Volumetric flow sensor efector mid. High-precision measurement, display and signalling of liquid media.
Coolant monitoring
Condition-based maintenance.
The diagnostic functionality of efector mid, e.g. analogue outputs, binary limit values, consumed quantities during the specified period or temperature monitoring in the medium, enables the reliable operation of cooling circuits and systems. Due to the continuous monitoring the sensor can be perfectly integrated into the condition-based maintenance concepts. This enhances the reliability of the plant; uptime is increased. Expensive consequential damage resulting from lack of coolant is prevented. By integration into a real-time-maintenance concept maintenance can be implemented at the right time, in the right place, using the right material and operators.
industrial water
electrical conductivity
Photo reference Induction hardening: R. Rieker GmbH, Leingarten Wafer production: centrotherm thermal solutions GmbH+Co KG, Blaubeuren
efector mid the reliable and lowcost solution for monitoring the exact supply and consumption of liquids in industrial processes. Due to the measuring range of 0 to 25 l/min and an accuracy of 2 % of the measured value the unit can be used in a wide range of applications. Volumetric flow in the opposite direction is also indicated.
Short-circuit protection, pulsed Reverse polarity, overload prot. Analogue output Flow monitoring Measuring range [l/min / m3 /h] Measurement error [%] Setting range [l/min / m3 /h] Set point, SP Analogue start point, ASP Analogue end point, AEP Start-up delay Temperature monitoring Measuring range Measurement error [s] [C] [C]
Setting range [C] Set point, SP Analogue start point, ASP Analogue end point, AEP Pressure resistance Medium temperature Display unit Output status Measured values Programming Protection Housing materials Sensor materials Connection [bar] [C]
Sockets
Description Order no. EVC004 EVC005
110 73
54
2 m PUR, M12 angled, without LED 5 m PUR, M12 angled, without LED
G1 2
Accessories (selection)
Description Order no.
G1 2
16
M12 x1
M12 x1
Adapter G 1/2 - R 3/4 Process connection G 3/4 flat seal Adapter G 1/2 - R 1/2 Grounding clamp
Volumetric flow sensor efector mid: Simultaneous monitoring of volumetric flow quantity and temperature of conductive liquids. Functionality and precision at the right price. Local indication of the current volumetric flow quantity, total quantity and temperature. For external evaluation: Switching, pulse and analogue outputs for signal and control tasks. Less cost: Setting and monitoring of cooling circuits for optimum performance. More safety: Immediate detection of even very small leaks. High transparency: Counting and allocation of consumed quantities. Exactly right: Exact determination of liquid quantities.
M
M = magnet E = electrodes V = flow velocity converted in the evaluation electronics. As the pipe cross-section is defined, the volumetric flow quantity can be determined exactly. No moving components are used, therefore the system works reliably, wear and maintenance free.
Overview ifm main catalogues: Position sensors and object recognition Inductive sensors Capacitive sensors Magnetic sensors, cylinder sensors Safety technology Valve sensors Photoelectric sensors Object recognition Encoders Evaluation systems, power supplies Connection technology Fluid sensors and diagnostic systems Level sensors Flow sensors Pressure sensors Temperature sensors Diagnostic systems Evaluation systems, power supplies Connection technology Bus systems Bus system AS-Interface Power supplies Connection technology Identification systems DataMatrix code-reading systems RF-identification systems Power supplies Connection technology Control systems Control systems for mobile vehicles Connection technology