Technical Specification G Trans ACSR/GS Conductors

Ref Standard: IEC61089


S.no

Code
Name

Area

Aluminium

Steel

Diameter

UTS

Mass

DC
Resistance

Ampacity

16

18.7

No. of
Wire
6

25

29.2

2.30

2.30

6.91

9.13

100.9

1.1478

203

46.7

2.91

2.91

8.74

14.40

161.5

0.7174

274

mm2

Dia
mm
1.84

No.of
Wires
1

Dia
mm
1.84

mm

Kn

Kg/Km

Ohm/Km

Amperes

5.53

6.08

64.6

1.7394

155

63

73.5

3.66

3.66

11.0

21.63

254.4

0.4555

367

100

117.0

4.61

4.61

13.8

34.33

403.8

0.2869

493

125

132.0

18

2.97

2.97

14.9

29.17

397.9

0.2304

563

125

145.0

26

2.47

1.92

15.7

45.69

503.9

0.2310

571

160

169.0

18

3.36

3.36

16.8

36.18

509.3

0.1800

660

160

186.0

26

2.80

2.18

17.7

57.69

644.9

0.1805

669

10

200

211.0

18

3.76

3.76

18.8

44.22

636.7

0.1440

763

11

200

233.0

26

3.13

2.43

19.8

70.13

806.2

0.1444

774

12

250

275

22

3.80

2.11

21.6

68.72

880.6

0.1154

888

13

250

291

26

3.50

2.72

22.2

87.67

1007.7

0.1155

895

14

315

337

45

2.99

1.99

23.9

79.03

1039.6

0.0917

1027

15

315

366

26

3.93

3.05

24.9

106.83

1269.7

0.0917

1040

16

400

428

45

3.35

2.24

26.9

98.36

1320.1

0.0722

1199

17

400

452

54

3.07

3.07

27.6

123.04

1510.3

0.0723

1208

18

450

481

45

3.57

2.38

28.5

107.47

1485.2

0.0642

1294

19

450

508

54

3.26

3.26

29.3

138.42

1699.1

0.0643

1304

20

500

535

45

3.76

2.51

30.1

119.41

1650.2

0.0578

1387

21

500

565

54

3.43

3.43

30.9

153.80

1887.9

0.0578

1398

22

560

599

45

3.98

2.65

31.8

133.74

1848.2

0.0516

1493

23

560

631

54

3.63

19

2.18

32.7

172.59

2103.4

0.0516

1505

24

630

674

45

4.22

2.81

33.8

160.45

2079.2

0.0459

1612

25

630

710

54

3.85

19

2.31

34.7

191.77

2366.3

0.0459

1625

26

710

759

45

4.48

2.99

35.9

169.56

2343.2

0.0407

1744

27

710

800

54

4.09

19

2.45

36.8

216.12

2666.8

0.0407

1758

28

800

835

72

3.76

2.51

37.6

167.41

2480.2

0.0361

1879

29

800

867

84

3.48

3.48

38.3

205.33

2732.7

0.0362

1887

30

800

901

54

4.34

19

2.61

39.1

243.52

3004.9

0.0362

1899

31

900

939

72

3.99

2.66

39.9

188.33

2790.2

0.0321

2029

32

900

975

84

3.69

3.69

40.6

226.50

3074.2

0.0322

2037

33

1000

1043

72

4.21

2.80

42.1

209.25

3100.3

0.0289

2174

34

1120

1167

72

4.45

19

1.78

44.5

234.53

3454.9

0.0258

2341

35

1120

1211

84

4.12

19

2.47

45.3

283.17

3811.5

0.0258

2354

36

1250

1352

84

4.35

19

2.61

47.9

316.04

4253.9

0.0232

2526

37

1250

1303

72

4.70

19

1.88

47.0

161.75

3867.1

0.0231

2517

Note: All the parameters given in the above data sheet is for information purposes and VG will not be
held responsible for its accuracy
Ampacity Calculation Based on IEC 1597 Parameters; Wind Speed: 1 m/s; Intensity of Solar Radiation: 900 W/m2; Solar
Absorption Coefficient: 0.5; Emissivity: 0.6; Ambient temperature: 20 Operating Temperature for ACSR & AAAC is 85 and
90deg C respectively

www.vaibhavgroup.com

Technical Specification G Trans ACSR/GS Conductors


Ampacity Calculation Based on IEC 1597 Parameters; Wind Speed : 1 m/s; Intensity of Solar Radiation : 900 W/m2; Solar
Absorption Coefficient : 0.5; Emissivity : 0.6; Ambient temperature : 20

Technical Specification G Trans ACSR/GS Conductors


S.no

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3
4
5
1
2
3
4
5
6
7
8

Code Name

Area

Aluminium

mm2

No.
of
Wire

Dia
mm

Steel
No.of
Wires

Dia
mm

Diameter

UTS

Mass

DC
Resistance

Ampacity

mm

Kn

Kg/Km

Ohm/Km

Amperes

Conductors Used in Austria


35/6
40.1
6
2.70
1
2.70
8.1
12.37
138.7
0.8342
50/8
56.3
6
3.20
1
3.20
9.6
16.81
194.8
0.5939
70/12
81.3
26
1.85
7
1.44
11.7
26.27
282.2
0.4132
94/22
116.2
30
2.00
7
3.00
14.0
43.17
432.5
0.3067
95/15
109.7
26
2.15
7
1.67
13.6
34.93
380.6
0.3060
95/34
131.1
36
1.85
7
2.50
14.9
57.07
536.5
0.299
120/20
141.4
26
2.44
7
1.90
15.5
44.50
491.0
0.2375
120/42
160.4
36
2.05
7
2.75
16.5
68.79
653.9
0.2435
125/30
157.8
30
2.33
7
2.33
16.3
56.41
587.0
0.2260
150/25
173.1
26
2.70
7
2.10
17.1
53.67
600.8
0.194
150/53
202.4
36
2.30
7
3.10
18.5
84.29
827.1
0.1934
170/40
211.8
30
2.70
7
2.70
18.9
74.89
788.2
0.1683
185/30
213.6
26
3.00
7
2.33
19.0
65.27
741.0
0.1571
210/35
243.2
26
3.20
7
2.49
20.3
73.36
844.1
0.1381
210/50
261.5
30
3.00
7
3.00
21.0
92.46
973.1
0.1363
240/40
282.5
26
3.45
7
2.68
21.8
85.12
980.1
0.1188
240/80
320.2
36
2.90
19
2.35
23.4
134.37
1305.3
0.1218
257/60
316.5
30
3.30
7
3.30
23.1
108.20
1177.5
0.1126
300/50
353.7
26
3.86
7
3.00
24.4
105.09
1227.3
0.0949
340/110
450.0
78
2.36
19
2.70
27.7
183.73
1797.4
0.0848
380/50
431.2
54
3.00
7
3.00
27.0
121.30
1442.5
0.0758
450/40
488.2
48
3.45
7
2.68
28.7
119.05
1549.1
0.0644
560/50
611.2
48
3.86
7
3.00
32.2
146.28
1939.5
0.0515
680/85
764.5
54
4.00
19
2.40
36.0
206.56
2549.7
0.0426
Conductors Used in Belgium
147
147.1
30
2.25
7
2.25
15.8
71.33
547.0
0.2423
182
181.6
30
2.50
7
2.50
17.5
87.03
675.3
0.1963
228
227.8
30
2.80
7
2.80
19.6
109.17
847.1
0.1565
298
297.6
30
3.20
7
3.20
22.4
140.34
1106.4
0.1198
594
593.6
54
3.52
7
3.52
31.7
240.46
1984.3
0.0550
Conductors Used in Finland
Sparrow
39.5
6
2.68
1
2.68
8.04
12.18
136.6
0.8467
Raven
62.4
6
3.37
1
3.37
10.11
18.64
216.1
0.5355
Pigeon
99.3
6
4.25
1
4.25
12.75
29.22
343.6
0.3367
Suursavo
130.6
30
2.12
7
2.12
14.84
47.97
485.9
0.2729
Ostrich
176.9
26
2.73
7
2.12
17.28
54.78
613.6
0.1898
Duck
344.1
54
2.68
7
2.68
24.12
96.80
1151.2
0.0949
Finch
636.6
54
3.65
19
2.19
32.85
174.14
2123.0
0.0512
Savo
67.1
12
2.12
7
2.12
10.60
36.53
310.2
0.6817
Note: All the parameters given in the above data sheet is for information purposes and VG will not be
held responsible for its accuracy
Ampacity Calculation Based on IEC 1597 Parameters; Wind Speed: 1 m/s; Intensity of Solar Radiation: 900 W/m2; Solar
Absorption Coefficient: 0.5; Emissivity: 0.6; Ambient temperature: 20 Operating Temperature for ACSR & AAAC is 85 and
90deg C respectively

www.vaibhavgroup.com

248
309
392
479
476
494
561
564
584
639
655
707
733
797
810
878
885
917
1016
1116
1172
1295
1500
1706
559
640
741
881
1444
246
330
445
517
648
1012
1513
297

Technical Specification G Trans ACSR/GS Conductors


9
10
11
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Dotterel
Imatara
Kuopio

141.6
132.4
215.3

12
10
42

3.08
3.44
2.12

7
3.08
15.40
72.12
654.8
0.3230
7
2.68
14.92
60.35
565.1
0.3102
19
2.12
19.08
105.16
937.3
0.1955
Conductors used in France
Canna37.7
37.7
9
2.00
3
2.00
8.30
16.25
151.5
1.0187
Canna59.7
59.7
12
2.00
7
2.00
10.00
32.70
276.1
0.7660
Canna75.5
75.5
12
2.25
7
2.25
11.30
41.15
329.4
0.6052
Canna93.3
93.3
12
2.50
7
2.50
12.50
49.48
431.4
0.4902
Canna116.2
116.2
30
2.00
7
2.00
14.00
43.17
432.5
0.3067
Canna147.3
147.1
30
2.25
7
2.25
15.80
54.03
547.4
0.2423
Canna181.6
181.6
30
2.50
7
2.50
17.50
64.94
675.8
0.1963
Canna228
227.8
30
2.80
7
2.80
19.6
80.54
847.7
0.1565
Canna288
288.3
30
3.15
7
3.15
22.1
98.58
1072.8
0.1236
Conductors used in Germany
16/2.5
17.8
6
1.80
1
1.80
5.40
5.80
61.6
1.8769
25/4
27.8
6
2.25
1
2.25
6.75
8.95
96.3
1.2012
35/6
40.1
6
2.70
1
2.70
8.10
12.37
138.7
0.8342
44/32
75.6
14
2.00
7
2.40
11.20
44.24
369.3
0.6574
50/8
56.3
6
3.20
1
3.20
9.60
16.81
194.8
0.5939
50/30
81.0
12
2.33
7
2.33
11.7
42.98
374.7
0.5644
70/12
81.3
26
1.85
7
1.44
11.7
26.27
282.2
0.4132
95/15
109.7
26
2.15
7
1.67
13.6
34.93
380.6
0.3060
95/55
152.8
12
3.20
7
3.20
16.0
77.85
706.8
0.2992
105/75
181.2
14
3.10
19
2.25
17.5
105.82
885.3
0.2742
120/20
141.4
26
2.44
7
1.90
15.5
44.50
491.0
0.2376
120/70
193.4
12
3.60
7
3.60
18.0
97.92
894.5
0.2364
125/30
157.8
30
2.33
7
2.33
16.3
56.41
587.0
0.2260
150/25
173.1
26
2.70
7
2.10
17.1
53.67
600.8
0.194
170/40
211.8
30
2.70
7
2.70
18.9
74.89
788.2
0.1683
185/30
213.6
26
3.00
7
2.33
19.0
65.27
741.0
0.1571
210/35
243.2
26
3.20
7
2.49
20.3
73.36
844.1
0.1381
210/50
261.5
30
3.00
7
3.00
21.0
92.46
973.1
0.1363
230/30
260.8
24
3.50
7
2.33
21.0
72.13
870.9
0.1250
240/40
282.5
26
3.45
7
2.68
21.8
85.12
980.1
0.1188
265/35
297.7
24
3.74
7
2.49
22.4
81.04
994.4
0.1095
300/50
353.7
26
3.86
7
3.00
24.4
105.09
1227.3
0.0949
305/40
344.1
54
2.68
7
2.68
24.1
96.80
1151.2
0.0949
340/30
369.1
48
3.00
7
2.33
25.0
91.71
1171.2
0.0852
380/50
431.2
54
3.00
7
3.00
27.0
121.30
1442.5
0.0758
385/35
420.1
48
3.20
7
2.49
26.7
102.56
1333.6
0.0749
435/55
490.6
54
3.20
7
3.20
28.8
133.59
1641.3
0.0666
450/40
488.2
48
3.45
7
2.68
28.7
119.05
1549.1
0.0644
490/65
553.8
54
3.40
7
3.40
30.6
150.81
1852.9
0.0590
495/35
528.4
45
3.74
7
2.49
29.9
117.96
1632.6
0.0584
510/45
555.8
48
3.68
7
2.87
30.7
133.31
1765.3
0.0566
550/70
620.9
54
3.60
7
3.60
30.7
166.32
2077.2
0.0526
560/50
611.2
48
3.86
7
3.00
32.2
146.28
1939.5
0.0515
570/40
610.6
45
4.02
7
2.68
32.2
136.40
1887.1
0.0506
Note: All the parameters given in the above data sheet is for information purposes and VG will not be
held responsible for its accuracy
Ampacity Calculation Based on IEC 1597 Parameters; Wind Speed: 1 m/s; Intensity of Solar Radiation: 900 W/m2; Solar
Absorption Coefficient: 0.5; Emissivity: 0.6; Ambient temperature: 20 Operating Temperature for ACSR & AAAC is 85 and
90deg C respectively

www.vaibhavgroup.com

480
486
658
226
275
321
367
479
559
640
741
864
151
197
248
307
309
335
392
476
505
541
561
588
584
639
707
733
797
810
846
878
922
1016
1012
1080
1172
1175
1275
1295
1380
1377
1409
1463
1500
1513

Technical Specification G Trans ACSR/GS Conductors


35
36
1
2
3
4
5
6
7
8
9
10
11
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

650/45
680/85

698.8
764.5

45
54

4.30
4.00

7
2.87
34.4
156.18
2159.9
0.0442
19
2.40
36.0
206.56
2539.7
0.0426
Conductors Used in Spain
La 30
31.1
6
2.38
1
2.38
7.14
9.74
107.8
1.0736
La 56
54.6
6
3.15
1
3.15
9.45
16.29
188.8
0.6129
La 78
78.6
6
3.78
1
3.78
11.3
23.12
271.8
0.4256
La 110
116.2
30
2.00
7
2.00
14.0
43.17
432.5
0.3067
La 145
147.1
30
2.25
7
2.25
15.8
54.03
547.4
0.2423
La 180
181.6
30
2.50
7
2.50
17.50
64.94
675.8
0.1963
Hawk
281.1
26
3.44
7
2.68
21.8
84.89
976.2
0.1195
Gull
381.0
54
2.82
7
2.82
25.4
107.18
1274.6
0.0857
Condor
454.5
54
3.08
7
3.08
27.7
123.75
1520.5
0.0719
Cardinal
547.3
54
3.38
7
3.38
30.4
149.04
1831.1
0.0597
Finch
636.6
54
3.65
19
2.19
32.9
174.14
2123.0
0.0512
Conductors used in Switzerland
25.2
6
2.14
1
2.14
6.42
8.09
87.1
1.3279
34.9
6
2.52
1
2.52
7.56
10.77
120.8
0.9576
50.1
6
3.02
1
3.02
9.06
14.97
173.5
0.6668
69.7
6
3.56
1
3.56
10.7
20.50
241.1
0.4798
97.3
30
1.83
7
1.83
12.8
36.14
362.1
0.3663
119.8
30
2.03
7
2.03
14.2
43.98
445.6
0.2977
149.7
30
2.27
7
2.27
15.9
53.54
557.1
0.2381
184.5
30
2.52
7
2.52
17.6
65.24
686.6
0.1932
239.4
30
2.87
7
2.87
20.1
84.62
890.6
0.1489
261.5
30
3.00
7
3.00
21.0
92.46
973.1
0.1363
301.3
30
3.22
7
3.22
22.5
103.01
1121.1
0.1183
347.9
30
3.46
7
3.46
24.2
118.94
1294.4
0.1025
402.9
54
2.90
7
2.90
26.1
113.35
1348.0
0.0811
496.7
54
3.22
7
3.22
29.0
135.26
1661.9
0.0658
550.6
54
3.39
7
3.39
30.5
149.92
1842.0
0.0593
600.4
54
3.54
7
3.54
31.9
160.82
2008.6
0.0544
Conductors Used in United Kingdom
Mole
12.4
6
1.50
1
1.50
4.50
4.14
42.8
2.7027
Squirrel
24.5
6
2.11
1
2.11
6.33
7.87
84.7
1.3659
Gopher
30.6
6
2.36
1
2.36
7.08
9.58
106.0
1.0919
Weasel
36.9
6
2.59
1
2.59
7.77
11.38
127.6
0.9065
Fox
42.8
6
2.79
1
2.79
8.37
13.21
148.1
0.7812
Ferret
49.5
6
3.00
1
3.00
9.00
15.27
171.2
0.6757
Rabbit
61.7
6
3.35
1
3.35
10.1
18.42
213.5
0.5419
Mink
73.6
6
3.66
1
3.66
11.0
21.67
254.9
0.4540
Skunk
100.1
12
2.59
7
2.59
13.0
52.79
463.0
0.4568
Beaver
87.5
6
3.99
1
3.99
12.0
25.76
302.9
0.3820
Horse
116.2
12
2.79
7
2.79
14.0
61.26
537.3
0.3936
Racoon
116.2
6
4.09
1
4.09
12.3
27.06
318.3
0.3635
Otter
97.9
6
4.22
1
4.22
12.7
28.81
338.8
0.3415
Cat
111.3
6
4.50
1
4.50
13.5
32.76
385.3
0.3003
Hare
122.5
6
4.72
1
4.72
14.2
36.04
423.8
0.2730
Dog
118.5
6
4.72
7
1.57
14.2
32.65
394.0
0.2733
Note: All the parameters given in the above data sheet is for information purposes and VG will not be
held responsible for its accuracy
Ampacity Calculation Based on IEC 1597 Parameters; Wind Speed: 1 m/s; Intensity of Solar Radiation: 900 W/m2; Solar
Absorption Coefficient: 0.5; Emissivity: 0.6; Ambient temperature: 20 Operating Temperature for ACSR & AAAC is 85 and
90deg C respectively

www.vaibhavgroup.com

1691
1706
231
303
382
479
559
640
875
1082
1212
1369
1514
185
227
287
355
427
488
565
646
765
810
888
975
1121
1285
1375
1455
117
181
213
236
259
284
328
367
384
411
423
424
442
479
510
510

Technical Specification G Trans ACSR/GS Conductors


17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12

Coyote
Cougar
Tiger
Wolf
Dingo
Lynx
Caracal
Panther
Jaguar
Lion
Bear
Goat
Sheep
Antelope
Bison
Deer
Zebra
Elk
Camel
Moose

151.8
138.8
161.9
194.9
167.5
226.2
194.5
261.5
222.3
293.9
326.1
400.0
462.6
422.6
431.2
529.8
484.5
588.5
537.7
597.0

26
18
30
30
18
30
18
30
18
30
30
30
30
54
54
30
54
30
54
54

2.54
3.05
2.36
2.59
3.35
2.79
3.61
3.00
3.86
3.18
3.35
3.71
3.99
2.97
3.00
4.27
3.18
4.50
3.35
3.53

7
1.91
15.9
45.86
520.7
0.2192
1
3.05
15.3
29.74
418.8
0.2188
7
2.36
16.5
57.87
602.2
0.2202
7
2.59
18.1
68.91
725.3
0.1829
1
3.35
16.8
35.87
505.2
0.1814
7
2.79
19.5
79.97
841.6
0.1576
1
3.61
18.1
40.74
586.7
0.1562
7
3.00
21.0
92.46
973.1
0.1363
1
3.86
19.3
46.57
670.8
0.1366
7
3.18
22.3
100.47
1093.4
0.1213
7
3.35
23.5
111.50
1213.4
0.1093
7
3.71
26.0
135.13
1488.2
0.0891
7
3.99
27.9
156.30
1721.3
0.0771
7
2.97
26.7
118.88
1413.8
0.0773
7
3.00
27.0
121.30
1442.5
0.0758
7
4.27
29.9
179.00
1971.4
0.0673
7
3.18
28.6
131.92
1620.8
0.0674
7
4.50
31.5
198.80
2189.5
0.0606
7
3.35
30.2
146.40
1798.8
0.0608
7
3.53
31.8
159.92
1977.3
0.0547
Conductors used in Italy
42
49.5
6
3.00
7
3.00
9.0
15.27
171.2
0.6757
68
107.2
12
2.68
7
2.68
13.4
56.52
495.8
0.4266
128
148.5
26
2.50
7
1.95
15.9
46.79
516.0
0.2263
191
222.3
26
3.06
7
2.38
19.4
67.05
771.6
0.1510
212
261.5
30
3.00
7
3.00
21.0
92.46
973.1
0.1363
265
307.8
26
3.60
7
2.80
22.8
91.48
1068.0
0.1091
349
428.2
30
3.85
19
2.30
26.9
145.87
1585.7
0.0828
382
431.2
54
3.00
7
3.00
27.0
121.30
1442.5
0.0758
416
508.9
30
4.20
19
2.50
29.3
172.82
1881.8
0.0696
434
490.6
54
3.20
7
3.20
28.8
133.59
1641.3
0.0666
520
585.3
54
3.50
19
2.10
31.5
162.72
1952.1
0.0556
629
707.6
54
3.85
19
2.30
34.6
190.58
2356.6
0.0460
748
841.4
54
4.20
19
2.50
37.7
226.03
2799.3
0.0386
858
967.6
54
4.50
19
2.70
40.5
261.43
3226.9
0.0337
Conductors used in Sweden
Raven
62.4
6
3.37
1
3.37
10.1
18.64
216.1
0.5355
Pigeon
99.3
6
4.25
1
4.25
12.8
29.22
343.6
0.3367
Partridge
155.9
26
2.57
7
2.00
16.3
48.66
544.5
0.2141
Ibis
234.1
26
3.14
7
2.44
19.9
70.53
812.1
0.1434
Dove
328.5
26
3.72
7
2.89
23.6
97.56
1139.6
0.1022
Condor
454.5
54
3.08
7
3.08
27.7
123.75
1520.5
0.0719
Curlew
593.6
54
3.52
7
3.52
31.7
159.01
1986.0
0.0550
Skata
774.2
54
4.02
7
4.02
36.2
207.39
2590.2
0.0422
Falcon
908.7
54
4.36
19
2.62
39.3
245.77
3031.7
0.0358
Morkulla
592.0
42
4.13
7
2.31
31.7
123.47
1783.7
0.0513
Ripa
772.9
42
4.72
7
2.63
36.2
160.93
2327.5
0.0393
`Orre
908.8
42
5.12
7
2.83
39.2
188.55
2733.1
0.0334
Note: All the parameters given in the above data sheet is for information purposes and VG will not be
held responsible for its accuracy
Ampacity Calculation Based on IEC 1597 Parameters; Wind Speed: 1 m/s; Intensity of Solar Radiation: 900 W/m2; Solar
Absorption Coefficient: 0.5; Emissivity: 0.6; Ambient temperature: 20 Operating Temperature for ACSR & AAAC is 85 and
90deg C respectively

www.vaibhavgroup.com

588
582
594
669
657
737
724
810
789
874
936
1068
1173
1156
1172
1283
1264
1373
1354
1450
284
401
579
752
810
928
1120
1172
1254
1275
1434
1622
1817
1990
393
446
600
777
969
1212
1496
1717
1912
1496
1780
1978

Technical Specification G Trans ACSR/GS Conductors


13
14
15
16

Dotterel
Oden
Atle
Ymer

141.6
184.9
241.2
315.6

12
12
12
32

3.08
3.52
4.02
3.16

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

27
38
40
52
53
56
79
80
111
112
112
151
151
191
191
239
238
293
294
381
381
382
402
476
477
476
525
565
606
645
766
806

36.0
51.3
46.2
82.1
71.8
65.1
125.5
92.9
129.9
176.6
130.0
175.8
186.0
222.3
236.0
277.7
293.9
341.2
362.1
443.2
467.4
431.2
454.5
554.1
585.9
537.7
593.6
636.6
682.9
726.8
863.1
908.7

8
8
6
12
8
6
12
6
6
12
26
26
30
26
30
26
30
26
30
26
30
54
54
26
30
54
54
54
54
54
54
54

2.06
2.46
2.90
2.36
2.91
3.44
2.90
3.44
4.86
3.44
2.34
2.72
2.53
3.06
2.85
3.42
3.18
3.79
3.53
4.32
4.02
3.00
3.08
4.83
4.50
3.35
3.52
3.65
3.78
3.90
4.25
4.36

7
3.08
15.4
7
3.52
17.6
7
4.02
20.1
7
3.43
22.9
Conductors used in Norway
1
3.44
7.56
1
4.11
9.03
1
2.90
8.70
7
2.32
11.7
1
4.86
10.7
1
3.44
10.3
7
2.90
14.5
1
3.44
10.3
1
4.86
14.6
7
3.44
17.2
7
1.82
14.8
7
2.12
17.2
7
2.53
17.7
7
2.38
19.4
7
2.85
20.0
7
2.66
21.7
7
3.18
22.3
7
2.95
24.0
7
3.53
24.7
7
3.36
27.4
19
2.41
28.1
7
3.00
27.0
7
3.08
27.7
7
3.76
30.6
19
2.70
31.5
7
3.35
30.2
7
3.52
31.7
19
2.19
32.9
19
2.27
34.0
19
2.34
35.1
19
2.55
38.3
19
2.62
39.3

72.12
93.62
122.10
112.56

654.8
855.2
1154.4
1199.8

0.3230
0.2473
0.1896
0.1152

480
571
678
904

15.06
21.25
14.27
42.92
29.45
19.42
66.18
27.33
38.21
54.59
40.87
54.59
65.76
67.05
83.44
89.76
100.47
101.47
122.33
129.25
159.73
121.30
123.75
161.72
200.36
146.40
159.01
174.14
184.62
196.36
233.19
245.77

145.6
207.7
160.0
376.4
290.5
225.1
580.5
321.4
449.4
610.5
451.2
610.5
692.1
771.6
878.2
903.9
1093.4
1184.3
1347.3
1537.9
1733.6
1442.5
1520.5
1923.6
2173.3
1798.8
1986.0
2123.0
2278.0
2423.8
2878.3
3031.7

1.0776
0.7557
0.7231
0.5501
0.5400
0.5139
0.3643
0.3600
0.2575
0.1912
0.2583
0.1912
0.1916
0.1510
0.1510
0.1209
0.1213
0.0985
0.0984
0.0758
0.0760
0.0758
0.0719
0.0606
0.0606
0.0608
0.0550
0.0512
0.0477
0.0448
0.0377
0.0358

214
269
272
340
329
339
444
405
530
645
531
645
650
752
759
869
874
992
1001
1177
1184
1172
1212
1361
1373
1354
1444
1514
1585
1651
1849
1912

Note: All the parameters given in the above data sheet is for information purposes and VG will not be
held responsible for its accuracy
Ampacity Calculation Based on IEC 1597 Parameters; Wind Speed: 1 m/s; Intensity of Solar Radiation: 900 W/m2; Solar
Absorption Coefficient: 0.5; Emissivity: 0.6; Ambient temperature: 20 Operating Temperature for ACSR & AAAC is 85 and
90deg C respectively

www.vaibhavgroup.com