You are on page 1of 34

' ' ' ' ' ' ' ' ' ' ' ' ' ' '

' '

Pipe Calculation Routines Copyright 2008 Daniel Wagner O. de Medeiros This file is part of DWSIM. DWSIM is it under the Free (at your free software: you can redistribute it and/or modify the terms of the GNU General Public License as published by Software Foundation, either version 3 of the License, or option) any later version.

DWSIM is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details. You should have received a copy of the GNU General Public License along with DWSIM. If not, see <http://www.gnu.org/licenses/>.

Imports Microsoft.MSDN.Samples.GraphicObjects Imports DWSIM.DWSIM.SimulationObjects.PropertyPackages.Auxiliary Imports DWSIM.DWSIM.Flowsheet.FlowSheetSolver Namespace DWSIM.SimulationObjects.UnitOps Public Enum FlowPackage Beggs_Brill Lockhart_Martinelli Petalas_Aziz End Enum <System.Serializable()> Public Class Pipe Inherits SimulationObjects_UnitOpBaseClass Protected m_profile As PipeProfile Protected m_thermalprofile As DWSIM.Editors.PipeEditor.ThermalEditorDefinitions Protected m_selectedflowpackage As FlowPackage = FlowPackage.Beggs_Brill Protected m_dp As Nullable(Of Double) Protected m_dt As Nullable(Of Double) Protected m_DQ As Nullable(Of Double) Protected m_tolP As Double = 10 Protected m_tolT As Double = 0.01 Protected m_maxItT As Integer = 25 Protected m_maxItP As Integer = 25 Protected m_flashP As Double = 1 Protected m_flashT As Double = 1 Protected m_includejteffect As Boolean = False Public Property IncludeJTEffect() As Boolean Get Return m_includejteffect End Get Set(ByVal value As Boolean) m_includejteffect = value End Set

End Property Public Property MaxPressureIterations() As Integer Get Return m_maxItP End Get Set(ByVal value As Integer) m_maxItP = value End Set End Property Public Property MaxTemperatureIterations() As Integer Get Return m_maxItT End Get Set(ByVal value As Integer) m_maxItT = value End Set End Property Public Property TriggerFlashP() As Double Get Return m_flashP End Get Set(ByVal value As Double) m_flashP = value End Set End Property Public Property TriggerFlashT() As Double Get Return m_flashT End Get Set(ByVal value As Double) m_flashT = value End Set End Property Public Property TolP() As Double Get Return m_tolP End Get Set(ByVal value As Double) m_tolP = value End Set End Property Public Property TolT() As Double Get Return m_tolT End Get Set(ByVal value As Double) m_tolT = value End Set End Property Public Property DeltaP() As Nullable(Of Double) Get Return m_dp End Get Set(ByVal value As Nullable(Of Double))

m_dp = value End Set End Property Public Property DeltaT() As Nullable(Of Double) Get Return m_dt End Get Set(ByVal value As Nullable(Of Double)) m_dt = value End Set End Property Public Property DeltaQ() As Nullable(Of Double) Get Return m_DQ End Get Set(ByVal value As Nullable(Of Double)) m_DQ = value End Set End Property Public Property SelectedFlowPackage() As FlowPackage Get Return Me.m_selectedflowpackage End Get Set(ByVal value As FlowPackage) Me.m_selectedflowpackage = value End Set End Property Public Property Profile() As PipeProfile Get Return m_profile End Get Set(ByVal value As PipeProfile) m_profile = value End Set End Property Public Property ThermalProfile() As DWSIM.Editors.PipeEditor.ThermalEditorDefinitions Get Return m_thermalprofile End Get Set(ByVal value As DWSIM.Editors.PipeEditor.ThermalEditorDefinitions) m_thermalprofile = value End Set End Property Public Sub New(ByVal nome As String, ByVal descricao As String) MyBase.CreateNew() Me.Profile = New PipeProfile Me.ThermalProfile = New DWSIM.Editors.PipeEditor.ThermalEditorDefinitions Me.m_ComponentName = nome Me.m_ComponentDescription = descricao Me.FillNodeItems() Me.QTFillNodeItems()

End Sub Public Overrides Function Calculate(Optional ByVal args As Object = Nothing) As Integer Dim form As Global.DWSIM.FormFlowsheet = My.Application.ActiveSimulation Dim objargs As New DWSIM.Outros.StatusChangeEventArgs If Not Me.GraphicObject.EnergyConnector.IsAttached Then 'Call function to calculate flowsheet With objargs .Calculado = False .Nome = Me.Nome .Tipo = TipoObjeto.Pipe End With CalculateFlowsheet(FlowSheet, objargs, Nothing) Throw New Exception(DWSIM.App.GetLocalString("Nohcorrentedeenergia3")) ElseIf Not Me.Profile.Status = PipeEditorStatus.OK Then 'Call function to calculate flowsheet With objargs .Calculado = False .Nome = Me.Nome .Tipo = TipoObjeto.Pipe End With CalculateFlowsheet(FlowSheet, objargs, Nothing) Throw New Exception(DWSIM.App.GetLocalString("Operfilhidrulicodatu")) ElseIf Not Me.GraphicObject.OutputConnectors(0).IsAttached Then 'Call function to calculate flowsheet With objargs .Calculado = False .Nome = Me.Nome .Tipo = TipoObjeto.Pipe End With CalculateFlowsheet(FlowSheet, objargs, Nothing) Throw New Exception(DWSIM.App.GetLocalString("Verifiqueasconexesdo")) ElseIf Not Me.GraphicObject.InputConnectors(0).IsAttached Then 'Call function to calculate flowsheet With objargs .Calculado = False .Nome = Me.Nome .Tipo = TipoObjeto.Pipe End With CalculateFlowsheet(FlowSheet, objargs, Nothing) Throw New Exception(DWSIM.App.GetLocalString("Verifiqueasconexesdo")) End If Dim fpp As DWSIM.FlowPackages.FPBaseClass Select Case Me.SelectedFlowPackage Case FlowPackage.Lockhart_Martinelli fpp = New DWSIM.FlowPackages.LockhartMartinelli Case FlowPackage.Petalas_Aziz fpp = New DWSIM.FlowPackages.PetalasAziz Case Else fpp = New DWSIM.FlowPackages.BeggsBrill End Select

Dim oms As DWSIM.SimulationObjects.Streams.MaterialStream = form.Collections.CLCS_MaterialStreamCollection(Me.GraphicObject.InputConnec tors(0).AttachedConnector.AttachedFrom.Name).Clone Me.PropertyPackage.CurrentMaterialStream = oms Dim Tin, Pin, Tout, Pout, Tout_ant, Pout_ant, Pout_ant2, Toutj, Text, Win, Qin, Qvin, Qlin, TinP, PinP, rho_l, rho_v, Cp_l, Cp_v, Cp_m, K_l, K_v, tens, Hin, Hout, HinP, _ fT, fT_ant, fT_ant2, fP, fP_ant, fP_ant2, z2, dzdT, hins, houts As Double Dim cntP, cntT As Integer If Me.ThermalProfile.Tipo = Editors.PipeEditor.ThermalProfileType.Definir_CGTC Then Text = Me.ThermalProfile.Temp_amb_definir Else Text = Me.ThermalProfile.Temp_amb_estimar End If 'Iterao para cada segmento Dim count As Integer = 0 'Calcular DP Dim Tpe, Ppe As Double Dim resv As Object Dim equilibrio As Object = Nothing Dim tmp As Object = Nothing Dim tipofluxo As String Dim first As Boolean = True Dim holdup, dpf, dph, dpt, DQ, U, A, eta As Double Dim nseg As Double Dim segmento As New PipeSection Dim results As New PipeResults Dim j As Integer = 0 With oms Tin = .Fases(0).SPMProperties.temperature.GetValueOrDefault Pin = .Fases(0).SPMProperties.pressure.GetValueOrDefault Win = .Fases(0).SPMProperties.massflow.GetValueOrDefault Qin = .Fases(0).SPMProperties.volumetric_flow.GetValueOrDefault Hin = .Fases(0).SPMProperties.enthalpy.GetValueOrDefault Hout = Hin Tout = Tin Pout = Pin TinP = Tin PinP = Pin HinP = Hin End With Dim tseg As Integer = 0 For Each segmento In Me.Profile.Sections.Values tseg += segmento.Incrementos Next For Each segmento In Me.Profile.Sections.Values Tout_ant2, _ eta_l, eta_v, w_v, w_l, w, z,

segmento.Resultados.Clear() If segmento.Tipo = DWSIM.App.GetLocalString("Tubulaosimples") Then j = 0 nseg = segmento.Incrementos With oms w = .Fases(0).SPMProperties.massflow.GetValueOrDefault hins = .Fases(0).SPMProperties.enthalpy.GetValueOrDefault Qlin = .Fases(3).SPMProperties.volumetric_flow.GetValueOrDefault + .Fases(4).SPMProperties.volumetric_flow.GetValueOrDefault + .Fases(5).SPMProperties.volumetric_flow.GetValueOrDefault + .Fases(6).SPMProperties.volumetric_flow.GetValueOrDefault rho_l = .Fases(1).SPMProperties.density.GetValueOrDefault eta_l = .Fases(1).SPMProperties.viscosity.GetValueOrDefault K_l = .Fases(1).SPMProperties.thermalConductivity.GetValueOrDefault Cp_l = .Fases(1).SPMProperties.heatCapacityCp.GetValueOrDefault tens = .Fases(0).TPMProperties.surfaceTension.GetValueOrDefault w_l = .Fases(1).SPMProperties.massflow.GetValueOrDefault Qvin = .Fases(2).SPMProperties.volumetric_flow.GetValueOrDefault rho_v = .Fases(2).SPMProperties.density.GetValueOrDefault eta_v = .Fases(2).SPMProperties.viscosity.GetValueOrDefault K_v = .Fases(2).SPMProperties.thermalConductivity.GetValueOrDefault Cp_v = .Fases(2).SPMProperties.heatCapacityCp.GetValueOrDefault w_v = .Fases(2).SPMProperties.massflow.GetValueOrDefault z = .Fases(2).SPMProperties.compressibilityFactor.GetValueOrDefault End With Do FlowSheet.WriteToLog(Me.GraphicObject.Tag & ": Calculating pipe segment #" & segmento.Indice & ", distance " & (j + 1) * segmento.Comprimento / segmento.Incrementos & "/" & segmento.Comprimento & "m", Color.DarkBlue, FormClasses.TipoAviso.Informacao) If Text > Tin Then Tout = Tin * 1.005 Else Tout = Tin / 1.005 End If

If Tin < Text And Tout > Text Then Tout = Text * 0.98 If Tin > Text And Tout < Text Then Tout = Text * 1.02 cntT = 0 'Loop externo (convergncia do Delta T) Do cntP = 0 'Loop interno (convergncia do Delta P) Do With segmento count = 0 With results .TemperaturaInicial = Tin .PressaoInicial = Pin .Energia_Inicial = Hin .Cpl = Cp_l .Cpv = Cp_v .Kl = K_l .Kv = K_v .RHOl = rho_l .RHOv = rho_v .Ql = Qlin .Qv = Qvin .MUl = eta_l .MUv = eta_v .Surft = tens .LiqRe = 4 / Math.PI * .RHOl * .Ql / (.MUl * segmento.DI * 0.0254) .VapRe = 4 / Math.PI * .RHOv * .Qv / (.MUv * segmento.DI * 0.0254) .LiqVel = .Ql / (Math.PI * (segmento.DI * 0.0254) ^ 2 / 4) .VapVel = .Qv / (Math.PI * (segmento.DI * 0.0254) ^ 2 / 4) End With resv = fpp.CalculateDeltaP(.DI * 0.0254, .Comprimento / .Incrementos, .Elevacao / .Incrementos, Me.rugosidade(.Material), Qvin * 24 * 3600, Qlin * 24 * 3600, eta_v * 1000, eta_l * 1000, rho_v, rho_l, tens) tipofluxo = resv(0) holdup = resv(1) dpf = resv(2) dph = resv(3) dpt = resv(4) End With Pout_ant2 = Pout_ant Pout_ant = Pout Pout = Pin - dpt fP_ant2 = fP_ant

fP_ant = fP fP = Pout - Pout_ant 'T = T - fi * (T - Tant2) / (fi - fi_ant2) If cntP > 3 Then Pout = Pout - fP * (Pout - Pout_ant2) / (fP - fP_ant2) End If cntP += 1 If Pout <= 0 Then Throw New Exception(DWSIM.App.GetLocalString("Pressonegativadentro")) End If If Double.IsNaN(Pout) Then Throw New Exception(DWSIM.App.GetLocalString("Erronoclculodapresso")) If cntP > Me.MaxPressureIterations Then Throw New Exception(DWSIM.App.GetLocalString("Ocalculadorexcedeuon")) CheckCalculatorStatus() Loop Until Math.Abs(fP) < Me.TolP With segmento Cp_m = holdup * Cp_l + (1 - holdup) * Cp_v Tout_ant2 = Tout_ant Tout_ant = Tout If Not Me.ThermalProfile.Tipo = Editors.PipeEditor.ThermalProfileType.Definir_Q Then If Me.ThermalProfile.Tipo = Editors.PipeEditor.ThermalProfileType.Definir_CGTC Then U = Me.ThermalProfile.CGTC_Definido A = Math.PI * (.DE * 0.0254) * .Comprimento / .Incrementos ElseIf Me.ThermalProfile.Tipo = Editors.PipeEditor.ThermalProfileType.Estimar_CGTC Then A = Math.PI * (.DE * 0.0254) * .Comprimento / .Incrementos U = Me.CALCULAR_CGTC(.Material, holdup, .Comprimento / .Incrementos, _ .DI * 0.0254, .DE * 0.0254, Me.rugosidade(.Material), Tpe, results.VapVel, results.LiqVel, _ results.Cpl, results.Cpv, results.Kl / 1000, results.Kv / 1000, _ results.MUl, results.MUv, results.RHOl, results.RHOv, _ Me.ThermalProfile.Incluir_cti, Me.ThermalProfile.Incluir_isolamento, _ Me.ThermalProfile.Incluir_paredes, Me.ThermalProfile.Incluir_cte) U = U End If If U <> 0 Then DQ = (Tout - Tin) / Math.Log((Text - Tin) / (Text - Tout)) * U / 1000 * A If Double.IsNaN(DQ) Then

DQ = 0 'Tout = Text Else Tout = DQ / (Win * Cp_m) + Tin End If If Not Double.TryParse(Tout, New Double) Or Double.IsNaN(Tout) Or Tout < 100 Or Tout > 1000 Then Throw New Exception(DWSIM.App.GetLocalString("Erroaocalculartemper")) End If Else Tout = Tin End If Else DQ = Me.ThermalProfile.Calor_trocado / tseg '/ 3600 Tout = DQ / (Win * Cp_m) + Tin A = Math.PI * (.DE * 0.0254) * .Comprimento / .Incrementos U = DQ / (A * (Tout - Tin)) * 1000 End If End With fT_ant2 = fT_ant fT_ant = fT fT = Tout - Tout_ant 'T = T - fi * (T - Tant2) / (fi - fi_ant2) If cntT > 3 Then Tout = Tout - fT * (Tout - Tout_ant2) / (fT - fT_ant2) End If cntT += 1 If Tout <= 0 Or Double.IsNaN(Tout) Then Throw New Exception(DWSIM.App.GetLocalString("Erronoclculodatemper")) End If If cntT > Me.MaxPressureIterations Then Throw New Exception(DWSIM.App.GetLocalString("Ocalculadorexcedeuon")) CheckCalculatorStatus() Loop Until Math.Abs(fT) < Me.TolT With Me.PropertyPackage If IncludeJTEffect Then Cp_m = (w_l * Cp_l + w_v * Cp_v) / w If oms.Fases(2).SPMProperties.molarfraction.GetValueOrDefault > 0 Then oms.Fases(0).SPMProperties.temperature = Tin - 2 .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Vapor)

z2 = oms.Fases(2).SPMProperties.compressibilityFactor.GetValueOrDefault dzdT = (z2 - z) / -2 Else dzdT = 0.0# End If If w_l <> 0.0# Then eta = 1 / (Cp_m * w) * (w_v / rho_v * (-Tin / z * dzdT) + w_l / rho_l) Else eta = 1 / (Cp_m * w) * (w_v / rho_v * (-Tin / z * dzdT)) End If Dim dh As Double = Cp_m * (Tout - Tin) eta * Cp_m * (Pout - Pin) houts = hins + dh / w 'Dim tmpr As Object = .DW_CalcEquilibrio_ISOL(PropertyPackages.FlashSpec.P, PropertyPackages.FlashSpec.H, Pout, houts, Tout) 'Toutj = tmpr(2) Toutj = Tout + eta * (Pin - Pout) / 1000 Tout = Toutj End If oms.Fases(0).SPMProperties.temperature = Tout oms.Fases(0).SPMProperties.pressure = Pout 'Calcular corrente de matria com Tpe e Ppe .DW_CalcEquilibrium(DWSIM.SimulationObjects.PropertyPackages.FlashSpec.T, DWSIM.SimulationObjects.PropertyPackages.FlashSpec.P) If oms.Fases(3).SPMProperties.molarfraction.GetValueOrDefault > 0 Then .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid1) Else .DW_ZerarPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid1) End If If oms.Fases(4).SPMProperties.molarfraction.GetValueOrDefault > 0 Then .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid2) Else .DW_ZerarPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid2) End If If oms.Fases(5).SPMProperties.molarfraction.GetValueOrDefault > 0 Then .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid3) Else .DW_ZerarPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid3) End If

If oms.Fases(6).SPMProperties.molarfraction.GetValueOrDefault > 0 Then .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Aqueous) Else .DW_ZerarPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Aqueous) End If If oms.Fases(7).SPMProperties.molarfraction.GetValueOrDefault > 0 Then .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Solid) Else .DW_ZerarPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Solid) End If If oms.Fases(2).SPMProperties.molarfraction.GetValueOrDefault > 0 Then .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Vapor) Else .DW_ZerarPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Vapor) End If If oms.Fases(2).SPMProperties.molarfraction.GetValueOrDefault >= 0 And oms.Fases(2).SPMProperties.molarfraction.GetValueOrDefault < 1 Then .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid) Else .DW_ZerarPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid) End If .DW_CalcCompMolarFlow(-1) .DW_CalcCompMassFlow(-1) .DW_CalcCompVolFlow(-1) .DW_CalcOverallProps() .DW_CalcTwoPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid, DWSIM.SimulationObjects.PropertyPackages.Fase.Vapor) .DW_CalcVazaoVolumetrica() .DW_CalcKvalue() End With With oms w = .Fases(0).SPMProperties.massflow.GetValueOrDefault hins = .Fases(0).SPMProperties.enthalpy.GetValueOrDefault Qlin = .Fases(3).SPMProperties.volumetric_flow.GetValueOrDefault + .Fases(4).SPMProperties.volumetric_flow.GetValueOrDefault + .Fases(5).SPMProperties.volumetric_flow.GetValueOrDefault + .Fases(6).SPMProperties.volumetric_flow.GetValueOrDefault rho_l = .Fases(1).SPMProperties.density.GetValueOrDefault eta_l = .Fases(1).SPMProperties.viscosity.GetValueOrDefault

K_l = .Fases(1).SPMProperties.thermalConductivity.GetValueOrDefault Cp_l = .Fases(1).SPMProperties.heatCapacityCp.GetValueOrDefault tens = .Fases(0).TPMProperties.surfaceTension.GetValueOrDefault w_l = .Fases(1).SPMProperties.massflow.GetValueOrDefault Qvin = .Fases(2).SPMProperties.volumetric_flow.GetValueOrDefault rho_v = .Fases(2).SPMProperties.density.GetValueOrDefault eta_v = .Fases(2).SPMProperties.viscosity.GetValueOrDefault K_v = .Fases(2).SPMProperties.thermalConductivity.GetValueOrDefault Cp_v = .Fases(2).SPMProperties.heatCapacityCp.GetValueOrDefault w_v = .Fases(2).SPMProperties.massflow.GetValueOrDefault z = .Fases(2).SPMProperties.compressibilityFactor.GetValueOrDefault End With With results .CalorTransferido = DQ .DpPorFriccao = dpf .DpPorHidrostatico = dph .HoldupDeLiquido = holdup .TipoFluxo = tipofluxo segmento.Resultados.Add(New PipeResults(.PressaoInicial, .TemperaturaInicial, .MUv, .MUl, .RHOv, .RHOl, .Cpv, .Cpl, .Kv, .Kl, .Qv, .Ql, .Surft, .DpPorFriccao, .DpPorHidrostatico, .HoldupDeLiquido, .TipoFluxo, .LiqRe, .VapRe, .LiqVel, .VapVel, .CalorTransferido, .Energia_Inicial, U)) End With Hout = Hin + DQ / Win Hin = Hout Tin = Tout Pin = Pout j += 1 Loop Until j = nseg Else 'CALCULAR DP PARA VALVULAS count = 0 If segmento.Indice = 1 Then With Me.PropertyPackage

Tpe = Tin + (Tout - Tin) / 2 Tpe = Tin + (Tout - Tin) / 2 Ppe = Pin + (Pout - Pin) / 2 oms.Fases(0).SPMProperties.temperature = Tpe oms.Fases(0).SPMProperties.pressure = Ppe 'Calcular corrente de matria com Tpe e Ppe .DW_CalcVazaoMolar() .DW_CalcEquilibrium(DWSIM.SimulationObjects.PropertyPackages.FlashSpec.T, DWSIM.SimulationObjects.PropertyPackages.FlashSpec.P) If oms.Fases(3).SPMProperties.molarfraction.GetValueOrDefault > 0 Then .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid1) Else .DW_ZerarPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid1) End If If oms.Fases(4).SPMProperties.molarfraction.GetValueOrDefault > 0 Then .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid2) Else .DW_ZerarPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid2) End If If oms.Fases(2).SPMProperties.molarfraction.GetValueOrDefault > 0 Then .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Vapor) Else .DW_ZerarPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Vapor) End If .DW_CalcLiqMixtureProps() .DW_CalcPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Mixture) .DW_CalcOverallProps() .DW_CalcTwoPhaseProps(DWSIM.SimulationObjects.PropertyPackages.Fase.Liquid, DWSIM.SimulationObjects.PropertyPackages.Fase.Vapor) .DW_CalcVazaoVolumetrica() End With With oms Qlin = .Fases(3).SPMProperties.volumetric_flow.GetValueOrDefault + .Fases(4).SPMProperties.volumetric_flow.GetValueOrDefault + .Fases(5).SPMProperties.volumetric_flow.GetValueOrDefault + .Fases(6).SPMProperties.volumetric_flow.GetValueOrDefault rho_l = .Fases(1).SPMProperties.density.GetValueOrDefault eta_l = .Fases(1).SPMProperties.viscosity.GetValueOrDefault K_l = .Fases(1).SPMProperties.thermalConductivity.GetValueOrDefault

Cp_l = .Fases(1).SPMProperties.heatCapacityCp.GetValueOrDefault tens = .Fases(0).TPMProperties.surfaceTension.GetValueOrDefault Qvin = .Fases(2).SPMProperties.volumetric_flow.GetValueOrDefault rho_v = .Fases(2).SPMProperties.density.GetValueOrDefault eta_v = .Fases(2).SPMProperties.viscosity.GetValueOrDefault K_v = .Fases(2).SPMProperties.thermalConductivity.GetValueOrDefault Cp_v = .Fases(2).SPMProperties.heatCapacityCp.GetValueOrDefault End With End If With segmento count = 0 With results .TemperaturaInicial = Tin .PressaoInicial = Pin .Energia_Inicial = Hin .Cpl = Cp_l .Cpv = Cp_v .Kl = K_l .Kv = K_v .RHOl = rho_l .RHOv = rho_v .Ql = Qlin .Qv = Qvin .MUl = eta_l .MUv = eta_v .Surft = tens .LiqRe = 4 / Math.PI * .RHOl * .Ql / (.MUl * 0.0254) .VapRe = 4 / Math.PI * .RHOv * .Qv / (.MUv * 0.0254) .LiqVel = .Ql / (Math.PI * (segmento.DI * 4) .VapVel = .Qv / (Math.PI * (segmento.DI * 4) End With results.TipoFluxo = "" resv = Me.Kfit(segmento.Tipo) If resv(1) Then dph = 0 dpf = resv(0) * (0.0101 * (.DI * 0.0254) ^ 0.2232) * (Qlin / (Qvin + Qlin) * rho_l + Qvin / (Qvin + Qlin) * rho_v) * (results.LiqVel.GetValueOrDefault + results.VapVel.GetValueOrDefault) ^ 2 / 2 Else dph = 0 dpf = resv(0) * (Qlin / (Qvin + Qlin) * rho_l + Qvin / (Qvin + Qlin) * rho_v) * (results.LiqVel.GetValueOrDefault + results.VapVel.GetValueOrDefault) ^ 2 / 2

segmento.DI * segmento.DI * 0.0254) ^ 2 / 0.0254) ^ 2 /

End If dpt = dpf 'If Not tmp Is Nothing Then ' tmp_ant = tmp 'Else ' tmp_ant = New Object() {form.Collections.CLCS_MaterialStreamCollection(Me.GraphicObject.InputConne ctors(0).AttachedConnector.AttachedFrom.Name).Fases(1).SPMProperties.molarf raction.GetValueOrDefault, 0} 'End If 'tmp = form.Options.SelectedPropertyPackage.DW_CalcEquilibrio_ISOL(PropertyPackage s.FlashSpec.P, PropertyPackages.FlashSpec.H, Pin - dpt, Hout, T2) Pout = Pin - dpt Tout = Tin DQ = 0 With results .CalorTransferido = DQ .DpPorFriccao = dpf .DpPorHidrostatico = dph .HoldupDeLiquido = holdup .TipoFluxo = DWSIM.App.GetLocalString("Turbulento") .TipoFluxoDescricao = "" segmento.Resultados.Add(New PipeResults(.PressaoInicial, .TemperaturaInicial, .MUv, .MUl, .RHOv, .RHOl, .Cpv, .Cpl, .Kv, .Kl, .Qv, .Ql, .Surft, .DpPorFriccao, .DpPorHidrostatico, .HoldupDeLiquido, .TipoFluxo, .LiqRe, .VapRe, .LiqVel, .VapVel, .CalorTransferido, .Energia_Inicial, U)) End With End With End If Next With results .TemperaturaInicial = Tout .PressaoInicial = Pout .Energia_Inicial = Hout .Cpl = Cp_l .Cpv = Cp_v .Kl = K_l .Kv = K_v .RHOl = rho_l .RHOv = rho_v .Ql = Qlin .Qv = Qvin .MUl = eta_l .MUv = eta_v .Surft = tens .LiqRe = 4 / Math.PI * .RHOl * .Ql / (.MUl * segmento.DI * 0.0254) .VapRe = 4 / Math.PI * .RHOv * .Qv / (.MUv * segmento.DI * 0.0254) .LiqVel = .Ql / (Math.PI * (segmento.DI * 0.0254) ^ 2 / 4)

.VapVel = .Qv / (Math.PI * (segmento.DI * 0.0254) ^ 2 / 4) .CalorTransferido = DQ .DpPorFriccao = dpf .DpPorHidrostatico = dph .HoldupDeLiquido = holdup .TipoFluxo = "-" .TipoFluxoDescricao = "" .HTC = U End With segmento.Resultados.Add(results) Me.DeltaP = -(PinP - Pout) Me.DeltaT = -(TinP - Tout) Me.DeltaQ = -(HinP - Hout) * Win 'Atribuir valores corrente de matria conectada jusante With form.Collections.CLCS_MaterialStreamCollection(Me.GraphicObject.OutputConne ctors(0).AttachedConnector.AttachedTo.Name) .Fases(0).SPMProperties.temperature = Tout .Fases(0).SPMProperties.pressure = Pout .Fases(0).SPMProperties.enthalpy = 0 Dim comp As DWSIM.ClassesBasicasTermodinamica.Substancia For Each comp In .Fases(0).Componentes.Values comp.FracaoMolar = form.Collections.CLCS_MaterialStreamCollection(Me.GraphicObject.InputConnec tors(0).AttachedConnector.AttachedFrom.Name).Fases(0).Componentes(comp.Nome ).FracaoMolar comp.FracaoMassica = form.Collections.CLCS_MaterialStreamCollection(Me.GraphicObject.InputConnec tors(0).AttachedConnector.AttachedFrom.Name).Fases(0).Componentes(comp.Nome ).FracaoMassica Next .Fases(0).SPMProperties.massflow = form.Collections.CLCS_MaterialStreamCollection(Me.GraphicObject.InputConnec tors(0).AttachedConnector.AttachedFrom.Name).Fases(0).SPMProperties.massflo w.GetValueOrDefault End With 'Corrente de energia - atualizar valor da potncia (kJ/s) With form.Collections.CLCS_EnergyStreamCollection(Me.GraphicObject.EnergyConnect or.AttachedConnector.AttachedTo.Name) .Energia = -Me.DeltaQ.Value .GraphicObject.Calculated = True End With 'Call function to calculate flowsheet With objargs .Calculado = True .Nome = Me.Nome .Tag = Me.GraphicObject.Tag .Tipo = TipoObjeto.Pipe End With segmento = Nothing results = Nothing form.CalculationQueue.Enqueue(objargs) End Function

Public Overrides Function DeCalculate() As Integer Dim form As Global.DWSIM.FormFlowsheet = My.Application.ActiveSimulation Dim segmento As New PipeSection For Each segmento In Me.Profile.Sections.Values segmento.Resultados.Clear() Next 'Zerar valores da corrente de matria conectada a jusante If Me.GraphicObject.OutputConnectors(0).IsAttached Then With form.Collections.CLCS_MaterialStreamCollection(Me.GraphicObject.OutputConne ctors(0).AttachedConnector.AttachedTo.Name) .Fases(0).SPMProperties.temperature = Nothing .Fases(0).SPMProperties.pressure = Nothing .Fases(0).SPMProperties.enthalpy = Nothing .Fases(0).SPMProperties.molarfraction = 1 .Fases(0).SPMProperties.massfraction = 1 Dim comp As DWSIM.ClassesBasicasTermodinamica.Substancia Dim i As Integer = 0 For Each comp In .Fases(0).Componentes.Values comp.FracaoMolar = 0 comp.FracaoMassica = 0 i += 1 Next .Fases(0).SPMProperties.massflow = Nothing .Fases(0).SPMProperties.molarflow = Nothing .GraphicObject.Calculated = False End With End If 'Corrente de energia - atualizar valor da potncia (kJ/s) If Me.GraphicObject.EnergyConnector.IsAttached Then With form.Collections.CLCS_EnergyStreamCollection(Me.GraphicObject.EnergyConnect or.AttachedConnector.AttachedTo.Name) .Energia = Nothing .GraphicObject.Calculated = False End With End If 'Call function to calculate flowsheet Dim objargs As New DWSIM.Outros.StatusChangeEventArgs With objargs .Calculado = False .Nome = Me.Nome .Tipo = TipoObjeto.Pipe End With segmento = Nothing form.CalculationQueue.Enqueue(objargs) End Function #Region " Funes"

Function Kfit(ByVal name2 As String) As Array Dim name As String = name2.Substring(name2.IndexOf("[") + 1, name2.Length - name2.IndexOf("[") - 2) Dim tmp(1) As Double 'Curva Normal 90;30,00;1; If name = 0 Then tmp(0) = 30 tmp(1) = 1 End If 'Curva Normal 45;16,00;1; If name = 1 Then tmp(0) = 16 tmp(1) = 1 End If 'Curva Normal 180;50,00;1; If name = 2 Then tmp(0) = 50 tmp(1) = 1 End If 'Vlvula Angular;55,00;1; If name = 3 Then tmp(0) = 55 tmp(1) = 1 End If 'Vlvula Borboleta (2" a 14");40,00;1; If name = 4 Then tmp(0) = 40 tmp(1) = 1 End If 'Vlvula Esfera;3,00;1; If name = 5 Then tmp(0) = 3 tmp(1) = 1 End If 'Vlvula Gaveta (Aberta);8,00;1; If name = 6 Then tmp(0) = 8 tmp(1) = 1 End If 'Vlvula Globo;340,00;1; If name = 7 Then tmp(0) = 340 tmp(1) = 1 End If 'Vlvula Lift-Check;600,00;1; If name = 8 Then tmp(0) = 600 tmp(1) = 1 End If 'Vlvula P (Poppet Disc);420,00;1; If name = 9 Then tmp(0) = 420 tmp(1) = 1 End If 'Vlvula Reteno de Portinhola;100,00;1; If name = 10 Then tmp(0) = 100 tmp(1) = 1

End If 'Vlvula Stop-Check (Globo);400,00;1; If name = 11 Then tmp(0) = 400 tmp(1) = 1 End If 'T (sada bilateral);20,00;1; If name = 12 Then tmp(0) = 20 tmp(1) = 1 End If 'T (sada de lado);60,00;1; If name = 13 Then tmp(0) = 60 tmp(1) = 1 End If 'Contrao Rpida d/D = 1/2;9,60;0; If name = 14 Then tmp(0) = 9.6 tmp(1) = 0 End If 'Contrao Rpida d/D = 1/4;96,00;0; If name = 15 Then tmp(0) = 96 tmp(1) = 0 End If 'Contrao Rpida d/D = 3/4;1,11;0; If name = 16 Then tmp(0) = 11 tmp(1) = 0 End If 'Entrada Borda;0,25;0; If name = 17 Then tmp(0) = 0.25 tmp(1) = 0 End If 'Entrada Normal;0,78;0; If name = 18 Then tmp(0) = 0.78 tmp(1) = 0 End If 'Expanso Rpida d/D = 1/2;9,00;0; If name = 19 Then tmp(0) = 9 tmp(1) = 0 End If 'Expanso Rpida d/D = 1/4;225,00;0; If name = 20 Then tmp(0) = 225 tmp(1) = 0 End If 'Expanso Rpida d/D = 3/4;0,60;0; If name = 21 Then tmp(0) = 0.6 tmp(1) = 0 End If 'Joelho em 90;60,00;1; If name = 22 Then tmp(0) = 60 tmp(1) = 1 End If

'Reduo Normal 2:1;5,67;0; If name = 23 Then tmp(0) = 5.67 tmp(1) = 0 End If 'Reduo Normal 4:3;0,65;0; If name = 24 Then tmp(0) = 0.65 tmp(1) = 0 End If 'Sada Borda;1,00;0; If name = 25 Then tmp(0) = 1 tmp(1) = 0 End If 'Sada Normal;1,00;0; If name = 26 Then tmp(0) = 1 tmp(1) = 0 End If Kfit = tmp End Function Function cond_isol(ByVal meio As Integer) As Double 'Asfalto 'Concreto 'Espuma de Poliuretano 'Espuma de PVC 'Fibra de vidro 'Plstico 'Vidro 'Definido pelo usurio cond_isol = 0 If meio = 0 Then cond_isol = 0.7 ElseIf meio = 1 Then cond_isol = 1 ElseIf meio = 2 Then cond_isol = 0.018 ElseIf meio = 3 Then cond_isol = 0.04 ElseIf meio = 4 Then cond_isol = 0.035 ElseIf meio = 5 Then cond_isol = 0.036

ElseIf meio = 6 Then cond_isol = 0.08 ElseIf meio = 7 Then cond_isol = 0 End If 'condutividade em W/(m.K) End Function Function rugosidade(ByVal material As String) As Double Dim epsilon As Double 'rugosidade em metros If material = DWSIM.App.GetLocalString("AoComum") Then epsilon = 0.0000457 If material epsilon = 0.000045 If material epsilon = 0.000259 If material epsilon = 0.000045 If material If material = DWSIM.App.GetLocalString("AoCarbono") Then = DWSIM.App.GetLocalString("FerroBottomido") Then = DWSIM.App.GetLocalString("AoInoxidvel") Then = "PVC" Then epsilon = 0.0000015 = "PVC+PFRV" Then epsilon = 0.0000015

rugosidade = epsilon End Function Function k_parede(ByVal material As String, ByVal T As Double) As Double Dim kp As Double 'condutividade trmica da parede do duto, em W/m.K If material = DWSIM.App.GetLocalString("AoComum") Then kp = 0.000000004 * T ^ 3 - 0.00002 * T ^ 2 + 0.021 * T + 33.743 If material = DWSIM.App.GetLocalString("AoCarbono") Then kp = 0.000000007 * T ^ 3 - 0.00002 * T ^ 2 - 0.0291 * T + 70.765 If material = DWSIM.App.GetLocalString("FerroBottomido") Then kp = -0.00000008 * T ^ 3 + 0.0002 * T ^ 2 - 0.211 * T + 127.99 If material = DWSIM.App.GetLocalString("AoInoxidvel") Then kp = 0.000000005 * T ^ 3 - 0.00001 * T ^ 2 + 0.024 * T ^ +8.6226 If material = "PVC" Then kp = 0.16 If material = "PVC+PFRV" Then kp = 0.16 k_parede = kp End Function Function k_terreno(ByVal terreno As Integer) As Double Dim kt = 0 If terreno = 2 Then kt = 1.1 'W/m.K

If terreno = 3 Then kt = 1.95 If terreno = 4 Then kt = 0.5 If terreno = 5 Then kt = 2.2 k_terreno = kt End Function Function CALCULAR_CGTC(ByVal materialparede As String, ByVal EL As Double, ByVal L As Double, _ ByVal Dint As Double, ByVal Dext As Double, ByVal rugosidade As Double, _ ByVal T As Double, ByVal vel_g As Double, ByVal vel_l As Double, _ ByVal Cpl As Double, ByVal Cpv As Double, ByVal kl As Double, ByVal kv As Double, _ ByVal mu_l As Double, ByVal mu_v As Double, ByVal rho_l As Double, _ ByVal rho_v As Double, ByVal hinterno As Boolean, ByVal isolamento As Boolean, _ ByVal parede As Boolean, ByVal hexterno As Boolean) If Double.IsNaN(rho_l) Then rho_l = 0.0# 'Calcular propriedades mdias Dim vel = vel_g + vel_l Dim mu = EL * mu_l + (1 - EL) * mu_v Dim rho = EL * rho_l + (1 - EL) * rho_v Dim Cp = EL * Cpl + (1 - EL) * Cpv Dim k = EL * kl + (1 - EL) * kv Dim Cpmist = Cp 'Clculo do coeficiente de transf. interno Dim U_int As Double If hinterno Then 'Calcular numero de Reynolds interno Dim Re_int = NRe(rho, vel, Dint, mu) Dim epsilon = Me.rugosidade(materialparede) Dim ffint = 0 If Re_int > 3250 Then Dim a1 = Math.Log(((epsilon / Dint) ^ 1.1096) / 2.8257 + (7.149 / Re_int) ^ 0.8961) / Math.Log(10.0#) Dim b1 = -2 * Math.Log((epsilon / Dint) / 3.7065 5.0452 * a1 / Re_int) / Math.Log(10.0#) ffint = (1 / b1) ^ 2 Else ffint = 64 / Re_int End If 'Calcular nmero de Prandtl interno Dim Pr_int = NPr(Cp, mu, k) 'Calcular coeficiente de transferncia de calor interno Dim h_int = hint_petukhov(k, Dint, ffint, Re_int, Pr_int) 'Calcular contribuio da parte interna U_int = h_int

End If 'Calcular contribuio da parede da tubulao Dim U_parede = 0 If parede = True Then U_parede = k_parede(materialparede, T) / (Math.Log(Dext / Dint) * Dint) If Dext = Dint Then U_parede = 0 End If 'Calcular contribuio do isolamento Dim U_isol = 0 Dim esp_isol = 0 If isolamento = True Then esp_isol = Me.m_thermalprofile.Espessura / 1000 U_isol = CDbl(Me.m_thermalprofile.Condtermica) / (Math.Log((Dext + esp_isol) / Dext) * Dext) End If 'Calcular coeficiente de transf. externo Dim U_ext = 0 If hexterno = True Then Dim mu2, k2, cp2, rho2 As Double If Me.m_thermalprofile.Meio <> 0 And Me.m_thermalprofile.Meio <> 1 Then Dim Zb = CDbl(Me.m_thermalprofile.Velocidade) Dim Rs = (Dext + esp_isol) / (2 * k_terreno(Me.m_thermalprofile.Meio)) * Math.Log((2 * Zb + (4 * Zb ^ 2 (Dext + esp_isol) ^ 2) ^ 0.5) / (Dext + esp_isol)) If Zb > 0 Then U_ext = 1 / Rs Else U_ext = 1000000.0 End If ElseIf Me.m_thermalprofile.Meio = 0 Then 'Calcular propriedades mdias vel = CDbl(Me.m_thermalprofile.Velocidade) Dim Tamb = Me.m_thermalprofile.Temp_amb_estimar Dim props = PropsAR(Tamb, 101325) mu2 = props(1) rho2 = props(0) cp2 = props(2) k2 = props(3) / 1000 'Calcular numero de Reynolds externo Dim Re_ext = NRe(rho2, vel, (Dext + esp_isol), mu2)

'Calcular nmero de Prandtl externo Dim Pr_ext = NPr(cp2, mu2, k2) 'Calcular coeficiente de transferncia de calor externo Dim h_ext = hext_holman(k2, (Dext + esp_isol), Re_ext, Pr_ext) 'Calcular contribuio da parte externa U_ext = h_ext * (Dext + esp_isol) / Dint ElseIf Me.m_thermalprofile.Meio = 1 Then 'Calcular propriedades mdias vel = CDbl(Me.m_thermalprofile.Velocidade) Dim Tamb = Me.m_thermalprofile.Temp_amb_estimar Dim props = PropsAGUA(Tamb, 101325) mu2 = props(1) rho2 = props(0) cp2 = props(2) k2 = props(3) / 1000 'Calcular numero de Reynolds externo Dim Re_ext = NRe(rho2, vel, (Dext + esp_isol), mu2) 'Calcular nmero de Prandtl externo Dim Pr_ext = NPr(cp2, mu2, k2) 'Calcular coeficiente de transferncia de calor externo Dim h_ext = hext_holman(k2, (Dext + esp_isol), Re_ext, Pr_ext) 'Calcular contribuio da parte externa U_ext = h_ext * (Dext + esp_isol) / Dint End If End If 'Calcular coeficiente global de transferncia de calor Dim _U As Double If U_int <> 0 Then _U = _U + 1 / U_int Else If hinterno = True Then _U = _U + 1.0E+30 End If End If If U_parede <> 0 Then _U = _U + 1 / U_parede Else If parede = True Then _U = _U + 1.0E+30 End If End If If U_isol <> 0 Then _U = _U + 1 / U_isol Else If isolamento = True Then _U = _U + 1.0E+30

End If End If If U_ext <> 0 Then _U = _U + 1 / U_ext Else If hexterno = True Then _U = _U + 1.0E+30 End If End If CALCULAR_CGTC = 1 / _U End Function Function NRe(ByVal rho As Double, ByVal v As Double, ByVal D As Double, ByVal mu As Double) As Double NRe = rho * v * D / mu End Function Function NPr(ByVal Cp As Double, ByVal mu As Double, ByVal k As Double) As Double NPr = Cp * mu / k End Function Function hext_holman(ByVal k As Double, ByVal Dext As Double, ByVal NRe As Double, ByVal NPr As Double) As Double hext_holman = k / Dext * 0.25 * NRe ^ 0.6 * NPr ^ 0.38 End Function Function hint_petukhov(ByVal k, ByVal D, ByVal f, ByVal NRe, ByVal NPr) hint_petukhov = k / D * (f / 8) * NRe * NPr / (1.07 + 12.7 * (f / 8) ^ 0.5 * (NPr ^ (2 / 3) - 1)) End Function Function PropsAR(ByVal Tamb As Double, ByVal Pamb As Double) Dim T = Tamb Dim rho = 314.56 * T ^ -0.9812 'viscosidade Dim mu = rho * (0.000001 * (0.00009 * T ^ 2 + 0.035 * T 2.9346)) 'capacidade calorfica Dim Cp = 0.000000000001 * T ^ 4 - 0.000000003 * T ^ 3 + 0.000002 * T ^ 2 - 0.0008 * T + 1.091 'condutividade trmica Dim k = -0.00000002 * T ^ 2 + 0.00009 * T + 0.0012 Dim tmp2(3)

tmp2(0) tmp2(1) tmp2(2) tmp2(3)

= = = =

rho mu Cp k

PropsAR = tmp2 End Function Protected m_iapws97 As New IAPWS_IF97 Function PropsAGUA(ByVal Tamb As Double, ByVal Pamb As Double) 'massa molar Dim mm = 18 Dim Tc = 647.3 Dim Pc = 217.6 * 101325 Dim Vc = 0.000001 * 56 Dim Zc = 0.229 Dim w = 0.344 Dim ZRa = 0.237 Dim R = 8.314 Dim P = Pamb Dim T = Tamb 'densidade Dim rho = Me.m_iapws97.densW(T, P / 100000) 'viscosidade Dim mu = Me.m_iapws97.viscW(T, P / 100000) 'capacidade calorfica Dim Cp = Me.m_iapws97.cpW(T, P / 100000) * 18 'condutividade trmica Dim k = Me.m_iapws97.thconW(T, P / 100000) Dim tmp2(3) tmp2(0) tmp2(1) tmp2(2) tmp2(3) = = = = rho mu Cp k

PropsAGUA = tmp2 End Function Function CALCT2(ByVal U As Double, ByVal DQ As Double, ByVal T1 As Double, ByVal Tamb As Double) As Double Dim T, Tinf, Tsup As Double Dim fT, fT_inf, nsub, delta_T As Double START_LOOP: If T1 > Tamb Then Tinf = Tamb Tsup = T1

Else Tinf = T1 Tsup = Tamb End If nsub = 5 delta_T = (Tsup - Tinf) / nsub Dim idx As Integer = 0 Do fT = Me.FT2(T1, Tinf, Tamb, U, DQ) Tinf = Tinf + delta_T fT_inf = Me.FT2(T1, Tinf, Tamb, U, DQ) idx += 1 If Not Double.TryParse(Tinf, New Double) Or Double.IsNaN(Tinf) Or Tinf < 100 Or idx > 100 Then Throw New Exception("Erro ao calcular temperatura") Loop Until fT * fT_inf < 0 Or Tinf > Tsup 'If Tinf > Tsup Then Throw New Exception(DWSIM.App.GetLocalString("Erroaocalculartemper")) Tsup = Tinf Tinf = Tinf - delta_T 'mtodo de Brent para encontrar Vc Dim aaa, bbb, ccc, ddd, eee, min11, min22, faa, fbb, fcc, ppp, qqq, rrr, sss, tol11, xmm As Double Dim ITMAX2 As Integer = 10000 Dim iter2 As Integer aaa = Tinf bbb = Tsup ccc = Tsup faa = Me.FT2(T1, Tinf, aaa, U, DQ) fbb = Me.FT2(T1, Tinf, bbb, U, DQ) fcc = fbb iter2 = 0 Do If (fbb > 0 And fcc > 0) Or (fbb < 0 And fcc < 0) Then ccc = aaa fcc = faa ddd = bbb - aaa eee = ddd End If If Math.Abs(fcc) < Math.Abs(fbb) Then aaa = bbb bbb = ccc ccc = aaa faa = fbb fbb = fcc fcc = faa End If tol11 = 0.0000001 xmm = 0.5 * (ccc - bbb) If (Math.Abs(xmm) <= tol11) Or (fbb = 0) Then GoTo Final3 If (Math.Abs(eee) >= tol11) And (Math.Abs(faa) > Math.Abs(fbb)) Then sss = fbb / faa If aaa = ccc Then

ppp = 2 * xmm * sss qqq = 1 - sss Else qqq = faa / fcc rrr = fbb / fcc ppp = sss * (2 * xmm * qqq * (qqq - rrr) - (bbb aaa) * (rrr - 1)) qqq = (qqq - 1) * (rrr - 1) * (sss - 1) End If If ppp > 0 Then qqq = -qqq ppp = Math.Abs(ppp) min11 = 3 * xmm * qqq - Math.Abs(tol11 * qqq) min22 = Math.Abs(eee * qqq) Dim tvar2 As Double If min11 < min22 Then tvar2 = min11 If min11 > min22 Then tvar2 = min22 If 2 * ppp < tvar2 Then eee = ddd ddd = ppp / qqq Else ddd = xmm eee = ddd End If Else ddd = xmm eee = ddd End If aaa = bbb faa = fbb If (Math.Abs(ddd) > tol11) Then bbb += ddd Else bbb += Math.Sign(xmm) * tol11 End If fbb = Me.FT2(T1, bbb, Tamb, U, DQ) iter2 += 1 Loop Until iter2 = ITMAX2 Final3: T = bbb Return T End Function Function FT2(ByVal T1 As Double, ByVal T2 As Double, ByVal Tamb As Double, ByVal U As Double, ByVal DQ As Double) As Double Dim f As Double If T1 < Tamb Then f = U * (T1 - T2) / Math.Log((Tamb - T2) / (Tamb - T1)) DQ Else f = U * (T2 - T1) / Math.Log((Tamb - T1) / (Tamb - T2)) DQ End If 'If Double.TryParse(f, New Double) Then ' Return f 'Else ' Return Tamb 'End If

Return f End Function #End Region Public Overloads Overrides Sub UpdatePropertyNodes(ByVal su As SistemasDeUnidades.Unidades, ByVal nf As String) Dim Conversor As New DWSIM.SistemasDeUnidades.Conversor If Me.NodeTableItems Is Nothing Then Me.NodeTableItems = New System.Collections.Generic.Dictionary(Of Integer, DWSIM.Outros.NodeItem) Me.FillNodeItems() End If For Each nti As Outros.NodeItem In Me.NodeTableItems.Values nti.Value = GetPropertyValue(nti.Text, FlowSheet.Options.SelectedUnitSystem) nti.Unit = GetPropertyUnit(nti.Text, FlowSheet.Options.SelectedUnitSystem) Next If Me.QTNodeTableItems Is Nothing Then Me.QTNodeTableItems = New System.Collections.Generic.Dictionary(Of Integer, DWSIM.Outros.NodeItem) Me.QTFillNodeItems() End If With Me.QTNodeTableItems Dim valor As String If Me.DeltaP.HasValue Then valor = Format(Conversor.ConverterDoSI(su.spmp_deltaP, Me.DeltaP), nf) Else valor = DWSIM.App.GetLocalString("NC") End If .Item(0).Value = valor .Item(0).Unit = su.spmp_deltaP If Me.DeltaT.HasValue Then valor = Format(Conversor.ConverterDoSI(su.spmp_deltaT, Me.DeltaT), nf) Else valor = DWSIM.App.GetLocalString("NC") End If .Item(1).Value = valor .Item(1).Unit = su.spmp_deltaT If Me.DeltaQ.HasValue Then valor = Format(Conversor.ConverterDoSI(su.spmp_heatflow, Me.DeltaQ), nf) Else valor = DWSIM.App.GetLocalString("NC") End If .Item(2).Value = valor .Item(2).Unit = su.spmp_heatflow End With

End Sub Public Overrides Sub QTFillNodeItems() With Me.QTNodeTableItems .Clear() .Add(0, New DWSIM.Outros.NodeItem("DP", "", "", 0, 0, "")) .Add(1, New DWSIM.Outros.NodeItem("DT", "", "", 1, 0, "")) .Add(2, New DWSIM.Outros.NodeItem("Q", "", "", 2, 0, "")) End With End Sub Public Overrides Sub PopulatePropertyGrid(ByRef pgrid As PropertyGridEx.PropertyGridEx, ByVal su As SistemasDeUnidades.Unidades) Dim Conversor As New DWSIM.SistemasDeUnidades.Conversor With pgrid .PropertySort = PropertySort.Categorized .ShowCustomProperties = True .Item.Clear() MyBase.PopulatePropertyGrid(pgrid, su) Dim ent, saida, energ As String If Me.GraphicObject.InputConnectors(0).IsAttached = True Then ent = Me.GraphicObject.InputConnectors(0).AttachedConnector.AttachedFrom.Tag Else ent = "" End If If Me.GraphicObject.OutputConnectors(0).IsAttached = True Then saida = Me.GraphicObject.OutputConnectors(0).AttachedConnector.AttachedTo.Tag Else saida = "" End If If Me.GraphicObject.EnergyConnector.IsAttached = True Then energ = Me.GraphicObject.EnergyConnector.AttachedConnector.AttachedTo.Tag Else energ = "" End If .Item.Add(DWSIM.App.GetLocalString("Correntedeentrada"), ent, False, DWSIM.App.GetLocalString("Conexes1"), "", True) With .Item(.Item.Count - 1) .DefaultValue = Nothing .CustomEditor = New DWSIM.Editors.Streams.UIInputMSSelector End With

.Item.Add(DWSIM.App.GetLocalString("Correntedesada"), saida, False, DWSIM.App.GetLocalString("Conexes1"), "", True) With .Item(.Item.Count - 1) .DefaultValue = Nothing .CustomEditor = New DWSIM.Editors.Streams.UIOutputMSSelector End With .Item.Add(DWSIM.App.GetLocalString("Correntedeenergia"), energ, False, DWSIM.App.GetLocalString("Conexes1"), "", True) With .Item(.Item.Count - 1) .DefaultValue = Nothing .CustomEditor = New DWSIM.Editors.Streams.UIOutputESSelector End With .Item.Add(DWSIM.App.GetLocalString("PerfilHidrulico"), Me, "Profile", False, DWSIM.App.GetLocalString("Perfis2"), DWSIM.App.GetLocalString("Cliquenobotocomretic2"), True) With .Item(.Item.Count - 1) .DefaultType = GetType(PipeProfile) .CustomEditor = New DWSIM.Editors.PipeEditor.UIPipeEditor .CustomTypeConverter = New DWSIM.Editors.PipeEditor.PipeEditorConverter End With .Item.Add(DWSIM.App.GetLocalString("Equaopfluxo"), Me, "SelectedFlowPackage", False, DWSIM.App.GetLocalString("Perfis2"), DWSIM.App.GetLocalString("Selecioneaequaoparac"), True) .Item.Add("Status", Me.Profile, "Status", True, DWSIM.App.GetLocalString("Perfis2"), "", True) .Item.Add(DWSIM.App.GetLocalString("PerfilTrmico"), Me, "ThermalProfile", False, DWSIM.App.GetLocalString("Perfis2"), DWSIM.App.GetLocalString("Cliquenobotocomretic3"), True) With .Item(.Item.Count - 1) .DefaultType = GetType(Global.DWSIM.DWSIM.Editors.PipeEditor.ThermalEditorDefinitions) .CustomEditor = New DWSIM.Editors.PipeEditor.UIThermalProfileEditor .CustomTypeConverter = New DWSIM.Editors.PipeEditor.ThermalProfileEditorConverter End With .Item.Add(DWSIM.App.GetLocalString("MximodeIteraesemP"), Me, "MaxPressureIterations", False, DWSIM.App.GetLocalString("Parmetros3"), "", True) .Item.Add(DWSIM.App.GetLocalString("MximodeIteraesemT"), Me, "MaxTemperatureIterations", False, DWSIM.App.GetLocalString("Parmetros3"), "", True) .Item.Add(DWSIM.App.GetLocalString("IncludeJTEffect"), Me, "IncludeJTEffect", False, DWSIM.App.GetLocalString("Parmetros3"), "", True) '.Item.Add(DWSIM.App.GetLocalString("Tolernciapreclculode") & " (%)", Me, "TriggerFlashP", False, DWSIM.App.GetLocalString("Parmetros3"), "", True) '.Item.Add(DWSIM.App.GetLocalString("Tolernciapreclculode2") & " (%)", Me, "TriggerFlashT", False, DWSIM.App.GetLocalString("Parmetros3"), "", True) .Item.Add(DWSIM.App.GetLocalString("Erromximodapresso") & " (Pa)", Me, "TolP", False, DWSIM.App.GetLocalString("Parmetros3"), "", True)

.Item.Add(DWSIM.App.GetLocalString("Erromximodatemperatu") & " (K)", Me, "TolT", False, DWSIM.App.GetLocalString("Parmetros3"), "", True) .Item.Add(FT("Delta P", su.spmp_deltaP), Format(Conversor.ConverterDoSI(su.spmp_deltaP, Me.DeltaP.GetValueOrDefault), FlowSheet.Options.NumberFormat), True, DWSIM.App.GetLocalString("Resultados4"), DWSIM.App.GetLocalString("Diferenadepressoentr"), True) With .Item(.Item.Count - 1) .DefaultValue = Nothing .DefaultType = GetType(Nullable(Of Double)) End With .Item.Add(FT(DWSIM.App.GetLocalString("DeltaT2"), su.spmp_deltaT), Format(Conversor.ConverterDoSI(su.spmp_deltaT, Me.DeltaT.GetValueOrDefault), FlowSheet.Options.NumberFormat), True, DWSIM.App.GetLocalString("Resultados4"), DWSIM.App.GetLocalString("Diferenadetemperatur"), True) With .Item(.Item.Count - 1) .DefaultValue = Nothing .DefaultType = GetType(Nullable(Of Double)) End With .Item.Add(FT(DWSIM.App.GetLocalString("Calortrocado"), su.spmp_heatflow), Format(Conversor.ConverterDoSI(su.spmp_heatflow, Me.DeltaQ.GetValueOrDefault), FlowSheet.Options.NumberFormat), True, DWSIM.App.GetLocalString("Resultados4"), DWSIM.App.GetLocalString("Quantidadedecalortro"), True) With .Item(.Item.Count - 1) .DefaultValue = Nothing .DefaultType = GetType(Nullable(Of Double)) End With .Item.Add(DWSIM.App.GetLocalString("Tabela"), Me, "Profile", False, DWSIM.App.GetLocalString("Resultados4"), DWSIM.App.GetLocalString("Cliquenobotocomretic4"), True) With .Item(.Item.Count - 1) .DefaultType = GetType(Global.DWSIM.DWSIM.Editors.PipeEditor.ThermalEditorDefinitions) .CustomEditor = New DWSIM.Editors.Results.UIFormTable End With .Item.Add(DWSIM.App.GetLocalString("Grfico"), Me, "Profile", False, DWSIM.App.GetLocalString("Resultados4"), DWSIM.App.GetLocalString("Cliquenobotocomretic5"), True) With .Item(.Item.Count - 1) .DefaultType = GetType(Global.DWSIM.DWSIM.Editors.PipeEditor.ThermalEditorDefinitions) .CustomEditor = New DWSIM.Editors.Results.UIFormGraph End With If Me.GraphicObject.Calculated = False Then .Item.Add(DWSIM.App.GetLocalString("Mensagemdeerro"), Me, "ErrorMessage", True, DWSIM.App.GetLocalString("Miscelnea5"), DWSIM.App.GetLocalString("Mensagemretornadaqua"), True) With .Item(.Item.Count - 1) .DefaultType = GetType(System.String) End With End If

If Me.IsSpecAttached = True Then .Item.Add(DWSIM.App.GetLocalString("ObjetoUtilizadopor"), FlowSheet.Collections.ObjectCollection(Me.AttachedSpecId).GraphicObject.Tag , True, DWSIM.App.GetLocalString("Miscelnea5"), "", True) .Item.Add(DWSIM.App.GetLocalString("Utilizadocomo"), Me.SpecVarType, True, DWSIM.App.GetLocalString("Miscelnea5"), "", True) End If If Not Me.Annotation Is Nothing Then .Item.Add(DWSIM.App.GetLocalString("Anotaes"), Me, "Annotation", False, DWSIM.App.GetLocalString("Outros"), DWSIM.App.GetLocalString("Cliquenobotocomretic"), True) With .Item(.Item.Count - 1) .IsBrowsable = False .CustomEditor = New DWSIM.Editors.Annotation.UIAnnotationEditor End With End If End With End Sub Public Overrides Function GetPropertyValue(ByVal prop As String, Optional ByVal su As SistemasDeUnidades.Unidades = Nothing) As Object If su Is Nothing Then su = New DWSIM.SistemasDeUnidades.UnidadesSI Dim cv As New DWSIM.SistemasDeUnidades.Conversor Dim value As Double = 0 Dim propidx As Integer = CInt(prop.Split("_")(2)) Select Case propidx Case 0 'PROP_PS_0 Pressure Drop value = cv.ConverterDoSI(su.spmp_deltaP, Me.DeltaP.GetValueOrDefault) Case 1 'PROP_PS_1 Temperature Drop value = cv.ConverterDoSI(su.spmp_deltaT, Me.DeltaT.GetValueOrDefault) Case 2 'PROP_PS_2 Heat Exchanged value = cv.ConverterDoSI(su.spmp_heatflow, Me.DeltaQ.GetValueOrDefault) End Select Return value End Function Public Overloads Overrides Function GetProperties(ByVal proptype As SimulationObjects_BaseClass.PropertyType) As String() Dim i As Integer = 0 Dim proplist As New ArrayList Select Case proptype Case PropertyType.RO For i = 0 To 2

proplist.Add("PROP_PS_" + CStr(i)) Next Case PropertyType.WR Case PropertyType.ALL For i = 0 To 2 proplist.Add("PROP_PS_" + CStr(i)) Next End Select Return proplist.ToArray(GetType(System.String)) proplist = Nothing End Function Public Overrides Function SetPropertyValue(ByVal prop As String, ByVal propval As Object, Optional ByVal su As DWSIM.SistemasDeUnidades.Unidades = Nothing) As Object Return 0 End Function Public Overrides Function GetPropertyUnit(ByVal prop As String, Optional ByVal su As SistemasDeUnidades.Unidades = Nothing) As Object If su Is Nothing Then su = New DWSIM.SistemasDeUnidades.UnidadesSI Dim value As String = "" Dim propidx As Integer = CInt(prop.Split("_")(2)) Select Case propidx Case 0 'PROP_PS_0 Pressure Drop value = su.spmp_deltaP Case 1 'PROP_PS_1 Temperature Drop value = su.spmp_deltaT Case 2 'PROP_PS_2 Heat Exchanged value = su.spmp_heatflow End Select Return value End Function End Class End Namespace