You are on page 1of 6

Suction Filters

Tank top mounting

10.50-1e

ES 134 ES 144
Connection Nominal flow rate up to up to SAE 1 130 l/min

Q ua lit y

m an ag em en t

ac co rd in g

to

DI N

EN

IS O

90 01

Description
Application To be installed in the suction line of the pumps of hydraulic systems resp. upstream of the charge pumps of hydrostatic drives. Performance features Protection against wear: By means of filter elements that, in fullflow filtration, meet even the highest demands regarding cleanness classes. Protection against malfunction: By means of full-flow filtration in the system return, the pumps above all are protected from dirt particles remaining in the system after assembly, repairs, or which are generated by wear or enter the system from outside. Special features By-pass valve: The location close to the suction inlet prevents dirt particles retained by the filter element from entering into the clear oil side. Ensures that dirt accumulated in the filter element is removed together with the element and cannot return to the tank. When the screw-on cover is removed for maintenance, the foot valve closes automatically. This makes it possible to service the filter even if it is submerged below the oil level in a full tank. Filter elements Flow direction from outside to centre. The star-shaped pleating of the filter material results in: large filter surface high dirt-holding capacity low pressure drop long service life In filters with a magnetic system, the ferromagnetic particles in the fluid pass first through a strong magnetic field and are separated. Filter maintenance By using a clogging indicator the correct moment for maintenance is stated and guarantees the optimum utilization of the filter elements. Materials Screw-on cap: Filter head: Filter bowl: Seals: Filter media: Polyester, GF reinforced Aluminium alloy Steel NBR (Viton on request) Paper - cellulose web, impregnated with resin Stainless steel wire mesh (1.4301)

Filter element locking valve:

Accessories Electrical and optical clogging indicators are available. Dimensions and technical data see Spec. Sheet 60.20.

Foot valve:

Characteristics
Nominal flow rate Up to 130 l/min (see Selection Chart, column 2) The nominal flow rates indicated by ARGO are based on the following features: closed by-pass valve at 200 mm2/s element service life 1000 operating hours at an average fluid contamination of 0,08 g per l/min flow volume flow velocity in the connection lines 1,5 m/s If units not equipped with a bypass valve are used in hydrostatic drives, the recommendations regarding their technical application given on data sheet 10.310 should be observed. Connection Threaded ports according to ISO 228 resp. DIN 13 or SAE-flange (3000 psi). Sizes see Selection Chart, column 6 (other connections on request) Filter fineness 10 m ... 60 m -values according to ISO 4572-81 (see Selection Chart, column 4 and Diagram Dx) ACFTD capacity -values in g test dust ACFTD according to ISO 4572-81 (see Selection Chart, column 5) Hydraulic fluids Mineral oil and biodegradable fluids (HEES or HETG,see info-service 00.20) Temperature range - 30 C ... + 100 C (- 40 C in starting phase) Viscosity at nominal flow rate < 60 mm2/s at operating temperature start-up viscosity: determine max, observing the permissible pressure at the pump inlet according to diagram D; determine p as a function of the viscosity (take into account the pressure loss in the connecting lines!) on initial operation of units equipped with a bypass valve: max. 70% of the pressure relief valve opening viscosity (indicated by the bend in the p characteristic, refer to diagrams) Mounting position Vertical mounting to be preferred, suction opening pointing downwards, versions equipped with foot valve for horizontal mounting also

10.50-1e

2/6

Diagrams
p-curves for complete filters in Selection Chart, column 3

D1

Pressure drop as a function of the flow volume at = 35 mm2/s (0 = casing empty)

Pressure drop as a function of the kinematic viscosity at nominal flow

p [bar]

p [bar]

Q [l/min]

[mm2/s] Pressure drop as a function of the kinematic viscosity at nominal flow

D2

Pressure drop as a function of the flow volume at = 35 mm2/s (0 = casing empty)

p [bar]

p [bar]

Q [l/min]

[mm2/s]

Filter fineness curves in Selection Chart, column 4

Dx

Filtration ratio as a function of particle size x obtained by the Multi-Pass-Test similar to ISO 4572-81
The abbreviations represent the following -values resp. finenesses: For Exapor and Paper elements: 3E 10 E 15 E 20 E = = = = 3 10 15 20 75 Exapor (3 m abs.) 75 Exapor (10 m abs.) 75 Exapor (15 m abs.) 75 Exapor (20 m abs.) Paper (10 m nom.) Paper (15 m nom.)

10 PA = 15 P =
Filtration ratio for particles > x m Efficiency [%]

Based on the structure of the filter media of the 10 PA and 15 P paper elements, deviations from the printed curves are quite probable. For screen elements: 40 S = screen material with mesh size 40 m 60 S = screen material with mesh size 60 m 75 S = screen material with mesh size 75 m 100 S = screen material with mesh size 100 m Tolerances for mesh size according to DIN 4189. For special applications, finenesses differing from these curves are also available by using special composed filter media.

Dotted characteristics apply if pEnd = 0,25 bar

Particle size x [m] (for particles larger than the given particle size x) 10.50-1e 3/6

Selection Chart
it un ) flo al w y () cit e in B a p n ca rfac tio c u D e FT er s nn AC Filt Co m ele en t

t ar

No

B .(

as

ic

i om

Sy

o mb

nt me . e c o t pla rt N igh e e a R P W

a em

rks

l/min 1 2 3 D1/1 D1/2 4

g 5 6 SAE 1 SAE 1

bar 7 -0,25 -0,25 8 9 6 6 10 S2.0920-05 S2.0920-10

kg 11 3,0 3,0 12
with magnetic system with magnetic system

ES 134-0501 130 ES 134-0001 130

40S (1540 cm2)


60S (1540 cm2)

ES 144-6110 70*

D2/1

10 PA

30

2xG1 + G 1

P2.0933-01

3,5

All filters are delivered with a plugged clogging indicator connection G. As clogging indicators either manometers or vaccum switches can be used. Order example: The filter E 074-6110 has to be supplied with an extension pipe for a mounting depth of 400 mm. Order description: Part No. (Basic unit) Mounting depth ET (mounting depth) in mm, according to chapter "Dimensions" The following clogging indicators are available: Part No. DG 100-00 Manometer red area from DG 101-04 Manometer red area from DG 902-11 Vaccum switch switching pressure DG 902-12 Vaccum switch switching pressure Technical data see Spec. Sheet 60.20. ES 134-0501 / ET 400

-0,25 -0,25 -0,15 -0,25

bar bar bar bar

fitting on the back bottom fitting

Remarks: The start of the red area respectively the actuating pressure of the vaccum switch has always to be higher than the cracking pressure of the by-pass valve (see Selection Chart, column 7). The clogging indicators are always delivered detached from the filter. The filters listed in this chart are standard filters. Other designs available on request.
* Those values apply when used in hydrostatic drives and instructions in datasheet 10.310 have to be observed 10.50-1e 4/6

Dimensions
, , , , , , , , , , , , , , , , , , , , , ,

ES 134
Suitable SAE - flange to be ordered separately ARGO Part-No. N036.0401

ES 144

Design without foot valve Groove for O-ring 126 x 4 O-Ring Part No. N007.1264 on request Groove for O-ring 126 x 4 O-Ring Part No. N007.1264 on request Design with 3 inlet ports Connection G for clogging indicator Required mounting surface
min./max.

Design with 1 inlet port

Measurements
Type A B SAE 1 G 1, G 1 P 13 13 B1 B2 C D E F 12 12 V G 32 32 W H I K K1 K2 L M 10 10 N 62,5 62,5

ES 134 100 ES 144 115 Type O ES 134 11,5 ES 144 11,5

111/121 126,5 110 G, G1 G, G1 119/121 126,5 Q R S T U 165 165 81 81 82 82

106 400 198 256 218 106 525 305 364 325

144 69,8 35,7 M12 144 69,8 35,7 M12

Symbols
1 2 3 4 5 6

10.50-1e

5/6

Spare Parts
1 3a 3b Pos. 1 2 2 3a Designation Screw cap (with Pos. 2) O-ring 100 x 4 Screw cap assy (with Pos. 2) ES 134 (without by-pass) ES 144 (without by-pass) 3b Cover complete including
magnetic system (with Pos. 2)

Part No. ES 074.1212 N 007.1004 ES 074.1213 ES 094.1212

ES 134 (with by-pass) 4 5 6 7 4 6 Filter element Valve cone O-ring 126 x 4 * Rubber ring

ES 074.1205 see Chart / col. 10 ES 074.0202 N 007.1264 N 042.7401

*Not included in basic equipment

The functions of the complete filters as well as the outstanding features of the filter elements assured by ARGO can only be guaranteed if original ARGO spare parts are used.

Quality Assurance
To ensure constant quality in production and operation, ARGO filter elements undergo strict controls and tests according to the following DIN and ISO standards: DIN ISO 2941-83 Verification of collapse/burst resistance DIN ISO 2943-90 Verification of material compatibility with fluids DIN ISO 3724-90 Verfication of flow fatigue characteristics ISO 2942-94 Verification of fabrication integrity (Bubble Point Test) ISO 3968-81 Evaluation of pressure drop versus flow characteristics ISO 4572-81 Multi-pass method for evaluating filtration performance Various quality controls during the production process guarantee the leakfree function and solidity of our filters.

Our engineers will be glad to advice you in questions concerning filter application, selection as well as the cleanness class of the filtered medium attainable under practical operating conditions.
Illustrations may sometimes differ from the original. ARGO is not responsible for any unintentional mistake in this specification sheet.

FSP Fluid Systems Partners GmbH


ARGO Filtration Division D-76703 Kraichtal / Germany Tel. E-Mail +49-(0) 7250-76-0 argo@fluid-systems-partners.de Fax +49-(0) 7250-76-199 Internet www.argo.de
10.50-1e 6/6

Subject to change 9107162-e / 06.99