 3TT Material 4TT Comp Selection 5TT Comp Table 222 Variables 1Primary Variables 2Sensor Limits 3Primary Variable Range 4PV Damping 22-3 Process Fluid (if PV is Level or Interface) 1Process Fluid 2Process Temperature

DLC3010 Digital Level Controller

3-3 Maintenance 1Tests 2Reset/Restore 3-3-1 Tests 1LCD Test 1 2Loop Test 3-3-2 Reset/Restore 1Restore Factory Defaults 2Reset Device 3-3-2-1 Restore Factory Defaults 1Restore Factory Configuration 2Restore Factory Compensation
1 2 3 4

1Guided Setup 2Manual Setup 3Alert Setup (See Reverse Side) 4Communications 5Calibration Calibration 25 25-1 Primary 1Guided Calibration 2Full Calibration 3Partial Calibration 25-2 Secondary

If PV is Density

1Primary 2Secondary 3-1 Active Alerts 2 1No Active Alerts 1Refresh Alerts 3-2 Variables

If PV is Level or Interface

222-1 Primary Variables 1PV is 2Change PV 3PV Units 4Level Offset 5Set Level Offset 222-2 Sensor Limits 1Upper Sensor Limit 2Lower Sensor Limit 3Minimum Span 222-3 Primary Variable Range 1Upper Range Value 2Lower Range Value 3View/Change AO Action

For equipment service or support needs, contact your local Emerson Process Management sales office

www.Fisher.com
D102732X012 October 2012 FIELDVUE and Fisher are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson, Emerson Process Management, and the Emerson logo are trademarks and service marks of Emerson Electric Co.
2005, 2012 Fisher Controls International LLC. All rights reserved.

1Temperature Calibration 1PV 2Analog Output Calibration 2Primary Variable 3AO 25-2-2 4Inst Temp Analog Output Calibration 5Process Temperature 1Scaled D/A/ Trim 6Torque Rate 7Upper Fluid Density 3 25-2-1 8Lower Fluid Density 4 Temperature Calibration 1Trim Instrument Temperature 2Trim Processs Temperature 2(Visible if Process Temperature 2 is not Manual)

LCD Test is visible if LCD Configuration is installed. No Active Alerts visible if there are no active alerts. Refresh Alerts visible if an alert is active. Upper Fluid Density visible if PV is Interface. Lower Fluid Density visible if PV is Interface or Level.

1HART Tag 1Proc Temp Source 2Date 2Change Proc Temp 3Descriptor 3Proc Temp 4Message 4RTD Wire Resistance 5Polling Address 6Physical Signaling Code 7Number of Request Preambles 8Serial Numbers

22-3 Process Fluid (if PV is Density)

224-8 Serial Numbers 1Instrument Serial Number 2Sensor Serial Number 3Final Assembly Number

Alert Setup
2 Configure
1Guided Setup 2Manual Setup 3Alert Setup 4Communications 5Calibration

23
Alert Setup 1Primary Variable 2Temperature

Function/Variable Active Alerts Alarm Jumper 23-1


Primary Variable 1Primary Variable Hi 2Primary Variable Lo 3Upper Range Value 4Lower Range Value 5PV Alerts Threshold 5Deadband

Analog Output Burst Mode Burst Options Calibration, Guided Calibration, Min/Max Calibration, Partial, Capture Zero Calibration, Partial, Trim Gain Calibration, Partial, Trim Zero Calibration, Temperature Calibration, Two Point Calibration, Weight Change Process Temperature

23-2
Temperature 1Instrument Temperature 2Process Temperature

23-2-2
Process Temperature 1Hi Alert 2Lo Alert 3Proc Temp 4Proc Temp Offset 1Lo Alert 2LoLo Alert

23-1-2
Primary Variable Lo

23-1-1
Primary Variable Hi 1Hi Alert 2HiHi Alert

23-2-2-2
Lo Alert 1Proc Temp Lo Alert Enable 2Proc Temp Lo Alert Threshold

23-1-1-2
HiHi Alert 1PV HiHi Alert Enable 2PV HiHi Alert Threshold 3PV HiHi Alert Threshold

Change Primary Variable Change Torque Rate Comm Status Date DD Information Decimal Places Descriptor Device ID Device Status Display Alert/Saturation Level Display Mode Distributor Enter Constant Density Field Device Revision Final Assembly Number Firmware Revision Guided Setup Hardware Revision

23-2-2-1
Hi Alert 1Proc Temp Hi Alert Enable 2Proc Temp Hi Alert Threshold

23-1-1-1
Hi Alert 1PV Hi Alert Enable 2PV Hi Alert Threshold 3PV Hi Alert Threshold

23-2-1
Instrument Temperature 1Hi Alert 2Lo Alert 3Inst Temp 4Inst Temp Offset

23-1-2-1
Lo Alert 1PV Lo Alert Enable 2PV Lo Alert Threshold 3PV Lo Alert Threshold

23-2-1-2
Lo Alert 1Inst Temp Lo Alert Enable 2Inst Temp Lo Alert Threshold

23-2-1-1
Hi Alert 1Inst Temp Hi Alert Enable 2Inst Temp Hi Alert Threshold

23-1-2-2
LoLo Alert 1PV LoLo Alert Enable 2PV LoLo Alert Threshold 3PV LoLo Alert Threshold

Italics text indicates Method

FastKey Sequence 3-1 1-7-3-1-1 1-5 3-2-3 2-4-1 2-4-2 2-5-1-1 2-5-1-2-1 2-5-1-3-1 2-5-1-3-2 2-5-1-3-3 2-5-2-1 2-5-1-2-2 2-5-1-2-3 2-2-3-2(1) 2-2-3-2-2(2)(3) Hot Key-3 2-2-2-1-2 2-2-1-3-2 1-2 1-7-1-8 2-2-4-2 1-7-2-5 2-2-5-4 1-7-1-9 2-2-4-3 1-7-1-4 1-1 1-7-3-1-2 2-2-5-2 1-7-1-2 Hot-Key-4 2-2-3-1-3(2)(5) 2-2-3-1-4(2)(6) 1-7-2-2 1-7-1-7 2-2-4-8-3 1-7-2-3 2-1 1-7-2-4

Function/Variable HART Tag HART Universal Revision Instrument Mounting Instrument Serial Number Instrument Temperature Instrument Temperature (Alert Setup) LCD Configuration LCD Test Level Offset Loop Test Lower Density Table(3)

Lower Fluid Density

Lower Range Value Lower Sensor Limit Measure Density Message Minimum Sensor Span Model (Device) Number of Request Preambles Percent Range Physical Signalling Code Polling Address Primary Variable Hi (Alert Setup) Primary Variable Lo (Alert Setup)

Process Temperature Process Temperature (Alert Setup) Process Temperature Source

FastKey Sequence 1-7-1-1 2-2-4-1 1-7-2-1 2-2-1-4 1-7-1-5 2-2-4-8-1 3-2-4 2-3-2-1 2-2-5-1 3-3-1-1(4) 2-2-2-1-4 3-3-1-1 3-3-1-2(4) 2-2-3-1-2-1(3)(5) 2-2-3-1-3-2(3)(6) 2-2-3-1-1(3)(5) 2-2-3-1-2(3)(6) 3-2-7(5) 3-2-8(6) 2-2-2-3-2 2-3-1-4 2-2-2-2-2 2-2-3-1-4(3)(5) 2-2-4-4 2-2-2-2-3 1-7-1-3 2-2-4-7 1-4-2 3-2-2-2(3) 2-2-4-6 2-2-4-5 2-3-1-1 2-3-1-2 1-6-2 2-2-3-2-3(2)(3) 2-2-3-3(1) 3-2-5-2(3) 2-3-2-2 1-6-1 2-2-3-1(1)

Function/Variable Process Temperature Source PV Alerts Threshold Deadband PV Damping PV is PV Units PV Value Reset Device Restore Factory Defaults RTD Wire Resistance Scaled D/A Trim Sensor Damping Sensor Dimensions (Displacer Units) Sensor Serial Number Sensor Units Set Level Offset Torque Rate Torque Tube Compensation Selection Torque Tube Compensation Table Torque Tube Material Upper Density Table Upper Fluid Density Upper Range Value Upper Sensor Limit View/Change AO Action Write Lock Write Lock Setup
1. If PV is Density 2. If PV is Level or Interface 3. Not included in menu tree 4. LCD Configuration is installed 5. If PV is Level 6. If PV is Interface

FastKey Sequence 2-2-3-2-1(2)(3) 2-3-1-5 2-2-2-4 1-3 2-2-2-1-1 2-2-2-1-3 1-4-1 3-2-2-1(3) 3-3-2-2 3-3-2-1 2-2-3-2-4(2)(3) 2-2-3-4(1) 2-5-2-2-1 2-2-1-5 2-2-1-2 1-7-1-6 2-2-4-8-2 2-2-1-1 2-2-2-1-5 2-2-1-3-1 3-2-6 2-2-1-3-4 2-2-1-3-5 2-2-1-3-3 2-2-3-1-3-1(3)(6) 2-2-3-1-1(3)(6) 3-2-7(6) 2-2-2-3-1 2-3-1-3 2-2-2-2-1 2-2-2-3-3 Hot Key-1 1-7-3-2-1 Hot Key-2 1-7-3-2-2