You are on page 1of 12

The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and

liquid chemicals. Consisting of four distinct families, the range is able to meet the needs of most industrial metering applications.

Flowmeters
Positive Displacement meter Coriolis mass flowmeter Turbine flowmeter Ultrasonic flowmeter

Areas of activity: Oil depots Metering for road tankers Aviation Transport via pipeline

Positive Displacement meter

ZC17
The SATAM Positive Displacement meter (PD meter) is a system with freely-moving blades used to measure "white" petroleum products such as fuels, bio-fuels and refined liquid hydrocarbons. Its simple design using only two pairs of blades and one moving rotor makes it exceptionally robust and allows the user to make significant savings on maintenance costs.

Sectors of application
Oil depots For product reception and loading stations for trucks, wagons and ships Hydrocarbon transportation Distribution of fuel oil or fuel by road tanker Aircraft refuelling Aircraft dispensers and aircraft fuelling tankers Army Depot supplies and loading of trucks Transport companies Refuelling of locomotives, trucks and public transport coaches Marine applications Refuelling of ships Mining sites Refuelling of trucks or site machinery

Key points
> Reduced pressure loss 0,3 to 0.5 bar at maximum flow rate > Low maintenance costs Simple and robust design with mechanical components interchangeable between the different models > Stability of measurements Accuracy of measurement guaranteed over a period of many years without any drift in the calibration curve > Modular design Wide range of accessories for performing customized measurement applications > Robust construction Flowmeter manifold separated from measurement chamber to eliminate any possible influence of external mechanical stresses on measurement. Few moving parts

Positive Displacement meter ZC17

Technical specifications
Model
Maximum flowrate (m3/h) (l/mn) (USGPM) Minimum flowrate (m /h)
3

ZC17 12
12 200 53 1,2 20 5,3

ZC17 24
24 400 105 2,4 40 10,5

ZC17 48
48 800 210 4,8 80 21

ZC17 80
80 1333 360 8 133 36

ZC17 150
150 2500 660 15 250 66

ZC17 250
250 4166 1100 25 416 110

(l/mn) (USGPM) Application Connection - Flanges Materials Diameter Manifold Casing Front and back flanges Rotor Blades Gaskets Operating conditions Pressure Viscosity Liquid temperature Ambient temperature Pressure drop Internal construction Cyclic volume (litres) (US gallons) Metrological performance Accuracy Mass repeatability Installation Custody transfer approval Straight inlet and outlet sections

Multi-product metering 2 2 Aluminium Aluminium 2 3 4 6 Steel

Steel or aluminium Ductile iron or Ni resist iron Kanigen-plated steel Aluminium Graphite Viton (option nitrile) 0 to 10 bar / 0 to 150 PSI Max. 800 mPa.s/ 800 cPo / 3850 SSU -40C (-40F) +60C (+140F) -40C (-40F) +60C (+140F) Max. 0.5 bar

0,33 0,08

0,40 0,10

0,80 0,21

2,27 0,6

4,54 1,12

6,82 1,8

< 0.15% / Option< 0.1% / For 10:1 measuring range < 0,02 % Not necessary EC Evaluation Certificate N LNE - 11052

Weight and dimensions


Model
Distance between flanges (mm) (inches) Width (mm) (inches) Depth (mm) (inches) Height (mm) (inches) Weight net kg (lbs) Gross kg (lbs)

ZC17 12
180 7 180 7 215 8,5 221 8,7 14 (31) 32 (71)

ZC17 24
180 7 287 11,3 235 9,3 406 16 20 (44) 38 (84)

ZC17 48
180 7 287 11,3 269 10,6 406 16 25 (55) 43 (95)

ZC17 80
356 14 356 14 370 14,6 406 16 56 (123) 95 (209)

ZC17 150
432 17 432 17 497 19,6 405 16 85 (187) 124 (273)

ZC17 250
400 15,7 400 15,7 675 26,6 568 22,4 141 (311) 180 (387)

Coriolis mass flow meter

MFM
The Satam mass flowmeter is used to measure the mass and density of viscous products such as heavy fuel oil, engine oil, bitumen or crude oil. Its excellent pressure resistance qualities combined with its straight tube design without any moving mechanical parts means it is capable of providing reliable and accurate measurements for liquid gases such as LPG.

Sectors of application
Oil depots For product reception and at loading stations for trucks, wagons and ships Oil production Metering for transfers of products via pipeline Marine applications Loading and unloading of tankers Refineries Internal metering and control of manufacturing processes Fuel storage Metering of heavy fuel oil at mixer intake

Key points
> Direct measurement of mass Direct measurement without any correction for temperature or viscosity > Reliability of measurements Strain gauges for correction of dilatation effects related to temperature changes > Flexibility of installation Patented construction allowing the system to be supported by its own housing or on the inlet and outlet pipes > Low maintenance costs Simple and robust design without any moving mechanical parts > Direct measurement of density Identification of liquid being measured and detection of any change of product

Coriolis mass flow meter MFM

Technical specifications
Models
Mass flowrate Maximum flowrate (kg/h) (kg/mn) Minimum flowrate (kg/h) (kg/mn) Applications Connection - Flanges Pressure class Diameter Materials Measurement tube Secondary containment and flanges Operating conditions Pressure Viscosity Liquid temperature Ambient temperature Pressure drop Internal construction Max. 100 mPa.s -40 +100C -40 to +60C 1 bar (at maximum flowrate, 1 mPa.s) Single straight tube 318L stainless steel 304 stainless steel 0 to 63 bar Unrestricted -40 +150C

MFM S
430 000 7 167 480 8

MFM T

Multi-product metering for low viscosity products Multi-product metering and measurement of density 150lbs RF (standard), 300lbs, 600lbs, 900lbs RF & RTJ (optional) 3/4 to 4 Grade 9 titanium

Measurement tube Single straight tube (S50 and S80) Dual straight tube (S15, S25, S40) Measurement converter MFC300 < 0.2% + zero stability

Metrological performance

Mass accuracy Mass repeatability Density accuracy Temperature accuracy Zero stability

< 0.1% + zero stability

< 0.025% + zero stability < 0.002 g/cm3 < 0.0005 g/cm3 after on site calibration 0,5C < 0.025% of sensor max. flowrate < 0.008% of sensor max. flowrate sensor

Installation

Straight inlet and outlet sections Protection class EX approval

Not necessary IP 67, equivalent to NEMA 6 EEx d e [ib] IIC T6

Measuring range - Weight and dimensions


Measuring range Min. flowrate Max. flowrate MFM 7000 (kg/h)
T15 T25 T40 T50/S50 T80/S80 1 125 3 450 9 150 18 000 43 000

Weight and dimensions A (mm)


102 115 169 219 273

B (mm)
311 317 344 370 398

E (mm)
548 700 925 1101 1460

Weight (kg)
23 35 80 145 260

(kg/h)
11 250 34 500 91 500 180 000 430 000

MFM 1000
S15 S25 S40 S50 480 2 000 6 000 12 500 4 800 20 000 60 000 125 000 102 114 169 219 311 317 344 370 520 565 742 896 13,5 16,5 29,5 57,5

Turbine flowmeter

SA-LM-ZN
The Satam turbine flowmeter is primarily used for high-capacity metering. Its 500mm measurement tube can accurately measure at flowrates of over 3000 m3/h. Its excellent pressure and temperature resistance qualities means it is capable of providing reliable and accurate measurements for liquid gases such as LPG, as well as for cryogenic liquids. The SA model comes fitted with a straight-bladed rotor. It is intended for use with single-product lowviscosity applications. The LM and ZN models come fitted with a two-bladed helical rotor. This construction ensures low sensitivity to variations in viscosity.

Sectors of application
Marine applications Loading and unloading of tankers Oil production Metering for transfers of crude oil and condensate via pipeline Oil depots For product reception and at loading stations for wagons and ships Refineries Internal metering and control of manufacturing processes

Key points
> Low maintenance costs Simple and robust design with interchangeable mechanical components > Stability of measurements Not sensitive to variations in pressure. Integrated flow straightener > Wide range of uses Available for liquid and for gas from 10 l/h to 6 000 m3/h

Turbine flowmeter SA-LM-ZN

Technical specifications
Model SA
1,36 to 3 406 m3/h 6 to 15 000 USGPM Single-product Pressure class Diameter Materials Measurement tube & flanges Bearings Turbine rotor Operating conditions Pressure Viscosity Liquid temperature without preamplifier Liquid temperature with preamplifier Pressure drop (1 mPa.s, Qmax) Internal construction Turbine rotor Pulser Preamplifier Measurement chamber Metrological performance Volume accuracy Repeatability Installation Straight sections Protection class EX approval Inlet 10 DN / Outlet 5 DN IP65 EEx ia IIC T6 Fixed < 1 bar Straight multi-blade 1 or 2 ANSI 150 to ANSI 1500 DN 25 to DN 300 1" to 12

LM
3 to 300 m3/h 13 to 1320 USGPM Single and multi-product ANSI 150 ANSI 300 DN 50 to DN100 2" to 4 316L stainless steel (other materials available on request)

ZN
0,012 to 6 000 m3/h 0,05 to 26 400 USGPM Single and multi-product ANSI 150 to ANSI 2500 DN10 to DN 500 1/2" to 20

Flow rate Application Connection - Flanges

Ceramic, tungsten carbide 304 L stainless steel 0 to 200 bar 0,1 to 10 cSt -270 to +230C

Graphite, tungsten carbid Aluminium / Titanium (optional) 0 to 40 bar 0,1 to 15 cSt -40 to +180C -20 to 80C < 1 bar Helical twin-blade 2 Optional Removable < 0.15% < 0.02% Inlet 0 DN / Outlet 0 DN IP65 EEx ia IIC T6 and EEx d ia II C T6

Graphite, tungsten carbid Aluminium / Titanium (optional) 0 to 420 bar 0,1 to 1000 cSt -40 to +180C

< 0,8 bar Helical twin-blade 2

Removable

Inlet 10 DN / Outlet 5 DN IP66 EEx ia IIC T6 and EEx d ia II C T6

Measuring range
SA model Nominal diameter
Min. flowrate m3/h 1/2 1 11/2 2 21/2 3 4 6 8 10 12 14 16 18 20 1,36 2,95 5,1 40 65 28,4 65,9 118 182 273 USGPM Max. flowrate m3/h 13,6 29,5 51 400 650 284 659 1180 1820 2730 USGPM

LM model
Min. flowrate m3/h 3 5 30 USGPM Max. flowrate m3/h 30 50 300 USGPM

ZN model
Min. flowrate m3/h 0,012 0,2 0,8 3 7 20 40 80 120 240 350 400 480 600 USGPM 0,053 0,88 3,52 13,2 30,8 880 176 352 528 1056 1541 1760 2113 2642 Max. flowrate m3/h 0,12 2 8 30 70 200 400 800 1200 2400 3500 4000 4800 6000 USGPM 0,53 8,8 35,2 132 308 8800 1760 3520 5280 10560 15410 17600 21130 26420

6 13 22,4 176 286 125 290 520 801 1202

60 130 224 1760 2860 1250 2900 5200 8010 12020

13,2 22 132

132 220 1320

Ultrasonic flowmeter

UFM III
The Satam ultrasonic flowmeter is used for measuring refined petroleum liquids. It is capable of measuring high-pressure fluids such as LPG or any other liquid gas. Its measurement tube without any intrusive elements or moving mechanical parts results in very little pressure drop and nearly no maintenance costs at all. Because of the measurement method used, ultrasonic flowmeters are available in diameters of up to 40 inches and provide exceptional accuracy of measurement.

Sectors of application
Transport of petroleum products via pipeline Metering stations, leak detection Oil depots For product reception and at loading stations for wagons and ships Marine applications Loading and unloading of tankers Chemical industry Metering stations for non-corrosive liquids

Key points
> Minimum pressure drop Measurement tube of same diameter as the flanges No intrusive element > Low maintenance costs Totally static measurement system No need for filtering > Exceptional reliable measurements Three-channel redundant configuration for measurement validation > Easy installation Bi-directional measurement Reduced weight in a compact design

Ultrasonic flowmeter UFM III

Technical specifications
Model
Flow rate Application Connection - Flanges Pressure class Diameter Material Flanges, measurement tube, housing

UFM III
7 to 29 200 m3/h / 30 to 128 550 USGPM Single-product metering 150lbs RF (standard), 300lbs, 600lbs, 900lbs RF & RTJ (optional) 2 to 40 316L stainless steel (other materials available on request)

Operating conditions Operating pressure Liquid temperature Ambient temperature Viscosity Pressure loss (1 cSt, Qmax) Internal construction Ultrasound transmitters Measurement lines Metrological performance Measured parameter Volume accuracy Repeatability Installation Straight sections Protection class EX approval 0 to 63 bar +25 to +140C -40 to +70C 0,1 to 10 mPa.s < 0.1 bar Windows incorporated into wall of measurement tube 3 parallel channels Actual volume < 0.15% < 0.02% Inlet 10 DN / Outlet 5 DN IP 66, equivalent to NEMA 4/4X/6 to IEC 529 EEx d [ib] II C T6 and EEx d e [ib] II C T6

Measuring range - Weight and dimensions


Measuring range Nominal diameter Min. flowrate Max. flowrate (m3/h)
2 3 4 6 8 10 12 14 16 18 20 24 28 32 36 40 7 16 29 66 117 182 263 358 467 591 730 1051 1430 1868 2364 2919

Weight and dimensions a (mm)


290 330 380 440 600 640 710 770 830 900 950

Di (mm)
49,2 73 97,2 154,1 202,7 254,4 304,7 336,5 387,3 438,1 484

W (mm)
150 200 220 270 370 420 470 500 550 600 650

T (mm)
345 380 412 466 523 582 645 687 744 788 845

Weight (kg)
14 26 33 45 72 105 145 179 221 256 335

(m3/h)
73 164 292 657 1167 1824 2627 3575 4670 5910 7297 10507 14301 18679 23641 29196


Oil transport chain

Satam meters for oil transport chain

: Ideally suited

: Suitable subject to certain conditions

PD meter

Mass flowmeter

Turbine flowmeter

Ultrasonic flowmeter

Metering station for crude oil on pipeline

Loading and unloading station for crude oil tankers

Loading and unloading station for crude oil tanker wagons

Refining and intermediary storage

Road tanker loading station

Delivery of domestic fuel oil by road tanker

Aircraft refuelling


By liquid
Type of liquid
Premium grade fuel, gasoline Ethanol Diesel Fatty Acid Methyl Ester (FAME) Kerosene Bio-diesel E5...E85 Heavy fuel oil Bitumen Pitch LPG LNG Light crude oils Condensates Industrial oils

Flowmeter selection table


: Ideally suited

: Suitable subject to certain conditions

PD meter

Mass flowmeter

Turbine flowmeter

Ultrasonic flowmeter

By application
Type of application
Truck loading station Wagon loading/unloading station Tanker loading/unloading station Aircraft refuelling On-board metering for road tankers Preparation and metering of bio-fuels Metering for light crude oil on pipeline Metering for condensate on pipeline Multi-product metering on pipeline Product identification on multi-product pipeline Control of mixer flowrate for preparation of maritime fuel oils

PD meter

Mass flowmeter

Turbine flowmeter

Ultrasonic flowmeter

Worldwide Sales
Headquarters - Sales Department 5, rue des Chardonnerets BP 45 027 Tremblay 95 912 Roissy Charles de Gaulle Cedex FRANCE Tl. : +33 (0)1 49 90 77 00 Fax : +33 (0)1 49 90 77 99 E-mail : info@satam.eu Website : www.satam.eu Manufacturing facility 14, avenue de Verdun BP 129 14700 Falaise Cedex FRANCE Tl. : +33 (0)2 31 41 41 41 Fax : +33 (0)2 31 40 75 61

Headquarters Manufacturing facility Representative office Agents

As Tokheim regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.

BO42 - GB - RO - 02/09 - Marketing SATAM - Cration & Impression : DARMON IMPRESSIONS